Agilent 81662A DFB Laser Agilent 81663A DFB Laser Agilent Fabry-Perot Lasers

Similar documents
Advanced Test Equipment Rentals ATEC (2832)

Agilent 81980/ 81940A, Agilent 81989/ 81949A, Agilent 81944A Compact Tunable Laser Sources

Agilent 81600B All-band Tunable Laser Source Technical Specifications December 2002

Advanced Test Equipment Rentals ATEC (2832)

Agilent 8703B Lightwave Component Analyzer Technical Specifications. 50 MHz to GHz modulation bandwidth

Agilent 83440B/C/D High-Speed Lightwave Converters

Agilent 86146B Optical Spectrum Analyzer Technical Specifications

Agilent 86030A 50 GHz Lightwave Component Analyzer Product Overview

Agilent 8644A-1 Phase noise test with the Agilent 8644A and 8665A Signal Generators Product Note

Agilent 83430A Lightwave Digital Source Product Overview

Agilent 8614xB Optical Spectrum Analyzer Family Technical Specifications

Agilent 8902A Measuring Receiver

Agilent 8902A Measuring Receiver Product Note

Agilent AN Balanced Circuit Measurement with an Impedance Analyzer/LCR Meter/Network Analyzer Application Note

Agilent E9300 Power Sensors E-Series Technical Overview

Agilent Technologies 8114A 100 V/2 A Programmable Pulse Generator

Agilent 8614xB Optical Spectrum Analyzer Family Technical Specifications

Phase Noise Measurement Personality for the Agilent ESA-E Series Spectrum Analyzers

Agilent E8247/E8257C PSG CW and Analog Signal Generators

Agilent 81980A, 81960A, 81940A, 81989A, 81949A, and 81950A Compact Tunable Laser Sources

Agilent 8761A/B Microwave Switches

Advanced Test Equipment Rentals ATEC (2832)

Agilent N1911A/N1912A P-Series Power Meters and N1921A/N1922A Wideband Power Sensors. Data sheet

Agilent 83711B and 83712B Synthesized CW Generators

Coherence control of the FOS-79800F. applications, Stimulated Brillouin Scattering. these reasons, controlling DFB source spectral

Agilent PSA Series Spectrum Analyzers Self-Guided Demonstration for Phase Noise Measurements

Agilent E8460A 256-Channel Reed Relay Multiplexer

Agilent 87415A, 87400A Microwave Amplifiers

Agilent PNA Series RF Network Analyzers

Agilent N4373B Lightwave Component Analyzer Testing advanced 40Gb/s components with highest relative and absolute accuracy

Advanced Test Equipment Rentals ATEC (2832)

Agilent 8491A/B, 8493A/B/C, 11581A, 11582A and 11583C Coaxial Attenuators dc to 26.5 GHz

How to Drive the Agilent Technologies Microwave Matrix and Transfer Switch via the E8483A Microwave Switch/Step Attenuator Driver.

Agilent dc Electronic Loads Models N3300A-N3307A

Agilent 970-Series Handheld Multimeters Data Sheet

Keysight Technologies 8160xx Family of Tunable Laser Sources. Data Sheet

Agilent E8267C PSG Vector Signal Generator

Obtaining Flat Test Port Power with the Agilent 8360 s User Flatness Correction Feature. Product Note

LM-QPSK-R. Lightwave Modulator for QPSK/ QAM. Features. Applications. Functional Diagram

PCI Express Receiver Design Validation Test with the Agilent 81134A Pulse Pattern Generator/ 81250A ParBERT. Product Note

Keysight Technologies 81980A, 81960A, 81940A, 81989A, 81949A, and 81950A Compact Tunable Laser Sources. Data Sheet

Agilent 71400C Lightwave Signal Analyzer Product Overview. Calibrated measurements of high-speed modulation, RIN, and laser linewidth

Base Station Installation and Maintenance

GM8036 LASER ANALYZER SWEEP SPECTRUM OPTICAL. Technical Specifications v1.01 March, 2011

Agilent Highly Accurate Amplifier ACLR and ACPR Testing with the Agilent N5182A MXG Vector Signal Generator. Application Note

IQS-2100/FLS-2100 OPTICAL LIGHT SOURCE. Telecom Test and Measurement

Agilent E4438C ESG Vector Signal Generator Differential I/Q outputs. Product Note

Characterizing High-Speed Oscilloscope Distortion A comparison of Agilent and Tektronix high-speed, real-time oscilloscopes

LIGHTWAVE, OPTICAL TEST EQUIPMENT

Model 1782 DWDM High Power CW Source Laser

LASER DIODE SOURCE FIBER OPTIC (SINGLE OR MULTI-WAVELENGTH)

Agilent E8267C/E8257C/E8247C PSG

Agilent 8360B Series Synthesized Swept Signal Generators 8360L Series Synthesized Swept CW Generators Data Sheet

Wavelength Calibration for the 8614X Series Optical Spectrum Analyzers. Product Note

Agilent PN 4395/96-1 How to Measure Noise Accurately Using the Agilent Combination Analyzers

Agilent Combining Network and Spectrum Analysis and IBASIC to Improve Device Characterization and Test Time

1782 DWDM High Power CW Source Laser

1550 nm Programmable Picosecond Laser, PM

56:/)'2 :+9: 3+'9;8+3+4:

ModBox - Spectral Broadening Unit

LASER DIODE SOURCE FIBER OPTIC (SINGLE OR MULTI-WAVELENGTH)

Keysight Technologies 8160xx Family of Tunable Laser Sources

HP 8509B Lightwave Polarization Analyzer. Product Overview. Optical polarization measurements of signal and components nm to 1600 nm

Agilent EPM Series Power Meters

Tunable Lasers. Figure 1, Photo of the Tunable Laser OEM Module, Model: TL-MC040TA101

RIO ORION Series 1550nm Low Phase Noise Narrow Linewidth Laser Module

System Cabling Errors and DC Voltage Measurement Errors in Digital Multimeters

Time-Domain Response of Agilent InfiniiMax Probes and Series Infiniium Oscilloscopes

Narrow Linewidth Micro- Integrable Tunable Laser Assembly u ITLA

OPTICAL MEASURING INSTRUMENTS. MS9710B 0.6 to 1.75 µm GPIB OPTICAL SPECTRUM ANALYZER

POLARIZATION EXTINCTION RATIO MEASUREMENT TEST SETFOR V-GROOVE ASSEMBLIES AND PM PATCHCORDS

Agilent PSA Series Spectrum Analyzers Noise Figure Measurements Personality

1782 DWDM High Power CW Source Laser

Xeston Technologies. XESTON 1550nm DWDM CW DFB Laser With PM Fiber. XQF935 Series Specification Datasheet (Preliminary)

Model 1772 DWDM High Power CW Source Laser

CISCO DWDM GBICS. Figure 1. Cisco DWDM GBICs. Main features of the Cisco DWDM GBICs:

Applications. Features. Data Sheet FRL15TCWx-D86-xxxxxA Apr Full Band Tunable DFB Laser Module

Product Note E5100A-2

Agilent 8560 E-Series Spectrum Analyzers

Agilent 8703A Lightwave Component Analyzer Technical Specifications

Picking the Optimal Oscilloscope for Serial Data Signal Integrity Validation and Debug

ModBox 1550 nm 44 Gb/s NRZ C, L bands ; 100 Mb/s - 44 Gb/s Reference Transmitter

DWDM CW DFB Laser Module

Agilent Technologies 3000 Series Oscilloscopes

OM2210 Coherent Receiver Calibration Source OM2210 Datasheet

OSICS Multifunction Platform

Agilent 8360B Series Synthesized Swept Signal Generators 8360L Series Synthesized Swept CW Generators

Agilent PSA Series Spectrum Analyzers Noise Figure Measurements Personality

Continuous-Wave (CW) Single-Frequency IR Laser. NPRO 125/126 Series

SHF Communication Technologies AG

Agilent U2000 Series USB Power Sensors. Data Sheet

Agilent Introduction to the Fixture Simulator Function of the ENA Series RF Network Analyzers: Network De-embedding/Embedding and Balanced Measurement

ModBox 850 nm 28 Gb/s NRZ 800 band ; 100 Mb/s - 28 Gb/s Reference Transmitter

Narrow Linewidth Full Band Tunable DFB Laser Module. Component Specifications

46 GBaud Multi-Format Optical Transmitter OM5110 Datasheet

Agilent 8766/7/8/9K Microwave Single-Pole Multi-Throw Switches

Using the Integrating Sphere in the Multiple Application Platform (MAP)

Genesis CX STM-Series

Agilent 8920A RF Communications Test Set Product Overview

Product Specification

Transcription:

Agilent 81662A DFB Laser Agilent 81663A DFB Laser Agilent Fabry-Perot Lasers Technical Specifications May 2003 The Agilent 81662A low power and 81663A high power DFB Laser Source modules are best suited for optical amplifier test and DWDM system test applications. The Agilent Fabry-Perot Laser Sources are available as single or dual wavelength sources, are insensitive to back reflections, and are stabilized for short and long term applications. The DFB and FP Laser Source modules are part of the flexible Agilent Lightwave Solution platform and have a future-proof design that allows for easy firmware upgrades.

Fabry-Perot source module specifications (Standard modules, 0dBm) Specifications apply to the end of a 2m long fiber cable (as specified under fiber type) with Diamond HMS-10/Agilent connectors attached. All specifications are valid for an attenuation setting of 0.0 db. All modules require straight output connectors. Agilent 81650A Agilent 81651A Agilent 81654A Type Fabry-Perot Laser Center wavelength [1] 1310 nm 15 nm 1550 nm 15 nm 1310/1550nm 15 nm Fiber type single-mode 9/125 m Spectral bandwidth (rms) [1] [2] <3.5 nm <4.5 nm <3.5nm/ 4.5nm Output power 0 dbm (1mW) CW power stability - short term (15 min.) <± 0.005 db typ. <±0.003 db with coherence control active - long term (24 h) - to back reflection (RL 14dB) typ. ± 0.03 db typ±0.003 db Dimensions (H x W x D) 75 mm x 32 mm x 335 mm (2.8 x 1.3 x 13.2 ) Weight 0.5 kg Recalibration period 2 years Operating temperature 0 C to 45 C Humidity Non condensing Warm-up time 60 minutes [3] [1] Center wavelength is shown on display [2] rms: root mean square [3] Warm-up time 20 min, if previously stored at the same temperature. [4] Controlled environment ( T = 1 C) Supplementary performance characteristics: Internal digital modulation mode: 270 Hz, 330 Hz, 1 khz, 2 khz and free selection 200 Hz to 10 khz. All output signals are pulse shaped, duty cycle 50%. Internal coherence control for linewidth broadening. Laser Safety Information All laser sources listed above are classified as Class 1 according to IEC 60825-1 (2001). All laser sources comply with 21 CFR 1040.10 except for deviations pursuant to Laser Notice No. 50, dated 2001-July-26. Output attenuation: The output power of all source modules can be attenuated from 0 db to 6 db in steps of 0.1 db. Page 2 of 6

Fabry-Perot source module specifications (High power modules, 13dBm) Specifications apply to the end of a 2m long fiber cable (as specified under fiber type) with Diamond HMS-10/Agilent connectors attached. All specifications are valid for an attenuation setting of 0.0 db. All modules require straight output connectors. Agilent 81655A Agilent 81656A Agilent 81657A Type Fabry-Perot Laser Center wavelength [1] 1310 nm 15 nm 1550 nm 15 nm 1310/1550 nm 15 nm Fiber type Standard single-mode 9 / 125 m Spectral bandwidth (rms ) [1] [2] <5.5 nm <7.5 nm <5.5 nm/7.5 nm Output power +13 dbm (20 mw) CW power stability - short term (15 min.) <±0.005 db typ <± 0.003 db with coherence control active - long term (24 h) - to back reflection (RL 14dB) typ. ±0.03 db typ ± 0.003 db Dimensions (H x W x D) 75 mm H x 32 mm W x 335 mm (2.8 x 1.3 x 13.2 ) Weight 0.5 kg Recalibration period 2 years Operating temperature 0 C to 45 C Humidity Noncondensing Warm-up time 60 min [3] [1] [2] [3] [4] Central wavelength is shown on display rms: root mean square Warm-up time 20 min, if previously stored at the same temperature. Controlled environment ( T = 1 C). Supplementary performance characteristics: Internal digital modulation mode: 270 Hz, 330 Hz, 1 khz, 2 khz and free selection 200 Hz to 10 khz. All output signals are pulse shaped, duty cycle 50 %. Internal coherence control for linewidth broadening Laser Safety Information All laser sources listed above are classified as Class 1M according to IEC 60825-1 (2001). All laser sources comply with 21 CFR 1040.10 except for deviations pursuant to Laser Notice No. 50, dated 2001-July-26. Output attenuation: The output power of all source modules can be attenuated from 0dB to 6dB in steps of 0.1 db. Page 3 of 6

DFB source module specifications Specifications apply to maximum power setting. Type [1] [2] Wavelength Tuning Range Display Resolution Repeatability [4] Stability (15min.) Stability (24h) Agilent 81662A For Peak Wavelengths see options CW DFB Laser with built-in isolator ITU Grid (100 GHz) typ. > ±500 pm 10 pm ±3 pm (typ. ±1 pm) ± 3 pm (typ ±1 pm) typ. ±5 pm Agilent 81663A For Peak Wavelengths see options CW DFB Laser with built-in isolator ITU Grid (100 GHz) typ. > ±850 pm [7] 10 pm ±5 pm (typ. ±2 pm) ± 5 pm (typ ±2 pm) typ. ±5 pm Fiber type Panda PMF 9 / 125 m Panda PMF 9 / 125 m Output Connector [6] Power Max. Output [5] CW Stability (15min) [4] CW Stability (24 h) Compatible to angled contact APC, ASC, DIN47256/4108 typ. > +10 dbm (10 mw) typ. ±0.005 db typ. ±0.03 db Compatible to angled contact APC, ASC, DIN47256/4108 typ. > +13 dbm (20 mw) typ. ±0.003 db typ. ±0.01 db Side Mode Suppression Ratio typ. 45 db typ. 50 db (SMSR) [5] Polarization Extinction Ratio (PER) typ. > 20 db typ. > 20 db Dimensions (H x W x D) 75 mm H x 32 mm W x 335 mm D 75 mm H x 32 mm W x 335 mm (2.8 x 1.3 x 13.2 ) D (2.8 x 1.3 x 13.2 ) Weight 0.5kg 0.5kg Recalibration Period 1 year 1 year Operating Temperature 15 C to 35 C 15 C to 35 C Warm-up time [3] 60 min 60 min ITU-grid wavelength is shown on display as default. Via GPIB tuning resolution < 10 pm. If previously stored at the same temperature 20 min. Controlled environment T = 1 C. At maximum power setting and default wavelength at the end of a 2 m SM patchcord. Connector interface not included. Valid for serial numbers starting with prefix DE417 and above. [1] [2] [3] [4] [5] [6] [7] Page 4 of 6

81662A/ 81663A option ITU Frequency [THz] Center Wavelengt h [nm] 81662A/ 81663A option ITU Frequency [THz] Center Wavelengt h [nm] 81662A/ 81663A option ITU Frequency [THz] Center Wavelengt h [nm] 309 311 313 315 317 319 321 323 325 327 329 331 333 335 337 339 341 343 345 347 349 351 353 355 357 359 361 363 365 367 369 371 373 196,00 195,90 195,80 195,70 195,60 195,50 195,40 195,30 195,20 195,10 195,00 194,90 194,80 194,70 194,60 194,50 194,40 194,30 194,20 194,10 194,00 193,90 193,80 193,70 193,60 193,50 193,40 193,30 193,20 193,10 193,00 192,90 192,80 1.529,55 1.530,33 1.531,12 1.531,90 1.532,68 1.533,47 1.534,25 1.535,04 1.535,82 1.536,61 1.537,40 1.538,19 1.538,98 1.539,77 1.540,56 1.541,35 1.542,14 1.542,94 1.543,73 1.544,53 1.545,32 1.546,12 1.546,92 1.547,72 1.548,51 1.549,32 1.550,12 1.550,92 1.551,72 1.552,52 1.553,33 1.554,13 1.554,94 375 377 379 381 383 385 387 389 391 393 395 397 399 401 403 405 407 409 411 413 415 417 419 421 423 425 427 429 431 433 435 437 439 192,70 192,60 192,50 192,40 192,30 192,20 192,10 192,00 191,90 191,80 191,70 191.60 191.50 191.40 191.30 191.20 191.10 191.00 190.90 190.80 190.70 190.60 190.50 190.40 190.30 190.20 190.10 190.00 189.90 189.80 189.70 189.60 189.50 1.555,75 1.556,55 1.557,36 1.558,17 1.558,98 1.559,79 1.560,61 1.561,42 1.562,23 1.563,05 1.563,86 1,564.68 1,565.50 1,566.31 1.567.13 1,567.95 1,568.77 1,569.59 1,570.42 1,571.24 1,572.06 1,572.89 1,573.71 1,574.54 1,575.37 1,576.20 1,577.03 1,577.86 1,578.69 1,579.52 1,580.35 1,581.18 1,582.02 441 443 445 447 449 451 453 455 457 459 461 463 465 467 469 471 473 475 477 479 481 483 485 487 489 491 493 495 497 499 501 503 505 189.40 189.30 189.20 189.10 189.00 188.90 188.80 188.70 188.60 188.50 188.40 188.30 188.20 188.10 188.00 187.90 187.80 187.70 187.60 187.50 187.40 187.30 187.20 187.10 187.00 186.90 186.80 186.70 186.60 186.50 186.40 186.30 186.20 1,582.85 1,583.69 1,584.53 1,585.36 1,586.20 1,587.04 1,587.88 1,588.73 1,589.57 1,590.41 1,591.26 1,592.10 1,592.95 1,593.79 1,594.64 1,595.49 1,596.34 1,597.19 1,598.04 1,598.89 1,599.75 1,600.60 1,601.46 1,602.31 1,603.17 1,604.03 1,604.88 1,605.74 1,606.60 1,607.47 1,608.33 1,609.19 1,610.06 Supplementary Performance Characteristics: Internal digital modulation mode: Free selection 200 Hz to 100 khz. All output signals are pulse shaped, duty cycle 50%. Internal coherence control for linewidth broadening. ON-switching with fast output power stabilization <20 s. Output power attenuation at default wavelength 6 db in steps of 0.1 db. Tuning speed over full range 30 s. Polarization maintaining fiber orientation: TE mode in slow axis, in line with connector key. Laser Safety Information The 81662A and 81663A DFB Laser Sources listed above are classified as Class 1M according to IEC 60825-1 (2001). All laser sources comply with 21 CFR 1040.10 except for deviations pursuant to Laser Notice No. 50, dated 2001- July-26. Page 5 of 6

Agilent Technologies Test and Measurement Support, Services, and Assistance Agilent Technologies aims to maximize the value you receive, while minimizing your risk and problems. We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need. Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully. Every instrument and system we sell has a global warranty. Support is available for at least five years beyond the production life of the product. Two concepts underlie Agilent's overall support policy: "Our Promise" and "Your Advantage." Our Promise Our Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality. When you are choosing new equipment, we will help you with product information, including realistic performance specifications and practical recommendations from experienced test engineers. When you use Agilent equipment, we can verify that it works properly, help with product operation, and provide basic measurement assistance for the use of specified capabilities, at no extra cost upon request. Many self-help tools are available. Your Advantage Your Advantage means that Agilent offers a wide range of additional expert test and measurement services, which you can purchase according to your unique technical and business needs. Solve problems efficiently and gain a competitive edge by contracting with us for calibration, extra-cost upgrades, out-of-warranty repairs, and on-site education and training, as well as design, system integration, project management, and other professional engineering services. Experienced Agilent engineers and technicians worldwide can help you maximize your productivity, optimize the return on investment of your Agilent instruments and systems, and obtain dependable measurement accuracy for the life of those products. By internet, phone, or fax, get assistance with all your test & measurement needs Online assistance: www.agilent.com/comms/lightwave Phone or Fax United States: (tel) 1 800 452 4844 For related literature, please visit: www.agilent.com/comms/dfb www.agilent.com/comms/fabry-perot Canada: (tel) 1 877 894 4414 (fax) (905) 282-4120 Europe: (tel) (31 20) 547 2323 (fax) (31 20) 547 2390 Japan: (tel) (81) 426 56 7832 (fax) (81) 426 56 7840 Latin America: (tel) (305) 269 7500 (fax) (305) 269 7599 Australia: (tel) 1 800 629 485 (fax) (61 3) 9210 5947 New Zealand: (tel) 0 800 738 378 (fax) 64 4 495 8950 Asia Pacific: (tel) (852) 3197 7777 (fax) (852) 2506 9284 Product specifications and descriptions in this document subject to change without notice. Copyright 2002-2003 Agilent Technologies May 22, 2003 5988-1570EN