Perkin Elmer Envision 2100 Multilabel Reader

Similar documents
Synergy NEO HTS Multi-Mode Microplate Reader

SpectraMax i3x Multi-Mode Detection Platform. Explore a wealth of applications in one future-ready system

Reference manual. EnVision. Software version 1.12

Microplate Reader EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES. Analytical Technologies Limited

Implementation of HTRF. technology on the Spark. multimode reader SENSITIVE, FAST AND RELIABLE MEASUREMENT OF HIGH-THROUGHPUT SCREENING ASSAYS

SP-8001 UV/Visible Spectrophotometer

Dual-FL. World's Fastest Fluorometer. Measure absorbance spectra and fluorescence simultaneously FLUORESCENCE

SpectraMax GEMINI EM. Dual-Scanning Microplate Spectrofluorometer Operator s Manual Orleans Drive Sunnyvale, California 94089

Lambda 1050 / 950 UV/Vis/NIR

Revision K 1/ B0001K

SpectraMax M3, M4, M5, and M5 e Multi-Mode Microplate Readers. User Guide

TECAN. i-control. Instructions for Use for. Document Part No.: Document Version No.: 1.6 Software Version No.: 1.

Akinori Mitani and Geoff Weiner BGGN 266 Spring 2013 Non-linear optics final report. Introduction and Background

Products - Microarray Scanners - Laser Scanners - InnoScan 900 Series and MAPIX Software

GCMS-3 GONIOSPECTROPHOTOMETER SYSTEM

Aqualog. Water Quality Measurements Made Easy FLUORESCENCE

3D light microscopy techniques

Thermo Scientific Varioskan Flash User Manual

T92+ UV-VIS SPECTROPHOTOMETER

ULS24 Frequently Asked Questions

Aqualog. Water Quality Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE

Aqualog. CDOM Measurements Made Easy PARTICLE CHARACTERIZATION ELEMENTAL ANALYSIS FLUORESCENCE GRATINGS & OEM SPECTROMETERS OPTICAL COMPONENTS RAMAN

Proudly serving laboratories worldwide since 1979 SPECIFICATIONS

Croma Enterprise Cromtech India

The only simultaneous absorbance and f uorescence system for water quality analysis! Aqualog

Operating Manual Revision B

TECAN. infinite 200. Instructions for Use for. Document Part No.: Document Revision No.: 1.4

Specifications Summary 1. Array Size (pixels) Pixel Size. Sensor Size. Pixel Well Depth (typical) 95,000 e - 89,000 e -

The new Konica Minolta DiMAGE Scan Dual IV film scanner

IPD3. Imaging Photon Detector APPLICATIONS KEY ATTRIBUTES

LaserBeam ProfilingSolutions. IRLaserBeam Profiler

Multi-channel imaging cytometry with a single detector

USB. Part No Wavelength range. Spectral bandwidth 5 nm 4 nm Optical system

Agilent Cary 7000 Universal Measurement Spectrophotometer (UMS)

FluorChem M MultiFluor System

Imagers- Molecular, Cell Standard Operating Procedures

Imaging Beyond the Basics: Optimizing Settings on the Leica SP8 Confocal

Confocal imaging on the Leica TCS SP8. 1) Turn the system on. 2) Use TCS user account. 3) Start LAS X software:

Applications of Steady-state Multichannel Spectroscopy in the Visible and NIR Spectral Region

Lab Junior Educational UV-VIS Spectrometer

BD LSRFortessa X-20. Special Order Product. Designed for limited space and boundless potential

Training Guide for Leica SP8 Confocal/Multiphoton Microscope

UV / VIS Spectrophotometer EMCLAB Instruments GmbH

Things to check before start-up.

SpectraPro 2150 Monochromators and Spectrographs

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

THE TUNABLE LASER LIGHT SOURCE C-WAVE. HÜBNER Photonics Coherence Matters.

INDIAN INSTITUTE OF TECHNOLOGY BOMBAY

DCS-120. Confocal Scanning FLIM Systems. Based on bh s Multidimensional Megapixel FLIM Technology

SpectraMax. M2/M2 e user guide A MULTI-DETECTION MICROPLATE READER WITH TWO-MODE CUVETTE PORT

MS260i 1/4 M IMAGING SPECTROGRAPHS

Thermo Scientific SPECTRONIC 200 Visible Spectrophotometer. The perfect. teaching instrument

Performance Comparison of Spectrometers Featuring On-Axis and Off-Axis Grating Rotation

Confocal Application Letter No. 13. Sequential Scan for Leica TCS NT/SP systems

CrystalPro is a computer-controlled microscope with top quality optics.

The Editor GT ink jet controller

In-Vivo IMAGING SYSTEMS. A complete line of high resolution optical & X-ray systems for pre-clinical imaging

LSM 710 Confocal Microscope Standard Operation Protocol

Non-Descanned FLIM Detection in Multiphoton Microscopes

1040 DPI High Resolution Full-page epassport Reader Regula 8703

Thermo Scientific SPECTRONIC 200 Education

Thermo Scientific SPECTRONIC 200 Visible Spectrophotometer. The perfect tool. for routine measurements

Machine Vision for the Life Sciences

Thermo Scientific SPECTRONIC 200

Nicolet Evolution 500. UV-Visible Spectrophotometer

Supporting Information

The Flash IIP Console is the heart of every FCR system. It s designed to maximize productivity in the busiest environments.

Advanced Test Equipment Rentals ATEC (2832)

High-sensitivity. optical molecular imaging and high-resolution digital X-ray. In-Vivo Imaging Systems

Optical Dispersion Analyzer

Cary 50 UV-Vis UV-VIS. SARIN sas di Leo Temin & C. VARIAN, INC. SPECTROPHOTOMETERS

Colony Imaging with powerful Analysis Software

THE ULTIMATE DOCUMENT EXAMINATION SYSTEM STATE-OF-THE-ART SPECTRAL ANALYSIS FORENSIC LABS SECURITY PRINTERS IMMIGRATION AUTHORITIES

Simplicity. Reliability. Performance. ProdigyPlus

Coherent Laser Measurement and Control Beam Diagnostics

CLV 480 Bar Code Scanner For near and far Dynamic focus control Advanced line

Bar code reader BCL 300i The multi-talent with extensive equipment options

The World s Most Trusted Name In Color Quality. HunterLab

Modular Circular Saccharimeters

PCS-150 / PCI-200 High Speed Boxcar Modules

Techniques for Suppressing Adverse Lighting to Improve Vision System Success. Nelson Bridwell Senior Vision Engineer Machine Vision Engineering LLC

VWR SPECTROPHOTOMETERS

In our previous lecture, we understood the vital parameters to be taken into consideration before data acquisition and scanning.

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs.

Improve asset protection and utilization

QAQC LAB 589 Rappahannnock Drive White Stone Va TEL (866)

IMAGELINK. The speed. digital scanners 2400dV plus 3000dV plus PowerFilm application software. The power of analog.

DATAVS2 series.

Achieving 100,000 : 1 contrast measurement

nanovea.com PROFILOMETERS 3D Non Contact Metrology

LSM 780 Confocal Microscope Standard Operation Protocol

BIO IMAGING. Choose your application of STELLA 2000 STELLA 3200 STELLA BIO Image. light source. light source. light source.

M4 TORNADO PLUS. Innovation with Integrity. Super Light Element Micro-XRF Spectrometer. Micro-XRF

Olympus LEXT OLS 4000 Confocal Laser Microscope

Retina 400 THE SIMPLE AND FLEXIBLE SOLUTION FOR HIGH DEFINITION RETINAL IMAGERY NON-MYDRIATIC RETINAL CAMERA C/D AUTO 60 H X 45 V LED. 2,2 mm.

picoemerald Tunable Two-Color ps Light Source Microscopy & Spectroscopy CARS SRS

ULS24 is built on 0.18um CMOS process at a world-leader specialty semiconductor foundry. LDO. 3.3v/1.8v 30mW. SPI uc (32-bit) 12 Mhz OSC

Colony Counting with powerful analysis software

Leica TCS SP8 Quick Start Guide

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs.

Transcription:

www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL 001.847.913.0777 for Refurbished & Certified Lab Equipment Perkin Elmer Envision 2100 Multilabel Reader Key features Modular design allowing: - Optimisation for specific applications - The possibility to upgrade later as needs change Fast measurement of all plate formats Supports all five main non-radiometric technologies with the facility for: - Kinetic measurements - Scanning of the well area Manual/Robotic loading and plate stackers available Windows NT/2000 software supporting: - Easy connectivity - Database storage of all results and protocols Barcoded filters and optical modules Easy to learn and to use Technologies Time-resolved fluorescence (TRF) (240-850 nm) Multiple time window TRF Dual emission measurements for Europium and Samarium labels (DELFIA technology) Dual emission measurements for LANCE assays Ratio measurements Fluorescence intensity (240-850 nm) Simultaneous dual emission measurements from the top of the plate or below it (two detector system) Ratio measurements Fluorescence polarization (FP) (240-850 nm) Simultaneous dual emission measurements (two detector system) Luminescence Simultaneous dual emission measurements (two detector system) Glow luminescence measurements Absorbance (240-850nm) Ratio measurements

General Description The Wallac 2100 EnVisionTM is the world s first multilabel plate reader developed to give optimized performance in every application. Based on a revolutionary modular design, it supports all the application areas that you and your colleagues work with, now or in the future. Modular design also means that when new types of assays come into use, or if your work changes, new modules can be added. Modularity stands for optimal performance with no compromise for each specific application. EnVision won t keep you waiting. The measurement time for a 1536-well plate is less than one minute (one flash/well). Applications EnVision is a multilabel reader for all major applications, including reporter gene assays cell applications genotyping enzyme assays signal transduction receptor ligand binding immunoassays quantification and possible other future assays. Specifications Fluorometry Fluorescein < 5 pm < 1 fmol/well 384 Performance Fluorescein < 5 pm < 0.25 fmol/well 1536 Performance Fluorescein < 20 pm < 0.15 fmol/well Fluorescence polarization Fluorescein 1 nm, SD < 3 mp 384 Performance Fluorescein 1 nm, SD < 3 mp 1536 Performance Fluorescein 1 nm, SD < 7 mp TR-Fluorometry

Europium 384 Performance Europium 1536 Performance Europium < 60 fm < 12 amol/well < 60 fm < 3 amol/well < 150 fm < 1 amol/well Luminometry ATP 75 pm Photometry Measuring range 0-3 OD Accuracy at 2 OD < 2 % or +/- 0.01 A 384 Performance Measuring range 0-3 OD Accuracy at 2 OD < 2 % or +/- 0.01 A 1536 Performance Measuring range 0-3 OD FP, Abs, FI, DELFIA 96 well plate Flashes time/plate 100 1 min 7 s 50 55 s 25 48 s 10 45 s 1 42 s 1, on the fly 31 s 384 well plate Flashes time/plate 100 2 min 43 s 50 1 min 56 s 25 1 min 37 s 10 1 min 20 s 1 1 min 7 s 1, on the fly 33 s 1536 well plate Flashes time/plate 100 9 min 32 s

50 6 min 14 s 25 4 min 33 s 10 3 min 33 s 1 2 min 58 s 1, on the fly 44 s Counting modes and features included EnVision counting modes are easily accessible. In the same protocol, even for the same well, you can freely use several different counting modes and labels. Kinetics Specific operation sequences can be defined easily. Enzyme assays, in particular, require kinetic measurements from the same well. Scanning Cell applications need several reading points in one well. Due to the heterogeneous spread of cells in a well it is important to scan the complete area of a cell culture well. The scanning function is also suitable for the reading of small membranes, chips and slides. Dual ratio measurements Certain labels requires dual excitation or emission readings. With EnVision protocols you can freely define different labels to match your specific assay needs. Simultaneous dual emission measurement with two emission detectors allows you to obtain the fastest possible results. Top and bottom reading Fluorescence readings (including FP and TRF) can be taken from the top or bottom. Top reading is the most efficient method when no lid is used because no plastic surface has to be penetrated. For adherent cells and lidded plates, below reading provides superior efficiency. It is a true epimode, in the sense that the both excitation and emission are directed to and from below. Multiple window time-resolved fluorescence The multiple window TRF option offers the possibility to record separate windows in one flash cycle. It is important to follow a change in the emission profile of a lanthanide chelate in energy transfer applications, especially when the actual energy transfer might be affected. Shaker The shaker accommodates the wide range of plates and applications for which EnVision is suited. Three modes are available; linear, orbital and double orbital. The duration, speed and amplitude of shaking can all be defined by the user.

Stacker Stackers represent a semi-automated plate loading option. Load and unload towers can take 20 or 50 plates at a time. With easy single-hand operation you place and remove the loaded stacker towers. Measurement is started with a single mouse-click. The plate stackers are robust towers, which are easy to lift into place and remove. Plates can be moved in both directions. Light sources EnVision employs a high stability, short arc flashlamp as a common light source in all measurements. For every type of assay the user can select the number of flashes used and thus the user can optimize measurement time. Fewer flashes results in a faster measurement time, all the way down to under one minute for a 1536 well plate. Optical system The unique measurement performance of Envision is a consequence of the instrument s special optical design. The optical system features Direct Double Optics. This means a full lens system without any light guides or fiber bundles on the top measurements. Optical filters A wide range of filters cover the wavelengths used in fluorometric and photometric applications. Additional filters are available upon request. All interference filters are pre-installed into the barcoded filter blocks which are easily installed in the instrument. Application-specific optical modules User interchangeable applicationspecific optical modules form a crucial part of the optical system. The optical modules include all application critical components;for example dichroic mirrors for specific labels. All application- specific optical modules are barcoded. For top reading, four optical modules can be in place. Any of the them can also be used for below reading. Detectors The photoluminescence detector is a red-sensitive temperature-stabilized photomultiplier tube to decrease background. For chemiluminescence and time-resolved fluorescence measurements the detectors are used in single photon counting mode. For fluorescence intensity and fluorescence polarization measurements the detectors are used as in gated analog mode with user adjustable gain, again to maximize performance. Two detectors increase speed of measurement which is highly advantageous in all dual emission measurements like FP (fluorescence polarization) and LANCE assays. Height sensor: Every time a plate is loaded the height is detected. This ensures that plate height will not damage the instrument.

Focus point adjustment: The focus point is adjustable. The measuring height can be defined as a parameter in your protocol. The focus point can be located at the very bottom or at the very top of the well or anywhere between. This is beneficial when measuring filters plates, cell layers, membranes etc. It also enables you to reduce sample volumes efficiently. Plate loading modes Manual reading (one plate at time) Stacker loading (up to 50 plates per load) Robotic integration Robotic integration When used with a robotic system, the EnVision reader is usually linked through OLE automation Active X/ COM interfaces. OLE and EnVision software provide the basis for seamless integration and instrument control. The robot and the counter work as a unit. Plate types All types of microplates with up to 1536 wells may be measured. Windows workstation software The EnVision user interface is easy to use and learn. Operating under Windows 2000 or Windows NT or future environments, it provides the level of reliability expected from 32-bit Windows software. True two-way communication with other instruments is easy to achieve due to the OLE interface and the Windows environment. The software includes a database for storage of all protocols and results. PC configurations Windows NT 4.0 SP6 or Windows 2000 Intel Pentium processor (>500 MHz) 128 MB or more memory 24-bt color display (1024 x 768) 10 GB free hard disc space CD-ROM drive Ethernet card Printer All Windows compatible printers are suitable. Connection to the PC is via parallel port. Test plate A test plate is supplied with every instrument. This includes multilabel solid samples covering all technologies and commonly used labels.

Physical dimensions Height: 580 mm Depth: 550 mm, with stacker: 700 mm Width: 420 mm Weight: 50 kg Power requirements Power consumption: 250 VA Mains voltage 110-120 V/220-240 V, 50/60 Hz Options EnVision grows with your needs. The instrument consists of a basic configuration to which you add the options needed for your laboratory. Options can be added later on when your demands change. Plate barcode The barcode reader allows you to load barcode labeled plates, which are identified by the barcode reader. Codabar, Code39, Interleaved 2 of 5, Code 128, UPC and EAN barcodes can be read. Ordering Information EnVisionTM 2100 Multilabel reader Measurement labels Fluorescence Intensity = FI Fluorescence Polarization = FP Time-resolved fluorescence = TRF Absorbance Luminescence Options High speed dual emission reading (two detector system) High throughput light source Stacker for automatic plate loading Magazines for 20 plates Magazines for 50 plates Below reading Below dual reading

Adjustment of measurement height Plate barcode reader, short side of the plate Plate barcode reader, long side of the plate computer www.ietltd.com Proudly serving laboratories worldwide since 1979 CALL 001.847.913.0777 for Refurbished & Certified Lab Equipment