Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Similar documents
Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Isolating Repeater Input Series 9163

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Isolators A3/1.

Binary Output Series 9175

Isolators A3/1. Vibration Transducer Supply Unit Series

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

Binary Output without Power Supply Series 9176

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

Isolators A3/1.

Isolators A3/1. Temperature Transmitter Field Circuit Non-Ex i Series

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

Fieldbus Isolating Repeater Series 9185/11

Analog Universal Module HART for Zone 2 Series 9468/33

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Digital Input Output Module for Zone 1 Series 9470/32

Temperature Input Module for Zone 1 Series 9482/32

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Two-channel safety barriers Series 9002

Two-channel safety barriers Series 9002

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Digital I/O Coupler (4-wire) Series 9413/21

Remote I/O. 74 Remote I/O. Remote I/O System

Single-Channel Safety Barriers Series 9001

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

Assembly. Front view. HiC2441. SL2 1b. Termination Board

Technical Information Barrier RB223

Inductive sensor slot-type SI2-K08-AP7

Temperature transmitter itemp PCP DIN rail TMT 121

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Temperature Transmitter itemp RTD DIN rail TMT 127

MACX MCR-EX-SL-RPSSI-I

Engineering Guideline. pac-carriers Type for Yokogawa Centum VP

itemp HART DIN rail TMT112

MACX MCR-EX-SL-RPSSI-I-UP(-SP)

0 2 1 â Ó. itemp HART TMT182. Technical Information

Assembly. Front view. Switch Power Rail

Assembly. Front view. Parametrization interface. Power Bus

ISOLATING SWITCHING AMPLIFIERS POWER SUPPLIES

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

SINEAX TI 807 Passive DC signal isolator

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

0 2 1 â Ó. itemp HART TMT182. Technical Information

Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)

â itemp Pt100 TMT127 Technical information Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring

Assembly. Front view. Switch Power Rail

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

Temperature transmitter itemp RTD DIN rail TMT 127

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Signal conditioner - MACX MCR-UI-UI-NC

Assembly. Front view. LED yellow: Relay output I. LED red: LB/SC channel I. LED yellow: Relay output II. LED red: LB/SC channel II

TR 104, TR 104-Ex Rail mounted Temperature Transmitters

TF 02 / TF 02-Ex. Head mounted temperature transmitters, FOUNDATION Fieldbus (H1), Pt 100 (RTD), thermocouples, 1 or 2 independent channels

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

D1072. SIL 2 Temperature Signal Converter, Duplicator, Adder/Subtractor DIN-Rail Models D1072S, D1072D. Front Panel and Features:

Technical Data. General specifications. Rated operating distance s n 3 mm

â Ó itemp TC TMT128 Technical information DIN rail mounted Temperature Transmitter for Thermocouples (TC)

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Resistance thermometer Model TR30, compact design

Head mounted Temperature Transmitter TF02/TF02-Ex

Temperature Measurement

Safety Instructions Nivotester FTC625, FTC325

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

A BB ME ASU R E ME NT & AN AL Y T ICS D AT A S H E ET. TTR200 Rail-mount temperature transmitter

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Rail mounted Temperature Transmitter TH102/TH102-Ex

TTH200 Head-mount temperature transmitter

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

MACX MCR-UI-UI-UP(-SP)(-NC)

Temperature Measurement Transmitters for mounting in sensor head

INSTRUCTION MANUAL. SIL 3 - SIL 2 Digital Output Loop/Bus Powered DIN-Rail Models D1040Q, D1041Q, D1042Q, D1043Q, D1040Q - D1041Q - D1042Q - D1043Q

Assembly. Front view. Power Rail

Technical Information RMA42

INSTRUCTION MANUAL. SIL 3 Switch/Proximity Detector Interface DIN-Rail Models D1034S, D1034D D1034S - D1034D

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

Temperature head transmitter itemp TC TMT 188

SINEAX B 811 Power Pack with additional Functions

JUMO dtrans T02 Programmable 4-wire Transmitter (Smart Transmitter)

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

FieldIT Temperature Transmitter, rail mounted TH102/TH102-Ex

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

Temperature Measurement

Temperature Measurement Transmitters for mounting in sensor head

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

KSR-Level sensor KSR-Schwimmer-Magnetschalter KSR Contact Protection Relays

PRetrans Table of contents

RMA42. Technical Information

SINEAX / EURAX 2I1 Passive DC signal isolator

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Coriolis Massflowmeter

Transcription:

Series 9160 > Intrinsically safe input [Ex ia] IIC > Galvanic isolation between input, output and power supply > For use up to SIL 2, special version up to SIL 3 (IEC 61508) > High accuracy www.stahl.de Series 9160 17852E00 Basic function: analogue input 0/4 ma... 20 ma, 1 and 2 channels. Transmitter supply units are used for intrinsically safe operation or 2- and 3-wires transmitters or for connection to intrinsically safe ma sources (4-wires transmitter). 2- and 3-wires transmitters are supplied with power via transmitter supply unit. In 2-wires transmitters the devices transmit HART communication signal bidirectionally. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone 0 1 2 20 21 22 Zone 0 1 2 20 21 22 Division 1 2 1 2 1 2 Installation in x x Installation in x x Installation in x x x Variants with UL certificate on request WebCode 9160A Isolators /1

Series 9160 Selection Table Output version (control) 0/4... 20 ma active / source with HART 0/4... 20 ma passive / sink with HART Note Chann els Input Output A Output B SIL LFD* Order number Art. no. Tech. data see page 1 0/4... 20 ma 0/4... 20 ma 2 no 9160/13-11-10s 214893 /3 3 yes 9160/13-11-13s 214897 /11 0/4... 20 ma 2 no 9160/19-11-10s 214901 /3 0/4... 20 ma 0/4... 20 ma 2 yes 9160/14-11-11s 214899 /7 High Power 2 0/4... 20 ma 0/4... 20 ma 0/4... 20 ma 2 no 9160/23-11-10s 214905 /3 1 0/4... 20 ma passive 2 no 9160/13-10-10s 214837 /14 passive 2 no 9160/19-10-10s 222093 /14 2 0/4... 20 ma passive passive 2 no 9160/23-10-10s 214903 /14 The order numbers listed in the table are for devices equipped with screw terminals. For devices equipped with springclamp terminals, replace the ending "s" for screw terminals with "k" for spring clamp terminals. * LFD - line fault diagnosis no - Device transmits line fault on the field side via the 4... 20 ma signal. Without LED / relay contact. yes - Device transmits line fault on the field side via the 4... 20 ma signal. With LED / relay contact. Further variants with line fault diagnosis are available on request. /2 Isolators

Series 9160/xx-11-10 Series 9160/xx-11-10 Explosion Protection Design 9160/xx-11-10 Global (IECEx) Gas, dust and mining IECEx BVS 08.0050X Ex na [ia Ga] IIC T4 Gc [Ex ia Da] IIIC [Ex ia Ma] I Europe (ATEX) Gas, dust and mining DMT 03 ATEX E 010 X E II 3 (1) G Ex na [ia Ga] IIC T4 Gc E II (1) D [Ex ia Da] IIIC E I (M1) [Ex ia Ma] I Certifications and certificates Certificates Ship approval Safety data Max. voltage U o Max. current I o Max. power P o Max. connectable capacitance C o IIC IIB / IIIC Max. connectable inductance L o IIC IIB / IIIC Internal capacitance C i Internal inductance L i Safety-related maximum voltage When connecting a current source Max. output voltage U o Max. connectable voltage U i Max. connectable current I i Internal capacitance C i Internal inductance L i Further parameters Installation Further information Functional safety (IEC 61508) Test report IECEx, ATEX, Brasil (INMETRO), Canada (cfm), Kazakhstan (TR), Russia (TR), Ukraine (TR), USA (FM), Belarus (TR) DNV GL 27 V 88 ma 576 mw 90 nf 705 nf 2.3 mh 17 mh 253 V 4.1 V 30 V 100 ma Max. SIL 2 Safe Failure Fraction SFF 85 % in Zone 2 and in the safe area see respective certificate and operating instructions Exida STAHL 10/02-01 R027 PFD AVG at T [Proof] T [Proof] PFD AVG 1 year 2.29 x 10-4 2 years 3.38 x 10-4 5 years 6.64 x 10-4 Further information For further information see safety test report. Isolators /3

Series 9160/xx-11-10 Design Electrical data Auxiliary power Nominal voltage U N Voltage range Residual ripple Nominal current at U N, 20 ma 9160/xx-11-10 24 V DC 18... 31.2 V ( 3.6 V SS 1 channel 75 ma 2 channels incls. 9160/19-xx-xx 131 ma Power consumption at U N, 20 ma 1 channel 1.8 W 2 channels incls. 9160/19-xx-xx 3.1 W Power dissipation at U N, R L = 250 Ω 1 channel 1.4 W 2 channels incls. 9160/19-xx-xx 2.3 W Polarity reversal protection yes Operation indication LED green "PWR" Undervoltage monitoring yes (no faulty module / output states) Galvanic separation Test voltages acc. to standard EN 60079-11 Ex i input to output 1.5 kv AC Ex i input to auxiliary power 1.5 kv AC Ex i input to error message 1.5 kv AC contact Ex i inputs interconnected 500 V AC acc. to standard EN 50178 Output to auxiliary power 350 V AC Outputs interconnected 350 V AC Error message contact to 350 V AC auxiliary power and outputs Ex i input Input signal 0/4... 20 ma with HART Functional range 0... 24 ma Max. input current for ma sources 50 ma Supply voltage for transmitter ) 16 V at 20 ma (for 2-wire) Residual ripple of supply voltage Open-circuit voltage ( 26 Short-circuit current ( 25 mv eff ( 35 ma Input resistance for ma sources ( 100 Ω Communication signal bi-directional HART transmission, 0.5... 10 khz Output Output signal 0/4... 20 ma with HART Load resistance R L 0... 600 Ω (terminal 1+ / 2- or 5+ / 6-) 0... 379 Ω (terminal 3+ / 2- or 4+ / 6-) (with internal 221 Ω resistor for HART) Residual ripple ( 40 μa eff Communication signal Response time (10... 90 %) Error detection Ex i input Behaviour of the output bi-directional HART transmission, 0.5... 10 khz (at 9160/19 only output 1) ( 100 μs (at 9160/19 output 2: ( 200 ms, typ. 100 ms) = Input signal /4 Isolators

Series 9160/xx-11-10 Electrical data Signal transmission Deviation ( 0,1 % Temperature effect Electromagnetic compatibility Accuracy, typical data expressed as % of calibrated span (20 ma) at U N, 23 C ( 0.05 % / 10 K Tested under the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21 Ambient conditions Ambient temperature Single device -20... +70 C Group assembly -20... +60 C The installation conditions affect the ambient temperature. Observe the "Cabinet installation guide". Storage temperature -40... +80 C Relative humidity (no condensation) ( 95 % Isolators /5

Series 9160/xx-11-10 Electrical connection Connection diagram 1 channel, output: active / source 9160/13-11-10. Division 1 Zone 0 / 1 Division 2 Zone 2 14163E02 1 channel, output: active / source 9160/19-11-10. Division 1 Zone 0 / 1 Division 2 Zone 2 14164E02 2 channels, outputs: active / source 9160/23-11-10. Division 1 Zone 0 / 1 Division 2 Zone 2 14165E02 /6 Isolators

Series 9160/xx-11-11 Series 9160/xx-11-11 Explosion Protection Global (IECEx) Gas, dust and mining IECEx BVS 08.0050X Ex na nc [ia Ga] IIC T4 Gc [Ex ia Da] IIIC [Ex ia Ma] I Europe (ATEX) Gas, dust and mining DMT 03 ATEX E 010 X E II 3 (1) G Ex na nc [ia Ga] IIC T4 Gc E II (1) D [Ex ia Da] IIIC E I (M1) [Ex ia Ma] I Certifications and certificates Certificates Ship approval IECEx, ATEX, Brasil (INMETRO), Canada (cfm), Kazakhstan (TR), Russia (TR), Ukraine (TR), USA (FM), Belarus (TR) DNV GL Safety data Design 9160/..-11-11 9160/14-11-11 Max. voltage U o 27 V 27 V Max. current I o 88 ma 112.5 ma Max. power P o 576 mw 731 mw Max. connectable capacitance C o IIC 90 nf 90 nf IIB / IIIC 705 nf 705 nf Max. connectable inductance L o IIC 2.3 mh 0.31 mh IIB / IIIC 17 mh 9.2 mh Internal capacitance C i Internal inductance L i Safety-related maximum 253 V 253 V voltage When connecting a current source Max. output voltage U o 4.1 V 4.1 V Max. connectable 30 V 30 V voltage U i Max. connectable 100 ma 100 ma current I i Internal capacitance C i Internal inductance L i Further parameters Installation in Zone 2, Div. 2 and in the safe area Further information see respective certificate and operating instructions Functional safety (IEC 61508) Test report Exida STAHL 10/02-01 R027 Max. SIL 2 Safe Failure Fraction SFF 85 % PFD AVG at T [Proof] T [Proof] PFD AVG 1 year 2.29 x 10-4 2 years 3.38 x 10-4 5 years 6.64 x 10-4 Further information For further information see safety test report. Isolators /7

Series 9160/xx-11-11 Electrical data Auxiliary power Design 9160/..-11-11 9160/14-11-11 Nominal voltage U N 24 V DC 24 V DC Voltage range 18... 31.2 V 18... 31.2 V Residual ripple ( 3.6 V SS ( 3.6 V SS Nominal current at U N, 20 ma 1 channel 88 ma 87 ma 2 channels incls. 9160/19-xx-xx 148 ma Power consumption at U N, 20 ma 1 channel 2.1 W 1.9 W 2 channels incls. 9160/19-xx-xx 3.4 W Power dissipation at U N, R L = 250 Ω 1 channel 1.7 W 1.6 W 2 channels incls. 9160/19-xx-xx 2.8 W Polarity reversal protection yes yes Operation indication LED green "PWR" LED green "PWR" Undervoltage monitoring yes (no faulty module / output states) Galvanic separation Test voltages acc. to standard EN 60079-11 Ex i input to output 1.5 kv AC Ex i input to auxiliary power 1.5 kv AC Ex i input to error message contact 1.5 kv AC Ex i inputs interconnected 500 V AC acc. to standard EN 50178 Output to auxiliary power 350 V AC Outputs interconnected 350 V AC Error message contact to auxiliary 350 V AC power and outputs Ex i input Design 9160/..-11-11 9160/14-11-11 Input signal 0/4... 20 ma with HART 0/4... 20 ma with HART Functional range 0... 24 ma 0... 24 ma Max. input current for ma sources 50 ma 50 ma Supply voltage for transmitter ) 16 V at 20 ma (for 2-wire) ) 17.5 V at 20 ma (for 2-, 3-wire) Residual ripple of supply voltage ( 25 mv eff ( 25 mv eff Open-circuit voltage ( 26 ( 26 Short-circuit current 35 ma 70 ma Input resistance for ma sources ( 100 Ω ( 100 Ω Communication signal bi-directional HART transmission, 0.5... 10 khz Output Output signal 0/4... 20 ma with HART Load resistance R L 0... 600 Ω (terminal 1+ / 2- or 5+ / 6-) 0... 379 Ω (terminal 3+ / 2- or 4+ / 6-) (with internal 221 Ω resistor for HART) Residual ripple ( 40 μa eff Communication signal Response time (10... 90 %) bi-directional HART transmission, 0.5... 10 khz (at 9160/19 only output 1) ( 100 μs (at 9160/19 output 2: ( 200 ms, typ. 100 ms) /8 Isolators

Series 9160/xx-11-11 Error detection Ex i input Wire breakage Short circuit Behaviour of the output Output current at I E = 0 Fault detection output Open-circuit Fault message Ex i input/output Settings (switch LF) Indication of faulty line Message faulty line and power supply failure Signal transmission < 3.6 ma > 20.5 ma = Input signal I A = 0 ma < 3.6 ma Deviation ( 0,1 % Temperature effect Electromagnetic compatibility activated / deactivated LED red "LF" per channel - Contact (30 V / 100 ma) closed to ground in case of fault -, floating contact (30 V / 100 ma) Accuracy, typical data expressed as % of calibrated span (20 ma) at U N, 23 C ( 0.05 % / 10 K Tested under the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21 Ambient conditions Ambient temperature Single device -20... +70 C Group assembly -20... +60 C The installation conditions affect the ambient temperature. Observe the "Cabinet installation guide". Storage temperature -40... +80 C Relative humidity (no condensation) ( 95 % Isolators /9

Series 9160/xx-11-11 Electrical connection Connection diagram 1 channel, output: active / source 9160/14-11-11. Division 1 Zone 0 / 1 Division 2 Zone 2 11563E02 1 channel, outputs 9160/19-11-11. Division 1 Zone 0 / 1 Division 2 Zone 2 06675E02 2 channels, outputs: active / source 9160/23-11-11. Division 1 Zone 0 / 1 Division 2 Zone 2 06471E02 /10 Isolators

Series 9160/13-11-13 Series 9160/13-11-13 Explosion Protection Design 9160/13-11-13 Global (IECEx) Gas, dust and mining IECEx BVS 08.0050X Ex na nc [ia Ga] IIC T4 Gc [Ex ia Da] IIIC [Ex ia Ma] I Europe (ATEX) Gas, dust and mining DMT 03 ATEX E 010 X E II 3 (1) G Ex na nc [ia Ga] IIC T4 Gc E II (1) D [Ex ia Da] IIIC E I (M1) [Ex ia Ma] I Certifications and certificates Certificates Ship approval Safety data Max. voltage U o Max. current I o Max. power P o Max. connectable capacitance C o IIC IIB / IIIC Max. connectable inductance L o IIC IIB / IIIC Internal capacitance C i Internal inductance L i Safety-related maximum voltage When connecting a current source Max. output voltage U o Max. connectable voltage U i Max. connectable current I i Internal capacitance C i Internal inductance L i Further parameters Installation Further information Functional safety (IEC 61508) Test report IECEx, ATEX, Brasil (INMETRO), Canada (cfm), Kazakhstan (TR), Russia (TR), Ukraine (TR), USA (FM), Belarus (TR) DNV GL 27 V 88 ma 576 mw 90 nf 705 nf 2.3 mh 17 mh 253 V 4.1 V 30 V 100 ma Max. SIL 3 Safe Failure Fraction SFF 95 % PFD AVG at T [Proof] Further information in Zone 2, Div. 2 and in the safe area see respective certificate and operating instructions Exida STAHL 10/02-01 R027 T [Proof] PFD AVG 1 year 5.96 x 10-5 2 years 8.76 x 10-5 5 years 1.72 x 10-4 For further information see safety test report. Isolators /11

Series 9160/13-11-13 Design 9160/13-11-13 Electrical data Auxiliary power Nominal voltage U N 24 V DC Voltage range 18... 31.2 V Residual ripple ( 3.6 V SS Nominal current at U N, 20 ma Power consumption at U N, 20 ma Power dissipation at U N, R L = 250 Ω 113 ma 2.7 W 2.2 W Polarity reversal protection yes Operation indication LED green "PWR" Undervoltage monitoring yes (no faulty module / output states) Galvanic separation Test voltages acc. to standard EN 60079-11 Ex i input to output 1.5 kv AC Ex i input to auxiliary power 1.5 kv AC Ex i input to error message 1.5 kv AC contact Ex i inputs interconnected 500 V AC acc. to standard EN 50178 Output to auxiliary power 350 V AC Outputs interconnected 350 V AC Error message contact to 350 V AC auxiliary power and outputs Ex i input Input signal 0/4... 20 ma with HART Functional range 0... 24 ma Max. input current for ma sources 50 ma Supply voltage for transmitter ) 16 V at 20 ma (for 2-wire) Residual ripple of supply voltage Open-circuit voltage ( 26 ( 25 mv eff Short-circuit current 35 ma Input resistance for ma sources ( 100 Ω Communication signal bi-directional HART transmission, 0.5... 10 khz Output Output signal 0/4... 20 ma with HART Load resistance R L 0... 600 Ω (terminal 1+ / 2-) 0... 379 Ω (terminal 3+ / 2-) (with internal 221 Ω resistor for HART) Residual ripple ( 40 μa eff Communication signal Response time (10... 90 %) Error detection Ex i input Wire breakage Short circuit Behaviour of the output Output current at I E = 0 Fault detection output Open-circuit bi-directional HART transmission, 0.5... 10 khz ( 100 μs < 3.6 ma > 20.5 ma = Input signal I A = 0 ma < 3.6 ma /12 Isolators

Series 9160/13-11-13 Electrical data Fault message Ex i input/output Settings (switch LF) Indication of faulty line Message faulty line and power supply failure Signal transmission Deviation ( 0,1 % Temperature effect Electromagnetic compatibility activated / deactivated LED red "LF" per channel - Contact (30 V / 100 ma) closed to ground in case of fault -, floating contact (30 V / 100 ma) Accuracy, typical data expressed as % of calibrated span (20 ma) at U N, 23 C ( 0.05 % / 10 K Tested under the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21 Ambient conditions Ambient temperature Single device -20... +70 C Group assembly -20... +60 C The installation conditions affect the ambient temperature. Observe the "Cabinet installation guide". Storage temperature -40... +80 C Relative humidity (no condensation) ( 95 % Electrical connection Connection diagram 1 channel, output: active / source 9160/13-11-13. Division 1 Zone 0 / 1 Division 2 Zone 2 07652E02 Isolators /13

Series 9160/xx-10-10 Series 9160/xx-10-10 Explosion Protection Design 9160/xx-10-10 Global (IECEx) Gas, dust and mining IECEx BVS 08.0050X Ex na nc [ia Ga] IIC T4 Gc [Ex ia Da] IIIC [Ex ia Ma] I Europe (ATEX) Gas, dust and mining DMT 03 ATEX E 010 X E II 3 (1) G Ex na nc [ia Ga] IIC T4 Gc E II (1) D [Ex ia Da] IIIC E I (M1) [Ex ia Ma] I Certifications and certificates Certificates Ship approval Safety data Max. voltage U o Max. current I o Max. power P o IECEx, ATEX, Brasil (INMETRO), Canada (cfm), Kazakhstan (TR), Russia (TR), Ukraine (TR), USA (FM), Belarus (TR) DNV GL 27 V 88 ma 576 mw Max. connectable capacitance C o IIC IIB / IIIC 90 nf 705 nf Max. connectable inductance L o IIC 2.3 mh IIB / IIIC 17 mh Internal capacitance C i Internal inductance L i Safety-related maximum voltage 253 V When connecting a current source Max. output voltage U o 4.1 V Max. connectable voltage U i 30 V Max. connectable current I i 100 ma Internal capacitance C i Internal inductance L i Further parameters Installation in Zone 2, Div. 2 and in the safe area Further information see respective certificate and operating instructions Functional safety (IEC 61508) Test report Exida STAHL 10/02-01 R027 Max. SIL 2 Safe Failure Fraction SFF 85 % PFD AVG at T [Proof] T [Proof] PFD AVG 1 year 2.29 x 10-4 2 years 3.38 x 10-4 5 years 6.64 x 10-4 Further information For further information see safety test report. /14 Isolators

Series 9160/xx-10-10 Design Electrical data Auxiliary power Nominal voltage U N Voltage range Residual ripple Nominal current at U N, 20 ma 9160/xx-10-10 24 V DC 18... 31.2 V ( 3.6 V SS 1 channel 57 ma 2 channels 100 ma Power consumption at U N, 20 ma 1 channel 1.4 W 2 channels 2.3 W Power dissipation at U N, R L = 250 Ω 1 channel 1.1 W 2 channels 1.7 W Polarity reversal protection yes Operation indication LED green "PWR" Undervoltage monitoring yes (no faulty module / output states) Galvanic separation Test voltages acc. to standard EN 60079-11 Ex i input to output 1.5 kv AC Ex i input to auxiliary power 1.5 kv AC Ex i input to error message 1.5 kv AC contact Ex i inputs interconnected 500 V AC acc. to standard EN 50178 Output to auxiliary power 350 V AC Outputs interconnected 350 V AC Error message contact to 350 V AC auxiliary power and outputs Ex i input Input signal 0/4... 20 ma with HART Functional range 0... 24 ma Max. input current for ma sources 50 ma Supply voltage for transmitter ) 16 V at 20 ma (for 2-wire) Residual ripple of supply voltage Open-circuit voltage ( 26 Short-circuit current Input resistance for ma sources Communication signal Output Output signal ( 25 mv eff 35 ma ( 100 Ω bi-directional HART transmission, 0.5... 10 khz Current sink, max. 30 V with HART Isolators /15

Series 9160/xx-10-10 Load resistance R L R [ Ω ] L 1400 1200 1000 800 600 400 200 0 10 15 20 25 30 U S [ V ] R max [Ω] R max R [Ω] R min [Ω] R minr [Ω] 15403E00 U S: Supply voltage R L: Load resistance R max: Max. load resistance terminal 1, 2 & 5, 6 R min: Min. load resistance terminal 1, 2 & 5, 6 R max R: Max. load resistance terminal 1, 3 & 4, 6 R min R: Min. load resistance terminal 1, 3 & 4, 6 Residual ripple Communication signal Response time (10... 90 %) Error detection Ex i input Behaviour of the output Output current at I E = 0 Signal transmission ( 40 μa eff bi-directional HART transmission, 0.5... 10 khz (at 9160/19 only output 1) ( 100 μs (at 9160/19 output 2: ( 200 ms, typ. 100 ms) = Input signal I A = 0 ma Deviation ( 0,1 % Temperature effect Electromagnetic compatibility Accuracy, typical data expressed as % of calibrated span (20 ma) at U N, 23 C ( 0.05 % / 10 K Tested under the following standards and regulations: EN 61326-1 Use in industrial environment; NAMUR NE 21 Ambient conditions Ambient temperature Single device -20... +70 C Group assembly -20... +60 C The installation conditions affect the ambient temperature. Observe the "Cabinet installation guide". Storage temperature -40... +80 C Relative humidity (no condensation) ( 95 % /16 Isolators

Series 9160/xx-10-10 Electrical connection Connection diagram 1 channel, output: passive / sink 9160/13-10-10. Division 1 Zone 0 / 1 Division 2 Zone 2 1 channel, outputs: passive / sink 9160/19-10-10. Division1 Zone0 / 1 15328E02 Division2 Zone2 15329E02 2 channels, outputs: passive / sink 9160/23-10-10. Division1 Zone0 / 1 Division2 Zone2 15330E02 Isolators /17

Series 9160 Series 9160 Mechanical data Connection Single-wire connection - rigid - flexible - flexible with core end sleeves (without / with plastic sleeve) two-wire connection - rigid - flexible - flexible with core end sleeves Screw terminals 0.2... 2.5 mm 2 0.2... 2.5 mm 2 0.25... 2.5 mm 2 0.2... 1 mm 2 0.2... 1.5 mm 2 0.25... 1 mm 2 Weight approx. 160 g Mounting type on top hat rail (NS35/15, NS35/7.5) or in pac-carrier Mounting orientation horizontal or vertical Enclosure IP30 Terminals IP20 Enclosure material PA 6.6 Fire resistance (UL-94) V0 Spring clamp terminals 0.2... 2.5 mm 2 0.2... 2.5 mm 2 0.25... 2.5 mm 2 0.5... 1 mm 2 Dimensional Drawings (All Dimensions in mm / inches) Subject to Alterations X 99 [ 3, 90 ] 17,6 [0,69] Dimension X Screw terminals 108 mm / 4.25 Spring clamp terminals 128 mm / 5.04 114,5 [ 4, 51 ] 122 [ 4, 80 ] 09685E00 We reserve the right to make alterations to the technical data, dimensions, weights, designs and products available without notice. The illustrations cannot be considered binding. /18 Isolators