Mini Receiver. Off Peak System Control. Operation & Installation Guide for Power Line Carrier WARRANTY. (Applicable to Software Version

Similar documents
POWER TRACE TM TASCO, INC.

IRRIGATION 810-T PLUS TRANSMITTER GUIDE

Rev /13 SSRMAN-1B SERIES USERS MANUAL SSR INTELLIGENT BURST FIRING CONTROL COPYRIGHT 2013 NUWAVE TECHNOLOGIES, INC.

AMERITRON RCS-12 AUTOMATIC ANTENNA SWITCH

CCE Image may differ from the actual product By Martin Labbé, eng., Jasmin Goupil & Louis Perreault

Ricochet Alphasonic Level Transmitter Model LA15/20 Owner s Manual

Indoor Contact Input Photosensor

FA401 Single Transmitter / Single Output Receiver. FA401R Single Transmitter / Single Relay Output Receiver. Installation Instructions 02305C

Copyright 2014 by Minarik Drives

X80 Activator. User's Manual. Version 1.1.

Operating Guide SMH 1525DT SMU 4525KT Technology Drive West Melbourne, FL RELM Wireless Corporation. All Rights Reserved CC OG 23

INSTALLATION INSTRUCTIONS

Broadband Step-Up Transformer. User Manual

Rev.8.8 SSRMAN-1P SERIES USERS MANUAL SSR INTELLIGENT PHASE ANGLE CONTROL MODULE COPYRIGHT 2015 NUWAVE TECHNOLOGIES, INC.

USER S MANUAL PROCESS CONTROL MODULE PCM3

SureCall TM CM800 65dB

BATTERY SENSOR. User Manual. Manual Version: BMS

Everything will be securely inserted inside the box so items do not shift during shipping and handling. Rev D 2

SureCall TM CM dB Dual Band Universal Inbuilding Repeater

Instruction Sheet SNE SERIES. Cable Chase

1410T/LCD-A INSTALLATION AND OPERATING INSTRUCTIONS

BC145 SIGNAL ISOLATOR BOARD

PixController, Inc. Wireless Vibration Sensor For Indoor and Outdoor Use

User s Guide Instructions for Installation and Operation

TRANSFORMER HD-HAMPTON HAMPTONBAY.COM

Schooners II. Weatherproof Wireless 900MHz Speaker System. User Guide. Model no.: GDI-AQSHR200 / AQSHR21

RTC. Redundant Transmitter Controller FM RTC. Redundant Transmitter Controller. User's Manual

Ricochet Alphasonic Level Transmitter Model LA15 Owner s Manual

C2000 Operational Manual

A1000 ALPHA and A1200 ALPHA Meter Installation Instructions. General. Installation. For A1000 ALPHA Type R, A1000 ALPHA Type C, and A1200 ALPHA Meters

CDT. Service and Installation Manual. Manual Revision Oct 2014

An American Control Electronics Brand PCM4 SERIES USER MANUAL PCM4.

Installation and Operation Manual MSI. Multi-Sensor Interface Hub. Interface Module for all Sensors Network and Wireless CAUTION

INSTALLATION INSTRUCTIONS

Series 3000 Model R-107A

OWNER S MANUAL DANGER

T-L 810-T TRANSMITTER GUIDE

INSTALLATION AND SETUP GUIDE

Digital Lighting Systems, Inc.

WARNING: Do not work around outlets while the power is on. Do not stick fingers or tools into an electrical box while the power is on.

Classic Series Public Address Amplifiers C10 & C20 Models

FA404 4 Transmitter / Single Output Receiver FA404R 4 Transmitter / Single Relay Output Receiver

Questions? Call Toll-Free

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

User Manual. Smart-UPS On-Line. Uninterruptible Power Supply. Isolation Transformer Models: SURT001 and SURT002

INSTALLATION AND OPERATING INSTRUCTIONS MODEL SIVF. KB Part No Signal Isolator for KBVF Controls. See Page 1 Pending

Earth Fault Indicator EFI-BLZ-50 User Manual

10 Amp Digital PWM Motor Speed Controller CV-2110-HD and CV-2110-HDS

f i r e - p a r t s. c o m

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

Model: Smart Stat III INSTALLATION AND OPERATION INSTRUCTIONS

5001 INSTALLATION AND OPERATING INSTRUCTIONS

MODEL 421 Over/Under Motor Load Monitor

MODEL 3810/2 Line Impedance Stabilization Network

MICRO GROW GREENHOUSE SYSTEMS, INC YNEZ RD., SUITE C-4, TEMECULA, CA PHONE (909) FAX (909) Revision 1.

15 Amp Digital High Frequency PWM Motor Speed Controller SPD-315-D and SPD-315-DS

NEO CAR AUDIO. Neo AUXiN AUX INPUT INTERFACE. Instruction Manual

Fiber Optic Expansion Interface

IRRIGATION 810-T TRANSMITTER GUIDE

PARALLEL MULTI-AMP KIT for 7200 Series AMPLIFIERS INSTRUCTION SHEET

40 Amp Digital Bidirectional PWM Motor Controller with Regenerative Braking BIDIR-340-DR

MST-5. Varifan USER S MANUAL MST-5 5 STAGE THERMOSTAT. computer compatible ADJUST. 9 reduc. per day 8 7 F rel. rel. rel. rel.

Safety. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.

Instruction Sheet REB SERIES. Rotating Sliding Base REB18

IS7705. Installation & Operation Manual AUDIO INTEGRATION KIT. TranzIt LINK

Pushbutton Bollard. Wireless Control for BlinkerSign, RRFB or BlinkerBeacon User Guide. Blinker Division Solar LED Solutions

Warranty Terms & Conditions

ELECTRONIC SHEAR PIN MODEL ESP 1 & 2 INSTRUCTION MANUAL

ER200 COMPACT EMERGENCY CRANK DIGITAL WEATHER ALERT RADIO OWNER S MANUAL

Taurus CP-300 Single Pump

Electronic Circuit Breaker ECONOMY REMOTE

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K

Table of Contents. Safety Notices

Keychain Radio Remote Control System

OD-2 Series 50W & 100W Amplifier Operation Manual Manual V2.00

SYSTEM OPERATING CONTROLS

LBI-38976A. Mobile Communications MDX/ORION DESK TOP STATION. Operator's Manual

Rock Sounders. Weatherproof Wireless 900MHz Speaker System. User Guide. Model no.: GDI-AQRCK400 / AQRCK41

Master Reference Unit

Signal Isolation Module. Instruction Manual SIM

Smart-UPS On-Line Isolation and Step-Down Transformer SRT5KTF

SSR-150xxx-40VL-12P-xC-xxxCS

IRRIGATION 810-R RECEIVER GUIDE

Model CC4041. CC Series Amplifier. Installation and Use Manual

PULSE DISTRIBUTION AMPLIFIER OPERATING MANUAL

USER MANUAL MODEL Parallel to Serial/ Serial to Parallel Interface Converter

2011 / Circuit Tracer

Field Hub Installation Guide. P/N Rev. C 05/15

SSR VL-12P-xC-NCS

Radio Remote Controls Manual K Series

Installation Instructions

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

Independent Technology Service Inc Independence Ave. Chatsworth, California Toll Free:

Comfort 10S Wall Hardwire Installation and Operations Manual

Wireless Transceiver (TRV)

LBI Mobile Communications MDX DESK TOP STATION. Operator's Manual

Instruction Sheet. VRS Series. Vertical Rackmount system for multiple cable/satellite receivers

Using the USB Output Port to Charge a Device

IRRIGATION 810-3R RECEIVER GUIDE

PROTOCOL WISH4 & WISH4-RP

Transcription:

MR9 WARRANTY Steffes Corporation ( Steffes ) warrants that the Steffes Power Line Carrier Mini Receiver is free from defects in materials and workmanship under normal use and service. Steffes obligation under this Warranty is limited to the repair or replacement of the appliance or parts only which prove to be defective under normal use within one (1) year of the date of installation and which Steffes examination of the returned device or part(s) shall verify to Steffes satisfaction that it is defective. The user shall be responsible for any labor costs associated with the repair or replacement of the device or part(s) including the cost of returning the defective appliance or part(s) to Steffes Corporation. This Warranty is void if the device is moved from the premises in which it was originally installed. This Warranty shall not apply to a device or part which has been altered in any respect, or improperly installed, serviced or used, or has been subject to accident, negligence, abuse or misuse. THE ABOVE WARRANTY BY STEFFES IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES, WHETHER WRITTEN OR ORAL, EXPRESS OR IMPLIED, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY OR OF FITNESS FOR A PARTICULAR PURPOSE. The user assumes all risk and liability whatsoever resulting from the use of this device. In no event shall Steffes be liable for any indirect, special or consequential damages or lost profits. This Limited Warranty contains the complete and exclusive statement of Steffes obligations with respect to this device and any parts thereof. The provisions hereof may not be modified in any respect except in writing signed by a duly authorized officer of Steffes. Operation & Installation Guide for Power Line Carrier Mini Receiver (Applicable to Software Version 15.0 15.9) Manufactured in North America 3050 N Highway 22 Dickinson, ND 58601 9413 701 483 5400 Commitment to Innovation DOCUMENT #1200057 Off Peak System Control

9 5 0 4 CTS 206 8 WARNING HAZARDOUS VOLTAGE: Risk of electric shock. Can cause injury or death. This device may be connected to more than one branch circuit. Disconnect all branch circuits before servicing. SPECIALTY APPLICATION WIRING DIAGRAM (six pole configuration utilizing power line carrier signal and an auxiliary control device) This Device MUST be Grounded. Grounding and Bonding is not shown in this Diagram. IMPORTANT The equipment described herein is intended for installation by a qualified technician in accordance with applicable local, state, and national codes and requirements. This manual should be retained by the owner upon completion of the installation and made available to service personnel as required. Disclaimer: Conditions may occur which cause the power line carrier transmitter and receivers to have difficulties communicating; therefore, not operating properly. In no event shall Steffes Corporation be liable for any indirect, special, or consequential damages or lost profits. In compiling this manual, Steffes Corporation has used its best judgement based upon information available, but disclaims any responsibility or liability for any errors or miscalculations contained herein, or any revisions hereof, or which result, in whole or in part, from the use of this manual or any revisions hereof. Steffes Corporation does not guarantee effective communication of the PLC system in all applications and is not responsible for any communication issues outside normal operating malfunctions. In This Example, Circuits 4,5,&6 are Controlled by PLC Signal Only CIRCUIT 6 CIRCUIT 5 CIRCUIT 4 CIRCUIT 3 CIRCUIT 2 CIRCUIT 1 Optional Auxiliary Control (i.e. room thermostat) T1 L2 T1 L2 T1 L2 T1 L2 T1 L2 T1 L2 CIRCUIT 1 Low Voltage Terminal Strip CIRCUIT 2 9 10 1 2 3 4 5 6 7 8 COM CR1 CR2 CR3 CIRCUIT 3 120 O N 240 CR4 CR5 CR6 CIRCUIT 4 CIRCUIT 5 CIRCUIT 6 In This Example, Circuits 1, 2, and 3 are Controlled by PLC Signal and by an Optional Auxiliary Control. FOR CUSTOMER USE Please record the serial number of the mini receiver below. This information is located inside the mini receiver enclosure. Retain this information for future reference. Serial No. 9

NOTES (For reference to these notes, refer to the wiring diagrams on Pages 6 and 7 in this manual.) NOTE 1: For more information on the dip switches, refer to the Dip Switch Settings section in this manual. NOTE 2: Mini receiver configuration must be specified at the time of factory order. NOTE 3: The mini receiver operates on 120V or 208V/240V, single phase. In the single and double pole configuration mini receivers, line voltage connections must be made in the terminal block to configure it to the voltage input being connected to. The six pole configuration mini receiver is factory configured to operate on 208V/240V. If connecting it to 120V, the line voltage connections in the terminal block must be reconfigured and must be the ungrounded leg. NOTE 4: All line voltage wiring in this device must remain below and in front of the line voltage barrier inside the mini receiver enclosure. NOTE 5: In the 6 pole mini receiver, circuit 1 feeds both output circuit 1 and the mini receiver s internal controls. NOTE 6: With the 6 pole mini receiver, loads connected between & L2 on circuit 1 will be uninterrupted. Loads connected between T1 & L2 on circuit 1 will be interrupted. NOTE 7: Circuit 1 maximum fuse size is 20 amps. Maximum load is 16 amps. Any loads requiring greater than a 20 amp circuit MUST never be connected to circuit 1. NOTE 8: Circuits 2 6 maximum fuse is 30 amps. Maximum load is 24 amps. Maximum Fuse Size (6 pole) Total Input Circuit Ampacity (6 pole) Circuit 1 = 20 AMP Surface Mounted = 120 AMPS (16 AMP Load, Max) Flush Mounted = 80 AMPS Circuit 2 6 = 30 AMP (24 AMP Load, Max) NOTE 9: To ensure proper communications between the PLC Mini Receiver and it s correlating transmitter, the mini receiver MUST be grounded. The system grounding and bonding must be sized and installed in compliance with all applicable codes. GENERAL OPERATION The Steffes Power Line Carrier (PLC) Mini Receiver is designed to provide wireless control of one electrical circuit (single pole configuration), two electrical circuits (double pole configuration), or six electrical circuits (six pole configuration). It receives signals through the existing power lines from the Steffes Power Line Carrier (PLC) Transmitter or Comfort Control Relay Panel (CCRP). The built in 30 AMP relay(s) are capable of controlling devices such as: ETS heaters, water heaters, baseboards, electric furnaces, dryers, dishwashers, hot tubs, ceiling cables, or other electrical equipment. When the mini receiver receives a signal, its relay(s) are activated to control the device(s) connected to them. This type of control can minimize the overall cost of controlling electrical devices. PLC Communication is very reliable in most applications but can be affected and hindered by connection method used, electrical layout of the application, operation of other equipment in the same electric system, dirty power, etc. Steffes Corporation does not guarantee effective communication of the PLC system in all applications and is not responsible for any communication issues outside normal operating malfunctions. FEATURES One, two, or six DC held, 30 AMP, board mounted relay(s) pre wired with 10 AWG leads. (Configuration must be specified at the time of factory order.) Receives peak and anticipated peak (pre peak) control signals via the power lines from the Steffes PLC transmitter system. Fifteen selectable communication channels. Capable of controlling a device on a rate/control strategy separate from the master control. All configurations are available in metal, flush or surface, indoor mounted enclosures with power company seal/lockout provision. Single and Double Pole Configurations: 6 x 6 x 3 (Outdoor enclosure available as special factory order.) Six Pole Configuration: 10 x 16 x 4.25 Maximum Fuse Size (6 pole) Total Input Circuit Ampacity (6 pole) Circuit 1 = 20 AMP Surface Mounted = 120 AMPS (16 AMP Load, Max) Flush Mounted = 80 AMPS Circuit 2 6 = 30 AMP (24 AMP Load, Max) Controls 120V or 208V/240V, single phase devices connected to single or three phase systems. Indicator lights to monitor PLC operation or relay status. Optional 90 minute peak override module available. 8 1

INDICATOR LIGHTS In its standard configuration, when the mini receiver is first energized, a red light on the circuit board will begin to flash slowly. This indicates the receiver is waiting for a signal. When valid bits of information are received, the light will begin flashing more rapidly. There may be occurrences where the light will switch from a fast flash back to a slow flash. After several minutes, the mini receiver will synchronize with the transmitter, and the light will illuminate continuously to indicate complete information is being received. This red light monitors power line carrier (PLC) communication as follows: Slow Flash: Mini receiver is waiting for PLC communication. Fast Flash: Mini receiver is receiving partial PLC communication. Continuous Illumination: Mini receiver is receiving complete PLC information There is also an amber indicator light on the circuit board. This light is used to indicate whether the relays are open or closed. It will also indicate if a peak override has been initiated. The amber light monitors the status of the relays as follows: No Illumination: relay(s) open Flashing: overrride enabled Continuous Illumination: relay(s) closed These lights can only be seen when the mini receiver enclosure is open. They are not accessible to the user in normal operation. TYPICAL SYSTEM WIRING DIAGRAM (six pole configuration) SYSTEM GROUND (See Note 9) 240VAC SOURCE 6 1 7 2 8 3 T1 L2 CIRCUIT 6 LOW VOLTAGE TERMINAL STRIP 9 4 COM CR1 CR2 CR3 CR4 CR5 CR6 10 5 TYPICAL SUPPLY CIRCUITS (See Note 5) Black Circuit 1 Red Circuit 1 Black Circuit 3 Red Circuit 3 OVERRIDE OPTION (Power Company Permitting) The mini receiver is available with a 90 minute override option. If the override is incorporated, it allows the use of a normally controlled device(s), such as a water heater, during a peak control time. It allows for a single override of either all connected circuits or a one zone override of circuits 1, 3, 5, and 6. This feature works well in areas using a Time of Use rate/control strategy. (Installation instructions for this feature are provided with the override module, item #1302070.) (See Note 4) T1 L2 T1 L2 T1 L2 T1 L2 T1 L2 CIRCUIT 1 CIRCUIT 2 CIRCUIT 3 CIRCUIT 4 CIRCUIT 5 (See Note 6) 120 240 (See Note 3) COM CR1 CR2 CR3 CR4 CR5 CR6 Factory installed wire leads. (This end is connected at the Factory to the relays and terminal block.) An override period can be initiated during a peak period or if communication between the transmitter and mini receiver is lost. To do so, press and hold the override button for 2 seconds. A new 90 minute override period can be initiated any time during a current override cycle. When an override is initiated, it cannot be cancelled manually. The override will cancel itself at the end of the 90 minute override cycle or at the start of the next off peak period, whichever comes first. CIRCUIT 3 (See Note 8) CIRCUIT 1 (See Note 7) DIP SWITCHES (See Note 1) The position of dip switch #8 on the mini receiver circuit board will determine which relays are enabled when an override is initiated. (For more information, refer to the Dip Switch Settings section in this manual.) For reference to the NOTES listed in this diagram, refer to the Notes section on page 8 in this manual. 2 7

LINE VOLTAGE WIRING AND CIRCUIT BOARD CONFIGURATION DIAGRAM (single pole or double pole configuration) This Device MUST be Grounded. Grounding and Bonding is not shown in this Diagram. TO CONTROLLED LOAD # 2 BLACK TO CONTROLLED LOAD # 1 BLACK OVERRIDE LIGHT DIP SWITCH SETTINGS DIP SWITCH 1: ANTICIPATED PEAK (PRE PEAK) OPERATION MODE This dip switch determines how an anticipated peak (pre peak) signal will affect the mini receiver s relay(s). For power companies desiring to control loads separately using multiple signals, this dip switch can be used to do peak control of devices on a separate rate/control strategy. Off = Relay(s) will not respond to an anticipated peak (pre peak) signal. On = Relay(s) will be activated by an anticipated peak (pre peak) signal. The peak signal is priority signal. When a peak signal is being received, no other signal will be recognized. 30 AMP RED RELAY 1 RED 30 AMP RELAY 2 DIP SWITCHES MICROPROCESSOR INDICATOR LIGHT TRANSFORMER DIP SWITCH 2, 3, 4 & 5: PLC CHANNEL SELECTION The mini receiver can receive information on one of fifteen channels, depending on which channel the transmitting device is set to transmit on. The mini receiver and the transmitting device MUST be set to the same channel for proper communication to occur. To select the Power Line Carrier channel desired, use the chart below and set dip switches 2, 3, 4,and 5 to the proper positions. FACTORY DEFAULT SETTING = Channel 3 (2 ON, 3 ON, 4 OFF, 5 OFF) A specific channel must be selected at time of installation. (See Note 1) L2 L2 2 POLE OPTION (See Note 2) (See Note 4) 120 VOLT 240 120 L2 208/240 VOLT SPECIAL ( ORDER ) For reference to the NOTES listed in this diagram, refer to the Notes section on page 8 in this manual. 277V OR 240 120 L2 LINE VOLTAGE CONNECTIONS (See Note 3) CHANNEL DIPSWITCH 2 DIPSWITCH 3 DIPSWITCH 4 DIPSWITCH 5 0 OFF OFF OFF OFF 1 ON OFF OFF OFF 2 OFF ON OFF OFF 3 ON ON OFF OFF 4 OFF OFF ON OFF 5 ON OFF ON OFF 6 OFF ON ON OFF 7 ON ON ON OFF 8 OFF OFF OFF ON 9 ON OFF OFF ON 10 OFF ON OFF ON 11 ON ON OFF ON 12 OFF OFF ON ON 13 ON OFF ON ON 14 OFF ON ON ON 15 ON ON ON ON 6 3

DIP SWITCH SETTINGS CONTINUED. DIP SWITCH 6: AUTOMATIC SHOULDER CHARGE (Specialty Applications Only) This dip switch allows for a shoulder charge period for the device controlled on relay #1. Five (5) hours after a peak signal is received, relay #1 will close for four (4) hours. The relay will then open again and will remain open until an offpeak or anticipated peak signal is received. If an off peak or anticipated peak signal is received during the five hour period, the timer will reset. Off = Shoulder charging disabled On = Shoulder charging enabled The duration of the delay and the outdoor temperature settings are preset at the factory. If you have an application which requires a change to these settings, please contact the factory. DIP SWTICH 7: DEFAULT RELAY STATUS This dip switch determines how the relay(s) will respond when the power line carrier control system is first energized or if the mini receiver loses signal from the transmitter. Off = The relay(s) will open until a signal is received from the PLC transmitter. On = The relay(s) will close until a signal is received from the PLC transmitter. DIP SWITCH 8: PEAK CONTROL OVERRIDE With the addition of the override module to the mini receiver, peak override of some or all of the circuits is possible. Depending upon the position of this dip switch, either all circuits in the mini receivers or just those connected to relays 1, 3, 5, and 6 can be used in 90 minute intervals during a peak control period, if desired. FACTORY DEFAULT SETTING = ON Off = Circuits connected to relays 1, 3, 5, and 6 are enabled during a peak control time when an override cycle is initiated. On = All circuits in the mini receiver are enabled during a peak control time when an override cycle is initiated. DIP SWITCH SETTINGS CONTINUED. DIP SWITCH 9: RELAY 3 AND 4 FUNCTION SELECTOR (Six Pole Configurations Only) This dip switch is used in conjunction with dip switch 6. If dip switch 6 is in the on position, the position of dip switch 9 will determine how relays 3 and 4 will respond. Off = Relays 3 and 4 will function like relay 2 On = Relays 3 and 4 will function like relay 1 DIP SWITCH 10: RELAY 5 AND 6 FUNCTION SELECTOR (Six Pole Configurations Only) This dip switch is used in conjunction with dip switch 6. If dip switch 6 is in the on position, the position of dip switch 10 will determine how relays 5 and 6 will respond. Off = Relays 5 and 6 will function like relay 2 On = Relays 5 and 6 will function like relay 1 INSTALLER S FINAL CHECK OUT PROCEDURE 1. Prior to energizing the electrical circuit feeding the mini receiver, inspect all field installed electrical connections to ensure they are tight and that all wires are routed correctly. All line voltage wiring must remain below and in front of the line voltage barrier inside the mini receiver. To ensure proper communication with the PLC transmitter, the mini receiver must be grounded. 2. Check the settings of the dip switches on the mini receiver board to ensure they are in the correct positions for the application. The desired PLC channel MUST be selected for communication to occur. 3. Check to ensure that the red indicator light on the mini receiver circuit board is illuminated continuously indicating communication is occurring between the transmitter and the mini receiver. Communications between the transmitter and the mini receiver occur on a continuous basis. Upon energizing a system, there will be some delay in a receiver s response to transmitter signals. It takes approximately seven (7) minutes for the transmitter to establish initial communication. Subsequent communication will occur more rapidly. 4. Once good communication is established, verify that the mini receiver responds correctly to the corresponding utility peak signal status. The amber indicator light will illuminate when the relay(s) are closed and should remain off when the relay(s) are open. 4 5