Ron 2000 Shackle Type Dynamometer with Remote Indicator

Similar documents
Ron 2150 Shackle Type Dynamometer with 2"/50mm Attachable Display

Manufacturer of Ron StageMaster Years OF MEASURING EXCELLENCE

Force and weight measuring instruments

The Standard for over 40 Years

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:

GS820-CSA. GS820-CSA class 1 division 2 specifications. Features: Applications: General Description:

GS550-CSA. GS550-CSA class 1 division 2 specifications. Features: Applications: General Description:

AIRCRAFTSCALES.COM WIRELESS WEIGHING INSTRUCTIONS.

Continuously monitors and stores the levels of Electromagnetic fields Up to four simultaneous bands: GSM 900 / 1800 MHz / UMTS / Broadband 100 khz 3

Loc-1Tx/Loc-5Tx/Loc-10Tx Data Sheet V3.2

MRP Rs.20,000 Free Home Delivery Offer Price Rs.11,000 Inclusive of Taxes Save Rs.9,000 1 Year Warranty. Part No K0

MIT400/2. CAT IV Insulation testers MIT430/2: CAT IV Insulation testers

GS Strain gauge reader/ transmitter. GS series of wireless industrial sensors. Features: General Description: Applications:

GS550-CSA/ATEX-CE. GS550 for Hazardous Locations. Features: Applications: General Description:

LI-1500 Light Sensor Logger

UTILITY LOCATING EQUIPMENT

DITCH WITCH ELECTRONIC GUIDANCE EQUIPMENT

G5 System Family and Accessories

English. Money Counter. Coin and banknote counter. DEUTsCH. Manual

SonoMeter 31 Energy Meters

multi-function + auto-range, CATIII 1000V ACV/DCV/OHMS/4 to 4000 M ohm, 100V, 250V, 500V, 1000V INSULATION TESTER

MODEL AT-10 ANALOG TRANSMITTER

Frequency selective monitoring and logging of environmental electromagnetic fields

MIT400/2 CAT IV Insulation testers

1510A PRECISION SIGNAL SIMULATOR

RCF 3.4. Portable Traffic Signal - Technical Specifications. North America Traffic Inc REV#

Insulation Testers and Earth Ground Testers

KATflow 230 Portable Clamp-On Ultrasonic Flowmeter

CAT-1 TM Transmission Line Monitoring Systems

DataSheet. Tinytag Radio System

GS030. Crane Slew-Angle Wireless Measurement Sensor. Features. Application

Standard Halogen Light

Wireless Data Logger RTR-500 Series Data Loggers Features and Specs

Load Cells Page Option Option

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

ID/HX-EP SERIES DIGITAL OUTPUT

SVM F22. Calculator for heating or cooling applications. Data sheet

Proximity Probe Checker PC-100

HX-EP SERIES DIGITAL OUTPUT

MIT400/2 CAT IV Insulation testers

Ultrasonic Bolt Load Measurement

MIT400 CAT IV Industrial Insulation Testers

POWER ANALYZER OPERATION MANUAL. Model : DW-6090A

English. Money Counter. Coin and banknote counter. DEUTsCH. Manual

MIT400 CAT IV Industrial Insulation Testers

Operators Manual For Spectrum Analyser SA97

Applications Features

Conductivity Analyzer

INSULATION TESTER SERIES Selection guide

Digital Wireless Weather System

UltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER

9320 Manual Portable Battery Powered Indicator

Wireless Temperature Sensor with Probe

Load Cells Page Option Option

Wireless Temperature Sensor

Digital insulation tester

Wireless Magnet Detection Sensor

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

BM25 Automated 5-kV Insulation Tester

Laboratory Grade Instruments Series & 4021 Power Meter SERIES Power Sensor

Fluke 1740 Series. Three-Phase Power Quality Loggers Memobox. Assess power quality and conduct long-term studies with ease

MIT400 CAT IV Industrial Insulation Testers

Technical Specifications

EL-USB-5 Counter, Event and State USB Data Logger

G-NET. 1 kva-10 kva. Rack & Tower UPS

Recorders OUR MOST COMPACT CHART RECORDER! Input Number Chart Special Description Type of Pens Size Options Page

Remotus. Robust radio remote control for safety critical industrial applications ROBUST SWEDISH DESIGN SINCE 1918

Accutech GP10. Wireless gauge pressure field unit

INTRODUCTION. Strong Performance: High resolution and penetration, achieving precise flaw detection

For easy-to-use loggers, look no further! Connect to a tablet, smartphone, or PC for easy, wireless data collection

WATERFLUX 3070 Technical Datasheet

Infocal 9 Energy calculator

Synthesized Transmitter

GENERAL PURPOSE INDICATOR LOOP POWERED WITH VERY LARGE DIGITS DATASHEET F090 - GENERAL PURPOSE INDICATOR

Model 41E. Precision Low Profile Load Cell DESCRIPTION FEATURES

MIT415 Insulation tester

Real-time current profiles and directional waves for intermediate water

2.7 GHz FREQUENCY COUNTER with TCXO

CIPS, DCVG & GPCM Pipeline Surveyor. Corrosion Control Equipment

TORKEL 900-series Battery Load Unit

CP 6632 Handheld process signal calibrator

PM 6669 High-Precision Frequency Counter Specifications

TRACEABLE RADIO-SIGNAL REMOTE THERMOMETER INSTRUCTIONS

Sarasota CM200 Sarasota HME900 Density Converter Electronics

Introducing GPI s Latest

AN Wireless analog data acquisition system with 4-20 ma (current loop) inputs and built-in data logger

1: Introduction : Caution : Tips for Reading this Manual : Preface : System Highlights : Receiver

Precise Counting Scale GC. User Manual SNOWREX INTERNATIONAL CO., LTD. SRGC

Model R7900. Instruction Manual. Ultrasonic Thickness Gauge. reedinstruments. www. com

AA-35 ZOOM. RigExpert. User s manual. Antenna and cable analyzer

RMU3 Remote Monitoring Unit and GPS Interrupter

Fluke and

SUBSURFACE INSTRUMENTS, INC. AML PRO & AML+ PRODUCT GUIDE

This manual applies to the WT-RC-Ex receiver when used to locate all makes and models of 22 Hz and Wavetrak coded transmitters.

GROUND TESTERS For all of your Ground Testing needs...

Loop & Magnetic Field Coil

ION PRODUCTS. Sensor Testers

PH METER OPERATION MANUAL. Model : PH-208

For easy-to-use loggers, look no further! WIRELESS MINI LOGGER LR8512, LR8513, LR8514, LR8515

ELECTRICAL TESTING EQUIPMENT. CLM100 Cable Length Meter. DMEG3 Digital Insulation Resistance Tester. IRT3 Analog Insulation Resistance Tester

Transcription:

Ron 00 Shackle Type Dynamometer with Remote Indicator Short delivery time: Usually - 4 business days. High quality Aerospace Steel for increased strength and safety. Exceptionally small dimensions enable minimum headroom loss and portability. For example: Height of the.t load cell is. inch / mm Weight:. lbs /.4kg More than three decades in the market: Eilon Engineering Ltd. has specialized in the development and manufacturing of Ron crane scales and dynamometers since 976. We have thousands of repeat customers such as NASA, Boeing, US Air Force and many more. Ron Alternatives Standard remote display enables the user to conveniently read the measured values form a safe distance. Exceptionally long battery life: Up to 00 hours on AA disposable batteries with battery life indication. Unique design: 90 between shackle holes eliminates external moments and consequently increases accuracy, safety and longevity. Optional wireless communication to additional display or PC that allows for multiple Ron crane scales / dynamometers in one area to send measurements to a centralized location. New: Fatigue rated load cells - an important and unique safety feature: All Ron crane scales and dynamometers are now Fatigue Rated. They have an improved fatigue resistance level. Shackles not included Wide temperature range: Load cell: - F to +7 F ( - C to + 0 C ) Indicator: -4 F to + F (- C to +70 C). Double overload warning is displayed on the screen at 0% of full scale ant at 0%. Advanced options such as: Integrated data logger, analog output, averaging / dampening and more Optional offshore and underwater load cell sealing levels: High sealing levels IP 67 and IP 6 for offshore and underwater applications.

Ron 00 Shackle Type Dynamometer with Remote Indicator Description Ron 00 Shackle Type is a small, lightweight and portable Dynamometer. It is therefore especially suitable for applications that require portability and minimum headroom loss (for example indoors applications). Ron 00's long battery life (up to 00 hours) is also an important feature for working long periods on site. Ron 00 is a basic, easy-to-operate and very reliable dynamometer. It was first launched in 9 and since then many thousands of Ron 00 dynamometers have been sold worldwide. The load cell's unique perpendicular hole structure neutralizes external moments and thus improves safety and accuracy. The optional additional wireless display enables transmission of the measured values to a remote location. Dynamometers are used for weighing during lifting, force measurement (bollard pull tests), tension measurement (the dynamometer then serves as a tension load meter, used for cable tension measurement, etc.), load measuring and load control. Ron 00's indicator is separated from the load cell and is held by the user. This separation ensures the user's safety since under no circumstances will they have to approach the load in order to read the result. This separation also guarantees the dynamometers' durability. Another feature that increases the system's durability is the electronic board's dampening mounts that increase the system's durability to external impact. With more than 0 years in the crane scales and dynamometers market, Ron Crane Scales is one of the leading brands in the global market with repeat customers like NASA, Boeing, GE, Siemens and many others.

Ron 00 Shackle Type Dynamometer with Remote Indicator Specifications Safety Factor: Designed to : Proof Load: Each system proof-loaded to 0% of capacity (certified) up to a test force of 400t. Accuracy: ± 0.% of full range. Display: digit, /" (mm) liquid crystal display with two overload warning levels, max. value (peak hold), low battery, tare state (gross or net), measuring unit, sleep state, charge and programming instructions. Standard number of measurements per second:. Standard display update rate per second:. Sampling Rate: 0 per second. Functions: Zero. Tare. Battery charge level. Low battery warning. Max. (peak hold). Twolevel overload visual alarms. User calibration. Sleep mode after sec. in zero value, awakes automatically when loaded. Units: Available in the following measurement readings: metric tons, short tons (00 lbs), kgs, Ibs (lbs x for capacities of 0t and above), newtons, deca newtons, k. newtons. Load Cell Material: Made of high-strength, aerospace quality, alloy steel, polyurethane coated. Indicator Material: High quality ABS. Power: x AA. Volt Alkaline disposable batteries, with battery life indication Batteries rated AH will function up to 00 hours (three months of continuous working). Occasional use will extend the life of the batteries up to several years. Adding certain options will shorten the life of the batteries. All settings retained at power off. Calibration: User calibration. Initial factory calibration, fully traceable (certified). Temperature Range: Load cell: - F to +7 F (- C to + 0 C) Indicator: -4 F to + F (- C to +70 C). Environmental: Weather proof NEMA4, IP 6

Ron 00 Shackle Type Dynamometer with Remote Indicator Options or user-adjustable set points Additional 0."/mm LCD display with cable connection to indicator or wireless Additional "/mm LCD display with cable connection to indicator or wireless Additional "/0mm LCD display with cable connection to indicator or wireless Additional 4"/0mm LED display with cable connection to indicator or wireless Additional extension cable in ft/m increments Analog output: 0 to V / 0 to V / 0 to V Analog output: 4 to ma Baud rate, user-selectable Carrying case: Pelican, High quality Dampened (average) display for unstable load Data logger - manual or automatic - up to 0 measurements Data logger - manual or automatic - up to,000 measurements Data logger - manual or automatic - up to 6,000 measurements Data logger - manual or automatic -up to,000 measurements Indicator belt clip IP 67 load cell with special off-shore connectors IP 6 load cell with underwater capability Longer extension cable in ft/m increments Number of measurements per seconds: Up to 0 factory set Real-time clock Rechargeable batteries with an external charger Rope falls multiplier, user selectable RS- - continuous or on demand data output, user-selectable RS-4 - continuous or on demand data output, user-selectable Totalizer Units, user-selectable Wireless communication to additional display or PC USB

Ron 00 Shackle Type Dynamometer with Remote Indicator Dimensions Table and Drawing Optional carrying case Cat no. S-00 S-0 S-0 S-0 S-0 S- S- S- S- S- S-0 S-40 S-0 S-0 S-0 S- S-0 S- S-00 Full range Resolution Load cell weight Cable length H (max.) H (max.) B (max.) D (max.) D (min.) Matching anchor shackle size* tons kgs Ibs kgs Ibs mm ft mm inch mm inch mm inch mm inch mm inch inch 0.. 0 40 0 0 0 0 00 0. 0. 0 0 0 0 0 0 0. 0 0 0 0 0 0 0 0..4.4.. 7 6 6.... 7 7 40 7 47 9 9 40 40 40 40 40 7 00 00.4..7.7 9.4 9.4.6.6.9.6.. 9 9 9 0 4 4 9 9 7 7 0 0 0 4 4....6.6.9.9... 9. 9. 9 6 4 4 7 7 97 4 7 7.6.6..... 4. 4..7 7.0 7.0 6 6 74 74 7 7 4.....4.4.4.4 4. 4..7 6. 6.... 7 7 7 6 6 44 44 76 6 0. 0.9.4.4.... 4..4.4 ½ 7/ / ½ 7/ / ½ 7/ / / ½ /4 / /4, /, /4, /, / / ½ ½, /4, /4 ½ CROSBY No. t CROSBY No. t CROSBY No. 0t CROSBY No. 40 t or No. 00t CROSBY No. 00t * USE SHACKLES WITH S.W.L. (SAFE WORKING LOAD) EQUAL TO, OR GREATER THAN THE SYSTEM'S FULL RANGE. * The company reserves the right to make changes without notice.