Flow Detection MDS Integral or Remote Housing FUNCTION TYPICAL USES. Microwave Doppler Switch Solids - Chute and Conveyor GHz Sender Receiver

Similar documents
Flow Detection MDS Integral or Remote Housing. Installation and Operating Instructions

MRS-MRR-MRA. Solid/Liquid Level GHz Sender Receiver

Gladiator. Gen 3 Microwave Switch Series. Data Sheet. Overview. A Higher Level of Performance. Beam Blockage Detection Circular Polarisation

Gladiator. Gen 3 Microwave Switch Series. Data Sheet. Overview. A Higher Level of Performance. Beam Blockage Detection Circular Polarisation

Gladiator. Doppler Microwave Series. Manual. A Higher Level of Performance. Sultan Sonar Manual Rev 1.0. Product Flow Detection Circular Polarisation

ChuteMaster Microwave-blocked chute detection and point level instrument

Echotel Model 910 Ultrasonic Level Switch

Sultan Acoustic Wave Series

Gladiator. Gen 3 Doppler Microwave Switch Series. Data Sheet. Overview. A Higher Level of Performance. Product Flow Detection Circular Polarisation

Sultan Liquid- Acoustic Wave Technology

Gladiator. Gen 3 Microwave Switch Series. Manual. A Higher Level of Performance. Sultan Sonar Manual Rev 1.0

Echotel Model 910 Ultrasonic Level Switch

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

Lazerpoint TM RF RX-91 Basic Receiver Installation Instructions

INSTRUCTION MANUAL ADMITTANCE LEVEL LIMIT SWITCH LEVTESTER - SLA SERIES Models SLA-122/222/322/622/522/722

Electro-Magnetic Flowmeters COPA-XE

Switching. Radar. Overview 114 VEGAMIP series Mounting adapter 120

With Audible Detect Signal

Echotel Trident 91S/92S Ultrasonic Level Switches

RF-CAPACITANCE (Coat-Shield)Level Limit Switch

Page/Talk Weatherproof Wall Stations Models MLW80 and MLW85

Level Lance Model 5100

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

INSTRUCTION MANUAL. Microwave Smart Switch Series. - Beam Blockage Detection - A higher level of performance

Level Measurement Continuous level measurement Radar transmitters

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Level Measurement Continuous level measurement Radar transmitters

Gladiator G1 Series. Microwave Waveguide Information. Data Sheet. Overview. A Higher Level of Performance. Beam Blockage Detection

Level Measurement. Continuous level measurement - Radar transmitters SITRANS LR400 5/229. Overview

Gladiator G1 Series. Microwave Waveguide Information. Data Sheet. Overview. A Higher Level of Performance. Beam Blockage Detection

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:

ORCA. Sonar System. Data Sheet. A Higher Level of Performance. Sludge and Settling Level Interface Monitoring.

600T Series Transmitters. Specification Sheet. Model 653T Electronic temperature transmitter (PC programmable)

400 (±2,5 V/ V/ ,3% V4A

Level Measurement. Continuous level measurement Radar transmitters SITRANS LR460. 4/258 Siemens FI

TEK-F LEX 4100A. Guided Wave Radar Level Transmitter. LEVEL. Technology Solutions

This product is for use in a dry, indoor environment only. This product is not to be installed near water, liquid, or flammable materials.

Flow Measurement SITRANS F M

Sultan Flow. Data Sheet. Overview. A Higher Level of Performance. Real Time Flow Measurement for Liquids.

SULTAN 234 Series. Acoustic Wave Level Transmitter SULTAN 234 Series Smart Universal Level Transmitter & Network

ORCA. Sonar System. Data Sheet. A Higher Level of Performance. Sludge and Settling Level Interface Monitoring.

Sultan. Sonar System. Data Sheet. A Higher Level of Performance. Sludge and Submerged Interface Level Measurement.

DU3 Ultrasonic Vehicle Detector

FEATURES OPTIONAL FEATURES

The transducer component converts the measured signal and displays the actual value.

FMR ELSEMA 1-Channel 151MHz Receiver - FMR15101

600T Series Transmitters Model 653L Electronic temperature transmitter (PC programmable for RTD and resistance) Specification Sheet

Soliphant T FTM20, FTM21

INSTALLATION and OPERATION INSTRUCTIONS. FOR FiberLink BI-DIRECTIONAL AMPLIFIER WITH DIVERSITY MW-FBDA-800AB-50W-DIV

Echotel Model 911/921 Ultrasonic Level Switches

LST400 Ultrasonic level / open channel flow transmitter

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

Effective: June, 2000 EX-1821 Satellite Display Unit Receiver Installation Manual Models: 4643-*-* 4644-*-9 Since 1937

CAP ANALOG 410 INSTALLATION & OPERATION MANUAL

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Introducing GPI s Latest

Baymaster LED Luminaire High Bay for Hazardous Locations

KMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display

Baymaster HL LED Luminaire High Bay for Hazardous Locations

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display

5 yr. Station Level Paging Adapter. Model 300PBX-SC LINKS TELEPHONE TO SELECTONE OR PUBLIC ADDRESS SYSTEM. dedicated extension

Call/Talk. GAI-Tronics Call/Talk communication systems. GAI-TRONICS A Hubbell Company

FIREFLY FIREBLADE RADIO REMOTE CONTROL SYSTEMS. Applications

PRO Professional Radio Control Series Applications

Fuzzy Temperature Controllers E5AF

LA-5000 SERIES LINEAR VALVE ACTUATORS

DST-2000C. Direction Sensing Tachometer INSTRUCTION MANUAL

FMR ELSEMA 2-Channel 151MHz Receiver - FMR15102

WARNING! IMPORTANT NOTICE

MICROWAVE LEVEL SWITCH OPERATION MANUAL

ELECTRO-MECH SCOREBOARD CO. SL-230 / 330 RF MODEM INSTALLATION MANUAL

Page/Talk Hazardous Area Paging Amplifier

Rosemount 3101, 3102, and 3105

Instruction Manual. Model MLA & MLD Loop Powered Process Indicators IM 61A01A-01E-A. Model MLA (Analog) Model MLD (Digital)

Sultan Radar. Data Sheet. Typical Uses: Typical Features: The New Dimension Radar System. A higher level of performance

Technologies, Solutions, and Applications. Level Switching

REMOTE SENSOR SERIES. Description

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

spy pig Tracking systems

MaxxFlow HTC Flow Measurement for Dry Bulk Solids

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

Abridged Specifications: 10DS3111E/A Sensor with 50SM1000 Transmitter

400W C-Band GaN Compact Outdoor SSPA. 328 Innovation Blvd., Suite 100 2&3 The Matchyns, London Road, Rivenhall End

ACE3 INTELLIGENT BROADBAND AMPLIFIER

MODEL AT-10 ANALOG TRANSMITTER

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

SPECIAL SPECIFICATION 6004 Digital Card Rack Inductive Loop Detector Assembly

Bulletin 800H Hazardous Location Push Buttons Product Overview/Specifications. Table of Contents See below.

Accutech GP10. Wireless gauge pressure field unit

Sultan. Sonar System. Data Sheet. A Higher Level of Performance. Sludge and Submerged Interface Level Measurement.

Industrial Area Crossing Signal System

UltraFlo UFDD ULTRASONIC CLAMP-ON FLOW METER

KMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm)

Signet 9950 Dual Channel Transmitter

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents

PROFLY / PROBLADE Professional Radio Control PRO-BLADE8

ES Series Features Detecting distance twice that of conventional

Digital conductivity transmitter

AC GHZ INTELLIGENT BROADBAND AMPLIFIER

Transcription:

Flow Detection MDS Integral or Remote Housing Microwave Doppler Switch Solids - Chute and Conveyor.525 GHz Sender Receiver FUNCTION Flow/no flow detection in solid material handling applications such as feeder chutes and conveyor systems. TYPICAL USES Product detection on belt conveyor systems Product discharge detection on stackers Coal feeder monitoring - Power stations Grain feeder monitoring Aggregate feeder chute monitoring Conveyor/transfer chute monitoring Machine/conveyor motion detector AUSTRALIAN DESIGNED & M A N U FA C T U R E D

Serial No. MXXXXXXX RECEIVE SENSITIVITY 4 MICROWAVE PULSE RECEIVER 1 LD1 - POWER RV1 APPLIED ON LD2 - SIGNAL DETECTED LO HI 0.3 4-30 sec (A=B) LD3 - RELAY ENERGISED AFTER 1 OFF LO HI 0.3-30 sec RELAY NORM REV AC FUSE P R S T 0mA U V W FROM TO MPS MPS A CTIVE N EUTRAL E ARTH EARTH +24V DATA SHEET PRINCIPLE OF OPERATION The Hawk MDS series microwave doppler flow switch was developed for use in process applications requiring highly reliable non-contact product flow detection. The system operates by sending out bursts of microwave energy toward the target product being monitored. The target product will reflect some of the microwave energy back to the MDS system where it is processed to determine if the product is flowing. The MDS system uses the Doppler principle to determine if the product is moving by monitoring small charges in the reflected signal frequency. When product flow is detected, a timer is initiated and after the user set time-out period, the relay output is switched. The system also has adjustable sensitivity to compensate for products that may partially reflect the microwave energy. The SPST relay can be set to either energise or de-energise when product flow is detected. Three LED indicators are provided to indicate power, flow detection, and relay energised status. The system is available in either an integral or remote housing and is powered by 115Vac, 240Vac or 24Vdc. The system is housed in a FM listed NEMA 4X housing and is mounted using the standard 3 inch NPT weldment or flange. FEATURES Flow/No Flow detection Maximum range capability: 5m (15ft) No site licensing required Low cost installation and cabling Versatile power supply: 115Vac (240Vac also available), 24 Vdc (standard) Excellent adjustment stability for maximum repeatability Super bright LED annunciation for power, microwave signal established, and relay condition Compact integral construction Meets Class 2 Div. 1, E, F, & G specifications Water tight, dust tight, chemically resistant NEMA 4X enclosure Sealed O-ring enclosure Stainless captive screws Baked enamel coating Sealed switch selectable failsafe relay Pre-drilled for convenient access for conduit entry Single turn thumbwheel adjustment potentiometers Push-to-test curcuit 0m sec. to 30 sec. time delays Multiple mounting options (NPT, remote flange etc.) Flush mounted sensor face Robust (high vibration resistance) U.H.M.W. (polythylene) wear plate (standard) High temperature remote mounting with waveguides (contact factory) *See specifications (Range) Flow Detector Flowing Solids/Powders APPLICATIONS ProductMovement Detection Conveyor Moving product on conveyors Coal Feeder Conveyor Moving product on conveyors Product flow movement detection MDA MPR-0

MDS DOPPLER FLOW SYSTEM Sensitivity 'A' Pot L.E.D. Indicators Green - Power Red - Signal Amber - Relay EMI Indicator Sensitivity 'B' Pot (TS3) Terminals (TP5) Positive (TP6) Gnd RV1 (A=B) RECEIVE SENSITIVITY LO LO P R S T RX HI HI Serial No. MXXXXXXX MDA MICROWAVE PULSE RECEIVER AC FUSE 0mA CTIVE LD1 - LD2 - LD3 - EUTRAL ARTH A N E POWER APPLIED SIGNAL DETECTED RELAY ENERGISED AFTER EARTH +24V 1 1 0.3 0.3 RELAY NORM REV 4 4 Serial Number On Delay Off Delay ON -30 sec OFF Test Switch -30 sec P = OV (Black) S = Rx Sig (Blue) T = Remote Rx Power (Red) (Remote Version only) 0mA Fuse (F1) U = OV (Black) V = Tx Sig- (Blue) = Remote Tx Power (Red) Relay mode W EXTEND CABLE BELDEN #9512 (Max. 50 metres) TS1 To remote RX/TX Module (Remote Versions only) AC Supply Active 115/240Vac Neutral Earth Ground RelayTerminals (TS2) Normally Closed Common Output Contact Normally Open DC Supply +24V (Hot) Earth Ground } TS1 Remote RX/TX Module Polyester coated steel MDR 1" BSP Nipple 3" N.P.T. NOTE: Maximum cable length including extention is 50 metres.

DIMENSIONS Remote Microwave Doppler System - Remote Amplifier (MDA) 4 x 5.0mm holes 25.5mm (1") 61.5mm (5.4") Remote Microwave Doppler System - Remote Sensor (MDR) Integral Microwave Doppler System (MDI) 3" N.P.T. 160mm (6.3") 135mm (5.25") 85mm (3.35") 145mm (5.7") 160mm (6.3") 135mm (5.25") 137mm (5.4") 25.5mm (1") 61.5mm (5.4") 61.5mm (5.4") 25.5mm (1") 145mm (5.7") 61.5mm (5.4") 25.5mm (1") 170mm (6.8") Polyester coated mild steel pipe 3" N.P.T. 1" BSP nipple 135mm (5.25") 160mm (6.3") UHMW Window 130mm (5") 192mm (7.6") 135mm(5.25") 160mm(6.3") 4 X Ø22.0 holes thru equi spaced on 241 P.C.D. 130mm (5.15") 3mm (12.2")

Input Voltage: 240Vac nominal, 200-270Vac acceptable, 50-60 Hz 115Vac nominal, 0-130Vac acceptable, 50-60 Hz AC supply line fuse: 0mA, 250Vac Units have terminals for 24Vdc supply power. Power Consumption: <3VA Power Density: Rated from emitter at approximately 20µW/cm 2. Complies with FCC Title Rules Part 15. Caution sign posting not required. Transmitted Signal: Frequency:.525 GHz, ±25 MHz Average Power Density: 20µW/cm 2 typical Linearly Polarised Field Beam angle (3dB) approximately 30 o (conservative) Range: Maximum range under ideal conditions: Expected maximum practical range: Minimum range under ideal conditions: Expected minimum practical range: m (33 ft.) 5m (16 ft.) 0cm (0 in) 1cm (0.4 in) Note: Ranges are dependent on application reflectivity. L.E.D. Indicators: Power on (green) Signal detect (red) Relay state (amber) EMI indicator (red) Mounting: 1. 3" male NPT thread or four 6mm (0.25 in.) blind bolt holes in flange a) 3" weldments supplied for standard integral mounting b) Flange is used for remote mount in high vibration applications-isolation shock mounts are available 2. 4" weldments with PTFE (teflon) and UHMW windows 3. Ceramic window assemblies 4. Firebrick window assemblies available on custom basis 5. 2" NPT sight glass window 6. Flanged Pipe Mount. SPECIFICATIONS Adjustments: Test switch - momentary push-button Single turn coarse and single turn fine adjustment potentiometers for set point. Relay time delays adjustable from 0ms to 30 seconds via two independent on/signal make and off/signal break potentiometers with automatic reset. Fail-safe: Switch selectable - presence or absence of material flow High level fail-safe position: relay is activated when flow is present Low level fail-safe position: relay is activated when no material flow is present Temperature: -30 o C to +65 o C (-20 o F to +150 o F) Note: for higher temperature applications, remote mounting with windows is necessary. Custom waveguide assemblies can also be provided. UHMW Window: Consult factory for manufacturer's specifications. Firebrick Assemblies: Consult factory for manufacturer's specifications. Cabling Entry: 3 x mm (3/8" NPT) Relay Contact Output: SPDT - amps @ 250Vac resistive amps @ 125Vac resistive Enclosure: NEMA 4X. IP67/IP66 SAA LISTED Meets Class 2, Div 1, Group E, F & G (DIP- Dust Ignition Proof) classification. FM Approval Pending Sealing: NEMA 4X Shipping Weights: 4.5kg (lb)

PART NUMBERING MODEL MDS-I = Integral Microwave Doppler Switch System MDS-R = Remote Microwave Doppler Switch System (Sensor and Amplifier) MDS-S = Remote Microwave Doppler Switch - Sensor only MDS-A = Remote Microwave Doppler Switch - Amplifier only SUPPLY VOLTAGE 240 = 240Vac Note: 24Vdc standard on all units 220 = 220Vac 115 = 115Vac OUTPUTS 0 = Standard Relay outputs 6 = Solid State relay outputs FACIAL MATERIAL 0 = UHMW Polyethlene 1 = PTFE (Teflon) Z = Special Request MOUNTING ACCESSORIES 1 = 2" Glass Window 2 = 4" Glass Window 3 = 3" UHMW Window 4 = 4" UHMW Window 5 = 6" UHMW Window 6 = 3" PTFE Window 7 = 4" PTFE Window 8 = 6" PTFE Window 9 = 9"x 4.5" Firebrick = 6"x 4" Ceramic 11 = Isolation Shock Mounts (pack of 4) 12 = Adjustable Mount-UHMW 13 = Adjustable Mount-PTFE 15 = Flange Pipe Mounting 16 = 3" Ceramic Window 17 = 4" Ceramic Window X = Not Required MDS R - 240-0 0 - X Hawk Measurement Systems 15-17 Maurice Court Nunawading 3131 Victoria Australia Represented by: Telephone: 61 3 9873 4750 Facsimile: 61 3 9873 4538 Measurement Systems E-mail Address: hawksales@hawk.com.au ADDITIONAL PRODUCT WARRANTY AND APPLICATION GUARANTEES UPON REQUEST. TECHNICAL DATA SUBJECT TO CHANGE WITHOUT NOTICE. HMS6/99