No mark Time-limit contact 1c Time-limit contact 2c,Time-limit contact A 1c+Instantaneous contact 1c(selectable) DIN W48 H48mm (4digit)

Similar documents
No mark Time-limit SPDT (1c) A Time-limit DPDT (2c) B Time-limit SPDT (1c), Instantaneous SPDT (1c) S DIN W48 H48mm.

Multi Function Timer with Free power, Compact size W38 H42mm

Indicator (4digit) (5digit) 8-pin plug counter

И М. 2 24VAC 50/60Hz, 24-48VDC VAC 50/60Hz

Opaque materials of Min. Ø60mm. Hysteresis - Max. 10% at rated setting distance

No mark VAC 50/60Hz, VDC 1 12VDC 2 24VAC 50/60Hz, 24VDC. selectable by output operation mode

TA Series. Analog And Non-Indicating Type, PID Control, Set Temperature By Dial. Features. Ordering Information TA S B 4 R P 4 C

DIN W48 H24mm, W72 H36mm Loop powered digital scaling meter [M4NS/M4YS Series]

New 1. Temperature unit P J K R. N Indicator. X 12-24VDC VAC 50/60Hz. Indicator Alarm/Sub output. I Indicator

Analog Timer TTL Series

M4Y/M4W/M5W/M4M Series

No-mark 12-24VDC X 1. Multi-input mode. DIN W72 H36mm DIN W96 H48mm (5digit) D Display Unit

Solid-State Digital Counter H7AN

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

Solid-state Timer H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A

Diameter ø50mm Shaft type Absolute Multi-turn Rotary Encoder

T3S/ T3H/ T4M/ T4L. Digital switch setting type. Features. Ordering information T 3 S B 4 R P 4 C

High Reliability Of Fiber Optic Amplifier For Convenient Mounting

12 V DC ±10 % 150 ma max. 130 ma max. 120 ma max.

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

Count/Time Totalizers

DIN48 SIZE MULTI-RANGE ANALOG TIMER. Protective construction. Time range IP65 IP50 IP selectable ranges 1s to 500h IP50 IP65 IP50

Solid-state Twin Timer

Timers GT3F. GT3F Series True Power OFF Delay Timers. Phone: Fax: Web: -

TA Series. Analog And Non-Indicating Type, PID Control, Set Temperature By Dial. Features. Ordering Information TA S B 4 R P 4 C

High Speed Response Type With Built-in Output Protection Circuit

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range 13.

Solid-state Timer H3DE

High Speed Response Type With Built-in Output Protection Circuit

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

DIN48 SIZE ANALOG MULTI-RANGE CYCLIC TWIN TIMERS

Solid-State Timer. ON-delay, Repeat cycle/signal OFF start, Repeat cycle/signal ON start, Signal ON/OFF-delay, Signal OFF-delay, and Interval

Bulletin 700-HX Multifunction Digital Timing Relay

Self-Powered Counters H7ET

Solid-state Timer H3DS

Power supply voltage Output Timer function Features Model No Single-function with one input/output (two circuits)

Area sensor with plastic case

Self-powered Counter

For more information, please visit or call toll free at

WHEN A PLC IS TOO MUCH, AND SPACE FOR

Digital Counter. DIN 72 x 72 mm Counters with Easy-to-use Functions

Ratchet Relay. Ordering Information. Unique Ratchet Mechanism Assures Positive Alternate Transfer/Switching Operation. G4Q-jjjj

Timers GE1A. GE1A Series ON Delay Timers Single Function

DIN 48 SIZE DIGITAL TIMER. UL File No.: E C-UL File No.: E122222

Communication Ethernet communication (TCP/IP) 8 8mm 16 16mm 25 25mm W. White R. Red G. Green. Blue M G V. Effective focal length

TA Series. Analog Setting Non-Indicating type, PID Control. Analog and non-indicating type, PID control, set temperature by dial.

COMPACT SIZE HIGH PRECISION TIMERS VARIOUS OUTPUT & OPERATION MODE TYPES. UL File No.: E CSA File No.: LR39291

OMRON. H3DE - Standard Timer. H3DE-G - Star-Delta Timer. H3DE-F - Twin Timer. H3DE-H - Power OFF- Delay Timer

ELECTRONIC COUNTER (with pre-scaling function) UL File No.: E C-UL File No.: E122222

SLIM COMPACT SAFETY RELAY

Cylindrical type proximity sensor

Section. Timers. Selection Guide... G-2. Timing Diagrams Overview... G-4. W G RTE Series Analog Timers... G-8 Accessories... G-11 Dimensions...

Solid-state Timer. Operation/resetting system Time-limit contact Time ranges Model

OFF-delay time. 7.5 s. 15 s. 30 s. Main contacts Auxiliary contact Number of input channels Rated voltage Model Category

PARM-SIZED, 16-CHANNEL RELAY TERMINALS

LA-T SERIES. Fast and reliable minute granular flaw detection in winding wires. Winding Wire Granular Flaw Detector PARTICULAR USE SENSORS

EE-SX770/771/772/870/871/872(A/P/R)

Select G3PA SSRs and G32A Cartridges to be Discontinued; Replace with G3PA-X or G3PJ Relays, G32A-A-X Cartridges

Weekly Timer. ON/OFF and cycle operations up to one week Two SPST-NO time limit contacts with manual override switches

Two outputs: contact and non-contact

Switching & Controls Timers

Y Type. W Type. AC voltage AC current

E2C-EDA. Proximity Sensor with Separate Amplifier Enables Easily Making Highprecision Sensitivity Settings. Ordering Information

MULTI-RANGE ANALOG TIMER

Remote Sensor Amplifier Terminal

Timing Mode Supply Voltage Trigger Options Reset Options Outputs Cat. No V AC Power On Power Off. Repeat Cycle OFF-Start

Fuzzy Temperature Controllers E5AF

Model Number Structure

Capacitive Proximity Sensor

Solid-state Timer H3DE

RT-3 UNIT RELAY 4-POINT TERMINAL

Digital Panel Meter. Ordering Information. Subminiature Digital Panel Meter that Accepts DC Input. Accessories (Order Separately)

DIN 22.5/17.5 Size Lineup of A Wide Range of Measuring and Monitoring Relays. Model Number Structure

THT TYPE. Interface unit with built-in DO module FEATURES

Slim compact safety relay

GE Series. Model and Suffix code. Power Supply. Dimensions & Panel Cutout DANGER

0.01kV (0 to ±0.99 kv)

NPN PNP NPN PNP NPN PNP

2.1 General Specifications

Sensing method Through-beam Retroreflective Diffuse reflective Convergent-beam Appearance Side-view Flat Side-view Flat Side-view

Ordering Information. Latching Relay MMK. Available Models. Models Conforming to Auxiliary Power Relay Specifications

Electronic timers CT-S range Selection and ordering details

Model Number Structure

PCB Relay. Ordering Information. SPST-NO Type Breaks 10-A Loads; SPST-NO + SPST-NC Type Breaks 8-A Load

Monitoring voltages of 3-phase 4 wires with a single unit

RT-3 UNIT RELAY 4-POINT TERMINAL

Ultraminiature Photoelectric Switches with Self-contained Amplifier

Basic Composition. Merits. Presettable/Read-out Counter for High-speed Addition and Subtraction. Electronic. Counters. Maximum operating speed

T ime Delay Relays General information

onlinecomponents.com

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

Power supply voltage Output configuration Output code Resolution (pulses/rotation) Connection method Model

Solid-state Timer H3DS

Solid-state Timer H3DS

Count - counters 5. Selection guide 5 XBK T81030U33E RC XBK RC XBK T60000U00M XBK T60000U11M XBK T80000U00M XBK T70000U00M 5/2

DIN 48 SIZE DIGITAL TIMER. UL File No.: E C-UL File No.: E122222

Class II. Sensing method Appearance Connection Sensing distance Output function Model method NPN output PNP output mm.

Rated time Time setting range Time division 1 week 00:00 a.m. to 11:59 p.m. 1 min

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range 13.

Transcription:

DIN W48 H48mm Digital backlight LCD timer Features Upgraded Features Mounting space saving with compact design : downsized by approx. % in depth compared to existing ls (length of panel on the back side is 56mm) Available to set each value and time range separately when choosing Flicker(FK, FK I) or ON-OFF Delay(ON OFF D, ON OFF D I) output Adds Flicker (LE4SA) Settable One-shot output time(. to 99.99sec.) (existing l: fixed.5 sec.) Configurable time range (added 9.999sec.): Settable by.sec. unit Selectable min. input time: ms or ms (LE4S) Improved return time: ms Backlight ON/OFF function Original Features Wide time range(.sec. to 9999hour) Lock setting function for saving setting data Soft touch setting High visibility display with backlight Ordering information LE 4 S K- Item Specifications Model LE4S LE4SA Function Multi time and Multi operation method LCD display(backlight) supply 4-4VAC 5/6Hz, 4-4VDC universal Allowable voltage range 9 to % of rated voltage consumption 4-4VAC: Max. 4.5VA, 4-4VDC: Max. W 4-4VAC: Max. 4VA, 4-4VDC: Max..6W Return time Max. ms Min. input signal INHIBI RESE ms, ms(selectable) - No-voltage input Input INHIBI RESE Impedance at short-circuit : Max. kω, Residual voltage : Max..5V, Impedance at open-circuit : Min. kω - iming operation Signal ON Start ON Start Control output Digit Size Output No mark ime-limit contact c ime-limit contact c,ime-limit contact A c+instantaneous contact c(selectable) S DIN W48 H48mm 4 9999(4digit) Please read Caution for your safety in operation manual before using. LE LCD imer Sockets (PG-8, PS-8, PS-M8) are sold separately. Contact type ime limit SPD(c) Selectable ime limit DPD(c), ime limit SPD(c)+ Instantaneous SPD(c) (depends on operation ) Contact capacity 5VAC 5A resistive load 5VAC 3A resistive load Relay Mechanical Min.,, operations life cycle Electrical Min., operations (at rated contact capacity) Output operation s 8 operation s Environ Ambient temperature - to 55, storage: -5 to 65 -ment Ambient humidity 35 to 85%RH Accessory Bracket Environment resistance is rated at no freezing or condensation.

LCD imer(ouch ype) Specifications Model LE4S LE4SA Repeat error Setting error Voltage error emperature error Insulation resistance Dielectric strength Noise strength Mechanical Vibration Malfunction Mechanical Shock Malfunction Max. ±.% ±.5sec.( ON Start) Max. ±.5% ±.3sec.(Signal ON Start) Max. ±.% ±.5sec. MΩ(at 5VDC megger) VAC 5/6Hz for minute ±kv the square wave noise(pulse width: μs ) by the noise simulator.75mm amplitude at frequency of to 55Hz(for min.) in each of X, Y, Z directions for hour.5mm amplitude at frequency of to 55Hz(for min.) in each of X, Y, Z directions for minutes 3m/s² (approx. 3G) in each of X, Y, Z directions for 3 times m/s² (approx. G) in each of X, Y, Z directions for 3 times (A) Photo electric (B) Fiber optic (C) Door/Area (D) Proximity (E) Pressure (F) Rotary encoder (G) Connector/ Socket Approval Unit weight Dimensions Approx. 98g (H) emp. (I) SSR/ 48 6 7 56 Panel cut-out Min. 65 (J) Counter (K) imer 44.8 56 Min. 65 45 +.6 45 +.6 (L) Panel (M) acho/ Speed/ Pulse (N) unit (O) Bracket and mounting (P) Switching power supply (Q) Stepper motor& Driver&Controller Insert product into a panel, fasten bracket by pushing with tools as shown above. (R) Graphic/ Logic panel (S) Field network device () Software (U) Other K-

Connections LE4S RESE 4 5 3 6 CONAC OU: 5VAC 5A RESISIVE LOAD INHIBI 8 7 (ime limit contact c) - + SOURCE 4-4VAC 5/6Hz 4-4VDC LE4SA [ON.D] [ON.D.II] [FK] [FKI] [IN] [] [.I] 4 5 3 6 7 CONAC OU: 5VAC 3A RESISIVE LOAD (Instantaneous (ime limit contact c) contactc) 8 (ime limit contact c) - + SOURCE 4-4VAC 5/6Hz 4-4VDC ime limit contact c + Instantaneous contact c or ime limit contact c (Selectable) ([] [.I] : ime limit c only.) [ - ] 4 5 3 6 CONAC OU: Contact 7 Contact 5VAC 3A RESISIVE LOAD (ime limit contact a) (ime limit contact a) 8 - + SOURCE 4-4VAC 5/6Hz 4-4VDC K-

LCD imer(ouch ype) Input connections LE4S is No-voltage input(short-circuit and open) type. Solid-state input Contact input (A) Photo electric (B) Fiber optic Q -4VDC LE4S -4VDC LE4S LE4S + + RL - - RESE RESE RESE S INHIBI Q INHIBI S INHIBI S3 Input V Input V Input V (C) Door/Area (D) Proximity (E) Pressure Q is ON : Operating : NPN open collector output Q is ON : Operating : NPN universal output Be sure that it is not insulated between power and input terminal block. S, S, S3 are ON : Operating Please use reliable contact enough to flow 5VDC ma. (F) Rotary encoder (G) Connector/ Socket Parts description Output display It displays the status of output contact. ime progressing display It displays the current time. ime unit It displays the time unit. (h:hour)(m:min.)(s:sec.) When the time is progressing, it is flashing at a rate of (.5sec.) ime setting display It displays the setting time. (H) emp. (I) SSR/ (J) Counter (K) imer (L) Panel (M) acho/ Speed/ Pulse / It displays time progressing ( ), ( ). Operation It displays the current operation. (ex: OND=ON Delay) (N) unit (O) Key lock display It displays the status of lock. RESE Used for initializing time progressing and output return. SHIF Used for advancing to setting time change and moving to each digit. Used for advancing to function setting, setting time change checking. MODE Used for changing the set value. (P) Switching power supply (Q) Stepper motor& Driver&Controller (R) Graphic/ Logic panel (S) Field network device () Software (U) Other K-3

Function and time setting Configuration On Reset Setting time change RUN for 3sec. while pressing Function setting for 3sec. Checking output contact status If changing function setting, operation will stop. LE4SA only. : Enabled : Disabled Reset Reset using in Run Run he operation status(when power is on for the first time : factory default setting) is displayed. It could enter into function setting, setting value change and output contact status. Function setting If pressing over 3 sec. in the Run, it will enter into function setting and if pressing over 3 sec. in function setting, it will return to Run. Even if it enter into function setting in Run, time progressing and output control will continue. If operation settings are changed in function setting, all outputs will be off and reset on returning to run. Output contact status (LE4SA only) Output contact status are displayed while pressing in Run. If pressing over 3 sec., it will enter into function setting. Setting time change Press to enter into setting time change and press to return to Run. Even if signal is input when changing setting time, time progressing and output control will be continue. If no is pressed over 6 sec. in setting time change, it will return to Run. If no is pressed over 6 sec. in setting time change, it will return to Run and previous para value is not stored. K-4

LCD imer(ouch ype) Function setting LE4S Function setting )ime range (A) Photo electric (B) Fiber optic RUN [OND], [ONd], [ONd], [IN], )Output operation [INt], [OFD] 3)One-Shot output time 3sec. 3sec. 7)Key lock 6)Backlight On/Off [FLK], [FLk], [NFD], [NFd] 5)Min. input signal toffime range ONd ton ime range 4)ime Up/Down (C) Door/Area (D) Proximity (E) Pressure (F) Rotary encoder (G) Connector/ Socket (H) emp. LE4SA Function setting (I) SSR/ (J) Counter RUN 3sec. 3sec. )Output operation 7)Key lock 6)Backlight On/Off [OND], [ONd], [IN] [FLK], [FLk] [S-D], [WN], [Wm] 5)Min. input signal )ime range toff ime range ime range ONd 3)One-Shot output time ton ime range ime range 4)ime Up/Down (K) imer (L) Panel (M) acho/ Speed/ Pulse (N) unit (O) (P) Switching power supply (Q) Stepper motor& Driver&Controller (R) Graphic/ Logic panel Factory default LE4S Para Factory default Output operation OUtM OND ime range trng 9(99 ime Up/Down U-D Min. input signal In Backlight On/Off BLU ON Key lock LOCK loff Setting time - 5) LE4SA Para Factory default Output operation OUtM OND ime range trng 9(99 ime Up/Down U-D Output contact CON cc Backlight On/Off BLU ON Key lock LOCK LOc Setting time - 5) (S) Field network device () Software (U) Other K-5

Output operation LE4S/LE4SA output operation NO Operation LE4S LE4SA OND ON Delay ONDⅠ ON Delay - 3 ONDⅡ ON Delay 4 FK Flicker 5 FKⅠ Flicker 6 IN Interval 7 INⅠ Interval - 8 ON OFF D ON-OFF Delay - 9 ON OFF DⅠ ON-OFF Delay - OFF D OFF Delay - - SAR-Delay - win - 3 Ⅰ win - Output operation ) In function setting, it enter into output operation as shown in the [Fig. ]. ) Select proper output operation using and. (Refer to Output operation flowchart) 3) Press to set output operation and move to next. 4) If pressing for 3 sec. in any function setting, it will return to Run. [Fig.] Output operation flowchart < LE4S > OND ONd ONd FLK FLk OFD NFd NFD INt IN < LE4SA > OND ONd FLK FLk Wn WN S-D IN he shaded para( ) is factory default. K-6

LCD imer(ouch ype) ime Range ime range specifications toff time range ton time range time range time range Para ime range specification s (9.999s).sec. to 9.999sec. s (99.99s).sec. to 99.99sec. s (999.9s).sec. to 999.9sec. s (9999s) sec. to 9999sec. m s (99m59s) msec. to 99min. 59sec. m (999.9m).min. to 999.9min. m (9999m) min. to 9999min. h m (99h59m) hmin. to 99hour 59min. h (99.99h).hour to 99.99hour h (999.9h).hour to 999.9hour h (9999h) hour to 9999hour ime range according to output operation -ime range[trng] : OND, ONd, ONd, IN, INt, OFD - toff/ton time range[ofrg/onrg] : FLK, FLk, NFD, NFd - / time range[!rg/@rg] : S-D, WN, Wn (A) Photo electric (B) Fiber optic (C) Door/Area (D) Proximity (E) Pressure (F) Rotary encoder (G) Connector/ Socket (H) emp. (I) SSR/ (J) Counter (K) imer (L) Panel (M) acho/ Speed/ Pulse ime range selection method (N) unit [Fig.] ime range flowchart When OND, ONd, ONd, IN, INt, OFD ) In function setting, if it enter into time range, the characters will be displayed as shown in the [Fig. ]. ) Select the time range using and. (Refer to time range flowchart) 3) Press to complete the time range setting and the next. 4) If pressing for 3 sec., it will return to Run. When FLK, FLk, NFD, NFd, S-D, WN, Wn time range[!rg, @RG or OfRG, OnRGcan be individually set. (O) (P) Switching power supply (Q) Stepper motor& Driver&Controller (R) Graphic/ Logic panel (S) Field network device 99.99s 999.9s 9999s 99m59s 999.9m () Software (U) Other 9.999s 9999h 999.9h 99.99h 99h59m 9999m he shaded para( ) is factory default. K-7

One-shot output time setting When output operation ON Delay [ONd], ) In function setting, if it enter into One-shot output time setting as shown in the [Fig. ], the last digit will flash. ) Set One-shot output time using and.(setting range:.s to 99.99s) 3) Pressing to complete one-shot output time setting and move to the next. 4) If pressing for 3 sec. in any function setting, it will return to Run. [Fig.] Factory default ime progress / setting ) In function setting, if it advances to / setting, the characters will be displayed as shown in the [Fig. 3]. ) Select ( ), DN( ) using,. [Fig.3] Factory default 3) Press to complete / setting and move to the next. 4) If pressing for 3sec. in any function setting, it will return to Run. he minimum input signal setting(le4s only) RESE, and INHIBI. ) In function setting, if it enter into input signal setting, the characters will be displayed as shown in the [Fig. 4]. ) Select ms or ms using, s. [Fig.4] Factory default 3) Press to complete input signal width and move to the next. 4) If Pressing over 3 sec. in any function setting, it will return to Run. Output contact setting(le4sa only) ) In function setting, if it enter into output contact setting, the characters will be displayed as shown in the [Fig. 5]. )Select time limit c+instant limit c or time limit c using, s. (Refer to LE4SA Connections on K- page for output contact connections) [Fig.5] Factory default 3) Press to complete output contact setting and move to the next. 4) If pressing for 3 sec. in any function setting, it will return to Run. Except for Star-Delta, win and win s(c is set automatically) If pressing in Run, output contact setting value will be displayed. (If no is pressed over 3 sec., it will enter into function setting.) K-8

LCD imer(ouch ype) Backlight ON/OFF setting ) In function setting, if it enter into Backlight ON/OFF setting, the characters will be displayed as shown in the [Fig. 6]. ) Select Backlight ON or OFF using,. (A) Photo electric (B) Fiber optic (C) Door/Area [Fig.6] Factory default Key Lock setting [Fig.7] Factory default 3) Press to complete Backlight ON/OFF setting and move to the next. 4) If pressing for 3 sec. in any function setting, it will return to Run. ) In function setting, if it enter into Key Lock setting, the characters will be displayed as shown in the [Fig. 7]. ) Select loff, LOc, LOcor LOc3 using,. loff Blank urns off the Lock. cannot be used. Function urns off the Lock. LOc cannot be used. LOc, cannot be used. LOc3,, cannot be used., cannot be used.,, cannot be used. 3) Press to complete lock setting and move to the next. 4) If pressing for 3 sec. in any function setting, it will return to Run. Factory default for LE4S is loff and Factory default for LE4SA is LOc. Key Lock function (D) Proximity (E) Pressure (F) Rotary encoder (G) Connector/ Socket (H) emp. (I) SSR/ (J) Counter (K) imer (L) Panel (M) acho/ Speed/ Pulse (N) unit Setting time change Please set operation time according to following instruction as the setting is different depending on the output operation. Output operation : OND, ONDⅠ, ONDⅡ, IN, INⅠ, OFF D (LE4SA does not have no ONDⅠ, INⅠ, OFF D.) (O) (P) Switching power supply (Q) Stepper motor& Driver&Controller (R) Graphic/ Logic panel (S) Field network device () Software [Fig.] [Fig.] [Fig.3] [Fig.4] [Fig.5] ) Press in RUN, time set digits will flash.[fig. ] ) Change setting time by using or.[fig.,3,4] - : Shift the setting digits. - : Shift the flashing position value. As press once, it will increase by digit, number will increase faster by press for over sec. 3) When the setting is completed, it will be stored and return to RUN by pressing.[fig. 5] (U) Other K-9

Output operation : FK, FK I Run Setting of toff time Setting the time Setting of tontime Setting the time Run Output operation : ON OFF D, ON OFF D I(LE4S only) Run Setting of OnD time Setting the time Setting of OFfD time Setting the time Run Output operation : -,, I (LE4SA only) Run Setting of - time Setting the time Setting of - time Setting the time Run It is able to change the setting time during the time progressing, but be sure about the time progressing while changing of the time. If pressing while setting time is shorter than min. setting time, setting value will be flickering three times and it will be returned to setting again, not to RUN. If there is no additional operations in 6 sec. after entering into setting, it will be return to RUN. (set value is not stored.) Min. setting time :. sec. (In case of : OND, ONd, ONd s, it is able to set "" since no min. setting time is applied.) K-3

LCD imer(ouch ype) LE4S Output operation = Setting time, > a Mode ime chart Operation [OND] a OND RESE 3 OU 4 ON Delay OU. iming operation starts when signal is ON at status of power on.. Output will be ON when timing operation is progressed up to the setting time. value will be HOLD. ( position) 3. When RESE signal is ON, display value and output will be reset.( position) > a 4. If RESE signal is OFF while signal is ON, SEP will be restarted.(3 position) = set time 5. When signal is OFF, display value and output will be reset.(4 position) [ONd] a ONDⅠ RESE 3 OU RESE ON Delay. iming operation starts when signal is ON at status of power on. OU. Output will be ON when timing operation is progressed up to the setting time. value will be HOLD.( position) > a 3. Even though signal is applied repeatedly, only the initial signal is recognized.( position) = set time 4. When RESE signal is ON, display value and output will be reset.(3 position) [ONd] a a ONDⅡ RESE OU ON Delay (One-shot output) > a [FLK] FK Flicker (off operation precedes) on, off > a [FLk] FK. Ⅰ Flicker (on operation precedes) on, off > a. iming operation starts when signal is ON at status of power on.. ime limit output will be ON and goes OFF during out setting time when timing operation is progressed up to the setting time. value will be HOLD.( position) 3. When RESE signal is ON, display value and output will be reset. 4. If signal is applied while time is progressing, iming operation will be reset and started again. ( position) 5. out setting range:. sec to 99.99 sec. off on off a off a off on a off on RESE OU off on off on off on off on. If is ON, output will be repeatedly OFF during off setting time and will be OFF during on signal OU setting time when power is ON.. When RESE signal is ON, display value and output will be reset. on, off = set time 3. If RESE signal is OFF when signal is ON, SEP will be restarted. Enables to set on and 4. When signal is OFF, display value and output will be reset. off time differently. 5. It is able to set each off time and on time separately. In [ ], timing operation starts with off. on off on off a on off a on a on RESE OU off on off on on off on OU. IF signal is ON, output will be repeatedly ON during on setting time and will be OFF during off setting time when power is ON.. Even though signal is applied repeatedly, only the initial signal is recognized.( position) on, off = set time 3. When signal is ON, display value and output will be reset. If signal is ON, it will be Enables to set on and restarted. off time differently. 4. It is able to set each off time and on time separately. In [ ], timing operation starts with on. Initial status : -display value is "", output is "OFF". -display value is "setting time", output is "OFF". OU out = output time = set time out (A) Photo electric (B) Fiber optic (C) Door/Area (D) Proximity (E) Pressure (F) Rotary encoder (G) Connector/ Socket (H) emp. (I) SSR/ (J) Counter (K) imer (L) Panel (M) acho/ Speed/ Pulse (N) unit (O) (P) Switching power supply (Q) Stepper motor& Driver&Controller (R) Graphic/ Logic panel (S) Field network device () Software (U) Other K-3

K-3 LE4S Output operation Mode ime chart Operation [IN] IN Interval > a [INt] INⅠ Interval > a [NFD] ON OFF D ON-OFF Delay > a [NFd] ON OFF DⅠ ON-OFF Delay > a [OFD] OFF D OFF Delay > a RESE OU. Output will be ON when signal is ON at status of power on and iming operation starts.. Output will be OFF when timing operation is progressed up to the setting time. value will be HOLD. 3. When RESE signal is ON, display value and output will be reset.( position) 4. If RESE signal is OFF when signal is ON, SEP will be restarted. 5. When signal is OFF, display value and output will be reset.( position) a RESE OU. Output will be ON when signal is ON at status of power on and iming operation starts.. Output will be OFF when timing operation is progressed up to the setting time. value will be HOLD. 3. Even though signal is applied repeatedly, only the initial signal is recognized.( position) 4. If signal is ON after timing operation is progressed up to the setting time, Output will be ON and setting time will be reset and then timing setting starts. 5. When RESE signal is ON, display value and output will be reset.( position) RESE OU off on off on on off a a. If signal is ON when power is on, Output will be ON when timing operation is progressed up to the on setting time(on-delay). IF signal is OFF, output will be ON when timing operation is progressed up to the off setting time (OFF-Delay).. If signal is applied repeatedly, output is ON and display value will be reset.( position) 3. When RESE signal is ON, display value and output will be reset. When RESE signal is OFF while signal is ON, it will be operating as On-Delay.( position) 4. It is able to set each off time and on time separately. on off a a off a on a on off RESE OU off on off on. If signal is ON when power is on, timing operation starts. Output will be ON when timing operation is progressed up to the on setting time(on-delay). IF signal is OFF, output will be ON when timing operation is progressed up to the off setting time (OFF-Delay).. Output will be ON when signal is ON and goes OFF during setting time and display value will be reset.( position) 3. Output will be OFF when signal is OFF and goes ON during setting time and display value will be reset.( position) 4. When RESE signal is ON, display value and output will be reset. When RESE signal is OFF while signal is ON, it will be operating as On-Delay.( position) 5. It is able to set each off time and on time separately. RESE OU = Setting time, > a Initial status : -display value is "", output is "OFF". -display value is "setting time", output is "OFF". off a a on a a a. If signal is ON when power is on, output will be ON.. When signal is OFF, timing operation starts. Output will be OFF when timing operation is progressed up to the setting time. value will be HOLD. 3. When RESE signal is ON, display value and output will be reset. a on off OU = set time OU = set time OU OU OU on on on, off = set time on, off = set time = set time off off

LCD imer(ouch ype) LE4SA Output operation = Setting time, > a, Rt = Reset time Mode ime chart Operation [OND] Rt OND RESE ime limit contact (8-6) Instantaneous contact (-3) ime limit contact ON Delay output [ONd] ONDⅡ ON Delay (One-shot output) [FLK] FK Flicker (off operation precedes) on, off > a [FLk] FKⅠ Flicker (on operation precedes). iming operation starts when power is ON.. ime limit output will be ON when timing operation is progressed up to the setting time. value will be HOLD. 3. If selecting time limit c + instantaneous c, instantaneous output will be ON when power is ON and goes OFF when power is OFF. 4. If pressing RESE, display value and time limit output will be reset. RESE ime limit contact (8-6) Instantaneous contact (-3) Rt. iming operation starts when power is ON.. ime limit output will be ON during out setting time and goes OFF when timing operation is progressed up to the setting time. value will be HOLD. 3. If selecting time limit c + instantaneous c, instantaneous output will be ON when power is ON and goes OFF when power is OFF. 4. If pressing RESE, display value and time limit output will be reset. 5. out setting range:. sec to 99.99 sec. RESE ime limit contact (8-6) Instantaneous contact (-3) off on off on a Rt off off off off off on on on on. Control output will be repeatedly OFF during off setting time and will be ON during on setting time when power is ON.. If selecting time limit c + instantaneous c, instantaneous output will be ON when power is ON and goes OFF when power is OFF. 3. If pressing RESE, display value and time limit output will be reset. 4. It is able to set each off time and on time separately. In [ ], timing operation starts with off. RESE ime limit contact (8-6) Instantaneous contact (-3) off on off on off a Rt on on on on off on off off. Control output will be repeatedly ON during on setting time and will be OFF during off setting time when power is ON.. If selecting time limit c + instantaneous c, instantaneous output will be ON when power is ON and goes OFF when power is OFF. 3. If pressing RESE, display value and time limit output will be reset. 4. It is able to set each on time and off time separately. In [ ], timing operation starts with on. Initial status : -display value is "", output is "OFF". -display value is "setting time", output is "OFF". Instantaneous contact(ou) will be returned when power is off. RESE is locked for default set and release the lock to use. = set time ime limit contact output ime limit contact output out = output time = set time out off on off on on, off = set time Enables to set on and off time differently. ime limit contact output on off on off on, off = set time Enables to set on and off time differently. (A) Photo electric (B) Fiber optic (C) Door/Area (D) Proximity (E) Pressure (F) Rotary encoder (G) Connector/ Socket (H) emp. (I) SSR/ (J) Counter (K) imer (L) Panel (M) acho/ Speed/ Pulse (N) unit (O) (P) Switching power supply (Q) Stepper motor& Driver&Controller (R) Graphic/ Logic panel (S) Field network device () Software (U) Other K-33

LE4SA Output operation Rt : Reset time(min. 5ms) Mode ime chart Operation [ IN ] RESE ime limit contact (8-6) Instantaneous contact (-3) Rt Interval. ime limit output will be ON when power is ON and iming operation starts.. ime limit output will be OFF when timing operation is progressed up to the setting time. value will be HOLD. 3. If selecting time limit c + instantaneous c, instantaneous output will be ON when power is ON and goes OFF when power is OFF. 4. If pressing RESE, display value and time limit output will be reset. [ ] Rt - RESE contact(8-6) ime limit contact output = set time Star-Delta (Output will be set automatically contact(-3) as ime limit c). contact will be ON when power is ON and iming operation starts.. contact will be OFF when timing operation is progressed up to the setting time. iming operation will be reset and started again. 3. contact will be ON when timing operation is progressed up to the switching time. value will be HOLD. 4. If pressing RESE, display value and - contacts will be reset. 5. It is able to set each and time separately. [ ] Rt RESE contact(8-6) contact contact : set time : switching time ( - switching time) win (Output will be set automatically as ime limit c) contact(-3). contact will be ON when power is ON and iming operation starts.. contact will be OFF and contact will be ON when timing operation is progressed up to the setting time. iming operation will be reset and started again. contact will be OFF when timing operation is progressed up to the setting time. value will be HOLD. 3. If pressing RESE, display value and, contacts will be reset. 4. It is able to set each and time separately. [ ] a Rt Ⅰ RESE contact(8-6) contact contact, = set time Enables to set and time same or differently win (Output will be set automatically as ime limit c) contact(-3). iming operation starts when power is ON.. contact will be ON when timing operation is progressed up to the setting time. iming operation will be reset and started again. 3. contact will be ON when timing operation is progressed up to the setting time. value will be HOLD. 4. If pressing RESE, display value and and contacts will be reset. 5. It is able to set each and time separately. contact contact, = set time Enables to set and time same or differently Initial status : -display value is "", output is "OFF". -display value is "setting time", output is "OFF". Instantaneous contact(ou) will be returned when power is off. RESE is locked for default set and release the lock to use. K-34

LCD imer(ouch ype) Proper usage Caution It may give an electric shock if touch the input signal terminal(between, RESE, INHIBI and terminal ) when the power is supplied. connection Connect AC power line between (-7) for LE4S, LE4SA AC power type. Be careful of power connection for DC power type. (, 7 ) LE4S, LE4SA work stably within range of rated power. (If using power line with another high voltage line or energy line in the same conduit, it may cause inductive voltage. herefore please use seperate conduit for power line) start Caution for power rising time(ms) after power on and power falling time(ms) after power off. ON OFF ms he unstable time against the input signal ms ON Start LE4SA l is starting after ms of supplying the power due to rising time of other devices (, etc.) (refer to the above figure.) For ower ON Start, under ms setting may cause unstable operation. (it operates normally over ms setting) For using under ms time operation, use LE4S, Signal ON Start type. Supply the power at once by a switch or relay contact, otherwise it may cause timing error. Input/Output terminal and Input terminal have not been insulated because there is no power transformer in this imer. When using the of SSR output type with input terminal of timer, please check whether Double insulated or not. Please use double insulated relay when connecting relay output with input terminal. Please use 8 Pin socket when connecting this imer with other equipment and do not touch the socket when power on. Please use supply with over current protection circuit.(5v A fuse) When using relay contact as input signal, please use a contact that can function reliable at 5VDC, ma. In case of connecting terminal (3) and power terminal () of LE4S, do not use it to start at the same time applying power. LE4S is transformer less type, therefore please check following for connecting relay contact for input signal and transistor. When connecting more than timers with relay contact for input or transistor, please wire following <Fig. >. Please use relay contact or transistor to start. (ime error can occurs under ms setting because of rising time of imer). Input contact or transistor Shortcircuit current Input contact or transistor Main circuit LE4S 3 RESE 4 INHIBI LE4S 3 RESE 4 INHIBI LE4S 3 RESE 4 INHIBI LE4S 3 RESE 4 INHIBI < Fig. > Please use transfomer with primary and secondary isolated for input. LE3S 3 RESE 4 INHIBI Rectification ransformer circuit with isolation < External power supply > Be sure that the specifications of this unit. Because when supplying the power to LE4SA, this unit operates instantly. (If supplying the power without the right checking, it may cause malfunction.),, operation s are available to set as "". (A) Photo electric (B) Fiber optic (C) Door/Area (D) Proximity (E) Pressure (F) Rotary encoder (G) Connector/ Socket (H) emp. (I) SSR/ (J) Counter (K) imer (L) Panel (M) acho/ Speed/ Pulse (N) unit (O) (P) Switching power supply (Q) Stepper motor& Driver&Controller (R) Graphic/ Logic panel (S) Field network device () Software (U) Other K-35

Interval It is able to make Instantaneous ON and time limit OFF (Holding device) with using interval. : imer ime limit Instantaneous ime limit Load LE4S Load <Previous> <Interval > Change of output operation and timer range If changing output operation or time range,previous reset value will be deleted. But, / selection and lock are exception. Change of preset value If changing setting value while time progressing, new preset value should be higher than previous preset value. Otherwise output may work while changing setting value. If changing setting value while it is running, it will work as changed setting value. Please use lock function in order to avoid malfunction. Noise We test kv, pulse width μs against Impulse voltage between power terminals and kv, pulse width μs at noise simulator against external noise voltage. Please install MP condensor (. to μf ) or oil condensor between power teminals when over impulse noise voltage occurs. Environment Please avoid the following places; Where this product may be damaged by strong impact or vibration. Where there are corrosive gas or flammable gas and water, oil, dust exist. Where magnetic and electrical noise occurs. Where there are high temperature and humidity beyond rated specification. Where there are strong alkalis and acids. Where there are direct rays of sun. K-36