Is Higher Resistance Better?

Similar documents
Model Channel Cryogenic Temperature Monitor

Model 325 Temperature Controller

240 Series. Cryogenic Temperature Sensor Input Modules. 240 Series modules are the ideal companion to Cernox

TEMPERATURE CONTROLLER

Model 335. Temperature Controller

Model 332 Temperature Controller

Model 350. Temperature Controller

Model 350 Temperature Controller

Model 372 AC Resistance Bridge and Temperature Controller

Cryogenic Temperature Controllers Model 32/32B

Model 32/32B. Major highlights of the Model 32:

Model 340 Temperature Controller

Includes Coverage For:

Temperature Sensor Calibration Files page 1

Curve Handler Basic Operation

PRECISION TEMPERATURE SYSTEMS. Compact Modular and Upgradeable Thermometry Measurement Systems

Model 325. Temperature Controller. User s Manual

Model 176 and 178 DC Amplifiers

Cryogenic Temperature Controller Model 42/44

6. LDD Design Tradeoffs on Latch-Up and Degradation in SOI MOSFET

Precision in Practice Achieving the best results with precision Digital Multimeter measurements

MeasureReady M91/M91-T FastHall Measurement Controller

A New Standard for Temperature Measurement in an Aviation Environment. Hy Grossman

UT-ONE Accuracy with External Standards

A Noise-Temperature Measurement System Using a Cryogenic Attenuator

Bend Sensor Technology Mechanical Application Design Guide

Solution: Based on the slope of q(t): 20 A for 0 t 1 s dt = 0 for 3 t 4 s. 20 A for 4 t 5 s 0 for t 5 s 20 C. t (s) 20 C. i (A) Fig. P1.

Bondable Resistance Temperature Sensors and Associated Circuitry

SIGNAL CONDITIONING FOR CRYOGENIC THERMOMETRY IN THE LHC

Application Note #AN-00MX-002

Lab 1: Basic Lab Equipment and Measurements


Webinar Organizers. Ryan Shea. Don Miller. Joe Ryan. Support Specialist. Applications Specialist. Product Manager. Precision Digital Corporation

Lake Shore Cryotronics Application Note. Temperature

LM134/LM234/LM334 3-Terminal Adjustable Current Sources

Calibration Coefficients and Thermistor Selection

Resistance Temperature Detectors (RTDs)

Cost Effective Techniques used to Validate the Performance of the microk Resistance Thermometry Instrument with sub mk Uncertainty

SNA Calibration For Use In Your Shack

MeasureReady 155 Precision I/V Source. An ultra-low noise, high-precision current/voltage source for scientific and other demanding applications

electrical noise and interference, environmental changes, instrument resolution, or uncertainties in the measurement process itself.

IC Preamplifier Challenges Choppers on Drift

A CONTAINER FOR ELECTRICAL NOISE: ULTRAGUARD THEORY AND PRACTICE

Temperature References for Highest Accuracy Industrial Thermocouple Measurements

Copyright 1997 by the Society of Photo-Optical Instrumentation Engineers.

1. A transducer converts

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

WFC3 TV3 Testing: IR Channel Nonlinearity Correction

An Evaluation of Artifact Calibration in the 5700A Multifunction Calibrator

Discover. Blue Box. the. Difference. High Resistance Metrology Products Guide

Resistance Value. Interloop capacitance. reduction. in series. Mutual inductance. reduction. due to change in current direction

INA126. MicroPOWER INSTRUMENTATION AMPLIFIER Single and Dual Versions IN ) G V IN G = 5 +

Model 234. Model 234D

Simulation comparisons of monitoring strategies in narrow bandpass filters and antireflection coatings

AMP-13 OPERATOR S MANUAL

Precision INSTRUMENTATION AMPLIFIER

Model 6625T Series TEMPERATURE MEASUREMENT SYSTEMS

EXPERIMENTAL ERROR AND DATA ANALYSIS

Tel: Fax:

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

LMC7660 Switched Capacitor Voltage Converter

Includes Coverage For: Model Silicon Diode Model Platinum Resistor Model Thermocouple

Conductance switching in Ag 2 S devices fabricated by sulphurization

Signal Conditioning Fundamentals for PC-Based Data Acquisition Systems

Discover the. Blue Box. Difference. Electrical and Temperature Metrology Products Guide

Model 6622T Series. DCC Thermometry Bridges 6622T SERIES FEATURES

SWITCHED CAPACITOR VOLTAGE CONVERTERS

A Low Noise GHz Amplifier

CYC325, CYC325-T1, CYC325-T2

discovery in 1993 [1]. These molecules are interesting due to their superparamagneticlike

How to Evaluate PV Project Energy Yield

Chapter 4. Single-Supply Op Amp Design Techniques. Excerpted from Op Amps for Everyone. Literature Number SLOA076. Literature Number: SLOD006A

ni.com Sensor Measurement Fundamentals Series

Using the Normalized Image Log-Slope, part 2

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

EDC Lecture Notes UNIT-1

Multimeter Selection Guide Fluke 8508A & Agilent 3458/HFL

Guide for Choosing Resistors that are Exposed to Different Stresses

6. Resistor Colour Code

NOVEMBER 28, 2016 COURSE PROJECT: CMOS SWITCHING POWER SUPPLY EE 421 DIGITAL ELECTRONICS ERIC MONAHAN

IS31AP4066D DUAL 1.3W STEREO AUDIO AMPLIFIER. January 2014 KEY SPECIFICATIONS

Temperature Controller

INAB Policy Statement on Scope Format for Calibration Laboratories PS27 1. INTRODUCTION

Technical Note. HVM Receiver Noise Figure Measurements

Figure 1 Basic Mode Comparison


Precision VOLTAGE REFERENCE

Microprocessor based process control

PRODUCT DESCRIPTION. Using Allegro Current Sensors in Current Divider Configurations for Extended Measurement Range

Single-channel power supply monitor with remote temperature sense, Part 1

Sensor-Emulator-EVM. System Reference Guide. by Art Kay High-Precision Linear Products SBOA102A

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Measuring the Power Dissipation Capability of High-Voltage, Low-Capacitance Ceramic Chip Capacitors

"Improve Instrument Amplifier Performance with X2Y Optimized Input Filter"

MODEL 5002 PHASE VERIFICATION BRIDGE SET

The Importance of Data Converter Static Specifications Don't Lose Sight of the Basics! by Walt Kester

As delivered power levels approach 200W, sometimes before then, heatsinking issues become a royal pain. PWM is a way to ease this pain.

New Materials and Method for Laser Trimmable NTC Thermistors

LMC7660 Switched Capacitor Voltage Converter

MODEL INFORMATION. AccuBridge Model 6010D. Automated Primary Resistance/ Thermometry Bridge

Transcription:

Negative Temperature Coefficient Temperature Sensors: Is er Resistance Better? For low temperature thermometry, negative temperature coefficient (NTC) temperature sensors such as germanium, Cernox, and ruthenium oxide (Rox ) can provide tremendous sensitivity and resolution. While the resistance as a function of temperature characteristic is somewhat fixed for a given model of Rox temperature sensors, it can vary greatly for germanium RTDs where fabrication is accomplished through bulk doping during crystal growth and for Cernox where fabrication is accomplished through thin film deposition. For both germanium and Cernox RTDs there is a common misconception that a higher resistance equates to a better sensor. This is a somewhat ambiguous statement, but for the purposes of this discussion, better sensor is interpreted as better resolution or better accuracy (i.e., lower uncertainty). This application note addresses the question Is higher resistance better? for NTC temperature sensors. Instrumentation It is important to understand that concepts of resolution and accuracy are largely meaningless if applied only to the temperature sensor. These concepts become meaningful only when discussed in the framework of the electronics that are used to measure their resistance. While the physical construction of the sensor may limit the allowable excitation power to avoid or minimize self-heating, it is ultimately the electronic resolution and electronic accuracy of the instrument that determines the temperature resolution and temperature accuracy of the overall measurement. Even then, the electronic resolution and accuracy will depend upon the resistance range and excitation power level. As temperature decreases below 20 K, the thermal conductivity of the materials used to construct temperature sensors decreases rapidly, thus limiting the thermal connection of the sensor to its environment. This requires that the power dissipated in the sensor be decreased as temperature is decreased to avoid self-heating the sensor. For NTC temperature sensors it is common to operate them at constant voltage over large portions of their temperature range. Since the resistance increases as temperature decreases, the power dissipated in the sensor decreases with temperature as required for an NTC device operated in this manner. For a germanium, Cernox, or Rox RTD, a nominal 10 mv excitation voltage works well over the temperature range spanning 1.4 K to room temperature. In reality, however, the voltage is not constant. Virtually all cryogenic temperature controllers and monitors operate as constant current sources. Even when the excitation is set in terms of voltage, the instrument provides a constant current related to V Set /R Range. On a given resistance range, this means that the true excitation voltage signal, V Exc, varies from 0 V to V Set and it equals V Set only at full scale on that resistance range. Obviously, when the resistance drops too low for one resistance range, the instrument should switch to the next lower resistance range. This requires an increase in current to keep the ratio V Set /R Range nearly constant. The overall result is an excitation voltage signal that is sawtooth-shaped with drops occurring where the resistance range changes occur. As an example, consider a model CX-1050 with resistance and sensitivity as a function of temperature shown in Figure 1. The measurement instrument is a Lake Shore el 340 temperature controller with a nominal excitation of 10 mv from 1.4 K to 325 K. Specifications for this controller are in the Lake Shore product catalog or at www.lakeshore.com. The el 340 temperature controller resistance ranges have upper limits of 30 Ω, 100 Ω, 300 Ω, 1kΩ, 3 kω, 10 kω, 30 kω, 100 kω and 300 kω, and it is assumed that the CX-1050 temperature sensor is measured on the lowest resistance range that can be used. Then the excitation current, I Exc, is given by V Set /R Range where V Set =10 mv. The actual excitation voltage is given by V Exc = I Exc, R Meas where R Meas is the measured temperature dependent resistance of the sensor. Figure 2 shows the actual voltage excitation and power dissipation as a function of temperature for the sample CX-1050-SD. Notice that as the resistance range changes the voltage excitation and power dissipation abruptly change resulting in the saw tooth shape of each curve. The resistance range for each segment of the two curves is labeled. The nominal 10 mv excitation is achieved only at full scale on a given resistance range. Lake Shore Cryotronics, Inc. 575 McCorkle Boulevard Westerville, Ohio 43082 1

10 6 10 6 10 5 10 5 Sensitivity Resistance (Ω) Resistance Sensitivity (Ω/K) 10 0 1 3 6 0 60 100 400 Figure 1. Resistance and sensitivity as a function of temperature for a model CX-1050-SD temperature sensor. 10-1 1 10-5 300 Ω 100 Ω 10-6 Excitation Voltage (V) 0.1 0.01 300 kω 100 kω 30 kω 10 kω 3 kω 1kΩ Power Dissipation 10-7 10-8 10-9 Power Dissipation (W) 10-10 Nominal 10 mv Excitation Voltage 0.001 1 3 6 0 60 100 400 Figure 2. Voltage excitation and power dissipation for a sample CX-1050-SD measured with a Lake Shore el 340 temperature controller with nominal 10 mv excitation. 10-11 Lake Shore Cryotronics, Inc. 575 McCorkle Boulevard Westerville, Ohio 43082 2

1000 Resolution (mk) 100 10 1 0.1 300 kω 100 kω 30 kω Accuracy 10 kω 3 kω Resolution 1kΩ 300 Ω 100 Ω 0.01 0.001 1 3 6 0 60 100 400 Figure 3. Measurement resolution and accuracy for a sample CX-1050-SD measured with a Lake Shore el 340 temperature controller using a nominal 10 mv excitation. Just as the power dissipation depends upon the set excitation level and resistance range, so do both the resolution and accuracy (uncertainty) of the measurement as shown in Figure 3. Again, the resistance range for each segment of the two curves is listed. Also notice that while the sensitivity of the CX-1050 continues to increase rapidly at the lowest temperatures, the best temperature resolution occurs around 3.5 K on the 30 kω scale, demonstrating that the measurement can become more difficult to perform when the resistance is too high or two low. Another complication is that as the sensor resistance changes due to changing temperature, it may be undesirable to change from 100% range on one scale to 30% range on the next adjacent scale (or vice versa depending on whether temperature is increasing or decreasing.) In the best case, this could simply result in an annoying or unanticipated change in power dissipation, resolution, and accuracy. In the worst case, this could create an unstable control temperature if the resistance at the control temperature lies at the boundary of two ranges, causing the controller to constantly switch ranges while controlling at that temperature. To avoid this, most instruments are purposely designed to have some overlap between ranges. The downside is that in automatic mode the instrument may switch resistance ranges at different percentages of full range, depending upon whether resistance is increasing or decreasing. In these cases, the only way to truly know the resistance range and consequently the power dissipation, resolution and accuracy is to query the instrument. Sensor Resistance With an understanding of the instrumentation, the question remains as to whether higher resistance with its associated higher sensitivity implies better resolution and accuracy for an NTC temperature sensor. Resistances that are too high (greater than a few hundred kilohms) or too low (less than 10 ohms) are more difficult to measure than resistances that lie between the two extremes. Instrument specifications can degrade as either extreme is approached. This portion of the discussion will examine the resolution and accuracy for low, moderate, and high resistance sample Cernox sensors. The labeling refers to the resistance at the lowest temperature for which each Cernox model is designed to be useful (0.1 K for CX-1010 and 1.4 K for CX-1030)., moderate, and high resistance is somewhat arbitrary and is a tradeoff between being high enough to give reasonable resolution, but not too high as to be difficult to measure. For remainder of this discussion low resistance refers to 5 kω, moderate resistance refers to 50 kω, and high resistance refers to 100 kω. The actual resistance and sensitivity values for each sensor used in this analysis are plotted in Figures 4 and 5. Lake Shore Cryotronics, Inc. 575 McCorkle Boulevard Westerville, Ohio 43082 3

10 5 Resolution (mk) CX-1030 CX-1050 0.06 0.1 0.3 0.6 1 3 6 0 60 100 400 Figure 4. Resistance as a function of temperature for sample low, moderate, and high resistance CX-1010s and CX-1030s used in this analysis. 10 7 Sensitivity (Ω/K) 10 6 10 5 CX-1030s CX-1050s 10 0 10-1 10-2 0.06 0.1 0.3 0.6 1 3 6 0 60 100 400 Figure 5. Sensitivity as a function of temperature for sample low, moderate, and high resistance CX-1010s and CX-1030s used in this analysis. Lake Shore Cryotronics, Inc. 575 McCorkle Boulevard Westerville, Ohio 43082 4

As pointed out before, the concepts of resolution and accuracy are meaningless without the details of the instrumentation used to perform the measurement. In these two examples, the CX-1010 is measured using a Lake Shore el 370 AC resistance bridge while the CX-1050 is measured using a Lake Shore el 340 temperature controller. Specifications for both are available in the Lake Shore product catalog or at www.lakeshore.com. Based upon each individual sensor s response curve and the instrument specifications, the temperature resolution and accuracy was computed for each sample. The results are given in Tables 1 and 2 for the CX-1010 measured using the Lake Shore el 370 and in Tables 3 and 4 for the CX-1050 measured using the Lake Shore el 340. The best values are back-shaded in each table to help guide the eye. Note that the electronic temperature uncertainty listed in Tables 2 and 4 do not include calibration uncertainty. Table 1. Temperature measurement resolution for low, moderate, and high resistance CX-1010 RTDs measured with a Lake Shore el 370. Excitation level is listed. The best values are back shaded to guide the eye. Excitation Temperature Resolution (mk) 0.1 20 μv 0.013 0.014 0.028 0.3 63 μv 0.025 0.016 0.011 0.5 200 μv 0.025 0.0077 0.0059 1 630 μv 0.11 0.015 0.013 4.2 6.3 mv 0.021 0.037 0.039 20 6.3 mv 0.22 0.14 0.16 50 6.3 mv 0.69 0.46 0.55 77.35 6.3 mv 0.40 0.83 0.33 150 6.3 mv 0.95 0.67 0.85 300 6.3 mv 2.7 2.0 2.7 Table 2. Total temperature uncertainty due to electronic measurement error for low, moderate, and high resistance CX-1010 RTDs measured with a Lake Shore el 370. Excitation level is listed. The best values are back shaded to guide the eye. Excitation Electronic Temperature Uncertainty (mk) 0.1 20 μv 0.037 0.015 0.085 0.3 63 μv 0.16 0.11 0.088 0.5 200 μv 0.25 0.15 0.12 1 630 μv 0.55 0.48 0.42 4.2 6.3 mv 3.4 3.3 3.1 20 6.3 mv 22 18 17 50 6.3 mv 54 42 43 77.35 6.3 mv 63 67 51 150 6.3 mv 118 96 98 300 6.3 mv 264 209 232 As seen in Tables 1 and 2 for CX-1010s measured using a Lake Shore el 370 AC resistance bridge, the best resolution varies among all three resistance ranges with the upper resistance ranges being slightly better while the best temperature uncertainty is split between the moderate and high resistance ranges with the high resistance range being slightly better. The same is mostly true for the CX-1050s measured with a Lake Shore el 340 shown in Tables 3 and 4. Lake Shore Cryotronics, Inc. 575 McCorkle Boulevard Westerville, Ohio 43082 5

Table 3. Temperature measurement resolution for low, moderate, and high resistance CX-1050 RTDs measured with a Lake Shore el 340. Excitation level is listed. The best values are back shaded to guide the eye. Excitation Temperature Resolution (mk) 1.4 10 mv 0.013 0.030 0.12 4.2 10 mv 0.096 0.052 0.032 20 10 mv 0.79 0.22 0.21 50 10 mv 1.1 1.3 1.6 77.35 10 mv 2.3 0.93 1.1 150 10 mv 2.4 3.3 4.1 300 10 mv 8.6 4.6 5.4 Table 4. Total temperature uncertainty due to electronic measurement error for low, moderate, and high resistance CX-1050s RTDs measured with a Lake Shore el 340. Excitation level is listed. The best values are back shaded to guide the eye. Excitation Electronic Temperature Uncertainty (mk) 1.4 10 mv 0.64 0.46 1.3 4.2 10 mv 4.0 2.5 1.8 20 10 mv 30 15 13 50 10 mv 56 52 58 77.35 10 mv 98 59 65 150 10 mv 144 143 166 300 10 mv 375 253 287 In this case, the moderate resistance range gives the best temperature uncertainty. In addition, at a particular temperature, the resistance range that gives the best resolution does not even necessarily give the best accuracy. The main reason for the variation in the best sensor is that the higher sensor resistance forces the instrument to a higher resistance range, and the electronic resistance and accuracy at higher ranges can degrade faster than the sensitivity increases. Three points can be made here. First, the higher sensitivity does not necessarily translate into higher temperature resolution. In fact, in both of these examples, the low resistance samples have a sensitivity 100 times less than the high resistance samples at their lowest operating temperature, yet the low resistance samples give better resolution. Second, the high resistance samples do not necessarily provide the best temperature measurement uncertainty. There is a trend, but it is not absolute. Third, even though the relative sensitivities can differ significantly (two orders of magnitude at the lower temperatures) the differences in resolution and sensitivity are mostly within a factor of 2 among the three resistance ranges at any given temperature. It could be argued that the results from Tables 1 through 4 are skewed by virtue of operating at constant voltage. In this mode, a low resistance sensor would dissipate more power (P=V 2 /R) than a higher resistance sensor. Since using a higher power to measure the resistance usually yields better specifications, this may make the low resistance sensors look better than they are. In fact, this is not the case. Normalizing the measurement power to the moderate resistance sample for all three samples in the group yields results that are reasonably consistent with the results in Tables 1 through 4. Conclusions There are many instrumentation subtleties that affect low temperature thermometry measurements, including the excitation mode and how the instrument switches between resistance ranges. Ultimately the excitation level and resistance range determine the electronic resolution and accuracy, which in turn determine the temperature resolution and accuracy. Since for a given NTC thermometer type higher resistance implies higher sensitivities, it would be expected that the higher resistance thermometers should yield better resolution and accuracy. As demonstrated, this is not the case in general. The best sensor in terms of temperature resolution and accuracy is somewhat random in that it depends on which resistance range the instrument is forced to operate. Overall, the low resistance samples perform as well as the high resistance samples and the differences that do occur are generally less than a factor of two. Copyright Lake Shore Cryotronics, Inc. 2007 Last modified 6/8/2007 6