USER MANUAL. Multi Field EMF Meter. Model EMF Washington Street Melrose, MA Phone Toll Free

Similar documents
RF EMF Strength Meter

RF EMF Strength Meter

RF EMF Strength Meter

ELECTROSMOG METER INSTRUCTION MANUAL

RF EMF Strength Meter

Triple Axis RF/High Frequency Meter HF-B3G. User s Manual HB4HFB3G0000

Pro Triple Axis RF/High Frequency Meter HF-B8G. User s Manual HB4HFB8G0000

8GHz RF EMF Strength Meter

RF three-axis Field Strength Meter TM-196

Model E201. Wide Range RF Field Strength Meter

Model E200 3-Axis RF Field Strength Meter

Instruction Manual. IM Axis RF Field Strength Meter

USER MANUAL. UV AB Light Meter. Model UV505. Additional User Manual Translations available at

Magnetic Field Meter EM-191

USER GUIDE. White LED Light Meter. Model LT Washington Street Melrose, MA Phone Toll Free

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

Instructions for the TES 593 RF Meter

RF/High Frequency Meter HF-A3G

3 AXIS RF ELECTROMAGNETIC FIELD METER

Microwave Meter. Instruction Manual

USER MANUAL. Laser Distance Meter MODELS DT40M, DT60M, and DT100M

netzerotools.com USER GUIDE Extech LT40 LED Light Meter Extech LT45 Color LED Light Meter LED Light Meter Model LT45 netzerotools.

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

Micro-Ohmmeter Model UM200

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

USER MANUAL. LUX/FC Light Meter. Model LT505. Additional User Manual Translations available at

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

User Guide. AC/DC Mini Clamp Meter. Model

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

Model True RMS AC/DC 30A Mini Clamp-on Meter. User Guide

USER GUIDE. IR Thermal Scanner. Model IRT500

400Amp True RMS AC Clamp Meter + NCV

R/C SMD Tweezers Multimeter Model RC200

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

User's Guide. Pinless Moisture/Humidity Meter with IR Thermometer + Bluetooth. Model MO297

Wireless AC Circuit Identifier

User s Guide. Model MA A AC Mini Clamp-on Meter

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

User's Guide. EasyView Light Meter with Memory. Model EA33. Introduction

Laser Distance Finder Extech DT500

Compact MultiMeters + Voltage Detector

4100 Series ELF Gauss/Tesla Meter

Mini Clamp Meter Model:

v1.0.1 March AlphaLab, Inc. All rights reserved. TriField EMF Meter Owner s Manual

TENMARS TM-195. RF three-axis Field Strength Meter. User's Manual HB2TM

Printing Humidity/Temperature Meter

Manual FA505. Field Analyzer FA505. Users Manual Version 1.0.

User Guide. EasyView Digital Light Meter. Model EA31

AMM-1022 Digital Multimeter USER`S MANUAL

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

Laser Distance Finder Extech DT500

INTRODUCTION. 4 SAFETY INSTRUCTIONS. 5 ABOUT THIS DEVICE. 6 FIRST OPERATION. 7 THE DISPLAY. 8 ATTACHING THE WRIST SLEEVE. 9 CORRECT MEASUREMENT.

ACA LEAKAGE TESTER OPERATION MANUAL. auto range, true rms. Model : DL-9954

Controls. LCD display A B C D E F

User Guide. Digital AC/DC Clamp Meter Model 38394

Visit us at

Multi-Channel In-Out Thermometer with Cable Free Sensor and RF Clock

User s Guide. Digital AC/DC Clamp Meter Model 38394

Monitoring electric and magnetic fields

Model: TP380 User Manual

EasyView Light Meter with Memory

User Guide. 4 wire Earth Resistance Tester Model GRT Washington Street Melrose, MA Phone Toll Free

User Manual InfraRed Thermometer With Laser Pointer and High/Low Alarms Model IR270

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

Model: &

400Amp True RMS AC/DC Clamp Meter Model EX613

Wireless Copilot. Safe2Fly - Height Only Version. Page NanoQuip Ltd

Wireless Color Weather Station

Not for print. Microphone Test Device with SONNET MTD Adapter. User Manual. Cochlear Implants NOT FOR PRINT

OPERATIONS MANUAL. narda MODEL 8513 INDUSTRIAL COMPLIANCE METER. for Electromagnetic Energy. Safety Test Solutions. P/N Rev B

Pair of PMR446 Two-Way Personal Radios Model: TP391

USER'S MANUAL DMR-6700

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

User s Manual. Ground Resistance Clamp On Tester MODEL

Monitoring electric and magnetic fields

Important safety instructions

Carbon Monoxide (CO) and Carbon Dioxide (CO 2 ) Meter With Air Temp/RH Measurements and Dew Point/Wet Bulb calculations

PIN/PINLESS DEEP SENSING MOISTURE METER WITH SPHERICAL SENSOR AND REMOTE PROBE

IOSH Webinar. Control of Electromagnetic Fields at work regulations 2016 Part 2 EMF exposure assessment 4 th May 2017 Julia Clark FSRP CMIOSH

Field Analyzer FA735 Users Manual

Monitoring electric and magnetic fields

LCR METER Model:

600 AAC Clamp Meter Instruction Manual

RF and Microwave Power Sensors/Meters Tektronix PSM3000, PSM4000, and PSM5000 Series Data Sheet

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

INSTRUCTION MANUAL Vibration Meter

CLAMP-ON METER 670. User Manual

200Amp AC Clamp Meter + NCV Model MA250

ATOMIC WALL CLOCK with REMOTE TEMPERATURE SENSOR Model CL Instruction Manual

A WORLD OF LISTENING WARNING: TO PREVENT FIRE OR ELECTRIC SHOCK HAZARD, DO NOT EXPOSE THIS PRODUCT TO RAIN OR MOISTURE.

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

Transcription:

USER MANUAL 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Multi Field EMF Meter Visit us at www.testequipmentdepot.com Model EMF450

Safety Information CAUTIONS Before making a measurement, check if the low battery symbol is shown on the display when the meter is switched on. Replace the battery if the symbol is displayed. In the case of prolonged storage, remove the battery from the meter to prevent damage. Do not expose this device to direct sunlight or to extreme temperatures and humidity. The accuracy and function of the meter may be adversely affected if the specified limits are exceeded or if the meter is handled improperly. Clean the device with a soft, dry cloth. Moisture can damage the meter. Electric field measurement precautions: Perform tests according to the indicated directions. WARNINGS Use caution when working in the vicinity of powerful radiation sources. Persons with electronic implants (e.g. cardiac pacemakers) should avoid powerful radiation sources. Observe all relevant safety regulations. Carefully read the operating instructions for equipment generating or conducting electromagnetic energy that will be measured. Do not operate near combustible gases or in damp environments. Be aware that the field strength in the near vicinity of radiators increases proportionally to the inverse cube of the distance. This means that enormous field strengths can result in the immediate vicinity of small radiation sources (e.g. leaks in waveguides or inductive ovens). Field strength measurement devices can underrate pulsed signals, particularly with radar signals, in which case significant measurement errors can result. All field strength measuring devices have a limited specified frequency range. Fields with spectral components outside of this frequency range are generally incorrectly evaluated and tend to be underrated. Before using field strength measuring devices be certain that all field components to be measured lie in the specified frequency range of the measuring device. For indoor use; Pollution level II Operating altitude below 2000 (6562 ) 2

Introduction This meter simultaneously measures and displays Magnetic Field, Electric Field, and RF Strength. The unit of measurement and the measurement types are expressed in units of electrical and magnetic field strength and power density. This meter is ideal for EMF measurements of power lines, electrical appliances, industrial devices, cell phones, base stations, and microwave leakage. This device is shipped fully tested and calibrated and, with proper use, will provide years of reliable service. Features Data hold (HOLD) Overload display OL. Brightness options: low medium high Selectable Auto Power off (APO) Time: 1; 3; 5; 10; 15; 30 minutes Key press Sounds / Alarm Sounds: On ; Off with programmable tone selections Information screen shows software version Languages: English, Traditional Chinese, Simplified Chinese, Japanese, Spanish Magnetic units selection:gauss (mg) or Tesla (μt) Electric field strength: V/m RF Strength Units selection: (μw/m² ~mw/m²) (μw/cm²) (m V/m ~V/m) (ma/m) (dbm). Low Frequency EMF Readings: Individual and aggregated XYZ axial readings: High frequency EMF Readings RF Historical Records; up to 20 groups. Low battery indication: HIGH LOW External USB Power Supply: 3

Definitions Electromagnetic Radiation This meter is used to indicate radiated electromagnetic fields wherever there is a voltage, current, electric (E) or magnetic (H) field. Examples include the electromagnetic fields from radio broadcasting, TV transmitters and power lines. Electric Field Strength This is a field vector quantity that represents the force (F) on an infinitesimal unit positive test charge (q) at a point divided by that charge. Electric field strength is expressed in units of volts per meter (V/m). Use the units of electric field strength for measurements in nearfield power measurements. Magnetic field strength (H) This is a field vector that is equal to the magnetic flux density divided by the permeability of the medium. Magnetic field strength is expressed in units of amperes per meter (A/m). This measurement is for near field power measurements. Power density (S) Power per unit area in the direction of propagation; usually expressed in units of watts per square meter (W/m2) or, for convenience, milli watts per square centimeter (mw/cm 2 ). The characteristic of electromagnetic fields Electromagnetic fields propagate as waves and travel at the speed of light (c). The wavelength is proportional to the frequency. λ (wavelength) = c (speed of light) f (frequency) Near field is assumed if the distance to the field source is less than three wavelengths. For far fields, the distance is more than three wavelengths. In the near field, the ratio of electric field strength (E) and magnetic field strength (H) is not constant, so measure each separately. In the far field, however, it is enough to measure one field quantity, and compute the other accordingly. Descriptions Front Panel Description 1. 2.4 Color TFT display (240*320 resolution) 2. Select and Down button 3. Power and Menu button 4. Mini USB interface jack 5. Hold and Enter button 6. Battery compartment cover and measurement chart on back of meter 6 5 Figure 1 Meter Description 4 1 2 3 4

Display description 1. Data Hold 2. Auto power off (APO) 3. Audible alert 4. Battery status 5. USB power 6. Magnetic Field bargraph 7. Magnetic Field digital reading 8. XYZ axes values 9. Electric Field bargraph 10. Electrical Field digital reading 11. RF strength bargraph 12. RF strength histogram display 13. Select 14. Menu 15. Hold / Enter 16. RF electronic field color alert* 17. RF strength digital reading 18. RF Strength indication area 19. LF Electrical field color alert* 20. Electrical field indication area 21. LF electromagnetic field color alert* 22. Magnetic field indication area 22 21 20 19 18 16 17 1 2 3 4 5 Hold 15 14 13 Figure 2 Display Description 6 7 8 9 10 11 12 *Color Coded Alert Table (for reference purpose only) see items 16, 19, and 21 above. Magnetic Fields Electrical Fields RF Strength Low 0~10.00mG 0~500V/m 0~0.99mW/m 2 (0.59V/m) Medium 10.01~100mG 501~1000V/m 1~9.99 W/m 2 (1.9V/m) High 101~2000mG >1001V/m >10 W/m 2 (>2V/m) Note: Alarm beeper sounds when readings enter the red region. Conversions 1W/m² = 0.1mW/Cm² = 100μW/Cm². 1mW/m² = 0.1μW/Cm² 5

Operation Power ON/OFF 1. Press the power button to power the meter. The display will show the main measurement screen. If the meter does not power on, check that the batteries are installed correctly and are fresh (see battery installation/replacement section later in this guide). The EM450 can also be powered from a USB port. 2. Press and hold the Power button for 3 seconds to power off the meter. External USB power supply An icon is displayed when an external USB power supply is connected to the meter s USB jack on the bottom of the meter. Voltage specification is 4.7~5.2VDC with current greater than or equal to 500mA. USB cables should not reach over the top rim of the buttons during testing since the EMF450 will recognize this cable as an antenna causing the readings to be inaccurate. Data hold (HOLD) Press the HOLD button to freeze the current readings on the display. The HOLD display icon will appear when this mode is active. To release the data press the HOLD button again. Electric Field Measurements The EM450 measures the electric field (Electrical Power) in the atmosphere of the sensor s surroundings. The sensor orientation is printed on the back of the meter. Perform all tests according to the indicated direction of the electric field sensor. Hold the meter at the bottom and at arm s length, as shown in Figure 3. Figure 3 Orienting the meter for Electrical Field Measurements 6

Low Frequency EMF Readings (Magnetic field) Point the front section of the meter toward the desired electromagnetic field to take a measurement. The meter simultaneously displays the electromagnetic field readings of individual (XYZ) and the aggregated Magnetic field readings. The aggregated calculation equation is expressed as: Due to environment related magnetic field factors, this electromagnetic field (EMF) meter may display a reading of under 0.50mG prior to testing. This is caused by the magnetic noise in the environment, rather than meter failure. The Magnetic and Electric field will also display a warning indicator (Good/Normal/Warning). Important: If the sensor is moved quickly, excessive field strength values will be displayed which do not reflect the actual field conditions. This effect is caused by electrostatic charges. Measurement considerations: 1. Hold the meter at arm s length. 2. Point the front face of the meter toward the source of power. 3. Hold the meter steady during the measurement. 4. Make several measurements at various locations in the work place or other areas of interest. This is particularly important if the field conditions are unknown. 5. Pay special attention to measuring the neighboring vicinity for possible radiation sources. Apart from active sources, those components connected to a source may also act as radiators. For example, the cables used in diathermy equipment may also radiate electromagnetic energy. Note that metallic objects within the field may locally concentrate or amplify the field from a distant source. RF strength meter readings Point the front face of the meter toward the desired RF field to take a measurement. The RF signal strength will be displayed with the units of measure set from the menu mode. The RF strength portion of the display will also show a RF strength history histogram and a warning indicator (Good/Normal/Warning) based on the measured value. Measurement considerations: 1. Hold the meter at arm s length. 2. Point the front face of the meter toward the source of power. 3. Hold the meter steady during the measurement. 7

Menu Settings 1. Momentarily, press the center MENU key to enter the main menu. 2. Press the right SELECT key to cycle through the list. 3. Press the left ENTER key to enter the selected option. 4. Use the right SELECT key to choose the desired setting. 5. Press the left ENTER key to confirm the setting, the meter will exit the menu unless there are more settings required for the given parameter (as in the SOUND setting); in which case continue using the keys in the same manner as described in this section. 6. From the Main Menu screen (Figure 4), the MENU key can be used to exit the Main Menu. Figure 4 Main Menu Option Screen Brightness: Low, Middle, High Magnetic unit: Gauss/mG, Tesla/ µt (Used for testing Electrical power (50/60Hz)) RF strength unit: Language: Power OFF (Auto): Sound: Keys: Alarm: Information: µw/m² mw/m², µw/cm², mv/m V/m, ma/m, and dbm (Used for testing RF energy from 50MHz to 3.5GHz) English, Traditional Chinese, Simplified Chinese, Japanese, Spanish NO (OFF), 1, 3, 5, 10, 15, 30 (minutes). Factory default is 5 minutes. Enable/Disable when enable is selected, the keys/alarm sound menu will open. 3 options (1, 2, or 3) represent alternate keystroke sounds. 3 options (1, 2, or 3) represent alternate alarm sounds. Displays the software version 8

Battery Installation and Replacement Battery Installation Remove the rear battery cover and insert three (3) 1.5V AAA batteries observing correct polarity. Figure 5 Battery Installation Battery Replacement The battery status icon shows low energy when the battery voltage drops below the operating level. See installation instructions above for battery insertion. Never dispose of used batteries or rechargeable batteries in household waste. As consumers, users are legally required to take used batteries to appropriate collection sites, the retail store where the batteries were purchased, or wherever batteries are sold. Disposal: Do not dispose of this instrument in household waste. The user is obligated to take end of life devices to a designated collection point for the disposal of electrical and electronic equipment. Other Battery Safety Reminders o Never dispose of batteries in a fire. Batteries may explode or leak. o Never mix battery types. Always install new batteries of the same type. 9

Specifications Sensor Type: LF Magnetic Fields Range: 20mG /200mG /2000mG, 2µT /20µT /200µT Display resolution: 0.02/0.1/1 Frequency range: 50/60Hz Accuracy: ± (15% + 100 digits) Sensor Type: LF Electric Field Sensor Range: Display resolution: Frequency range: Accuracy: Sensor Type: RF Strength Range: Display resolution: Frequency range: Accuracy: 50V/m to 2000V/m 1V/m 50/60Hz ± (7% + 50 digits) 0.02µW/m² to 554.6mW/m² 0.02µW/cm² to 55.4µW/cm² 36.1mV/m to 14.46V/m 0.02mA/m to 38.35mA/m 51dB to 16dBm 0.02µW/m², 0.2µA/m, 0.2mV/m, 0.002µW/cm², 2dB 50MHz to 3.5GHz ± 2dB at 2.45GHz Display: Sample rate: Sensors: Over range condition: Battery: Battery Life: Alarm: Operating temperature and RH%: Storage temperature and RH%: Weight: 4 digits Triple color TFT display 6 seconds Triple axes (XYZ) RF and ELF and Electric field sensor The EM450 is equipped with three individual aerial sensors to measure EMF. Overload indication (OL) applies to all three axes (X, Y, and Z) Three (3) 1.5V alkaline batteries Approx. 8 hours Beeps when readings are in the red display region 5 C~40 C (41 F ~104 F); < 80%RH 10 C to 60 C (14 F ~140 F); < 70%RH Approx. 120g (4.2 oz.) Dimensions: 115 x 60 x 21mm (4.5 x 2.4 x 0.08 ) 10 Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com