Specifications. LF450 /LF610 LF450 /LF612 20" to 24" (500 to 600 mm) Field Intelligent Device Series Electromagnetic Flowmeter. Overall Specifications

Similar documents
Introduction. Specifications LF620,LF622. Field Intelligent Device Series Electromagnetic Flowmeter Converter

Electromagnetic Flowmeter

Specifications ELECTROMAGNETIC FLOWMETER. LF664/LF620 LF664/LF to 78 (500 to 1950mm) Overall Specifications TIC-LF664K

Electro-Magnetic Flowmeters COPA-XE

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

Density (Consistency) Meter LQ500

Flow Measurement SITRANS F M

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

Flow Measurement SITRANS F M

Density (Consistency) Meter

Ambient Conditions. Operating Conditions. Pressure

OPTIFLUX 1000 Technical Datasheet

EGC100W MAGMAX. Converter for Electromagnetic Flowmeter GENERAL FEATURES STANDARD SPECIFICATION. General Specification

TIDALFLUX 2300 F Technical Datasheet

Field IT Electro-Magnetic Flowmeters Mini-Mag with integral XE converter

Flow Measurement SITRANS F M. Transmitter TRANSMAG 2 with sensor 911/E 4/101. Overview

OPTIFLUX 5000 Technical Datasheet

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

LQ510. Density (Consistency) Meter. Introduction. Specifications EJL- 123

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display

Model Sono-Trak Transit Time

PhD Inline Vortex. Performance Specifications Accuracy. Operating Specifications

OPTIFLUX 5000 Technical Datasheet

Digital conductivity transmitter

The transducer component converts the measured signal and displays the actual value.

Dissolved Oxygen Transmitter

Electromagnetic Flow Transmitter

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector

Digital inductive conductivity transmitter

Magnetic Flowmeter Systems

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

MagneW Two-wire PLUS+ Two-wire Electromagnetic Flowmeter

Design and applications

General Specifications

ABB Instrumentation. Flowmeter. Specification DataFile

Mobrey Ultrasonic. MSP422, MSP400RH, and MSP900GH Level Transmitters. Product Data Sheet February 2015 IP2045, Rev EA

KFS. Flap-type flow meter. Design and range of application

RCM DIRECT READING FLOWMETER

Smart Electromagnetic Flowmeter Open channel Flowmeter Detector

GS.No.GBN062E-5. GENERAL SPECIFICATIONS Sensor unit

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9

} Max. Load Resistance : 750Ω when power supply voltage is 24V DC (Max. load resistance (Ω) = 50x Power Supply Voltage -450 ).

FLOMID FX Electromagnetic Flowmeter

RHE12. Hazardous Area Coriolis Mass Flow Transmitter. Features. Applications. Benefits

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

TEK-TEMP 2100A. Explosion-Proof Temperature Transmitter. TEMPERATURE. Technology Solutions

WATERFLUX 3070 Technical Datasheet

KMS101W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S100 display

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI

PAD - Heavy Duty Differential Pressure Trasmitter

WATERFLUX 3000 Quick Start

Advanced instrumentation solutions crafted with highest precision

Series 10-ZSE30A(F)/10-ISE30A

TOSHIBA INTERNATIONAL CORPORATION. Magmeter Quick Start Guide

Technical Information Proline Promag 10P

INLINE flowmeter for continuous flow measurement

Mass and Volume Flow Transmitter

Magnetic-Inductive flow Meter fmi

Level Lance Model 5100

EN-2018 MAGNETIC FLOW METERS

KFS-EM. Overall length. Al. PTFE coated Alu, painted Al. coated Methacrylate / acrylic nitrite

JUMO flowtrans MAG S01

Abridged Specifications: 10DS3111E/A Sensor with 50SM1000 Transmitter

Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 P

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM

KMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm)

Cable transducer Analog output / redundant Measuring length absolute up to 5 m

STT 3000 Smart Temperature Transmitter

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

General Specifications

Electromagnetic flowmeters and switches DWM 1000/2000

Digital flow ELEMENT transmitter for continuous flow measurement

INLINE flowmeter for continuous flow measurement

Technical Information Smartec CLD18

SITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI

INSERTION paddle wheel flowmeter for continuous flow measurement

Digital flow transmitter for continuous flow measurement

U5300 Industrial Pressure Transducer

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

Efcon Water. Installation & User Manual Electro Magnetic Flowmeter (EMF) Efcon Water compact Electro Magnetic Flowmeter (EMF) Manual Version UK

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:

Digital flow ELEMENT transmitter for continuous flow measurement

Conductivity measurement SmarTec S CLD 132

Technical Information Smartec CLD18

General Specifications

USER MANUAL MODEL USFT-CS ULTRASONIC FLOW TRANSMITTER. Rev04009 USER MANUAL DEI MODEL USFT-CS

MHPS MHPS. Modular pressure transmitter. Technical documentation. Table of content. Characteristics - applications - technical data

Electromagnetic Flow Measuring System promag 35

Conductivity Transmitter

High Performance Coriolis Flowmeters

KENCO Loop Powered Magnetostrictive Transmitter. KMD SERIES Operation and Installation Manual. Table of Contents

Metal tube variable area flowmeters for gases, liquids and steam

Smart Displacer Level (Interface) Transmitter DLT100 Series

Level Measurement Continuous level measurement Radar transmitters

LST400 Ultrasonic level / open channel flow transmitter

OPTISONIC 7300 Technical Datasheet

Transcription:

Field Intelligent Device Series Electromagnetic Flowmeter LF450 /LF610 LF450 /LF612 20" to 24" (500 to 600 mm) Introduction The electromagnetic flowmeter uses Faraday s Law of electromagnetic induction to measure the process flow. The device consists of two units: a detector, through which the fluid to be measured flows and in which low-level signals proportional to flow rates are obtained; and a converter, which supplies excitation current to the detector, and amplifies the signals from the detector and then processes and converts the signals into the 4 20mAdc current signal or communication signal. With the unique patented Mount-Anywhere magnetic field distribution technology, the meter is highly immune to upstream flow disturbances. Combined with a multi-functional converter LF610 (combined type) or LF612 (separate type) equipped with its patented Noise-Sentry original noise-suppression circuit and advanced algorithms. The LF450 has a very high tolerance to noise, giving the unit a very stable output even for slurry fluid measurement. IR (Infrared) switches enable parameter setting of the converter without removing the cover. Flow direction can be set in either way, and its unique 128 x 128 dot matrix LCD display allows the LCD to be rotated electronically to 90, 180 and 270 degrees without opening the cover. The LF450 detector can also be used with a separate type converter LF232 which provides high performance such as Digital Inputs (two points) along with Digital Outputs (four points), and multi-functions. The AF900 hand-held terminal (HART* 1 communicator) can be used to communicate with the flowmeter from a remote place. PROFIBUS-PA* 2 interface is available as an option. *1: HART protocol (Highway Addressable Remote Transducer) is a communication protocol for industrial sensors recommended by the HCF (HART Communication Foundation). *2: PROFIBUS is the communications protocol for factory and process automation that the PROFIBUS Organization recommends. Instead of analog control with a conventional analog signal (4-20mA), it is fieldbus which digitizes all signals. Flowmeters support PROFIBUS-PA. I/O Power supply Detector Converter Combined type LF450/LF610 Power supply I/O Excitation cable Detector Separate type LF450/LF612 Figure 1. Configuration Converter Signal cable Terminal box Figure 2. Electromagnetic Flowmeter LF450 Specifications Certification number Z01207 Overall Specifications Measurement range in terms of flow velocity: 0 1.0 ft/s to 0 32.8ft/s. (0 0.3 m/s to 0 10 m/s). Accuracy ± 0.3% of Rate * * This output error result is established under standard operating conditions at Toshiba s flow calibration facility, Fuchu Japna. * Individual meter measurement error may vary up to ±0.5 % of Rate at 3.28 ft/s (1.0 m/s) or more and ± 0.3% of Rate ±0.079 inch/s (2 mm/s) at 3.28 ft/s (1.0 m/s) or less. * Current output: plus ± 8µA (0.05% of span.) * Refer to individual calibration data for each individual meter s measurement error. Fluid conductivity: 5µS/cm minimum Fluid temperature: 14 to 140 F ( 10 to +60 C) Ambient temperature: 14 to 140 F ( 10 to +60 C) Structure: Standard IP67 and NEMA 4X Watertight Option IP68 and NEMA 6P Submersible type The coating for this type is black tar epoxy resin coating 0.5 mm. This type of flowmeter is submersible to 5 m in water.

Power consumption: 17W(27VA) or less 19W(29VA) or less (with PROFIBUS) Model LF450 Detector Mounting style: Flanged connection type Fluid pressure: -15 to 300 psi, or -1.0 to 20 bar (-0.1 to 2.0 MPa) (Depending on each flange standard) Note: The test pressure before shipping from the factory is equal to twice the nominal pressure rating of the customer specified flange connection during 15 minutes. Connection flange standards: ANSI class 150, BS10 BS 16, DIN PN10, DIN PN16, JIS10K Principal materials: Case carbon steel Linings Chloroprene rubber (std.) or EPDM rubber Electrodes Type - Super smooth, polished with self cleaning finish, and non stick shape. 316L stainless steel (std.) Grounding rings None (std.) Note: See Table 5 for optional materials and other related information. Measuring tube material 304 stainless steel Coating Corrosion resistant phthalic acid resin coating (std.), pearl-gray colored Note: If the optional IP68 and NEMA 6P Submersible type is specified, the coating is black tar epoxy resin coating 0.5 mm. Dimensions and weight: See Figures 3 and 4. Cable connection port: for separate type detectors. Cable gland LF450: Provided as standard, R(PT) 1/2 male screws. Mount-Anywhere Technology: With TOSHIBA s unique patented magnetic field distribution technology, the meter is highly immune to upstream flow disturbances. A minimum of 1D (one diameter) length of upstream straight pipe from the flange is required to maintain the performance specification. Note : The test results were obtained and demonstrated at TOSHIBA's flow calibration facility, Fuchu Japan. Model LF610 and LF612 converters Input signals Analog signal the voltage signal from detector, proportional to process flow rate (for LF612 separate type converter). Digital input DI (opt.) Signal type: 20 to 30Vdc voltage signal Input resistance: 2.7kΩ Number of inputs: one point DI function One of the following functions can be assigned to the optional DI signal. Range switching Selects either the higher or lower range in the unidirectional or bidirectional 2-range setting. Totalizer control Starts and stops the built-in totalizer. Fixed-value outputs Outputs fixed-values for current and pulse outputs. Zero adjustment Executes zero adjustment (on-stream at zero flow rate). Output signals Current output: 4 20mAdc (load resistance 0 to 750Ω) Note: The current output cannot be used with the PROFIBUS-PA communication. Digital outputs One point (std.) and one more point is optionally available as follows. Digital output DO1 (std.): Output type: Transistor open collector Number of outputs: One point Output capacity: 30Vdc, 200mA maximum Digital output DO2 (opt.): Output type: Solid-state relay output (non polarity) Number of outputs: One point Output capacity: 150Vdc, 150mA maximum or 150Vac (peak to peak), 100mA maximum DO1 and DO2 functions One of the following functions can be assigned to DO1 (std.) and/or DO2 (opt.) Pulse output (available only for DO1, DO2) Pulse rate: 3.6 to 36,000,000 pulses/hr (DO1) 3.6 to 360,000 pulses/hr (DO2) (Over 3,600,000 pulses/hr, auto-setting) Pulse width: 0.5 to 500ms (but less than half of the period for 100% flow rate) Note: The same and simultaneous pulse is not available between DO1 and DO2.) Multi-range selection outputs (Note 1) High, High high, Low, and/or Low low alarm outputs (Note 2) Empty pipe alarm output

Digital Output Active Status (DO1 and DO2) (Note 2) Preset count output Converter failure alarm output Note 1: Two outputs (DO1 and DO2) are needed for 4-range switching and forward/reverse 2-range switching. Note 2:Normal Open (default set) or Normal Close is selected for alarm outputs when programming. When power failure occurs, unit will be fault to Normal Open. Communications output: HART (std.) Digital signal is superimposed on 4 20mAdc current signal as follows: Conforms to HART protocol Load resistance: 240 to 750Ω Load capacitance: 0.25µF maximum Load inductance: 4mH maximum PROFIBUS(opt.) Protocol: PROFIBUS-PA Baud rate: 31.25kbps Bus voltage: 9-30VDC Consumption electric current of bus: less than 16mA Manufacture Ident-No.: 093B HEX Standard Ident-No.: 9740 HEX Slave address: 0-126 (Default address is 126) Profile: Profile Ver.3.01 for Process Control Devices Function blocks: AI(Flow) 1, Totalizer 1 LCD display: Full dot-matrix 128 128 dot LCD display (back light provided) The data on the LCD inside the converter can rotate to 90, 180, and 270 degrees by a software, without rotating the indicator itself. (Combined type only) Parameter settings Parameters can be set as follows: IR Switches: Three key switches are provided to set configuration parameters. Digital communication: The AF900 hand-held terminal or PROFIBUS is needed to set parameters. Zero adjustment: Zero point adjustment can be started by pressing the switch in the converter. Damping: 0.5 to 60 seconds (selectable in one second increments) Field re-verification Mag-Prover Toshiba s Zero span calibration tool allows unit to be re-calibrated and verified using an internal software program. (For more information contact Toshiba International Corp.) TIC-LF450B Conditions when power fails: Parameter setting values are stored in non volatile memory and the values will be restored when the power returns to normal condition. The outputs and display will remain as follows when power fails. Current output: 0mAdc Digital output: OFF LCD display: No display PROFIBUS: No communication Power supply: One of the following can be selected: 100 to 240Vac, 50/60Hz (std.) (allowable voltage 80 to 264Vac) 24Vdc (allowable voltage 18 to 36Vdc) 110Vdc (allowable voltage 90 to 130Vdc) Surge protection: Arresters are installed in the power supply and a current signal output circuit to help protect the meter from lightning and improve personnel safety. Case: Aluminum alloy (equal to IP 67) Coating: Acrylic resin-baked coating, pearl gray colored Cable connection port: Cable glands LF610 and LF612 without cfmus Approval: Provided as standard, OD of cable 11~13mm Material Nylon 66 G (PF) 1/2 male screws. LF610F and LF612F with cfmus Approval: Not provided, 1/2 14NPT male screws are required. Applicable diameter 0.433 to 0.512 inch (11 to 13mm) Note: When PROFIBUS option is specified, cable gland size is φ6 ~8mm for signal cable, φ11~13mm for power cable Vibration resistance: No resonance to the following levels of vibration: 10 to 150Hz with acceleration of 9.8m/s 2 Vibration of 30Hz with 29.4 m/s 2 in 4h in each direction will not cause any defect to unit. Note: Avoid using the flowmeter in an environment with constant vibration. Dimensions and s: See Figure 5 (for Separate type) MTBF: Converter: 220,000 hours (25 years) at 77 F (25 C) based on strict military specification MIL-HDBK-217F Detector: 350,000 hours (40 years) at 77 F (25 C) based on strict military specification MIL-HDBK-217F 3

Installation Dimensions See the following tables for dimensions, L2 and indicated in Figure 3. Unit:inch( mm) Bolt holes 8.86(225) 5.16(131) 1.42(36) 5.63(143) ANSI class 150 dimensions: L2 (lb) 20 23.35 18.72 32.48 20 approx. 470 24 23.35 20.77 36.77 20 approx. 620 L2 BS16 and DIN PN16 dimensions: L2 (kg) 500 600 476 833 20 approx. 180 600 600 528 947 24 approx. 240 JIS 10K dimensions: L2 (kg) 500 600 476 813 20 approx. 180 600 600 528 925 24 approx. 240 Note: 1 inch = 25.4 mm Figure 3. LF450/LF610 Combined type s 20 (500mm) and 24 (600 mm) Unit:inch See the tables below for dimensions, L2 and indicated in Figure 4. Bolt holes 3.46(88) 1.57(40) 4.96(126) 1.38(35) 3.58(91) ANSI class 150 dimensions: (L2) (lb) 20 23.35 15.81 29.57 20 approx. 470 24 23.35 17.90 33.90 20 approx. 620 L2 BS16 and DIN PN16 dimensions: (L2) (kg) 500 600 403 760 20 approx. 180 600 600 455 874 24 approx. 240 JIS 10K dimensions: (L2) (kg) 500 600 403 740 20 approx. 180 600 600 455 852 24 approx. 240 Note: 1 inch = 25.4 mm Figure 4. LF450 Separate type detector s 20 (500mm) and 24 (600 mm

5.94(151) 2.91(74) ±0.3 4 4-φ11 φ0.43(φ11) Attachment 取付金具 LCD 表示器 display 0.98(25) 3.23(82) 0.51(13) 13 Excitation 励磁ケーブルグランド cable ground Unit:inch I/O 電流出力ケーブルグランド cable ground 5.94(151) 7.01(178) 178 7.87(200) 1.42(36) 6.41(156) 156 接地端子 Ground terminal (M4) (M4) 取付金具 Signa 信号ケーブル l cable ground Power supply cable ground 電源ケーブルグランドグランド Blind 封止栓 screw 矢視 A 赤外線スイッチ IR Switch Cable ケーブルグランド ground 矢視 A Note : 1 inch = 25.4mm ( 単位 :mm) External Connections Combined type LF450/LF610 flowmeters Ground terminal Intermediate voltage (IV) wire, 5.5mm 2 or more. To be grounded with 100Ω or less ground resistance. Figure 5. Separate type converter LF612 I/O Cable (CVV-S) Instrument Panel : Ordered separately Current output (4~20mAdc) or PROFIBUS Digital Output 1 Signal common for DI and DO Digital Output 2 Digital Input (20 to 30Vdc) Grounded with 100Ω or less ground resistance Grounded with 100Ω or less ground resistance Power supply Power Cable (CVV) Power Switch *1 (External double-pole power switch) *1 Locate an external double-pole power switch on the power line near the flowmeter within easy reach of operation. Use the appropriate switch rating as shown below: Switch rating: 250Vac, 6A or more In rush current: 15A or more Figure 6. Combined type LF450/LF610 flowmeters Wiring Diagram 5

Separate type LF450/LF612 flowmeter Terminal board Thick walled steel conduit Signal cable (2-wire shielded hard-rubber sheathed cable) Connected detector Excitation cable (3-wire shielded hard-rubber cable) Power cable (CVV) Digital input cable (CVV-S) IV wire 5.5 mm 2 or more Grounded with 100Ω or less ground resistance * 1 Power switch (External double-pole power switch ) [Instrument panel : ordered separately] Grounded with 100Ω or less ground resistance Power supply Current output (4~20mAdc) or PROFIBUS Digital output 1 Signal common for DI and DO Digital output 2 Digital input (20~30Vdc) Grounded with 100Ω or less ground resistance Figure 7. Separate type LF450/LF612 flowmeters wiring Diagram Table 1. LF610, LF612 Converter Signal Table Symbol Description Cable (+) L2 (-) Power supply Power cable (CVV) GND Ground (for arrester) FG Frame ground DI Digital Input (20~30Vdc) DO1 Digital Output 1 DO2 Digital Output 2 COM Signal Common for DI, DO1, DO2 I/O cable (CVV-S) + - Current Output (4~20mAdc) or PROFIBUS Shielded cable for PROFIBUS-PA X Y E A B G Excitation Output Signal Input Excitation cable (for LF612 only) Signal cable (for LF612 only)

Wiring Precautions (1) Connect the grounding wire (IV wire 5.5mm² or more) to a good earth ground (100Ω or less ground resistance). Make the wire as short as possible. Do not use a common ground shared with other equipment where earth current may flow. An independent earth ground is recommended. (2) The allowable cable lengths between the detector and converter for the separate type flowmeter depend on the electrical conductivity of the object fluid. See Figure 8. (3) DO1, DO2 (opt.), and DI (opt.) use the same common terminal (COM). This COM can not connect to other equipments which have their own ground terminal. (Power supply for connecting to DI or DO, etc ) Need to wire separately. (4) DO1, DO2 (opt.), and DI (opt.) use the same common terminal (COM). This COM can not connect to other equipments which have their own ground terminal. (Power supply for connecting to DI or DO, etc ) Need to wire separately. Wiring Precautions (PROFIBUS) (1) For wiring path, avoid places near electrical equipment that may cause electromagnetic induction or electrostatic induction interference (such as a motor, transformer and wireless transmitter). (2) Use a PROFIBUS-PA cable for signal cable. In addition, make sure to use a shielded cable to improve noise resistance. Furthermore, installation of signal cable in metal conduit is recommended. (3) General PROFIBUS-PA cables are designed for indoor use where cables are not exposed to humidity, rain, etc. When you install cables, make sure to check the operating conditions such as the operating temperature range of the cable by contacting its manufacturer. (4)When you carry out cable end treatment of PROFIBUS-PA cable, use a dedicated cable stripper etc. so that the core wire of the cable will not be nicked or damaged. In addition, for cables, be careful of allowable maximum bend diameter etc. (Basically, do not install cables in a way cables are twisted or bent.). (5)Consider installing a PROFIBUS-PA arrester in the communication path of PROFBUS-PA so that the electromagnetic flowmeter will not be affected by lightning etc. (6) The electromagnetic flowmeter is not equipped with terminating resistors. Use the terminating resistor unit for PROFIBUS-PA or junction box, if necessary. (7) Only one PROFIBUS-PA cable goes through a cable gland of the Electromagnetic Flowmeter. Please use the junction box at system configuration. Allowable cable length (m) 300 200 100 50 30 20 10 5 3 3 5 10 20 30 50100200 Conductivity (µs/cm) Figure 8. Electrical Conductivity and Cable Length TIC-LF450B To select the meter size: See the Table 2 to 3 and find meter sizes within the velocity of 0.98 to 32.8 ft/s (0.3 to 10 m/s) to for a specified full-scale (measuring range high limit) flow rate. Select one that has its full-scale velocity between 3.0 and 10 ft/s (1 and 3 m/s). Note: Make sure the full-scale flow rate used for the final planning stage stays within 32.8ft/s (10 m/s) in terms of flow velocity. Table 2. Flow Rate and Flow Velocity (English unit) Unit :gal/min Flow rate 0.98ft/s 3ft/s 10ft/s 32.8ft/s 20 933.7 2,846 9,486 31,120 24 1,344 4,098 13,660 44,820 Table 3. Flow Rate and Flow Velocity (SI unit) Unit : m 3 /h Flow rate 0.3 m/s 1.0 m/s 3 m/s 10 m/s 500 212.1 706.9 2,121 7,069 600 305.4 1,018 3,054 10,180 7

Calibration Range If the calibration range is not specified, the standard range as shown below will be used. If the range is specified, we will use the specified range for calibration. Table 4. Standard Flow Range Standard flow range inch Flow rate Flow rate Flow velocity (gal/min) (m³/h) (m/s) 20 (500) 25,000 3,000 4.244 24 (600) 40,000 4,000 3.930 Piping materials (to be ordered separately) Mating flanges: The flowmeter must be mounted with its detector pipe connected between the flanges in the pipeline. If no flanges are used where the flowmeter is to be mounted, mating flanges are required. Adjustable short pipe: When both the upstream and downstream pipe sections cannot be adjusted laterally along the pipeline, an adjustable short pipe may be required. Reducers: When the flowmeter with its smaller than that of the pipeline should be installed, reducers are required on both ends of the flowmeter detector. Reducers with pipe extensions: Reducers with adjustable piping mechanism. About establishment environment Do not store or install the flowmeter: Where there is direct sunlight. Where excessive vibration or mechanical shock occurs. Where high temperature or high humidity conditions exist. Where corrosive atmospheres exist. Places that can be submerged under water. Where there is a slopede floor. To put the flowmeter temporarily on the floor, place it carefully with something, such as a block, to support it so that the flowmeter will not topple over. In areas like the following, there may be the case that infrared switches do not function correctly. (If these are unavoidable, use an appropriate cover.) (1) Where unit (operation panel) is exposed to direct sunlight, reflection of light onto window pane and diffused light reflection. (2) Where smoke and steam may occur. (3) Where exposed to direct snow, ice or mud. Ordering Information 1. When ordering the LF450 series flowmeters, refer to Tables 5 and 6 (Type Specification Codes). An entry must be made for each of the columns in each of these tables. 2. Fluid characteristics: (1) Type of fluid to be measured and its characteristics (2) Fluid temperature (3) Fluid pressure (4) Electrical conductivity of the fluid 3. Measuring range 4. I/O function setting 5. Ordering scope: Flow calibration data: (required or not) 6. Other items Specifications other than standard items Consult a Toshiba representative before ordering when choosing materials of the wetted parts such as lining, electrodes, and grounding rings. 8

Model Table 5. Specification Code (Flange type detector LF450 Series) Specification Code 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Code explanation: : Standard : Option Note: 1. Separate type detector only. 2. Separate type detector only. Specify length of cable from 1 to 300 m in 1 meter increments.. Description L F 4 5 0 LF450 Flowmeter 5 20"(500mm) 6 24"(600mm) Mounting style L Detector / Converter combined type M Detector / Converter separate type Connection flange standard C ANSI 150 E BS 10 F BS 16 G DIN PN 10 H DIN PN 16 J JIS 10K Electrode Material B 316L stainless steel C Ti (titanium) Lining Material D EPDM rubber E Chloroprene rubber Grounding Ring Material / Roll prevention Base A Both are not provided J 304 stainless steel / Base not provided K 316 stainless steel / Base not provided L 304 stainless steel / Base provided M 316 stainless steel / Base provided N Ring not provided / Base provided Calibration range A Standard range calibration B Specification range calibration Dedicated Preformed Cable A Not provided B 30m cable, provided (Note 1) C Other lengths, provided (Note 2) Coating B Phthalic zcid resin C Black tar epoxy resin 0.3mm D Black tar epoxy resin 0.5mm E Black tar epoxy resin 0.5mm (for submersible type) Use 9

Table 6. Specification Code for converters Model Specification Code Contents LF610 LF612 1 2 3 4 5 6 7 8 9 10 11 12 13 14 type type L F 6 1 Electromagnetic flowmeter converter 0 Combined (Integral) type 2 Separate (Remote) type Purpose A Standard Shape A B Integral type with case Separate type with case A C E 1 2 1 2 1 2 3 Converter mounting fitting None Panel, Accessory for wall mounting (BNP material: SUS304) Accessory for pipe installation (BNP material: SUS304) Digital input/output Digital output points 1 (DO1) Digital output points 2 (DO1+DO2) +Digital input point 1 (DI) Current output and Communication function Current output + HART communication PROFIBUS communication (Current output is not usable) Power supply 100Vac-240Vac, 50/60Hz 24Vdc 110Vdc Instruction manual E English Code explanation: : Standard : Option : Not available 10