Secondary Electron Detector

Similar documents
SECONDARY ELECTRON DETECTION

(Refer Slide Time: 00:10)

Scanning Electron Microscopy SEM. Warren Straszheim, PhD MARL, 23 Town Engineering

MODULE I SCANNING ELECTRON MICROSCOPE (SEM)

SCANNING ELECTRON MICROSCOPY AND X-RAY MICROANALYSIS

5. The Scanning Electron Microscope

Functions of the SEM subsystems

OPERATION OF THE HITACHI S-450 SCANNING ELECTRON MICROSCOPE. by Doug Bray Department of Biological Sciences University of Lethbridge

PROCEEDINGS OF A SYMPOSIUM HELD AT THE CAVENDISH LABORATORY, CAMBRIDGE, Edited by

ZEISS EVO SOP. May 2017 ELECTRON OPTICS

SOP for Hitachi S-2150 Scanning Electron Microscope For review purposes only

Scanning electron microscope

Scanning Electron Microscopy

Scintillation Counters

Observing Microorganisms through a Microscope LIGHT MICROSCOPY: This type of microscope uses visible light to observe specimens. Compound Light Micros

CHAPTER 11 HPD (Hybrid Photo-Detector)

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

Scanning Electron Microscopy. EMSE-515 F. Ernst

Standard Operating Procedure for the Amray 1810 Scanning Electron Microscope Version: 29 NOVEMBER 2014

Scanning electron microscope

Design and Application of a Quadrupole Detector for Low-Voltage Scanning Electron Mcroscopy

Chapter 1. Basic Electron Optics (Lecture 2)

Topics 3b,c Electron Microscopy

Photomultiplier Tube

The Contrast-to-Noise Ratio for Image Quality Evaluation in Scanning Electron Microscopy

MCR Scanning Electron Microscopy Laboratory Portfolio

Atomic and Nuclear Physics

Introduction to Scanning Electron Microscopy

Density vs. Contrast

Introduction: Why electrons?

PMT Calibration in the XENON 1T Demonstrator. Abstract

Module 4B7: VLSI Design, Technology, and CAD. Scanning Electron Microscopical Examination of CMOS Integrated Circuit

Gamma Ray Spectroscopy with NaI(Tl) and HPGe Detectors

VISUAL PHYSICS ONLINE DEPTH STUDY: ELECTRON MICROSCOPES

Homework Set 3.5 Sensitive optoelectronic detectors: seeing single photons

S200 Course LECTURE 1 TEM

Using the Hitachi 3400-N VP-SEM

Scanning Electron Microscopy Basics and Applications

JSM 6060 LV SCANNING ELECTRON MICROSCOPE STANDARD OPERATING PROCEDURES

Image formation (Slides 1-104)

Marine Invertebrate Zoology Microscope Introduction

Choosing the Right Accelerating Voltage for SEM (An Introduction for Beginners)

Explain what is meant by a photon and state one of its main properties [2]

SCANNING ELECTRON MICROSCOPY By W. C. NIXON (Engineering Laboratory, Cambridge University)

Leica TCS SP8 Quick Start Guide

Chemistry Instrumental Analysis Lecture 7. Chem 4631

ELECTRON MICROSCOPY AN OVERVIEW

Low Voltage Electron Microscope

Scanning Electron Microscope in Our Facility

Detectors for Sensitive Detection: HyD

Photons and solid state detection

Lecture 20: Optical Tools for MEMS Imaging

Confocal Microscopy. Kristin Jensen

NM Module Section 2 6 th Edition Christian, Ch. 3

Positron Emission Tomography

LOW VOLTAGE BACKSCATTERED ELECTRON IMAGING (< 5 KV) USING FIELD EMISSION SCANNING ELECTRON MICROSCOPY

A NEW TECHNIQUE TO RAPIDLY IDENTIFY LOW LEVEL GATE OXIDE LEAKAGE IN FIELD EFFECT SEMICONDUCTORS USING A SCANNING ELECTRON MICROSCOPE.

Scanning Electron Microscope FEI INSPECT F50. Step by step operation manual

General information. If you see the instrument turned off, notify MIC personnel. MIC personnel will help you insert your samples into the instrument.

V SALAI SELVAM, AP & HOD, ECE, Sriram Engg. College, Perumalpattu 1 MEDICAL ELECTRONICS UNIT IV

DETECTORS Important characteristics: 1) Wavelength response 2) Quantum response how light is detected 3) Sensitivity 4) Frequency of response

Operation Guide. Hitachi S-3400N. Variable Pressure Scanning Electron Microscope. with. Deben Peltier Coolstage

OPTI510R: Photonics. Khanh Kieu College of Optical Sciences, University of Arizona Meinel building R.626

NANO 703-Notes. Chapter 9-The Instrument

Dickinson College Department of Geology

Electron

RADIOGRAPHIC EXPOSURE

JEOL 6500 User Manual

The light microscope

Scanning Electron Microscopy Laboratory Portfolio

Ph 3324 The Scintillation Detector and Gamma Ray Spectroscopy

The Light Amplifier Concept

Light Collection. Plastic light guides

How to choose a Scanning Electron Microscope (SEM)

Low Voltage Electron Microscope. Nanoscale from your benchtop LVEM5. Delong America

Model SU3500 Scanning Electron Microscope

ELECTRON MICROSCOPY. 14:10 17:00, Apr. 3, 2007 Department of Physics, National Taiwan University. Tung Hsu

Transmission Electron Microscopy 9. The Instrument. Outline

80 Physics Essentials Workbook Stage 2 Physics

X-ray generation by femtosecond laser pulses and its application to soft X-ray imaging microscope

University of Washington Molecular Analysis Facility

Ground-based optical auroral measurements

Confocal and 2-photon Imaging. October 15, 2010

PAD Correlator Computer

PRACTICAL CONSIDERATIONS AND EFFECTS OF METALLIC SCREEN FLUORESCENCE AND BACKSCATTER CONTROL IN GAMMA COMPUTED RADIOGRAPHY

Radionuclide Imaging MII 3073 RADIONUCLIDE IMAGING SYSTEM

Lecture 12 OPTICAL DETECTORS

Scanning Electron Microscopy Student Image Portfolio

Oct. 30th- Nov. 1st, 2017

Page 1. Ground-based optical auroral measurements. Background. CCD All-sky Camera with filterwheel. Image intensifier

!"#$$%$&'()*"+,-$'.%",-/"-0*'-$'#'12%0'

Chapter 4 Imaging Lecture 17


Oct. 30th- Nov. 1st, 2017

Operating Checklist for using the Scanning Electron. Microscope, JEOL JSM 6400.

Introduction to Image Intensifier Tubes

PH2510 Nuclear Physics Laboratory Use of Scintillation Counters (NP5)

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

Meshing Challenges in Simulating the Induced Currents in Vacuum Phototriode

Scanning Electron Microscope. Instructions for Use

Transcription:

Secondary Electron Detector Fig. 17 Everhart-Thornley Detector (Fig. 7-9, p. 215, Bozzola and Russell) Secondary electrons (SE) are attracted to Faraday cage because of its positive charge. Detector surface inside faraday cage (+12kV) accelerates electrons. Scintillator layer gives off photons when struck by electrons Light travels down the light tube (LG) and hits photocathode and converted back to electrons 11

Fig. 18 Photomultiplier Tube (Fig. 7-11, p. 216, Bozzola & Russell) Electrons from the photocathode pass through a series of dynodes in the photomultiplier which progressively increase their number. (total increase can be as high as 10 6 ). This amplification or gain, is controlled by the contrast control on the SEM. An increase in contrast is seen as a selective increase in the highlights of the image, rather then the shadows. The brightness of the image is controlled by the preamplifier or brightness control. In this case, both highlights and shadow areas of the image are amplified by the same amount. Signal to Noise Ratio is a measure of the quality of the image decreases as the gain control is increased noise originates from backscattered electrons and electrical static in circuitry 12

Signal Processing and Gamma No gamma Gamma of 2.0 Fig. 19 Image Gamma (Fig. 7-12, p. 217, Bozzola & Russell) measure of the contrast range of an image the gamma control on the SEM enables contrast in the highlight or shadow regions of the image to be extended without affecting the mid-range gray levels of the image. On the S-500, the 0 setting means gamma is off, and 1, 2, and 3 progressively decrease peaks and troughs of the waveform to enhance shadow and highlight contrast range. The waveform in the diagram to the left shows extremes of bright and dark peaks in the image which will not be captured on the negative. The ideal image is usually produced by restricting the waveform so that the peaks and troughs lie within the two black lines that are taped onto the left computer screen in the S-500. The waveform is modified by the brightness and contrast controls, and if necessary, the gamma control. Brightness = height of the waveform Contrast = peak-to-trough distance Fig. 20 Waveform on Left crt of S-500 SEM Both brightness and contrast are affected by tilt, accelerating voltage, condenser lens current and aperture diameter. 13

Factors Affecting Secondary Electron Image Fig. 21 Specimen Topography (Fig. 7-16, p. 219, Bozzola & Russell) Specimen Topography In the diagram above, as the beam scans from left to right, areas marked B will be bright because they are scanned by the beam and in the line of sight of the detector. Areas marked I are intermediate in brightness because they are out of the line of sight of the detector. Regions D will be dark because they are not scanned with the beam at all. Tilting the specimen will alter the specimen topography relative to the beam and detector and may enhance or reduce image quality. Beam angle relative to surface topography The edges of objects are often brighter than their centers due to interaction of the beam with the specimen surface. More secondary electrons escape from the edges because the zone of interaction is closer to the surface as the diagram below illustrates: Fig 22 Zone of Interaction (Fig. 7-17, p. 220, Bozzola & Russell) 14

Surface projections and the edges of depressions in the specimen surface also generate more secondary electrons than flat surfaces, thus giving them a brighter appearance than flat surfaces. This effect is also due to zone of interaction between beam and specimen. Fig. 23 Edge Effect (Fig. 7-18, p. 220, Bozzola & Russell) Accelerating Voltage As accelerating voltage increases, the beam penetrates deeper into specimen, i.e. the zone of interaction gets deeper. As beam penetrates deeper into the specimen, less secondary electrons can escape. Secondary electrons can only escape from a limited depth (E) below the surface. E Low kv Med kv High kv Fig. 24 Effect of Accelerating Voltage on Secondary Electron Emission For most biological specimens, 5-15 kv gives best combination of resolution and S/N ratio. For dense biological specimens (i.e. diatoms, teeth, bones) 20-30 kv may give better results because the zone of penetration is reduced and the yield of secondary electrons is theoretically increased. Atomic Number As atomic number increases, the yield of secondary and backscattered electrons increases and the image increases in brightness. 15

Image Charging Due to an inability of the specimen to ground absorbed electrons. Results in extreme brightness of some regions, i.e. hairs, adhering dust, etc. Can be minimized by reducing the number of primary beam electrons striking the specimen, by: a) reducing accelerating voltage b) increasing condenser lens current c) reducing aperture diameter d) increasing gamma e) recoating specimen (increases charge dissipation) 16