R&S ENV216 Two-Line V-Network For disturbance voltage measurements on single-phase EUTs

Similar documents
R&S ZV-Z5x Calibration Units Specifications

R&S ZV-Z5x Calibration Units Specifications

R&S ZVT Vector Network Analyzer Specifications

R&S RSC Step Attenuator Specifications

ENY81 Coupling Network

R&S ZV-Z3xx T-Checker Specifications

R&S FU129 Antenna Filter Unit Antenna switching, rotator control and signal attenuation, amplification and filtering

R&S ZV-Z135 Calibration Kit Specifications

MDS-21 Absorbing Clamp, EZ-24 Ferrite Clamp

R&S ZNC Vector Network Analyzer Specifications

Vector Network Analyzers ZVB

R&S ZNB Vector Network Analyzer Specifications

R&S CMU-Z10/-Z11 Antenna Coupler/ RF Shielding Cover Simple interference-free testing of all mobiles

R&S ZVT Vector Network Analyzer Specifications

R&S ZN-Z5x Calibration Units Specifications. Data Sheet V03.00

R&S ZN-Zxxx Calibration Units Specifications. Data Sheet V04.00

Attenuators and Matching Pads, Terminations 75 mw to 1000 W, DC to 18 GHz

R&S SMZ Frequency Multiplier Precise andadjustable output levels from 50 GHz to 110 GHz

R&S CBT/R&S CBT32 Bluetooth Tester Specifications

R&S FSH4/8 Spectrum Analyzer Specifications

R&S ESCI/ESCI7 EMI Test Receiver Specifications

Power Added Efficiency Measurement with R&S ZNB/ R&S ZVA

R&S ZNBT8 Vector Network Analyzer Specifications

R&S FSC Spectrum Analyzer Specifications

R&S EB500 Monitoring Receiver Specifications

R&S SMC100A Signal Generator Specifications

Complimentary Reference Material

R&S ZVA-Zxx Millimeter-Wave Converters Network analysis up to 500 GHz

Noise Figure Measurement in the 60 GHz Range Application Note

LabWindows/CVI, VXIpnp driver history for the R&S Radio Tester

R&S FSV Signal and Spectrum Analyzer Specifications

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

Noise Figure Measurement Applications Specifications

Keysight Technologies 87405C 100 MHz to 18 GHz Preamplifier. Technical Overview

R&S FSV Signal Analyzer Specifications

Voltage Sensors URV5-Z

Two Line V-Network GLN-5040A USER MANUAL GW INSTEK PART NO. 99 Washington Street Melrose, MA Phone Toll Free

HF Transmit/Receive Broadband System XB 2900

Spectrum Analyzer FSL

R&S NRPM Over-the-Air (OTA) Power Measurement Solution For 5G, WLAN IEEE ad and IEEE ay

Keysight Technologies 8490G Coaxial Attenuators. Technical Overview

PRODUCT DATA. Sound Intensity Calibrator Type 4297

Keysight Technologies P9400A/C Solid State PIN Diode Transfer Switches

R&S FS-K112PC NFC Measurement Software Specifications

12.5 Gb/s Driver Amplifier LABware Module PSPL8001 Datasheet

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Programmable Pulse Generators PSPL10050A, PSPL10060A, PSPL10070A Datasheet

30 A AC/DC Current Probe TCP0030A Datasheet

R&S TS-PSAM Analog Source and Measurement Module Scanning multimeter and data acquisition unit

R&S ESRP EMI Test Receiver Specifications

Keysight N9310A RF Signal Generator

Keysight Technologies Waveguide Power Sensors. Data Sheet

Keysight 8762F Coaxial Switch 75 ohm

io n Data Sheet or The P5205 is a 100 MHz Active Differential Probe capable of measuring fast rise times of signals in floating circuits. This 1,300 V

Specification for Conducted Emission Test

Automated Frequency Response Measurement with AFG31000, MDO3000 and TekBench Instrument Control Software APPLICATION NOTE

Guide Version Five techniques for fast, accurate power integrity measurements

Analog Modulation Analysis (AM/FM/φM) Specifications

PRODUCT DATA USES. BENEFITS Normal incidence parameters are determined Fast and accurate measurements. Type 4206A. Type Type 4206T 50 Hz 1.

Keysight Technologies N9398C/F/G and N9399C/F DC Block. Technical Overview

Agilent 8762F Coaxial Switch 75 ohm

High-voltage Differential Probes

R&S FSH Handheld Spectrum Analyzer Where mobility counts

Measurement Setup for Phase Noise Test at Frequencies above 50 GHz Application Note

Differential Probes P6248 P6247 P6246 Datasheet

Keysight Technologies N4985A System Amplifiers

R&S UMS175 Compact Radiomonitoring System High performance for outdoor deployment

20X Low Capacitance Probe P6158 Datasheet

R&S TS8997 Regulatory Test System for Wireless Devices

MXG X-Series Signal Generator N5183B Microwave Analog

High-voltage Differential Probes TMDP THDP THDP P5200A - P5202A - P5205A - P5210A

R&S ZVL Vector Network Analyzer Specifications

R&S ZNA Vector Network Analyzer Specifications

PRODUCT DATA. Falcon Range 1/4-inch Microphone Preamplifier Type 2670

R&S MNT100 RF Interference Locator Specifications

R&S FPC Spectrum Analyzer Specifications

Keysight Technologies RF & Microwave Attenuators. Performance you can count on

Keysight N9311X RF and Microwave Accessory Kit for Low-cost Handheld and Benchtop Solutions. Technical Overview

Agilent 87222C/D/E Coaxial Transfer Switches dc to 26.5, 40, 50 GHz

Signal Generator SMA 100A

Keysight Technologies 423B, 8470B, 8472B, 8473B/C Low Barrier Schottky Diode Detectors

R&S ZVH Cable and Antenna Analyzer Where mobility counts

Don t Let EMI/EMC Compliance Certification Slow You Down TUTORIAL

Application Firmware for Phase Noise Measurements FS-K40

Agilent U9391C/F/G Comb Generators

AC/DC Current Probe TCP0150 Datasheet

Keysight Technologies Differences in Application Between Power Dividers and Power Splitters. Application Note

Agilent 87405B. Preamplifier 10 MHz to 4 GHz. Technical Overview. Features. Benchtop/General Purpose Use

Keysight Technologies N6850A Broadband Omnidirectional Antenna. Data Sheet

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

Keysight Technologies Migrating Balanced Measurements from the

Isolation Addresses Common Sources of Differential Measurement Error

PRODUCT DATA. DC Response Accelerometers Types 4570, 4571, 4572, 4573, 4574, and 4575

Keysight 8474B/C/E Planar-Doped Barrier Diode Detectors 0.01 to 50 GHz. Data Sheet

Keysight E5063A ENA Series Network Analyzer

AC Current Probes CT1 CT2 CT6 Data Sheet

Data Sheet Version R&S RT-ZVCxx Multi-Channel Power Probe Specifications

AC/DC Current Measurement Systems TCPA300, TCP312A, TCP305A, TCP303, TCPA400, TCP404XL Datasheet

Keysight Technologies Enhance EMC Testing with Digital IF. Application Note

Keysight Technologies Electronic Calibration (ECal) Modules for Vector Network Analyzers

Transcription:

R&S ENV216 Two-Line V-Network For disturbance voltage measurements on single-phase EUTs Test & Measurement Data Sheet 03.00

R&S ENV216 Two-Line V-Network At a glance The R&S ENV216 two-line V-network meets the requirements of CISPR 16-1-2, EN 55016-1-2, VDE 0876 and ANSI C63.4 for V-networks with a simulated impedance of (50 µh + 5 Ω ) 50 Ω in the frequency range 9 khz to 30 MHz. A 16 A female connector with protective earth contacts is provided for connecting the EUT. Various models with country-specific connector systems are available. Owing to its compact design and low weight, the R&S ENV216 is ideal for frequently varying applications and especially for on-site disturbance voltage measurements on single-phase EUTs. Note that high leakage currents are produced because of the standard design of these V-networks. The networks should therefore be connected to a low-impedance protective earth system. In uncertain cases, an isolating transformer should be used. In the case of AC supply operation in a range from 90 V to 240 V and 50 Hz to 60 Hz, the operating voltage for the built-in logic circuit is obtained from the AC supply direct. This covers all standard applications. If the EUT is operated with low AC voltages or DC voltages up to 50 V, the logic circuit is powered via an external plug-in power supply that is supplied as standard. Key facts J Frequency range 9 khz to 30 MHz J Power-handling capacity 16 A, constant current J Simulated impedance (50 µh + 5 Ω) 50 Ω in line with CISPR 16-1-2 Amd. 2:2006 J V-network in line with CISPR, EN, VDE, ANSI, FCC Part 15 and MIL-STD-461 D, E and F J Calibrated in line with CISPR 16-1-2 and ANSI C63.4 2

R&S ENV216 Two-Line V-Network Benefits and key features Air-core design and artificial hand The R&S ENV216 two-line V-network is based on air-core inductances and contains an artificial hand. Switch-selectable highpass filter of 150 khz To prevent the measuring receiver from being overdriven by low-frequency spectra of high level, a 150 khz highpass filter can be cut in. Built-in 10 db attenuator pad To ensure standard impedance irrespective of the receiver input attenuation, the R&S ENV216 is equipped with a 10 db attenuator pad. Built-in pulse limiter (can be switched off) A built-in pulse limiter which can be switched off protects the receiver input. Remote control with TTL levels (compatible with Rohde & Schwarz measuring receivers) TTL control inputs that can be driven by controllers and Rohde & Schwarz measuring receivers are provided for remote control in automatic test systems (phase selection and activation of highpass filter). Optocouplers prevent pick-up of external disturbance. Rohde & Schwarz R&S ENV216 Two-Line V-Network 3

Specifications R&S ENV216 two-line V-network Frequency range 9 khz to 30 MHz Simulated impedance phase and magnitude (50 µh + 5 Ω) 50 Ω Error limits in line with CISPR 16-1-2 ±20 % (magnitude), ±11.5 (phase) Isolation 1) 9 khz to 50 khz 50 khz to 30 MHz >0 db to 40 db (increases linearly with logarithm of frequency) >40 db Test path to EUT AC supply voltage If the EUT is operated with AC voltages up to 0 V to 240 V AC + 10 % 90 V and DC voltages up to 50 V, the logic circuit has to be powered via the external plug-in power supply that is supplied as standard. AC supply frequency 50 Hz to 60 Hz ± 5 % DC voltage 0 V to 50 V DC Maximum permissible continuous current country-specific Model 12 16 A Model 13 13 A Model 14 16 A Model 15 15 A Model 16 15 A Test path to measuring receiver Maximum permissible RF disturbance power 1 W from EUT Highpass filter integrated, switch-selectable 150 khz Voltage division factor between EUT and built-in attenuator pad, calibration data supplied 10 db measuring receiver port with V-network Response threshold of built-in pulse limiter can be switched off 140 db (µv) Connectors AC supply input country-specific plug with protective earth contact and 1.8 m cable AC supply voltage input for EUT country-specific socket with protective earth contact RF output N female, 50 Ω Remote control input 25-contact, D-Sub, female Input for artificial hand 4 mm connector, female, with knurled clamp Reference ground connection ground bar with three M4 threads Protective earth connection M6 threaded bolt Connector for external power supply on rear panel, by supplied plug-in power supply DC hollow connector 5.5 mm, 2.1 mm, 10 V to 18 V DC, 250 ma 1) Between AC supply and measuring receiver port. General data Operating temperature range +5 C to +45 C Storage temperature range 40 C to +70 C Dimensions W H D 219 mm 147 mm 350 mm (8.6 in 5.8 in 13.8 in) Weight 5.5 kg (12.1 lb) Electrical safety observe notes in manual in line with EN 61010 EMC in line with IEC/EN 61326 Emission class B, in line with residential environment requirements Immunity in line with industrial environment requirements Rohde & Schwarz R&S ENV216 Two-Line V-Network 4

Ordering information Designation Type Order No. Base unit Two-Line V-Network R&S ENV216 3560.6550.yy Model for Germany (Schuko connector) yy = 12 Model for United Kingdom yy = 13 Model for France yy = 14 Model for China/Australia yy = 15 Model for USA yy = 16 Accessories supplied Manual, calibration data, plug-in power supply Recommended extras Control Cable, 3 m 1) R&S EZ-21 1107.2087.03 Control Cable, 10 m 1) R&S EZ-21 1107.2087.10 150 khz Highpass 2) R&S EZ-25 1026.7796.03 1) 25-wire remote-control cable: control by test receivers of series R&S ESxS, R&S ESIBx, R&S ESPIx, R&S ESCI and R&S ESUx (male-to-male, wired 1:1; two required for shielded chambers). 2) Required for high disturbance voltages below 150 khz, e.g. for disturbance voltage measurement in line with EN 50065, Part 1. Country-specific connector models Germany as well as Austria, Finland, the Netherlands, Norway, Russia, Sweden; occasionally: Portugal, Spain UK, Ireland, Hong Kong, Malaysia, Singapore France, Belgium and Czech Republic China, Australia, New Zealand USA, Canada, Japan, Korea, Taiwan, Mexico, Central America Rohde & Schwarz R&S ENV216 Two-Line V-Network 5

Service you can rely on J In 70 countries J Person-to-person J Customized and flexible J Quality with a warranty J No hidden terms About Rohde & Schwarz Rohde & Schwarz is an independent group of companies specializing in electronics. It is a leading supplier of solutions in the fields of test and measurement, broadcasting, radiomonitoring and radiolocation, as well as secure communications. Established 75 years ago, Rohde & Schwarz has a global presence and a dedicated service network in over 70 countries. Company headquarters are in Munich, Germany. Regional contact Europe, Africa, Middle East +49 1805 12 42 42* or +49 89 4129 137 74 customersupport@rohde-schwarz.com North America 1-888-TEST-RSA (1-888-837-8772) customer.support@rsa.rohde-schwarz.com Latin America +1-410-910-7988 customersupport.la@rohde-schwarz.com Asia/Pacific +65 65 13 04 88 customersupport.asia@rohde-schwarz.com Certified Quality System ISO 9001 DQS REG. NO 1954 QM Certified Environmental System ISO 14001 DQS REG. NO 1954 UM More information at www.rohde-schwarz.com Rohde & Schwarz GmbH & Co. KG Mühldorfstraße 15 81671 München Phone +49 89 41 290 Fax +49 89 41 29 121 64 www.rohde-schwarz.com R&S is a registered trademark of Rohde & Schwarz GmbH & Co. KG Trade names are trademarks of the owners Printed in Germany (ch) PD 5214.0299.32 Version 03.00 September 2008 R&S ENV216 Data without tolerance limits is not binding Subject to change *0.14 /min within German wireline network; rates may vary in other networks (wireline and mobile) and countries.