NITTERHOUSE CONCRETE PRODUCTS, INC Molly Pitcher Highway South Chambersburg, PA

Similar documents
A. Extent of structural precast concrete work is shown on drawings and in schedules.

SECTION ARCHITECTURAL PRECAST CONCRETE PART 1 - GENERAL

1. Architectural precast concrete cladding units.

GUIDE SPECIFICATION FOR ARCHITECTURAL PRECAST CONCRETE (PCI MNL 117)

SECTION ARCHITECTURAL PRECAST CONCRETE

10.2 GUIDE SPECIFICATION FOR ARCHITECTURAL/STRUCTURAL PRECAST CONCRETE

SECTION PRECAST HOLLOW CORE PLANKS

SECTION STRUCTURAL STEEL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

3400 Tectura Designs Precast Concrete

SECTION METAL FABRICATIONS

SECTION STRUCTURAL STEEL. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

14 March 2016 City Hall Station Renovations Bid Documents 15 th Street Station Phase Station Improvements SECTION PRECAST CONCRETE

SECTION BULLET- RESISTANT DOORS

MANUFACTURING & INSTALLATION GUIDELINES & GUIDE SPECIFICATIONS for STRUCTURAL PRECAST

BPDL Architectural precast concrete specifications USA TESTING AND INSPECTION A. Testing by Independent Agency : Materials and workmanship furn

SPECIFICATIONS FOR THE MANUFACTURE AND DESIGN OF PRECAST THREE SIDED ARCH STRUCTURES, WINGWALLS AND HEADWALLS

EMMEGI ARCHITECTURAL FENCING MASTER SPECIFICATION SECTION METAL FENCING, GATES & RAILING SYSTEM PART 1 GENERAL

SECTION 1085 PRECAST REINFORCED CONCRETE BOX CULVERT

1.1 RELATED DOCUMENTS

Section 914. JOINT AND WATERPROOFING MATERIALS

2016 Specification Treads, Base, Stringers and other Amenities Wausau Tile Precast Epoxy Terrazzo

SECTION THERAPEUTIC POOL ACCESSORIES

SECTION PRECAST CONCRETE SECTIONAL MANHOLES

SECTION COUNTERTOPS ecox PART 1 GENERAL

1.1 SUMMARY. A. This Section includes the following: 1. Loose steel lintels. 2. Shelf angles. 3. Metal floor plate. 4. Pipe bollards.

PART MATERIALS. Section Fencing Materials. Description

Standard Specifications

Large Scale CalArc Pavers for Sand-Set Pedestrian Use Installations

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

STRUCTURAL STEEL AND ALUMINUM PART 1 - GENERAL 1.01 SCOPE:

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

SECTION PRECAST CONCRETE STRUCTURES

Edgerail Aluminum Bridge Railing System Specification & Installation Instructions

IGGA Guide Specification: Dowel Bar Retrofit (DBR) Introduction

B. Design Mixtures: For each precast concrete mixture. Include compressive strength and, if required, water-absorption tests.

SECTION SHEET METAL FLASHING AND TRIM

SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

CHAPTER 10 MICHIGAN DESIGN MANUAL BRIDGE DESIGN (SI) SHOP DRAWING REVIEW TYPES OF SHOP DRAWINGS Structural Steel

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

B. Installation Instructions. Provide installation instructions, including any special equipment, to address the following.

Suggested Specification for Preparing Hot-Dip Galvanized Steel Surfaces for Painting Revised February 2002

MANHOLES PART I: GENERAL. A. Precast Concrete Manholes

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION

D. Thermally Sprayed Metallic Coating (Flame Spray): STD SPEC

SECTION HOLLOW METAL DOORS AND FRAMES

WAL-MART SUPERCENTER # ; Milwaukie, OR: SPECIFICATIONS. Revisions to Specification Fence

SECTION INTERIOR SIGNAGE

STEEL PIPE GUIDERAIL 01/01/

How to Estimate the Cost of a. Precast Concrete Parking Structure

SECTION CHAIN LINK FENCING

SPECS. SPC-1

SECTION MANHOLES

SECTION CONCRETE REINFORCEMENT FOR STEAM UTILITY DISTRIBUTION

AESS Documents prepared by CISC ad hoc committee

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

SECTION HOLLOW METAL DOORS AND FRAMES

Ash Brook Golf Course Scotch Plains, New Jersey

W DESIGN ASSOCIATES. Consulting Engineers & Architects McCook, Nebraska Hastings, Nebraska 68901

CONSTRUCTION SPECIFICATION FOR PRECAST REINFORCED CONCRETE BOX CULVERTS AND BOX SEWERS

4.1. Foremen 4.2. Concrete plant manager 4.3. Concrete plant operator 4.4. Personnel performing saw cutting and joint sealing

ALUMINUM PIPE GUIDERAIL 01/01/

Storage and Installation of welded LL Hollow Metal Door Frames in Steel Studs

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018

GUIDELINE SPECIFICATIONS

SECTION 58 PRECAST CONCRETE BOX CULVERT. This work consists of furnishing and installing Pre-cast Concrete Box Culverts.

UNDERGROUND UTILITY TRENCHES AND VAULTS Page 1 of 6 ADDENDUM #1

4. Metal roof jacks at penetrations and attachments

Stop Gates & Stop Logs. Series 500. ine. Manufacturing high quality gates since 1977

To: New York State Department of Transportation ENGINEERING INSTRUCTION. Approved:

HOLLOW METAL DOORS AND FRAMES

B. Terracotta Precast Facade Assembly consisting of single-leaf, through body color terracotta clay tiles.

UNISTRUT CORPORATION 2. AREA DIRECTLY ABOVE THE SUPPORT TO BE FREE AND CLEAR OF ALL OBSTRUCTIONS. 3. EXISTING STRUCTURE TO BE CHECKED BY OTHERS.

UNISTRUT CORPORATION 2. AREA DIRECTLY ABOVE THE SUPPORT TO BE FREE AND CLEAR OF ALL OBSTRUCTIONS. 3. EXISTING STRUCTURE TO BE CHECKED BY OTHERS.

StormTrap Guide Specification. StormTrap 2 SingleTrap on Aggregate Foundation Groundwater BELOW Invert Revised 11/30/17

SECTION MANUFACTURED CASEWORK

Essex County College - West Essex Campus Addition And Renovations dlb # / SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

OSE Submittal July 20, 2018

SECTION SITE FURNISHINGS FOR CFCRT. 1. American Society for Testing and Materials (ASTM).

C A R T E R W A T K I N S A S S O C I A T E S A R C H I T E C T S, I N C.

b. B aluminum and aluminum-alloy extruded bar, rod, wire, shape and tube

Product Guide Specification

C. HMMA 863: Guide Specifications for Detention Security Hollow Metal Doors and Frames

SECTION CABLE TRAYS

City of Regina Standard Construction Specification SECTION 2660 CHAIN LINK FENCE

Series 6000 Vinyl Single Hung

SECTION BASIC MATERIALS AND METHODS

CONSTRUCTION SPECIFICATION FOR MAINTENANCE HOLE, CATCH BASIN, DITCH INLET, AND VALVE CHAMBER INSTALLATION

Series 9000 Vinyl Single Hung

SECTION Display Case Door Series 1301-CM

Architecturally Exposed Structural Steelwork (AESS) Sample Specification (for Engineers)

TABLE OF CONTENTS. 1.0 Scope. 2.0 References. 3.0 Definitions. 4.0 Submission and Design Requirements. 5.0 Materials 5.1 General 5.

The Manitoba Water Services Board SECTION Standard Construction Specifications September 2013 Page 1 of 8

SECTION TRAFFIC SIGNAGE

SECTION CHAIN LINK FENCING AND GATES AND SOFTBALL BACKSTOP

Series 9000 Vinyl Fixed Window

A. Provide all finish carpentry needed for a complete and proper installation.

5/16" Flange nut. Bolt Keeper Plate (8" Sq. SYS.) (3) 1/2" x 3" Hex head connector zinc plated bolt w/ washers and nut. Anchor 3" sq. 7 Ga.

B. See Division 05 Section "Pipe and Tube Railings" for metal pipe and tube railings.

A. Compatibility: Products shall be suitable for piping service fluids, materials, working pressures, and temperatures.

Item 550 Chain Link Fence

Transcription:

NITTERHOUSE CONCRETE PRODUCTS, INC. 2655 Molly Pitcher Highway South Chambersburg, PA 17201 717-267-4505 GUIDE SPECIFICATION FOR ARCHITECTURAL PRECAST CONCRETE INDEX Page PART I - GENERAL...1 A. DESCRIPTION...1 B. QUALITY ASSURANCE... 1-2 C. SUBMITTALS... 2-3 PART II - PRODUCTS...4 A. MATERIALS... 4-5 B. MIXES...5 C. MANUFACTURING... 5-6 PART III - EXECUTION...6 A. JOBSITE CONDITIONS...6 B. PRODUCT DELIVERY, HANDLING AND STORAGE...6 C. ERECTION... 6-7 D. REPAIR...7 E. CLEANING... 7-8 F. PROTECTION...8 G. WARRANTY...8 This Guide Specification is intended for the use of professional personnel competent to evaluate the significance and limitations of its contents, and who will accept responsibility for the application of the material it contains.

i

PART I - GENERAL A. DESCRIPTION 1. Related Work Specified Elsewhere: a. Precast Structural Concrete: Section b. Cast-in-place Concrete: Section c. Concrete Reinforcement: Section d. Structural Steel Framing: Section e. Miscellaneous Steel: Section f. Steel Metal Work: Section g. Waterproofing: Section h. Caulking and Sealants: Section i. Receivers (reglets) for flashings specified under: Section j. Painting: Section k. Insulation: Section l. Glass and Glazing: Section 2. Testing a. Testing in-house by precast manufacturer. b. Independent testing at owner's expense. B. QUALITY ASSURANCE 1. Qualifications of Manufacturer a. Manufacturer shall have a minimum of five (5) years of production experience in architectural precast concrete work of the quality and scope required on this project. b. Manufacturer shall be a member of the Precast/Prestressed Concrete Institute and PCI certified. 2. Qualifications of Erector a. Erection of precast concrete panels shall be performed by an established firm regularly engaged for at least two (2) years in the erection of precast concrete panels of sizes similar to those required on this project. b. Perform inspection of panels under the supervision of a foreman employed by the erection firm for this type of work. 3. Qualifications of Welders and Tackers: a. Welder qualifications shall be in accordance with AWS D 1.1 4. Testing: a. All testing shall be performed by the manufacturer s in-house quality control inspectors and in accordance with all provisions in MNL-117, Manual for Quality Control for Plants and Production of Products as published by PCI. 5. Allowable Casting Tolerances Manufacture wall panels so the dimensional tolerances should be as follows: a. 10 ft. or under... ± 1/8 in. b. 10 ft. to 20 ft...+ 1/8 in. - 3/16 in. c. 20 ft. to 30 ft... ± 1/4 in. d. Each additional 10 ft.... ± 1/16 in. per 10 ft. e. Total thickness or flange thickness...- 1/8 in., + 1/4 in. f. Angular variation of plane of side mold...± 1/32 in. per 3 in. of depth or ± 1/16 in., whichever is greater

Guide Specification Page 1 g. Variation from square or designated skew (difference in length of the two (2) diagonal measurements)...1/8 in. per 6 ft. of diagonal or (whichever is greater)... ±1/2 in. h. Length and width of block-outs and openings within one (1) unit... ± 1/4 in. i. Location and dimensions of block-outs hidden from view and used for HVAC and utility penetration... ± 3/4 in. j. Dimensions of haunches... ± 1/4 in. k. Haunch bearing surface deviation from specified plane... ± 1/8 in. l. Difference in relative position of adjacent haunch bearing surfaces from specified relative position... ± 1/4 in. m. Bowing... L/360, max. 1 in. n. Local smoothness...1/4 in. in 10 ft. o. Warping...1/16 in. per ft. (of distance from nearest adjacent corner) p. Location of window opening within the panel... ± 1/4 in. q. Position of plates... ± 1 in. r. Tipping and flushness of plates... ± 1/4 in. s. Position tolerances. For cast-in items measured from datum line location, as shown on approved erection drawings i. Inserts... ± 1/2 in. ii. iii. Handling devices... ± 3 in. Reinforcing steel and welded wire fabric... ± 1/4 in. where position has structural implications or affects concrete cover, otherwise... ± 1/2 in. iv. Tendons... ± 1/4 in. v. Flashing reglets... ± 1/4 in. vi. Flashing reglets at edge of panel... ± 1/8 in. vii. Reglets for glazing gaskets... ± 1/8 in. viii. Groove width for glazing gaskets... ± 1/8 in. ix. Electrical outlets, hose bibs, etc... ± 1/2 in. x. Haunches... ± 1/4 in. 6. Source of Quality Control a. Water absorption test of coarse aggregate: ASTM C127. b. Water absorption test of fine aggregates: ASTM C128. c. Water absorption test for precast panel: ASTM C642. d. Curing test specimens: ASTM V192. C. SUBMITTALS 1. Samples a. Before starting the manufacture of precast concrete panels, submit for review to the Architect/Engineer one (1) sample which represents the finished product and which clearly indicates the color and texture of the panels. Page 2

Guide Specification b. Samples are to be 12" x 12" face size by 1 1/2" thick. c. Label each sample to indicate name of manufacturer and finish code. d. After standard samples are accepted for color and texture, submit three (3) mock-up panels at least 4'-0" x 5'-0" for review of the Architect/Engineer to show the extreme maximum variations which may occur in the color and texture of the production pieces. e. The mock-up panels are to be the standard of quality for precast concrete panel work, when they are accepted by the Architect/Engineer. f. The Architect/Engineer should visit the precast plant shortly after the start-up of production in order to inspect actual production pieces. 2. Shop Drawings General Contractor shall expedite the submittal with the Architect to conform with allotted shop drawing approval time, shown on the precast concrete supplier's order acknowledgment. a. The content shall be as follows: i Unit shapes (elevations and sections) and dimensions. ii. Finishes iii. Joint and connection details. iv. Lifting and erection inserts. v. Location, dimensional tolerances and details of anchorage devices that are embedded in or attached to structure or other construction. vi. Other items cast into panels. vii. Handling procedures, plans and/or elevations showing panel location and sequence of erection for special conditions. viii. Relationship to adjacent material b. Show location of unit by same identification mark placed on panel. c. Individual panel details may be submitted at the request of the Architect/Engineer. It is recognized that a review of the panel details prior to actual release for production will greatly impact the construction schedule. 3. Test Reports a. Submit, upon request, reports on materials, compressive strength tests on concrete and water absorption test on units. 4. Design Calculations a. Submit upon request structural design calculations. 5. Design Modifications a. Submit design modifications necessary to meet performance requirements and field coordination. b. Variations in details or materials shall not adversely affect the appearance, durability or strength of the units. c. Maintain general design concept without altering the size of members, profiles and alignment.

Guide Specification Page 3 PART II - PRODUCTS A. MATERIALS 1. Portland Cement a. ASTM C150, Type I or III cement. White or gray. b. Use same brand, type and source of supply of cement for all exposed precast concrete. 2. Air Entraining Agent ASTM C979 3. Aggregates a. Facing and Backing Aggregates i. ASTM C33 and ASTM C330 ii. Provide fine and coarse aggregates for each type of exposed finish from a single source (pit or quarry) for the entire job. They shall be clean, hard, strong, durable and inert, free of staining or deleterious material. 4. Water a. Free from foreign materials in amounts harmful to concrete. Potable water is ordinarily acceptable. 5. Reinforcing Steel a. Reinforcing bars i. New billet deformed steel, grade 40 or grade 60, as per ASTM A615. ii. Weldable deformed steel, as per ASTM A706. iii. Galvanized reinforcing bars, as per ASTM A775. iv. Epoxy coated reinforcing bars, as per ASTM A775. b. Welded wire fabric i. Welded steel, as per ASTM A185 ii. Welded deformed steel, as per ASTM A497 iii. Epoxy coated welded wire fabric, as per ASTM A884. c. Fabricated steel bar or rod mats, as per ASTM A184 d. Prestressing strand, as per ASTM A416, grade 270. 6. Cast-in Anchors a. Materials i. Structural steel, as per ASTM A36 ii. Stainless steel, as per ASTM A666, type 304, grade. iii. Carbon Steel plate, as per ASTM A283, grade. iv. Malleable iron castings, as per ASTM A47, grade. v. Carbon steel castings, as per ASTM A27, grade 60-30. vi. Bolts, as per ASTM A307 or A325. vii. Welded headed studs, as per AWS D1.1, Chapter 4, Part F. b. Finish i. Shop primer: FS TT-P-86, oil base paint, type I or SSPC-paint 14, or manufacturer's standard.

ii. Galvanized: hot dip galvanized (ASTM A153), electroplated or metallized. iii. Cadmium coating, as per ASTM A165. iv. Zinc rich coating: MIL-P-21035, self curing, one (1) component, sacrificial organic coating. Page 4 Guide Specification 8. Receivers for Flashing: 28 ga. galvanized, stainless, copper or polyvinyl chloride extrusions. 9. Grout a. Cement grout: Portland cement, sand and water sufficient for placement and hydration. b. Non-shrink grout: Premixed, packaged ferrous and non-ferrous aggregate shrink resistant grout. c. Epoxy-resin grout: Two-component mineral-filled epoxy-polysulfide, FS MMM-G- 560 type, grade C. 11. Bearing Pads a. Chloroprene (Neoprene): Conform to Division II, Section 25 of AASHTO Standard Specifications for Highway Bridges. b. Plastic: Multi-monomer plastic strips shall be non-leaching and support construction loads with no visible overall expansion. c. Tetraflouroethylene (TFE) reinforced with glass fibers and applied to stainless or structural steel plates. B. MIXES 1. Water-Cement Ratio: Maximum of five (5) gallons of water per 94 lbs. of cement. 2. Air Entrainment: Minimum 3% not more than 6% when concrete is placed. 3. Salt: Calcium Chloride and other ionic compounds which are electrolytic will not be permitted in concrete mix. 4. Super Plasticizer: Can be used at manufacturer's option. C. MANUFACTURING 1. Minimum ultimate compressive strength of precast concrete after 28 days, shall be a minimum of 5,000 psi. 2. Water absorption of architectural precast concrete panels shall not exceed a maximum of 6% by weight. 3. Compression test for precast concrete a. Number of tests: Make compression test for each day's production of each type of concrete. Two test cylinders should be made for each load of concrete delivered to the casting bed. b. Specimens i. Provide test specimens for compression test at 7 and 28 days. ii. Obtain concrete for specimens from the actual production batch they will represent.

iii. 6" x 12" (or 4" x 8") molded concrete cylinder meeting applicable requirements of ASTM C31. iv. 2" x 2" molded or sawed cubes. Test results will be reduced by 20%. 4. Finishes a. Exposed face surfaces of precast concrete panels: Finished to match the approved sample panel. b. Back surfaces of precast concrete panels: Should match approved sample panel. Page 5 Guide Specification 5. Curing (Wet Cast) a. Form cure precast units until a sufficient stripping strength has developed. b. Maintain precast units at a minimum temperature of 33 F until 50% of the design strength has been reached. 6. Panel Identification a. Mark each precast concrete panel to correspond to the code markings appearing on the shop drawings for panel location. Do not mark on the finish surfaces. b. Maintain a record of casting date. PART III - EXECUTION A. JOBSITE CONDITIONS 1. Before starting to erect the precast concrete panels, the General Contractor shall verify that the structure and anchorage inserts not within the tolerances required to erect the panels have been corrected. 2. Determine field conditions before commencing erection. B. PRODUCT DELIVERY, HANDLING AND STORAGE 1. Delivery and Handling a. Deliver all architectural precast concrete units to project site in such quantities and at such times as to assure the continuation of erection. b. Handle and transport units in a position consistent with their shape and design in order to avoid stresses which would cause cracking or damage. c. Lift or support units only at the points shown on the shop drawings. d. Place non-staining resilient spacers of even thickness between each unit. e. Support units during shipment on non-staining shock-absorbing material. f. Do not place units directly on the ground. 2. Storage at Jobsite a. Store and protect units to prevent contact with soil, staining and physical damage. b. Store units, unless otherwise specified, with non-staining resilient supports located in the same positions as when transported. c. Store units on firm, level and smooth surfaces to prevent cracking, distortion, warping or other physical damage. d. Place stored units so that identification marks are discernible and so that product can be inspected.

C. ERECTION 1. Clear, well-drained unloading areas and road access around and in the structure shall be provided and maintained by the General Contractor, to include providing and maintaining accessible roadways in which cranes and trucks can maneuver under their own power. 2. General Contractor shall erect adequate barricades, warning lights or signs to safeguard traffic in the immediate area of hoisting and handling operations. Any overhead obstructions interfering with the erection must be removed by others and any underground equipment installed where cranes and trucks must maneuver is installed at the risk of the trade requiring them and be protected by that contractor. Page 6 Guide Specification 3. Set precast concrete units level, plumb, square and true within the allowable tolerances. The General Contractor shall provide true, level bearing surfaces on all field placed concrete which are to receive precast concrete units. The General Contractor shall be responsible for providing offset lines and elevations in sufficient detail to allow installation. 4. Provide temporary supports and bracing, as required, to maintain position, stability and alignment as units are being permanently connected. 5. Non-cumulative tolerances for location of precast concrete units shall be as follows: a. Plan location from building grid datum... ± 1/2 in. b. Plan location from centerline of steel...± 1/2 in. c. Top elevation for nominal top elevation i. Exposed individual panel... ± 1/4 in. ii. Non-exposed individual panel... ± 1/2 in. iii. Exposed relative to adjacent panel... 1/4 in. iv. Non-exposed relative to adjacent panel... 1/2 in. d. Support elevation from nominal elevation i. Maximum low... 1/2 in. ii. Maximum high... 1/4 in. e. Maximum plumb variation over height of structure or 100 ft., whichever is less...1 in. f. Plumb in any 10 ft. of element height... 1/4 in. g. Maximum job in alignment of matching edges...1/4 in. h. Joint width (governs over joint taper)... ± 1/4 in. i. Joint taper maximum... 3/8 in. j. Joint taper over 10 ft. in length... 1/4 in. k. Maximum jog in alignment of matching faces... 1/4 in. l. Differential bowing or camber as erected between adjacent members of the same design... 1/4 in. 6. Set non-loadbearing units dry without mortar, attaining specified joint dimension with, steel or plastic cement spacing shims.

7. Fasten precast concrete units in place by bolting and/or welding, completing drypacked joints, grouting sleeves and pockets and/or placing cast-in-place concrete joints, as indicated on approved erection drawings. 8. Temporary lifting and handling devices cast into the precast concrete units shall be completely removed, or if protectively treated remove only where they interfere with the work of any other trade. D. REPAIR 1. Repair exposed exterior surface to match color and texture of surrounding concrete. 2. Adhere large patch to hardened concrete with bonding agent. E. CLEANING 1. Precast concrete panels will be clean upon completion of erection and leaving the job site. Guide Specification Page 7 2. After installation and joint treatment the General Contractor should protect the architectural precast concrete panels against damage and maintain the cleanliness of the panels. Any final wash-down of the precast architectural panels should be the responsibility of the General Contractor. F. PROTECTION 1. All work and materials of other trades shall be adequately protected by the Erector at all times. 2. A fire extinguisher, of an approved type and in operating condition, shall be located within reach of all burning and welding operations at all times. G. WARRANTY 1. The Precast Concrete Manufacturer shall guarantee the precast concrete products against defects in material and workmanship, for a period of one (1) year, after acceptance of the units by the owner.

lwh\engineer\guide spec architectural.doc Issued; 08/30/90 Rev: 12/22/00 Page 8