A. Extent of structural precast concrete work is shown on drawings and in schedules.

Similar documents
SECTION ARCHITECTURAL PRECAST CONCRETE PART 1 - GENERAL

SECTION ARCHITECTURAL PRECAST CONCRETE

1. Architectural precast concrete cladding units.

SECTION STRUCTURAL STEEL FRAMING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION CONCRETE REINFORCEMENT FOR STEAM UTILITY DISTRIBUTION

14 March 2016 City Hall Station Renovations Bid Documents 15 th Street Station Phase Station Improvements SECTION PRECAST CONCRETE

W DESIGN ASSOCIATES. Consulting Engineers & Architects McCook, Nebraska Hastings, Nebraska 68901

2016 Specification Treads, Base, Stringers and other Amenities Wausau Tile Precast Epoxy Terrazzo

B. Design Mixtures: For each precast concrete mixture. Include compressive strength and, if required, water-absorption tests.

SECTION PRECAST HOLLOW CORE PLANKS

NITTERHOUSE CONCRETE PRODUCTS, INC Molly Pitcher Highway South Chambersburg, PA

Section 914. JOINT AND WATERPROOFING MATERIALS

BPDL Architectural precast concrete specifications USA TESTING AND INSPECTION A. Testing by Independent Agency : Materials and workmanship furn

KANSAS DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION TO THE STANDARD SPECIFICATIONS, 1990 EDITION

SPECIFICATIONS FOR THE MANUFACTURE AND DESIGN OF PRECAST THREE SIDED ARCH STRUCTURES, WINGWALLS AND HEADWALLS

SECTION STRUCTURAL STEEL. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

SECTION METAL FABRICATIONS

Standard Specifications

PART MATERIALS. Section Fencing Materials. Description

SECTION BULLET- RESISTANT DOORS

1.1 RELATED DOCUMENTS

1.1 SUMMARY. A. This Section includes the following: 1. Loose steel lintels. 2. Shelf angles. 3. Metal floor plate. 4. Pipe bollards.

SECTION COUNTERTOPS ecox PART 1 GENERAL

GUIDE SPECIFICATION FOR ARCHITECTURAL PRECAST CONCRETE (PCI MNL 117)

B. Installation Instructions. Provide installation instructions, including any special equipment, to address the following.

10.2 GUIDE SPECIFICATION FOR ARCHITECTURAL/STRUCTURAL PRECAST CONCRETE

SECTION 58 PRECAST CONCRETE BOX CULVERT. This work consists of furnishing and installing Pre-cast Concrete Box Culverts.

MANUFACTURING & INSTALLATION GUIDELINES & GUIDE SPECIFICATIONS for STRUCTURAL PRECAST

SECTION PRECAST CONCRETE SECTIONAL MANHOLES

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

WAL-MART SUPERCENTER # ; Milwaukie, OR: SPECIFICATIONS. Revisions to Specification Fence

Large Scale CalArc Pavers for Sand-Set Pedestrian Use Installations

TENANT IMPROVEMENT 16 FEBRUARY WEST 27TH STREET, 4TH FLOOR 100% CD OWNER/BID ADD 1-03/08/2018

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

3400 Tectura Designs Precast Concrete

4.1. Foremen 4.2. Concrete plant manager 4.3. Concrete plant operator 4.4. Personnel performing saw cutting and joint sealing

StormTrap Guide Specification. StormTrap SingleTrap on Pad Foundation Groundwater BELOW Invert Revised 11/21/18

SECTION 1085 PRECAST REINFORCED CONCRETE BOX CULVERT

IGGA Guide Specification: Dowel Bar Retrofit (DBR) Introduction

SECTION PRECAST CONCRETE STRUCTURES

C A R T E R W A T K I N S A S S O C I A T E S A R C H I T E C T S, I N C.

SECTION HOLLOW METAL DOORS AND FRAMES

Lumicor CSI Specification Guide Open Format Section Solid Polymer Fabrication

CVO/169897A OCTOBER 29, GROUT

UNDERGROUND UTILITY TRENCHES AND VAULTS Page 1 of 6 ADDENDUM #1

To: New York State Department of Transportation ENGINEERING INSTRUCTION. Approved:

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

PREFOAM - PERMANENT STADIUM SEATING RISER SYSTEM FOR FLOOR MONTED SEATING PART 1 GENERAL DESCRIPTION

EMMEGI ARCHITECTURAL FENCING MASTER SPECIFICATION SECTION METAL FENCING, GATES & RAILING SYSTEM PART 1 GENERAL

SECTION MANUFACTURED CASEWORK

SECTION MANHOLES

SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

StormTrap Guide Specification. StormTrap 2 SingleTrap on Aggregate Foundation Groundwater BELOW Invert Revised 11/30/17

D. Thermally Sprayed Metallic Coating (Flame Spray): STD SPEC

CITY OF PITTSBURG ENGINEERING DEPARTMENT CONTRACT NO A WATER TREATEMENT PLANT CAPITAL IMPROVEMENTS PHASE 1A ADDENDUM #1 FENCE AND DITCH AUGUST

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENT 1073 PRECAST CONCRETE CERTIFICATION PROGRAM JULY 20, 2018

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

Product Guide Specification

SECTION SAND CUSHION TERRAZZO FLOORING

Collins Engineers Palmetto Islands County Park Boardwalk Repairs 03/28/2014 SECTION ROUGH CARPENTRY

SECTION TRAFFIC SIGNAGE

B. Shop Drawings: Include elevations, door edge details, frame profiles, metal thicknesses, preparations for hardware, and other details.

OSE Submittal July 20, 2018

SECTION 39 - MANHOLES TABLE OF CONTENTS

SECTION INTERIOR SIGNAGE

SECTION MANHOLES

SECTION MASONRY ANCHORAGE AND REINFORCEMENT. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION SITE FURNISHINGS FOR CFCRT. 1. American Society for Testing and Materials (ASTM).

CONSTRUCTION SPECIFICATION FOR PRECAST REINFORCED CONCRETE BOX CULVERTS AND BOX SEWERS

UNISTRUT CORPORATION 2. AREA DIRECTLY ABOVE THE SUPPORT TO BE FREE AND CLEAR OF ALL OBSTRUCTIONS. 3. EXISTING STRUCTURE TO BE CHECKED BY OTHERS.

UNISTRUT CORPORATION 2. AREA DIRECTLY ABOVE THE SUPPORT TO BE FREE AND CLEAR OF ALL OBSTRUCTIONS. 3. EXISTING STRUCTURE TO BE CHECKED BY OTHERS.

C. HMMA 863: Guide Specifications for Detention Security Hollow Metal Doors and Frames

JVI Vector Connector

Item 550 Chain Link Fence

Edgerail Aluminum Bridge Railing System Specification & Installation Instructions

Architecturally Exposed Structural Steelwork (AESS) Sample Specification (for Engineers)

SECTION STEEL LIGHTING STANDARDS. 1. Electrical conduit and fittings; Section

STRUCTURAL STEEL AND ALUMINUM PART 1 - GENERAL 1.01 SCOPE:

GUIDELINE SPECIFICATIONS

CHAPTER 10 MICHIGAN DESIGN MANUAL BRIDGE DESIGN (SI) SHOP DRAWING REVIEW TYPES OF SHOP DRAWINGS Structural Steel

TABLE OF CONTENTS. 1.0 Scope. 2.0 References. 3.0 Definitions. 4.0 Submission and Design Requirements. 5.0 Materials 5.1 General 5.

SECTION CHAIN LINK FENCING

1. INTRODUCTION 2. REFERENCE SPECIFICATIONS. Page -1- Bonding and Grouting

SECTION THERAPEUTIC POOL ACCESSORIES

Essex County College - West Essex Campus Addition And Renovations dlb # / SECTION EXPANSION FITTINGS AND LOOPS FOR HVAC PIPING

A. Compatibility: Products shall be suitable for piping service fluids, materials, working pressures, and temperatures.

SECTION ARCHITECTURAL WOOD CASEWORK

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

MANHOLES PART I: GENERAL. A. Precast Concrete Manholes

AMPCO PRODUCTS, INC. TECHNICAL SPECIFICATIONS SOLID PHENOLIC CORE TOILET COMPARTMENTS

Corrosion-Resistant Coated Dowel Bars

B. Products furnished, but not installed, under this Section include the following:

C. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available.

AMENDMENTS Manual of STANDARD SPECIFICATIONS. Adopted by Standard Specifications Committee. Amendment. No. 6. Published by

SECTION Display Case Door Series 1301-CM

SECTION HOLLOW METAL DOORS AND FRAMES

DIVISION 11 EQUIPMENT SECTION PHOTO DARKROOM FUME EXHAUST VENT-HOODS

A. Deviation from this standard must be approved by the Project Architect.

Product Guide Specification

CONSTRUCTION SPECIFICATION FOR MAINTENANCE HOLE, CATCH BASIN, DITCH INLET, AND VALVE CHAMBER INSTALLATION

Transcription:

SECTION 03 41 00 - STRUCTURAL PRECAST CONCRETE PART 1 GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of Contract, including General and Supplementary Conditions and Division 1 specification sections, apply to work of this Section. 1.2 DESCRIPTION OF WORK A. Extent of structural precast concrete work is shown on drawings and in schedules. B. Related Work Specified Elsewhere: 1. Section 04 05 13 - Mortar. 2. Section 07 92 00 - Joint sealants. 1.3 QUALITY ASSURANCE A. Codes and Standards: Comply with provisions of following codes, specifications and standards, except as otherwise indicated: 1. ACI 301 "Specifications for Structural Concrete for Buildings. 2. ACI 318 "Building Code Requirements for Reinforced Concrete. 3. Concrete Reinforcing Steel Institute, "Manual of Standard Practice. 4. Prestressed Concrete Institute MNL 116, "Manual for Quality Control for Plants and Production of Precast Concrete Products. 1.4 SUBMITTALS A. Product Data: Submit manufacturer's specifications and instructions for manufactured materials and products. Include manufacturer's certifications and laboratory test reports as required. B. Shop Drawings: 1. Submit shop drawings showing complete information for fabrication and installation of precast concrete units. Indicate member dimensions and cross-section; location, size and type of reinforcement, including special reinforcement and lifting devices necessary for handling and erection. 2. Indicate layout, dimensions, and identification of each precast unit corresponding to sequence and procedure of installation. Indicate welded connections by AWS standard symbols. Detail inserts, connections and joints, including accessories and construction at openings in precast units. 3. Include erection procedure for precast units and sequence of erection. C. Calculations: Provide complete design calculations prepared by a registered engineer, licensed in State where project is erected. STRUCTURAL PRECAST CONCRETE 03 41 00-1

1.5 DELIVERY, STORAGE AND HANDLING A. Deliver precast concrete units to project site in such quantities and at such times assure continuity of installation. Store units at project site to prevent cracking, distortion, staining, or other physical damage, and so that markings are visible. Lift and support units at designated lift points. B. Deliver anchorage items which are to be imbedded in other construction before start of such work. Provide setting diagrams, templates, instructions and directions as required for installation. PART 2 PRODUCTS 2.1 PRESTRESSING TENDONS A. Uncoated, 7-wire stress-relieved strand complying with ASTM A416, Grade 250. 2.2 CONCRETE MATERIALS A. Portland Cement: ASTM C150, Type I or III. B. Aggregates: ASTM C33, or C330. C. Water: Drinkable and free from foreign materials in amounts harmful to concrete and imbedded steel. 2.3 CONNECTION MATERIALS A. Steel Plates: Structural quality, hot-rolled carbon steel, ASTM A283, Grade C. B. Steel Shapes: ASTM A36. C. Anchor Bolts: ASTM A307, low-carbon steel bolts, regular hexagon nuts and carbon steel washers. D. Accessories: Provide clips, hangers, and other accessories required for installation of project units and for support of subsequent construction or finishes. 2.4 BEARING PADS A. Elastomeric Pads: AASHTO M 251, plain, vulcanized, 100 percent polychloroprene (neoprene) elastomer, molded to size or cut from a molded sheet, 50 to 70 Shore A durometer, minimum tensile strength 2250 psi per ASTM D 412. B. Random-Oriented, Fiber-Reinforced Elastomeric Pads: Preformed, randomly oriented synthetic fibers set in elastomer. Surface hardness of 70 to 90 Shore A durometer. C. Cotton-Duck-Fabric-Reinforced Elastomeric Pads: Preformed, horizontally layered cotton-duck fabric bonded to an elastomer. Surface hardness of 80 to 100 Shore A durometer. D. High-Density Plastic: Multimonomer, nonleaching, plastic strip. STRUCTURAL PRECAST CONCRETE 03 41 00-2

2.5 GROUT MATERIALS A. Cement Grout: Portland cement, ASTM C150, Type I, and clean, natural sand, ASTM C404. Mix at ratio of 1 part cement to 2-1/2 parts sand, by volume, with minimum water required for placement and hydration. B. Nonmetallic Shrinkage-Resistant Grout: Pre-mixed, nonmetallic, noncorrosive, nonstaining product containing selected silica sands, portland cement, shrinkage compensating agents, plasticizing and water reducing agents, complying with CRD-C621. 2.6 HOLLOW SLAB UNITS A. Type: Precast prestressed concrete units with open voids running full length of slabs. B. Furnish units which are free of voids or honeycomb, with straight true edges and surfaces. C. Provide "Standard Finish" units unless otherwise indicated. D. Fabrication: Manufacture units of concrete materials which will provide minimum 3500 psi compressive strength at time of initial prestress and 28-day compressive strength of 5000 psi. E. Adequately reinforce slab units to resist transporting and handling stresses. F. Include cast-in weld plates where required for anchorage or lateral bracing to structural steel members. G. Cooperate with other trades for installation of items to be cast-in hollow slab units. Notify Contractor of items not received in ample time so as not to delay work. H. Provide headers of cast-in-place concrete or structural steel shapes for openings larger than one slab width in accordance with hollow slab unit manufacturer's recommendations. PART 3 EXECUTION 3.1 INSTALLATION, GENERAL A. Welding: Perform welding in compliance with AAWS D1.1, including qualification of welders. Protect units from damage by field welding or cutting operations and provide noncombustible shield as required. B. Powder-Actuated Fasteners: Do not use powder-actuated fasteners for surface attachment of accessory items in precast prestressed unit, without prior approval of precast manufacturer. C. Installation Tolerances: Install precast units without exceeding following tolerance limits: 1. Variations from level or elevation: 1/4" in any 20' run; 1/2" in any 40' run; total plus or minus 1/2" at any location. 2. Variation from position in plan: plus or minus 1/2" maximum at any location. 3. Offsets in alignment of adjacent members at any joint: 1/16" in any 10' run; 1/4" maximum. D. Grouting Connections and Joints: After precast concrete units have been placed and secured, grout open spaces at connection and joints with cement grout or nonmetallic nonshrink grout, as follows: STRUCTURAL PRECAST CONCRETE 03 41 00-3

1. Provide forms or other acceptable method to retain grout in place until sufficiently hard to support itself. Fill spaces 100% with grout material and compact until voids are filled and all bonding surfaces coated 100%. 2. Place grout to finish smooth, plumb, and level with adjacent concrete surfaces. Keep grouted joints damp for not less than 24 hours after initial set. Promptly remove excess grout material from exposed surfaces before it hardens. 3.2 QUALITY CONTROL EVALUATIONS A. The Owner may employ a separate testing laboratory to evaluate precast manufacturer's quality control and testing methods. B. The precast manufacturer shall allow Owner's testing facility access to materials storage areas, concrete production equipment, and concrete placement and curing facilities. Cooperate with Owner's testing laboratory and provide samples of materials and concrete mixes as may be requested for additional testing and evaluation. C. Dimensional Tolerances: 1. Units having dimensions smaller or greater than required, and outside specified tolerance limits, will be subject to additional testing as herein specified. 2. Precast units having dimensions greater than required will be rejected if appearance or function of the structure is adversely affected, or if larger dimensions interfere with other construction. Repair, or remove and replace, rejected units as required to meet construction conditions. D. Strength of Units: The strength of precast concrete units will be considered potentially deficient if manufacturing processes fail to comply with any requirements which may affect strength of precast units, including the following conditions: 1. Failure to meet compressive strength tests requirements. 2. Reinforcement, and pretensioning and detensioning of tendons of prestressed concrete, not conforming to specified fabrication requirements. 3. Concrete curing and protection of precast units against extremes in temperature, not as specified. 4. Precast units damaged during handling and erection. E. Testing Precast Units: When there is evidence that strength of precast concrete units does not meet specification requirements, the concrete testing service shall take cores drilled from hardened concrete for compressive strength determination, complying with ASTM C42 or as follows: 1. Take at least 3 representative cores from precast units of suspect strength, from locations directed by Architect. 2. Test cores in an air-dry condition per ACI 318 if concrete will be dry during use of completed structure and in a saturated-surface-dry condition if concrete will be wet during use of completed structure. 3. Strength of concrete for each series of cores will be considered satisfactory if their average compressive strength is at least 85% of 28-day design compressive strength. 4. Test results will be made in writing on same day that tests are made, with copies to Architect, Contractor, and precast manufacturer. Include in test reports the project identification name and number, date, name of precast concrete manufacturer, name of concrete testing service, identification letter, name, and type of member(s) represented by core tests, design compressive strength, compression breaking strength and type of break (corrected for length-diameter ratio), direction of applied load to core with respect to horizontal plan of concrete as placed, and moisture condition of core at time of bearing. F. Patching: Where core test results are satisfactory and precast units are acceptable for use in work, fill cores solid with patching mortar, and finish to match adjacent concrete surfaces. STRUCTURAL PRECAST CONCRETE 03 41 00-4

G. Defective Work: Precast concrete units which do not conform to specified requirements, including strength, tolerances, and finishes shall be replaced with precast concrete units that meet requirements of this Section. Contractor shall also be responsible for cost of corrections to their work affected by or resulting from corrections to precast work. END OF SECTION 03 41 00 STRUCTURAL PRECAST CONCRETE 03 41 00-5