The Point Source. July 2011 Volume 2, Issue 1. Executive message. Rich Fabian. In this issue

Similar documents
Philips Astonish. Key advantages. including improved image quality and

Radionuclide Imaging MII Single Photon Emission Computed Tomography (SPECT)

SPECT Reconstruction & Filtering

Industry Breakthrough

The future of nuclear imaging is clear

Industry Breakthrough

Pitfalls and Remedies of MDCT Scanners as Quantitative Instruments

2010 Philips BrightView XCT SPECT/CT

The shortest distance to diagnosis Philips BrightView SPECT

PET: New Technologies & Applications, Including Oncology

PET/CT Instrumentation Basics

NON-UNIFORM ATTENUATION CORRECTION USING SIMULTANEOUS TRANSMISSION AND EMISSION CONVERGING TOMOGRAPHY

HISTORY. CT Physics with an Emphasis on Application in Thoracic and Cardiac Imaging SUNDAY. Shawn D. Teague, MD

160-slice CT SCANNER / New Standard for the Future

Control and confidence all around. Philips EP cockpit people focused solutions for heart rhythm care

Initial Certification

Maximum Performance, Minimum Space

Simultaneous Reconstruction of the Activity Image and Registration of the CT image in TOF-PET. Ahmadreza Rezaei, Johan Nuyts

Celesteion Time-of-Flight Technology

Philips EasyDiagnost Eleva

Brilliance in everything Philips CT products and services

Changing the Shape of Nuclear Medicine

Quality control of Gamma Camera. By Dr/ Ibrahim Elsayed Saad 242 NMT

ACR Update in Nuclear Medicine Accreditation

Investigation of Multiple Head Registration / Center of Rotation for SPECT Gamma Cameras

Factors Affecting the resolution of SPECT Imaging. h.

Research Support. Dual-Source CT: What is it and How Do I Test it? Cynthia H. McCollough, Ph.D.

Breast Tomosynthesis. Bob Liu, Ph.D. Department of Radiology Massachusetts General Hospital And Harvard Medical School

LSO PET/CT Pico Performance Improvements with Ultra Hi-Rez Option

Slide 1. Slide 2. Slide 3 ACR CT Accreditation. Multi-Slice CT Artifacts and Quality Control. What are the rules or recommendations for CT QC?

... In vivo imaging in Nuclear Medicine. 1957: Anger camera (X;Y) X Y

Ergo TM Imaging System

2/14/2019. Nuclear Medicine Artifacts. Symmetric energy windows

Photomultiplier Tube

SKYLight. Nuclear Camera Platform. Setting new standards. in molecular imaging

New spectral benefi ts, proven low dose

diagnostic examination

New Technology in Nuclear Medicine

Metal Artifact Reduction for Orthopedic Implants (O-MAR)

Iterative Reconstruction in Image Space. Answers for life.

Detector technology in simultaneous spectral imaging

Robert Pagnanelli BSRT(R)(N), CNMT, NCT, FASNC Chief Technologist, Nuclear Imaging Duke University Medical Center. Thursday September 8, 2011

Nuclear Associates , &

How Gamma Camera s Head-Tilts Affect Image Quality of a Nuclear Scintigram?

Simulation and evaluation of a cost-effective high-performance brain PET scanner.

Imaging. The Effects of Collimator Malpositioning in Seven Pinhole Tomography. Neil W. Ratzlaff, Paul H. Brown, Deborah J, Cox, and G.T.

Using GATE to understand performance of a full-torso PET scanner

Performance Characteristics of a State of the Art Preclinical PET/SPECT/CT Scanner

12/21/2016. Siemens Medical Systems Research Agreement Philips Healthcare Research Agreement AAN and ASN Committees

ADVANCED MEDICAL SYSTEMS PTE LTD Singapore Malaysia India Australia

Chiara Secco. PET Performance measurements of the new LSO-Based Whole Body PET/CT. Scanner biograph 16 HI-REZ using the NEMA NU Standard.

Introduction, Review of Signals & Systems, Image Quality Metrics

An Activity in Computed Tomography

NeuViz 16 Computed Tomography. Elevating routine imaging for exceptional results

The image reconstruction influence in relative measurement in SPECT / CT animal

Hideo ONISHI * 1 * 3 Yuki MATSUTAKE * 2 Norikazu MATSUTOMO * 3 Hizuru AMIJIMA * 4. Abstract

Technical Aspects: Image Reconstruction

Maximizing clinical outcomes

CHAPTER 8 GENERIC PERFORMANCE MEASURES

The Architecture of Medical Imaging

Contrast Evaluation for a Dual Head SPECT System with Different Energy Peaking- Drift

Introduction. MIA1 5/14/03 4:37 PM Page 1

1. Patient size AEC. Large Patient High ma. Small Patient Low ma

2D, 3D CT Intervention, and CT Fluoroscopy

Multi-Access Biplane Lab

Automated dose control in multi-slice CT. Nicholas Keat Formerly ImPACT, St George's Hospital, London

Physics, Instrumentation and Data Sciences Council Business Plan FY2019

Clinical Experience Using the Open Bore Multislice CT System Supria (16 slice CT) MEDIX VOL. 61 P.8 P.11

SECTION I - CHAPTER 2 DIGITAL IMAGING PROCESSING CONCEPTS

Aim. Images for this section: Page 2 of 13

An Activity in Computed Tomography

Influence of different iteration levels in fourth generation iterative reconstruction technique on image noise in CT examinations of the neck

PET Detectors. William W. Moses Lawrence Berkeley National Laboratory March 26, 2002

TOPICS: CT Protocol Optimization over the Range of Patient Age & Size and for Different CT Scanner Types: Recommendations & Misconceptions

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

Designing an MR compatible Time of Flight PET Detector Floris Jansen, PhD, Chief Engineer GE Healthcare

Iterative Reconstruction

An innovative detector concept for hybrid 4D-PET/MRI Imaging

Medical Images Analysis and Processing

SIGNA Explorer Lift revives our MR

CZT Technology: Fundamentals and Applications

Appendix I: Artefacts and Trouble-shooting

Redefining Ergonomics

NM Module Section 2 6 th Edition Christian, Ch. 3

GE Healthcare. Senographe 2000D Full-field digital mammography system

Data. microcat +SPECT

HIGH RESOLUTION COMPUTERIZED TOMOGRAPHY SYSTEM USING AN IMAGING PLATE

LaBr 3 :Ce, the latest crystal for nuclear medicine

Grid-like contrast enhancement for bedside chest radiographs acquired without anti-scatter grid

Radionuclide Imaging MII 3073 RADIONUCLIDE IMAGING SYSTEM

PD233: Design of Biomedical Devices and Systems

IBEX TECHNOLOGY APPLIED TO DIGITAL RADIOGRAPHY

Optimized CT metal artifact reduction using the Metal Deletion Technique (MDT)

COMPUTED TOMOGRAPHY 1

Wide-Detector CT for TAVR Planning:

Acceptance Testing of a Digital Breast Tomosynthesis Unit

International Journal of Scientific & Engineering Research, Volume 4, Issue 9, September ISSN

Attrius. product guide. a new perspective for cardiac imaging. contact. product guide. 530 oakmont lane westmont, illinois p

efficiency ddrcompact Series

X-Ray-Based Attenuation Correction for Positron Emission Tomography/Computed Tomography Scanners

Transcription:

The Point Source July 2011 Volume 2, Issue 1 In this issue Executive message from Rich Fabian...1 Handling anxiety...2 Product updates Introducing TruFlight Select PET/CT...3 BrightView XCT Version 2.5...4 Philips Nuclear Medicine case study contests... 5 Technical update Differences between legacy Vantage and CT-AC for cardiac imaging...6 Clinical update How to process Gated Blood Pool SPECT acquisitions in AutoSPECT............ 8 Are you aware? ACR accreditation deadline..9 Executive message It was my pleasure to meet many of you at the Society of Nuclear Medicine in San Antonio a few weeks ago, many of you for the first time. As the new General Manager of Nuclear Medicine for Philips Healthcare, I am excited by all the latest discoveries in our field. At SNM this year, we focused on Imaging 2.0, Philips approach to address the challenges that surfaced by speaking with over 3,000 customers this past year. These challenges include the demand for stronger service and cost reduction, as well as workflow solutions to address patient loads. Hybrid imaging is at the forefront of diagnostic imaging technology today, and new developments in molecular imaging and personalized medicine hold the promise for better patient outcomes and care. I hope you had the opportunity to view our latest innovations and talk with a representative about what we are working on and how Philips can help address your clinical needs. With most of my career focused on marketing and sales, I have a reputation for building strong customer relationships. During my tenure at Philips over the past 10 years, I have served in various marketing and sales leadership roles in Interventional X-ray and Diagnostic X-ray, where I was responsible for over 60% of Philips North American Imaging business. During this time, Philips Interventional X-ray business grew to a dominant market position by listening to our customers and providing tangible solutions to meet their requirements. You can trust that I will bring this same leadership to the Nuclear Medicine business. I look forward to visiting your facility with my teams, getting to know you and your staff and addressing your needs with the latest solutions in Nuclear Medicine. I also hope to see many of you again at upcoming events such as ASTRO and RSNA where Philips will continue to bring you new Imaging 2.0 solutions in clinical collaboration, patient focus, and improved economic value. Emergency use clause... 9 Clinical Education Quick Steps...10 Until then, enjoy your summer. Rich Fabian General Manager, Nuclear Medicine Philips Interactive Flash Drive...11 Test your knowledge...11

Handling anxiety Anxiety is a normal human reaction. Patients often experience anxiety when going to a hospital for a scan. Due to increased anxiety, unknown surroundings and objects in a hospital may appear more negative and threatening then under normal circumstances. Excessive anxiety can make patients less capable of processing information given to them by the staff. Philips Ambient Experience provides a positive environment for patients and healthcare professionals to enhance clinical processes and patient care. Ambient Experience integrates architecture, design and enabling technologies, such as dynamic lighting, sound and imaging, to allow patients to personalize their environment and surround themselves in a relaxing atmosphere. The innovative, people-focused solution allows patients to select room themes, empowering them to be involved in their own care. Specifically for oncology patients Ambient Experience offers the possibility to choose a different theme for each follow up scan to help make each return visit a little different. Look how Ambient Experience can impact your PET/CT suite. Take an interactive 360 tour at http://www.healthcare.philips.com/main/products/ambient_experience/clinical_solutions/demos/freiburg/index.wpd 2

Product updates Introducing TruFlight Select PET/CT Our newest PET/CT scanner makes Time-of-Flight (TOF) technology accessible virtually to everyone. Thanks to Imaging 2.0, a new approach to imaging technology, the TOF technology that was previously available only on premium systems is now available to all. According to a recent NIH study, 1 TOF scans can help improve lung and liver lesion detectability. In the study, the improvement was more pronounced in heavy patients. Philips proprietary TOF technology, Astonish TF, reduces noise in PET imaging and has up to 30% contrast improvement, resulting in exceptional image quality for increased diagnostic confidence and improved small lesion detection. Furthermore, 4D TOF respiratory motion management enhances accuracy through reduced motion artifacts all leading up to improved clinical results. serving a dual purpose. This is just another way Philips has optimized our systems technologically, clinically, and operationally to fit within your individual needs. With up to 5 times higher sensitivity than non-tof scanners, you may be able to reduce radiopharmaceutical dosing in some or all studies. With fast acquisition and reconstruction speeds, TruFlight allows customers to improve workflow, maintain low patient exposure, and create superb images all at an affordable price. Diagnostic CT capabilities also allow the system to be used not only for PET/CT scans, but also for standalone CT scans, thereby The TruFlight Select was launched at this year s Society of Nuclear Medicine annual meeting in San Antonio Texas. 1 El Fakhri, et al. Improvement in Lesion Detection with Whole-Body Oncologic Time-of-Flight PET. J Nucl Med. 2011; 52:347-353. In conventional PET imaging, it s only possible to know that a coincident event has taken place on the line of response, but not the actual location of the event. Time-of-Flight technology uses the actual time difference between the detection of coincident events to more accurately identify the origin of the annihilation. Better identification leads to a quantifiable improvement in image quality. 3

BrightView XCT Version 2.5 Philips Healthcare is pleased to announce the release of BrightView XCT Version 2.5 software with enhanced soft tissue image quality achieved through iterative CT reconstruction for better uniformity and less noise. Philips first introduced this iterative reconstruction software at the 2010 Society of Nuclear Medicine meeting as Full Iterative Technology (FIT) the first hybrid system to provide both iterative SPECT and CT reconstruction capabilities. FIT builds on the value of Astonish SPECT reconstruction, iterative technology that has been proven in practice to improve image quality and reduce dose. This leading technology provides the necessary foundation for advancing future developments in iterative CT reconstruction. Iterative reconstruction can be more sensitive to motion. Therefore iterative reconstruction is not available for 60 second cardiac attenuation correction scans. To achieve the maximum benefit of iterative reconstruction, it is important to use breath holding techniques when acquiring localization images of the chest, abdomen or pelvis. Because some patients are unable to fully comply with breath holding instructions, filtered back projection images are always available. Version 2.5 software is delivered with BrightView XCT systems manufactured in May 2011 and is available as an upgrade to the installed base at no charge. The images below demonstrate uniformity improvements Filtered back projection Iterative reconstruction The images below demonstrate noise reduction Filtered back projection Iterative reconstruction 4

Philips Nuclear Medicine case study contests You are invited to participate in two exciting new case study contests. Philips is pleased to announce case study contests for our BrightView XCT and GEMINI TF Big Bore PET/CT systems. BrightView XCT GEMINI TF Big Bore Case studies for BrightView XCT case study contest must demonstrate how the addition of attenuation correction and localization capabilities add significant value to a SPECT study. Case studies for GEMINI TF Big Bore case study contest must demonstrate the clinical value of Time-of-Flight PET/CT in radiation therapy planning. Case study contest winner will be announced at the European Association of Nuclear Medicine Meeting (October 2011). Case study contest winner will be announced at the ASTRO s 53rd Annual Meeting (October 2011). Case study submissions must be completed between June 1, 2011 September 9, 2011. Case study submissions must be completed between June 1, 2011 September 2, 2011. For complete information on the BrightView XCT case study contest, please contact Jody Garrard, Senior Product Manager, SPECT/CT jody.garrard@philips.com For complete information on the GEMINI TF Big Bore PET/CT case study contest, please contact Raffi Kayayan, PhD, Senior Product Manager, PET/CT raffi.kayayan@philips.com Don t miss out on this exciting opportunity. Contact us today. 5

Technical update Differences between legacy Vantage and CT-AC for cardiac imaging With the introduction of Precedence, and more recently of BrightView XCT, came a new method to perform myocardial perfusion imaging with attenuation correction (AC). Some of our customers who had previous experience using Vantage, our line source based attenuation correction, have noted differences between the attenuation correction they were used to with Vantage and what they re seeing now. This article summarizes the differences between legacy Vantage attenuation correction and CT-based attenuation correction available with BrightView XCT and Precedence. Reconstruction method Vantage acquisitions have historically used the MLEM, or maximum likelihood expectation maximization method, to reconstruct the SPECT data. While MLEM can also be used with CT-based attenuation correction, it is more typical to use OSEM (ordered subset expectation maximization) or Astonish (which is OSEM with resolution recovery) for CT-AC reconstructions. While MLEM and OSEM are both iterative reconstruction methods, OSEM converges more rapidly because there are more updates per iteration. This allows for more sophisticated physics modeling to be incorporated into the reconstruction algorithm while maintaining clinically acceptable reconstruction times. Scatter correction For Vantage with MLEM, scatter is estimated from the measured counts in a fixed scatter energy window located between the 140 kev emission peak for Tc-99m and the 100 kev transmission peak of the Gd-153 line sources. (Scatter correction is only applied for Tc-99m Vantage studies; scatter correction is not used with Tl-201 Vantage studies.) This estimated scatter component is subtracted from the emission projection data prior to reconstruction. appropriate scatter kernel exists on the workstation. (On the EBW NM, scatter kernels currently exist for Tc-99m, Tl-201, I-123, I-131, In-111, Ga-67, and Lu-177.) Resolution recovery For Vantage with MLEM, the projection data is filtered with a sharpening filter based on an average distance between the detector and the heart prior to reconstruction. For CT-AC, Astonish performs resolution recovery using the patient to collimator distance as well as the collimator distance response function. During the acquisition of patient data, the distance from the collimator to the center of rotation is recorded for each projection angle. During the reconstruction process, the amount of blurring is calculated based on this measured distance and a mathematically calculated or measured collimator response function like the example shown below. The counts are spread over multiple pixels during both the forward- and back-projection steps of the iterative reconstruction and the degree of broadening is determined by the distance between the pixel and the collimator and the collimator response function. LEHR resolution vs. distance 12.0 Resolution (mm) 8.0 4.0 For CT-AC with OSEM, scatter correction is performed using the ESSE (Effective Source Scatter Estimation) method. 1 With this approach, the estimate of the scatter is calculated from the emission image estimate, the attenuation map, and a pre-calculated threedimensional scatter kernel that is specific to the emission photon energy and the target energy windows. This modeled scatter component is then added to the current estimate for forwardprojection before it s compared to the measured projection data in the iterative reconstruction process. This scatter correction method can be used with any emission isotope provided that the 0.0 0 5 10 15 20 Distance (cm) Attenuation correction When it comes to the actual attenuation correction piece of the reconstruction, the main difference between Vantage and CT-AC is how a tissue transmission density image is acquired and how the attenuation map is created from this image. For Vantage acquisitions, the attenuation map is reconstructed from the Gd-153 line source 6

transmission projection data. For CT-AC, the attenuation map is generated from the X-ray CT image by converting the Hounsfield values to linear attenuation coefficients using a piecewise linear model. 2 In both cases, the resulting attenuation map is a matrix of linear attenuation coefficients at 100 kev (the emission peak for Gd-153). Furthermore, the application of attenuation correction during the iterative reconstruction process is also the same for Vantage and CT-AC. The attenuation map is used to calculate the amount of attenuation from each point in the object through the body in the forward-projection process. Since the emission energy is typically not 100 kev, the linear attenuation coefficients in the attenuation map are scaled to the appropriate emission photon energy using the relative linear attenuation coefficients for water at the two energies. The bottom line Iterative reconstructions methods are well suited to improve image quality and clinical performance by incorporating internal modeling of the imaging physics in SPECT reconstructions to correct for the major factors degrading image quality. The more accurately the imaging physics can be modeled, the more accurate the reconstruction process can be. For Vantage with MLEM, scatter correction and resolution recovery are achieved by applying relatively rudimentary corrections to the projection data prior to reconstruction. When processing Vantage data with MLEM, the *-EMSCR emission projection data is loaded into AutoSPECT. In this naming convention, EM stands for emission, SC is for scatter correction, and R is resolution recovery; the scatter correction and resolution recovery have already been applied to the projection data before the reconstruction begins. CT-AC with OSEM or Astonish, on the other hand, uses a more sophisticated scatter model and incorporates the scatter correction into the iterative reconstruction process. The resolution recovery provided by Astonish is based on measured distance and a measured collimator response function also incorporated into the iterative reconstruction process. By more accurately modeling the imaging physics in the reconstruction process, CT-AC images reconstructed with Astonish correspond more closely to the true activity distribution as demonstrated by phantom experiments. 1 Frey EC, Tsui BMW. A New Method for Modeling the Spatially-Variant, Object-Dependent Scatter Response Function in SPECT. Nuclear Science Symposium, 1996. Conference Record. IEEE 1996 2:1082 1086. 2 Bai C, Shao L, Da Silva AJ, Zhao Z. A Generalized Model for the Conversion from CT Numbers to Linear Attenuation Coefficient. IEEE Trans. Nucl. Sci. 2003 50:1510 1515. Using Astonish with Vantage data With the introduction of AutoSPECT Pro on EBW NM, some Vantage customers now have the opportunity to use Astonish with their Vantage data from some cameras. Since Astonish needs the measured radial distance for each projection in order to calculate the amount of collimator blur, only those Philips cameras that record this radius information can be used, that is, Forte release 2.0 or later and CardioMD release 2.0 or later. When reconstructing Vantage data with Astonish, it s important to remember that the raw emission data, not the *-EMSCR files used with MLEM, should be loaded into AutoSPECT Pro. Since Astonish applies scatter correction and resolution recovery during the iterative process, uncorrected projection data should be used as the input data. It s also important to note that AutoSPECT Pro on EBW NM has two types of preferences that can be used for attenuation correction; the difference between these two types of preferences is the behavior of the AC Map step. For a Vantage preference, the AC Map step allows the user to set up and execute the reconstruction of the Gd-153 transmission data in order to generate the attenuation map. For a CT-AC preference, the AC Map step allows the user to check (and adjust if necessary) the registration between the SPECT data and the CT data used to generate the attenuation map. In order to reconstruct Vantage data with attenuation correction, you must start with a Vantage preference; you cannot change a CT-AC preference into a Vantage preference or vice versa. When creating preferences for reconstructing CardioMD data with AC using Astonish, there is a characteristic of CardioMD data that one needs to keep in mind; only the primary data set acquired on CardioMD will contain the radius information required by Astonish. This will be the gated data set for a gated acquisition and the EM data set for a non-gated study. So for a gated study, only the gated data and the transmission data (*-TRSC) should be loaded into a Vantage preference. The stress and rest buckets must remain empty because the summed stress and rest data sets will not contain the radial information required by Astonish. However, AutoSPECT Pro will sum the gated data on the fly to facilitate the reconstruction of the summed data with Astonish and AC. For a non-gated study, the raw emission data ( *-EM ) and the transmission data (*-TRSC) should be loaded into a Vantage preference. 7

Clinical update How to process Gated Blood Pool SPECT acquisitions in AutoSPECT Most people are familiar with processing Gated Blood Pool SPECT studies (GBPS) in AutoQUANT/QBS but many are not as familiar with how to reconstruct and reorient these studies in AutoSPECT+ or AutoSPECT Pro. Reconstruction One of the hardest parts about processing a GBPS (Gated Blood Pool SPECT) is the reconstruction. Since GBPS studies are less common than SPECT perfusion studies, most people will reconstruct the data as they are used to, which means only including the left ventricle. Correct reconstruction limit lines include pulmonary conus Incorrect reconstruction limits (LAO and RAO projection) potentially exclude RV and pulmonary Reorientation The lack of familiarity with GBPS can also lead to incorrect reorientation and cropping. Cropping of structures other than the LV can lead to segmentation failures. Correct cropping and reorientation conus (LAO projection) Incorrect reorientation on the vertical long axis Multiple cropping errors (the atria are cropped, image (long axis of the LV should be horizontal) and the pulmonary conus is truncated) Adapted with permission from the Gated Blood Pool SPECT Processing with QBS/BPGS white paper by Serge Van Kriekinge, PhD, dated May 26, 2010. Available upon request. Images courtesy of Serge D. Van Kriekinge, PhD, Cedars-Sinai Medical Center. 8

Are you aware? Are you aware of the new ACR Accreditation deadline and the emergency use clause in the ACR Program Requirements? Are you aware that Philips has a Clinical Education website that provides links to education resources such as courses, product documentation, and Quick Step procedures? Are you aware that you can be kept up to date on the latest Philips products and solutions through the Philips Interactive FlashDrive? If not, read on.... ACR accreditation deadline Currently, the ACR Nuclear Medicine/PET Accreditation Program is a voluntary process. However, effective January 1, 2012, all providers that bill for CT, MRI, breast MRI, nuclear medicine, and PET under part B of the Medicare physician fee schedule must be accredited in order to receive reimbursement for the technical component from Medicare. The ACR website has information on the accreditation process for SPECT and PET, including requirements for accreditation, frequently asked questions, and application forms. http://www.acr.org/accreditation/nuclear.aspx The site also includes a very helpful document that describes the SPECT phantom criteria that can help you evaluate your results before you submit them. Refer to the document ACR Phantom Criteria. http://www.acr.org/accreditation/nuclear/qc_forms.aspx The document states the reconstructed uniformity criteria as: Satisfactory: Faint ring artifacts visualized in the UNIFORMITY and in the complete set of all slices that are not thought to be clinically significant or vice versa. Marginal: Strong artifacts are seen in no more than two slices of the complete set. These criteria apply to all isotopes submitted. The document also includes detailed requirements for contrast and resolution that are isotope specific. If a phantom acquisition receives two Marginal scores, it fails. In order to meet the requirements we recommend that your SPECT system be tuned by your service engineer before you acquire your phantom images and that you use a non-circular orbit for your acquisition. We encourage you to start your application process early to avoid any unplanned delays at the end of the year. Emergency use clause Per the Nuclear Medicine/PET Accreditation Program Requirements document dated 2/28/2011, on the ACR website, a Nuclear Medicine camera does not need to be accredited for an isotope or procedure if it is used only infrequently for that isotope. If less than 5 examinations are performed outside a unit s accreditation status in any 30 day period, or less than 25 examinations in any 12 month period, you need not submit phantom or clinical examples for that isotope for your unit and you will not jeopardize the facility s accreditation status. Refer to page 3 of the Nuclear Medicine/PET Accreditation Program Requirements document dated 2/28/2011 on the ACR website for full details of the Emergency Use Requirement. 9

Clinical Education Quick Steps One of the many resources available on the Clinical Education website is Quick Steps. Quick Steps are abbreviated How to guides for frequently asked acquisition and processing procedures. For example, there are Quick Step guides for: Acquiring SPECT Phantom Data for ACR accreditation Setting up Shortcut keys on EBW NM workstation Acquiring 18F NaF Bone Scan on Gemini TF Big Bore system In order to access the Quick Steps, you must be a registered Philips customer. Clinical Education website registration 1. Launch Internet Explorer and enter www.philips.com/clinicaleducation in the address line. The Philips Clinical Education website will be displayed. 2. Click on the First Time User section to create an account. Your Philips Site Number is your key to gain access to the secure customers only Clinical Education website. 3. Follow the screen instructions for registration. Accessing Quick Step documentation 1. Once you have registered, log in. 2. Under the heading Documentation, click on Hybrid Imaging for PET/CT and Precedence documentation; or click on Nuclear Medicine for SPECT documentation 3. Read the information on Navigating Documentation and then select the product of interest from the links on the left side of the page. 4. The Quick Steps are located under the product Quick Steps and Guides tab. The Philips Customer Care Solutions Center in Atlanta has a full team of technical and clinical associates to support you. Call us at 800-722-9377. 10

Philips Interactive FlashDrive Stay in touch with the latest in Philips nuclear medicine products and services, including image galleries, demo videos, and peer testimonials. The Philips Interactive FlashDrive makes it simple to stay up to date through a convenient and easy-to-use dynamic tool that gives you the choice of updating information whenever you connect to the Internet. Access is simple Contact your Sales Representative to receive this drive. Test your knowledge What is shown in this image? See the answer in our next Point Source newsletter. 11

Philips Healthcare is part of Royal Philips Electronics How to reach us www.philips.com/healthcare healthcare@philips.com Asia +49 7031 463 2254 Europe, Middle East, Africa +49 7031 463 2254 Latin America +55 11 2125 0744 Write to us Is there something you would like to see published in a future edition of The Point Source newsletter? If you have a question or concern that you would like to see answered, please write us at pointsource@philips.com Please note that this method of communication is not a means for service or regular support issues. Not all questions or concerns will be addressed in the newsletter but all will be answered. North America +1 425 487 7000 800 285 5585 (toll free, US only) Please visit www.philips.com/nuclearmedicine 2011 Koninklijke Philips Electronics N.V. All rights are reserved. Philips Healthcare reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. Printed in the USA CLE-11-18437 * JUL 2011