DUAL MODALITY TOMOGRAPHY SYSTEM USING OPTICAL AND ELECTRODYNAMIC SENSORS FOR TOMOGRAPHIC IMAGING SOLID FLOW

Similar documents
Simulation Study of Bubble Detection Using Dual-Mode Electrical Resistance and Ultrasonic Transmission Tomography for Two-Phase Liquid and Gas

MUSTAFA MUSBAH ELMAJRI

Hardware Development of Reflection Mode Ultrasonic Tomography System for Monitoring Flaws on Pipeline

Australian Journal of Basic and Applied Sciences

Charge-Coupled Device Based on Optical Tomography System for monitoring multiphase flow

Ultrasound Processing Circuitry for Ultrasonic Tomography

Design and Modeling of Linear Back Projection (LBP) Algorithm for Field Programmable Gate Array (FPGA)

Jurnal Teknologi SENSITIVITY MAPS RECONSTRUCTION FOR MAGNETIC INDUCTION TOMOGRAPHY MODALITY USING EXPERIMENTAL TECHNIQUE.

Jurnal Teknologi. Full Paper. *Corresponding author

P2000 Electrical Resistance Tomography System. ITS System 2000 Version 5.0 Software. Operating Manual

HIGH RESOLUTION COMPUTERIZED TOMOGRAPHY SYSTEM USING AN IMAGING PLATE

Non Invasive Electromagnetic Quality Control System

SPARSE ARRAY TOMOGRAPHY SYSTEM FOR CORROSION EXTENT MONITORING H. Bian, H. Gao, J. Rose Pennsylvania State University, University Park, PA, USA

PET Detectors. William W. Moses Lawrence Berkeley National Laboratory March 26, 2002

Department of Electrical Engineering and Computer Science

Injection moulding BUDAPEST UNIVERSITY OF TECHNOLOGY AND ECONOMICS FACULTY OF MECHANICAL ENGINEERING DEPARTMENT OF POLYMER ENGINEERING

Niklas Norrby 12/17/2010

Visualization of the Ionization Phenomenon in Porous Materials under Lightning Impulse

SECTION I - CHAPTER 2 DIGITAL IMAGING PROCESSING CONCEPTS

MONITORING the flow velocity of bulk solids moving

Electrical Capacitance Volume Tomography: A Comparison between 12- and 24-Channels Sensor Systems

ANALYSIS OF LINEARLY AND CIRCULARLY POLARIZED MICROSTRIP PATCH ANTENNA ARRAY

ULTRASONIC MEASUREMENT SYSTEM FOR THE ASSESSMENT OF

Compressive Through-focus Imaging

NEURO-FUZZY TECHNIQUE APPLICATION FOR IDENTIFYING FLOW REGIMES OF PARTICLES CONVEYING IN PNEUMATIC PIPELINE

Experiment 19. Microwave Optics 1

Ultrasonic Linear Array Medical Imaging System

Microwave Testing (µt): An Overview. Johann Hinken, FI Test- und Messtechnik GmbH Magdeburg, Germany, July 2016

A NON-INVASIVE AND NON-INTRUSIVE ULTRASONIC TRANSDUCER ARRAY FOR PROCESS TOMOGRAPHY

Development of the LBNL Positron Emission Mammography Camera

Penn State University ESM Ultrasonics R&D Laboratory Joseph L. Rose Research Activities

Optimization of Existing Centroiding Algorithms for Shack Hartmann Sensor

Bias errors in PIV: the pixel locking effect revisited.

STUDY OF TWO-PHASE PIPE FLOW USING THE AXIAL WIRE-MESH SENSOR

A PID Controller Design for an Air Blower System

Active Vibration Isolation of an Unbalanced Machine Tool Spindle

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual

1112. Dimensional evaluation of metal discontinuities by geometrical parameters of their patterns on imaging flaw detector monitor

A Low-Cost Data Acquisition for CMOS-based Optical Tomography System

Optimizing feeding accuracy for your batch or continuous process

Design and construction of double-blumlein HV pulse power supply

Fiberoptic and Waveguide Sensors

Digital Image Processing

Microwave Optics. Department of Physics & Astronomy Texas Christian University, Fort Worth, TX. January 16, 2014

SYLLABUS. 1. Identification of Subject:

Chromatic X-Ray imaging with a fine pitch CdTe sensor coupled to a large area photon counting pixel ASIC

Dual-frequency Characterization of Bending Loss in Hollow Flexible Terahertz Waveguides

SolidFlow 2.0. Solid mass flow measurement. Product Information. SWR engineering Messtechnik GmbH enveatm a trademark of Environnement S.

A NOVEL METHOD OF RATIO CONTROL WITHOUT USING FLOWMETERS

PIV Measurements of Flow immediately above Woven Fabrics

Uncertainty in CT Metrology: Visualizations for Exploration and Analysis of Geometric Tolerances

Jurnal Teknologi OPTICAL TOMOGRAPHY SYSTEM: APPLICATION OF CHARGE COUPLED DEVICE (CCD) FOR SOLID AND TRANSPARENT OBJECTS DETECTION.

Detection and Verification of Missing Components in SMD using AOI Techniques

Design of helical antenna using 4NEC2

REDUCING THE VIBRATIONS OF AN UNBALANCED ROTARY ENGINE BY ACTIVE FORCE CONTROL. M. Mohebbi 1*, M. Hashemi 1

Freeze-fixation of bubbles for micro-ct imaging of liquid aerated food emulsions

A Compact Miniaturized Frequency Selective Surface with Stable Resonant Frequency

DESIGN AND OPERATION OF A WIDE RANGE SEGMENTED GAMMA RAY SCANNING ASSAY INSTRUMENT FOR THE MEASUREMENT OF BOTH LOW AND INTERMEDIATE LEVEL WASTE

Medical Imaging. X-rays, CT/CAT scans, Ultrasound, Magnetic Resonance Imaging

ULTRASONIC GUIDED WAVE FOCUSING BEYOND WELDS IN A PIPELINE

ROBOT VISION. Dr.M.Madhavi, MED, MVSREC

Application of a NaI(TI) scintillation detector in a portable gamma-ray tomography instrumentation for pipeline profiling to detect CUI

Radionuclide Imaging MII Single Photon Emission Computed Tomography (SPECT)

Electromagnetic Band Gap Structures in Antenna Engineering

UWB SHORT RANGE IMAGING

LINEAR INDUCTION ACCELERATOR WITH MAGNETIC STEERING FOR INERTIAL FUSION TARGET INJECTION

Research Article A New Kind of Circular Polarization Leaky-Wave Antenna Based on Substrate Integrated Waveguide

MIRA Purpose MIRA Tomographer MIRA MIRA Principle MIRA MIRA shear waves MIRA

Improving the Collection Efficiency of Raman Scattering

Explain what is meant by a photon and state one of its main properties [2]

Image Smoothening and Sharpening using Frequency Domain Filtering Technique

BATAILG TAIL GAS ANALYZER. Rev. 1.1

SIGNAL PROCESSING FOR ADVANCED CORRELATION ULTRASONIC VELOCITY PROFILER

An Introduction: Radon Transform, X-ray Transform, Inverse Problems

Attenuation length in strip scintillators. Jonathan Button, William McGrew, Y.-W. Lui, D. H. Youngblood

QUANTOF. High-resolution, accurate mass, quantitative time-of-flight MS technology

Electronic supplementary material

Reconstruction Filtering in Industrial gamma-ray CT Application

DC Index Shifted Dual Grating Based Superstructure Fiber Bragg Grating as Multichannel FBG and Multiparameter Sensor

QUANTITATIVE COMPUTERIZED LAMINOGRAPHY. Suzanne Fox Buchele and Hunter Ellinger

The spatial structure of an acoustic wave propagating through a layer with high sound speed gradient

Goal of the project. TPC operation. Raw data. Calibration

Product data sheet Palas Fidas 200 E

A DIGITIZING DEVICE FOR FILMLESS VISUAL DETECTORS. F. Villa Stanford Linear Accelerator Center ABSTRACT

EXPERIMENTAL INVESTIGATION ON LASER BENDING OF METAL SHEETS USING PARABOLIC IRRADIATIONS

RANDY W. ALKIRE, GEROLD ROSENBAUM AND GWYNDAF EVANS

Transmission of Ultrasonic Waves Via Optical Silica Glass Fiber Doped by 7.5% of TiO 2 with the Use of Power Sandwich Transducer

Crosswind Sniper System (CWINS)

Microwave and optical systems Introduction p. 1 Characteristics of waves p. 1 The electromagnetic spectrum p. 3 History and uses of microwaves and

ScanArray Overview. Principle of Operation. Instrument Components

Chapter 18 Optical Elements

Detection of Internal OR External Pits from Inside OR Outside a tube with New Technology (EMIT)

Polarization Experiments Using Jones Calculus

Philip Sperling. Sales Science and New Materials, YXLON International GmbH, Essener Bogen 15, Hamburg, Germany.

Injection moulding BUDAPEST UNIVERSITY OF TECHNOLOGY AND ECONOMICS FACULTY OF MECHANICAL ENGINEERING DEPARTMENT OF POLYMER ENGINEERING

The Decision Aid Leak Notification System for Pigging False Alarm

Historical approach of dust monitoring

Laser Telemetric System (Metrology)

Electromagnetics, Microwave Circuit and Antenna Design for Communications Engineering

Fundamentals of Electromagnetics With Engineering Applications by Stuart M. Wentworth Copyright 2005 by John Wiley & Sons. All rights reserved.

Transcription:

DUAL MODALITY TOMOGRAPHY SYSTEM USING OPTICAL AND ELECTRODYNAMIC SENSORS FOR TOMOGRAPHIC IMAGING SOLID FLOW M. F. Rahmat 1, S. Ibrahim 1, M. M. Elmajri 1, N. F. Mohammed 1, M.D Isa 2 1 Control and Instrumentation Department, Faculty of Electrical Engineering, Universiti Teknologi Malaysia, Skudai, Malaysia, 2 Politeknik Kota Bharu, KM.24 Kok Lanas, 16400 Ketereh,Kota Bharu, Kelantan, Malaysia. E-mails: fuaad@fke.utm.my, salleh@fke.utm.my, Mus_utm@yahoo.com, Balqis_zz@yahoo.com, peppkb@yahoo.com Abstract- Process tomography is a technique to realize flow imaging in a process vessel or pipeline by using the sensor system. This technique involves the use of tomographic imaging methods to manipulate data from sensors in order to collect sufficient information about the flow in the pipeline. The overall aim of this paper is to investigate the benefits of dual modality (optical and electrodynamic) tomography system for the measurement of tomographic images of solids flow. This research will investigate the distribution of conveying plastic beads in a conveying pipe by placing optical and electrodynamic sensors around the pipe without interrupting the flow inside the pipe. Keywords: Dual modality, tomography, solid flow, optical sensors, electrodynamic sensors. I. INTRODUCTION The field of process tomography is growing rapidly. Tomographic imaging offers a unique opportunity to discover the complexities of structure without the need to invade the object [1]. It is an expansion from the early research involving x-ray tomography, which focused on how to obtain 2-D cross-section images of animals, human, and non-living things. The application of process tomography is analogous to the application of medical tomographic scanners for investigating the human body, but applied to an industrial process as there is a widespread need for the direct analysis of the internal characteristics of process 389

M. F. Rahmat, S. Ibrahim, M. M. Elmajri, N. F. Mohammed, M.D Isa, DUAL MODALITY TOMOGRAPHY SYSTEM USING OPTICAL AND ELECTRODYNAMIC SENSORS FOR TOMOGRAPHIC IMAGING SOLID FLOW plants in order to improve the design and operation of equipment [2]. Process tomography can be applied to many types of processes and unit operations, including pipelines, stirred reactors, fluidized beds, mixers, and separators. Depending on the sensing mechanism used, it is non-invasive, inert, and, non-ionizing. It is therefore applicable in the processing of raw materials: in large scale and intermediate chemical production; and in the food biotechnology areas [3]. In tomography, a variety of sensing methods can be used based on very often contradictory factors. While most devices employ a single type of sensor, there are a number of opportunities for multi mode systems using two or more different principles [4]. In principal, there is no single sensing method capable of detecting all suspended solids flow or explore all important flow characteristics. Taking these limitations into account, it is vital to combine the technologies of optical sensors and electrodynamic sensors to produce a single measurement system. The concept of combining both sensing mechanisms provides the opportunity to obtain and compare each other that can be used to improve the accuracy of concentration profiles [5]. II. OPTICAL SENSOR MODELING In optical tomography, the cross section of an object is scanned by a parallel projection (Figure 1). When light passed through the object along the straight line AB in the sensing zone from the light source to the photodiode, light is attenuated as shown in Equation 1. Figure 1: An object, and its projection, shown for angle. 390

(1) where: I o = original intensity of the light source, I = measured intensity, μ = linear attenuation coefficient, and d = thickness of object. The coordinate systems illustrated in Figure 1 are used to describe line integrals and projections. The object is represented by a two-dimensional function f(x, y) and each line integral is represented by the projection angle and a detector position x parameters [6]. The Equation of AB in Figure 1 is shown in Equation 2. where: (2) (3) In addition, this resulted in the line integral By using delta function, this can be rewritten as: For the discrete implementation, Equation 4 can be rewritten as: (5) (6) where: N i =total number of horizontal cell/pixel, M i =total number of vertical cell/pixel. The optical model is based on the length of the optical sensing beam within the conveyer. The voltage of each individual path length sensor increases with increased plastic beads flow rate [7]. It is assumed that the relationship between the number of plastic beads passing through a beam and the corresponding sensor output voltage is linear [8]. For a given uniform flow rate the output voltage from each sensor will be directly proportional to its optical path length. The forward problem provides the theoretical output of each sensor under no-flow and flow conditions when the sensing area is considered two-dimensional. The cross section of the circular pipe is mapped onto a 16 x 16 rectangular arrays of 256 pixels as shown in Figure 2 in order to solve the forward problem. The diameter of the pipe for this project is 80mm, so the dimension of each pixel can calculated as 5mm x 5mm (80mm/16 sensors). The fiber optic (with an outer diameter of 391

M. F. Rahmat, S. Ibrahim, M. M. Elmajri, N. F. Mohammed, M.D Isa, DUAL MODALITY TOMOGRAPHY SYSTEM USING OPTICAL AND ELECTRODYNAMIC SENSORS FOR TOMOGRAPHIC IMAGING SOLID FLOW 2.3mm) was placed at the centre of each pixel. represents the first light transmitter. represents the first optical sensor and Figure 2: A 16 x 16 rectangular array of 256 pixels with optical sensors position. The sensitivity matrix for each sensor is formed by calculating the ratio of the area of the light beam in each pixel to the area of the corresponding pixel. Each pixel is evaluated separately and the contribution from each pixel forms the sensitivity map [9]. The Linear Back Projection Algorithm (LBPA) is chosen in order to develop the concentration profile. It is obtained by combining the projection data from each sensor with its computed sensitivity map. Each sensitivity matrix is multiplied by its corresponding sensor reading to obtain the image reconstruction. III. ELECTRODYNAMIC SENSOR MODELING The induction of voltage on the sensors electrode by charged particles as they flow past the sensors mounted on the conveying wall forms the basic working principle of electrodynamic sensors [10]. It has been established that the magnitude of the charge acquired by solids depends upon the moisture content of the atmosphere, the particle size distribution and the velocity with which the particle moves and/or impinges onto surfaces [11]. The forward 392

problem determines the theoretical output of each electrodynamic sensor when the sensing area is considered two-dimensional and contains a uniformly distributed charged of σ coulombs per square meter [12]. To solve the forward problem, the theoretical output of each sensor due to placing a certain surface charge σ at all the possible locations in the pipe cross section has to be calculated. Similar to the optical system, the pipe cross section for electrodynamic system is mapped onto (16 x 16) rectangular arrays of 256 pixels as shown in Figure 3. Figure 3: A 16 x 16 rectangular array of 256 pixels with electrodynamic sensors position. The center of the electrodynamic pipe is chosen as the origin i.e. (0,0) rectangular coordinate value [13]. The coordinate is determined to calculate the contribution of each pixel to the electrodynamic sensors. The solution to the forward problems needs to define models and calculating the sensitivity map of each sensor. Assume that a uniform surface charge of σ C m -2 is present at each pixel and hence each pixel would induce a certain amount of charge on the array of sensors. All electrodynamic sensors are placed 0.5mm outside the pipe boundary in order to minimize boundary problems. As an example, the general sensitivity equation for first electrodynamic sensor is defined as in Equation 7; (7) 393

M. F. Rahmat, S. Ibrahim, M. M. Elmajri, N. F. Mohammed, M.D Isa, DUAL MODALITY TOMOGRAPHY SYSTEM USING OPTICAL AND ELECTRODYNAMIC SENSORS FOR TOMOGRAPHIC IMAGING SOLID FLOW Where (x, y) is the coordinate of the part of the pixel contributing to the sensor output, r is the distance of the charge from the first electrodynamic sensor, and A is the cross sectional area of the pipe. The linear back projection algorithm is generated when the sensitivity map of each sensor is multiplied by its corresponding sensor reading and the value of similar pixels from all the 16 matrices is summed up to produce the concentration map of 16x16 matrix. IV. MEASUREMENT CONFIGURATION In this project, the projection employs dual modality sensors consisting of optical and electrodynamic position, equally placed outside a pipe with 82 mm outer diameter and 80mm inner diameter. The optical sensor has 32 BPX65 photodiode sensors acting as receivers arranged in orthogonal projection and two halogen bulbs acting as light transmitters. meanwhile, the electrodynamic system has 16 electrodes positioned equidistantly around the periphery of the pipe wall and separated from the optical system at a distance of 10cm. Hence, for the dual modality, the total number of sensors used is 48. The 32 photodiodes are labeled to for the optical sensors, and the 16 electrodes are labeled as to arranged around the circumference of the pipe wall. Suitable signal conditioning circuits process outputs from the sensors before entering a data acquisition system (DAS). The DAS card KPCI-1802HC with 64 channels and 333 k sample per second was used to capture the data. The DAS can only read 64 readings at a time. An outline of the dual modality measurement in tomography system is shown in Figure 4, where plane S O represents optical sensors and plane S E represents electrodes. 394

Figure 4: A block diagram of the dual modality tomography system V. PROCESS RIG Figure 5 shows the main source of data in this project, which is the gravity flow rig. The rig was used to control the flow of material and enable repeated solid concentration and distributions to be monitored. The conveyed material used in this measurement is the plastic beads of mean size 3mm. Several parts formed the flow rig. First is the storage hopper. When the vacuum loader is switched, the plastic beads will move to the hopper before it goes through the measurement systems. Another part is the screw feeder. The mass flow rate of the plastic beads is controlled by adjusting the rotational speed of the screw feeder. The screw feeder was positioned at the bottom of the hopper as shown in the Figure 5. The speed of rotation was set to a suitable value needed by a control unit. The measurement section containing the optical sensors is mounted on a vertical pipe at a distance of 1.20m below the outlet of the screw feeder. In reality, both sets of transducers should be positioned close to each other to reduce the possibility of an image offset when the data sets are combined. On the other hand, the smaller the distance, the better the similarity of signals obtaining from the two planes [14]. In this research, the separation between the optical and electrodynamic sensors is set, as a compromise to 10cm so that each sensor outputs can be compared adequately. The plastic beads were fed from the hopper into the pipe via a suitable speed screw feeder at a controlled rate. 395

M. F. Rahmat, S. Ibrahim, M. M. Elmajri, N. F. Mohammed, M.D Isa, DUAL MODALITY TOMOGRAPHY SYSTEM USING OPTICAL AND ELECTRODYNAMIC SENSORS FOR TOMOGRAPHIC IMAGING SOLID FLOW Figure 5: gravity flow rig diagram VI. RESULTS Concentration profiles of the plastic beads flowing in the gravity flow rig are produced using Linear Back Projection(LBP) algorithm for optical and electrodynamic tomographic systems. Figures 6 (a) and (b) show the concentration profile for optical sensor for half flow, whereas Figures 7 (a) and (b) show the concentration profile for electrodynamic sensor for the same flow. The concentration profile in Figures 6 (a) and (b) clearly show that half of the pipe has much lower concentration compared to the rest of the pipe. Meanwhile Figures 7 (a) and (b) show that the area of flowing plastic beads has higher voltage when the flow occurs compared to the blocking area. Sensors sixth, S E5 to twelfth, S E11 have more concentration compared to other sensors. Lower concentration values are observed at the center of the profile. Moreover, several values are observed at the peripheral of the pipe, which means there is a high concentration of plastic beads at those pixels. 396

Figure 6: Concentration profile for optical sensor for a half flow condition (a) Two dimension (b) Three dimension. Figure7: Concentration profile for electrodynamic sensor for half flow condition (a) Two dimension (b) Three dimension DISCUSSION AND CONCLUSION A dual modality tomographic system is described for the concentration profile of the plastic beads for optical and electrodynamic tomographic images with the same pattern flow using the same material. The concentration profile for electrodynamic shows that the response of the material flowing near the pipe wall is better compared to the middle of the pipe. In other words, the detection of the material near the sensing zone is higher compared to the area far away to sensors. The electrodynamic is insensitive to permittivity changes at the center of the sensor, which is located far from the electrodes. On the other hand, the images produced by the optical measurement system are shown to be uniform when detecting the materials flow in the pipeline. It is most sensitive at the center of the pipe. Therefore, in many cases, the 397

M. F. Rahmat, S. Ibrahim, M. M. Elmajri, N. F. Mohammed, M.D Isa, DUAL MODALITY TOMOGRAPHY SYSTEM USING OPTICAL AND ELECTRODYNAMIC SENSORS FOR TOMOGRAPHIC IMAGING SOLID FLOW application of only one tomographic modality is not sufficient to explore all important flow characteristics. Further work should be carried out to fuse these images so that an accurate representation of the actual concentration profile can be obtained. REFERENCES [1] Beck, M. S. and Wiliams, R. A, "Process tomography: a European innovation and its aplications", Meas. Sci. Technol. Vol(7): 215 224, 1996. [2] Abdul Rahim, R., Chiam, K.T., Jayasuman, P, "Embedded system based optical tomography: the concentration profile", Sensor Review Journal, Vol.29, No.1, pp. 54-62, 2009. [3] Xu. H., Baidoo, K., Gunn, A.J., Boswell, A.C., Milenic, D.E., Choyke, P.L. and Brechbiel, M.W, "Design, Synthesis and Characterization of a Dual Modality Positron Emission Tomography and Fluorescence Imaging Agent for Monoclonal Antibody Tumor - Targeted Imaging", Journal Medical Chemical, Vol. 50, 4759-476, 2007. [4] Abdul Rahim, R., Green R. G., Horbury, N., Dickin, F. J., Naylor, B. D., and Pridmore, T. P, "Further development of a tomographic imaging system using optical fibres for pneumatic conveyors", Meas. Sci. Technol. Vol(7): 419-422, 1993. [5] T. Dyakowski, G. A. Johansen, D. Sankowski, V. Mosorov, J. Wlodarczky, "A dual modality tomography system for imaging gas/solids flow", Proceeding 4th World Congress on Industrial Process Tomography, 2005. [6] Kak, A. C. and Slaney, M. C. "Principle of Computerized Tomography Imaging", New York: IEEE Press. The Institute of Electrical and Electronics Engineers, Inc. 1999. [7] Ibrahim, Sallehuddin and Green, Robert Garnett, "Optical tomography for imaging process flow", Proc. MSTC, Melaka, Malaysia, pp. 149-155, October 8th 10th, 2001 [8] Sallehuddin bin Ibrahim, "Measurement of Gas Bubbles in a Vertical Water Column using Optical Tomography", Doctor Philosophy, Sheffield Hallam University, 2000. [9] Ruzairi bin Abdul Rahim, "A Tomography Imaging System for Pneumatic Conveyors using Optical Fibers". Doctor Philosophy, Sheffield Hallam University, 1996. [10] M. F. Rahmat and N.S. Kamaruddin, "An electrodynamic sensor for electrostatic charge measurement", International Journal on Smart Sensing and Intelligent Systems, vol. 2, no. 2, june 2009 398

[11] Xu, C., Zhang, J., Yang, D., Zhou, B., Tang, G., Wang, S. "Dense-phase pneumatically conveyed coal particle velocity measurement using electrostatic probes and cross correlation algorithm", pp012004, 2009. [12] Green, R. G., Rahmat, M. F., Dutton, K., Evans, K., Goude, A. and Henry, M., "Velocity and Mass Flow Rate Profile of Dry Powders in a Gravity Drop Conveyer using an Electrodynamic Tomography System", Meas. Sci. Technol., Vol. 8, 429-436, 1997. [13] M. F. Rahmat, N. S. Kamaruddin, and M. D. Isa, "Flow Regime Identification In Pneumatic Conveyor Using Electrodynamic Transducer and Fuzzy Logic Method", International Journal on Smart Sensing and Intelligent Systems, Vol. 2, No. 3, September 2009 [14] Deng, X., Dong, F., Xu, L. J., Liu, X. P. and Xu, L. A., "The Design of a Dual-Plane ERT System for Cross Correlation Measurement of Bubbly Gas/Liquid Pipe Flow". Measurement Science Technology., Vol. 12, 1024-1031, 2001. 399