An Activity in Computed Tomography

Similar documents
An Activity in Computed Tomography

PHOTOGATE 0662I WITH PULLEY ATTACHMENT User s Guide

Physics 4C Chabot College Scott Hildreth

Single-Slit Diffraction. = m, (Eq. 1)

C a t p h a n. T h e P h a n t o m L a b o r a t o r y. Ordering Information

COMPUTED TOMOGRAPHY 1

Single Slit Diffraction

Medical Imaging. X-rays, CT/CAT scans, Ultrasound, Magnetic Resonance Imaging

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

Radionuclide Imaging MII Single Photon Emission Computed Tomography (SPECT)

AQA P3 Topic 1. Medical applications of Physics

Distortion Correction in LODOX StatScan X-Ray Images

Fig. 1

1 Diffraction of Microwaves

Name: Date: Block: Light Unit Study Guide Matching Match the correct definition to each term. 1. Waves

PD233: Design of Biomedical Devices and Systems

Lab 12 Microwave Optics.

X rays X-ray properties Denser material = more absorption = looks lighter on the x-ray photo X-rays CT Scans circle cross-sectional images Tumours

Laboratory 1: Motion in One Dimension

Computer Tools for Data Acquisition

X-RAY COMPUTED TOMOGRAPHY

Nuclear Associates , , CT Head and Body Dose Phantom

I look forward to seeing you on August 24!!

Related topics Beam hardening, cupping effect, Beam hardening correction, metal artefacts, photon starvation

Experiment 1: Fraunhofer Diffraction of Light by a Single Slit

Introduction of a Single Chip TLD System for Patient Dosimetry

Explain what is meant by a photon and state one of its main properties [2]

Experiment P55: Light Intensity vs. Position (Light Sensor, Motion Sensor)

Spectroscopy Lab 2. Reading Your text books. Look under spectra, spectrometer, diffraction.

Longitudinal No, Mechanical wave ~340 m/s (in air) 1,100 feet per second More elastic/denser medium = Greater speed of sound

Principles of CT scan

National 3 Physics Waves and Radiation. 1. Wave Properties

AgilEye Manual Version 2.0 February 28, 2007

Modern Physics Laboratory MP4 Photoelectric Effect

SECTION I - CHAPTER 2 DIGITAL IMAGING PROCESSING CONCEPTS

KULLIYYAH OF ENGINEERING

COMPUTATIONAL IMAGING. Berthold K.P. Horn

Test procedures Page: 1 of 5

Kit for building your own THz Time-Domain Spectrometer

SPECTRAL SCANNER. Recycling

LIGHT BOX & OPTICAL SET CAT NO. PH0615

Part 1: Standing Waves - Measuring Wavelengths

LECTURE 20 ELECTROMAGNETIC WAVES. Instructor: Kazumi Tolich

Collecting Live Data in Fathom NCTM 2013

The physics of ultrasound. Dr Graeme Taylor Guy s & St Thomas NHS Trust

Alignment of the camera

CHAPTER 2 COMMISSIONING OF KILO-VOLTAGE CONE BEAM COMPUTED TOMOGRAPHY FOR IMAGE-GUIDED RADIOTHERAPY

Electromagnetic Waves

Exercise 4-1. Chaff Clouds EXERCISE OBJECTIVE

used to diagnose and treat medical conditions. State the precautions necessary when X ray machines and CT scanners are used.

Activity P35: Light Intensity in Double-Slit and Single-Slit Diffraction Patterns (Light Sensor, Rotary Motion Sensor)

Instruction manual for T3DS software. Tool for THz Time-Domain Spectroscopy. Release 4.0

TSBB09 Image Sensors 2018-HT2. Image Formation Part 1

INTRODUCTION. 5. Electromagnetic Waves

Shape sensing for computer aided below-knee prosthetic socket design

Fast Optical Form Measurements of Rough Cylindrical and Conical Surfaces in Diesel Fuel Injection Components

BLACK BODY LIGHT SOURCE FOR THE OS-8539 EDUCATIONAL SPECTROPHOTOMETER

X-rays in medical diagnostics

QC Testing for Computed Tomography (CT) Scanner

Electronic Brachytherapy Sources. Thomas W. Rusch

HISTORY. CT Physics with an Emphasis on Application in Thoracic and Cardiac Imaging SUNDAY. Shawn D. Teague, MD

3D Diode Array Commissioning: Building Confidence in 3D QA Technology

TEP Optimization of the CT scan quality. Related topics Number of projections, stop angle, exposure time, image statistics, binning

T h e P h a n t o m L a b o r a t o r y

CyberKnife Iris Beam QA using Fluence Divergence

Section Electromagnetic Waves and the Electromagnetic Spectrum

Educational Spectrophotometer Accessory Kit and System OS-8537 and OS-8539

Unit thickness. Unit area. σ = NΔX = ΔI / I 0

Y11-DR Digital Radiography (DR) Image Quality

Concepts of Physics Lab 1: Motion

Visibility of Detail

Technical Notes. Integrating Sphere Measurement Part II: Calibration. Introduction. Calibration

- Water resistant. - Large size.

GafChromic QuiCk Phantom with EBT3P/3+P Film and FilmQA Pro for Radiation Therapy Dosimetry Applications

4.6 Waves Waves in air, fluids and solids Transverse and longitudinal waves

ENSC 470/894 Lab 3 Version 6.0 (Nov. 19, 2015)

EXPRIMENT 3 COUPLING FIBERS TO SEMICONDUCTOR SOURCES

Learning Intentions: P3 Revision. Basically everything in the unit of Physics 3

RENISHAW INVIA RAMAN SPECTROMETER

IBEX MATERIALS DETECTION TECHNOLOGY

EDUCATIONAL SPECTROPHOTOMETER ACCESSORY KIT AND EDUCATIONAL SPECTROPHOTOMETER SYSTEM

Lab in a Box Microwave Interferometer

Standard Operating Procedure

MC SIMULATION OF SCATTER INTENSITIES IN A CONE-BEAM CT SYSTEM EMPLOYING A 450 kv X-RAY TUBE

Fire CR Calibration Guide

The operation manual of spotlight 300 IR microscope

Leica DMi8A Quick Guide

12 Projectile Motion 12 - Page 1 of 9. Projectile Motion

Projectile Launcher (Order Code VPL)

TOPICS: CT Protocol Optimization over the Range of Patient Age & Size and for Different CT Scanner Types: Recommendations & Misconceptions

Horiba LabRAM ARAMIS Raman Spectrometer Revision /28/2016 Page 1 of 11. Horiba Jobin-Yvon LabRAM Aramis - Raman Spectrometer

Quality control of Gamma Camera. By Dr/ Ibrahim Elsayed Saad 242 NMT

Point Spread Function. Confocal Laser Scanning Microscopy. Confocal Aperture. Optical aberrations. Alternative Scanning Microscopy

4.6.1 Waves in air, fluids and solids Transverse and longitudinal waves Properties of waves

Uses of Electromagnetic Waves

Information & Instructions

Real-Time Scanning Goniometric Radiometer for Rapid Characterization of Laser Diodes and VCSELs

Experiment A2 Galileo s Inclined Plane Procedure

Renishaw InVia Raman microscope

Magnetic Fields. Introduction. Ryerson University - PCS 130

Transcription:

Pre-lab Discussion An Activity in Computed Tomography X-rays X-rays are high energy electromagnetic radiation with wavelengths smaller than those in the visible spectrum (0.01-10nm and 4000-800nm respectively). As X-rays pass through a person some of the X-rays will be absorbed, meaning fewer X- rays leave the body than entered it. This is called attenuation and is larger (fewer exiting X-rays) for denser material. Bone, for example, attenuates X-rays more than muscle since bone is denser. Images produced with X-rays are like shadows, showing where the X-ray radiation passed through the body and where it was absorbed. Dark regions on an X-ray image correspond to tissue with smaller attenuation coefficients and lighter regions with denser tissue like bone (see Fig. 1.1). The main drawback to X-ray imaging is that intense or prolonged exposure leads to serious health problems such as cancer and radiation burns. High energy X-rays can change the molecular structure of tissue, sometimes causing a person s DNA to mutate faster than normal. Because of this drawback, the goal of all forms of X- ray imaging is to acquire the best possible image while submitting the patient to the lowest possible dose of radiation. Computed Tomography One of the limitations of planar images like chest X-rays are that they are a two dimensional representation of a three dimensional object. This limits the amount of information that can be discerned. For example, an X-ray of a box, in which a cone and sphere are placed, may look something like Fig. 1.2 (a). From this we may be able to say what kind of objects they are but not their relative locations. For example, is the sphere in front of the cone or is the cone in front of the sphere? But if we rotate the X-ray 90 o relative to the box we may get an image like Fig. 1.2 (b). This is the basic idea behind Computed Tomography where multiple X-rays scans from different angles are put together to form an image. Of course this also means that the radiation dose for a CT scan is larger than for a regular single X-ray scan. (a) (b) Fig. 1.1 Cranial CT scan. The white region is the skull and the darker regions are soft tissue. Source: Computed Tomography: From Photon Statistics to Modern Cone-Beam CT Fig. 1.2 Projections of a sphere and a cone. (a) a single image imparts a limited amount of information (b) another image at a different angle can reveal additional information

Back Projection Back projection is one of the most common methods for reconstructing an image. The images in Fig. 1.2 are called projections. In a CT scanner, an X-ray source rotates around an object producing area projection data at each angle. That data is spread back onto an image of the area, which is divided into pixels. Pixels are the individual units of the reconstruction. Each pixel has a certain value attached to it which corresponds to the attenuation at that point (Fig. 1.3). When put together, all the pixels reveal an image. As more and more X-ray scans are taken and data is back projected, an image of the area starts to emerge similar to what is shown in Fig. 1.4. It is important to note that because projection data are collected from multiple angles, CT imaging results in a higher dose of radiation than planar imaging. Today patients receiving a CT scan are exposed to the equivalent of 30 to 442 chest x-rays per scan The near IR-light used in a photogate has a larger wavelength (880nm) and lower energy than X- rays. Infrared light is quickly attenuated by water inside the human body and is not suitable for medical imaging of deep tissue. However, it is able to pass through material with low attenuation coefficients like the light filter used in this experiment. The projection data recorded by the photogate will be a digital signal of 0 (unblocked) and 1(blocked), rather than the continuous signal of an X-ray based CT scanner (Fig. 1.3). Photogate scans Back Projection Photogate scans Fig. 1.3 Projection data is smeared back onto a reconstruction of the scanned area. Pixels of higher values correspond to the position of the object. The projection data are the 0s and 1s to the right and bottom of the first grid and represent the unblocked and blocked states of the photogate respectively. 2

Geometry Once the Photogate is blocked and we have projection data to work with, the computer spreads that data back onto the reconstruction graph. To do this we need to mathematically describe each scan. This requires us to find an equation for the imaginary line from the light source of the photogate to the detector, relative to the scanned area. The only data we have as inputs are (1) the distance between the rotational axis and the origin Focus-Center-Distance (FCD) (see Fig. 2.2), (2) the angle between the rotational axis and the negative x-axis,θ, and (3) the angle between the FCD and the scanning line,φ, (Fig. 1.4). Rotational Axis y φ IR Source Scanning line Focus-Center-Distance (FCD) IR Detector θ x Fig. 1.4 Geometry of the CT scanner, the Scanning line represents the line connecting the light source and detector of the photogate We can use geometry and trigonometry to find the equation of the scanning line. All we need are some trig identities (SOH CAH TOA) and the formula for a line (y=mx+b). There are multiple formulas we use to describe specific scanner geometries. Which formula we choose for the scanning line changes depending on the values ofθ, φ and the FCD. Each possibility is programmed into LabVIEW, which selects the appropriate formula based on the inputs. 3

Computed Tomography Experiment Guide Introduction In this activity students will be given a mystery box, in which 1 to 3 cylinders were placed by the instructor before class. This enclosure should be sealed so that students don t know the locations of the cylinders. The students will use a photogate, rotary motion sensor and a LabVIEW program to make an image of the contents of the enclosure. Using that image, they will determine the position and dimensions of the cylinders inside. Objectives After completing this lab, students should be able to: Describe the basics of how Computed Tomography makes an image through back projection. Demonstrate a practical application of SOH CAH TOA and the line equation y=mx+b. Understand terms important to CT such as image artifacts and windowing Find the location and diameters of objects inside an opaque mystery box Equipment Vernier photogate (with rod), rotary motion sensor (with pulley) and LabPro Clamp to attach the photogate to the rotary sensor Rotating platform and base with angular scale Angular indicator Rotary sensor stand Congo Blue #181 light filter enclosure Cylinders of various diameters (~0.5 2 cm) Fig 2.1 Apparatus setup 4

LabPro/Computer Setup 1) Make sure the LabPro is connected to a USB port 2) Plug the photogate into the Dig/Sonic 1 jack and the rotary motion sensor into the Dig/Sonic 2 jack. Apparatus Setup 1) Assemble the apparatus as shown in Fig. 2.1. Make sure that the rotation sensor stand and the rotation table stand are aligned and that the angular indicator points straight down the x-axis. 2) Lower the rotary sensor so that the degree indicator is just resting on the rotating platform. This will help stabilize platform. (Using a heavy rotary sensor stand reduces the chances of moving the rotary sensor during the experiment.) 3) Adjust the apparatus as needed so the photogate is free to pass over the mystery box. 4) Measure the Focus-Center-Distance (the distance in cm between the shaft of the rotation sensor to the center of the platform). Record it in the space below. FCD = (cm) FCD Fig. 2.2 The Focus-Center-Distance (FCD) is the distance between the shaft of the rotary sensor and the center of the rotating platform. 5

Apparatus Calibration Open the program Computed Tomography and click on Manual Scanner. Follow the on-screen instructions. It is important that the two stands are aligned and that the angular indicator points straight down the x- axis. If they are not correctly positioned, the resulting image will be distorted. To verify that the apparatus is positioned correctly, perform the following test. 1) Place a cylindrical object at the center of the grid on the platform 2) Enter the FCD you recorded in the Apparatus Setup section. 3) Making sure the photogate is not blocked, click on BEGIN SCAN. Slowly move the photogate over the object placed at the origin. The image in the reconstruction graph should be symmetric about the x-axis (Fig. 2.3). If the image is not symmetric: a. Realign the rotary sensor stand and the rotating platform b. Re-zero the rotating sensor c. Repeat this procedure until the image is symmetric While performing this test, take note of the scanning speed needed to produce a good image. Does a slower or faster scan rate produce better data? (a) Bad Calibration (b) Good Calibration Fig 2.3 - Two scans of the same cylinder positioned at the origin. (a) The image is not symmetric about the x-axis. Make sure the rotating platform base and the base holding the rotary sensor are aligned and re-zero the rotary sensor. (b) The two bases are properly aligned and the rotary sensor was correctly zeroed; therefore the scan of the cylinder is symmetric about the x-axis. 6

Data Collection Using a Cylinder at the Origin 1) With the cylinder still at the origin, do multiple scans at differing speeds. Which speed do you think will result in a higher quality scan? Could slower scan times be dangerous in medical CT? Why? 2) Change the pixel count by incrementing the Pixel/cm control and clicking SET PIXEL COUNT and scan the cylinder (increment Pixel/cm by at least 10 initially). How do image quality and scan time change with an increased pixel count? Why? Using the Mystery Box 1) Place the enclosure on the grid, align the photogate with the x-axis and rotate the platform 360 o to make sure that the enclosure and the photogate won t touch during the scan. 2) With the photogate at the starting position, click BEGIN SCAN. Slowly move the photogate over the enclosure. A single pass should take 15 to 20 seconds. 3) Once the photogate has made a complete pass, rotate the platform, enter the new θ and scan the enclosure again. Repeat for desired number of θ angles. For your first scan try scanning in 20 o increments. An image artifact is a false representation of the actual scanned area. Does your final image show any artifacts? What caused the artifacts? 7

4) Adjust the Window slider to highlight important data. Describe why the image is changing. Describe how changing the Window improved the image. 5) Right click on the cursor toolbar and click on Create Cursor>Free. Using the cursor(s) determine the position and diameter of each object. To display a cursor, right click on the cursor area below the graph and go to Create Cursor>Free. Click and drag the intersection of the two lines of the cursor to the center of the object. The corresponding grid markers on the left and bottom of the scan area indicate the location. Do the objects in your scan look circular? If not, what could be done to improve your image? 8