SYNGUIDER USER'S MANUAL

Similar documents
A Stony Brook Student s Guide to Using CCDSoft By Stephanie Zajac Last Updated: 3 February 2012

Orion StarShoot Solitaire AutoGuider #52074

Astroimaging Setup and Operation. S. Douglas Holland

Olivier Thizy François Cochard

Using the USB2.0 camera and guider interface

Multi-Purpose Computerized Mount. Instruction Manual

User Manual. 1. Item Checklist. 2. Quick Start Guide. - version 1.0 -

User Manual - version 1.0 -

Handbook for the Starlight Xpress AO unit Issue 1 21/8/2005 Handbook for the Starlight Xpress SXV-AO unit

TVGuider astronomical telescope autoguider

Orion StarShoot Autoguider PRO

Gemini G53F German Equatorial Mount

Gemini G53F German Equatorial Mount

Orion StarShoot AutoGuider

Reference and User Manual May, 2015 revision - 3

NexImage Burst USER S MANUAL Model # 95518, # ENGLISH

QUANTUM Qflash T2 / X2 OPERATING INSTRUCTIONS

NexImage USER S MANUAL. Model # 93708, # # 95518, # ENGLISH

RPS-9000 Programming Software for the TYT TH-9000

Introduction. Imaging and Processing Overview -Equipment and Software

USING THE 2 TELETUBE XLS TM & TELECAT XLS TM ADJUSTABLE SIGHT TUBE

Digital Director Troubleshooting

ATP-5189 Programming Software for the Anytone AT-5189

Your Complete Astro Photography Solution

Model ST-4 Star Tracker Imaging Camera. Operating Manual

AF Area Mode. Face Priority

ATP-588 Programming Software for the Anytone AT-588

Handbook for the SX SuperStar high resolution guide camera

AgilEye Manual Version 2.0 February 28, 2007

Digital Matrix User s Guide

INSTRUCTION MANUAL # Providing Exceptional Consumer Optical Products Since Customer Support (800)

QUANTUM Qflash MODEL T OPERATING INSTRUCTIONS

Observational Astronomy ASTR 2401 Texas Tech University OBSERVING MANUAL

AG Optical Systems. Newtonian Astrograph Manual Version AG Optical Systems

The ideal K-12 science microscope solution. User Guide. for use with the Nova5000

ADMS-847 Programming Software for the Yaesu FT-847

400GTO Lubrication Guide

Astrophotography. An intro to night sky photography

CCDTRACK. Tracking Software for the ST-4. Table of Contents. SBIG - Santa Barbara Instrument Group

25 Questions. All are multiple choice questions. 4 will require an additional written response explaining your answer.

Telescopen > Catadioptrisch Spiegel /lens > Celestron > Celestron CGX-L > Celestron CGX-L 9,25 EdgeHD. Robtics

Telescopen > Catadioptrisch Spiegel /lens > Celestron > Celestron CGX-L > Celestron CGX-L 11 EdgeHD. Robtics

INSTRUCTION MANUAL. AZGTi Mount. Copyright Sky-Watcher

Installation Guide. Suitable for: OEM Integration OEM Installation Retro Fit Installation

OTHER RECORDING FUNCTIONS

Nova Full-Screen Calibration System

Luna 0.4B user s manual.

FOCUS, EXPOSURE (& METERING) BVCC May 2018

2DNR 3-Axis Gimbal Vari-focal Vandal Resistant Dome Camera

OTHER RECORDING FUNCTIONS

BASIC IMAGE RECORDING

CobraCam USB III Portable Inspection Camera with USB Interface Instruction Manual

1.3. Before loading the holder into the TEM, make sure the X tilt is set to zero and the goniometer locked in place (this will make loading easier).

ENSC 470/894 Lab 1 V1.4 (Oct )

Introducing Celestron s EdgeHD Optical System

Installation Instructions FW8S-STXL / FW8G-STXL Filter Wheel

Legacy Woodworking Machinery a division of Phantom Engineering. The Legacy CNC. Assembly Manual

DSLR FOCUS MODES. Single/ One shot Area Continuous/ AI Servo Manual

1200 DPS Programmable Digital Powder System

Digital Microscope. User Manual

Feasibility and Design for the Simplex Electronic Telescope. Brian Dodson

Studuino Icon Programming Environment Guide

P20 Zoom Flash Zoom Flash P20 P20 Zoomblitz Flash con zoom P20 Flash externo P20 Flash Zoom P20

ImagesPlus Basic Interface Operation

SBIG ASTRONOMICAL INSTRUMENTS

CCD User s Guide SBIG ST7E CCD camera and Macintosh ibook control computer with Meade flip mirror assembly mounted on LX200

ENSC 470/894 Lab 1 V2.0 (Sept )

Bruker Dimension Icon AFM Quick User s Guide

AT-5888UV Programming Software for the AnyTone AT-5888UV

2016 Motorized Shades Basic Programming

Bruker Dimension Icon AFM Quick User s Guide

Eric B. Burgh University of Wisconsin. 1. Scope

XI. Rotary Attachment Setups

Imaging for the Everyone: A review of the Meade DeepSkyImager By Stephen P. Hamilton

Handbook for the Starlight Xpress AOLF unit Issue 3 17/8/2015. Handbook for the Starlight Xpress SXV-AOLF unit (version 2)

Service Manual for XLE/XLT Series Laser Engravers

2.2 Laser Etching with BoXZY. This manual will get you started laser etching with BoXZY. Written By: BoXZY boxzy.dozuki.

262 The Astrophotography Manual. Templates

Hartmann Sensor Manual

1.2. Make sure the viewing screen is covered (exposure to liquid N 2 may cause it to crack).

These aren t just cameras

User s Manual. For correct usage please read these instructions carefully and keeps in a safe place for future reference!

Getting started with Digital Astrophotography - Part II Rodger King - Dec 2016

MEASUREMENT CAMERA USER GUIDE

QHY367C. User s Manual Rev. 1.3

How to Calibrate a CNC Machine's Positioning System

inphoto ID Canon and Olympus camera control software Automatic ID photography User Guide

DE1103 PLL FM STEREO/SW.MW.LW DUAL CONVERSION SYNTHESIZED WORLD RECEIVER OPERATION MANUAL

Shepherd 210A Fingerprint Door Lock Installation Manual V1.1

rino 600 series quick start manual

UNCOMPLICATED ASTROPHOTOGRAPHY. Bill Weaver

EPIC and EPIC 100 User Guide

West Bond Model 7476E-79 Wedge Wire Bonder STANDAR OPERATING PROCEDURE Version: 1.0 March 2014

Exercise 6. Range and Angle Tracking Performance (Radar-Dependent Errors) EXERCISE OBJECTIVE

ALM473 DUAL MONO \ STEREO AUDIO LEVEL MASTER OPERATION MANUAL IB

FLAMINGOS at the KPNO 2.1-m

Rotary Fixture M/V/X CLASS LASER SYSTEMS. Installation and Operation Instructions

Starlight Xpress Ltd. SXV-M7 CCD camera user manual

Dozuki. Written By: Dozuki System. Guide to calibrating the Haas wireless intuitive probing system. How to Calibrate WIPS

USB Line Camera 8M. Coptonix GmbH

Transcription:

SYNGUIDER USER'S MANUAL GETTING STARTED PREPARING THE SYNGUIDER BASIC OPERATIONS OPERATION UNDER THE NIGHT SKY SPECIFICATIONS 1 3 4 9 15 060613V1 Thank you for choosing the SynGuider. The SynGuider can guide an equatorial mount without the help of a computer. It will improve the image quality and help you achieve pin-point stars in you long-exposure photography.

1 ABOUT THE SYNGUIDER II PACKAGE Please take some time to check your new SynGuider II package and become familiar with each component. Some parts are installed on the SynGuider main body out of the box. You will need to uninstall them before using the SynGuider. 1.25 Extension Barrel M42-to1.25 Adapter Par Focal Ring SynGuider s Main Body Hand Pad Guiding Cable Battery Case

SYNGUIDER II MAIN BODY 2 FRONT VIEW REAR VIEW A G B C D E F A. M42 thread B. Image Sensor C. Power Jack D. USB Port E. Autoguider Port F. Hand Pad Port G. LCD Screen

3 PREPARING THE SYNGUIDER PREPARING THE POWER SUPPLY User can use four D type 1.5V batteries (not included) with the battery case as the power supply for SynGuider. To use a different power supply, it must match the following requirements: DC 4.5V~14V output voltage, a +5V power supply is recommended. 150mA and up output current 2.1mm power plug, central positive PREPARING THE IMAGING SYSTEM The basic requirements for the equipment to use with SynGuider are: Telescope Mount: Equatorial mount, or Alt-Az mount with a wedge, with a dual-axis motor drive attached. The motor drive must be able to accept ST-4 compatible autoguiding signals. Connecting Cable: You may use the supplied dual RJ-12 plug autoguiding cable if the pin configuration of your motor drive is the same as the diagram shown on the right. An alternative cable is required if the pin configuration of your motor drive is different. 654321 1= NC 2= Ground 3= +RA (left) 4= +DEC (up) 5= -DEC (down) 6= -RA (right) Guide Scope: An additional telescope with a M42-0.75 thread or a 1.25 eyepiece holder is required as guide scope. Larger aperture, at least 80mm, helps reduce the exposure time of the SynGuide, thus yielding more accurate guiding result. The ideal focal length is between 400mm and 1200mm. An adjustable guide scope tube ring and a finderscope or red dot finder are recommended for searching for a guide star.

BASIC OPERATIONS 4 It is highly recommended that you familiarize yourself with the basic operations of the SynGuider indoors before going out under the dark sky. ATTACHING SYNGUIDER TO A GUIDE SCOPE There are two ways to install the SynGuider on a guide scope: Option 1: The SynGuider can be threaded onto a telescope with a M42 thread adapter. Generally, this installation method provides the most secure connection. It is best suited for the guide scope equipped with a finderscope or a red dot finder. Option 2: Install the M42-to-1.25 adapter to the main body of the autoguider, and then insert and lock the autoguider into the 1.25 inch eyepiece holder on the guide scope. This installation method is suitable for using a par-focal eyepiece to search for a guide star due to its convenience in exchanging the SynGuider for an eyepiece. CONNECTING CABLES Plug the hand pad into the 8 pin RJ-45 connector on the main body of the autoguider. Plug one end of the guiding cable into the autoguider port on the autoguider and the other end into the equatorial mount. Plug in the battery case or the power supply of your choice. READING THE LCD DISPLAY The LCD display is divided into two zones. The left half of the LCD screen displays text information, such as the menu, data and the status of the device. The right half of the LCD screen displays the image captured by the optical sensor. In the screen, stars are represented by dots.

5 BASIC OPERATIONS USING THE HAND CONTROL There are nine illuminated buttons on the hand pad: Menu: Used to open up the main menu. ESC: Used to cancel an operation or quit from the menu. Enter: Used to enter a submenu or confirm an operation. +: Used to increase the exposure time. -: Used to decrease the exposure time. Up/Down buttons: The function of these buttons depends on the working mode of the autoguider: Preview Mode: Manually toggle the Dec+ and Dec- signal of the ST-4 autoguider port. Menu Mode: Scroll between the menu items. MENU ENTER Data Input Mode: Change the parameters. ESC Manually Lock Guider Star Mode: Move the small pick-up crosshair vertically. Guiding Mode: Set the Dec correction aggressiveness. Left/Right buttons: The function of these buttons depends on the working mode of the autoguider: Preview Mode: manually toggle the RA+ and RA- signal of the ST-4 autoguider interface. Menu Mode: The right button is to enter a submenu. The left button is to confirm a menu operation. It performs as the Enter button. Data Input Mode: The left button is to confirm a menu operation. It performs as the Enter button. Manually Lock Guider Star Mode: Move the small pick-up crosshair horizontally. Guiding Mode: Set the RA correction aggressiveness.

BASIC OPERATIONS 6 OPERATING THE MENUS Press the Menu button to activate the main menu tree. Use the UP or DOWN buttons to scroll through the menu items. Press the ENTER or the RIGHT button to choose between the following submenus: ZM STAR or ZM CTR. Menu: These two menus are usable only when the SynGuider is working under the preview mode. It is used to zoom in on the image. Using the UP/DOWN buttons, choose between the zoom level 1 (the entier image), 2 (384X384 pixels of the image sensor), 3 (128X128 pixels of the image sensor) and 4 (64X64 pixels of the image sensor). After choosing the level, press ENTER to confrim or ESC to keep the previous zoom level. "ZM STAR" tries to use the position of the brightest star in the FOV of the SynGuider as the center of the zoomed image, unless the star is too close to the edge of the image sensor. "ZM CTR." always zooms at the center of the image sensor. LOCK Menu: This submenu is used to lock a star in SynGuider s field of view (FOV) for later guiding operation. After entering this submenu, use UP or DOWN button to choose from the following options and then press ENTER or LEFT button to confirm: AUTO: the SynGuider will try to automatically lock the brightest star in the FOV. MANUAL: the SynGuider will show a small pick-up crosshair in the image area of the LCD display, where you can use the four direction buttons to move the crosshair onto or near a star. Press ENTER to lock the SynGuider on the star. UNLOCK: allow the SynGuider to exit from the locked mode or guiding mode and return to the preview mode Look to the upper left corner of the LCD display to find out which mode the SynGuider is currently working under.

7 BASIC OPERATIONS GUIDE Menu: This menu is used to activate or de-activate autoguiding. Use the UP/DOWN button to choose from the following three options: AUTO CAL: The SynGuider will start an auto-calibration routine prior to the start of autoguiding. RESUME: The SynGuider will immediately start autoguiding with the previous guiding parameters. STOP: The SynGuider will stop autoguiding and return to the locked mode. CROSS Menu: This menu is used to turn on the crosshair on the LCD screen. DEC BACKLASH Menu: To reduce the influence of Dec axis backlash during autoguiding, the SynGuider can send a Dec+ or Dec- control for a pre-determined time when the SynGuider changes the polarity of the Dec control signal. Once this menu is selected, you will see the current setting displayed in the text zone of the LCD screen. Use UP/DOWN buttons to change the value. Press ENTER or LEFT button to confirm. If your equatorial mount has no or minimal backlash, or if you have done very accurate polar alignment, the Dec backlash should be set to 0. NOISE Menu: This menu is used to set the cut-off value for the noise filter of the image sensor. The proper noise level differs from exposure time, thus the SynGuider provide independent noise level setting for each exposure time and will automatically use the corresponding nosie level when the user change the exposure time. Once this submenu is selected, you will see the current cut-off value displayed in the text zone of the LCD, while the image zone of the LCD keeps refreshing. If there is a short solid horizontal line shown in the upper or middle portion of the LCD's image area, it means that the cut-off value is too low and you should increase it until you can see reasonable amount of noise dots diversify evenly in the LCD's image area.

BASIC OPERATIONS 8 If there is no noise spot appear in the image zone of the LCD, it might mean that the cut-off value is set too high and this might reduce the sensitivity of the SynGuider for detecting faint stars. You should reduce the cut-off value until you can see some noise dots diversify evenly in the image area. RESET Menu: This menu resets all the settings back to the factory default settings.

9 OPERATING UNDER THE NIGHT SKY The key steps of operating the SynGuider are: Step 1: Adjust the focus (PREVIEW mode) Step 2: Align the SynGuider with the mount (Very important. Do not skip) Step 3: Find and lock a guide star (LOCKED mode) Step 4: Start autoguiding (GUIDING mode) The following sections explains the practical operations of the SynGuider: ADJUST FOCUS (PREVIEW MODE) The SynGuider enters the PREVIEW mode as soon as the power is turned on. Following is an example of what you will see. The right half of the screen The left half of the LCD screen displays the image detected displays text information. by the sensor. The current mode The current exposure The brightness of the brightest star The position of the brightest star The current zoom level The position of the center of the image window in the sensor s pixel matrix PREVIEW EXP 100 BRI 35 X 105 Y 68 ZOOM 1 X0 0 Y0 0 The brightest star is framed. Stars are represented by dots.

OPERATING UNDER THE NIGHT SKY 10 Follow these steps to adjust the focus of the guide scope: 1). Insert an optical eyepiece into the eyepiece holder of the guide scope. Activate tracking of the mount. Center a bright star in the eyepiece s field of view. 2). Remove the optical eyepiece and replace it with the SynGuider. 3). Use the + or - buttons on the hand pad to set the exposure time to 100 milliseconds. 4). Use the NOISE Menu to set the noise control level until the LCD is free of background noise. 5). Adjust the focuser of the guide scope until the image of the bright star appears in the LCD as a blank dot. Continue to adjust the focuser until the the blank dot appears to be smallest, suggesting that the image is in focus. At this point, if you continue to turn the focuser you will see that the dot becomes larger again. The BRI reading will increase as the image comes into focus. If the BRI reading increases to over 100, use the - button to reduce the exposure time to avoid over-exposure. If the BRI reading still keeps high with minimum exposure, try to use a fainter star for focusing. 6). Use the "ZM STAR" menu to change the zoom level to show more details of the star image. Fine tune the focuser to obtain the smallest star image and the highest BRI reading. Lock the focuser of the guide scope and remove the SynGuider from the guide scope. 7). Now it is the time to make a par-focal eyepiece for later use. A par-focal eyepiece can be used to locate the guide star, or to adjust the focus of the guider scope for subsequently setting up the guider scope. Follow these steps to make a par-focal eyepiece:

11 OPERATING UNDER THE NIGHT SKY 1). Loosen the locking screw on the par-focal ring. Insert an optical eyepiece into the eyepiece holder through the par-focal ring, as shown on the right. 2). Slowly move the eyepiece in and out of the eyepiece holder until the image of the star is the sharpest. Keep the eyepiece still with one hand, and firmly push the par-focal ring against the eyepiece holder with one finger, while tightening the locking screw on the par-focal ring with the other. 3). The par-focal ring should be firmly attached to the eyepiece. You may remove the eyepiece from the guide scope now. Attach the 1.25 extention barrel to the eyepiece if the eyepiece is too short to reach focus. ALIGN SYNGUIDER WITH MOUNT Follow these steps to align the orientation of the autoguider with the moving direction of the two axes of the equatorial mount: 1). Turn on the crosshair on the LCD screen using the CROSS menu. 2). Adjust the autoguider so that when the equatorial mount is slowly slewing in RA axis the star image moves parallel to either the horizontal or the vertical line. Instead of using the hand control of the mount, you may also use the LEFT/RIGHT direction buttons on the SynGuider hand pad to control the RA axis of the mount. Remember or mark the position of the SynGuider on the guide scope so you won t have to perform the autoguider alignment again.

OPERATING UNDER THE NIGHT SKY 12 FINDING AND LOCKING A GUIDE STAR 1). Point the primary telescope to the target deep sky object (DSO). Activate tracking on the equatorial mount. The guide scope should also be pointed to the same region in the sky. 2). Attach the par-focal eyepiece to the guide scope. Locate a brightest star nearby and adjust the guide scope so the star appears in the center of the par-focal eyepiece s FOV. 3). Replace the par-focal eyepiece with the SynGuider. 4). The image of the star should appear in the image zone of the LCD screen. If not, use the + button to increase the exposure time until the image of the star appears. Use the NOISE menu to filter out the noise if the image zone of the LCD screen becomes blank or too noisy.. 5). Now is a good time to adjust the exposure time. Generally speaking, shorter exposure gives better periodic error correction results. The BRI reading on the screen is a good reference. The minimum BRI reading required for the SynGuider to work stably is 20. Try to bring the BRI reading close to 20 for the best result. 6). Adjust the guide scope to bring the star to the center if it is too close to the edge of the image zone on the SynGuider. This is only necessary when the ZOOM level is set at 1. 7). Lock the guide star automatically or manually using the LOCK menu. If the guide star is successfully locked the SynGuider will enter the LOCKED mode. The ZOOM level will automatically be switched to 4, and SynGuider will display an area of 64*64 pixels near the locked star.

13 OPERATING UNDER THE NIGHT SKY The diagram on the right is a example of the LCD display. a) (DX, DY) are the locked star s offset to its original locked position. b) (X0, Y0) are the position of the center of the image in sensor s pixel matrix. c) If the SynGuider lost the guide-star, it will wait until the star re-appears, or user can press the ESC button to return to PREVIEW mode. LOCK: EXP 50 BRI 40 DX 5.32 DY 4.38 X0 120 Y0 35 AUTOGUIDING (GUIDING MODE) Once the SynGuider is successfully locked onto a star, you may active guiding with the GUIDE menu. Activate Autoguiding AUTO CAL: This is recommended when the telescope has been moved to a new object. It will start an auto-calibration routine to detect the correct setting of the guiding parameters, including the polarity of the control signals and the guiding aggressiveness. SynGuider will automatically start autoguiding after the calibration is finished successfully. RESUME: This is to resume previous autoguiding. SynGuider will skip the auto-calibration routine and start autoguiding with the previous guiding parameters.

OPERATING UNDER THE NIGHT SKY 14 The following diagram is what you will see in the GUIDING mode. Exposure time Brightness of the star R.A. and Dec. guiding agressiveness in ms/pixel The drift in R.A. and Dec. in pixels Indication that the SynGuider is sending RA+/RA- or Dec+/Decsignals via the autoguider port. GUIDING EXP 300 BRI 25 GR 220 DG 180 DR -0.39 DD 0.25 RA+ Dec- A crosshair is displayed for you to monitor the effects of autoguiding. The center of the cross is the position of the guide star when guiding is activated. Operations The guiding agressiveness of RA or Dec axis can be adjusted with the direction buttons on the hand control. Use the RIGHT/LEFT buttons to increase/decrease the RA aggressiveness and the UP/DOWN buttons to increase/decrease the Dec agressiveness. If the SynGuider losses the guide-star during autoguiding, it will wait until the star re-appears, or user can press the ESC button to return to PREVIEW mode. Suspend Autoguiding Use menu GUIDE/STOP to stop autoguiding. The exposure on the photographic camera should be stopped before suspending autoguiding.

15 SPECIFICATIONS IMAGE SENSOR Type: APTINA MT9V034C12STM CMOS Sensor Chip size: 4.51mm(X) * 2.88 mm(y) Number of effective pixels: 752(X) * 480(Y) Unit cell size: 6.0um(X) * 6.0um(Y) POWER SUPPLY DC 4.5V~14V, 150mA; a +5V power supply is recommended. Power Jack: 2.1mm, tip positive; or USB type B EXPOSURE TIME 2, 5, 15, 30, 70, 100, 200, 300, 400, 500, 600 ms SENSITIVITY Typically, the SynGuider II can capture and guide a star with up to the magnitude of 8.5 under the following conditions: Regular 80mm aperture refractor, 500ms exposure time, and good seeing conditions