Prostar XL Percutaneous Vascular Surgical Device

Similar documents
Perclose ProGlide. Deployment Steps. Suture-Mediated Closure System Abbott. All rights reserved. ANZ /11

Techniques of the hand tie and instrument tie

Objectives. xxx00.#####.ppt 5/10/17 9:42 AM

PARS Achilles Jig System

Interlagos Retractor System Surgical Technique

Fax Japan São Paulo (SP) Tokyo Minato-ku , Minami-Aoyama. St. Jude Medical Brasil Ltda.

LabraLock P for Labrum Repair, LabraFix System. The Reinforcement Technique Guide

Arthroscopic Protector Meniscus Suturing Surgical Techniques

MIS TECHNOLOGY GUIDE READ PRODUCT INSERT THOROUGHLY BEFORE USE

VERSALOK. Suture Anchor. Rotator Cuff Repair Surgical Technique

ARTHROSCOPIC ROTATOR CUFF REPAIR SURGICAL TECHNIQUE. The following techniques are described by Vernon J. Cooley, M.D.

PARS Achilles Jig System Surgical Technique

Electron Microscopy Sciences

Basic Instructions. The Ring: Fill the shuttle with thread from a ball DMC or Coats 20, but DO NOT CUT from the ball.

7878 K940. Checkpoint Antenna. Kit Instructions. Issue B

Procedure Guide. Eliminate Big Problems Safely and Quickly Close Your Patients Port Sites

University of Alabama at Birmingham. ObGyn Residency. Laparoscopy Training Lab PGY 1-4. Individual Pelvic Trainer Tasks

Double Row Rotator Cuff Repair. Surgical Protocol by Frank Bonnarens, M.D.

D. Greg Anderson, MD Thomas Jefferson University Hospital Philadelphia, PA

The OPUS AutoCuff System for Rotator Cuff Repair

Top Innovations, Inc. Innovative Products to Make Your Life Easier. Model SP-402 Owner s Manual

Wiring Techniques for Wiring a Lamp

Leading the Way in Guide Wire Technology

Champion Instrumentation. Shoulder Repair Made Simpler

Kromski Symphony Assembly Instructions

STOP! READ THIS FIRST

Kromski Minstrel Assembly Instructions

Reflex TM Surgical Technique. Anterior Cervical Plate

Dr. S.D. Gerber Double Row Method Surgical Technique

Simple Interrupted Suture (using a silicon skin pad)

ASAHI Peripheral Guide Wire

Simple Interrupted Suture (using a tea towel)

Fiber Splice Box (FSB-D) Installation Instructions

MIL-STD B (SH) UPDATE

INSTALLATION GUIDE 2009-CURRENT HUMMER H3T PRODUCT CODE:

Pacific Antenna 20 and 40M Lightweight Dipole Kit

The use of sutures and ligatures is an integral part of surgical procedures. Being proficient in suturing and ligating will not only make your

How to Set Up Your Rick s Bead Loom (TL2862)

Technique Guide. Modular Sternal Cable System. Flexibility and strength in sternal closure and repair.

HOW TO WARP A LOOM By Cindy Dean

J-470 ELECTROSURGE. Radio Frequency Electrosurgery Unit. Operation Instructions

Replacing the Reciprocator on the SWF Compact Series Machine (601C and 1201C)

Rotator Cuff Repair ICONN Answer PEEK Suture Anchor 4.75/5.5. Surgical Protocol by Geoffrey Connor, 4.75/5.5 MD of D1 Sports Medicine

Replace rubber band. This guide can be used on any piece of garment with a worn elastic band, for example pajamas or sweatpants, or skirts.

Arthroscopic Rotator Cuff Repair

Double Row Rotator Cuff Repair. Surgical Protocol by Frank Bonnarens, M.D.

squid amigurumi free crochet pattern

Knotless SutureTak Instability Repair. Surgical Technique

GP-SD GENIE PROBE SMALL DIAMETER

OVERVIEW. Mounting Post (2 places) Cylinder Cam. Handing Pin

jellyfish amigurumi free crochet pattern

DCD Design & Model K (400) Part #: Pull Type Cable Lasher Operating Instructions. Manufacturing Ltd. ENGINEERING SOLUTIONS

V-Groover SIMPLEX INSTRUCTION AND OPERATION MANUAL M O DEL 703. For best results use only authentic Logan blades.

2. Connect driver to power source leads. After connections are made, place driver above ceiling. SEE MINIMUM SPACE REQUIREMENTS BELOW.

EURO DELUXE INSTALLATION INSTRUCTIONS

MANUAL CARTON STAPLER MODEL: H-1025 MANUAL

* * 98/9950WDC. Fire-Rated Devices include these. additional components. 1-Point Latch (LBL)

Quick Fit Installation Guide Retractable Screen - Double Door

Marcia DeCoster. Bead Art and Instruction.

Removing and Replacing the Y-truck

High Speed Air Turbine Handpiece

Super Revo. Surgical Technique. Super Revo Shoulder Fixation System. The Ideal Fixation Device For Rotator Cuff Repair. Self-drilling, titanium anchor

Getting to Know: A-LINE SERIES Model BL450A. Baby Lock Consumer Helpline:

Pacific Antenna 20 and 40M Lightweight Dipole Kit

General Wood Shop Notes

KneeWalkersForRent.com How to Set Up and Adjust Your Knee Walker

Casting Tool Kit, from Jewelry Television. Introduction. Tools That Come With The Casting Kit

BERNINA. Overlocker Workbook 2

The Ballistic Blaster Rocket Kit should contain the following items. If anything is missing, call Customer Service at

41P PFAFF HOBBY SERGER

Kromski Prelude. Assembly Instructions

COMPACT XL MAT CUTTER

Instructions for Preparing AFL OPTICAL GROUND WIRE CABLE (ALUMACORE CABLE DESIGNS) FOR BPA

Quick Fit Installation Guide Retractable Screen - Single Door

3. X-axis assembly. 3. X-axis assembly. Written By: Jakub Dolezal manual.prusa3d.com/ Page 1 of 13

Decorative Briolettes

Print Head Installation Guide

STILLE Micro Instruments. Solid Performance - Outstanding Precision

Pacific Antenna 20 and 40M Lightweight Dipole Kit

Installation Instructions

The wick in your heater needs replacing if, after repeated cleanings, any of the following conditions still exist:

Tyler Alignment & Calibration System For the Leksell Stereotactic Frame

KIT. Assembly Instructions. HayDay, LLC

Four-Thread Safety Stitch

Kwikset, Titan, Ultramax Comparison Eugene Hansen 2004

ExpresSew II. Intuition redefined.

Design Brief: Mousetrap Racer

Replacing the Reciprocator on an SWF Multi-head.

Restoration Project Photo Essay

Hollywood Swing Away 2 and 4 Bike Racks Assembly and Installation Guide

Electric Skein Winder

Travel Trailer Latch With Dead Bolt Trailer Latch With Dead Bolt. U.S. Patent No. 5,927,773

SIDE FOLDING POST ADJUSTMENTS

Setup & Operating INSTRUCTIONS. for (FOR PIN FITTING AND ROD RECONDITIONING)

001-Component-build. Build the following Contraptor components before assembly:

1.1.1 The cube assembly has two filter retainer rings; one is located on the Exciter side and one is on the Emitter side as shown below.

Tensioning Instructions

For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY.

AG19 10 OC Cantilever. Assembly and Operation Guide

The Bowflex Revolution XP Home Gym Assembly Instructions. P/N: Rev ( /0 )

Transcription:

Clinical leader for percutaneous large access site closure Close Access Sites Up to 24F Secure Closure Prostar XL Percutaneous Vascular Surgical Device Improved Outcomes 2009 Abbott Laboratories. All rights reserved. EHQ 6002-01 07/2009

KNOT PUSHER Marker Lumen Suture Lumens Star Hub Handle Interlocks Marker Port Barrel Guide Wire Exit Port Sutures Nitinol Needles Sheath 2

MARKING Suture Lumens Marker Lumen 45º 360º Hub Marker Port Unlock the Hub by depressing the Interlocks with the thumb and forefinger. Once the Hub is unlocked, rotate the Hub while gently advancing the barrel at a 45º angle. A steady, continuous drip of blood from the Marker Lumen occurs when the Prostar Device is properly positioned. Marking from the Suture Lumens may occur but should not be used as an indicator for proper positioning. 3

NEEDLE DEPLOYMENT Pulsatile Marking Marker Lumen Needle Tips STAR Hub Handle Suture Lumens 45º 4 Visually confirm that the STAR embossed on the hub is at the 12-o'clock position during deployment. Confirm that the Interlocks are re-engaged and correctly aligned with the locking indents in the Hub. Hold the Hub of the Prostar Device in position with the left hand while deploying needles with the right hand. Maintaining a 45 degree angle, rotate the handle counter-clockwise 90º and pull the handle straight back away from the Hub to deploy the needles. If needles are not easily deployed, back the needles down into the sheath prior to device removal.

NEEDLE REMOVAL Hub Verify that all needles are present. Using the Hub as a fulcrum, remove the posterior needles first. 5

BOWSTRINGING Sheath Apply tension to suture ends Sheath should be bent outward away from the operator. Grab the suture adjacent to the sheath and pull the ends through the distal end of the barrel. 6

PRE-CLOSE TECHNIQUE Anterior Sutures Posterior Sutures Interarterial view of sutures with one device Access sites larger than 10F require the use of the pre-close technique (placement of the Prostar XL device sutures prior to dilating the access site beyond 10F) When utilizing a pre-close technique, the Prostar XL device is exchanged for an appropriately sized introducer sheath or additional Prostar XL device if additional sutures are to be placed around the same access site. 7

SECOND DEVICE PLACEMENT 45 rotation Sutures from First Device STAR Interarterial view of sutures with two devices Access sites larger than 10F may require the use of an additional device. If additional sutures are to be placed, position an additional Prostar XL device rotated 45 degrees relative to the first Prostar XL device to establish alternating suture positions. 8

SECOND DEVICE SUTURE MANAGEMENT Sutures from Second Device Sutures from First Device Identify and secure the sutures from the first device separately from the sutures of the additional device. 9

KNOT TYING 1 2 3 4 5 6 Non-Rail Non-Rail Non-Rail Non-Rail Non-Rail Rail Rail Rail Rail Rail 1 To tie a knot, place a hemostat between both suture tails. 2 Decide which tail will be the rail (slides knot) and non-rail (knot). Wrap the non-rail around the rail five (5) times. 3 Place the tip of the non-rail through the loop you created with the hemostats. This creates a second loop. 4 Now place the tip of the non-rail tail through the second loop. 5 You can remove some of the slack in the knot by pulling gently on the non-rail being careful not to pull too tightly. Remove the hemostats. 6 As you remove slack, do not pull too tightly or you will lock the knot. If the knot is locked prematurely, you will not be able to advance the knot. To advance the knot using the Knot Pusher, securely wrap the rail around your left index finger. 10

PRE-CLOSE TECHNIQUE KNOT TYING When utilizing a pre-close technique, sliding, self-locking surgical knots should be tied prior to introducer sheath removal. Sutures should be gradually tightened as the introducer sheath is removed to maintain hemostasis. 11

KNOT PUSHER USAGE Thumb Knob Window Suture Retract the Thumb Knob on the handle and position the suture across the window located at the distal end of the Knot Pusher. Release the Thumb Knob to load the suture. 12

SINGLE HAND KNOT ADVANCEMENT White suture is closest to artery Interarterial view of sutures with one device White suture of first device is closest to artery Interarterial view of sutures with two devices The White Suture must be tied first because it is the closest suture to the artery. If using an additional, the white suture of the first device should be tied first, followed by green and repeated for the second device. This step eliminates the possibility of trapping the White Suture. To avoid an air knot apply tension to the suture while advancing the knot. Tension must be applied to remove slack in the suture while advancing the knot. 13

HEMOSTASIS Apply constant, gentle pressure to the Knot Pusher and pull on the suture wrapped around index finger until hemostasis is achieved. Remove guide wire before locking the knot. Alternate between the green and white sutures to achieve hemostasis. Once hemostasis is achieved, trim the sutures below the skin. 14

NEEDLE BACKDOWN Needles LATERAL VIEWS Radiopaque Sheath Ring If needles are not easily deployed, back the needles down into the sheath prior to device removal. Use cine to identify the position of the needle tips, prior to backing down the needles. Use a needle holder to grasp the pull rod a few millimeters proximal to their exit from the device core. Manually remove the coiled sections of the suture lumens to uncover the suture loops. Gently feed the pull rod back into the core and gently pull the slack out of the uncovered suture loops one centimeter at a time until the handle snaps. Verify that the needle tips are as close as possible to the proximal edge of the radiopaque sheath ring prior to device removal. Rotate the handle counterclockwise 90 degrees to lock back to the initial position 15

Prostar XL is a trademark of the Abbott Group of Companies. Please contact your local representative for more information. Abbott Vascular International BVBA Park Lane Culliganlaan 2B, 1831 Diegem BELGIUM This product in intended for use by or under the direction of a physician. Prior to use, it is important to read the package insert thoroughly for instructions for use, warnings and potential complications associated with use of this device. Information contained herein for distribution outside the U.S. and Japan only. Please check the regulatory status of the device before distribution in areas where CE marking is not the regulation in force. For more information, visit our website at abbottvascular.com 2009 Abbott Laboratories. All rights reserved. EHQ 6002-01 07/2009