SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT

Similar documents
SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT B.Tech. [SEM I (EE, EN, EC, CE)] QUIZ TEST-3 (Session: ) Time: 1 Hour ELECTRICAL ENGINEE

Aligarh College of Engineering & Technology (College Code: 109) Affiliated to UPTU, Approved by AICTE Electrical Engg.

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

VALLIAMMAI ENGINEERING COLLEGE

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad ELECTRICAL AND ELECTRONICS ENGINEERING

Code No: R Set No. 1

Reg. No. : BASIC ELECTRICAL TECHNOLOGY (ELE 101)

Module 1. Introduction. Version 2 EE IIT, Kharagpur

Hours / 100 Marks Seat No.


1. (a) Determine the value of Resistance R and current in each branch when the total current taken by the curcuit in figure 1a is 6 Amps.

Hours / 100 Marks Seat No.

3. What is hysteresis loss? Also mention a method to minimize the loss. (N-11, N-12)

INSTITUTE OF AERONAUTICAL ENGINEERING (AUTONOMOUS) Dundigal, Hyderabad

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

PART A. 1. List the types of DC Motors. Give any difference between them. BTL 1 Remembering

MAHARASHTRA STATE BOARD OF TECHNICAL EDUCATION

INSTITUTE OF AERONAUTICAL ENGINEERING (AUTONOMOUS)

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

INSTITUTE OF AERONAUTICAL ENGINEERING Dundigal, Hyderabad

1. A battery has an emf of 12.9 volts and supplies a current of 3.5 A. What is the resistance of the circuit?

86 chapter 2 Transformers

ELECTRICAL TECHNOLOGY

148 Electric Machines

Code No: R Set No. 1

PROBLEMS on Transformers

EEE3441 Electrical Machines Department of Electrical Engineering. Lecture. Basic Operating Principles of Transformers

Placement Paper For Electrical

Downloaded From All JNTU World

UNIVERSITY OF TECHNOLOGY By: Fadhil A. Hasan ELECTRICAL MACHINES

Module 7. Transformer. Version 2 EE IIT, Kharagpur

COLLEGE OF ENGINEERING DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING ACADEMIC YEAR / EVEN SEMESTER QUESTION BANK

QUESTION BANK ETE (17331) CM/IF. Chapter1: DC Circuits

Downloaded From JNTU World. B.Tech II Year II Semester (R09) Supplementary Examinations December/January 2014/2015 GENERATION OF ELECTRIC POWER

Dhanalakshmi Srinivasan Institute of Technology, Samayapuram, Trichy. Cycle 2 EE6512 Electrical Machines II Lab Manual

THE UNIVERSITY OF BRITISH COLUMBIA. Department of Electrical and Computer Engineering. EECE 365: Applied Electronics and Electromechanics

MAHARASHTRA STATE BOARD OF TECHNICAL EDUCATION

SIDDHARTH GROUP OF INSTITUTIONS :: PUTTUR (AUTONOMOUS) Siddharth Nagar, Narayanavanam Road QUESTION BANK (DESCRIPTIVE) UNIT I INTRODUCTION

Transformer & Induction M/C

CHAPTER 2. Transformers. Dr Gamal Sowilam

TRANSFORMERS PART A. 2. What is the turns ratio and transformer ratio of transformer? Turns ratio = N2/ N1 Transformer = E2/E1 = I1/ I2 =K

Introduction : Design detailed: DC Machines Calculation of Armature main Dimensions and flux for pole. Design of Armature Winding & Core.

Level 6 Graduate Diploma in Engineering Electro techniques

Chapter 2-1 Transformers

EE 350: Electric Machinery Fundamentals

Electrical Machines (EE-343) For TE (ELECTRICAL)

MAHARASHTRA STATE BOARD OF TECHNICAL EDUCATION

ELECTROMAGNETIC INDUCTION AND ALTERNATING CURRENT (Assignment)

Transformers. gpmacademics.weebly.com

GATE SOLVED PAPER - EE

Code No: RR Set No. 1

Unit FE-5 Foundation Electricity: Electrical Machines

Electrical Workstation Nvis 7089A

Code No. : 09(1) Roll No...

Electrical Workstation Nvis 7089B

ELECTRICAL MEASUREMENTS

Electrical Machines I : Transformers

Bhoj Reddy Engineering College for Women, Hyderabad Department of Electronics and Communication Engineering Electrical and Electronics Instrumentation

PESIT Bangalore South Campus Hosur road, 1km before Electronic City, Bengaluru -100 Department of Electronics & Communication Engineering

ELECTRICAL ENGINEERING LABORATORY MANUAL (NEE 151/251)

Manuals. Basic Electrical Engineering BE-104

MAHARASHTRA STATE BOARD OF TECHNICAL EDUCATION

Spring 2000 EE361: MIDTERM EXAM 1

1. Explain in detail the constructional details and working of DC motor.

SYNCHRONOUS MACHINES

No. of Printed Pages : 5 ADVANCED LEVEL CERTIFICATE COURSE IN ELECTRICAL ENGINEERING / DIPLOMA IN ELECTRICAL ENGINEERING / ACELVI / DELVI

CHIEF ENGINEER REG III/2 MARINE ELECTROTECHNOLOGY

REV NO EXPERIMENT NO 1 AIM: To perform open and short circuit tests on 1-phase transformer and to calculate efficiency. Apparatus required:

Table of Contents. Table of Figures. Table of Tables

TRANSFORMER THEORY. Mutual Induction

VS JE _D Please read the instructions carefully before attending the Question paper. All Questions are compulsory.

MGVCL VSJE - Question Booklet Code "A"

2015 ELECTRICAL SCIENCE

Conventional Paper-II-2013

Question Paper Profile

Unit 3 Magnetism...21 Introduction The Natural Magnet Magnetic Polarities Magnetic Compass...21

PART B. t (sec) Figure 1

Preface...x Chapter 1 Electrical Fundamentals

PRACTICAL WORK BOOK. Basic Electrical & Electronics Engineering BE-104

Experiment 45. Three-Phase Circuits. G 1. a. Using your Power Supply and AC Voltmeter connect the circuit shown OBJECTIVE

Alternating Current. Slide 1 / 69. Slide 2 / 69. Slide 3 / 69. Topics to be covered. Sources of Alternating EMF. Sources of alternating EMF

Alternating Current. Slide 2 / 69. Slide 1 / 69. Slide 3 / 69. Slide 4 / 69. Slide 6 / 69. Slide 5 / 69. Topics to be covered

Three-Phase Induction Motors. By Sintayehu Challa ECEg332:-Electrical Machine I

GOPALAN COLLEGE OF ENGINEERING AND MANAGEMENT. Electronics and communication Department 6. COURSE PLAN

EQUIVALENT CIRCUIT OF A SINGLE-PHASE TRANSFORMER

L T P EE 441: Analog Electronics (EE/IE) (3 1 3) Theory Marks =100 Sessional Marks = 50 Laboratory Marks = 50 Time = 3 hours

GATE 2000 Electrical Engineering

ENGINEERING ACADEMY X V

Walchand Institute of Technology. Basic Electrical and Electronics Engineering. Transformer

AP Physics C. Alternating Current. Chapter Problems. Sources of Alternating EMF

GOPALAN COLLEGE OF ENGINEERING AND MANAGEMENT. Electronics and communication Department 6. COURSE PLAN

LECTURE NOTES ON ELECTRICAL MACHINE-II. Subject Code-PCEL4302

Downloaded from / 1

S J P N Trust's Hirasugar Institute of Technology, Nidasoshi.

CHAPTER 6: ALTERNATING CURRENT

UNIT II MEASUREMENT OF POWER & ENERGY

BASIC ELECTRICAL AND ELCTRONICS ENGINEERING LABORATORY LAB MANUAL

3.1.Introduction. Synchronous Machines

Practical Transformer on Load

Transcription:

SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT B.Tech. [SEM I (CE,EC,EE,EN)] QUIZ TEST-3 (Session: 2012-13) Time: 1 Hour ELECTRICAL ENGINEERING Max. Marks: 30 (EEE-101) Roll No. Academic/26 Refer/WI/ACAD/18 Note: Attempt All Questions. (To be filled by the Student) Part A (Questions from Tutorial Sheet) [10 Marks] Q1) A balanced 3-phase load consists of three coil, each having resistance of 6 ohm & inductive reactance of 8 ohm. Determine line current and power absorbed when coils are (a) star connected (b) delta connected, across 400V, 3 phase supply. [Q-02] [2.5+2.5] Q2) Explain the principal and operation of PMMC instrument. [Q-10] [5] Part B [20 Marks] Q3) Short answer type question: (a) Write down the advantage and disadvantage of one wattmeter method. [1] (b)what are the standard primary and secondary transmission voltages? [1] (c) What do understand by Shunt? [1] (d) Why damping torque is required in instruments? [1] (e) Define turn ratio and transformation ratio. [1] Q4) In an R-L series circuit the voltage and current is expressed as, [1+2+1+1] v(t) = 30 sin (314t + 5π/6) and i(t) = 10 sin (314t + 2π/3) find (i) Impedance of circuit (ii) R and L connected in circuit (iii) The average power (iv) Power factor of the circuit Q5) Draw and explain hysteresis loop, also write down the importance of hysteresis loop. [4+1] Q6) A 11000/230V, 150 KVA, single phase 50 Hz transformer has core loss of 1.4 KW and full load copper loss of 1.6 KW. Determine [3+2] (i) KVA loading for maximum efficiency and value of maximum efficiency at unity power factor (ii) The efficiency at 50% of full load at 0.8 power factor lagging. -------------------X-------------------- EEE-101/Mr.B.K.Verma, Mr.Gaurav Sharma, Ms.Kavya Mittal, Mr.Gaurav Singh, Mr. Anjanee kr. Mishra Date: 17/11/2012 Page-1

SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT B.Tech. [SEM I (CE,EC,EE,EN)] QUIZ TEST-3 (Session: 2012-13) Time: 1 Hour ELECTRICAL ENGINEERING Max. Marks: 30 (EEE-101) Roll No. Academic/26 Refer/WI/ACAD/18 Note: Attempt All Questions. (To be filled by the Student) Part A (Questions from Tutorial Sheet) [10 Marks] Q1) A 400V supply is connected across a balanced load of three impedances each consisting of 32 ohm resistance and 24 ohm inductive reactance in series. Determine the current drawn from power mains if three impedances are (a) star connected (b) delta connected. [Q-04] [2.5+2.5] Q2) Explain power measurement in three phase by two wattmeter method for balanced star connected load. [Q-07] [5] Part B [20 Marks] Q3) Short answer type question: (a) Write down the advantage and disadvantage of three wattmeter method. [1] (b)what are the standard primary and secondary distribution voltages? [1] (c) What do understand by Multiplier? [1] (d) Why controlling torque is required in instruments? [1] (e) Define primary and secondary winding. [1] Q4) In an R-L series circuit the voltage and current is expressed as, [1+2+1+1] v(t) = 30 sin (314t + 5π/6) and i(t) = 10 sin (314t + 2π/3) find (i) Impedance of circuit (ii) R and L connected in circuit (iii) The average power (iv) Power factor of the circuit Q5) Draw and explain hysteresis loop, also write down the importance of hysteresis loop. [4+1] Q6) A 11000/230V, 150 KVA, single phase 50 Hz transformer has core loss of 1.4 KW and full load copper loss of 1.6 KW. Determine [3+2] (i) KVA loading for maximum efficiency and value of maximum efficiency at unity power factor (ii) The efficiency at 50% of full load at 0.8 power factor lagging. -------------------X-------------------- EEE-101/Mr.B.K.Verma, Mr.Gaurav Sharma, Ms.Kavya Mittal, Mr.Gaurav Singh, Mr. Anjanee kr. Mishra Date: 17/11/2012 Page-1

SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT B.Tech. [SEM I (CE,EC,EE,EN)] QUIZ TEST-3 (Session: 2012-13) Time: 1 Hour ELECTRICAL ENGINEERING Max. Marks: 30 (EEE-101) Roll No. Academic/26 Refer/WI/ACAD/18 Note: Attempt All Questions. (To be filled by the Student) Part A (Questions from Tutorial Sheet) [10 Marks] Q1) Explain (a) Phase current (b) Line current (c) Phase voltage (d) Line voltage. Prove that line voltage is 1.732 times its phase voltage in star connection. [Q-05] [2+3] Q2) An energy meter has a registration constant of 100 rev/kwhr. If the meter is connected to a load drawing 20amp at 230V and 0.8 pf for 5 hrs. find the number of revolutions should be made to it. If it actually makes 1800 revolutions then find the percentage error. [Q-11] [3+2] Part B [20 Marks] Q3) Short answer type question: (a) Write down any two advantage of three phase over single phase system. [1] (b)what is the role of circuit breaker in power system? [1] (c) Why PMMC instruments are not suitable for ac measurement? [1] (d) What are indicating type instrument? [1] (e) Define hv and lv winding in transformer. [1] Q4) In an R-L series circuit the voltage and current is expressed as, [1+2+1+1] v(t) = 30 sin (314t + 5π/6) and i(t) = 10 sin (314t + 2π/3) find (i) Impedance of circuit (ii) R and L connected in circuit (iii) The average power (iv) Power factor of the circuit Q5) Draw and explain hysteresis loop, also write down the importance of hysteresis loop. [4+1] Q6) A 11000/230V, 150 KVA, single phase 50 Hz transformer has core loss of 1.4 KW and full load copper loss of 1.6 KW. Determine [3+2] (i) KVA loading for maximum efficiency and value of maximum efficiency at unity power factor (ii) The efficiency at 50% of full load at 0.8 power factor lagging. -------------------X-------------------- EEE-101/Mr.B.K.Verma, Mr.Gaurav Sharma, Ms.Kavya Mittal, Mr.Gaurav Singh, Mr. Anjanee kr. Mishra Date: 17/11/2012 Page-1

SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT B.Tech. [SEM I (CE,EC,EE,EN)] QUIZ TEST-3 (Session: 2012-13) Time: 1 Hour ELECTRICAL ENGINEERING Max. Marks: 30 (EEE-101) Roll No. Academic/26 Refer/WI/ACAD/18 Note: Attempt All Questions. (To be filled by the Student) Part A (Questions from Tutorial Sheet) [10 Marks] Q1) The power input to a 200V, 50Hz 3phase motor running on full load at an efficiency of 90% is measured by two wattmeter which indicates 300KW and 100KW respectively. Find (a)input power (b) Power factor (c) line current and power output. [Q-08] [1+2+2] Q2) A PMMC instrument gives full scale reading of 25mA when a potential difference across its terminal is 75mV. Show how it can be used (a) As an ammeter for range 0-100A (b) As a voltmeter for range 0-75V. Also find multiplying power of the shunt and voltage amplification. [Q-09] [2+2+1] Part B [20 Marks] Q3) Short answer type question: (a) Write down any two advantage of PMMC instrument. [1] (b)what is the role of Cu shading band in energy meter? [1] (c) Show analogy between electric and magnetic circuit in terms of driving force and response. [1] (d) What are recording type instruments? [1] (e) Define Ideal transformer. [1] Q4) In an R-L series circuit the voltage and current is expressed as, [1+2+1+1] v(t) = 30 sin (314t + 5π/6) and i(t) = 10 sin (314t + 2π/3) find (i) Impedance of circuit (ii) R and L connected in circuit (iii) The average power (iv) Power factor of the circuit Q5) Draw and explain hysteresis loop, also write down the importance of hysteresis loop. [4+1] Q6) A 11000/230V, 150 KVA, single phase 50 Hz transformer has core loss of 1.4 KW and full load copper loss of 1.6 KW. Determine [3+2] (i) KVA loading for maximum efficiency and value of maximum efficiency at unity power factor (ii) The efficiency at 50% of full load at 0.8 power factor lagging. -------------------X-------------------- EEE-101/Mr.B.K.Verma, Mr.Gaurav Sharma, Ms.Kavya Mittal, Mr.Gaurav Singh, Mr. Anjanee kr. Mishra Date: 17/11/2012 Page-1

EEE-101/Mr.B.K.Verma, Mr.Gaurav Sharma, Ms.Kavya Mittal, Mr.Gaurav Singh, Mr. Anjanee kr. Mishra Date: 17/11/2012 Page-2

SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT B.Tech. [SEM I (CE,EC,EE,EN)] QUIZ TEST-3 (Session: 2012-13) Time: 1 Hour ELECTRICAL ENGINEERING Max. Marks: 30 (EEE-101) Roll No. Academic/26 Refer/WI/ACAD/18 Note: Attempt All Questions. (To be filled by the Student) Part A (Questions from Tutorial Sheet) [10 Marks] Q1) Three identical resistors of 20 ohm each are connected in star to 415V, 50Hz 3 phase. Calculate (i)the total power consumed (ii)total power consumed if they are connected in delta (iii) The total power consumed if one of the resistor is opened. [Q-06] [2+2+1] Q2) A three phase motor load has a p.f. of 0.397 lagging. Two watt meters are connected to measure power, shows the input as 30kW. Find the reading of each wattmeter. [Q-15] [5] Part B [20 Marks] Q3) Short answer type question: (a) Define deflecting torque. [1] (b)what is creeping error occurs in energy meter? [1] (c) Show analogy between electric and magnetic circuit in terms of impedance and density. [1] (d) What are integrating type instruments? [1] (e) Define hysteresis loss in transformer. [1] Q4) In an R-L series circuit the voltage and current is expressed as, [1+2+1+1] v(t) = 30 sin (314t + 5π/6) and i(t) = 10 sin (314t + 2π/3) find (i) Impedance of circuit (ii) R and L connected in circuit (iii) The average power (iv) Power factor of the circuit Q5) Draw and explain hysteresis loop, also write down the importance of hysteresis loop. [4+1] Q6) A 11000/230V, 150 KVA, single phase 50 Hz transformer has core loss of 1.4 KW and full load copper loss of 1.6 KW. Determine [3+2] (i) KVA loading for maximum efficiency and value of maximum efficiency at unity power factor (ii) The efficiency at 50% of full load at 0.8 power factor lagging. -------------------X-------------------- EEE-101/Mr.B.K.Verma, Mr.Gaurav Sharma, Ms.Kavya Mittal, Mr.Gaurav Singh, Mr. Anjanee kr. Mishra Date: 17/11/2012 Page-1

SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT B.Tech. [SEM I (CE,EC,EE,EN)] QUIZ TEST-4 (Session: 2012-13) Time: 1 Hour ELECTRICAL ENGINEERING Max. Marks: 30 (EEE-101) Roll No. Academic/26 Refer/WI/ACAD/18 Note: Attempt All Questions. (To be filled by the Student) Part A (Questions from Tutorial Sheet) [10 Marks] Q1) Describe the layout of electric power system in India and also explain the function of its various elements in power system. [Q-01] [2+3] Q2) A single phase transformer is working at unity power factor has a efficiency of 90% at both full load and half load of 500W.Determine the efficiency at 75% full load and maximum efficiency.[q-09] [3+2] Part B [20 Marks] Q3) Short answer type question: (a) Write down the advantage of two wattmeter method. [1] (b)define slip and slip speed. [1] (c) Write down the role of Commutator used in dc machine. [1] (d) Why single phase induction motors are not self starting? [1] (e) Write down the use of 1:1 turn ratio transformer. [1] Q4) A 3-phase delta connection 440V, 50Hz 4 pole induction motor has a rotor standstill emf per phase of 130V. If the motor speed is 1440rpm. Then calculate; (i) slip (ii) frequency of rotor induced emf (iii) rotor Induced emf per phase (iv) stator to rotor turn ratio. [2+1+1+1] Q5) Three coils having resistance of 20 ohm and inductive reactance of 15 ohm are connected in star to a 400V 50 Hz 3-phase supply. Calculate the line current, the active power and power factor. If three capacitors each having same value are connected in delta to the same supply so as to form a parallel circuit with above coils calculate. (i)the capacitance to obtain the resultant power factor of 0.95 lagging. (ii)the line current taken by combined load. [2+3] Q6) A single phase 440V/110V transformer takes a no load current of 4A at 0.2 power factor. If the Secondary supplies a current of 100A at a power factor of 0.8 lagging. Determine (i)the current taken by primary winding. (ii)the magnetizing reactance and resistance representing core losses. [3+2] -------------------X-------------------- EEE-101/Mr.B.K.Verma, Mr.Gaurav Sharma, Ms.Kavya Mittal, Mr.Gaurav Singh, Mr. Anjanee kr. Mishra Date: 08/12/2012 Page-1

SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT B.Tech. [SEM I (CE,EC,EE,EN)] QUIZ TEST-4 (Session: 2012-13) Time: 1 Hour ELECTRICAL ENGINEERING Max. Marks: 30 (EEE-101) Roll No. Academic/26 Refer/WI/ACAD/18 Note: Attempt All Questions. (To be filled by the Student) Part A (Questions from Tutorial Sheet) [10 Marks] Q1) Enumerate the similarities and differences between Electric and Magnetic circuit. [Q-03] [3+2] Q2) A 10 KVA 2000/400V single phase transformer has R1=5 ohm, X1=12 ohm, R2=0.2ohm and X2=0.48 Ohm. Determine the equivalent impedance of transformer referred to primary and secondary side. [Q-10] [2.5+2.5] Part B [20 Marks] Q3) Short answer type question: (a) What do you understand by magnetic leakage associated with magnetic circuit? [1] (b)write down the applications of dc series motor. [1] (c) Write down the role of Pole shoe used in dc machine. [1] (d) Why three phase induction motors are self starting? [1] (e) Why brake magnet is used in energy meter? [1] Q4) A 3-phase delta connection 440V, 50Hz 4 pole induction motor has a rotor standstill emf per phase of 130V. If the motor speed is 1440rpm. Then calculate; (i) slip (ii) frequency of rotor induced emf (iii) rotor Induced emf per phase (iv) stator to rotor turn ratio. [2+1+1+1] Q5) Three coils having resistance of 20 ohm and inductive reactance of 15 ohm are connected in star to a 400V 50 Hz 3-phase supply. Calculate the line current, the active power and power factor. If three capacitors each having same value are connected in delta to the same supply so as to form a parallel circuit with above coils calculate. (i)the capacitance to obtain the resultant power factor of 0.95 lagging. (ii)the line current taken by combined load. [2+3] Q6) A single phase 440V/110V transformer takes a no load current of 4A at 0.2 power factor. If the Secondary supplies a current of 100A at a power factor of 0.8 lagging. Determine (i)the current taken by primary winding. (ii)the magnetizing reactance and resistance representing core losses. [3+2] -------------------X-------------------- EEE-101/Mr.B.K.Verma, Mr.Gaurav Sharma, Ms.Kavya Mittal, Mr.Gaurav Singh, Mr. Anjanee kr. Mishra Date: 08/12/2012 Page-1

SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT B.Tech. [SEM I (CE,EC,EE,EN)] QUIZ TEST-4 (Session: 2012-13) Time: 1 Hour ELECTRICAL ENGINEERING Max. Marks: 30 (EEE-101) Roll No. Academic/26 Refer/WI/ACAD/18 Note: Attempt All Questions. (To be filled by the Student) Part A (Questions from Tutorial Sheet) [10 Marks] Q1) What is auto transformer? Give its advantages and disadvantages over single phase transformer. [Q-12] [1+2+2] Q2) The efficiency of 400 KVA, single phase transformer is 98.77% when delivering full load at 0.8 power factor lagging and 99.13% at half load at unity power factor. Calculate the iron losses and the copper losses. [Q-11] [2.5+2.5] Part B [20 Marks] Q3) Short answer type question: (a) Write down one difference between energy meter and wattmeter. [1] (b) Explain why series motor is never started on no load. [1] (c) Explain fringing phenomenon occurred in magnetic circuit. [1] (d) What is the role of auxiliary winding in single phase induction motor? [1] (e) Why copper losses are known as variable losses? [1] Q4) A 3-phase delta connection 440V, 50Hz 4 pole induction motor has a rotor standstill emf per phase of 130V. If the motor speed is 1440rpm. Then calculate; (i) slip (ii) frequency of rotor induced emf (iii) rotor Induced emf per phase (iv) stator to rotor turn ratio. [2+1+1+1] Q5) Three coils having resistance of 20 ohm and inductive reactance of 15 ohm are connected in star to a 400V 50 Hz 3-phase supply. Calculate the line current, the active power and power factor. If three capacitors each having same value are connected in delta to the same supply so as to form a parallel circuit with above coils calculate. (i)the capacitance to obtain the resultant power factor of 0.95 lagging. (ii)the line current taken by combined load. [2+3] Q6) A single phase 440V/110V transformer takes a no load current of 4A at 0.2 power factor. If the Secondary supplies a current of 100A at a power factor of 0.8 lagging. Determine (i)the current taken by primary winding. (ii)the magnetizing reactance and resistance representing core losses. [3+2] -------------------X-------------------- EEE-101/Mr.B.K.Verma, Mr.Gaurav Sharma, Ms.Kavya Mittal, Mr.Gaurav Singh, Mr. Anjanee kr. Mishra Date: 08/12/2012 Page-1

EEE-101/Mr.B.K.Verma, Mr.Gaurav Sharma, Ms.Kavya Mittal, Mr.Gaurav Singh, Mr. Anjanee kr. Mishra Date: 08/12/2012 Page-2

SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT B.Tech. [SEM I (CE,EC,EE,EN)] QUIZ TEST-4 (Session: 2012-13) Time: 1 Hour ELECTRICAL ENGINEERING Max. Marks: 30 (EEE-101) Roll No. Academic/26 Refer/WI/ACAD/18 Note: Attempt All Questions. (To be filled by the Student) Part A (Questions from Tutorial Sheet) [10 Marks] Q1) Derive emf equation of single phase transformer. A 25 KVA transformer has voltage ratio of 3300/400 volt, calculate primary and secondary currents. [Q-07] [3+1+1] Q2) An iron ring of cross sectional area 6 cm 2 is wound with wire of 100 turns and has a saw cut of 2mm. Calculate the magnetizing current required to produce flux of 0.1 m Wb, if mean length of magnetic path is 30 cm and relative permeability of iron is 470. [Q-06] [5] Part B [20 Marks] Q3) Short answer type question: (a) Write advantage of Grid in power system. [1] (b) Draw Torque V s Armature current characteristic for dc shunt motor. [1] (c) Write advantage of wound rotor over squirrel cage rotor. [1] (d) Why 3 phase induction motor also known as asynchronous motor? [1] (e) Why iron losses are known as constant losses? [1] Q4) A 3-phase delta connection 440V, 50Hz 4 pole induction motor has a rotor standstill emf per phase of 130V. If the motor speed is 1440rpm. Then calculate; (i) slip (ii) frequency of rotor induced emf (iii) rotor Induced emf per phase (iv) stator to rotor turn ratio. [2+1+1+1] Q5) Three coils having resistance of 20 ohm and inductive reactance of 15 ohm are connected in star to a 400V 50 Hz 3-phase supply. Calculate the line current, the active power and power factor. If three capacitors each having same value are connected in delta to the same supply so as to form a parallel circuit with above coils calculate. (i)the capacitance to obtain the resultant power factor of 0.95 lagging. (ii)the line current taken by combined load. [2+3] Q6) A single phase 440V/110V transformer takes a no load current of 4A at 0.2 power factor. If the Secondary supplies a current of 100A at a power factor of 0.8 lagging. Determine (i)the current taken by primary winding. (ii)the magnetizing reactance and resistance representing core losses. [3+2] -------------------X-------------------- EEE-101/Mr.B.K.Verma, Mr.Gaurav Sharma, Ms.Kavya Mittal, Mr.Gaurav Singh, Mr. Anjanee kr. Mishra Date: 08/12/2012 Page-1

SHRI RAMSWAROOP MEMORIAL COLLEGE OF ENGG. & MANAGEMENT B.Tech. [SEM I (CE,EC,EE,EN)] QUIZ TEST-4 (Session: 2012-13) Time: 1 Hour ELECTRICAL ENGINEERING Max. Marks: 30 (EEE-101) Roll No. Academic/26 Refer/WI/ACAD/18 Note: Attempt All Questions. (To be filled by the Student) Part A (Questions from Tutorial Sheet) [10 Marks] Q1) Explain the principle of operation and working of single phase transformer. Also write a note on various winding parameters used in it. [Q-05] [1+2+2] Q2) A coil is wound uniformly with 300 turns over a steel ring of relative permeability 900 having circumference of 40 cm and cross sectional area of 5 cm 2. If the coil has resistance of 100 ohms and is connected to 250 V dc supply, calculate (a) Coil m.m.f. (b)field strength (c)total flux (d)reluctance of the ring (e)permence of the ring [Q-15] [1+1+1+1+1] Part B [20 Marks] Q3) Short answer type question: (a) Write down the difference between core type and shell type transformer. [1] (b) Draw no load phasor diagram of ideal transformer. [1] (c) Write down the condition for maximum torque in 3 phase induction motor. [1] (d) Explain the term back emf. [1] (e) Which type of instrument is more accurate PMMC or MI? justify your answer. [1] Q4) A 3-phase delta connection 440V, 50Hz 4 pole induction motor has a rotor standstill emf per phase of 130V. If the motor speed is 1440rpm. Then calculate; (i) slip (ii) frequency of rotor induced emf (iii) rotor Induced emf per phase (iv) stator to rotor turn ratio. [2+1+1+1] Q5) Three coils having resistance of 20 ohm and inductive reactance of 15 ohm are connected in star to a 400V 50 Hz 3-phase supply. Calculate the line current, the active power and power factor. If three capacitors each having same value are connected in delta to the same supply so as to form a parallel circuit with above coils calculate. (i)the capacitance to obtain the resultant power factor of 0.95 lagging. (ii)the line current taken by combined load. [2+3] Q6) A single phase 440V/110V transformer takes a no load current of 4A at 0.2 power factor. If the Secondary supplies a current of 100A at a power factor of 0.8 lagging. Determine (i)the current taken by primary winding. (ii)the magnetizing reactance and resistance representing core losses. [3+2] -------------------X-------------------- EEE-101/Mr.B.K.Verma, Mr.Gaurav Sharma, Ms.Kavya Mittal, Mr.Gaurav Singh, Mr. Anjanee kr. Mishra Date: 08/12/2012 Page-1