VSD Series II Variable Speed Micro Drives (VSM II) FS1 FS5

Similar documents
safety Doc: DPD00714C, Released: vacon 1 ONLY A COMPETENT ELECTRICIAN IS ALLOWED TO CARRY OUT THE ELECTRICAL INSTALLATION! 1.

TECO F510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection

vacon 10 ac drives quick guide

M-Max series drives. The next generation of OEM drives

The GS1 Digital Keypad LED Display Function Keys Displaying the Status of the GS1 AC Drive Programming the GS1 AC Drive...

CHAPTER KEYPAD OPERATION AND QUICKSTART. In This Chapter... The GS2 Digital Keypad GS2 Quickstart...3 6

Honeywell. User Manual. SmartVFD COMPACT. Variable Frequency Drives for Constant and Variable Torque Applications

Document code: DPD00343A Edited:

vacon 100 flow ac drives application manual

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

D SERIES LM16. COMPACT DRIVE V/f and SLV CONTROL. LM16 COMPACT DRIVE V/f and SLV CONTROL

NX Series Inverters. HVAC Pocket Programming Guide

G+ Mini Transition Guide. Product Transition Guide P3 Series 2 to G+ Mini

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

S11 Adjustable Speed Drive Engineering Specification

TAC ATV38, IP55. Variable Speed Drives for Asynchronous Motors. 3-phase. 380/460 V, Hz

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3

NXL HVAC APPLICATION MANUAL Programming manual for NXL HVAC drives

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

SmartVFD HVAC2 APPLICATION MANUAL

VF-nC1 Adjustable Speed Drive Engineering Specification

MA7200 PLUS INVERTER SERIES PID Quick Start Manual For Fan and Pump Applications

CHAPTER AC DRIVE PARAMETERS. In This Chapter...

Comp-AC. User s Manual for type ACS 140 frequency converters from 0.12 to 2.2 kw

E3 Adjustable Speed Drive Engineering Specification

SV9000 SVReady USER MANUAL CONTENTS OPEN SV9000 USER MANUAL. SV9000 Page 0-1

INDEX. i 1. B Braking Resistor Dimensions: A 24 Braking Resistors: A 20 Braking Units: A 20. DURAPULSE AC Drive User Manual

L100-M Series Inverters

PowerFlex 400 Submittal

CHAPTER 3 WIRING DANGER

NX series Constant and variable torque Variable Speed Drives for induction motors

Installation & Operation Manual RSDA SERIES. ADjUSTAbLe FReqUenCy DRIveS FOR 3-PHASe AC MOTORS NEMA 4X /IP65

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE

This Chapter contains:

ADJUSTABLE SPEED DRIVES FS1

ACH550 HVAC Drive Submittal

GS1 Parameter Summary Detailed Parameter Listings...4 9

Fan and Pump AC Inverter

SJ100 Series Inverter Quick Reference Guide. Single-phase Input 200V Class Three-phase Input 200V Class Three-phase Input 400V Class

HITACHI. L100-M Series Inverter Quick Reference Guide. Hitachi Industrial Equipment Systems Co., Ltd. Single-phase Input 100V Class

General Purpose Drives

HPVFP High Performance Full Function Vector Frequency Inverter

Index 2. G Gain settings 4 31 Glossary of terms A 2 Grommets 2 13

1. Vacon Startup Startup Wizard PID Mini-Wizard Multi-pump mini-wizard... 5

smd frequency inverter

vacon nx all in one application manual ac drives Phone: Fax: Web: -

MagneTek. GPD 503 Technical Manual

A510 INVERTER. 230VClas3~ kW 1-3HP HP kW 1-425HP. 460VClas3~ 575/690VClas3~ 1-270HP INSTRUCTIONMANUAL

This operation manual is intended for users with basic knowledge of electricity and electric devices.

FUJI Inverter. Standard Specifications

Operating Instructions

Compact & Powerful Inverter STARVERT ig5a 0.4~1.5kW 1phase 200~230Volts 0.4~22kW 3Phase 200~230Volts 0.4~22kW 3Phase 380~480Volts

ig5a Compact AC Drive 0.4~1.5kW(0.5~2HP) 1-phase 200~230Volts 0.4~22kW(0.5~30HP) 3-Phase 200~230Volts 0.4~22kW(0.5~30HP) 3-Phase 380~480Volts

vacon nx ac drives all in one application manual

TOSVERT TM VF-nC3 Parameter List

Variable Speed Brushed DC Motor Drive

PowerFlex 400 AC Drive Guide Specification

ACS 100 AC Drives for Speed Control of. 1 / 6 to 3 Hp (0.18 to 2.2 kw) AC Induction Motors

vacon 100 flow ac drives application manual

Frequency inverters DF Vector frequency inverters DV

AF-300 G11 Specifications. GE Industrial Systems. Product Specifications AF-300 G11

Before you operate the inverter, the parameters that you must first program are the basic parameters.

FREQUENCY INVERTER VFR-013 QUICK START GUIDE

AF91 Adjustable Frequency Drives Series B

ig5a 0.4~1.5kW (0.5~2HP) 1phase 200~230Volts 0.4~22kW (0.5~30HP) 3Phase 200~230Volts 0.4~22kW (0.5~30HP) 3Phase 380~480Volts Compact & Powerful Drive

Inverter Drive /Vector Drive Motors & Controls

VFD - D700 Series Specifications. The latest low-cost variable speed control solution for centrifugal pumps.

user's manual nx frequency converters beam pump application asfiff13

Quick Reference Guide. DF5-... Frequency Inverters 02/02 AWB GB

Frequency Converters for Speed Control of 0.55 to 4.0 kw Squirrel Cage Motors Supply Voltage 208 to 240 V 380 to 480 V User s Manual

Users Manual SM5 INVERTER. Subject to changes without notice December, 2001

Installation and Operational Instructions for ROBA -switch Type 017._00.2

Power Supplies 3. SDN-C Compact DIN Rail Series

SAFETY INSTRUCTIONS WARNING

for Speed Control of 0.75 to 7.5 HP Induction Motors Supply Voltage 208 to 240 V 380 to 480 V Users Manual

Multi-purpose Control Application II

TECHNICAL DATASHEET #TDAX A DC MOTOR CONTROLLER P/N: AX Variable Speed Control, Onboard I/O CAN SAE J1939, Rugged Packaging

Addendum to the Operating Instructions

INSTALLATION AND USER MANUAL

Operating Instructions & Parts Manual. AC Motor Speed Control. Model 13E662 A40353

ATV212HU22M3X variable speed drive ATV kW - 3hp - 240V - 3ph - wo EMC - IP21

General Specifications FECA-TE /2010. Phone: Fax: Web:

Invertek Optidrive E3 Frequency Inverter (IP20, 3ph output) Easy Start Guide

KBE2 DIGITAL AC ADJUSTABLE SPEED DRIVES

CD-Pxx-00-0 Series Duct Mount CO 2 Transmitter

Variable Frequency Drives

AV-300i Specifications. Saftronics Inc. VG10 Product Specifications VG10. Dynamic Vector Drive

Max. sp Min. spe Negativ speed s Synchro out speed refere selection Menu 13. g t x (-1) UMV 4301

Variable frequency drives; 1-/3-phase 230 V; 10.5 A; 2.2 kw; EMC filters; braking transistor

CHAPTER MAINTENANCE AND TROUBLESHOOTING. In This Chapter... Maintenance and Inspection Troubleshooting...6 3

Vacon 100 Flow Course

KBDA SERIES STANDARD FEATURES DESCRIPTION PERFORMANCE FEATURES PROTECTION FEATURES

Safety Instructions WARNING. Do not remove the cover while power is applied or the unit is in operation.

Manual Overview...1 2

VS1SM Single Phase AC Drive

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

Comp-AC. User s Manual for type ACS 100 frequency converters from 0.12 to 2.2 kw

vacon 100 ac drives application manual

Transcription:

New Information Electric Current! Danger to Life! Only skilled or instructed persons may carry out the following operations. Variable Speed Micro Drives for Machinery Applications () VSxxx0_, VSxxx2x4_, VSxxx2x3_, VSxxx4_, VSxxx5_ BACK RESET OK LOC REM I LIT-12011835 User Manual Please visit www.johnsoncontrols.com R HVAC sales R Variable Speed Drives or scan the QR code to download or view the complete user manual. JOHNSON CONTROLS www.johnsoncontrols.com 1

Dimensions and Weights a a1 a a1 a a1 0.28 in (7 mm) b1 b b1 b b1 b b1 b FS1 FS2 FS3 a a1 Ø 0.28 (7.0) b1 b2 b2 c Ø1 Ø2 a1 FS4 FS5 c 2 JOHNSON CONTROLS www.johnsoncontrols.com

Instruction Leaflet LIT-12011836 Dimensions and Frame Sizes Note 1 in = 25.4 mm, 1 mm = 0.0394 in Approximate Dimensions in inches (mm) Part Number a a1 b b1 b2 c Ø, Ø1 Ø2 VS1D7204B-M_ VS2D4204B-M_ VS2D8204B-M_ VS1D7203B-M_ VS2D4203B-M_ VS2D8203B-M_ VS1D3403B-M_ VS1D9403B-M_ VS2D4403B-M_ VS1D7004B-M_ VS2D4004B-M_ VS2D8004B-M_ VS3D7004B-M_ 2.60 (66) 3.54 (90) VS3D7204B-M_ VS4D8204B-M_ VS7D0204B-M_ VS3D7203B-M_ VS4D8203B-M_ VS7D0203B-M_ VS3D3403B-M_ VS4D3403B-M_ VS5D6403B-M_ VS4D8004B-M_ 3.94 (100) VS9D6204B-M_ VS011203B-M_ VS7D6403B-M_ VS9D0403B-M_ VS012403B-M_ VS014403B-M_ VS1D7503B-M_ VS2D7503B-M_ VS3D9503B-M_ VS6D1503B-M_ VS9D0503B-M_ VS017203B-M_ VS025203B-M_ VS016403B-M_ VS023403B-M_ VS031203B-M_ VS038203B-M_ VS031403B-M_ VS038403B-M_ 6.50 (165.0) 6.50 (165.0) 1.50 (38) 2.46 (62.5) 2.95 (75) 5.51 (140.0) 5.51 (140.0) 6.30 (160) 7.68 (195) 9.96 (253) 14.57 (370.0) 14.57 (414.0) 5.79 (147) 7.17 (182) 9.53 (242) 13.82 (351.0) 13.82 (398.0) 1.26 (32) 1.26 (32) 1.34 (34) 13.27 (337.0) 15.08 (383.0) 4.02 (102) 4.14 (105) 4.41 (112) 6.61 (168.0) 8.07 (205.0) 0.18 (4.5) 2.17 (5.5) 2.17 (5.5) 0.28 (7.0) 0.28 (7.0) FS1 FS2 FS3 0.55 (14.0) 0.55 (14.0) Installation Size FS4 FS5 JOHNSON CONTROLS www.johnsoncontrols.com 3

Mounting a1 = M4 = M4 b1 0.28 in (7 mm) a1 mm [in] b1 mm [in] Mass kg [lb] Torque Nm [ft-lb] FS1 38 [1.5] 147 [5.79] 0.55 [1.2] 1.3 [0.95] M4 FS2 62.5 [2.46] 182 [7.17] 0.7 [1.5] 1.3 [0.95] M4 Mounting Screw 1.3 Nm (11.5 lb-in) FS1, FS2 FS3 FS5 1.3 Nm (11.5 lb-in) FS3 75 [2.95] 242 [9.53] 0.99 [2.2] 1.3 [0.95] M5 FS4 140 [5.51] 351 [13.82] 8 [18.0] 4.6 [3.4] M6 FS5 140 [5.51] 398 [13.82] 10 [22.0] 4.6 [3.4] M6 Mounting Positions 30 30 30 30 90 90 90 90 FS1 FS3 FS4, FS5 4 JOHNSON CONTROLS www.johnsoncontrols.com

Instruction Leaflet LIT-12011836 Air-Cooling Space c Minimum Clearance at the Front V a b a a (b) e d Minimum Clearance and Required Cooling Air a mm b mm c mm d mm e mm FS1 20 50 100 50 15 10 FS2 20 50 100 50 15 10 FS3 20 50 100 50 15 30 FS4 20 50 100 100 20 45 FS5 20 50 120 100 20 75 V m 3 /h V Mounting Positions 25.0 35.0 0.98 1.38 IEC/EN 60715 [mm] 1.0 7.5 15.0 [inch] 0.04 0.29 0.59 5.0 0.197" 2 JOHNSON CONTROLS www.johnsoncontrols.com 5

Warning! Connect only in voltage-free state! PZ2 1.3 Nm (11.5 lb-in) Connection to Power Section VSxxx0_ VSxxx2x4_ VSxxx2x3_, VSxxx4_, VSxxx5_ Input L2/N L3 Input L1 Input L2/N L3 Output U1 V1 W1 3 ~ Motor PE L1 N PE L1 N PE L1 L2 L3 Connection in Power Section PE L1 L2 L3 PE U V W DC+ DC PE R+ R A1 C1 A2 C2 B1 D1 B2 D2 Stripping Lengths in the Power Section in inches (mm) Supply Voltage (Input) Motor (Output) DC-Link, Brake Resistor L1, L2, L3 PE U/T1, V/T2, W/T3 PE DC+/R+, R, DC PE C1 D1 A1 B1 C1 D1 A1 B1 C2 D2 A2 B2 FS1 0.30 (8.0) 0.80 (20.0) 0.30 (8.0) 1.40 (35.0) 0.30 (8.0) 0.80 (20.0) 0.30 (8.0) 1.40 (35.0) 0.30 (8.0) 0.80 (20.0) 0.30 (8.0) 1.40 (35.0) FS2 0.30 (8.0) 0.80 (20.0) 0.30 (8.0) 1.40 (35.0) 0.30 (8.0) 0.80 (20.0) 0.30 (8.0) 1.40 (35.0) 0.30 (8.0) 0.80 (20.0) 0.30 (8.0) 1.40 (35.0) FS3 0.30 (8.0) 0.80 (20.0) 0.30 (8.0) 1.40 (35.0) 0.30 (8.0) 0.80 (20.0) 0.30 (8.0) 1.40 (35.0) 0.30 (8.0) 0.80 (20.0) 0.30 (8.0) 1.40 (35.0) FS4 0.30 (8.0) 1.60 (40.0) 0.30 (8.0) 1.20 (30.0) 0.30 (8.0) 2.00 (50.0) 0.30 (8.0) 1.20 (30.0) 0.30 (8.0) 1.60 (40.0) 0.30 (8.0) 1.60 (40.0) FS5 0.30 (8.0) 1.60 (40.0) 0.30 (8.0) 1.20 (30.0) 0.30 (8.0) 2.00 (50.0) 0.30 (8.0) 1.20 (30.0) 0.30 (8.0) 2.00 (50.0) 0.30 (8.0) 2.00 (50.0) 6 JOHNSON CONTROLS www.johnsoncontrols.com

Instruction Leaflet LIT-12011836 Arrangement and Size of the Connection Terminals PZ2 Part M3 Numbers Nm ft-lbs mm Terminal Configuration FS1 VS1D7204B-M_ VS2D4204B-M_ VS2D8204B-M_ VS1D7203B-M_ VS2D4203B-M_ VS2D8203B-M_ L3 U/T1V/T2W/T3 PE M4 11.5 lb-in (1.3 Nm) VS1D3403B-M_ VS1D9403B-M_ VS2D4403B-M_ L3 U/T1V/T2W/T3 FS2 VS1D7004B-M_ VS2D4004B-M_ VS2D8004B-M_ VS3D7004B-M_ L2/N L3 0.17 in (4.3 mm) VS3D7204B-M_ VS4D8204B-M_ VS7D0204B-M_ VS3D7203B-M_ VS4D8203B-M_ VS7D0203B-M_ L3 R+ R VS3D3403B-M_ VS4D3403B-M_ VS5D6403B-M_ L3 R+ R FS3 VS4D8004B-M_ L2/N L3 VS9D6204B-M_ VS011203B-M_ L3 R+ R VS7D6403B-M_ VS9D0403B-M_ VS012403B-M_ VS014403B-M_ L3 R+ R VS1D7503B-M_ VS2D7503B-M_ VS3D9503B-M_ VS6D1503B-M_ VS9D0503B-M_ L3 R+ R FS4 VS017203B-M_ VS025203B-M_ 1.2 1.5 0.88 1.11 0.6 x 3.5 L1 L2 L3 DC+/R+ R- DC- VS016403B-M_ VS023403B-M_ 1.2 1.5 0.88 1.11 0.6 x 3.5 L1 L2 L3 DC+/R+ R- DC- FS5 VS031203B-M_ VS038203B-M_ 1.2 1.5 0.88 1.11 0.6 x 3.5 L1 L2 L3 DC+/R+ R- DC- VS031403B-M_ VS038403B-M_ 1.2 1.5 0.88 1.11 0.6 x 3.5 L1 L2 L3 DC+/R+ R- DC- JOHNSON CONTROLS www.johnsoncontrols.com 7

Maximum Cross-Sections L1, L2/N, L3 U, V, W PE R+, R mm 2 AWG 1 mm 2 AWG 1 mm 2 AWG 1 mm 2 AWG 1 VS1D7004B-M VS2D4004B-M VS2D8004B-M VS3D7004B-M 2 x 2.5 2 x 14 3 x 2.5 3 x 14 2.5 14 VS4D8004B-M 2 x 6 2 x 10 3 x 6 3 x 10 VS1D7204B-M VS2D4204B-M VS2D8204B-M VS3D7204B-M VS4D8204B-M VS7D0204B-M 2 x 1.5 2 x 16 3 x 1.5 3 x 16 1.5 16 2 x 2.5 2 x 14 3 x 2.5 3 x 14 2.5 14 VS9D6204B-M 2 x 6 2 x 10 3 x 6 3 x 10 6 10 VS1D7203B-M VS2D4203B-M VS2D8203B-M VS3D7203B-M VS4D8203B-M VS7D0203B-M 3 x 1.5 3 x 16 3 x 1.5 3 x 16 1.5 16 3 x 1.5 3 x 16 3 x 1.5 3 x 16 1.5 16 VS011203B-M 3 x 2.5 3 x 14 3 x 2.5 3 x 14 2.5 14 2 x 2.5 2 x 14 VS017203B-M VS025203B-M VS031203B-M VS038203B-M 3 x 6 3 x 10 3 x 6 3 x 10 6 10 2 x 6 2 x 10 3 x 10 3 x 8 3 x 8 3 x 8 10 8 2 x 10 2 x 8 VS1D3403B-M VS1D9403B-M VS2D4403B-M VS3D3403B-M VS4D3403B-M VS5D6403B-M VS7D6403B-M VS9D0403B-M VS012403B-M Notes 1 AWG = American Wire Gauge. 2 UL fuse with AWG. 3 x 1.5 3 x 16 3 x 1.5 3 x 16 1.5 16 3 x 1.5 3 x 16 3 x 1.5 3 x 16 1.5 16 2 x 1.5 2 x 16 3 x 2.5 3 x 14 3 x 2.5 3 x 14 2.5 14 2 x 2.5 2 x 14 VS014403B-M 3 x 4 3 x 12 3 x 12 3 x 12 4 12 3 x 4 2 x 12 VS016403B-M 3 x 6 3 x 10 3 x 6 3 x 10 6 10 2 x 6 2 x 10 VS023403B-M VS031403B-M 3 x 10 3 x 8 3 x 8 3 x 8 10 8 2 x 10 2 x 8 VS038403B-M 3 x 10 3 x 6 3 x 8 3 x 6 10 6 2 x 10 2 x 6 VS1D7503B-M 3 x 1.5 3 x 16 3 x 1.5 3 x 16 1.5 16 2 x 1.5 2 x 16 VS2D7503B-M VS3D9503B-M VS6D1503B-M VS9D0503B-M 3 x 2.5 3 x 14 3 x 2.5 3 x 14 2.5 14 2 x 2.5 2 x 14 2 x 1.5 2 x 16 8 JOHNSON CONTROLS www.johnsoncontrols.com

Instruction Leaflet LIT-12011836 JOHNSON CONTROLS www.johnsoncontrols.com 9

AI2 GND DO- DI4 DI5 DI6 AO DO+ R13 R14 - R24 4 5 13 14 15 16 18 20 22 23 26 1 2 3 6 7 8 9 10 25 24 + 10V AI1 GND 24V DI-C DI1 DI2 DI3 A B R21 R22 M3 mm 2 mm 2 AWG mm Nm ft-lbs mm 0.25 0.5 0.14 1.5 26 16 5 0.22 0.25 0.16 0.18 0.4 x 2.5 Microswitch Factory Settings AI2 GND DO DI4 DI5 DI6 AO DO+ R13 R14 R24 4 5 13 14 15 16 18 20 22 23 26 1 2 3 6 7 8 9 10 25 24 +10V AI1 GND 24V DI-C DI1 DI2 DI3 A B R21 R22 LOGIC + AI 1 V ma AI 2 V ma RS 485 Term. S4 = RS485 ( ) S3 = AI2 (ma) S2 = AI1 (V) Microswitch Description S1 LOGIC Control logic: + = Positive logic (FS) Source type = Negative logic Sink type S2 AI1 Analog input 1 (P2.1): V = 0 10V (FS) ma=4 20mA S3 AI2 Analog input 2 (P2.5): ma=4 20mA (FS) V=0 10V S4 RS485 Bus terminating resistor (control signal terminal A/B): = Disconnected Term. = Switched on (terminator) S1 = LOGIC (+) L3 U/T1 V/T2W/T3 15 mm [0.59 in] PES 10 JOHNSON CONTROLS www.johnsoncontrols.com

Instruction Leaflet LIT-12011836 Factory-Set Control Terminal Functions Terminal Signal Factory setting Description 1 +10V Output nominal voltage Maximum load 10 ma, reference potential GND 2 AI1 Analog signal input 1 Frequency reference value 1 0 10V (R i >200k ohms) 0/4 20 ma (R B = 200 ohms) Selectable through microswitch S2 3 GND Reference potential 0V 4 AI2 Analog input 2 PID controller, actual value 1 0 10V (R i >200k ohms) 0/4 20 ma (R B = 200 ohms) Selectable through microswitch S3 5 GND Reference potential 0V 6 24V Control voltage for DI1 DI6, output (+24V) Maximum load 50 ma, reference potential GND 7 DI-C Reference potential of the digital inputs DI1 DI6 LOGIC- (GND) Selectable through microswitch LOGIC /+ 8 DI1 Digital input 1 FWD start enable, forward 1 0 30V (R i >12k ohms) 9 DI2 Digital input 2 REV start enable, reverse 1 0 30V (R i >12k ohms) 10 DI3 Digital input 3 Fixed frequency B0 1 0 30V (R i >12k ohms) 13 DO Digital output Active = READY 1 Transistor, max. 50 ma, supply voltage control signal terminal 20 14 DI4 Digital input 4 Fixed frequency B1 1 0 30V (R i = 12k ohms) 15 DI5 Digital input 5 Error acknowledgment 1 0 30V (R i = 12k ohms) 16 DI6 Digital input 6 PI controller deactivated 1 0 30V (R i = 12k ohms) 18 AO Analog output Output frequency 1 0 10V, max. 10 ma 20 DO+ Digital output Supply voltage, see control signal terminal 13 Supply voltage for digital output DO max. 48 Vdc, max. 50 ma 22 R13 Relay 1, normally open contact Active = 1 Maximum switching load: 250 Vac/2A or 250 Vdc/0.4A 23 R14 Relay 1, normally open contact Active = 1 Maximum switching load: 250 Vac/2A or 250 Vdc/0.4A 24 R22 Relay 2, changeover contact (N/C) Active = FAULT 1 Maximum switching load: 250 Vac/2A or 250 Vdc/0.4A 25 R21 Relay 2, changeover contact Active = FAULT 1 Maximum switching load: 250 Vac/2A or 250 Vdc/0.4A 26 R24 Relay 2, changeover contact (N/O) Active = FAULT 1 Maximum switching load: 250 Vac/2A or 250 Vdc/0.4A A A RS485 signal A BUS-communication Modbus RTU B B RS485 signal B BUS-communication Modbus RTU Note 1 Programmable function, see User Manual MN04020003E. S1 120 Ω S1 120 Ω S1 120 Ω A B A B A B 2 n Host Computer A-B: 120 Ω A-B: 120 Ω A-B: 120 Ω S1 OFF S1 OFF S1 ON JOHNSON CONTROLS www.johnsoncontrols.com 11

Caution! In the territory of the EU Directive, the frequency-controlled devices and their accessories must be taken into operation only when the machine has been determined to fulfill the protection requirements of Machinery Safety Directive 89/392/EEC. Ensure EMC-compliant installation. Lay control and communication cables spatially separated from the motor cable. Ensure a large contact area connection between p cable screen and PE. VSxxx0, VSxxx2x4 1 AC 120V 24V FWD REV FF1 FF2 Reset PI-Off L2/N L3 PE 6 <50 ma +24V Out 7 8 9 DI_COM DI1 DI2 DI3 10 14 15 16 DI4 DI5 DI6 120 ohms S4 X1 A S1 B 200k ohms 200k ohms U V W PE R13 22 R14 R21 23 Run R22 R24 25 24 26 3 1 2 5 4 Error GND +10 V Out < 10 ma f-soll AI1 0 10V 200 ohms S2 GND S3 200 ohms AI2 PI-Ist 0 (4) 20 ma f-out AO 0 10V <10 ma 18 DO <50 ma Ready DO+ 13 20 + M 3 ~ 3 AC 230V VSxxx2x3, VSxxx4, VSxxx5 3 AC 24 V FWD REV FF1 FF2 L1 L3 PE 6 7 8 9 10 14 15 16 120 Ω < 50 ma +24 V Out DI_COM DI1 DI2 Reset DI3 PI-Off L2/N DI4 DI5 DI6 S4 X1 A EMC S1 B R+ R- 200 kω 200 kω 200 Ω S2 S3 200 Ω PE U V W PE R13 R14 22 23 Run R21 R22 R24 25 24 26 3 1 2 5 4 Error GND +10 V Out < 10 ma f-soll AI1 0...+10 V GND AI2 P I-Ist 0 (4)...20 ma AO f-out 18 0...+10 V < 10 ma DO- < 50 ma Ready DO+ 13 20 + M 3 ~ 3 AC VS4D3403B-M, VS5D6403B-M, VS7D6403B-M, VS9D0403B-M, VS012403B-M, VS014403B-M 12 JOHNSON CONTROLS www.johnsoncontrols.com

Instruction Leaflet LIT-12011836 READY STOP ALARM FAULT REF MON PAR FLT Self test, Setup FWD REV I/O KEYPAD BUS READY STOP ALARM FAULT READY STOP ALARM FAULT REF MON PAR FLT REF MON PAR FLT FWD REV I/O KEYPAD BUS FWD REV I/O KEYPAD BUS Ready to start Start (Stop): FWD/REV R11 = Frequency set value Stop + 10V AI1 GND 24V DI1 DI2 READY STOP ALARM FAULT REF MON PAR R11 FWD REV FLT FWD REV I/O KEYPAD BUS READY STOP ALARM FAULT REF MON PAR FLT FWD REV I/O KEYPAD BUS REF MON PAR FLT READY STOP ALARM FAULT FWD REV I/O KEYPAD BUS READY STOP ALARM FAULT Frequency set value REF MON PAR Frequency set value FLT FWD REV I/O KEYPAD BUS I Start Stop 0 Hz 2 x OK Set/Save Note: On startup for the first time, the VSM II will enter a Startup Wizard and will prompt the user to set a few critical parameters. JOHNSON CONTROLS www.johnsoncontrols.com 13

UL Cautions, Warnings, and Instructions Wiring Warnings for Electrical Practices and Wire Sizes The cautions, warnings, and instructions in this section summarize the procedures necessary to ensure an inverter installation complies with Underwriters Laboratories guidelines. Warning! Use 60/75 C Cu wire only or equivalent. Warning! Open Type Equipment. Warning! Suitable for use on a circuit capable of delivering not more than 5,000 rms symmetrical amperes: 120V maximum for VSxxx0 models. 240V maximum for VSxxx2x4 and VSxxx2x3 models. 480V maximum for VSxxx4 models. 575V maximum for VSxxx5 models. Circuit Breaker and Fuse Sizes The adjustable frequency drive s connections to input power must include UL Listed inverse time circuit breakers with 600V rating, or UL Listed fuses. Terminal Tightening Torque and Wire Size The wire size range and tightening torque for field wiring terminals are presented. Wire Connectors Cable Cable Warning! Field wiring connections must be made by a UL Listed and CSA Certified ring lug terminal connector sized for the wire gauge being used. The connector must be fixed using the crimping tool specified by the connector manufacturer. Motor Overload Protection Cable Cable support Terminal (ring lug) VSM II adjustable frequency drives provide solid-state motor overload protection, which depends on the proper setting of the following parameter: P7.2 current limit. Set the rated current [Amperes] of the motor(s) with the above parameters. The setting range is 0.2 * rated current to 2 * rated current, R manual LIT-12011835. PE Warning! When two or more motors are connected to the inverter, they cannot be protected by the electronic overload protection. Install an external thermal relay on each motor. 14 JOHNSON CONTROLS www.johnsoncontrols.com

Instruction Leaflet LIT-12011836 Specified Fuses and Disconnect Devices Maximum Permitted Line Supply Voltage Part No. VSM II U LN [V] VDE [A] UL [A] 1 Type Designation Type Designation/Catalog No. VS1D7004B-M 1 AC 120V +10% 20 20 FAZ-B20/1N VS2D4004B-M 1 AC 120V +10% 20 20 FAZ-B20/1N VS2D8004B-M 1 AC 120V +10% 20 20 FAZ-B20/1N VS3D7004B-M 1 AC 120V +10% 20 20 FAZ-B20/1N VS4D8004B-M 1 AC 120V +10% 32 30 FAZ-B32/1N VS1D7204B-M 1 AC 240V +10% 10 10 FAZ-B10/1N VS2D4204B-M 1 AC 240V +10% 10 10 FAZ-B10/1N VS2D8204B-M 1 AC 240V +10% 10 10 FAZ-B10/1N VS3D7204B-M 1 AC 240V +10% 10 10 FAZ-B101/N VS4D8204B-M 1 AC 240V +10% 20 20 FAZ-B20/1N VS7D0204B-M 1 AC 240V +10% 20 20 FAZ-B20/1N VS9D6204B-M 1 AC 240V +10% 32 30 FAZ-B32/1N VS1D7203B-M 3 AC 240V +10% 6 6 FAZ-B6/3 PKM0-6.3/XTPM6P3BNL VS2D4203B-M 3 AC 240V +10% 6 6 FAZ-B6/3 PKM0-6.3/XTPM6P3BNL VS2D8203B-M 3 AC 240V +10% 6 6 FAZ-B6/3 PKM0-6.3/XTPM6P3BNL VS3D7203B-M 3 AC 240V +10% 6 6 FAZ-B6/3 PKM0-6.3/XTPM6P3BNL VS4D8203B-M 3 AC 240V +10% 10 10 FAZ-B10/3 PKM0-10/XTPM010BNL VS7D0203B-M 3 AC 240V +10% 10 10 FAZ-B10/3 PKM0-10/XTPM010BNL VS011203B-M 3 AC 240V +10% 20 20 FAZ-B20/3 PKM0-20/XTPM020BNL VS017203B-M 3 AC 240V +10% 25 25 FAZ-B25/3 PKM0-25/XTPM025BNL VS025203B-M 3 AC 240V +10% 32 40 FAZ-B32/3 PKM0-32/XTPM032BNL VS031203B-M 3 AC 240V +10% 40 40 FAZ-B40/3 PKM4-40/XTPM040BNL VS038203B-M 3 AC 240V +10% 50 50 FAZ-B50/3 PKM4-50/XTPM050BNL VS1D3403B-M 3 AC 480V +10% 6 6 FAZ-B6/3 PKM0-6.3/XTPM6P3BNL VS1D9403B-M 3 AC 480V +10% 6 6 FAZ-B6/3 PKM0-6.3/XTPM6P3BNL VS2D4403B-M 3 AC 480V +10% 6 6 FAZ-B6/3 PKM0-6.3/XTPM6P3BNL VS3D3403B-M 3 AC 480V +10% 6 6 FAZ-B6/3 PKM0-6.3/XTPM6P3BNL VS4D3403B-M 3 AC 480V +10% 10 10 FAZ-B10/3 PKM0-10/XTPM010BNL VS5D6403B-M 3 AC 480V +10% 10 10 FAZ-B10/3 PKM0-10/XTPM010BNL VS7D6403B-M 3 AC 480V +10% 20 20 FAZ-B20/3 PKM0-20/XTPM020BNL VS9D0403B-M 3 AC 480V +10% 20 20 FAZ-B20/3 PKM0-20/XTPM020BNL VS012403B-M 3 AC 480V +10% 20 20 FAZ-B20/3 PKM0-20/XTPM020BNL VS014403B-M 3 AC 480V +10% 25 25 FAZ-B25/3 PKM0-25/XTPM025BNL VS016403B-M 3 AC 480V +10% 25 25 FAZ-B25/3 PKM0-25/XTPM025BNL VS023403B-M 3 AC 480V +10% 32 40 FAZ-B32/3 PKM0-32/XTPM032BNL VS031403B-M 3 AC 480V +10% 40 40 FAZ-B40/3 PKM4-40/XTPM040BNL VS038403B-M 3 AC 480V +10% 50 50 FAZ-B50/3 PKM4-50/XTPM050BNL VS1D7503B-M 3 AC 575V +10% 6 6 FAZ-B6/3 PKM0-6.3/XTPM6P3BNL VS2D7503B-M 3 AC 575V +10% 6 6 FAZ-B6/3 PKM0-6.3/XTPM6P3BNL VS3D9503B-M 3 AC 575V +10% 6 6 FAZ-B6/3 PKM0-6.3/XTPM6P3BNL VS6D1503B-M 3 AC 575V +10% 10 10 FAZ-B10/3 PKM0-10/XTPM010BNL VS9D0503B-M 3 AC 575V +10% 20 20 FAZ-B20/3 PKM0-20/XTPM020BNL Notes 1 Fuse UL-rated, Class J, 600V. 2 I cn 10 ka. 2 2 JOHNSON CONTROLS www.johnsoncontrols.com 15

Quick Start Parameter Guide Predefined Application Parameters from Parameter P1.2 Parameter (PNU) Basic (Standard Drive) Pump Drive Fan Drive High Load Designation P1.1 1 = Only quick configuration parameters 1 = Only quick configuration parameters 1 = Only quick configuration parameters 1 = Only quick configuration parameters Quick start parameters P1.2 0 = Basic 1 = Pump drive 2 = Fan drive 3 = Hoisting device (high load) Application P1.3 1 = N/A 1 = N/A 1 = N/A 1 = N/A Country specific default settings P6.1 1 = Control signal terminals (I/O) (I/O) 1 = Control signal terminals (I/O) (I/O) 1 = Control signal terminals (I/O) (I/O) 1 = Control signal terminals (I/O) (I/O) Primary remote control source P6.2 3 = AI1 (analog setpoint 1) 3 = AI1 (analog setpoint 1) 3 = AI1 (analog setpoint 1) 3 = AI1 (analog setpoint 1) Primary remote speed reference P6.3 00.00 Hz 20.00 Hz 20.00 Hz 00.00 Hz Minimum frequency P6.4 60.00 Hz 60.00 Hz 60.00 Hz 60.00 Hz Maximum frequency P6.5 3.0s 5.0s 20.0s 1.0s Acceleration time (acc1) P6.6 3.0s 5.0s 20.0s 1.0s Deceleration time (dec1) P6.7 0 = Ramp (acceleration) 0 = Ramp (acceleration) 0 = Ramp (acceleration) 0 = Ramp (acceleration) Start function P6.8 0 = Free coasting 1 = Deceleration time (ramp) 0 = Free coasting 0 = Free coasting Stop function P7.1 I e I e I e I e Motor, rated current P7.3 1720 RPM 1720 RPM 1720 RPM 1720 RPM Motor, rated speed (RPM) P7.4 0.85 0.85 0.85 0.85 Motor, power factor (cos w) P7.5 230/460/575V 230/460/575V 230/460/575V 230/460/575V Motor, rated operating voltage P7.6 60 Hz 60 Hz 60 Hz 60 Hz Motor, rated frequency P11.7 0 = Deactivated 0 = Deactivated 0 = Deactivated 1 = Enabled Torque increase M1.1 0.00 Hz 0.00 Hz 0.00 Hz 0.00 Hz Output frequency (display only) Controls Group 507 E. Michigan Street P.O. Box 423 Milwaukee, WI 53201 Powered by Eaton Technology 2013 Johnson Controls All Rights Reserved Printed in USA Publication No. LIT-12011836 / Z13717 May 2013