onlinecomponents.com

Similar documents
Relays & Sockets RY/RM RY/RM Series Miniature Relays. Part Number Selection

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

Timers GE1A. GE1A Series ON Delay Timers Single Function

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

Analog Universal Module HART for Zone 2 Series 9468/33

6mm Interface Relays RV8 Series

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series

Relays & Sockets. RH Series Compact Power Relays. Part Number Selection. Blade Terminal

GT5Y Series ON Delay Timers. UL, c-ul Listed File No. E V AC, 3A 30V DC, 3A 220V AC, 0.8A 30V DC, 1.5A 660VA AC 90W DC 176VA AC 45W DC

Temperature Input Module for Zone 1 Series 9482/32

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Digital Input Output Module for Zone 2 Series 9470/33

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

RJ Series Slim Power Relays

Isolators A3/1. Vibration Transducer Supply Unit Series

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

Relays & Sockets. RF2V 2-Pole Force Guided Relays/SJ Series Relay Sockets. UL/Recogntion File No. E55996 TÜV SÜD. EU Low Voltage Directive

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range

22 Series Relays. Technical Data...1. Specifications...2. Model Number Structure - Relays...3. Model Number Selection

Binary Output Series 9175

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Digital Input Output Module for Zone 1 Series 9470/32

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Binary Output without Power Supply Series 9176

IDEC RJ22 Series Slim Power Relays (Bifurcated Contacts)

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Single-Channel Safety Barriers Series 9001

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

MACX MCR-EX-T-UI-UP. Extract from the online catalog. Order No.:

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

HG RELAYS 20 AMP POWER RELAY FEATURES SPECIFICATIONS

Digital Input Output Module for Zone 2 Series 9470/33

MODEL: B3HU. Space-saving Two-wire Signal Conditioners B3-UNIT

Isolating Repeater Input Series 9163

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

3 Ex i Isolators. Temperature Transmitter with Output 0/ ma, without Limit Value Contact (Field Circuit Ex i) Type 9182/.0-5.

SINEAX TI 807 Passive DC signal isolator

RU Series Universal Relays

20 AMP POWER RELAY HG RELAYS. a HG HG HG Unit weight. Ex. HG 2 AC 240 V

RMA42. Technical Information

58 SERIES. Relay interface modules 7-10 A 58.P3 58.P4

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Classification Contact form Enclosure rating Terminal shapes Model Minimum packing unit Standard. SPST-NO (1a) Fully sealed PCB terminal

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range 13.

GT3W Series Dual Time Range Timers. CSA Certified File No.LR58183 LR96764 LR83814

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

MINI MCR-SL-UI-I-LP-NC

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

IP26 Series Current to Pneumatic Converter

SINEAX B 811 Power Pack with additional Functions

Isolators A3/1.

12 V DC ±10 % 150 ma max. 130 ma max. 120 ma max.

RU Series. Full featured universal miniature relays. Designed with environment taken into consideration.

Zelio Control Measurement Relays

UNIQUELY DESIGNED RELAY WITH HIGH SENSITIVITY. UL File No.: E43149 CSA File No.: LR26550

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Select G3PA SSRs and G32A Cartridges to be Discontinued; Replace with G3PA-X or G3PJ Relays, G32A-A-X Cartridges

Model Number Structure

OMRON MK-I / -S RELAY

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

Power PCB Relay. To Order: Select the part number and add the desired coil voltage rating (e.g., G6B-1114-US-DC6).

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

Relays & Sockets. Switching & Controls.

Slim type safety relays. FEATURES 1. Acquisition of Korean safety certification ( S mark) Excluding with diode type

Temperature transmitter itemp RTD DIN rail TMT 127

G6C. Miniature High Capacity Relays with SPST-NO 10A and SPST-NO + SPST-NC 8A. Model Number Legend. Application Examples.

MY-GS. Miniature Power Relays. Mechanical Indicators Added as a Standard Feature to Our Bestselling MY General-purpose Relays.

PARM-SIZED, 16-CHANNEL RELAY TERMINALS

27/04/2015

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

Weighing Instruments

Intrinsically Safe Pressure Transmitter for highest pressure applications in hazardous environments Model IS-20-H

FP-DO-403 and cfp-do-403

Isolated Intrinsic Safety Barrier

Relays. Switching & Controls. Selection Guide

GENERAL PURPOSE RELAYS

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

This document provided by Barr-Thorp Electric Co., Inc

MODEL: B6U-B B6-UNIT. [2] LCD DISPLAY 0: Without 1: With

Weighing Instruments. Applications. Characteristics. DMS strain gauges (load cells), DMS amplifier

Two-channel safety barriers Series 9002

FP-DO-401 and cfp-do-401

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

D1035S INSTRUCTION MANUAL. Frequency-Pulse Isolating Repeater DIN Rail Model D1035S. D Frequency-Pulse Isolating Repeater

NI Channel SPST Electromechanical Relay Module

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation

Relays. Switching & Controls. Selection Guide

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Fieldbus Isolating Repeater Series 9185/11

MODEL: M2SES SEN TRONIC AG [3] OUTPUT

CompactLogix 5370 L3 Control System

Transcription:

Key features: Relay Barrier: Intrinsically Safe Explosion-Proof: EB3C Relay [Exia] II C IEC0079 compliant Dry-contact switches can be connected to the EB3C 8- and 1-circuit types are available in common wiring types, ideal for connection to (DC voltage only) Universal AC power voltage (0 to 240V AC) or power (UL rating: 0 120V AC) No grounding required IDEC s original spring-up terminals minimizes wiring time Installation: 35-mm-wide DIN rail mounting or direct panel mounting Global usage USA: UL/FM Canada: CSA Europe: CE marking, ATEX China: CQST Russia: GOST-R Japan: TIIS Korea: KOSHA Ship class: NK (Japan), KR (Korea) Dry Contact Switches Dry-contact switches can be connected to the EB3C. LB Series CW Series HW Series LISTED FM APPROVED Common Wiring for PLC Inputs 8- and 1-circuit types are available in common wiring types, ideal for connection to (DC voltage only). Connector Type MIL connector on the non-hazardous side Easy connection to Wiring is cut by 90% (compared with IDEC s 1-circuit EB3C) Various 20-pin MIL connectors can be connected Spring-up Fingersafe Terminals Reduce Wiring Time Finger-safe 224 www.idec.com

EB3C Relay Power Voltage 0 to 240V AC (UL rating: 0 120V AC) Number of Channels *Note: These models are NOT Listed by UL Connection to Non-intrinsically Safe Circuit Part Numbers Input Wiring Method Output Part Number 1 EB3C-R01A 2 EB3C-R02A 3 EB3C-R03A 5 Separate/Common Wiring Compatible EB3C-R05A Relay EB3C-R0A 8 EB3C-R08A EB3C-RA 8 Common Wiring Only EB3C-R08CA EB3C-T0A 8 Separate/Common Wiring Compatible Transistor (Sink/Source) EB3C-T08A Screw Terminal EB3C-TA 1 Common Wiring Only Transistor (Sink) EB3C-T1CKA 8 Common Wiring Only EB3C-R08CD Separate/Common Wiring Compatible Relay EB3C-RD 1 Common Wiring Only EB3C-R1CD Separate/Common Wiring Compatible Transistor (Sink/Source) EB3C-TD 8 EB3C-T08CKD* Sink 1 EB3C-T1CKD* Common Wiring Only 8 EB3C-T08CSD Transistor Source 1 EB3C-T1CSD 1 Connector Wiring Sink EB3C-T1CKD-C* Source EB3C-T1CSD-C Accessories Item Part Number Description DIN Rail BAP00 Steel (1m long, 7.5mm high) BNDN00 Aluminum (1m long,.5mm high) End Clip BNL Medium DIN rail end clip 800-22-IDEC (4332) USA & Canada 225

Explosion-Protection and Electrical Specifications Degree of Protection Installation Location Relay Barrier Non-intrinsically Safe Circuit Maximum Voltage (Um) Intrinsically Safe Circuits Non-intrinsically Safe Circuits See Certification Numbers table below IP20 (IEC0529) Safe indoor place (non-hazardous area) 1-channel Wiring Method Separate Wiring Rated Operating Voltage 12V DC ±% Rated Operating Current ma DC ±20% Maximum Output Voltage (Uo) 13.2V DC 250V AC 50/0Hz, 250V DC 125V AC 50/0Hz, 125V DC (UL rating) 1-channel Common Wiring Maximum Output Current (lo) 14.2 ma 227.2 ma Maximum Output Power (Po) 4.9 mw 750 mw Maximum External Inductance (Lo)* 175 (125) mh 0.8 (0.8) mh Maximum External Capacitance (Co)* 900 (740) nf Allowable Wiring Resistance (Rw) 300Ω 00/(n+1)Ω (n = number of common channels) Maximum Channels per Common Line 1 Contact Configuration 1NO Rated Insulation Voltage (Ui) 250V AC (UL rating: 125V AC), 125V DC Thermal Current (lth) 3A (common terminal: 8A) Contact Resistive AC: 750 VA, DC: 72W Allowable AC: 750 VA (cos ø = 0.3 to 0.4) Power Inductive DC: 48W (L/R = 7 ms) Resistive 250V AC 3A, 3A Rated 250V AC 3A (cos ø = 0.3 to 0.4) Inductive 2A (L/R = 7 ms) Minimum Applicable 0.1V DC, 0.1 ma (reference value) Contact Resistance 50 mω ON Time 12 ms maximum (rated voltage) OFF Time ms maximum (rated voltage) Mechanical Life 20,000,000 operations minimum (at 18,000 operations/hour, without load) Electrical Life 0,000 operations minimum (at 1,800 operations/hour, rated load) Short-circuit Protection None Rated Voltage Maximum Voltage 30V DC Maximum Current 0 ma (connector type: 15 ma) Leakage Current 0.1 ma maximum Voltage Drop 1V maximum Clamping Voltage 33V (1W) Inrush Current 0.5A maximum (1 sec) ON Time 0.1 ms maximum (resistive load) OFF Time 0.4 ms (typical) (resistive load) Short-circuit Protection None Relay Output Transistor Output Specifications General Specifications Values in ( ) are those approved by TIIS (Technology Institution of Industrial Safety, Japan). Note: Um = 125V AC for UL ratings AC DC Rated Voltage 0 to 240V AC (UL rating: 0 120V AC) Allowable Voltage Range 85 to 24V AC (UL rating: 85 125V AC) 21. to 2.4V DC Rated Frequency 50/0 Hz (allowable range: 47 to 3 Hz) Inrush Current A (0V AC) 20A (200V AC) A Between intrinsically safe circuit and non-intrinsically safe circuit: 1500V AC Dielectric Strength (1 minute, 1 ma) Between AC power and output terminal: 1500V AC Between DC power and transistor output terminal: 00V AC Operating Temperature 20 to +0 C (no freezing) Storage Temperature 20 to +0 C (no freezing) Operating Humidity 45 to 85% RH (no condensation) Atmosphere 800 to 10 hpa Pollution Degree 2 (IEC04) Insulation Resistance MΩ minimum (500V DC megger, between the same poles as the dielectric strength) Panel mounting: to 55 Hz, amplitude 0.75 mm Damage Limits Vibration DIN rail mounting: to 55 Hz, amplitude 0.35 mm Resistance Operation Extremes (relay output only) Panel mounting: to 55 Hz, amplitude 0.5 mm DIN rail mounting: to 55 Hz, amplitude 0.35 mm Shock Panel mounting: 500 m/s 2 (3 times each on X, Y, Z) Damage Limits Resistance DIN rail mounting: 300 m/s 2 (3 times each on X, Y, Z) Terminal Style M3 screw terminal Mounting 35-mm-wide DIN rail or panel mounting (M4 screw) Power Consumption (approx.) 9. VA (EB3C-RA at 200V AC) 4.8 W (EB3C-R1CD at ) Weight (approx.) 390g (EB3C-R1CD) Certification Numbers Certification Organization Certification Number Class I, II, III Div. 1 UL/FM Groups A, B, C, D, E, F and G 3015417 UL file: E234997 Class I, Zone 0 AEx [ia] IIC CSA Class I Div. 1 Groups A, B, C, D 1730 NEMKO [Exia] II C Nemko 02ATEX279 TIIS Japan Relay barrier: [Exia] II C TC15753 Class NK [Exia] II C 02T0 GOST-R [Exia] II C KOSHA [Exia] II C 11-AV4BO-0457 CQST [Exia] II C CNEx.2445 Class NK is Japan Shipping agency approval, Class KR is Korean shipping agency approval. 22 www.idec.com

EB3C Internal Circuit Block Diagrams AC Power, Relay Output Type P1 N1 P2 N2 P3 N3 Yellow Yellow Yellow L N A1 C1 A2 C2 A3 C3 External Wiring Examples Transistor Sink Output Type (Ex.: EB3C-T08CKD) Relay Output Type (Ex.: EB3C-R0A) DC Power, Transistor Output Type + P1 N1 P2 N2 P3 N3 Yellow Yellow Yellow A1 C1 A2 C2 A3 C3 P1 N1 P2 N2 P3 N3 P4 N4 P5 N5 P N Circuit Diagrams L N A1 C1 A2 C2 A3 C3 A4 C4 A5 C5 A C AC Power Connector Wiring, Sink Output Type Wiring Examples Power AC/DC P1 P1 N1 N2 Yellow Yellow + A1 A1 C1 C2 Transistor Source Output Type (Ex.: EB3C-T08CSD) Hazardous Area Non-hazardous Area P1 P2 P3 P4 P5 P P7 P8 N1 N2 + A1 A2 A3 A4 A5 A A7 A8 C1 C2 Transistor Output Type (Ex.: EB3C-T0A) Power P1 N1 P2 N2 P3 N3 P4 N4 P5 N5 P N L N A1 C1 A2 C2 A3 C3 A4 C4 A5 C5 A C AC Power Power 800-22-IDEC (4332) USA & Canada 227

EB3C *01 EB3C *02 EB3C *03 Dimensions (mm) EB3C *05 EB3C *0 EB3C *08C EB3C *08 EB3C * EB3C *1C 42 1.5 171.5 77.5 ø4.4 ø hole 1 77.5 75 (4) Connector EB3C T1C -C 77.5 (4) 75 4 Mounting Hole Layout (Screw Mounting) 2-ø4.5 mounting holes 171.5 97 2-ø4.5 mounting holes 2-ø4.5 mounting holes 28 51 97 97 ø 83.5 4- ø4.5 holes 4-M4 or 4-ø4.5 holes 97 Mounting Hole Layout 4-M4 tapped or 4-ø4.5 mounting holes Applicable Crimping Terminal ø3.2 min. max. 3 max. Stripping the Wire End Solid Wire to 8 mm Stranded Wire (Ferrule) to 8 mm 5.4 min. 228 www.idec.com