SIMATIC Ident RFID systems SIMATIC RF260X antenna multiplexer

Similar documents
SIMATIC Ident RFID systems ANT 3 Compact Operating Instructions

5.5 SLG 75. Read/Write Devices Read/Write Antennas

SIMATIC Ident. RFID systems SIMATIC RF615A. Characteristics 1. Ordering data. Installing and mounting. Connecting the antenna 4

SIMATIC Ident RFID systems SIMATIC RF310R special version Scanmode Compact Operating Instructions

SIMATIC Ident. RFID systems SIMATIC RF200 IO-Link V1.1. Introduction 1. Description. System overview. Planning an RF200 IO-Link system 4

MOBY-D Family Matrix

SICLOCK DCFRS Industrial Version with TTY Interface 2XV9450-1AR21

JUMO Wtrans probe RTD temperature probe with wireless transmission of the measured values

RFID SYSTEMS SIMATIC RF600. System Manual 02/2013. SIMATIC Ident. Answers for industry.

6-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT set by

Digital electronic module 4DO DC24V/2A HF (6ES7132-4BD30-0AB0) SIMATIC

XXXX e. X d.. X X X a

Subject to changes 11/2003 Page 1/7

JUMO Wtrans Receiver Universal Receiver for JUMO Wireless Measuring Probes

Electrical devices may only be mounted and connected by electrically skilled persons.

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

Installation and Quick Reference Guide. Disclaimer and warranty 2. Contents of this box 2. Brief background to AIS 3.

4-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT set by

HG G B. Gyroscope. Gyro for AGV. Device Description HG G B. Innovation through Guidance. Autonomous Vehicles

Standard Sendix 5000 / 5020 (shaft / hollow shaft) Push-Pull / RS422 / Open collector. Robust performance. Many variants

12-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT set by

12-Port Antenna Frequency Range Dual Polarization HPBW Adjust. Electr. DT set by

E205 Long Range Wireless Modem V1.0 Data Sheet

SIMATIC RTLS. Localization systems SIMATIC RTLS PCB OEM AX (6GT2700-8DF00-0AX0) Device manual 10/2018 C79000-G8976-C518-01

Phone: Fax: Web: -

XXXX e. X d.. X X X a

IBV 100/EXE 100 Interpolation and Digitizing Electronics

Rotary Measuring Technology

EC centrifugal fan. backward curved, single inlet

ENCODER. Analog Multiturn Encoder. Serie 8.M5861. Key-Features:

Absolute Encoders Multiturn

SIMATIC. ET 200S distributed I/O 2AI U HF analog electronic module (6ES7134-4LB02-0AB0) Preface. Properties 1. Parameters 2.

SIMATIC ET 200SP. Digital input module DI 8xNAMUR (6ES7131-6TF00-0CA0) Manual. Answers for industry.

Incremental encoders Blind hollow shaft or cone shaft pulses per revolution

FA Wireless SS Terminals

4-Port Antenna ircu / /65 16/18.5dBi 0 10 /0 10 T V01

Absolute Encoders Multiturn

Operating instructions. RFID UHF reader DTE800 DTE810 DTE900 DTE910 DTE / / 2017

JUMO Wtrans Receiver with Wireless Data Transmission

RoHS. High shaft load capacity. Shock / vibration resistant

Absolute Encoders - Singleturn

Absolute Encoders Singleturn

EC centrifugal fan. backward curved, single inlet

Technical data. Your advantages

02/11/2015

Absolute Encoders - Singleturn

INSTALLATION MANUAL FOR RADIO CONTROL SESAM 6099 TRANSMITTER

Rotary Measurement Technology Incremental Encoders

Torque Sensor Series 3000 and Series 4000

P/N: AX06080X. TECHNICAL DATASHEET #TDAX06080X Triaxial Inclinometer SAE J1939 or CANopen 2 M12 Connector(s), IP67 with Electronic Assistant

em4 em4 alert em4 alert 2G

Installation Instructions RF-identification system Read/write head DTM434 DTM435 DTM436 DTM437

PowerPlex Compact Module PP-C-COM24

TECHNICAL DATASHEET Absolute Encoder AC 58 - BiSS / SSI

Symbols on the equipment. WARNING! Dangerous voltage!

Technical Documentation

ICAM. Electronics & Software. Industrial Charge Amplifier for Applications in Manufacturing. Type 5073A...

EC centrifugal fan. backward curved, single inlet

Technical data. General specifications V DC No-load supply current I 0. typ. 50 ma Power consumption P 0

MPR kHz Reader

ENCODER. SSI Multiturn. Series , Key-Features: Content:

Technical data. Your advantages

Product Information ECI 1319S EQI 1331S. Absolute Rotary Encoders without Integral Bearing and with DRIVE-CLiQ Interface.

DB 112 B. Double Sheet Testing Unit TECHNICAL DESCRIPTION. en / We reserve the right to. make technical changes

ECOS SRIF Operating Instructions

TZIF 4. Current-to-Pulse Converter 10/ EN

V720 series RFID system

02/11/2015

My-IDENT... Industrial Identification Program. High performance RFID. MEYLE: Know-How, Know-Where, Know-When RADIO FREQUENCY IDENTIFICATION

User Manual CTP4/8/16

Heavy Duty Push-pull / RS422 / speed switch. RoHS 2/22. Magnetic field proof. XXXX e

Torque Sensor DML 500 S080S10X

GSM-R Terminal filter Technical Specification

NOVOHALL Rotary Sensor touchless transmissive. Series RFX-6900

Ethernet to 900 MHz RF Modem

Measuring systems. 7/2 Overview. 7/3 Built-on optoelectronic rotary encoders 7/3 Introduction

Special Events Multibeam Antenna

TECHNICAL DATASHEET Incremental Encoder RI 30

AC 3. Active Antenna Combiner. Instruction manual

Type 3RW RW40 7. Control electronics Rated values. Terminal. external DC supply (to DIN 19240) through terminals and IN Relay outputs

Ultra-wideband Bi-SectorTM Array

Directional valves Electrically operated Series 563, 565, 567. Brochure

Product Overview. Rotary Encoders with Optimized Scanning

SIMATIC. ET 200S distributed I/O 2AI I 4WIRE HS analog electronic module (6ES7134-4GB62-0AB0) Preface. Properties 1. Parameters 2.

Installation Instructions RF-identification system Read/write head ANT513

Multi-band Bi-Sector TM Array

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Receiver Type /Version Factory No. Frequency. Transmitter Type /Version Factory No. Frequency

DATA SHEET. OD Precision. Displacement sensors for precise and comprehensive measurement tasks

RFID UHF Products 2011

This data sheet is only valid in association with the IL SYS INST UM E user manual.

SIMATIC Vision Sensor SIMATIC VS130-2 and VS 130-2vcr

Radio Touch Order no.: 2880 xx. Operation and installation instructions. 1 Safety instructions. 2 Structure of the device (Figure 1) Radio Touch

ENCODER. Analog Multiturn Encoder. Serie 8.M3661/M3681. Key-Features:

WE-525T Antenna Analyzer Manual and Specification

Ha-VIS RFID Components

MG100 Single Axis MEMS Gyro

em4 local - Robust Specific characteristics Part number

Transcription:

SIMATIC Ident RFID systems Compact Operating Instructions Characteristics The can be used to operate up to six antennas on one reader. SIMATIC RF260X Characteristics antenna multiplexer Scope of application Designed for distributed mounting of antennas in warehouses, logistics and distribution Rugged housing and high degree of protection guarantee problemfree use under the most difficult industrial conditions. Read/write devices that can SLG D10 1) be connected Number of antennas that can Maximum 6 be connected Connectable antennas Degree of protection ANT D5 ANT D6 ANT D8 ANT D10 IP65 1) The RF260X antenna multiplexer is only parameterizable and operable with SLG D10 of AS: G (FW V5.04) and higher. Safety instructions for the device/system NOTICE This device/system may only be used for the application instances that have been described in the catalog and the technical documentation "MOBY D System Manual (http://support.automation.siemens.com/ww/view/en/13628689/0/en)" and only in combination with third-party devices and components recommended and/or approved by Siemens. Ordering data Table 1 SIMATIC RF260X ordering data Order Number SIMATIC RF260X Antenna multiplexer incl. connecting cable 0.4 m 6GT2894-0EA00 Siemens P2011 D0243-U001-A1-7618, 02/2011 1

Table 2 SIMATIC RF260X accessories ordering data Accessories SLG D10 ANT D5 incl. antenna cable (3.3 m) ANT D6 incl. antenna cable (3.3 m) ANT D8 incl. antenna cable (3.3 m) ANT D10 incl. antenna cable (3.3 m) Wide range power supply - EU version Wide range power supply - UK version Wide range power supply - US version Power supply cable, 5 m RS 232 connecting cable, 5 m RS 232 connecting cable, 20 m Antenna cable, length 10.5 m Antenna extension, length 7.2 m Order Number 6GT2698-1AA00 6GT2698-5AA00 6GT2698-5AB00 6GT2604-0AC00-0AX0 6GT2698-5AF00 6GT2898-0AA00 6GT2898-0AA10 6GT2898-0AA20 6GT2491-1HH50 6GT2691-0BH50 6GT2691-0BN20 6GT2691-0CN10 6GT2691-0DH72 Description 1 24 V DC power supply 2 Antenna connections OUT 1 to OUT 6 with LEDs Color Status LED Yellow Lit when the corresponding antenna output is active. 3 SLG antenna connection "IN" 4 LEDs LED Color Status LED COMM / ERR Red Flashes when the RF260X receives a signal from the SLG. (Only with commands, directly on the RF260X) Lit when the multiplexer has detected an error on the output (e.g. non-terminated antenna cable, defective antenna cable) HF - ON Green Lit when an HF signal is applied to the "IN" socket 3 RUN Green Flashes when the RF260X is in the normal operating state. Principle of operation You can operate up to six antennas on one reader via the multiplexer. The data is processed sequentially. Antenna switchover is performed in time-multiplex mode, so by connecting several antennas together, the processing time / activation time per antenna is lengthened accordingly. 2 D0243-U001-A1-7618, 02/2011

Connectors Power supply 1 Pin Pin, casing side Assignment 4-pin M12 RF260X 1 Ground (0 V) 2 + 24 V 3 + 24 V 4 Ground (0 V) SLG connection 3 Figure 1 SLG connection If a longer antenna cable is required between the SLG D10 and SIMATIC RF260X multiplexer, a 7.2 m long cable (e.g. 6GT2691-0DH72) must be used to extend it, see Ordering data (Page 1). The excess length must then be rolled up bifilar and fastened to minimize interference from external sources. Antenna outputs 2 (OUT 1 to OUT 3 / OUT 4 to OUT 6) D0243-U001-A1-7618, 02/2011 3

Configuration of SIMATIC RF260X Figure 2 Configuration example with ANT D5 4 D0243-U001-A1-7618, 02/2011

Parameterization Parameterization can be performed using the tool "MOBYDSet" (V7.5.5). This tool is primarily used for parameterization and commissioning, and is not designed for productive operation. The relevant parameters of the RF260X can be set in the "Configuration" menu under "SystemParameters > CFG15: Antenna Multiplexing" 1. Figure 3 Menu "Configuration" MOBYDSet" For operation with RF260X, the "Multiplexing" function 2 must be activated." The two antenna switchover options listed below are available under "Switching Condition" 3: Setting "b1, after Mux Valid Time": A fixed read time is specified in the field "MUX-VALID-TIME" 4. Setting "b0, after no response": In this case, when an MDS is detected the read is executed within the specified "MUX-VALID-TIME". If an MDS is not detected, switchover to the next channel is performed immediately. The number of reserved channels must be specified under "Number of Output Channels" 5. Note When the parameterization of the SLG or RF260X is changed in scanner mode, it is important to note that message frame collisions can occur if the message frame is transmitted when an MDS is present. The transponder response time (setting: CFG2: COM interface) during operation of the RF260X must be larger than the total switchover time for all the connected antennas (CFG15: MUX-VALD-TIME x Number of Output Channels Transponder Response Time) D0243-U001-A1-7618, 02/2011 5

RF260X commands The tools "MOBYDSet" (V7.5.5) can also be used to send specific commands to the RF260X. In the menu "RF260X Commands" under "Commands", the following commands can be sent: Detect (detection of the RF260X by the SLG) Channel Select (set to a static channel) CPU-Reset (restart the RF260X software) Software Version (read out software and hardware versions) Figure 4 Sending commands from the tool "MOBYDSet" 6 D0243-U001-A1-7618, 02/2011

Technical specifications Table 3 Technical specifications of SIMATIC RF260X Max. write/read distance ANT to MDS (Sg) See manual for the relevant antenna Number of input channels 1 Number of output channels 6 Impedance 50 ohm Power supply in V: 24 (± 10 %) Load current in ma: max. 200 Dimensions in mm (L x W x H) 240 x 150 x 70 Length of the SLG connection cable (included in scope of 0.4 m delivery) Color Anthracite Material Aluminum die-casting Plug-in connections Power supply: Four-pole M12 / 4 pole round connector SLG antenna connection: Single-pole TNC socket Antenna connections: 6 x TNC socket Max. performance (SLG input, or per antenna) 8 W Shock resistant according to EN 60721-3-7 Class 7M2 1 g Total shock response spectrum Type II Vibration compliant with EN 60721-3-7 Class 7M2 1.5 g (5 to 500 Hz) Fixing 4 x M5 screws Tightening torque 5 Nm (at room temperature) Ambient temperature During operation During transportation and storage -20 C to +55 C -25 C to +70 C MTBF 2.5 x 10 6 hours Degree of protection to EN 60529 IP65 Weight, approx. 1.8 kg Approvals CE FCC IC D0243-U001-A1-7618, 02/2011 7

Dimensional drawing Dimensions in mm Figure 5 RF260X dimension drawing Service & Support Technical support Phone: + 49 (0) 911 895 7222 Fax: + 49 (0) 911 895 7223 E-mail (mailto:support.automation@siemens.com) Internet: Online support request form: (www.siemens.com/automation/support-request) Service & support at IA/DT Support homepage (www.siemens.com/automation/service&support) RFID homepage For general information about our identification systems, visit RFID homepage (http://www.siemens.com/ident). Siemens AG Industry Sector Postfach 48 48 90026 NÜRNBERG 8 D0243-U001-A1-7618, 02/2011 D0243-U001-A1-7618, 02/2011