Research Article Fabrication and Performance Test of Fresnel Zone Plate with 35 nm Outermost Zone Width in Hard X-Ray Region

Similar documents
Making hard x-ray micro-focus beam and imaging microscope with Fresnel zone plate optics. -SPring-8 summer school text- September 2008

Making hard x-ray micro-focus beam and imaging microscopy with Fresnel zone plate optics. -SPring-8 summer school text- Sept Revised June 2009,

Sub-50 nm period patterns with EUV interference lithography

EUV and Soft X-Ray Optics

Zone-plate-array lithography using synchrotron radiation

Supplementary Figure 1. Effect of the spacer thickness on the resonance properties of the gold and silver metasurface layers.

Diffraction-limited Microbeam with Fresnel Zone Plate Optics in Hard X-Ray Regions

Confocal Imaging Through Scattering Media with a Volume Holographic Filter

EE-527: MicroFabrication

Chapter Ray and Wave Optics

Microspot x-ray focusing using a short focal-length compound refractive lenses

Sensitive measurement of partial coherence using a pinhole array

Diffractive optical elements based on Fourier optical techniques: a new class of optics for extreme ultraviolet and soft x-ray wavelengths

pcvd diamond beam position monitors for PETRA III

Experience of synchrotron sources and optics modelling at Diamond Light Source

Diffraction. Interference with more than 2 beams. Diffraction gratings. Diffraction by an aperture. Diffraction of a laser beam

Research Article Spherical Aberration Correction Using Refractive-Diffractive Lenses with an Analytic-Numerical Method

X-ray generation by femtosecond laser pulses and its application to soft X-ray imaging microscope

Focusing X-ray beams below 50 nm using bent multilayers. O. Hignette Optics group. European Synchrotron Radiation Facility (FRANCE) Outline

Applied Optics. , Physics Department (Room #36-401) , ,

INTRODUCTION THIN LENSES. Introduction. given by the paraxial refraction equation derived last lecture: Thin lenses (19.1) = 1. Double-lens systems

CHAPTER TWO METALLOGRAPHY & MICROSCOPY

R.B.V.R.R. WOMEN S COLLEGE (AUTONOMOUS) Narayanaguda, Hyderabad.

k λ NA Resolution of optical systems depends on the wavelength visible light λ = 500 nm Extreme ultra-violet and soft x-ray light λ = 1-50 nm

Low Contrast Dielectric Metasurface Optics. Arka Majumdar 1,2,+ 8 pages, 4 figures S1-S4

MICRO AND NANOPROCESSING TECHNOLOGIES

Microlens formation using heavily dyed photoresist in a single step

Fabrication, testing, and performance of a variable-focus x-ray compound lens

Supplementary Figure 1. GO thin film thickness characterization. The thickness of the prepared GO thin

Introduction to Electron Microscopy

Study on Imaging Quality of Water Ball Lens

Optical Coherence: Recreation of the Experiment of Thompson and Wolf

CHAPTER 2 Principle and Design

Supplementary Figure 1 Reflective and refractive behaviors of light with normal

Be aware that there is no universal notation for the various quantities.

Development of a new multi-wavelength confocal surface profilometer for in-situ automatic optical inspection (AOI)

EUV Interference Lithography in NewSUBARU

Fabrication of Probes for High Resolution Optical Microscopy

Major Fabrication Steps in MOS Process Flow

Will contain image distance after raytrace Will contain image height after raytrace

MASSACHUSETTS INSTITUTE OF TECHNOLOGY. 2.71/2.710 Optics Spring 14 Practice Problems Posted May 11, 2014

Niklas Norrby 12/17/2010

Nano Beam Position Monitor

Supporting Information

X-Ray Microfocusing Optics. Barry Lai X-Ray Science Division Advanced Photon Source

Supplementary Figure S1. Schematic representation of different functionalities that could be

attocfm I for Surface Quality Inspection NANOSCOPY APPLICATION NOTE M01 RELATED PRODUCTS G

Optimization of Beamline BL41XU for Measurement of Micro-Protein Crystal

Reflection! Reflection and Virtual Image!

Confocal Microscopy and Related Techniques

Anti-reflection Coatings

arxiv: v2 [astro-ph.im] 22 Sep 2011

Fabrication of micro structures on curve surface by X-ray lithography

Infrared Perfect Absorbers Fabricated by Colloidal Mask Etching of Al-Al 2 O 3 -Al Trilayers

Applications of Optics

Bringing Answers to the Surface

Modulation Transfer Function

EUV Plasma Source with IR Power Recycling

Test procedures Page: 1 of 5

Scanning X-ray microscopy with a single photon counting 2D detector

Transmission electron Microscopy

BEAM HALO OBSERVATION BY CORONAGRAPH

Chapter 18 Optical Elements

Optics and Lasers. Matt Young. Including Fibers and Optical Waveguides

Testing Aspheric Lenses: New Approaches

The Scanning Transmission X-Ray Microscope at BESSY II

High-Speed Scalable Silicon-MoS 2 P-N Heterojunction Photodetectors

Experiment 1: Fraunhofer Diffraction of Light by a Single Slit

Supplementary Information

ABC Math Student Copy. N. May ABC Math Student Copy. Physics Week 13(Sem. 2) Name. Light Chapter Summary Cont d 2

Examination, TEN1, in courses SK2500/SK2501, Physics of Biomedical Microscopy,

TOWARDS SUB-100 NM X-RAY MICROSCOPY FOR TOMOGRAPHIC APPLICATIONS

Exam 4. Name: Class: Date: Multiple Choice Identify the choice that best completes the statement or answers the question.

RANDY W. ALKIRE, GEROLD ROSENBAUM AND GWYNDAF EVANS

EE119 Introduction to Optical Engineering Spring 2003 Final Exam. Name:

High Precision Positioning Mechanisms for a Hard X-ray Nanoprobe Instrument. Abstract

Georgia Tech IEN EBL Facility NNIN Highlights 2014 External User Projects

A simple null-field ellipsometric imaging system (NEIS) for in situ monitoring of EUV-induced deposition on EUV optics

Lithography. 3 rd. lecture: introduction. Prof. Yosi Shacham-Diamand. Fall 2004

A thin foil optical strain gage based on silicon-on-insulator microresonators

Point Spread Function. Confocal Laser Scanning Microscopy. Confocal Aperture. Optical aberrations. Alternative Scanning Microscopy

Chapter 36: diffraction

Talbot- Lau interferometry with a non- binary phase grating for non-destructive testing

NanoSpective, Inc Progress Drive Suite 137 Orlando, Florida

Optical design of a high resolution vision lens

plasmonic nanoblock pair

IMAGE SENSOR SOLUTIONS. KAC-96-1/5" Lens Kit. KODAK KAC-96-1/5" Lens Kit. for use with the KODAK CMOS Image Sensors. November 2004 Revision 2

Wir schaffen Wissen heute für morgen

Reflectors vs. Refractors

SUPPLEMENTARY INFORMATION

Micro- and Nano-Technology... for Optics

The optical analysis of the proposed Schmidt camera design.

TSBB09 Image Sensors 2018-HT2. Image Formation Part 1

High-yield Fabrication Methods for MEMS Tilt Mirror Array for Optical Switches

membrane sample EUV characterization

Water-Window Microscope Based on Nitrogen Plasma Capillary Discharge Source

Scanning Electron Microscopy. EMSE-515 F. Ernst

Figure 7 Dynamic range expansion of Shack- Hartmann sensor using a spatial-light modulator

EE119 Introduction to Optical Engineering Spring 2002 Final Exam. Name:

Coherent Laser Measurement and Control Beam Diagnostics

Transcription:

Hindawi Publishing Corporation X-Ray Optics and Instrumentation Volume 2010, Article ID 824387, 6 pages doi:10.1155/2010/824387 Research Article Fabrication and Performance Test of Fresnel Zone Plate with 35 nm Outermost Zone Width in Hard X-Ray Region Yoshio Suzuki, 1 Akihisa Takeuchi, 1 Hisataka Takenaka, 2 and Ikuo Okada 2 1 Japan Synchrotron Radiation Research Insitute (JASRI)/SPring-8, Sayo Hyogo 679-5198, Japan 2 NTT-AT Nanofabrication Corporation, Atsugi, Kanagawa 243-0018, Japan Correspondence should be addressed to Yoshio Suzuki, yoshio@spring8.or.jp Received 29 October 2009; Accepted 17 June 2010 Academic Editor: Ali Khounsary Copyright 2010 Yoshio Suzuki et al. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. A Fresnel zone plate (FZP) with 35 nm outermost zone width has been fabricated and tested in the hard X-ray region. The FZP was made by electron beam lithography and reactive ion etching technique. The performance test of the FZP was carried out by measuring the focused beam profile for coherent hard X-ray beam at the beamline 20XU of SPring-8. The full width at half maximum of the focused beam profile measured by knife-edge scan method is 34.9 ± 2.7 nm, that agrees well with the theoretical value of diffraction-limited resolution. Applications to scanning microscopy were also carried out. 1. Introduction Many types of optical elements for X-ray microfocusing and microimaging in the hard X-ray regions have been developed. Fresnel zone plates [1], total reflection mirrors [2], multilayer mirrors [3], refractive lenses [4], and multilayer Laue lenses [5] were fabricated and applied to microfocusing of synchrotron radiation X-rays. At present, the Fresnel zone plate (FZP) manufactured by electron beam lithography is one of the best optical elements for X-ray microscopy because of its high spatial resolution (better than 50 nm), negligibly small coma and small field distortion. The chromatic aberrations of FZP are usually ignorable in the hard X-ray region, because the crystal monochromators used in the synchrotron radiation beamlines produce sufficient monochromaticity for hard X-rays (λ/δλ 10000). Thus, the spatial resolution of FZP optics is simply determined by the numerical aperture and by the accuracy of zone structure. Spatial resolution of about 30 nm is already achieved with conventional FZPs. However, these results are carried out using third-order diffraction of FZP with an outermost zone width of 50 nm [1, 6]. Although a gold zone plate with 24 nm outermost zone width is also fabricated and tested in hard X-ray region [7], its spatial resolution has not been reported. Some X-ray focusing optics of spatial resolution better than 30 nm is already reported [2, 5]. However, they are still one-dimensional focusing, and these optical elements, the multilayer Laue lenses, or the aspherical Kirkpatrick-Baez mirrors are not image-forming optics. The Fresnel zone plate in the hard X-ray region is an almost ideal image-forming optical devise up to a spatial resolution of around 10 nm [8, 9]. Therefore, the conventional FZP is still indispensable for hard X-ray microscopy. In this report, recent development of FZP with an outermost zone width of 35 nm is presented, and characterization of the FZP in the hard X-ray region is described. 2. Fresnel Zone Plate Fabrication The FZP was fabricated at NTT-AT Nanofabrication by electron beam lithography and reactive ion etching technique. The fabrication process of FZP is shown in Figure 1. The substrate is composed of 2 μm silicon nitride (SiN) membrane deposited on a Si wafer by low pressure chemical vapor deposition (CVD) method. Tantalum film with a thickness of 0.175 μm was deposited by rf-sputtering method, and SiO 2 film was deposited by electron cyclotron resonance (ECR) plasma CVD method on the Ta layer as an etching mask of Ta. The FZP patterns were written by point electron-beam exposure method. The SiO 2 film was etched with resist mask by the reactive ion etching, and the Ta film was dry-etched with SiO 2 mask by an ECR ion-stream etching. Finally, the

2 X-Ray Optics and Instrumentation Film deposition EB writing Absorber (Ta) etching SiO 2 Ta SiN Si wafer Resist Here, N is total number of zone. In order to satisfy the Rayleigh s λ/4 rule, we chose N = 1265, that is, r N = 88.56 μm (diameter of 177.12μm). Then, the outermost zone width becomes 35.00 nm. The λ/4 rule is satisfied in the wavelength region shorter than 2.8 nm. Thus, the spherical aberration can be ignored in the hard X-ray region. The theoretical spatial resolution (Rayleigh resolution limit) for the first-order diffraction of FZP is known to be 1.22d N,whered N is the width of outermost zone [12]. Therefore, if the zone structure is ideal, spatial resolution of the FZP could be 43 nm. It should be noted that the knifeedge scan method, which is generally used for measuring the focused beam shape, gives a line spread function of beam profile. The line-spread-function, LSF(x), of a diffractionlimited focal spot for circular aperture lens is given by onedimensional integral of point spread function as ( ( )) 2 2J1 x2 + y 2 LSF(x) = x 2 + y 2 dy, (4) Back etching Ta SiN Si wafer Figure 1: Processing step of Fresnel zone plate manufacturing. Si wafer was back etched with KOH solution for windowing. The details of fabrication method of tantalum zone plates at the NTT-AT Nanofabrication are already reported elsewhere [10, 11]. Schematic drawing of the FZP structure and its SEM image is shown in Figure 2. The design width of outermost zone that determines the diffraction-limited resolution is 35 nm. The SEM image shows a cross section of outermost zone structure that was prepared from the duplicated FZP. Fine zone structures of 35 nm width are precisely formed as shown in the figure. The zone pattern is designed by the simple formula of FZP as r 2 n = nλ f, (1) where n is integer of zone number, λ is an X-ray wave length, and f is focal length. We used a parameter set of λ = 0.155 nm (hν = 8keV) and f = 40 mm. Comparing with the spherical-aberration-corrected exact equation of zone pattern for focusing a plane wave, rn 2 = nλ f + n2 λ 2 4, (2) it is required that f is much greater than nλ/4 for the ignorable spherical aberrations [12]. According to the Rayleigh s quarter wavelength rule [13], the spherical aberration can be ignored, when the following condition is satisfied [8]: N 2 2 < f λ. (3) where J 1 (x) is a Bessel function of the first kind. The Rayleigh s criterion for spatial resolution is defined by the first minimum of the Bessel function as J 1 (x 1 ) = 0, and the solution of x 1 = 1.220π is usually used as a definition of diffraction-limited resolution [13], while the full width at half maximum (FWHM) of point-spreadfunction, {2J 1 (x)/x} 2, is 1.0290π. It is shown by the numerical calculation of the above formula that the FWHM of line-spread-function is given by x = 1.0016π. Therefore, the FWHM of line-spread-function is nearly equal to the outermost zone width of ideal FZP, and the theoretical FWHM of knife-edge scan profile for the diffraction-limited micro focus beam is 1.0016d N. The calculated diffraction efficiency for the 0.175 μmthick tantalum FZP is only 0.8% for 8 kev X-rays. This low efficiency may sometimes be a problem for nanobeam applications or for imaging microscopy because of low signal intensity. However, the low diffraction efficiency can be compensated by high brilliance X-ray sources. Some scanning microscopy experiments can be carried out with this zone plate, and the application to the imaging microscopy would also be capable at the expense of relatively long exposure time and high radiation dose to specimen. This low diffraction efficiency is not a problem for characterization of FZP. The thickness of FZP (0.175 μm) is, however, not optimized for 8 kev X-rays. The optimum thickness of Ta zone plate for 8 kev is 1.9 μm. Therefore, higher aspect ratio of zone structure is required for improvement of diffraction efficiency. The aspect ratio of tantalum one-to-one zone structure is presently limited by technological reason, mainly for reactive dry-etching process. The present limit of aspect ratio is about 10. The aspect ratio doubling by stacking two zone plates [7] would be a promising method for higher diffraction efficiency. Zone material of high electron density is adequate for X-ray zone plates, because the optimized thickness is in proportion to the reciprocal of electron density. Gold is generally chosen as the zone material for its high density and fabrication technology, for example, electroplating of gold. The density of tantalum is less than

X-Ray Optics and Instrumentation 3 Ta zone structure Support membrane Ru/Si 3 N 4 20 nm/2 μm Si wafer, 1 mm-thick 100 nm Figure 2: Schematic drawing and cross-sectional SEM image of Fresnel zone plate fabricated by electron beam lithography method. Width of outermost zone is 35 nm. In-vacuum undulator Monochromator Cross-slit for pseudo-point source (50 μm) Si 111 E/ΔE 7000 FZP OSA Beam stop 245mfromsourcepoint 195 m f Knife-edge scan Figure 3: Experimental setup for X-ray nanofocusing at the beamline 20XU of SPring-8. FZP: Fresnel zone plate. OSA: order selecting aperture, a pinhole with 20 μm-diameter made of 0.3 mm-thick platinum plate. Beam Stop: direct beam stop for dark-field edge-scan, tantalum 3 mm-thick plate. that of gold by about 14%. Therefore, the zone plate made of Ta usually gives lower efficiency than that made of Au in the case of same zone thickness. However, we consider that the difference of diffraction efficiency is not significant, and the tantalum is also one of the best materials for hard X-ray zone plates. In some cases, for example, near the absorption edge of gold, tantalum zone plate with the same thickness can give slightly higher efficiency than gold zone plate. 3. Performance Test of FZP Performance test of the FZP as a nanofocusing optics has been carried out at the beamline 20XU [14] of SPring- 8. A schematic view of the experimental setup is shown in Figure 3. An X-ray energy of 8 kev was chosen in the experiment. The energy resolution of monochromator is about 1.1 ev for 8 kev X-rays. To avoid the chromatic aberration of FZP optics, the relative spectral bandwidth of incident X-ray beam, Δλ/λ, must be less than or equal to the inverse of total number of zone [12], as Normalized intensity (a.u.) FWHM = 34.4nm 0 150 100 50 0 50 100 150 Distance (nm) Δλ λ 1 N. (5) Comparing with the zone number of the FZP, N = 1265, the monochromaticity of ΔE/E 1/7000 is sufficient for testing the performance of FZP. Figure 4: Focused beam profile measured by dark-field edge scan. Edge scan was carried out with 3.125 nm step and 1 s integration time per point. X-ray energy is 8 kev. An edge of tantalum thin film (0.5 μm-thick) is used as a knife-edge. Solid circles are measured data, and the red line represents theoretical profile for ideal circular aperture lens. Signal current of ionization chamber is about 2 pa at the peak.

4 X-Ray Optics and Instrumentation 1 Response 0.5 Rayleigh limit 0 0 10 20 30 40 50 Spatial frequency (μm 1 ) Figure 5: Modulation transfer function. Solid circles are MFT calculated from the measured beam profile shown in Figure 4. Red line is theoretical MTF obtained by numerical calculation of line-spread function. OSA Diffracted beam Sample Direct beam FZP Rotatable beam-stop Detector (ionization chamber) Figure 6: Schematic view of scanning microscopy setup for bright and dark field method. A lead thin plate (0.5 mm) beam stop is mounted on a rotating stage, and bright-field and dark-field imaging can be exchanged by rotating the beam stop. The monochromatic beam is transported through the 200-m-long vacuum duct and is extracted in to the air at an end experimental station located at approximately 245 m from the light source. A precise cross slit located 49 m from the source is used as a pseudopoint source for determining the spatial coherence at the end station. The cross slit with an opening of 50 μm 50 μm was used in the present experiment. Therefore, the geometrical spot size for an FZP with a focal length of 40 mm becomes 10 nm that is much less than the diffraction-limited resolution of the FZP. There are no optical elements between the cross-slit virtual source and the experimental station, except for a beamline X-ray window made of 125 μm-thick polyimide. The focus spot profile is evaluated by knife-edge scan method. However, it is difficult to fabricate precise knifeedge for characterization of nano-focusing beam, because of high transmissivity of hard X-ray beam. So, the conventional knife-edge test cannot be used for the present experiment. We employed dark-field method for the knife-edge test [1]. A pattern edge of tantalum resolution test chart is used as a knife-edge. The thickness of tantalum test pattern is 0.5 μm, which corresponds to an optical path difference of about λ/8 at an X-ray wavelength of 0.155 nm. The intensity of the diffracted wave takes its maximum at an optical thickness of λ/2 for phase edge. Therefore, from point of view of signal intensity, the optimum thickness of knife-edge for dark-field method is λ/2. However, the thickness of λ/8 is still sufficient for the beam profile measurement. The thicker knife-edge may give higher dark-field signal, but the thickness must be much less than the depth of focus that is 7.9 μm in the present experimental condition. The test pattern edge was set parallel to the optical axis in order to avoid broadening of edge-scan profiles. The misalignment of substrate of test pattern was within an angle of about 0.3 degree. The knife-edge scanning was carried out using a conventional mechanical stage driven by an open-loop-controlled

X-Ray Optics and Instrumentation 5 10 μm 1 μm 1 0.9 Line (μm) 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 (a) (b) 0.9 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 Space (μm) (c) Figure 7: Scanning microscopy images of line and space test patterns. X-ray energy is 8 kev. (a) Bright field image, 50 nm pixel size and 0.2 s dwell time. (b) Dark field image, 12.5 nm pixel size and 0.2 s dwell time. (c) Schematic drawing of line and space patterns. Black area corresponds to tantalum-deposited regions. step motor. The accuracy of the translation stage is measured to be better than 10 nm [15]. The X-ray beam intensity was measured with ionization chamber detectors with 14 cm electrode length. One is an air-flowed ionization chamber placed in front of the FZP, and the other is an argon-flowed ionization chamber behind the knife-edge. A beam stop is placed in front of the argon-flowed ionization chamber for the purpose of dark-field edge scan. A typical example of measured beam profiles is shown in Figure 4. The FWHM of the focused beam profile shown in Figure 4 is 34.4 nm. The accuracy of beam size measurement was estimated from repeatability of measured beam size. The average of thirteen measurements around the focus is 34.9 nm, and the error of beam size measurement is 2.7 nm in standard deviation. Therefore, it is concluded that the focused beam size is 34.9 nm ± 2.7 nm in FWHM. As shown in the figure, the measured beam profile agrees well with the theoretical one. It is concluded that nanometer-resolution imaging is capable in the hard X-ray region by using the FZP as a beam-focusing device or as an objective lens for imaging microscopy. The measured diffraction efficiency of the FZP is 0.7% for 8 kev X-rays. This value agrees well with the theoretical efficiency (0.8%) of 0.175 μm-thick Ta zone plate. Modulation transfer function (MTF) obtained from the measured beam profile in Figure 4 is shown in Figure 5. The Rayleigh s resolution limit (1.22d N )for35nm outermost zone width that corresponds to a spatial frequency of 23.4 μm 1 is indicated by an arrow in the figure. The measuredmtfat23.4cycle/μm is about 10%. 4. Scanning Microscopy Experiments Experimental setup for scanning microscopy experiment is shown in Figure 6. Bright field imaging and dark-field imaging [16] can be exchanged by rotating the beam stop in front of the detector. The beam stop is made of a lead plate with a thickness of 0.5 mm. Scanning microscopy images of a test object are shown in Figures 7(a) and 7(b). The specimen is resolution test patterns made of 0.5 μm-thick tantalum that were also fabricated at NTT-AT Nanofabrication by the same process as that of the FZP. The design feature of line and spacepatterns is shown in Figure 7(c). The fine patterns up to 0.2 μm were clearly seen in the measured images. The beam flux at the sample position was about 4 10 6 photons/s, and signal intensity in dark field mode was 2 10 5 photons/s. Although the design of test pattern has the 0.1 μmwide line and space patterns, the 0.1 μm widepatternsare not observed in the measure images, and a weak line is recognized at the right edge of pattern in the dark-field image where the 0.1 μm-wide line should be seen. The right edge of the 0.2 μm-line pattern is not observed in the darkfield image. In addition, in the bright-field image, there is a faint contrast pattern at the right side of the 0.2 μm-line pattern. From these results, we consider that the 0.1 μmwide pattern is provably collapsed or slanted and contacts to the neighboring 0.2 μm-wide line pattern. The 0.1 μm-wide line and space patterns are unfortunately imperfect in the measured portion of large test patterns. Acknowledgment The experiments were performed at the BL20XU in SPring- 8 under the approval of the Japan Synchrotron Radiation Research Institute (JASRI) (Proposal no. 2006A1562). References [1] Y. Suzuki, A. Takeuchi, H. Takano, and H. Takenaka, Performance test of fresnel zone plate with 50 nm outermost zone width in hard X-ray region, Japanese Journal of Applied Physics. Part 1, vol. 44, no. 4 A, pp. 1994 1998, 2005.

6 X-Ray Optics and Instrumentation [2] H. Mimura, H. Yumoto, S. Matsuyama et al., Efficient focusing of hard x rays to 25 nm by a total reflection mirror, Applied Physics Letters, vol. 90, no. 5, Article ID 051903, 3 pages, 2007. [3] O. Hignette, P. Cloetens, C. Morawe et al., Nanofocusing at ESRF using graded multilayer mirrors, in Synchrotron Radiation Instrumentation: 9th International Conference on Synchrotron Radiation Instrumentation, vol. 879 of AIP Conference Proceedings, pp. 792 795, June 2006. [4]C.G.Schroer,O.Kurapova,J.Patommeletal., Hardx-ray nanoprobe based on refractive x-ray lenses, Applied Physics Letters, vol. 87, no. 12, Article ID 124103, pp. 1 3, 2005. [5] H. C. Kang, H. Yan, R. P. Winarski et al., Focusing of hard x-rays to 16 nanometers with a multilayer Laue lens, Applied Physics Letters, vol. 92, no. 22, Article ID 221114, 3 pages, 2008. [6] G.-C. Yin, Y.-F. Song, M.-T. Tang et al., 30 nm resolution x- ray imaging at 8 kev using third order diffraction of a zone plate lens objective in a transmission microscope, Applied Physics Letters, vol. 89, no. 22, Article ID 221122, 3 pages, 2006. [7] Y. Feng, M. Feser, A. Lyon et al., Nanofabrication of high aspect ratio 24 nm x-ray zone plates for x-ray imaging applications, Journal of Vacuum Science and Technology B, vol. 25, no. 6, pp. 2004 2007, 2007. [8] Y. Suzuki and H. Toda, Advanced Tomographic Methods in Materials Research and Engineering, Oxford University Press, Oxford, UK, 2008, Section 7.1. [9] Y. Suzuki, Resolution limit of refractive lens and fresnel lens in X-ray region, Japanese Journal of Applied Physics. Part 1, vol. 43, no. 10, pp. 7311 7314, 2004. [10] M. Sekimoto, A. Ozawa, T. Ohkubo, H. Yoshihira, M. Kakuchi, and T. Tamura, X-Ray Microscopy II, Springer, Berlin, Germany, 1988. [11] A. Ozawa, T. Tamamura, T. Ishii, H. Yoshihara, and T. Kagoshima, Application of X-ray mask fabrication technologies to high resolution, large diameter Ta Fresnel zone plates, Microelectronic Engineering, vol. 35, no. 1 4, pp. 525 529, 1997. [12] D. Attwood, Soft X-Rays and Extreme Ultraviolet Radiation, Cambridge University Press, Cambridge, UK, 1999, Section 9. [13] M. Born and E. Wolf, Principles of Optics, Cambridge University Press, Cambridge, UK, 1999. [14] Y. Suzuki, K. Uesugi, N. Takimoto, et al., Construction and commissioning of a 248 m-long beamline with x-ray undulator light source, in Synchrotron Radiation Instrumentation: 8th International Conference on Synchrotron Radiation Instrumentation, vol. 705 of AIP Conference Proceedings, pp. 344 347, 2004. [15] Y. Suzuki, A. Takeuchi, H. Takano, T. Ohigashi, and H. Takenaka, Diffraction-limited microbeam with Fresnel zone plate optics in hard X-ray regions, in X-Ray Micro- and Nano- Focusing: Applications and Techniques II, Proceedings of the SPIE, pp. 74 84, San Diego, Calif, USA, July 2001. [16] Y. Suzuki and F. Uchida, Dark-field imaging in hard x-ray scanning microscopy, Review of Scientific Instruments, vol. 66, no. 2, pp. 1468 1470, 1995.