V-9927A DIGITAL MULTI-TONE GENERATOR

Similar documents
V-9963 DIGITAL FEEDBACK ELIMINATOR

V-136RTHF 36 ZONE TALKBACK INTERCOM/ PAGE CONTROL UNIT

V-119RT 19 STATION ROTARY-TONE INTERCOM

Built. Demanding. To Meet The Most. User Requirements. SWM Series Wall Mount Amplifiers

V-1109RTVA NINE ZONE PAGE CONTROL

MULTI-TONE GENERATOR V

Model 935A. Dual Tone Sender INSTRUCTION MANUAL

Master Reference Unit

Series 3000 Model R-107A

TONE ALERT RECEIVER MODEL 2TR9A. P.O. Box West Pacific. Lexington, NE 68850

Signal Isolation Module. Instruction Manual SIM

HydroLynx Systems, Inc.

Distribution Amplifiers 1

Series 500. Owner s Manual. Analog Transmitters by Data Industrial. Data Industrial. Data Industrial 2/95 PN 72806

User Instructions. Model PS-2001L. Power Supply. Model SPS Power Supply. Audiocom Intercom Systems Rev. A, 4/2001.

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

User s Guide Instructions for Installation and Operation

Interface Your Paging System with Virtually Any Telecom or IP Phone System

MODEL CM-30. Technical Practice November 2002 Issue 4. Service Observing System 1. GENERAL 2. DESIGN FEATURES CONTENTS: Model CM-30

Instruction Manual Model M Switch, DPDT, Manual Select

USER MANUAL MODEL Time Division Multiplexor, RS-232 (CTS TDM-V.24) SALES OFFICE (301) TECHNICAL SUPPORT (301)

X80 Activator. User's Manual. Version 1.1.

EQ-AMP60 60W Mixer Amplifier

CT-2 and CT-3 Channel Taggers OPERATION MANUAL

E7000, E7500, and E ma Analog Transmitters

Model 1791 VHF Radio User's Manual

Precision Frequency To Voltage Converter Card

Instruction Manual Model Upconverter

TLS-3A. Telephone Line Simulator. User Manual , Rev. B Covers Model TLS-3A-01

2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

Global Water Instrumentation, Inc.

Instruction Manual Model Upconverter

Instruction Sheet REB SERIES. Rotating Sliding Base REB18

USER MANUAL. MODEL 457B Seven Port Active Twinax Star Hub. SALES OFFICE (301) TECHNICAL SUPPORT (301)

Overview. Thank you for purchasing the Suhr Eclipse Dual Overdrive/Distortion Pedal.

Easy-Link Plus Version 2.2

INSTALLATION GUIDE. Video Balun Transceiver with fixed BNC for twisted pair operation with other balun transceivers or active receivers.

Broadband Step-Up Transformer. User Manual

Model RTX-12 Radio Modem

EMR CORPORATION N. 25th Avenue Phoenix, Arizona Toll Free: Tel: (623) Fax: (623)

OUR MISSION: TO PROVIDE HIGH QUALITY PRODUCTS, TECHNICAL EXCELLENCE & PRACTICAL ENGINEERING AT AN ECONOMICAL PRICE

SCADA and Telemetry Solutions. SCADALink IO900. Modular Wireless I/O System. User Manual Version V1.3 for SCADALink IO900 BENTEK SYSTEMS LTD

C5000 & C5000NF PULSE INITIATOR. Introduction

SSR-150xxx-40VL-12P-xC-xxxCS

Submittal 420I Converter

JMAA-1800HR15. Installation and Operation Instructions. 180w Performance Series Amplifier Kit For Harley RoadGlide/ Ultra

User s Guide ASSISTIVE LISTENING SYSTEMS

Classic Series Public Address Amplifiers C10 & C20 Models

Advanced Test Equipment Rentals ATEC (2832)

Model CC4041. CC Series Amplifier. Installation and Use Manual

Angular Rate Sensor. Owner's Manual

Smart-UPS On-Line Isolation and Step-Down Transformer SRT5KTF

AMERITRON RCS-12 AUTOMATIC ANTENNA SWITCH

Ordering Information. Ratchet Relay G4Q. Plug-in Models. Model Number Legend

DIGICELL ANYNET NETWORK ACCESS MODULE

INSTRUCTION MANUAL MODEL 2455T SUBCARRIER MODULATOR

JMAA-3600HR16-UL. Installation and Operation Instructions. Performance Series 360w RMS 4-Channel Amplifier Kit For Harley RoadGlide Ultra

RM24100A. *Maximum transmit power output levels and local radio frequency regulator bodies must be obeyed in the country of operation.

INSTRUCTION MANUAL MODEL 2779 SUBCARRIER MODULATOR

Smart-UPS RT. Isolation Transformer Models: SURT001 and SURT002 Isolation and Step-Down Transformer Models: SURT003 and SURT004.

MWC2-9. Operation Manual. MWC MHz Receiver with FM Radio Option. Radio. manmwc29_v7

Table of Contents. Overview... 3

About JFW Industries, Inc.

Ordering Information. Stepping Relay Unit G9B. Model Number Legend

Assistive Listening Systems. RX-6 User s Guide

Field Hub Installation Guide. P/N Rev. C 05/15

IRRIGATION 810-T PLUS TRANSMITTER GUIDE

Page/Talk Weatherproof Wall Stations Models MLW80 and MLW85

TECHNICAL. Interface Your Voice Paging System with Virtually Any Telecom or IP Phone System. FXI-1 FXO / FXS / Telecom Smart Paging Interface

USER MANUAL MODEL Parallel to Serial/ Serial to Parallel Interface Converter

AIS 300 Installation Instructions

CONNECT SYSTEMS INCORPORATED 1802 Eastman Ave., Suite 116 Ventura, Ca FLEX SERIES UNIVERSAL CONTROLLER

SA-505 Supervised Wireless Multi-Layer Repeater Installation Manual 1. General Description

Owner s Manual DKW-3 HT. Wireless VHF Microphone System

Performance Series 360w Amplifier Kit For Harley RoadGlide with Lower/Rear Speakers JMAA-3600HR15-RC

User s Guide Instructions for Installation and Operation

Shadow Measurement Sensor Large 30x1 mm Area. Beam Width (W) Note 2 BBS 30x1 mm <1000 in <39.

TECHNICAL MANUAL. SERIES AP5103 DIN-Rail DC Strain Gage Conditioner ISO 9001/AS9100

Using the USB Output Port to Charge a Device

Model CC4052. CC Series Amplifier. Installation and Use Manual

PIECAL 211 Automated RTD Calibrator Operating Instructions. Product Description. Practical Instrument Electronics

Advanced Test Equipment Rentals ATEC (2832)

TRANSDUCER IN-LINE AMPLIFIER

TRANSDUCER IN-LINE AMPLIFIER

PIECAL 311 Automated Universal RTD Calibrator Operating Instructions. Product Description

Broadband Current Probe Series Operation Manual

Programmable K-Factor Scaler B and Programming Software Kit B

Performance Series 360w 4-CH Amplifier Kit For Harley Street Glide with Lower/Rear Speakers JMAA-3600HC14-SG

Classic Series Amplifiers C35, C60, & C100 Models

SAS-562B Active Loop Antenna Operation Manual

RFTX-1 Installation Manual

SAS-563B Active Loop Antenna Operation Manual

SSR VL-12P-xC-NCS

RM24100D. Introduction. Features. 2.4GHz 100mW RS232 / RS485 / RS422 DSSS Radio Modem (IEEE compliant) Operating Manual English 1.

INSTALLATION INSTRUCTIONS

SX204. Headphone Amplifier. Symetrix. Owner s Manual

ER200 COMPACT EMERGENCY CRANK DIGITAL WEATHER ALERT RADIO OWNER S MANUAL

Instruction Manual. KP-1 Series 10M, 6M, 2M, 1-1/4M, 70 CM. IN-SHACK GaAsFET PRE-AMPLIFIER. MIRAGE KP-1 Pre-Amplifier

Video/Audio Transmission System Series VA700. (formerly Series DVL4A)

ACT-IR220Li/220LN IrDA Serial Port Adapter

Transcription:

VSP-V-9927A Issue 3 V-9927A DIGITAL MULTI-TONE GENERATOR TRODUCTION The V-9927A was designed with ease of installation and flexibility in mind. Connections are by screw terminals located on the edge of the PCB. The various options and tones are set using option blocks located inside the enclosure on the PC Board. The V-9927A is a microprocessor controlled multitone generator capable of producing a variety of tone signals for various applications. It is functional and backward compatible with the previous V-9927. (Double check all wiring as connections to the unit are different). This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of FCC Rules. These limits are designed to provide reasonable protection against harmful interference when this equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his/her own expense. SPECIFICATIONS Physical Dimensions: Nominal Input/Output Specifications: 8.2 H X 4.55 W X 2.3 D Input Impedance: 600 Ohms (20.83cm H x 11.56cm W x 5.84cm D) Output Impedance: Less than 4 Ohms Power Requirements: Min. Output Load Impedance: 20 Ohms -24VDC B Battery @ 100mA Audio Input: 0dBm Nominal Operating Environment: Max. Tone Output: > 1Vrms/single tone Temperature: 0-50 degrees C Weight: 1.5 lbs (.68 kg) Humidity: 0-85% non-condensing STALLATION Product is intended for wall mounting only. When mounting, open enclosure and remove circuit board. Screw back of enclosure to backboard near the telephone system common equipment. Snap circuit board back in place. Both mounting holes must be utilized to insure secure mounting of the unit. Make connections and set tones, using option blocks, as required for the specific application (Refer to Tone Table on page 2 for tone descriptions). Replace cover and plug in power supply. 1 947926

OPERATION All Tones (except Code Call) Operation of the V-9927A is accomplished by applying a connection between the COM (Common) terminal on the terminal block and the desired tone # (1-8). The Tone selected by terminal #1 has priority over others. If multiple tone inputs are being used, it is possible to sequence tones by closing the appropriate contacts in the desired sequence. However, Tone #1 will always be placed first on the list when it has been activated. If multiple tones are selected at the same time, the LOWEST tone number will have priority. If the lowest contact is open, then the next lowest tone number will be activated. When a Tone is activated the PUT source will be faded out in 0.75 seconds if P5 is out or will be faded out in 0.25 seconds if P5 is. The V-9927A has a buffer for 32 tones. If more than 32 tones are entered within a short period, the V-9927A will drop the last tone entered. Figure 2 illustrates several of the ways the V-9927A can be used with other Valcom equipment. Code Call Operation When the V-9927A is connected to the V-9923A code call unit, the V-9927A will respond to the contact closure inputs and issue single chimes in response (See Figure 2). At the beginning of a Code Call sequence, the PUT source will be faded down about 6dB. It will remain at this level until the CODE CALL sequence has completed (including the interdigit time). At that time, the PUT source will be faded back up to normal level. When using the CODE CALL option with other tone options, the CODE CALL may be interrupted to place other tones in the sequence (including Tone #1 with higher priority). However, the CODE CALL may be out of sequence for the period that this occur. CONNECTION ON JP1 COM - TONE 1 COM - TONE 2 COM - TONE 3 COM - TONE 4 COM - TONE 5 COM - TONE 6 COM - TONE 7 COM - TONE 8 COM - TONE 1 COM - TONE 2 COM - TONE 3 COM - TONE 4 COM - TONE 5 COM - TONE 6 COM - TONE 7 COM - TONE 8 OPTION BLOCK P3 TONE TABLE DESCRIPTION * WHOOP, 698 Hz, 3.9 sec (approx.)/cycle 2 cycle min. * DUAL CHIME, 880 Hz/698 Hz * BURST, 880 Hz, 1/2 sec on, 2 min. * STEADY, 880 Hz, 3 sec. min. TeleBell 986/784 Hz, 11/sec, 10 minimum Chimes, 986, 784, 659, 523 Hz order Chimes, 880, 698, 587, 494 Hz order CODE CALL CHIME, 784 Hz (V-9923A standard) > SIREN, 659 Hz, center 1 cycle approx. 0.3 Hz > WHOOP (yelp) 659 Hz, 2.5 Hz, 4 min. > WARBLE, 494/986 Hz, 6 Hz rate > STEADY 698 Hz, 1 sec. minimum > BURST (pulse), 494 Hz, 4.5 Hz rate Chimes 659/784 Hz Chimes 986/784 Hz CODE CALL CHIME, 784 Hz (V-9923A Standard) NOTE: * denotes V-9927 compatible tones > denotes USA Standard Immediate Evacuation signal for industrial areas 2 947926

Option Blocks (Jumpers shown in factory default setting)) FIGURE 1 P6 P5 UNMUTE P4 P1 BURST MUTE CONT P2 P3 Adjust for Desired Output Level Green LED on when power is present TONE BANK SELECT T1 TONE LVL POWER ON Compatibility with the V-9927 Set P3 to "" position Set P1 for BURST or CONT as required Set P4 to UNMUTE Set P5 to "" TONE inputs 1-4 correspond to WHOOP, CHIME, BURST, and STEADY. CODE CALL is available on TONE input 8. T2 JP1 1 2 3 4 5 6 7 8 COM SIGNAL COM TONES Connect COM to Desired Tone Signal In (Optional) Relay Contact SIGNAL GND -24V Signal Out Power Supply -24VDC (-) (+) Description of Jumpers P1 (BURST/CONT) - Sets the mode of the V-9927A. The BURST function allows one (1) tone (or sequence) for each closure of the TONES input. The CONT function is continuous; the tone (or sequence) will repeat while the closure on the TONES input (1-8) remains activated. P3 (TONE BANK Select; /) - Activates tones. Refer to the Tone Table (page 2) to determine jumper placement for the desired tones. P4 (UNMUTE/MUTE) - Determines if SIGNAL is muted or unmuted. With UNMUTE selected, the signal returns after completion of a designated tone (or sequence) even if the relay on the TONES input (1-8) remains connected. With MUTE selected, the signal remains off after completion of tones even if the relay on the TONES input (1-8) is connected. P5 (/) - Determines the fadeout duration of the Input Source. The PUT source will be faded out in 0.75 seconds if P5 is or will be faded out in 0.25 seconds if P5 is. P2 & P6 - Not used on this version. 3 947926

. 1/ 7 4-6 ; 2 1+ ) 7 5-5. 4 6 0-7 5 1+ 5 7 4 + - & + * / 2 7 6 + J=? J+ I K HA I B H)? JEL = JE C 6 A I + - + 6 -, 6 * ) + / 4 7, 7 5 1+ 2 7 6 8 =? A M = O A A F = C A? JH H A M = O HJM M = O K JE A F = C A? JH 7 5 1+ 5 7 4 + - 5 9 16 + 0 -, 2 7 6 8 ' '! ) +, - + ) & + +, - + ) + 0 - / - - 4 ) 6 7 F J # A 9 = O ) F EBEA @ 5 F A = A HI 2 ) / - 2 4 6 4 -. ) 8 ) + 2 ) / - + 6 4 + J=? J+ I K HA I B H)? JEL = JE C 6 A I & + 7 F J # A 9 = O ) F EBEA @ 5 F A = A HI + - + 6 -, 6 ) -. ) - 9 ) ; 2 ) / / 5 ; 5 6 - TECHNICAL ASSISTANCE When trouble is reported, verify the unit in question is turned on (the green ON LED should be observed) and all connections are secure. Assistance in troubleshooting is available from the factory. When calling, you should have a VOM available and be calling from the job site. Call (540) 427-3900 and ask for Technical Support, or call (540) 427-6000 for Valcom 24-hour Automated Support or visit our website at http://www.valcom.com. Valcom equipment is not field repairable. Valcom maintains service facilities in Roanoke, VA. Should repairs be necessary, attach a tag to the unit clearly stating company name, address, phone number, contact person, and the nature of the problem. Send the unit to: Valcom, Inc. Repair & Return Dept. 5614 Hollins Road Roanoke, VA 24019-5056 4 947926

VALCOM LIMITED WARRANTY Valcom, Inc. warrants its products to be free from detects in materials and workmanship under conditions of normal use and service for a period of one year from the date of shipment. The obligation under this warranty shall be limited to the replacement, repair or refund of any such defective device within the warranty period, provided that: 1. inspection by Valcom, Inc. indicates the validity of the claim, 2. the defect is not the result of damage, misuse, or negligence after the original shipment, 3. the product has not been altered in any way or repaired by others and that factory sealed units are unopened (A service charge plus parts and labor will be applied to units defaced or physically damaged), 4. freight charges for the return of products to Valcom are prepaid, 5. all units out of warranty are subject to a service charge. The service charge will cover minor repairs (Major repairs will be subject to additional charges for parts and labor). This warranty is in lieu of and excludes all other warranties, expressed or implied, and in no event shall Valcom, Inc. be liable for any anticipated profits, consequential damages, loss of time or other losses incurred by the buyer in connection with the purchase, operation or use of the product. This warranty specifically excludes damage incurred in shipment. In the event a product is received in damaged condition, the carrier should be notified immediately. Claims for such damage should be filed with the carrier involved in accordance with the F.O.B. point. Headquarters Valcom, Inc. 1111 Industry Avenue Roanoke, VA 24013 Phone: (540) 427-3900 FAX: (540) 427-3517 In Canada: CMX Corporation 35 Vank Kirk Drive #11 and 12 Brampton, Ontario L7A1A5 Phone: (905) 456-1072 FAX: (905) 456-2269 5 947926