TIGHTENING TORQUE ON WOODEN CORE CLAMP (Nm) (STEEL FASTENER) 1 M M M M M

Similar documents
SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

Transformer Winding Design. The Design and Performance of Circular Disc, Helical and Layer Windings for Power Transformer Applications

OIL-IMMERSED ARC-SUPPRESSION COILS

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

Basic Principles and Operation of Transformer

HOW TO SAFE GUARD THE TRANSFORMER..???

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

POWER TRANSFORMERS CATALOGUE

51-SDMS-04 SPECIFICATIONS FOR. DISTRIBUTION TRANSFORMERS UP TO 36 kv WITH ALUMINUM WINDINGS FOR DUAL SECONDARY 400/230 V AND 230/133 V

Brown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS

7. INSPECTION AND TEST PROCEDURES

51-SDMS-02 SPECIFICATIONS FOR DISTRIBUTION TRANSFORMERS UP TO 36KV 400/230 VOLTS

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1

CAST RESIN DRY TRANSFORMER

Electrical Design Process

Efacec work every day to anticipate solutions for a sustainable world in the new energy era.

POWER TRANSFORMER SPECIFICATION, DESIGN, QUALITY CONTROL AND TESTING 18 MARCH 2009

Hands-On Transformer Testing and Maintenance

CONSULTANT PROCEDURES & DESIGN GUIDELINES Liquid-Filled Utility Transformers UNIVERSITY OF MISSOURI

Regional Technical Seminar SHORT CIRCUIT FORCES

RESIDUAL LIFE ASSESSMENT OF GENERATOR TRANSFORMERS IN OLD HYDRO POWER PLANTS

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

TRANSFORMER OPERATIONAL PRINCIPLES, SELECTION & TROUBLESHOOTING

Transformers handling and transport

CHAPTER 2 ELECTROMAGNETIC FORCE AND DEFORMATION

DEFERRING REPLACEMENT OF A 600 MVA, 345GRD Y/138GRD Y/ 13.8 kv SHELL TYPE WESTINGHOUSE AUTOTRANSFORMER

Power transformers for Network, Rectifiers, Furnace

Distribution/Substation Transformer

Modeling Distribution Component Deterioration: An application to Transformer Insulation. A.U. Adoghe 1, a, C.O.A. Awosope 2,b and S.A.

TMC Transformers TMC

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

Shunt Reactors. Global Top Energy, Machinery & Plant Solution Provider

Copper Core & Coil Transformer

Transformer Protection

Introduction. Centrado leading-edge transformer. Introduction

CHAPTER 3 SHORT CIRCUIT WITHSTAND CAPABILITY OF POWER TRANSFORMERS

Power Transformer Condition Assessment Based on Standard Diagnosis

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

AS/NZS :2013 (IEC , , MOD)

IMPORTANCE OF INSULATION RESISTANCE

Howard Smart Transformer Specification Guide

MODERN POWER TRANSFORMER PRACTICE BIBLIOGRAPHY

Diagnostic testing of cast resin transformers

Transformer Factory Testing

TRANSFORMER TECHNOLOGY GPT

PES & IAS NY Chapter And NY LMAG June 23 rd, 2015

HIGH VOLTAGE ENGINEERING(FEEE6402) LECTURER-24

Transformer Testing & Maintenance Fundamentals. AVO Training Institute, Inc. 2018

save energy, it is precious SYNERGY transformers Mfg. of all types of Distribution / Power & Furnace Transformers

NSP/ 007 / 006 Guidance on Substation Design: Transformer Transport, Delivery and Installation

Distribution Equipments - Technology and Applications. Training Module for DISTRIBUTION TRANSFORMER

Cholla T809 Condition Assessment Report Provided by students of Northern Arizona University with the support of Arizona Public Service

Specialists in HV and MV test and diagnostics. Testing in Substations

Case Studies of Electric Power Equipment Diagnostics Using Acoustic Emission

Western Mining Electric Association San Antonio TX Layer vs. Disk Windings Discussion NOVEMBER 15, SPX Transformer Solutions, Inc.

General Electricity Company of Libya

Single & Three Phase Transformers SAMPLE. Learner Workbook. Version 1. Training and Education Support Industry Skills Unit Meadowbank

POWER TRANSFORMER. Failure Analysis & Troubleshooting. H.H. Sheik Sultan Tower (0) Floor Corniche Street Abu Dhabi U.A.E

SPECIFICATION FOR 11 KV CLASS, 24/15.7, 30/19.7 & 45/29.5 AMPS SPECIAL DESIGN TRANSFORMERS.

Group F : Sl. No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS. Table : A

CONDITIONS FOR A TENTATIVE APROVAL FOR CONNECTION OF TRANSFORMERS

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS. IR Values are to be read on the megger by meggering the Power transformer

Understanding the Value of Electrical Testing for Power Transformers. Charles Sweetser, OMICRON electronics Corp. USA

Power Transformers Basics

Prolific Systems & Technologies Pvt. Ltd. CORE DETAILS. CENTRE Figure - II L-2 X Y Wt-2

POWER TRANSFORMERS TMPNG-SESH SERIES FOR OIL PUMPS ENERGY OF YOUR FUTURE

About us. Vision. To lead our field in innovation, quality and customer service.

Transformers TRANS FORM ERS

Neutral Earthing. For permanent or temporary neutral earthing in HV systems

Regional Technical Seminar SHORT CIRCUIT FORCES

Advancements in online partial discharge monitoring and assessment of MV through EHV Substation assets

S. C. Electric Cooperative s Specification for a Single-Phase, Single Bushing Overhead Distribution Transformer (Revised 10/2013)

CASE STUDY- FAULT IN POWER TRANSFORMER AT LOKTAK POWER STATION. - S K Mishra & S K Das NHPC Ltd O&M Division

Discipline Electrical Testing Issue Date Certificate Number T-2837 Valid Until Last Amended on - Page 1 of 6 LOCATION 1

SOUTHERN ELECTRICITY SUPPLY COMPANY OF ODISHA LIMITED (SOUTHCO UTILITY)

This document is a preview generated by EVS

nical catalogue Tech

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET

Title Substation Auxiliary Transformer from Rectifier Transformer Secondary. Reference Number PDS 01 (RIC Standard: EP SP)

TRAFO ELECTRIC P. LTD.

Cork Institute of Technology. Autumn 2008 Electrical Energy Systems (Time: 3 Hours)

COMPANY PROFILE... 1 QUALITY CERTIFICATES... 2 APPLICATIONS... 3

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

MEDIUM VOLTAGE PRODUCT. PARAMETERS GUIDE How to specify the indoor instrument transformers correctly

Title: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS

QUESTIONNAIRE for Wind Farm Power Stations only

Armoured Power and Control Cables Fire Resistant

VI 3 - i TABLE OF CONTENTS

شركة كهرباء محافظة القدس المساهمة المحدودة JERUSALEM DISTRICT ELECTRICITY CO. LTD.

SPECIFICATION No SS-135/ kv METAL OXIDE SURGE ARRESTERS WITHOUT GAPS

Power Frequency Withstand Voltage On-site testing of 400 kv GIS

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

and cured to reduce hot spots and seal out moisture. The assembly shall be installed on vibration-absorbing pads.

Power Cables and their Application

Industrial Applications

EE059: Transformer Operation, Maintenance, Diagnosis & Testing

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

CONTENTS. 1. Introduction Generating Stations 9 40

Transformer Technology Seminar What to consider at Design Reviews

Transcription:

SL. NO NOMINAL DIAMETER "D" mm GASKETED JOINT (Nm) WOODEN CORE CLAMP (Nm) STEEL FIXING STUD FOR BUSHING (Nm) BUSHING STEM (Nm) (BRASS /COPPER) COPPER BUSBAR (Nm) 1 M6 5 - - - - 2 M8 12 - - 10-3 M10 22 22 15-25 4 M12 38 38 25 13 40 5 M16 90 90 40-90 6 M20 176 176-30 - 7 M24 304 304 - - - 8 M42 - - - 110-9 M48 - - - 180 -

No- Loss loss loss Impedance Voltage (%) Impedance Voltage (%) 10 16 13 55 141 9 14.4 12.5 20 15 60 153.6 9 14.4 16 25 17 65 158.7 10 15.6 20 31.5 20 70 173.6 10 12.6 25 40 24 80 204.8 10 16 31.5 50 28 86 216.7 10 15.9 40 63 35 102 253.0 10 15.8 50 80 41 110 281.6 10 16 63 100 49 126 317.5 10 15.9 Dimension LxWxH (mm) Total Oil Shipping 10 16 5000x2650x4700 36,000 12,000 25,000 12.5 20 5200x2700x4800 40,000 12,500 28,000 16 25 5300x2750x5000 45,000 13,500 21,500 20 31.5 5400x2800x5200 51,000 14,000 35,700 25 40 5500x2900x5300 58,000 14,500 40,600 31.5 50 5600x2950x5400 65,000 17,000 45,000 40 63 5700x3000x5500 75,000 18,000 52,500 50 80 5800x3100x5600 90,000 20,500 63,000 63 100 5900x3200x5700 100,000 25,500 70,000

SERVICE WHAT KEEPS YOUR TRANSFORMER OPERATIONAL? PAPER Paper is what keeps your transformer operating. Paper provides the mechanical strength holding this giant transformer together! It provides Mechanical strength Dielectric strength Dielectric spacing MYTH The Paper in a transformer is under no stress since transformers have no moving parts FACT Other than in load tap changers and regulating transformers, a transformer has no functional, mechanically moving parts, but the paper is under constant stress due to Mechanical vibration Switching surges Line surges Limited short circuits The paper wrapping and spacers withstand this movement when your transformer is new. As your transformer ages, it loses this ability. IEEE defines your transformer s end of life when there is a 75% loss in paper tensile strength. Beyond this point your transformer may not reliably withstand the next surge load or short circuit. WHAT PROVIDES DIELECTRIC STRENGTH, COOLING AND PROTECTS THE PAPER INSULATION? MINERAL OIL Mineral Oil Provides Dielectric Strength Cooling Protection to the Paper When the oil is not providing one of these functions, servicing will be required to assure Maximum Transformer Life. Before the oils ability to provide Dielectric Strength and Cooling is reduced and before oxidizing compounds become established and decay the paper, the oil must be maintained in order that the Transformer Life is not reduced. Oil is an organic compound, which naturally oxidizes and decays. Oil in a Transformer is encouraged to oxidize by the presence of acids, moisture, gases, lacquers and other contaminants. The same oxidants which exist in the oil also take up residence in the paper since the paper acts like a filter and absorb these decaying products, in turn destroying its own insulating properties! SLUDGES If allowed to continue unchecked, oil decay products will form sludge deposit in the transformer which acts to trap heat in the transformer, degrades the insulation and reduces dielectric gaps increasing the risk of failure. Sludge can only be removed by Hot Oil Cleaning, preferably when the Transformer is energized. Filter all equipment offers the facility to redissolve oil decay products and remove them in order that clean as new Oil is returned to the transformer. This provides a thorough cleaning of the transformer internals, the insulating papers, the cooling fins and ducts by providing a continuous redissolving action of the oil decay products. Since the process also cleans the transformer internals, not just the oil, the ageing process is very much reduced providing for Extended Transformer Life.

Table 1 Recognized minimum values of short-circuit impedance for transformers with two separate windings Power kva Up to 630 631 to 1 250 1 251 to 2 500 2 501 to 6 300 6 301 to 25 000 25 001 to 40 000 40 001 to 63 000 63 001 to 100 000 Above 100 000 Short-circuit impedance at rated current Minimum short-circuit impedance % 4,0 5,0 6,0 7,0 8,0 10,0 11,0 12,5 >12,5 NOTE 1 Values for rated greater than 100 000 kva are generally subjected to agreement between manufacturer and purchaser. NOTE 2 In case of single-phase units connected to from a three-phase bank, the value of rated applies to three-phase bank rating. 3.2.2.4 The short-circuit apparent of the system at the transformer location should be specified by the purchaser in his enquiry in order to obtain the value of the symmetrical shortcircuit current to be used for the design and tests. If the short-circuit apparent of the system is not specified, the values given in table 2 shall be used. Highest voltage for equipment, Um kv 7,2; 12; 17,5 and 24 36 52 and 72,5 100 and 123 145 and 170 245 300 362 420 525 765 Table 2 - short-circuit apparent of the system Short-circuit apparent MVA Current European practice Current North American practice 500 1 000 3 000 6 000 10 000 20 000 30 000 35 000 40 000 60 000 83 500 500 1 500 5 000 15 000 15 000 25 000 30 000 35 000 40 000 60 000 83 500 NOTE : If not specified, a valve between 1 and 3 should be considered for the ratio of zero-sequence to positive-sequence impedance of the system. 3.2.2.5 For transformers with two separate windings, normally only the three-phase short circuit is taken into account, as the consideration of this case is substantially adequate to cover also the other possible types of fault (exception is made in the special case considered in the note to 3.2.5).

NOTE: In the case of winding in zigzag connection, the single-line-to-earth fault current may reach values higher than the three-phase short-circuits current. However, these high values are limited, in the two limbs concerned, to a half of the coil and furthermore the currents in the other star-connected winding are lower than for a three-phase short circuit. Electro dynamic hazard to the winding assembly may be higher either at three- or single-phase short circuit depending on the winding design. The manufacturer and the purchaser should agree which kind of short circuit is to be considered.