Vibrotactile Device for Optimizing Skin Response to Vibration Abstract Motivation

Similar documents
Vibrotactile Device for Optimizing Skin Response to Vibration

Vibrotactile Device for Optimizing Skin Response to Vibration

A Pilot Study: Introduction of Time-domain Segment to Intensity-based Perception Model of High-frequency Vibration

Speech, Hearing and Language: work in progress. Volume 12

Kistler portable triaxial Force Plate

Vibrotactile Apparent Movement by DC Motors and Voice-coil Tactors

Acoustic Resonance Lab

Shape Memory Alloy Actuator Controller Design for Tactile Displays

New Long Stroke Vibration Shaker Design using Linear Motor Technology

HAPTIC A PROMISING NEW SOLUTION FOR AN ADVANCED HUMAN-MACHINE INTERFACE

the human chapter 1 Traffic lights the human User-centred Design Light Vision part 1 (modified extract for AISD 2005) Information i/o

Evaluation of Five-finger Haptic Communication with Network Delay

Proprioception & force sensing

Auditory-Tactile Interaction Using Digital Signal Processing In Musical Instruments

Haptic User Interfaces Fall Contents TACTILE SENSING & FEEDBACK. Tactile sensing. Tactile sensing. Mechanoreceptors 2/3. Mechanoreceptors 1/3

Effect of Remote Vibrotactile Noise on Pinch Force Maintenance Ability and Brain Activity

The Integument Laboratory

Exploring Surround Haptics Displays

Reliability Studies of the Nozzle/Piezo Units for the WASA-at-COSY Pellet Target

Design of New Micro Actuator for Tactile Display

Touch & Haptics. Touch & High Information Transfer Rate. Modern Haptics. Human. Haptics

ALM473 DUAL MONO \ STEREO AUDIO LEVEL MASTER OPERATION MANUAL IB

TACTILE SENSING & FEEDBACK

Here I present more details about the methods of the experiments which are. described in the main text, and describe two additional examinations which

from signals to sources asa-lab turnkey solution for ERP research

Lecture 8: Tactile devices

Force versus Frequency Figure 1.

Somatosensory Reception. Somatosensory Reception

School of Instrument Science and Opto-electronics Engineering, Hefei University of Technology, Hefei, China 2

M.ENG PROJECT: TOADFISH BEHAVIORAL ROBOT FOR FISH AGGRESSION STUDY

Force Amplitude Control Algorithm on Fatigue Test with Sine Waveform

Application Note: Precision Displacement Test Stand Rev A

The Effect of Frequency Shifting on Audio-Tactile Conversion for Enriching Musical Experience

Fast Tip/Tilt Platform

Haptic Perception & Human Response to Vibrations

SAT pickup arms - discussions on some design aspects

D.C. Emmony, M.W. Godfrey and R.G. White

Lecture 7: Human haptics

Earthquake Resistance Test Specifications for Communications Equipment

PREDICTION OF FINGER FLEXION FROM ELECTROCORTICOGRAPHY DATA

Investigation on Sensor Fault Effects of Piezoelectric Transducers on Wave Propagation and Impedance Measurements

Remote Tactile Transmission with Time Delay for Robotic Master Slave Systems

Touch. Touch & the somatic senses. Josh McDermott May 13,

Research on Simultaneous Impact of Hand Arm and Whole-Body Vibration

Large Signal Displacement Measurement with an MTI Photonic Sensor Rev B

Chapter 30: Principles of Active Vibration Control: Piezoelectric Accelerometers

Phase Diagram. for hand-held contact microphones, phonograph turntable, mixing board and equalizer

IMS-2019 Student Design Competition Instructions

Tactile Actuators Using SMA Micro-wires and the Generation of Texture Sensation from Images

Audio. Audio. DB1100 Active DI Box CABLES. Hot Wires Microphone Cables. Hot Wires Instrument Cables. Hot Wires Pro Instrument Cables

Examination of Microphonic Effects in SRF Cavities

Lavalier microphone for smartphones USER MANUAL

Simple Feedback Structure of Active Noise Control in a Duct

PSpice Simulation of Vibrating Sample Magnetometer Circuitry

First Time User Manual

PA8HF power amplifier Operating guide

M-227 DC-Mike Actuators

Expression of 2DOF Fingertip Traction with 1DOF Lateral Skin Stretch

ACCUMEASURE. Non-contact Capacitance Position Measurement with Nanometer Accuracy. A worldwide leader in precision measurement solutions

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE. ISO-STIM 01D STIMULUS ISOLATION UNIT ±100 V / ±10 ma, bipolar output

S. Ghosh On behalf of Linac, IFR, Cryogenics, RF and beam transport group members. Inter University Accelerator Centre New Delhi India

1712. Experimental study on high frequency chatter attenuation in 2-D vibration assisted micro milling process

Device Interconnection

MaxBit Professional Crimping Tool

FINGER MOVEMENT DETECTION USING INFRARED SIGNALS

Virtual Chromatic Percussions Simulated by Pseudo-Haptic and Vibrotactile Feedback

Tactile sensing system using electro-tactile feedback

Sensation and Perception. Sensation. Sensory Receptors. Sensation. General Properties of Sensory Systems

Applied Anthropometry, Work-Space Design Part I Anthropometry (Chapter 13)

Operation Manual. Congratulations on purchasing your high quality AIMS Power pure sine inverter!

CONSTRUCTION OF A QUASI STATIC C V TEST STATION. Randall 3. Mason 5th Year Microelectronic Engineering Student Rochester Institute of Technology

PDN Probes. P2100A/P2101A Data Sheet. 1-Port and 2-Port 50 ohm Passive Probes

ME 15 and ME 30 OPERATING AND SERVICE MANUAL

Void Reduction in Reflow Soldering Processes by Sweep Stimulation of PCB Substrate

Tactile letter recognition under different modes of stimulus presentation*

REPORT ON THE RESEARCH WORK

FIRST MEASUREMENTS FROM A NEW BROADBAND VIBROTHERMOGRAPHY MEASUREMENT SYSTEM

TAKE THE MYSTERY OUT OF PROBING. 7 Common Oscilloscope Probing Pitfalls to Avoid

Testing in a Combined Vibration and Acceleration Environment

Rowan University Freshman Clinic I Lab Project 2 The Operational Amplifier (Op Amp)

Texture recognition using force sensitive resistors

Final Project: Sound Source Localization

TD250 6 Channel 250V Amplifier Manual and Specifications

Sensation. Our sensory and perceptual processes work together to help us sort out complext processes

Detection of external stimuli Response to the stimuli Transmission of the response to the brain

Multifrequency Doppler Signatures of Human Activities

VCSO Mechanical Shock Compensation

A Miniaturized Ultrasonic Power Delivery System Tzu-Chieh Chou, Ramkumar Subramanian, Jiwoong Park, and Patrick P. Mercier

ELR 4202C Project: Finger Pulse Display Module

Lab 1. Resonance and Wireless Energy Transfer Physics Enhancement Programme Department of Physics, Hong Kong Baptist University

Available online at ScienceDirect. Procedia Computer Science 79 (2016 )

Chapter 5. Signal Analysis. 5.1 Denoising fiber optic sensor signal

Electrical noise in the OR

III. Publication III. c 2005 Toni Hirvonen.

Wilcoxon Research PA8HF power amplifier Operating guide

Maximizing LPM Accuracy AN 25

(a) What is the tension in the rope? (b) With what frequency must the rope vibrate to create a traveling wave with a wavelength of 2m?

A New Low-Cost Bionic Hand

Lauren Gresko, Elliott Williams, Elaine McVay Final Project Proposal 9. April Analog Synthesizer. Motivation

Large Signal Displacement Measurement With Piezo Jena vibrometer Rev A

Transcription:

Vibrotactile Device for Optimizing Skin Response to Vibration Kou, W. McGuire, J. Meyer, A. Wang, A. Department of Biomedical Engineering, University of Wisconsin-Madison Abstract It is important to understand stochastic resonance on the hands in order to prove how it effectively enhances vibrosensory perception. To do this, an MR-compatible tactor is needed to provide a vibration stimulus to the hand during an MRI of the brain. The key design requirements of the device are that it must run at a frequency range of 30-300 Hz, and be small enough to fit on the subject s finger while maintaining a 1 mm thickness. In order to achieve these requirements, three design options were evaluated: solenoid, piezoelectric, and pneumatic. Of these three options, the piezoelectric device was determined to be the best-suited design. Using a 741 operational amplifier circuit, a random audio signal was amplified to drive the piezoelectric circuit. Testing of the device consisted of circuit gain and amplitude tests, along with a perception test of the fingers on both left and right hands. The index and thumb fingers were determined to be the most sensitive to vibrations. Future work is to be conducted by Professor Na Jin Seo to test the piezo buzzer s displacement, along with stochastic resonance in an MRI to observe brain function. Motivation Falling from ladders or scaffolds is of the leading causes of workplace injuries and fatalities. Professor Na Jin Seo of UW-Milwaukee is examining methods of improving reaction time to vibrations to possibly reduce the number of fall-related injuries. According to previous studies, the skin sensation of hand is believed to be the first available sensory cue for workers to detect and react to the fall initiation. On average, healthy young people took about 100 ms to arrest and stabilize their bodies when sudden forces were applied to the ladder [1]. Out of the 100 ms period, approximately 40 ms was because of the delay in the brain cortical reflex loop, while the other 60 ms was mainly from the delay of hand skin receptors to detect the change in contact force [1]. If this 60 ms time period could be reduced by decreasing the amount of time skin receptors used for detecting the change in force, then the person s ability to rescue the fall could be greatly enhanced [1]. The principle the Professor Seo is exploring for improving vibration perception is called stochastic resonance, which is a phenomenon that occurs when a sub-threshold signal is enhanced by the presence of noise [2]. Stochastic resonance can assist a sensing system in detecting a signal by adding a predetermined amount of noise. This noise has the same modality as the signal, but does not contain significant information to the system, or is sub-threshold. When adequate noise is added to the signal, it increases the amplitude of the signal, which can bring it above threshold. In most cases, it is preferred to eliminate noise from a signal; however, in the case of sensing small vibrations, an outside noise is helpful for bringing the signal above threshold and allowing the body to sense the small vibrations.

Setup The goal of this project is to improve the workers response time by stimulating their sense of touch through vibrations in their hands. The device must be MR-compatible in order to analyze brain activity during the stimulus to the hand. The overall goal is to prove that a continuous stimulus on the hand can improve the range of sensory frequency perception. Client specifications also include that the device must operate at a vibration frequency of 30-300 Hz (the optimal frequency for the vibration receptors in the hands). Ideally, the stimulator device will fit on the tip of the subject s finger, having an outside diameter of 2 cm, and a thickness of 1 mm. A diameter of 2 cm was calculated the Digit 2, Distal Interphalangal joint breath for the 95 th percentile male using anthropometric survey data from the U.S. Army [3]. Based on the above design criteria, a piezoelectric system for vibration was chosen to provide adequate noise for stochastic resonance. When a mechanical force is applied to some solid materials, an electrical charge will form as a result. This is known as piezoelectricity [4]. The piezoelectric vibrator chosen was a Digikey (Part number 668-1004-ND) piezoelectric buzzer, which is made from MRI-compatible materials; the device has a thickness of less than 1 mm, and an outside diameter of 2 cm. The final device assembly can be seen in Figure 1. Figure 1: Final assembly. The audio cord (black) supplies the input waveform from the source, the batteries and circuitry rest in the housing, the 50 ft shielded cable (white) runs from the control room to the MRI room, supplying the amplified waveform, piezo attached to shielded cable, and finger holder (white, center of picture) designed to stabilize piezo on subjects finger. Stochastic resonance requires that the vibration signal must be randomly changing within the range of 30-300 Hz, which was most easily achieved through the use of an audio signal to drive the vibrator. The audio signal (from a computer or mp3 player) was then amplified using a 741 operational amplifier circuit. The audio source and circuit are to be located in the control room for the MRI, where ferrous materials are not a problem. The signal is then passed to the piezoelectric buzzer through a 50-ft. shielded wire into the MRI room.

Testing The gain of the circuit was experimentally determined in order to obtain exact values for the output voltage to the piezo from the circuit. Using the random frequency audio file, the peak-to-peak voltages from a computer (Apple MacBook Pro was used) were measured and served as the input voltages for the 741 operation amplifier circuit. The volume of the computer was slowly increased in order to increase the voltages from computer, and that increasing input voltages were matched with the corresponding output voltages generated by op-amp circuit to produce Figure 2. After determining the output values for the device, perception testing was conducted to determine the most sensitive areas of the hand. This information will be useful for Professor Seo when determining the best location for the piezoelectric buzzer when testing stochastic resonance. It is ideal for testing to be done on the most sensitive areas of the hand because these areas will sense vibrations earliest, and thus would be the best for improvement of reaction time. Data The results of the gain testing for the 741 op-amp circuit indicated a gain of approximately 4.6. The gain was relatively linear with an increase in the input voltage, and had an R 2 value of.988. Figure 2: Correlation of input voltage from audio source to voltage at piezo. The perception tests indicated that the left and right hands of test subjects had approximately the same level of sensitivity, as shown in Figure 3. Although the displacement of vibration was not determined by these tests, the most sensitive regions of the hand could still be determined assuming that the displacement was directly related to the voltage input for the piezo.

Figure 3: Perception voltages for the Left and Right hands of test subjects. Table 1: Average Perception Rankings for Digits on Left and Right Hand (lower voltage level indicates a higher perception for the digit). Errors in this testing may have resulted from Digit Left Hand Right Hand 2 (Index) 1.31 V (1) 1.32 V (2) 1 (Thumb) 1.33 V (2) 1.28 V (1) 5 (Pinky) 1.42 V (4) 1.42 V (3) 3 (Middle) 1.40 V (3) 1.52 V (5) 4 (Ring) 1.57 V (5) 1.48 V (4) Analysis The gain of the circuit was determined to be approximately 4.6; however, the theoretical gain of the system was calculated to be 5.5. The variances in the gain could have been due to a faulty 741 op-amp, which could deplete the gain. Another source for this variance could have been due to difficulties in obtaining accurate amplitude measurements from the randomly changing audio signal. The amplitude is constantly changing, and the voltage output measured could have varied enough to skew the gain of the system at the moments when the measurements were taken. The hand sensitivity testing, as shown in Table 1, indicated that the index and thumb digits of the hand were the most sensitive areas. The data from these tests was compared with a previous project conducted by N. Alawieh at UW-Madison to determine the most sensitive regions of the hand. A diagram, shown in Figure 4, of the most sensitive regions of the hand was modified from this project in order to properly indicate the regions that Professor Seo should conduct testing on.

Figure 4: Map of hand sensitivities based on applied tactor voltage: Notice that there is an increased sensitivity a the tips of the fingers [Adapted from 5]. These tests also indicate that different test subjects will have different sensory levels, so it is important that the device can precisely adjust the level of actuation to accommodate various perception levels. This is something that is easily achieved through this device because the amplitude is changed by simply adjusting the volume of the audio source. The average perception rankings for the piezoelectric sensitivity testing are shown in Table 1, and indicate very similar results to the previously determined sensitivities from N. Alawieh, shown in Figure 4. Conclusions From the experiments conducted, it was determined that the thumb and index finger are the most sensitive regions of the hand. These areas should be focused on for testing of stochastic resonance. The output voltages of the circuit should also be continuously monitored throughout testing, because different points in the audio file seemed to produce different voltages. This could have been due to the random frequency, or quieter points in the audio signal. Testing should be done to correlate the displacement of vibration of the piezo buzzer to the input voltage to the circuit. Although the most sensitive areas of the hand were determined, it is still necessary to relate those areas to the displacement of the vibrator. Displacement testing should be conducted by using a laser vibrometer, which uses light scattering to detect the displacement of vibration for the buzzer. For MRI testing, Professor Seo must be wary of the device s compatibility inside the MRI room, and should conduct testing to determine that the device is indeed MRI compatible. Although the materials used are non-ferrous, it is impossible to be 100% sure that the device is MRI compatible without extensively testing the device (the resources were not available for the team to previously conduct such testing).

References [1] Motawar BR, Hur P, Seo NJ. (2011). Roles of cutaneous sensation and gloves with different coefficients of friction on fall recovery during simulated ladder falls. The 35th Annual Meeting of the American Society of Biomechanics. [2] Wells C, Ward LM, Chua R, Inglis JT. (2005). Touch noise increases vibrotactile sensitivity in old and young. Psychological Science. 16:313-320 [3] 1991 Hand Anthropometry of US Army Personnel. [4] Rosen, C. Hiremath, B. Newnham, R. (1992). Piezoelectricity. New York, NY: Springer. pp. 1-12. [5] Alawieh, N. (2011). Tactor to optimize skin response to vibration.