TWTD Series: Heavy duty switches built to last

Similar documents
Switches & Pilot Devices

Switches & Pilot Devices

Switches & Pilot Devices

Complete units: Push-buttons ø 22mm

Bulletin 800H Hazardous Location Push Buttons Product Overview/Specifications. Table of Contents See below.

Complete units: Selector switches ø 22mm

Complete units: Mushroom heads ø 22mm

Control Stations ø 22

Operator Heads: ø 22mm

800T T2 H2 E E X X. a b c d e f g Right Left Right Left. d, e, f, g. c (cont'd) 1-, 2-, 3-, 4-Way Toggle Switches (Bul. 800T only)

Operator Heads: ø 22mm

Separate units: Blocks

Relays & Sockets RU Series Universal Relays. With Latching or Momentary Lever. Standard (without lever) Key features:

Relays & Sockets RY/RM RY/RM Series Miniature Relays. Part Number Selection

Pendant control stations 6

Control stations and enclosures Pendant control stations, for control circuits Double insulated or metal, types XAC-B and XAC-M

PUSHBUTTON SWITCH / SELECTOR SWITCH / ILLUMINATED PUSHBUTTON SWITCH PSA, LPSA TYPE

Table of Contents. 22mm Push Buttons. 30mm Metal Push Buttons. 22mm Plastic Enclosures, Control Boxes & Installation Instructions 30-35

Switches & Pilot Devices

OMRON MK-I / -S RELAY

Model Number Structure

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

Round Indicator Lights Mounting Hole Page

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

and signalling units Ø 22 1 Harmony XB7 Monolithic pushbuttons, switches and pilot lights

Relays & Sockets. RF2V 2-Pole Force Guided Relays/SJ Series Relay Sockets. UL/Recogntion File No. E55996 TÜV SÜD. EU Low Voltage Directive

General-purpose Relay

M = Maintained S = Spring Return. Operator Only ➊ No Contacts M M 800T-00HX2KB6 M M 800T-24HR2KB6AX 800T-24HR17KB6AX Incandescent

Signaling Lights. SLC40 Series Panel Mounted Annunciators. SLC 40 Series Annunciators

A W - A 2A R - 24D - 1

Two-way Action Test Button (Models with Lockable Test Button) For Momentary Operation

General-purpose Relay

HMI Components. Series. Raised design PCB (with adaptor) Machinery and Automation. Indicator Illuminated pushbutton

RJ Series Slim Power Relays

Relays & Sockets. RF1V Force Guided Relays/SF1V Relay Sockets. Certification Organization/ File Number. UL/c-UL File No.

Section. Display Lights. Selection Guides... C 2. SignaLight Towers... C 4

Position switches FM series

Section. Display Lights Selection Guides... C 2. SignaLight Towers 70mm LT7 Modular Series... C 4 56mm LT1 Series...

FM series position switches

ø30 ARN/ARNS Series Mono-lever Switches Switches

Pendant control stations 6

Characteristics 5 TeSys k contactors and reversing contactors

Relays & Sockets. RH Series Compact Power Relays. Part Number Selection. Blade Terminal

NS..S contactor relays - with spring terminals AC operated

Sorenson Lighted Controls

1.3. Pushbuttons and Indicating Lights.

Pendant control stations 6

MK-S (New Models) General-purpose Relays. New Super MK Relays. Models with Latching Lever Added to the Series. Features. Model Number Structure

Accessories. Accessories

Solid-state Timer H3DS

LR Position Switches TECHNICAL DATASHEET

Specifications. Safety Ratings. Standards. Safety Classification

onlinecomponents.com

Local control stations for Zone 1 and Zone 21. Features. Description

60 Series - General purpose relays 6-10 A. Features Plug-in mount 10 A General purpose relay

RU Series Universal Relays

Safety switches with slotted hole lever

Pushbutton Units Flush, Extended, Mushroom Head or Jumbo Mushroom Head Operators. Flush Button. Catalog Number

HMI Components. Series. Flush design Raised design PCB (with adaptor) Indicator Pushbutton Illuminated pushbutton

Snap Action Switches Technical Guide

Enclosure rating. LED indicator with test button G2R-1-SNI G2R-2-SNI Unsealed Diode. LED indicator and diode with test button G2R-1-SNDI G2R-2-SNDI

1.7. Pushbuttons and Indicating Lights. Standards and Certifications UL Listed File No. E CSA Certified File No. LR68551

DISCONNECT SWITCHES. UL Listed CSA Certified

Position switches FR series

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

DPDT MY2N-D2 MY2IN-D2 --- (DC only) 4PDT MY4N-D2 MY4IN-D PDT (bifurcated) MY4ZN-D2 MY4ZIN-D2 --- With built-in CR

Display Lights. Display Lights. LT1 Series. LT1 Series SignaLight Light Towers. Display Lights with a Tower of Advantages

MICRO SWITCH Key-Operated Safety Interlock Switch GK Series Issue 1. Datasheet FEATURES DESCRIPTION POTENTIAL APPLICATIONS DIFFERENTIATION

Type CP-S, CP-C & CP-A Switch mode

Details on the New G2RS

LC2D09BL REVERSING CONTACTOR 575VAC 9A IEC

Modular equipment. Presentation, standards. Standard contactors TeSys GC

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

General data. 13/20 Siemens IC Overview Front plate mounting

Parts Catalog. S-Series Slicer Manual Frozen Option S13. Model:

3 - Protection components Circuit-breakers

GT3W Series Dual Time Range Timers. CSA Certified File No.LR58183 LR96764 LR83814

Amphenol. Circular. Connectors C 16-1 / C Circular Connectors. Amphenol-Tuchel Electronics

MINIATURE RELAY FOR WIDER APPLICATIONS

Standard C800 16A Switches & CBN800 Switches from 10 ma

Datasheet - ZQ N

Pluggable interface relays CR-U Universal relays

Zelio Control Measurement Relays

Bulletin 800R 30.5 mm Push Button Stations Hermetically Sealed for Division 2/Zone 2

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

Dispozitive de acţionare şi indicatori

Parts Catalog. S-Series Slicer Smart Manual SG13. Model:

Junction Box Padlock Kit. Field installed kit requires drilling of only 4 holes. Compatible with 1414 Series

EAO Product Information. Series 84

IP series Pushbutton switches for harsh environments - bushing Ø 12 mm - momentary

Timers. GT3A Series Analog Timers. GT3A-1 GT3A-2 GT3A-3 GT3A-4,-5,-6 Operation Multi-mode Multi-mode with inputs (11 pins) Time Range

62 Series - Power relays 16 A. Features / /

LC1D25BL TeSys D contactor - 3P(3 NO) - AC-3 - <= 440 V 25 A - 24 V DC coil

Contents H3CR. DIN 48 x 48-mm Multifunctional Timer Series. Broad Line-up of H3CR Series H3CR-A. Solid-state Timer. Common to ALL Timers

ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 SPDT SPDT H3CA-8H H3CA-8H

Model Number Structure

Solid-State Digital Counter H7AN

RE7CP13BU adjustable symmetrical flashing relay s - 24 V AC DC - 2OC

Overtravel of 3.5 mm max. Power source DC D5C-1DS0 D5C-1DP0 D5C-1DA0 AC D5C-1AS0 D5C-1AP0 D5C-1AA0 Antenna only D5C-00S0 D5C-00P0 D5C-00A0

Standard Product. Free-Stand Cabinets 19-in. Mini-Rack Cabinet, Components and Accessories

Transcription:

ø0mm - TWTD Series iltight TWTD Series Full Size NEMA Pushbuttons TWTD Series: Heavy duty switches built to last features include: Variety of button sizes up to 9/6" (65mm) Rugged construction includes chrome plated zinc locking ring die cast zinc mounting threads, screw mounted contact blocks LED or incandescent illumination Transformer or full voltage Transparent contact windows Slow make, double break self cleaning contacts Modular construction for maximum flexibility Double nickel plated terminal screws Available assembled or as sub-components NEMA x and IP65 watertight/oiltight panel Large M.5 screw terminals with captive sems plate The rugged series of TWTD switches offers both variety and durability in an attractive design. With button sizes up to 9/6" (65mm), chrome plated zinc locking rings, die cast zinc mounting threads, steel anti-rotation rings, and self cleaning contacts, the TWTD's are here to stay. The TWTD series also offers either LED or incandescent illumination in full voltage and transformer models. Transparent contact windows allow the viewing of IDEC's self cleaning slow-make/slow-break contacts. Regardless of your switching needs, the TWTD series provides the kind of long lasting, industrial strength quality you've come to expect from IDEC. UL Listed File No. E7066 File No. LR866 Ref. No. 767MC Certificate No. 00500055658-66 www.idec.com USA: (800) 6-IDEC or (08) 77-0550, Canada: (888) 7-IDEC

iltight ø0mm - TWTD Series Specifications Mechanical-Electrical Specifications Conforming to Standards Approvals UL Listed File No. E7066 Ref. No. 767MC perating Temperature Vibration Resistance Shock Resistance Electric Shock Protection Degree of Protection Mechanical Life Pollution Degree (conforming to IEC6097-) Rated perational Characteristics Rated Insulation Voltage Rated Switching ver-voltage Rated Impulse Withstanding Voltage Rated Thermal Current Minimum Switching Capacity Contact peration perating Force Terminal Referencing Recommended Terminal Torque External Short-Circuit Protection Applicable Wire Size Contact Resistance Contact Gap Lamp Ratings Maximum Inrush Current Contact Material File No. LR866 EN6097-, EN6097-5-, VDE0660-00, UL508, CSA C- No. CSA: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (00/0, 5, 0, 00/0, 0, 0, 80, 00/0, 80V) UL: pushbuttons and selector switches: A600 pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (00/0, 5, 0, 00/0, 0, 0, 80, 00/0, 80V) TÜV: pushbuttons and selector switches: A600=P600 (N, NC)/Q600 (N-EM, NC-LB) pilot lights and illuminated pushbuttons, direct supply pilot lights and illuminated pushbuttons with integral transformer (00/0, 5, 0, 00/0, 0, 0, 80, 00/0, 80V) peration: 5 to +50 C (without freezing) Storage: 0 to +70 C (without freezing) 0 to 55Hz, 98m/sec (0g) conforming to IEC6068--6 980m/sec (00g) conforming to IEC6068--7 Class 0 conforming to IEC6056 IP65 (from front of the panel) (conforming to IEC6059) IP5 (key switches) NEMA,,, R, S,,, 5,, (conforming to NEMA ICS6-0) Momentary pushbuttons: 5,000,000 (900 operations per hour) All other switches: 500,000 for switches not using a transformer for switches using a transformer AC-5: A600 or Ue = 50V, le = A (N, NC, N-EM, NC-LB) DC-: P600 or Ue = 5V, le =.A (N, NC) DC-: Q600 or Ue = 5V, le = 0.9A (N-EM, NC-LB) 600V Less than kv, conforming to IEC6097- kv for contact circuit.5kv for lamp circuit 0 Amp 5 ma at V AC/DC Slow break NC or N, self-cleaning Flush and extended pushbuttons with N or NC contact: 6.±N (momentary), 7.0±N (maintained) Additional contacts N or NC: +.N (momentary), +.N (maintained) Conforming to CENELEC EN50005 0.8 N m (7. in lb.) 0A 50V fuse conforming to IEC6069- Minimum x AWG, max. x AWG or x AWG Initial contact resistance of 50mΩ or less mm (N and NC) mm (N-EM and NC-LB) Incandescent: W LEDs: 6,, V: 0mA / 0, 0V: 0mA 0 A (0 msec) Silver Contact Ratings Contact Ratings by Utilization Category IEC 6097-5- AC-5 (A600) DC- (P600) Contact Ratings by Utilization Category perational Voltage V 8V 50V 0V 0V 0V peration Current AC 50/60 Hz DC AC- Control of resistive loads & solid state loads 0A 0A 0A 6A A AC-5 Control of electromagnetic loads (> 7VA) 0A 7A 5A A A DC- Control of resistive loads & solid state loads 8A 5A.A.A DC- Control of electromagnets 5A A.A 0.6A www.idec.com USA: (800) 6-IDEC or (08) 77-0550, Canada: (888) 7-IDEC -67

ø0mm - TWTD Series iltight Non-Illuminated Pushbuttons (Assembled) Function B: Momentary : Maintained V: Pushlock Turn Reset Y: Push-Pull Bezel Shape Blank: ctagonal F: Full Shroud G: Mushroom Shroud P: Neoprene Boot Series Designation D: TWTD Series Assembled Pushbuttons A B ( ) D 0 N - B Button Color B: Black G: Green R: Red S: Blue W: White Y: Yellow Contact Arrangement 0: N 0: NC 0: N 0: : N-NC : N- Button Shape : Flush : Extended : Mushroom Ø 0mm : Jumbo Mushroom Ø 65mm. Use only when interpreting part numbers. Do not use for developing part numbers.. Custom contact configurations available, contact IDEC for details. -68 www.idec.com USA: (800) 6-IDEC or (08) 77-0550, Canada: (888) 7-IDEC

iltight ø0mm - TWTD Series Non-Illuminated Pushbuttons (Assembled) con t s: Non-Illuminated Pushbuttons Flush Extended Extended with Neoprene Boot Recessed Extended with Full Shroud Ø 0mm Mushroom Head Contacts N NC N-NC N N NC N-NC N N NC N-NC N N NC N-NC N N NC N-NC N N NC N-NC N Momentary ABD0N-➀ ABD0N-➀ ABDN-➀ ABD0N-➀ ABD0N-➀ ABD0N-➀ ABD0N-➀ ABDN-➀ ABD0N-➀ ABD0N-➀ ABPD0N-➀ ABPD0N-➀ ABPDN-➀ ABPD0N-➀ ABPD0N-➀ ABFD0N-➀ ABFD0N-➀ ABFDN-➀ ABFD0N-➀ ABFD0N-➀ ABFD0N-➀ ABFD0N-➀ ABFDN-➀ ABFD0N-➀ ABFD0N-➀ ABD0N-➀ ABD0N-➀ ABDN-➀ ABD0N-➀ ABD0N-➀ Maintained AD0N-➀ AD0N-➀ ADN-➀ AD0N-➀ AD0N-➀ AD0N-➀ AD0N-➀ ADN-➀ AD0N-➀ AD0N-➀ APD0N-➀ APD0N-➀ APDN-➀ APD0N-➀ APD0N-➀ AFD0N-➀ AFD0N-➀ AFDN-➀ AFD0N-➀ AFD0N-➀ AFD0N-➀ AFD0N-➀ AFDN-➀ AFD0N-➀ AFD0N-➀ AD0N-➀ AD0N-➀ ADN-➀ AD0N-➀ AD0N-➀. In place of ➀, specify the Button Color Code.. For sub-assembly part numbers, see next page.. For accessories, see page -88.. Neoprene boot available only in Black (B), Green (G), Red (R) and Yellow (Y). Button Color Code Color Code Black Green Red Blue White Yellow B G R S W Y Ø 0mm Mushroom Head with Full Shroud N NC N-NC N ABGD0N-➀ ABGD0N-➀ ABGDN-➀ ABGD0N-➀ ABGD0N-➀ AGD0N-➀ AGD0N-➀ AGDN-➀ AGD0N-➀ AGD0N-➀. 65mm Jumbo mushroom not available in white.. Neoprene boot is not available in blue or white. Ø 65mm Jumbo Mushroom Head N NC N-NC N ABD0N-➀ ABD0N-➀ ABDN-➀ ABD0N-➀ ABD0N-➀ AD0N-➀ AD0N-➀ ADN-➀ AD0N-➀ AD0N-➀ Ø 65mm Jumbo Mushroom Head with Shallow Shroud N NC N-NC N ABGD0N-➀ ABGD0N-➀ ABGDN-➀ ABGD0N-➀ ABGD0N-➀ AGD0N-➀ AGD0N-➀ AGDN-➀ AGD0N-➀ AGD0N-➀ Ø 65mm Jumbo Mushroom Head With Deep Shroud N NC N-NC N ABFD0N-➀ ABFD0N-➀ ABFDN-➀ ABFD0N-➀ ABFD0N-➀ AFD0N-➀ AFD0N-➀ AFDN-➀ AFD0N-➀ AFD0N-➀ www.idec.com USA: (800) 6-IDEC or (08) 77-0550, Canada: (888) 7-IDEC -69

ø0mm - TWTD Series iltight Non-Illuminated Pushbuttons (Sub-Assembled) Contact Block + perator + Button + = Complete Part s: perators Flush/Extended Extended with Full Shroud Momentary Maintained ABD-00 AD-00 ABFD-00 AFD-00 s: Buttons and Lenses Flush Extended Ø 0mm Mushroom ABDBN- ABDBN- Ø 0mm Mushroom/ Ø 65mm Jumbo Mushroom ABD-00 AD-00 ABDBN- Ø 65mm Jumbo Mushroom Ø 0mm Mushroom with Full Shroud ABDBN- ABGD-00 AGD-00 Ø 65mm Jumbo Mushroom with Shallow Shroud In place of, specify the Button Color Code. (See table previous page) ABGD-00 AGD-00 s: Contact Blocks Description N NC Ø 65mm Jumbo Mushroom with Deep Shroud ABFD-00 AFD-00 BST-00 BST-00S (early make) BST-00 BST-00S (late break) Dummy Block BST-D. Dummy blocks (no contacts) are used with an odd number of contact blocks.. Combining BST-00S and BST-00S result in overlapping contacts. -70 www.idec.com USA: (800) 6-IDEC or (08) 77-0550, Canada: (888) 7-IDEC

iltight ø0mm - TWTD Series E-Stops (Assembled) Function V: Pushlock Turn Reset Y: Push-Pull Illumination Blank: None L: Illuminated Series Designation D: TWTD Series Button/Lens Size : 0mm Mushroom Assembled E-Stops A V (L) D (99) (D) N - R - (V) Lamp Voltage (full voltage illuminated units only) 6V: 6V AC/DC V: V AC/DC V: V AC/DC 0V: 0V AC/DC 0V: 0V AC/DC Button/Lens Color A: Amber R: Red W: White G: Green S: Blue Y: Yellow Illuminated Circuit (illuminated unit only) 99: Full Voltage (lamp determines voltage) 6:0V AC Step Down Transformer 6: 0V AC Step Down Transformer 86: 80V AC Step Down Transformer Lamp Type (illuminated units only) Blank: Incandescent D: LED Contact Arrangement 0: N 0: NC 0: N 0: : N/NC : N/. Use only when interpreting part numbers. Do not use for developing part numbers.. Custom contact configurations available, contact IDEC for details. www.idec.com USA: (800) 6-IDEC or (08) 77-0550, Canada: (888) 7-IDEC -7

ø0mm - TWTD Series iltight E-Stops (Assembled) s: E-Stop Switches Contacts Ø 0mm Pushlock Turn Reset Ø 0mm Illuminated Pushlock Turn Reset Ø 0mm Push-Pull Ø 0mm Push-Pull Ø 0mm Momentary Push-Pull (-position) Non-Illuminated Full Voltage Transformer Non-Illuminated Full Voltage Transformer Full Voltage Transformer N NC N-NC N N-NC N N-NC N N NC N-NC N N-NC N N-NC N N-NC NC-LB N-NC NC-LB AVD0N-R* AVD0N-R* AVDN-R* AVD0N-R* AVD0N-R* AVLD99➄N-R-➂* AVLD990➄N-R-➂* AVLD990➄N-R-➂* AVLD ➃ ➄N-R* AVLD ➃ 0➄N-R* AVLD ➃ 0➄N-R* AYD0N-➀ AYD0N-➀ AYDN-➀ AYD0N-➀ AYD0N-➀ AYLD99➄N-➁-➂ ** AYLD990➄N-➁-➂ ** AYLD990➄N-➁-➂ ** AYLD ➃ ➄N-➁ ** AYLD ➃ 0➄N-➁ ** AYLD ➃ 0➄N-➁** AYLD99➄N-➁-➂ -TK96 AYLD990S➄N-➁-➂-TK96 AYLD ➃ ➄N-➁-TK96 AYLD ➃ 0S➄N-➁-TK96 Position Push-Pull Contact Push Center Pull NC (BST-00) NC-LB (BST-00S) N (BST-00) N-EM (BST-00S) 0 0 0 0 0 0. In place of ➀, specify the button color code. In place of ➁, specify the lens color code.. In place of ➂, specify the Full Voltage (lamp voltage) Code.. In place of ➃, specify the transformer voltage code. 5. In place of ➄, specify the Lamp Type code. 6. *Available in red only. 7. position push-pull available in spring return to center only. 8. The most common configuration for motor starting applications. 9. For accessories, see page -88. 0. For dimensions, see page -9. Button Color Code Color Code Black Green Red Blue Yellow B G R S Y ➁ LED Color Codes Color Code Amber Green Red Blue White A G R S W s: Unibody E-Stops Contacts Ø 0mm Pushlock Turn Reset (available in Red only) Illuminated Ø 0mm Pushlock Turn Reset (available in Red only) N-NC N-NC HNE-BVF-R* HNE-BVF0-R* HNE-LVFQ➄-R-➂ HNE-LVF0Q➄-R-➂. * Available in Red only.. **Not available in blue.. In place of ➂, specify Full Voltage Code.. With single unit construction, the positive action contacts are integrated in the body of the switch. This provides an extra degree of safety and reliability for critical emergency stop functions. 5. For nameplates and accessories, see page A-96. 6. For dimensions, see page A-00. 7. For sub-assembly part numbers, see next page. 8. HNE series E-stops comply with EN8, the IEC E-Stop Addendum to the Low Voltage Directive, this includes tamper proof operation whereby a change of contact state is not possible by teasing or floating the operator. ➂ Full Voltage Code Voltage Code 6V AC/DC V AC/DC V AC/DC 0V AC 0V AC 6V V V 0V 0V (LED only) ➄ Lamp Type Code Lamp Code Incandescent LED ➃ Transformer Voltage Codes Voltage Code 0VAC 0VAC 80VAC -7 www.idec.com USA: (800) 6-IDEC or (08) 77-0550, Canada: (888) 7-IDEC Blank D 6 6 86 Transformers step down to 6V.

iltight ø0mm - TWTD Series E-Stops (Sub-Assembled) Transformer* + perator + Lamp + Button/Lens = Complete Part *Not required for full voltage units (full voltage clips used instead). s: perators Ø 0mm Pushlock Turn Reset Illuminated Ø 0mm Pushlock Turn Reset Ø 0mm Push-Pull Illuminated Ø 0mm Push-Pull AVD-00 AVLD-0600N AYD-00 pos AYLD-0600 pos AYLDTK96-0B0 s: Lamps Type Voltage LED 6V AC/DC LSTD-6➁ V AC/DC LSTD-➁ V AC/DC LSTD-➁ 0V AC LSTD-H➁ 0V AC LSTD-M➁ Incandescent 6V AC/DC IS-6 V AC/DC IS- V AC/DC IS- 0VAC L-0L. In place of ➁, specify the LED color code.. The LED contains a current-limiting resistor and a protection diode. s: Contact Blocks Description All Control Units N NC Button Color Code Color Code Black Green Red Blue Yellow B G R S ➁ LED Color Codes Color Code Amber Green Red Blue White Y A G R S W s: Buttons and Lenses Part No. BST-00 BST-00S (early make) BST-00 BST-00S (late break) Button for Pushlock Turn Reset E-Stop (Ø 0mm, red only) Lens for Illuminated Pushlock Turn Reset E-Stop (Ø 0mm, red only) Button for Push-Pull E-Stop (Ø 0mm) Lens for Illuminated Push-Pull E-Stop (Ø 0mm) AVNB-R AVLNLU-R AYDBN- pos* AYLDL-➁ pos AYLDL-➁ Dummy Blocks BST-D. Dummy blocks (no contacts) are used with an odd number of contact blocks.. Combining BST-00S and BST-00S result in overlapping contacts (remain on, or closed, when switch is moved between two positions). s: Full Voltage Clips Primary Voltage (50/60Hz) Full Voltage Clips ( req d for each unit) s: Transformers Primary Voltage Description (50/60Hz) 0V AC 0V AC APD-F Part Number TWD-06 TWD-06. In place of, specify the Button Color Code. (See table below). In place of ➁, specify the LED Color Code.. *Not available in blue. 80V AC 6V secondary voltage (uses 6V lamp). TWD-086 www.idec.com USA: (800) 6-IDEC or (08) 77-0550, Canada: (888) 7-IDEC -7

ø0mm - TWTD Series iltight Pilot Lights (Assembled) Function P: Pilot Light Series Designation D: TWTD Series Lens Shape : Dome Rated perational Voltage (Primary) Transformer Type Full Voltage Type 6:0V AC 99:Full Voltage 6:0V AC 86:80V AC Assembled Pilot Lights A P D 6 D N - R - ( ) Lamp Voltage (Full Voltage nly) 6V: 6V AC/DC V:V AC/DC V:V AC/DC 0V:0V AC 0V: 0V AC (LED only) Lens Color Code A: Amber G: Green R: Red S: Blue W: White Y: Yellow Lamp Type Blank: Incandescent Lamp D: LED Lamp Use only when interpreting part numbers. Do not use for developing part numbers. s: LED and Incandescent Pilot Lights perating Voltage Transformer Dome LED Incandescent Full Voltage Dome 0V AC 0V AC 80V AC APD6DN-➁ APD6DN-➁ APD86DN-➁ APD6N-➁ APD6N-➁ APD86N-➁ APD99DN-➁-➂ APD99N-➁-➂ ➁ Lens Color Code Color Code Amber Green Red Blue White Yellow A G R S W Y. In place of ➁, specify the Lens/LED Color Code.. In place of ➂, specify the Full Voltage Code (lamp voltage). ➂ Full Voltage Code Voltage Code 6V AC/DC 6V V AC/DC V V AC/DC V 0V AC 0V 0V AC (LED only) 0V -7 www.idec.com USA: (800) 6-IDEC or (08) 77-0550, Canada: (888) 7-IDEC

iltight ø0mm - TWTD Series Pilot Lights (Sub-Assembled) Transformer* + perator + Lamp + Lens = Complete Part Note: Not required for full voltage units (full voltage clips used instead). s: perators Full Voltage AC Adaptor/Transformer APD-99 APD-006 s: Full Voltage Clips Primary Voltage (50/60Hz) APD-F Required for all full voltage models. Two pieces each. s: Transformers Primary Voltage Description (50/60Hz) Part Number The lens, lamp, and transformer/adaptor or the full voltage clips must be ordered separately. Transformers 0V AC TWD-06 0V AC TWD-06 s: Lenses 80V AC TWD-086 Dome Lens 6V secondary voltage (use 6V lamp). APN06L-➁. In place of ➁, specify the Lens Color Code.. LED and incandescent lenses differ in shade only. Some colors have only one shade. ➁ Lens/LED Color Code Color Code Amber A Green G s: Lamps Type Voltage 6V AC/DC LSTD-6➁ LED V AC/DC LSTD-➁ Red Blue White Yellow R S W Y V AC/DC LSTD-➁ 0V AC LSTD-H➁ 0V AC LSTD-M➁ Incandescent 6.V AC/DC IS-6 V AC/DC IS- V AC/DC IS- 0VAC, -8W L-0L. In place of ➁, specify the LED color code.. The LED contains a current-limiting resistor and a protection diode. www.idec.com USA: (800) 6-IDEC or (08) 77-0550, Canada: (888) 7-IDEC -75

ø0mm - TWTD Series iltight Illuminated Pushbuttons (Assembled) Function L: Momentary Action L: Alternate Action Bezel Shape Blank: ctagonal F: Full Shroud Series Designation D: TWTD Series Lens Shape : Extended : Mushroom Ø 0mm Rated perational Voltage (Primary) Transformer Full Voltage Type 6:0V AC 99:Full Voltage 6:0V AC 86:80V AC Assembled Illuminated Pushbuttons A L ( ) D 6 (D) N - R - ( ) Lamp Voltage (Full Voltage nly) 6V: 6V AC/DC V: V AC/DC V: V AC/DC 0V:0V AC 0V: 0V AC (LED only) Lens Color Code A: Amber G: Green R: Red S: Blue W: White Y: Yellow Lamp Type Blank: Incandescent Lamp D: LED Contact Arrangement 0: N 0: : N-NC. Use only when interpreting part numbers. Do not use for developing part numbers.. All transformers and AC Adaptors step down to 6V. -76 www.idec.com USA: (800) 6-IDEC or (08) 77-0550, Canada: (888) 7-IDEC

iltight ø0mm - TWTD Series Illuminated Pushbuttons (Assembled) con t Part numbers: Illuminated Pushbuttons Extended Lens Extended Lens with Full Shroud Ø 0mm Mushroom Lens Full Voltage Transformer Full Voltage Transformer Full Voltage Transformer Contacts N-NC N N-NC N N-NC N N-NC N N-NC N N-NC N Momentary ALD99➄N-➁-➂ ALD990➄N-➁-➂ ALD990➄N-➁-➂ ALD ➃ ➄N-➁ ALD ➃ 0➄N-➁ ALD ➃ 0➄N-➁ ALFD99➄N-➁-➂ ALFD990➄N-➁-➂ ALFD990➄N-➁-➂ ALFD ➃ ➄N-➁ ALFD ➃ 0➄N-➁ ALFD ➃ 0➄N-➁ ALD99➄N-➁-➂ ALD990➄N-➁-➂ ALD990➄N-➁-➂ ALD ➃ ➄N-➁ ALD ➃ 0➄N-➁ ALD ➃ 0➄N-➁ Maintained ALD99➄N-➁-➂ ALD990➄N-➁-➂ ALD990➄N-➁-➂ ALD ➃ ➄N-➁ ALD ➃ 0➄N-➁ ALD ➃ 0➄N-➁ ALFD99➄N-➁-➂ ALFD990➄N-➁ ➂ ALFD990➄N-➁-➂ ALFD ➃ ➄N-➁ ALFD ➃ 0➄N-➁ ALFD ➃ 0➄N-➁ ALD99➄N-➁-➂ ALD990➄N-➁-➂ ALD990➄N-➁-➂ ALD ➃ ➄N-➁ ALD ➃ 0➄N-➁ ALD ➃ 0➄N-➁. In place of ➁, specify the Lens Color Code.. In place of ➂, specify the Full Voltage Code (lamp voltage).. In place of ➃, specify the Transformer Voltage Code.. In place of ➄, specify the Lamp Type Code. ➁ Lens Color Codes Color Code Amber A Green G Red R Blue S White W Yellow Y ➄ Lamp Type Code Lamp Code Incandescent Blank LED D ➂ Full Voltage Codes Voltage Code 6V AC/DC 6V V AC/DC V V AC/DC V 0V AC 0V 0V AC (LED only) 0 V ➃ Transformer Voltage Codes Voltage Code 0VAC 0VAC 80VAC 6 6 86 6V secondary voltage (uses 6V lamp). www.idec.com USA: (800) 6-IDEC or (08) 77-0550, Canada: (888) 7-IDEC -77

ø0mm - TWTD Series iltight Illuminated Pushbuttons (Sub-Assembled) Transformer* + Contact Block + perator + Lamp + Lens = Complete Part * Not required for full voltage types (full voltage types use APD-F full voltage clips). s: perators s: Lamps Type Voltage Momentary Maintained 6V AC/DC LSTD-6➁ LED Extended V AC/DC LSTD-➁ V AC/DC LSTD-➁ ALD-0600 ALD-0600 0V AC LSTD-H➁ 0V AC LSTD-M➁ Incandescent 6V AC/DC IS-6 Extended with Full Shroud V AC/DC IS- ALFD-0600 ALFD-0600 V AC/DC IS- 0VAC L-0L ➁ Lens/LED Color Codes Color Code Amber Green Red Blue White Yellow A G R S W Y Mushroom lens not available in yellow. 0mm Mushroom ALD-0600 ALD-0600. In place of ➁, specify the LED Color code.. The LED contains a current-limiting resistor and a protection diode. s: Lenses Part No. Extended Ø 0mm Mushroom ALN06LU-➁ ALNLU-➁. In place of ➁, specify the Lens Color Code.. LED and incandescent lenses differ in shade only. Some colors have only one shade. s: Full Voltage Clips Primary Voltage (50/60Hz) Full Voltage Clips ( req d for each unit) s: Contact Blocks Description All Control Units N NC Dummy Blocks BST-00 BST-00S (early make) BST-D s: Transformers Description Primary Voltage (50/60Hz) Transformers 0V AC BST-00 BST-00S (late break). Dummy blocks (no contacts) are used with an odd number of contact blocks.. Combining BST-00S and BST-00S result in overlapping contacts (remain on, or closed, when switch is moved between two positions). Part Number TWD-06 APD-F 0V AC TWD-06 Required for all full voltage models. 80V AC TWD-086 6V secondary voltage (uses 6V lamp). -78 www.idec.com USA: (800) 6-IDEC or (08) 77-0550, Canada: (888) 7-IDEC

iltight ø0mm - TWTD Series Non-Illuminated Selector Switches (Assembled) Selector (Non-illuminated) Function S: Selector Switch Series Designation D: TWTD Series Number of Positions : -Position : -Position Spring Return Action Blank: Maintained : Spring return from Right : Spring return from Left : -Way spring return from Left and Right Selector (Non-illuminated) Assembled Selector Switches A S D ( ) ( ) N - ( ) Selector (Non-illuminated) Circuit Number (See Circuit # column of Selector Switch Contact Arrangement Chart on beginning on -85.) Contact Arrangement Code 0: N 0: NC 0: N 0: 0: N 0: NC : N-NC : N- perator Code Blank: perator L: perator K: perator Use only when interpreting part numbers. Do not use for developing part numbers. www.idec.com USA: (800) 6-IDEC or (08) 77-0550, Canada: (888) 7-IDEC -79

ø0mm - TWTD Series iltight Part numbers: Non-Illuminated Position Selector Switches perator Position Maintained Spring Return from Right Spring Return from Left Contact Mounting Non-Illuminated Selector Switches (Assembled) con t L R L R L R L R N NC N NC N N N ASD0N ASDL0N ASDK0N ASD0N-6 ASDL0N-6 ASDK0N-6 ASDN ASDLN ASDKN ASD0N ASDL0N ASDK0N ASD0N-0 ASDL0N-0 ASDK0N-0 ASDN ASDLN ASDKN ASDN- ASDLN- ASDKN- ASD0N ASDL0N ASDK0N ASD0N-6 ASDL0N-6 ASDK0N-6 ASDN ASDLN ASDKN ASD0N ASDL0N ASDK0N ASD0N-0 ASDL0N-0 ASDK0N-0 ASDN ASDLN ASDKN ASDN- ASDLN- ASDKN- ASD0N ASDL0N ASDK0N ASD0N-6 ASDL0N-6 ASDK0N-6 ASDN ASDLN ASDKN ASD0N ASDL0N ASDK0N ASD0N-0 ASDL0N-0 ASDK0N-0 ASDN ASDLN ASDKN ASDN- ASDLN- ASDKN- s: Non-Illuminated Position Selector Switches perator Position Maintained Spring Return from Right Spring Return From Left Spring Return Two-Way C C C C L C R L R L R L R L R Contact N N N N N NC Mounting ASD0N ASDL0N ASDK0N ASD0N ASDL0N ASDK0N ASDN ASDLN ASDKN ASDN-09 ASDLN-09 ASDKN-09 ASDN-0 ASDLN-0 ASDKN-0 ASD0N ASDL0N ASDK0N ASD0N ASDL0N ASDK0N ASD0N ASDL0N ASDK0N ASD0N ASDL0N ASDK0N ASDN ASDLN ASDKN ASDN-09 ASDLN-09 ASDKN-09 ASDN-0 ASDLN-0 ASDKN-0 ASD0N ASDL0N ASDK0N ASD0N ASDL0N ASDK0N ASD0N ASDL0N ASDK0N ASD0N ASDL0N ASDK0N ASDN ASDLN ASDKN ASDN-09 ASDLN-09 ASDKN-09 ASDN-0 ASDLN-0 ASDKN-0 ASD0N ASDL0N ASDK0N ASD0N ASDL0N ASDK0N. The truth table indicates the operating position of contact block when the operator is switched to that position. = n (closed contacts) = ff (open contacts) = verlapping Contacts: Remain on (closed contacts) when switch is moved between these two positions.. All knob and lever selector switches come in black. ther colors are available by ordering the knob or lever separately.. Custom contact arrangements available, see page -85 or call IDEC for details. ASD0N ASDL0N ASDK0N ASD0N ASDL0N ASDK0N ASDN ASDLN ASDKN ASDN-09 ASDLN-09 ASDKN-09 ASDN-0 ASDLN-0 ASDKN-0 ASD0N ASDL0N ASDK0N ASD0N ASDL0N ASDK0N -80 www.idec.com USA: (800) 6-IDEC or (08) 77-0550, Canada: (888) 7-IDEC

iltight ø0mm - TWTD Series Non-Illuminated Selector Switches (Sub-Assembled) Contact Blocks + perator + or * + Color Insert* = Complete Part. * Not needed with key type switches.. type shown. s: perators Appearance/ Position Description & Maintained ASD00 Spring-Ret. from Right Spring-Ret. from Left Maintained, Cam Maintained, Cam Spring-Ret. from Right, Cam Spring-Ret. from Right, Cam Spring-Ret. from Left, Cam Spring-Ret. from Left, Cam Spring-Ret. from L/R, Cam Spring-Ret. from L/R, Cam Part Number ASD00 ASD00 ASD00- ASD00- ASD00- ASD00- ASD00- ASD00- ASD00- ASD00- Maintained ASDK00-RA Spring-Ret. from Right Spring-Ret. from Left Maintained, Cam Maintained, Cam Spring-Ret. from Right, Cam Spring-Ret. from Right, Cam Spring-Ret. from Left, Cam Spring-Ret. from Left, Cam Spring-Ret. from L/R, Cam Spring-Ret. from L/R, Cam ASDK00-RL ASDK00 ASDK00--RA ASDK00--RA ASDK00--RLC ASDK00--RLC ASDK00--RRC ASDK00--RRC ASDK00--RC ASDK00--RC. rder knobs, levers, color inserts separately (see below).. For key switches, keys are removable in all maintained positions. ther options available, contact IDEC for details.. See page -87 perator Truth Tables for details of difference between cams. Color Codes / Color Code Black B Blue S Green G Red R Yellow Y White W. / not available in white.. Color inserts not available in Black. s: Handles and Inserts Color Insert In place of, specify the Color Code. s: Contact Blocks Dummy Blocks ASDHHY - ASDHHL - TW-HC - N NC BST-00 BST-00S (early make) BST-D BST-00 BST-00S (late break). Dummy blocks (no contacts) are used with an odd number of contact blocks.. Combining BST-00S and BST-00S result in overlapping contacts (remain on, or closed, when switch is moved between two positions). www.idec.com USA: (800) 6-IDEC or (08) 77-0550, Canada: (888) 7-IDEC -8

ø0mm - TWTD Series iltight Illuminated Selector Switches (Assembled) Assembled Illuminated Selector Switches A SL D () 6 D N - - R - Function SL: Illuminated Selector Switch Series Designation D: TWTD Series Number of Positions : -Position : -Position Spring Return Action Blank: Maintained : Spring return from Right : Spring return from Left : -Way spring return from Left and Right Rated perational Voltage (Primary) Transformer Full Voltage Type 6:0V AC 99: Full Voltage 6:0V AC 86:80V AC Contact Arrangement 0: N 0: 0: N 0: NC : N-NC : N- Lamp Voltage (Full Voltage nly) 6V: 6V AC/DC V:V AC/DC V:V AC/DC 0V:0V AC 0V: 0V AC (LED only) Lens Color Code A: Amber G: Green R: Red S: Blue W: White Y: Yellow Circuit Code Number See Circuit # column of Selector Switch Contact Arrangement Charts on page -85. Lamp Type Blank: Incandescent D: LED Use only when interpreting part numbers. Do not use for developing part numbers. -8 www.idec.com USA: (800) 6-IDEC or (08) 77-0550, Canada: (888) 7-IDEC

iltight ø0mm - TWTD Series Illuminated Selector Switches (Assembled) con t s: Illuminated Position Selector Switches perator Spring Return Spring Return Position Maintained From Right From Left L R L R L R L R Contact N NC Mounting N N N transformer full voltage transformer full voltage transformer full voltage transformer full voltage transformer full voltage ASLD ➃➄N-➁ ASLD99➄N-➁-➂ ASLD ➃0➄N-➁ ASLD990➄N-➁-➂ ASLD ➃0➄N-0-➁ ASLD990➄N-0-➁-➂ ASLD ➃➄N-➁ ASLD99➄N-➁- ➂ ASLD ➃➄N--➁ ASLD99➄N--➁-➂ ASLD ➃➄N-➁ ASLD99➄N-➁-➂ ASLD ➃0➄N-➁ ASLD990➄N-➁-➂ ASLD ➃0➄N-0-➁ ASLD990➄N-0-➁-➂ ASLD ➃➄N-➁ ASLD99➄N-➁-➂ ASLD ➃➄N--➁ ASLD99➄N--➁-➂ ASLD ➃➄N-➁ ASLD99➄N-➁-➂ ASLD ➃0➄N-➁ ASLD990➄N-➁-➂ ASLD ➃0➄N-0-➁ ASLD990➄N-0-➁-➂ ASLD ➃➄N-➁ ASLD99➄N-➁-➂ ASLD ➃➄N--➁ ASLD99➄N--➁-➂ ➄ Lamp Type Code Lamp Code Incandescent LED Blank D ➁ Lens/LED Color Codes Color Code Amber A Green G Red R Blue S White W Yellow Y ➂ Full Voltage Codes Voltage Code 6V AC/DC 6V V AC/DC V V AC/DC V 0V AC 0V 0V AC (LED only) 0V ➃Transformer Voltage Codes Voltage Code 0VAC 0VAC 80VAC 6 6 86 6V secondary voltage (uses 6V lamps). s: Illuminated Position Selector Switches perator Maintained Position C L R L C R Contact Mounting Spring Return From Right Spring Return From Left Spring Return Two-Way C C C L R L R L R N N N N N NC transformer full voltage transformer full voltage transformer full voltage transformer full voltage transformer full voltage transformer full voltage transformer full voltage ASLD ➃ 0➄N-➁ ASLD990➄N-➁-➂ ASLD ➃ 0➄N-➁ ASLD990➄N-➁-➂ ASLD ➃ ➄N-➁ ASLD99➄N-➁-➂ ASLD ➃ ➄N-09-➁ ASLD99➄N-09-➁-➂ ASLD ➃ ➄N-0-➁ ASLD99➄N-0-➁-➂ ASLD ➃ 0➄N-➁ ASLD990➄N-➁-➂ ASLD ➃ 0➄N-➁ ASLD990➄N-➁-➂ ASLD ➃ 0➄N-➁ ASLD990➄N-➁- ➂ ASLD ➃ 0➄N-➁ ASLD990➄N-➁-➂ ASLD ➃ ➄N-➁ ASLD99➄N-➁-➂ ASLD ➃ ➄N-09-➁ ASLD99➄N-09-➁-➂ ASLD ➃ ➄N-0-➁ ASLD99➄N-0-➁-➂ ASLD ➃ 0➄N-➁ ASLD990➄N-➁-➂ ASLD ➃ 0➄N-➁ ASLD990➄N-➁-➂ ASLD ➃ 0D➄N-➁ ASLD990D➄N-➁-➂ ASLD ➃ 0D➄N-➁ ASLD990D➄N-➁-➂ ASLD ➃ D➄N-➁ ASLD99D➄N-➁-➂ ASLD ➃ D➄N-09-➁ ASLD99D➄N-09-➁-➂ ASLD ➃ D➄N-0-➁ ASLD99D➄N-0-➁-➂ ASLD ➃ 0➄N-➁ ASLD990➄N-➁-➂ ASLD ➃ 0➄N-➁ ASLD990➄N-➁-➂ ASLD ➃ 0D➄N-➁ ASLD990D➄N-➁-➂ ASLD ➃ 0D➄N-➁ ASLD990D➄N-➁-➂ ASLD ➃ D➄N-➁ ASLD99D➄N-➁-➂ ASLD ➃ D➄N-09-➁ ASLD99D➄N-09-➁-➂ ASLD ➃ D➄N-0-➁ ASLD99D➄N-0-➁-➂ ASLD ➃ 0➄N-➁ ASLD990➄N-➁-➂ ASLD ➃ 0➄N-➁ ASLD990➄N-➁-➂. In place of ➁, specify the Lens/LED Color Code, in place of ➂, specify the Full Voltage (lamp voltage) Code, in place of ➃, specify the Transformer Voltage Code and in place of ➄ specify the Lamp Type Code.. The truth table indicates the operating position of contact block when the operator is switched to that position. = n (Closed Contacts) = ff (pen Contacts) = verlapping Contacts: Remain on (closed contacts) when switch is moved between these positions www.idec.com USA: (800) 6-IDEC or (08) 77-0550, Canada: (888) 7-IDEC -8

ø0mm - TWTD Series iltight Illuminated Selector Switches (Sub-Assembled) Transformer* + Contact Block + perator + Lamp Lense = Complete Part *Not required for full voltage units (use APD-F full voltage clips instead). s: perators Appearance/ Part Description Positions Number Maintained ASLD00 perator Maintained, Cam ASLD00- Maintained, Cam ASLD00- Spring-Ret. from Right ASLD00 Spring-Ret. from Left ASLD00 Spring-Ret. from Right, Cam ASLD00- Spring-Ret. from Right, Cam ASLD00- Spring-Ret. from Left, Cam Spring-Ret. from Left, Cam ASLD00- ASLD00- Spring-Ret. from L/R, Cam ASLD00- Spring-Ret. from L/R, Cam ASLD00- s: Lenses ASLNHU - ➀ s: Lamps Type Voltage LED 6V AC/DC LSTD-6➁ V AC/DC LSTD-➁ V AC/DC LSTD-➁ 0V AC LSTD-H➁ 0V AC LSTD-M➁ Incandescent 6.V AC/DC IS-6 V AC/DC IS- V AC/DC IS- 0VAC L-0L. In place of ➁, specify the LED color code.. The LED contains a current-limiting resistor and a protection diode. Contact Blocks Description Dummy Blocks BST-00 s: Full Voltage Clips Primary Voltage (50/60Hz) Full Voltage Clips ( req d for each unit) N NC BST-00S (early make) BST-D s: Transformers Primary Voltage Description (50/60Hz) BST-00 BST-00S (late break). Dummy blocks (no contacts) are used with an odd number of contact blocks.. Combining BST-00S and BST-00S result in overlapping contacts (make before break). APD-F Part Number Transformers 0V AC TWD-06 6V secondary voltage 0V AC 80V AC TWD-06 TWD-086 ➁ Lens/LED Color Codes Color Code Amber A Green G Red R Blue S White W Yellow Y -8 www.idec.com USA: (800) 6-IDEC or (08) 77-0550, Canada: (888) 7-IDEC

iltight ø0mm - TWTD Series Contact Arrangement Charts How to Read Contact Arrangement Charts To determine contact block mounting position, first make sure the selector switch is oriented as shown on the right Contact Arrangement Type and quantity of switch contacts L R Circuit Number * N/D = No designation Contact Block Mounting Position or mounting contact blocks on operator Contact Arrangement Chart: -position Selector Switches Mounting perator Contact Block Circuit Description Contact Position Position Number L R perator Position Truth table indicates the operating position of contact block when operator is switched to that position. = n (Closed Contacts) = ff (pen Contacts) = verlapping Contacts: Remain on (closed) when switch is moved between these two positions perator Spring Ret. Spring Ret. Maintained from Rt. from Lt. L R L R L R Contact Block Part number to use when ordering subassembly contact blocks, as required for use with corresponding mounting position N N/D NC 6 N NC N-EM NC-LB N N/D 0 600 60 N/D 0 N N N/D 0 N/D BST-00 / BST-D BST-00 / BST-D BST-00 / BST-00 BST-00 / BST-00 BST-00S / BST-00S BST-00S / BST-00S BST-00 / BST-00 BST-00 / BST-00 BST-00 BST-00 / BST-00 BST-00 BST-00 BST-00 BST-00 BST-00 BST-00 BST-00 BST-00 BST-00 BST-00 BST-00 BST-00 BST-00 / / / ASD00 ASDK00 ASLD00 ASD00 ASDK00 ASLD00 ASD00 ASDK00 ASLD00 ASD00 ASDK00 ASLD00 ASD00 ASDK00 ASLD00 ASD00 ASDK00 ASLD00 ASD00 ASDK00 ASLD00 ASD00 ASDK00 ASLD00 ASD00 ASDK00 ASLD00 ASD00 ASDK00 ASLD00 ASD00 ASDK00 ASLD00 ASD00 ASDK00 ASLD00 ASD00 ASDK00 ASLD00 ASD00 ASDK00 ASLD00 ASD00 ASDK00 ASLD00 ASD00 ASDK00 ASLD00 ASD00 ASDK00 ASLD00 ASD00 ASDK00 ASLD00 ASD00 ASDK00 ASLD00 ASD00 ASDK00 ASLD00 ASD00 ASDK00 ASLD00 ASD00 ASDK00 ASLD00 ASD00 ASDK00 ASLD00 ASD00 ASDK00 ASLD00 ASD00 ASDK00 ASLD00 ASD00 ASDK00 ASLD00 ASD00 ASDK00 ASLD00 ASD00 ASDK00 ASLD00 ASD00 ASDK00 ASLD00 ASD00 ASDK00 ASLD00 ASD00 ASDK00 ASLD00 ASD00 ASDK00 ASLD00 ASD00 ASDK00 ASLD00 ASD00 ASDK00 ASLD00 ASD00 ASDK00 ASLD00 ASD00 ASDK00 ASLD00 www.idec.com USA: (800) 6-IDEC or (08) 77-0550, Canada: (888) 7-IDEC -85

ø0mm - TWTD Series Contact Arrangement Chart: -Position Selector Switches Mounting perator Contact Block Circuit Contact Position Position Number L C R N NC N N N NC 0 0 0 0 N/D 0 0 N/D N/D 0 08 09 0 N/D 05 N/D iltight Description 0 0 BST-00 / BST-00 0 BST-00 / 0 BST-00 0 BST-00 / BST-00 0 BST-00 / 0 BST-00 0 0 BST-00 / 0 BST-00 0 BST-00 / 0 BST-00 0 BST-00 / BST-00 0 BST-00 / BST-00 0 0 BST-00 0 0 BST-00 / 0 BST-00 0 BST-00 0 BST-00 0 0 BST-00 0 BST-00 0 0 BST-00 0 BST-00 0 BST-00 0 BST-00 BST-00 0 BST-00 0 BST-00 0 BST-00 0 BST-00 0 BST-00 0 BST-00 0 BST-00 0 0 BST-00 0 0 BST-00 0 0 BST-00 0 0 BST-00 0 0 BST-00 0 BST-00 0 0 BST-00 0 BST-00 0 0 BST-00 0 BST-00 0 BST-00 0 BST-00 BST-00 0 BST-00 0 BST-00 0 BST-00 0 BST-00 / / / / / / / / Maintained ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- perator Spring Ret. Spring Ret. from Rt. from Lt. ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- Two-Way ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00- ASD00- ASDK00- ASLD00-. Each operator sub-assembly is available as a -" and a -" for -position selector switches. The internal cam of a -" is different from that of a -". This results in designated combinations of open and closed contacts in the various operator positions.. N/D = No circuit number designation required in assembled part number.. = n (closed contacts) = ff (open contacts). verlapping contacts remain on (closed) when switch is moved between these two positions. -86 www.idec.com USA: (800) 6-IDEC or (08) 77-0550, Canada: (888) 7-IDEC L C R L C R L C R L C R

iltight ø0mm - TWTD Series perator Truth Tables Use the following tables to build custom selector switches. Position Selector Switches ASD00 Contact BST-00 (N) BST-00 (NC) BST-00S (N-EM) BST-00S (NC-LB) Mounting Position Position Selector Switches Contact BST-00 (N) perator Position Left Right L R L R L 0 R L R Mounting Position perator Position Left Center Right L R ASD00- ASLD00- ASDK00- BST-00 (NC) BST-00S (N-EM) BST-00S (NC-LB) L R L R L R Contact Mounting Position perator Position Left Center Right ASD00- ASLD00- ASDK00- BST-00 (N) BST-00 (NC) BST-00S (N-EM) L R L R L R. For perator Truth Tables, see next page.. For examples of how to assemble selector switches, see A-8. BST-00S (NC-LB) L R Position Push/Pull Switches perator Position Contact Pull Normal Push BST-00 (N) AYLD BST-00 (NC) BST-00S (N-EM) BST-00S (NC-LB) www.idec.com USA: (800) 6-IDEC or (08) 77-0550, Canada: (888) 7-IDEC -87

ø0mm - TWTD Series iltight Accessories TWTD Series Lamp Removal Tool Tool used to install LED s and incandescent lamps. Standard octagonal units (chrome-pl.). R-55 G-8 Metal Bezel Replacement locking ring/bezel Extended, non-illuminated (chrome-pl.). Extended, illuminated (chrome-pl.). Jumbo Mushroom Shallow Shroud Jumbo Mushroom Deep Shroud Plastic Bezel Black plastic locking ring/bezel GPB Boot/Cover Used to cover and protect pushbuttons. In place of ➀, specify neoprene Rubber Boot color: B (black), G (green), R (red), Y (yellow) Flush units (clear plastic -0 to +60 C). G-8 G-8L ABNG ABNF C- ➀ C- Extended units (clear plastic -0 to +60 C). C- Anti-Rotation Ring Plastic washer For nameplates or panels that should not be scratched. Thrust washer/anti-rotation ring for use with notched panel cutout. GL-DT GL-DS Plastic with locking nut attached. BP- Mounting Hole Plug Plugs used to fill unused 0mm panel cutouts. Metal with locking nut attached B- Grey rubber (-5 to +60 C) B- Terminal Tab Adaptor Tab #50 7/6" x /6" (6.5mm x 0.8mm): Single tab TW-FA Full Voltage Adaptor Used on all full voltage illuminated units. Two required per unit. (M.5 screw and saddle) APD-F Lock ut Adaptor Used to provide lockout protection for TWTD pushbuttons and knob selectors. Ø -/6" (0mm) L-KL Replacement s Pair of s (#0) TW-SK -88 www.idec.com USA: (800) 6-IDEC or (08) 77-0550, Canada: (888) 7-IDEC

iltight ø0mm - TWTD Series Accessories con t s: Fingersafe Covers for TWTD Series Appearance Description Used with N-VL APD-PVL N-VL Fingersafe terminal cover, for full voltage pilot lights, adds mm to overall depth APD99... full voltage pilot lights APD-PVL Fingersafe terminal cover, for contact blocks, adds mm to overall depth Non-Illuminated pushbuttons ABD..., and AD... N-VL Fingersafe terminal cover, adds.5mm to overall depth Transformer pilot lights and illuminated units N-VL Fingersafe terminal cover, adds mm to depth Full voltage illuminated pushbuttons N-VL N-VL Dimensions on page -9. www.idec.com USA: (800) 6-IDEC or (08) 77-0550, Canada: (888) 7-IDEC -89

ø0mm - TWTD Series iltight s: Nameplates Nameplates TWTD Series NALD NAKD NAQD HNAV Dimensions Description Nameplate Black NALD-B NAKD-B NAQD-B HNAV-0 (blank) Red NALD-R NAKD-R NAQD-R Nameplate (engraved).85" (7.5mm).56" (0mm) Ø.9" (0.5mm)." (57.5mm).0" (5mm) Ø.9" (0.5mm).95" (50mm) Ø.9" (0.5mm) NALD-➀ NAKD-➀ NAQD-➀ HNAV-7 Emergency Stop. Nameplates are made of 0.0" aluminum. Lettering is white letters engraved on black background.. In place of ➀, insert either the standard legend code from table below or custom engraving delimited by.. HNAV available in yellow only..95" (50mm) 5mm." (60mm) Emergency Ø.9" (0.5mm) Stop * Standard Legend Codes Pushbuttons Pushbuttons/Selector Switches Selector Switches Legend Code Legend Code Legend Code Legend Code Legend Code AUT-MAN-FF 0 AUT 0 PEN 6 AUT-MAN 0 AUT-FF-MAN 0 CLSE 0 UT 7 CLSE-PEN 0 CLSE-FF-PEN 0 DWN 0 RAISE 8 DWN-UP 0 DWN-FF-SLW 0 *EMERG.STP 0 RESET 9 FAST-SLW 0 FAST 05 REVERSE 0 FR-REV 05 REV-FR 6 FAST-FF-SLW 05 FRWARD 06 RUN HAND-AUT 06 RUN-JG 7 FR-FF-REV 06 HAND 07 SLW HIGH-LW 07 RUN-SAFE 8 LEFT-FF-RIGHT 07 HIGH 08 START JG-RUN 08 SAFE-RUN 9 LWER-FF-RAISE 08 IN 09 *STP LEFT-RIGHT 09 SLW-FAST 0 FF-MAN-AUT 09 INCH 0 STP 5 LWER-RAISE 0 START-STP FF-SLW-FAST 0 JG TEST 6 MAN-AUT STP-START FF-- LW UP 7 FF-N UP-DWN PEN-FF-CLSE SLW-FF-FAST LWER I (Int l n) 50 N-FF SUMMER-FF-WINTER FF (Int l ff) 5 PEN-CLSE UP-FF-DWN 5 N 5 EM 5 RAISE-LWER 5 -FF- 6 HAND-FF-AUT 7. *Available in Red as standard legend code 0 and. To order engraved nameplate and codes, add legend code to nameplate part number. Character height based on the number of characters, space and size of nameplate. Standard character size is /6".. Nameplates with standard legends are the same list price as blank nameplates. Special engravings, additional cost. To specify engraving instructions, use the Nameplate order form on next page. -90 www.idec.com USA: (800) 6-IDEC or (08) 77-0550, Canada: (888) 7-IDEC

iltight ø0mm - TWTD Series Nameplates rder Form TWTD Series Copy this order form and use it to specify Letter Height, Custom Engravings, Location of Engraving on Nameplate, and Quantity Desired. To insure engraving accuracy, fax it to your IDEC representative or Distributor. Your Company: IDEC Rep/Distributor Contact: Name: P number (if known): Telephone: IDEC Rep/Distributor Phone: Fax & Email IDEC Rep/Distributor Fax & Email NALD Nameplate Engraving Location Step. Choose Letter Size - 7/6 or /8. Check the box for the letter size you want. Then write your lettering in box below checkboxes. Note: /8 size letters cannot exceed characters. Step. Specify Quantity. Enter the number of nameplates desired in the box on the right. Qty Sample Letter Sizes 7/6 Letters: A B C D /8 Letters: A B C D 7/6 Letter Size /8 Letter Size 6 characters max (for 7/6 size letters) characters max (for /8 size letters) 5 6 7 8 9 0 5 6 NAKD Nameplate Engraving Location Step. /8 Letter Size nly Specify Lettering Write your lettering in box to the right. Maximum 7 characters per line, maximum lines. Step. Specify Quantity. Enter the number of nameplates desired in the box on the right. Qty 5 6 7 8 9 0 5 6 7 Sample Letter Size /8 Letters: A B C D NAQD Nameplate Engraving Location Step. Choose Letter Size - 7/6 or /8. Check the box for the letter size you want. Then write your lettering in box below checkboxes. Note: /8 size letters cannot exceed 6 characters. 7/6 Letter Size /8 Letter Size 0 characters max (for 7/6 size letters) 6 characters max (for /8 size letters) Step. Specify Quantity. Enter the number of nameplates desired in the box on the right. Qty 5 6 7 8 9 0 5 6 7 8 9 0 Sample Letter Sizes 7/6 Letters: A B C D /8 Letters: A B C D www.idec.com USA: (800) 6-IDEC or (08) 77-0550, Canada: (888) 7-IDEC -9

ø0mm - TWTD Series iltight Dimensions TWTD Series Pushbutton M.5 Terminal Screw Panel Thickness 0.8 to 7.5 Pushbuttons Dimension A Dimension B 5.5 5 ( or blocks) 76 ( or blocks) Mushroom Pushbutton w/full Shroud M.5 Terminal Screw 9 ø5 ø5.5 5.5 0 5 ( or blocks) 76 ( or blocks) w/ac Adapter w/transformer A 0 Panel Thickness 0.8 to 7.5 Illuminated Pushbuttons B M.5 Terminal Screw M Terminal Screw ø0 ø0 Panel Thickness 0.8 to 7.5 B ø5 ø0 Flush Extended Extended w/full Shroud Mushroom Mushroom w/full Shroud Jumbo Mushroom Ø.56" (0mm) Mushroom, Pushlock Turn Reset and Push-Pull Ø.56" (0mm) 0.5" (9mm) 0.566" (.5mm) 0.66" (7mm) 0.858" (mm) 0.96" (mm)." (9mm) *0.975" (5mm) **0.975" (5mm) Note: *Dimension when operator is in reset position. **Dimension when operator is in pull position. Full Voltage M.5 Terminal Screw M Terminal Screw Panel Thickness 0.8 to 7.5 ø ø5 Ø 0.975" (5mm) Ø 0.975"(5mm) Ø." (8.5mm) Ø.56" (0mm) Ø.87" (8mm) Ø.5" (65mm) Ø.56" (0mm) Ø.56" (0mm) ø0 97.5 ( blocks) 0.5 ( blocks) 9 A 0 5.5 6 ( blocks) 86 ( blocks) 9 0 Illuminated Pushbuttons Dimension A Dimension B Flush w/full Shroud Extended w/full Shroud Ø.56" (0mm) Mushroom Pushlock Turn Reset, Push-Pull 0.975" (5mm) Ø 0.96" (mm) 0.995" (5.5mm) Ø 0.96" (mm) Full Voltage 0.7" (9mm) Ø 0.96" (mm) 0.76" (9.5mm) Ø 0.96" (mm) *0.975" (5mm) **0.975" (5mm) Ø.56" (0mm) Ø.56" (0mm) Pilot Lights M.5 Terminal Screw M.5 Terminal Screw Panel Thickness: 0.8 to 7.5 mm ø5 ø5 ø0 Note: *Dimension when operator is in reset position. **Dimension when operator is in pull position. A:9.5 9 B:6.5 0 Selector Switches Panel Thickness 0.8 to 7.5 M.5 Terminal Screw 5 90 5 Panel Thickness 0.8 to 7.5 M.5 Terminal Screw 5 90 5 Panel Thickness 0.8 to 7.5 M.5 Terminal Screw 5 90 5 ø5 ø0 ø5 ø0 ø5 ø0 5.5 5 ( or blocks) 76 ( blocks) 0 5.5 5 ( or blocks) 76 ( blocks).5 0 5.5 5 ( or blocks) 76 ( blocks) 9 6.5 8 0 M.5 Terminal Screws M Terminal Screw Panel Thickness 0.8 to 7.5 (including nameplate) 5 90 5 ø5 ø5 ø0 5.5 6 ( blocks) A: 86 ( blocks) 9 B: 97.5 ( blocks), 0.5 ( blocks) 8 0 All measurements in mm. -9 www.idec.com USA: (800) 6-IDEC or (08) 77-0550, Canada: (888) 7-IDEC

iltight ø0mm - TWTD Series Dimensions TWTD Series con t Selector Switches Panel Cut-ut.6" (mm) Accessory Dimensions L-KL Lock-ut Adaptor 0." (8.mm) Cut-out is the only difference between TW and TWTD.76" (.8mm) Ø 0.95"(5mm) >.95" (50mm)*.97" (50mm) Ø.0" (0.5mm).8" (0mm).76" (70mm).66" (.6mm). *Jumbo Mushroom <.6" (66mm). Minimum mounting centers are applicable to switches with one stack of contact blocks. When mounting two stacks of contact blocks, minimum centers should allow for access to wiring.. The Ø 0.95" (Ø 5mm) recess is necessary when either the nameplate or anti-rotation ring is used..6 (9.5mm).5" (8.5mm).66" (9mm) 0." (8mm) C- Pushbutton Clear Boot Ø.7" (Ø.6mm) Flush: 0.70" (8mm) Extended: 0.858" (mm) GL- Anti-Rotation Ring 0.98" (0.mm) Ø.07" (Ø7.mm) Ø0.858" (mm) B- Mounting Hole Rubber Plug 0.7" (.5mm) Ø." (Ø9mm) Ø0.975" (Ø5mm) 0.7" (.5mm) Finger-Safe Cover N-VL N-VL N-VL 0.6" (6mm) 0.87" (mm) 0.55" (mm)." (mm) 0.7" (8mm) N-VL.5" (8.mm) 0." (6.mm) 0.06" (.mm) 0.6" (6.5mm).0" (0.mm) 0.68" (7.mm) N-VL 0.9" (mm).5" (8mm) 0." (6.mm) 0.9" (.7mm) 0." (0.5mm).5" (8.MM).7" (8MM) N-VL 0.6" (5.5MM) 0." (R.MM) 0.9" (MM) APD-PVL." (0.5mm).5" (7mm).5" (9mm).56" (6.mm) APD-PVL.6" (mm).7" (mm) www.idec.com USA: (800) 6-IDEC or (08) 77-0550, Canada: (888) 7-IDEC -9

ø0mm - TWTD Series iltight Instructions TWTD Series Adjustment for Panel Thickness Each unit is shipped with several waterproof gaskets which are 0.06" (.5mm) and 0." (mm) thick. Combine the gaskets for a dimension approximately equal to panel thickness and install between the bezel and the body of the unit. A trim washer must be used with a thrust washer or a nameplate to prevent the control unit from rotating in the mounting hole. When using anti-rotation rings (trim washer with thrust washer or nameplate), install as shown below. Unit Panel Cut-ut Trim Washer Thrust Washer Nameplate Installation of LED Illuminated Units Transformer units are recommended for use in areas subjected to inductive noise. When using full voltage types, install a protection diode as shown below. Use diode with AC power supply to protect against reverse polarity. Use with DC power supply to protect against surges and noise. Diode Terminal LED Terminal Make sure that LED illuminated units are installed with correct polarity, as indicated at the terminals. Application Example For Push-To-Test Pilot Light A typical application of illuminated pushbuttons is a push-to-test pilot light which can be used to check the lamp/led circuit. Transformer/AC-Adapter Circuit Start Stop L M C M NC T N Selector Switches The operator shaft of each unit has a recess to identify in which direction to install the handle. Align the handle with the recess. Press color insert (TW- HC) into the Standard perating Positions. Test Pilot Light L Standard operation positions -Position, 90 -Position, 5 0 Full Voltage Circuit Stop Start L M NC LS C Non-Illuminated -Position perators 0 0 0 M T N L Test Pilot Light Installation of TWTD Series Units TWTD Pilot Lights TWTD Illuminated Pushbuttons, TWTD Selector Switches (Transformer or Full Voltage) Terminal = Positive Terminal = Negative -9 www.idec.com USA: (800) 6-IDEC or (08) 77-0550, Canada: (888) 7-IDEC