SSRLS-3 / SSRLU-3 Installation Instructions

Similar documents
Installation Instructions Model # TEL-100 / 200 Manual Locking or Self Locking

Packing List MODEL TEL-IAL-481 For Inactive Leaf TRIDENT double door

SECURITECH GROUP, INC. MP POLICE LOCK. MODEL 4840B-TTBG_HG-3_ or 4840B-TTBG_HG-4_. Packing List. Documentation: Items: Fasteners:

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

Safety glasses Measuring tape Level Pencil Power drill Center punch Phillips screw driver Saw horse

98/9927. Devices covered by these instructions: Surface Vertical Rod Exit Device

33/35A Series. Devices covered by these instructions: Rim Exit Device. CD33/35A Rim Exit Device EL33/35A Rim Exit Device SS33/35A Rim Exit Device

Melamine Plastic Laminate. Toilet Partition Installation Manual

*D-1030* 1 PARTS CHECK 8 REVERSING INSTRUCTIONS F-XX-C & XX-C D Customer Service. Installation Instructions. Exit Devices

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2

ED5800 (A) Series. Installation Instructions. Concealed Vertical Rod. Exit Device WARNING

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

7110(F), 7170(F)(LBR) Surface Vertical Rod Exit Device Series Installation Instructions

Active Push Bar. Safety glasses Measuring tape Level Pencil Power drill Drill bits: 5/32, 3/4 Center punch Phillips screw driver

INSTRUCTIONS TS93 GSR PT RIGHT HAND ACTIVE LEFT HAND INACTIVE RIGHT HAND INACTIVE LEFT HAND ACTIVE

Installation Instructions

33/3527A. Devices covered by these instructions: 33/3527A-F (Fire) Surface Vertical Rod Exit Device

Table of Contents IMPORTANT

ED1100 /1100F SERIES RIM EXIT DEVICE INSTALLATION INSTRUCTIONS

RH-412 STEEL DOORS INSTALLATION INSTRUCTIONS

D3976 RECESSED EXIT INSTALLATION INSTRUCTIONS

1530(F) Mortise Exit Devices Installation Instructions

INSTALLATION INSTRUCTIONS RH 412 STEEL DOORS

Shim (2) Supplied. Strike Plate. (3) x 5/8" PFHMS or 10 x 1" PFHWS. Top Latch. (3) x 1/4" PRHMS. Latch Cover. (2) 8 x 3/8" PFH AB SMS

Installing Your Electronic Deadbolt

Installation Type. Edge of Door. Pull (Hinge) Side Mounted. Hinge Edge of Door. Push (Stop) Side Mounted

Installation Instructions FE6800 Series Multi-Point Lock

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET

Introduction. Rocky Mountain Westy Swing Away Carrier Kit Installation Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions

INSTALLATION INSTRUCTIONS CRL JACKSON

Installation Instructions

Note: The dimensions of the Template are shown in inches. See attached page for the Metric Conversion Table for millimeters.

GlideRite Retractable Cover System For Hot Spot Spas (SE & SLX only)

CONCEALED ROD CRASH BAR PR-7085 SERIES EXIT DEVICE ASSEMBLY DETAILS PR mm. 10mm. Lock cylinder. 10mm. Cross bar length (see note #8) Dogging

WD WD7000 Series

Installation Instructions. Installation Type

INSTALLATION INSTRUCTIONS

Calf-Tel Pen System Assembly Instructions

Installation Instructions. Installation Type

INSTALLATION INSTRUCTIONS

6 BAY AV CREDENZA WITH DUAL DISPLAY MOUNT

Installation Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions

INSTALLATION INSTRUCTIONS

INS T A L L A TIO N INS T R U C TIO N S HORSESHOE W/ BAR HANGER

WPS crew Doors Installation instructions

4600 Series Rim Narrow Stile Exit Device Installation Instructions I-ED01162

CONCEALED VERTICAL ROD PANIC EXIT DEVICE

BEFORE STARTING INSTALLATION

ASSA ABLOY Series Installation Instructions. Regular Arm. Parallel Arm. Top Jamb Mount. Multi-Sized 1 thru 6 Non-Hold Open and Hold Open Models

INSTALLATION INSTRUCTIONS

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)

LOFT DOOR HANGER BARN DOORS & HARDWARE. Hardware Installation Instructions. Page

EUROLINE CLASSIC SOLID SURFACE Installation Instructions

ED5200(A) Series Rim Exit Devices

INSTALLATION INSTRUCTIONS CRL JACKSON

INSTALLATION INSTRUCTION

INSTALLATION INSTRUCTIONS INS T A L L A TIO N INS T R U C TIO N S ROD IRON SCROLL HANGER R H

Heavy-Duty Bypass Track System

BioPrism Solid Surface

TIRE RACK INSTALLATION INSTRUCTIONS Dodge Sprinter

WAREHOUSE HANGER INSTALLATION INSTRUCTIONS R H INS T A L L A TIO N INS T R U C TIO N S

* * 98/9950WDC. Fire-Rated Devices include these. additional components. 1-Point Latch (LBL)

8800 Series Mortise Lockset Knob, Lever, Reflections and Security Trims Installation Instructions

INSTALLATION INSTRUCTIONS CRL JACKSON

#916 CLASSIC 16 GUN CABINET ASSEMBLY INSTRUCTIONS

For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY.

ASSA ABLOY. Installation Instructions. MP9800 Series Multi-Point Lock. MP9800 Series Multi-Point Lock Wood Doors. Wood Doors ASSA ABLOY.

Installation *HDWL-INSTR-001* IMPORTANT. Plastic Laminate Restroom Partitions Floor-Mounted with Overhead Brace Series 400

4 BAY Low Profile WALL MOUNT CABINET

EUROLINE CLASSIC PHENOLIC / EVERGREEN. Installation Instructions. Installation Instructions.

4 BAY Low Profile-Dual Displays WALL MOUNT CABINET

Table of Contents IMPORTANT

98/ Customer Service # Dogging Key (use to lock down pushbar)

How To Measure Your Finished Opening

Installation Instructions for 45H & 47H Mortise Locks

IMPORTANT: installation. FLOOR ANCHORED CEILING HUNG OVERHEAD BRACED FLOOR-TO- CEILING ANCHORED

INSTALLATION INSTRUCTIONS INS T A L L A TIO N INS T R U C TIO N S THE MAVERICK HANGER R H

4 BAY Low Profile - SINGLE XL DISPLAY WALL MOUNT CABINET

Installation. *HDWC-INSTR-007* HDWC-INSTR-007 Rev. K; ECN G 2018 Bradley Page 1 of 24 3/22/2018

3 BAY AV CREDENZA WITH SINGLE DISPLAY MOUNT

INSTALLATION INSTRUCTIONS

Sapper XYZ 30 Monitor Arm Installation Instructions

INSTRUCTION SHEET U19

Installation Instructions For The 8850FL Series Mortise eboss

Installation and Assembly - Articulating Swivel Double-Arm for 42" - 71" Plasma Screens

Stage 2: Preparing the door (read in conjunction with Hole Drilling Options on back of Template).

INSTALLATION INSTRUCTIONS FOR VERTICAL ROD ASSEMBLY, MODEL VRA-143

INSTALLATION INSTRUCTIONS

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

DC3210. Recommended Closer Size

Setup. The Faraday Cage is available in two types of configurations. Cage for mounting to a full perimeter enclosure on series tables.

OUTSIDE STRIKE INSIDE. TEMPLATE-S6100 Devices covered by this template: Panic Rim Device and Fire Rim Device. FINISHED FLOOR

Dublin Stalls Installation Instructions

INSTALLATION INSTRUCTION

Door Hardware Installation Instructions. For Assistance Call:

INSTALLATION INSTRUCTIONS VENETIAN 84" SLIDING SHOWER DOOR SYSTEM (180º INSTALLATION)

Transcription:

5mm Hex Nut Upper Telescoping hannel & Screws Packing List QTY. ITM 1 Top Telescoping hannel 1 ottom Telescoping hannel w/ self drilling screw 15" 18" 1 Top and ottom Rod with connecting arm 25-½ 2 ¼ - 20 x 2 ¾ arriage olts w/ stamped washers 18" Lower Telescoping hannel & Screws 25-1/2" 15" F G H I K F G H I J 2 ¼ - 20 corn ap Nuts 2 ¼ - 20 K Lock Nuts 2 Stamped Washers 2 ¼ Flat Washers 2 ¼ - 20 corn ap Nuts 2 ¼ - 20 K Lock Nuts SSRLS / SSRLU ardboard Template Z L LH RH N J K L M 2 ¼ - 20 x 2 ½ arriage olts 1 Upper Module w/ 5mm Hex Nut 1 Special Top Module over w/ Plastic cap N 1 Lower Module w/ 5mm Hex Nut M O O 1 Special Lower Module over w/ Plastic cap P 1 Main Lock ody w/ (2) Rod Holders Q 4 Stamped Washers P For Supervised Model (SSRLS) For Unsupervised Model (SSRLU) Q W U-Pin Y R S T U V W 2 ¼ - 20 K Lock Nuts 2 ¼ - 20 5mm Hex Nuts 2 #14 x 1- ½ Hex head washer self drilling screws 2 ¼ - 20 x 1 ¾ arriage olts 2 ¼ - 20 x 3 ¼ arriage olts 2 U-Pins R S T U V X ridge lip 49SLS-109 Strike X Y Z 2 ridge lips 1 49SLS-109 Strike- #14 x 1-½ TK HWH Screws and #8 x 5/8 TK HWH screws 1 ardboard template IMPORTNT: Out-swing models require SSRL-SK3 strike kit ST SS SYSTMS Product Line of Stanley Security Solutions, Inc., Indianapolis, IN 46250 (800)-392-5209 INS SSRLS_SSRLU-3 v10.2.vsd reated: 7/11/2013 Revised: 7/11/2013 INS0000113-01 Page 1

1-½ luminium ngle hannel OUT SWING MOL OUT-SWING MOL Upper Module The locksets are handed. When unlocked, the lever should always point upward at a 45 angle. 3- Point Horizontal Lock Installation Stamped Washer Main Lock ody OOR MRKING & RILLING: IMPORTNT: Make sure the door swings free and smooth before you begin the installation. Remove all old locks, exit devices, any slide bolts or other hardware & brackets. Make sure any exposed holes left from previous hardware are completely covered after installation. arriage olt & Washer ssly. Make any adjustments to make the door swing FRLY before you start marking and installing. Lower Module 1) Mark a horizontal reference line on the corridor side of the door, at a height of from the bottom of the door (not floor). xtend the line to the hinge side of the door. 2) Line up the template with the horizontal reference line and the door edge then tape it to the door. Please refer the cardboard template to mark and drill the holes. rill (4) 3/8" through holes (TIP: Start with 1/8"). Make sure you drill level. Stamped Washer & arriage olt ssly. Stamped Washer ORRIOR SI OF TH OOR OUT-SWING MOL 3) Select a location for the height of the top module (suggested at a height of 25-1/8" from the horizontal reference line). Mark a horizontal line approx. 12" from the lock edge of the door. Make sure the line is level. 4) Select a location for the height of the bottom module (suggested at a height of 35-1/8" from the horizontal reference line). Mark a horizontal line approx. 12" from the lock edge of the door. Make sure the line is level. ROOM SI OF TH OOR OUT-SWING MOL 4-½ ardboard Template 5) raw two vertical lines, one at a distance of 1-½ and another at a distance of 4-½ from door edge on the top and bottom horizontal module lines. 6) Punch the center point at vertical and horizontal lines intersect as shown. rill pilot holes first. rill (2) top holes and (2) bottom holes of 3/8" dia. through the door. SSRLS / SSRLU ardboard Template 4-½ ardboard Template 1-½ ORRIOR SI OF TH OOR ROOM SI OF TH OOR INS SSRLS_SSRLU-3 v10.2.vsd reated: 7/11/2013 Revised: 7/11/2013 Page 2

35 1/8 Frame 2-3/16 Main olt Strike Frame IN SWING MOL Upper Module IN-SWING MOL The locksets are handed. When unlocked, the lever should always point upward. 3- Point Horizontal Lock Installation Stamped Washer Main Lock ody OOR MRKING & RILLING: IMPORTNT: Make sure the door swings free and smooth before you begin the installation. Remove all old locks, exit devices, any slide bolts or other hardware & brackets. Make sure any exposed holes left from previous hardware are completely covered after installation. arriage olt & Washer ssly. Lower Module ORRIOR SI OF TH OOR IN-SWING MOL Main Lock ody Make any adjustments to make the door swing FRLY before you start marking and installing. 1) Mark a horizontal reference line on the corridor side of the door, at a height of from the bottom of the door (not floor). xtend the line to the hinge side of the door. 2) lign the template with the horizontal reference line and the frame stop then tape it to the door. Please refer the cardboard template to mark and drill the holes. rill (4) 3/8" through holes (TIP: Start with 1/8"). Make sure you drill level. 5) Select a location for the height of the top module (suggested at a height of 25-1/8"" from the horizontal reference line). Mark a horizontal line approx. 12" from the lock edge of the door. Make sure the line is level. 6) Select a location for the height of the bottom module (suggested at a height of 35-18' from the horizontal reference line). Mark a horizontal line approx. 12" from the lock edge of the door. Make sure the line is level. Stamped Washer & arriage olt ssly. ROOM SI OF TH OOR IN-SWING MOL 5-3/16" Stamped Washer 7) raw two vertical lines, one at a distance of 2-3/16" and another at a distance of 5-3/16 from frame stop on the top and bottom horizontal module lines. 8) Punch the center point at vertical and horizontal lines intersect as shown. rill pilot holes first. rill (2) top holes and (2) bottom holes of 3/8" dia. through the door. ardboard Template SSRLS / SSRLU ardboard Template 5-3/16" 2-3/16" ORRIOR SI OF TH OOR ROOM SI OF TH OOR INS SSRLS_SSRLU-3 v10.2.vsd reated: 7/11/2013 Revised: 7/11/2013 Page 3

OUT-SWING MOL OUT-SWING MOL Lock ody ORRIOR SI OF TH OOR ROOM SI OF TH OOR LOK OY INSTLLTION 1) lign the mounting plate of the lock body with (4) drilled holes on the door. Install Fasteners as follows: 2) Lock ody Front Holes: (2) 2-¾ long carriage bolts & washer ssly., k-lock nuts & acorn caps. arriage bolts & washer ssly. thru door, K Lock nut and corn cap Nuts 3) Lock ody Rear Holes: (2) 2-½ long carriage bolts, stamped washers, Flat Washers, k-lock nuts & acorn nuts. Flat Washers, K Lock nut and acorn caps Lock ody Important Note: o not compress the door. 4) Rotate lever to make sure bolts extend and retract smoothly. Make sure the main bolt is extended before next step. INS SSRLS_SSRLU-3 v10.2.vsd reated: 7/11/2013 Revised: 7/11/2013 Page 4

TOP MOUL INSTLLTION Use a level on the interior module and exterior thru-bolt plate to ensure module is level. Fasten module to door with (2) stamped washer and carriage bolts, from the exterior. Tighten 1/4"-20 K Lock Nut and then tighten 5mm hex nut securely. Once level, secure in place with #14 self-drilling screw in recess as shown. Slide the channel (both overlapping segments of the channel) over the vertical rod. The crimped wide end of the channel should point towards the lock body. Slide the upper narrow segment of the channel down to reveal the vertical rod with loop. ( Note: Loop on the vertical rod should always face towards the hinge side of the door as shown ). onnect the top portion of the vertical rod with loop to the module by removing the bridge clip and placing the loop on the rod over the connecting arm pin. Then replace the bridge clip. Slide upper segment of the channel up to conceal the vertical rod and insert it into upper module. pproximately ½ of channel should rest on top module back plate. The crimped segment should fit snugly into the lock body housing. Vertical rod with loop 5mm Hex Nut #14 Self rilling Screw Slide the crimped segment of the channel up to reveal the slotted end of the rod. Hook the rod holder into the slots on the rod. Use the Quick onnect Pin to secure them together. F Fasten both overlapping segments of the channels together with self-drilling screw on the side. G Place cover over module and channel. Insert and secure llen key threaded cap nut. OTTOM MOUL INSTLLTION Repeat above steps for bottom module installation. LHR Hinge Side of the oor Hinge Side of the oor RHR Vertical rod with loop ridge lip F onnecting rm Pin Loop Loop onnecting rm Pin Quick onnect Pin Rod Holder G Narrow nd hannel rimped Wide nd hannel INS SSRLS_SSRLU-3 v10.2.vsd reated: 7/11/2013 Revised: 7/11/2013 Page 5

luminium ngle hannel OUT-SWING MOL OUT-SWING: Upper Module Lower Module Inswing: Main Lock ody LUMINUM NGL INSTLLTION 1) lose the door first! Line up the edge of the aluminum angle with edge of the frame and strike opening with main bolt as shown. Make sure olts are not rubbing and door can open easily. 2) Fasten the aluminum angle to the frame with #14 hex head self drilling screws. 3) Keeping the door pulled against the door stop, extend the bolts as much as possible. Trace the outline of the top and bottom bolts &. 4) Open the door and mark the centers of the top and bottom holes. enter punch the point to be drilled. rill a 1/8" pilot hole first and then enlarge to ¾ and remove all burrs. The dead bolt dia. Is 5/8". ¾ hole, if drilled on center, should be sufficient. If you feel any rubbing, check to see which part of the bolt is rubbing in the hole and grind or enlarge that side of the hole. 5) Mount strike to the aluminum angle with ¼ - 20 flat head Phillips screws and ¼-20 K-Lock nuts. So, that roller faces you and is flush with aluminum angle as shown in. djust so that main bolt operates smoothly and tighten the K-Lock nuts completely. 6) heck lock for the smooth operation. Top & ottom olt Hole luminum ngle ¼ - 20 K-Lock Nut Strike Opening luminium ngle ¼ - 20 Flat Head Phillips Screw 1) xtend the bolts and draw center line for the bolt. 2) Using a chisel, chop out the rectangle 1" x 1-3/4".e sure the box can be placed at least ¾ deep into stop. 3) File the edges smooth. 4) Install the Main eadbolt Strike Place the box strike into the hole. Mark and drill 1/8 pilot holes at the oval inner holes. Fasten the strike loosely with the 2 large self-drilling hex head screws. djust sideways as needed so the bolt moves freely before tightening the screws completely. 5) fter making the final strike position adjustment, insert the 2 small slot-hex head sheet metal screws into round outer holes to secure. ST SS SYSTMS Product Line of Stanley Security Solutions, Inc Indianapolis, IN 46250, (800)-392-5209 INS SSRLS_SSRLU-3 v10.2.vsd reated: 7/11/2013 Revised: 7/11/2013 Page 6

oor Stop IN-SWING: INSTLL MOUL STRIK PLT: Keeping the door pulled against the door stop, extend the bolts as much as possible. Trace the outline of the top and bottom deadbolts onto the frame. 1 Open the door and mark the centers of the top and bottom deadbolt holes. enter punch point to be drilled. rill 1/8" pilot hole first and then enlarge the deadbolt center hole ¾ and remove all burrs. The deadbolt dia. is 5/8". ¾ hole, if drilled on center, should be sufficient. If you feel any rubbing, check to see which part of the bolt is rubbing in the hole and grind or enlarge that side of the hole. Line up the module strike plate with center drilled hole. Mark the centers of the (2) holes for the top and bottom module strike plate. rill 1/8" pilot holes first as shown. Fasten the top and bottom module strike plate with (4) #8 Flat Phillips thread cutting screws. heck lock for the smooth operation. 2 eadbolt enter Hole 2 4 #8 Flat Phillips Thread utting Screws Module Strike Plate 3 Module Strike Plate Holes ST SS SYSTMS Product Line of Stanley Security Solutions, Inc Indianapolis, IN 46250 (800)-392-5209 INS SSRLS_SSRLU-3 v10.2.vsd reated: 7/11/2013 Revised: 7/11/2013 Page 7

LH / LHR OORS - THIS SI UP LIGN WITH FRM STOP FOR INSWING OORS SSRLS / SSRLU SRIS TMPLT ST SS SYSTMS PROUT LIN OF STNLYSURITY SOLUTIONS, IN., ININPOLIS, IN - 46250, (800)-392-5209 SSRLS / SSRLU MOUNTING TMPLT RV 10.31.2010 LIGN WITH OOR G FOR OUTSWING OORS RILL N NLRG TO 3/8" 4 PLS RILL N NLRG TO 3/8" 4 PLS FOR OUTSWING MOLS: FOL OR UT LONG THIS LIN FOR OUTSWING MOLS: FOL OR UT LONG THIS LIN RH / RHR OORS - THIS SI UP LIGN WITH OOR G FOR OUTSWING OORS LIGN WITH FRM STOP FOR INSWING OORS