Installation Instructions Model # TEL-100 / 200 Manual Locking or Self Locking

Similar documents
SSRLS-3 / SSRLU-3 Installation Instructions

Packing List MODEL TEL-IAL-481 For Inactive Leaf TRIDENT double door

SECURITECH GROUP, INC. MP POLICE LOCK. MODEL 4840B-TTBG_HG-3_ or 4840B-TTBG_HG-4_. Packing List. Documentation: Items: Fasteners:

MP Panic Exit Police Lock. Review Of March 2004 Installation

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

INSTRUCTIONS TS93 GSR PT RIGHT HAND ACTIVE LEFT HAND INACTIVE RIGHT HAND INACTIVE LEFT HAND ACTIVE

33/35A Series. Devices covered by these instructions: Rim Exit Device. CD33/35A Rim Exit Device EL33/35A Rim Exit Device SS33/35A Rim Exit Device

98/9927. Devices covered by these instructions: Surface Vertical Rod Exit Device

33/3527A. Devices covered by these instructions: 33/3527A-F (Fire) Surface Vertical Rod Exit Device

CONCEALED VERTICAL ROD PANIC EXIT DEVICE

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET

Safety glasses Measuring tape Level Pencil Power drill Center punch Phillips screw driver Saw horse

Entry Mortise Handleset

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2

INSTALLATION INSTRUCTIONS RH 412 STEEL DOORS

ED1100 /1100F SERIES RIM EXIT DEVICE INSTALLATION INSTRUCTIONS

RH-412 STEEL DOORS INSTALLATION INSTRUCTIONS

INSTRUCTION SHEET U19

TIRE RACK INSTALLATION INSTRUCTIONS Dodge Sprinter

Introduction. Rocky Mountain Westy Swing Away Carrier Kit Installation Instructions

INSTALLATION INSTRUCTIONS CRL JACKSON

Privacy Wall Glass Selections - Polished Edge Slider Door

D3976 RECESSED EXIT INSTALLATION INSTRUCTIONS

Active Push Bar. Safety glasses Measuring tape Level Pencil Power drill Drill bits: 5/32, 3/4 Center punch Phillips screw driver

Note: The dimensions of the Template are shown in inches. See attached page for the Metric Conversion Table for millimeters.

For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY.

INSTALLATION INSTRUCTIONS FOR VERTICAL ROD ASSEMBLY, MODEL VRA-143

How To Measure Your Finished Opening

1530(F) Mortise Exit Devices Installation Instructions

Installation Instructions

Installing Your Electronic Deadbolt

Installing the Profile Privacy Panel. Assemble top mounting bracket. Prerequisites. Tools

FIGURE 1, TYPE B Active leaf opens both doors. Overlap plates installed on the inactive

LOFT DOOR HANGER BARN DOORS & HARDWARE. Hardware Installation Instructions. Page

Heavy-Duty Bypass Track System

INSTALLATION INSTRUCTIONS CRL JACKSON

*D-1030* 1 PARTS CHECK 8 REVERSING INSTRUCTIONS F-XX-C & XX-C D Customer Service. Installation Instructions. Exit Devices

INS T A L L A TIO N INS T R U C TIO N S HORSESHOE W/ BAR HANGER

INSTRUCTIONS FOR 1431 Door Closer with Hold Open Arms 1431 SERIES ADJUSTABLE FROM SIZE 1 THRU 6

Installation Instructions For The 8850FL Series Mortise eboss

GlideRite Retractable Cover System For Hot Spot Spas (SE & SLX only)

8800 Series Mortise Lockset Knob, Lever, Reflections and Security Trims Installation Instructions

EXIT DEVICE OPERATION FIRE DOOR LABELS, STRIKES AND FRAME SCREWS FOR INFORMATION CALL OR VISIT RITEDOOR.COM

4600 Series Rim Narrow Stile Exit Device Installation Instructions I-ED01162

Door Hardware Installation Instructions. For Assistance Call:

CONCEALED ROD CRASH BAR PR-7085 SERIES EXIT DEVICE ASSEMBLY DETAILS PR mm. 10mm. Lock cylinder. 10mm. Cross bar length (see note #8) Dogging

WAREHOUSE HANGER INSTALLATION INSTRUCTIONS R H INS T A L L A TIO N INS T R U C TIO N S

351 DOOR CLOSER WITH DOUBLE LEVER ARM (OP) INSTALLATION INSTRUCTIONS

EZ-MATRIX I N S TA L L AT I O N I N S T R U C T I O N S EZ-MATRIX

INSTALLATION INSTRUCTIONS CRL JACKSON

TABLE OF CONTENTS REQUIRED TOOLS

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INS T A L L A TIO N INS T R U C TIO N S THE MAVERICK HANGER R H

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

WPS crew Doors Installation instructions

INSTALLATION INSTRUCTIONS FOR PLASCORE NARROW STILE DOORS

6 BAY AV CREDENZA WITH DUAL DISPLAY MOUNT

4-lite Patio Door. Installation Instructions

INSTALLATION INSTRUCTIONS GT1006E TALL CABINET, RESIN WALL MOUNT

Linear Hook- on Worksurfaces

INSTALLATION INSTRUCTIONS INS T A L L A TIO N INS T R U C TIO N S ROD IRON SCROLL HANGER R H

4 BAY Low Profile-Dual Displays WALL MOUNT CABINET

INSTALLATION INSTRUCTIONS

GlideRite Retractable Cover System For HotSpring & Tiger River Spas (except Classic & pre-2000 Landmark Spas)

RBP-1215B-RX DODGE RAM QUAD CAB RX3

PRO / PL SHOE REPLACEMENT & CONVERSION INSTRUCTIONS

v1.0 ASSEMBLY GUIDE Mia Wide Bookcase

BioPrism Solid Surface

INSTALLATION INSTRUCTIONS

* * 22 & 22-F. Please give these instructions to building owner after device is installed BS EN 1125 : 2008

WD WD7000 Series

Assembly Instructions

ICU TRACKLESS SLIDING DOOR

Stage 2: Preparing the door (read in conjunction with Hole Drilling Options on back of Template).

INSTALLATION INSTRUCTIONS

INSTALL INSTRUCTIONS WELCOME TO THE NEWAGE PERFORMANCE CABINETRY SERIES NEWAGE STEEL WELDED CABINETRY

Installation Instructions - Model V4JSD 1

Retractable Screen Installation Instructions For Vinyl and Aluminum Clad and Wood In-Swing Hinged Doors (See separate instructions for sliding doors)

4 BAY Low Profile WALL MOUNT CABINET

Dublin Stalls Installation Instructions

ALDoor DOUBLE DOOR INSTALLATION

** Do Not Contact the Store ** For Assistance, including missing or broken parts, Call Customer Service at:

Before fitting door, check opening size and squareness of timber frame. The door is made smaller to give correct clearance within the frame.

ASSA ABLOY. Installation Instructions. MP9800 Series Multi-Point Lock. MP9800 Series Multi-Point Lock Wood Doors. Wood Doors ASSA ABLOY.

Shetland Stalls Installation Instructions

INSTALLATION INSTRUCTION

Privacy Wall & Glass Selections Pivot-Hinged Door (For products manufactured after September 14, 2009)

Setup. The Faraday Cage is available in two types of configurations. Cage for mounting to a full perimeter enclosure on series tables.

ED5200(A) Series Rim Exit Devices

Mounting a BalanceBox 400 to a brick wall

MORTISE LOCK INSTALLATION INSTRUCTIONS

TOYOTA MOTOR EUROPE CA Products Division Tel : Fax :

DC3210. Recommended Closer Size

SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUH (HOLD OPEN) ARMS

LF Series Assembly Instructions

Installation Type. Edge of Door. Pull (Hinge) Side Mounted. Hinge Edge of Door. Push (Stop) Side Mounted

D2/367A ASSEMBLY INSTRUCTIONS 6 BAY AV CREDENZA. Salamander 6 Bay AV Credenza [5.17] page 1 of 8

* * 98/9950WDC. Fire-Rated Devices include these. additional components. 1-Point Latch (LBL)

Assembly Instructions Nevins Phone Booth

Installation Instructions

Transcription:

INSTLLTION INSTRUTIONS TL-100 / 200 GSS-oors TL 1-406-212-2334 MIL rg@gssdoors.com W www.gssdoors.com GSS oors (406) 212-2334 (406) 897-2121 rg@gssdoors.com www.gssdoors.com TM Multi-Point eadbolt Installation Instructions Model # TL-100 / 200 Manual Locking or Self Locking PLS RVIW PRTS & INSTRUTIONS FOR INSTLLING INS TL100_200 v9.4.vsd reated: 6/2/2015 Revised:6/2/2015 INS0000207-01 v1.0 Page 1

nti-pry Plate & Lock Thru-olts nti-pry Plate Fasteners Top & ottom Module Thru-olt Plates Strike Plate ag HS N ISONTINU TRINT Tools Required: eadbolt TL-100 / 200 PRTS LIST GSS oors (406) 212-2334 (406) 897-2121 rg@gssdoors.com www.gssdoors.com ag ag ag (1) 13" nti Pry Plate Part# TL--PP-1 * If installing exterior entry elements, see note below (4) 1/4"-20 K lock nuts (4) 1/4"-20 acorn cap nuts (2) 1/4"-20 x 2-½ carriage bolts (ack) (2) 1/4"-20 x 2-¾ carriage bolts (Front) (2) 1/4" Flat washers (ack) (2) 1/4"-20 Hex head T-nuts (2) Thru olt Plates (Upper & Lower)- (2) 1/4"-20 x 2" arriage olts (2) 1/4"-20 x 3-1/4" arriage olts (2) 1/4"-20 K Lock Nuts (2) 1/4"-20 5mm Hex head T-nuts (2) #14 x1-½ Hex head washer selfdrilling screws for positioning modules (1) Strike plate- (2) #14 x1-½ Hex head washer self drilling screws (2) Self drilling sheet metal screws for positioning- For ouble oor Installations, see Parts and INS PLS HK TO MK SUR YOU HV LL PRTS FOR STRTING TH INSTLLTION Hammer rill enter Punch 7/16" Nut river 5mm Hex key Template Lock Mechanism & Modules Module overs & hannels 1/8" rill bit ¼ rill bit ¾ rill bit 3/8" rill bit Masonry ¾ rill bit Philips head screw driver (1) luminum oor Template (LH & RH) (1) Self drilling screw (taped to label) ssembled Main Lock ody Top & ottom Modules (with cables) (Manual or Self- Locking Lock ody) (2) luminum hannels w/feet (1) RH Module cover (1) LH Module cover Paddle ag (1) xit Paddle (2) 12-24x7/8" arriage olts 1 (2) 12-24 Hex Nuts Pull Handle Hinge Side olt ag F ag G TL- 100 Models ONLY (1) luminum Pull Handle- 11-PH (2) ½ Pan Philips Sheet Metal screws- 08PPSM5 (1) Hinge Side olt (2) 1/4"-20 K lock nuts * If installing xterior Key ontrol, item & ag have been replaced with items on xterior Trim sheet. Please follow instructions provided. (2) 1/4"-20 acorn cap nuts (2) 1/4"-20 x 2-1/2" carriage bolts (1) Thru-bolt Plate Illustrations in instructions may vary from actual parts supplied. INS TL100_200 v9.4.vsd reated: 6/2/2015 Revised:6/2/2015 J Page 2

TRINT GSS OORS (406) 212-2334 (406) 897-2121 rg@gssdoors.com www.gssdoors.com Fig.1 FOR YOU GIN: Make sure the door swings free and smooth. Remove all old locks, exit devices, any slide bolts or other hardware and brackets. Make sure any exposed holes left from previous hardware are completely covered after installation. Insert material into the mortise opening to prevent collapsing or squeezing. ** RMOV NY WTHR-STRIPPING ON TH OOR OR FRM NOW.** TL-200 series Self-locking Tridents require a door closer to be installed. If Installing On ouble oor, Refer to TL-IL/IT INSTRUTIONS NOW Single oor Vertical Line Horizontal Line eadbolt ouble oor Option if needed 1. oor Marking & rilling Fig.1 1. Stand inside & close the door; mark a vertical line along the frame stop along the entire length of door. 2. raw a horizontal line at a height of 45-½ from the bottom edge of the of door. If installing a double door model, draw the line at least 4" across to the inactive leaf. NOT: The height of the line can be adjusted to cover any cylinder holes or exit device holes. The Trident should always be installed at a height that meets applicable code. Fig.2 3. Place the top corner of the metal marking template at the intersection where the horizontal line and vertical line meet. Make sure template is level. 45-½ Horizontal Line 45-½ Fig.2 Vertical Line M 4. Mark hole. Remove template and center punch. Fasten template to door with #8 self-drilling sheet metal screw through hole in metal template and into the door. 5. lign the top edge of the template with the horizontal line then mark 6 holes H on lock edge. Mark hole M Fig.3 6. Swing template down vertically and mark bottom 2 holes then swing template up vertically and mark top 2 holes F Make sure template is always aligned with vertical reference line when marking top & bottom holes. Fig.4 7. Remove the template. Punch the center point for all Fig.5 marked holes. rill all 1/8" dia. pilot holes G MK SUR YOUR RILL IS LVL WHN YOU R RILLING HOLS. 8. rill ten holes 3/8" dia. through the door H and 9. rill up to 1-5/16" diameter hole through the door at M now for exterior lever trim spindle or for future use even if not installing lever trim at this time. See separate xterior Key ontrol Instructions and parts list. I ottom of oor INS TL100_200 v9.4.vsd reated: 6/2/2015 Revised:6/2/2015 J Page 3 Fig.3 F Fig.4 Top of oor G rill all 1/8" dia. pilot holes Hinge side of door M H Fig.5 M I I 6 HOLS H F 6 HOLS

2. Lock ody: GSS OORS (406) 212-2334 (406) 897-2121 rg@gssdoors.com www.gssdoors.com ag TRINT eadbolt Hex-Head T-nut cap screws K Lock nut Fasten the anti-pry plate with two 5mm Hex-head T-nut cap screws. o not tighten completely. lign the lock body with the top of the horizontal reference line, using a level to ensure the mechanism is level, then fasten as follows: Interior view Front Holes: 2-3/4 long carriage bolts, k-lock nuts & acorn caps Rear Holes: 2-1/2 long carriage bolts, flat washers, k-lock nuts & acorn nuts Tighten allen-head T-nut cap screws completely. o not compress door. xterior view corn ap Nuts carriage bolts thru door 3. Top & ottom olt Modules: ag xtend main bolt by pulling paddle or pressing trigger. Refer photos to steps below. TOP MOUL arriage bolt integral T-nut integral 5mm Hex head T-nut K-Lock nut #14 Self rilling Screw Fasten integral 5mm Hex head T-nut with the 2 carriage bolt through the thru-bolt plate. Fasten loosely. Secure k-locknut to 3-1/4 carriage bolt on lock edge opening and fasten loosely. Tighten the integral 5mm Hex head T-nut securely using a 5mm Hex key. Use a level before tightening. Tighten K-locknut securely to 3-¼ carriage bolt. Once level, secure #14 self drilling screw. heck for smooth operation OTTOM MOUL Repeat steps for bottom module. Manual Locking Models: Push and pull paddle arm Self-Locking Models: Press trigger & push paddle arm. Make sure bolts extend past vertical reference line. INS TL100_200 v9.4.vsd reated: 6/2/2015 Revised:6/2/2015 J Page 4

GSS OORS (406) 212-2334 (406) 897-2121 rg@gssdoors.com www.gssdoors.com Retract the bolt by pressing the paddle. lose the door. TRINT eadbolt 4. Main Strike Plate: ag Hold the strike plate against the frame with roller facing towards the outside. xtend bolt and center in strike box. Top of bolt should be approx. 1/8" from top of strike opening. Trace the outline of strike box on frame. Open door, align strike in outline. Make sure strike is level. Mark top and bottom strike plate oval mounting holes. Remove the strike plate and mark the center of each oval. enter punch the mark. rill 1/8" diameter pilot holes. Fasten strike to door with the self-drilling #14x1-½ screws. Install 2 rear self-drilling screws. 5. Marking & rilling Frame For Top & ottom olts Pull the door closed and extend the bolts as much as possible. Keeping the door pulled against the door stop, trace the outline of the top and bottom bolts. Open the door and mark the centers of the holes. enter punch the point to be drilled. rill a 1/8" pilot hole. nlarge to 3/4 and remove all burrs. The deadbolt diameter is 5/8" 3/4 hole, if drilled on center, should be sufficient. If you feel any rubbing, check to see which part of the bolt is rubbing on the hole and grind or enlarge that side of the hole. ½ Min. INS TL100_200 v9.4.vsd reated: 6/2/2015 Revised:6/2/2015 J Page 5

GSS OORS (406) 212-2334 (406) 897-2121 rg@gssdoors.com www.gssdoors.com 6. Paddle, hannels, Module overs & Pull Handle TRINT eadbolt Upper luminum hannel Paddle: ag Fasten the paddle to the paddle arm with small carriage bolts and nuts. **TL-P4 (18") or TL-P1 (24")- Rubber protector should be mounted 5" from the edge of the paddle on the surface of the door. hannels: Slide upper channel into lock body, center on cable. The two Flaps at the end of each channel should be near the main mounting plate. Used with TL-200F Rubber Protector Flaps must point towards main lock body FLPS FLPS Modules: ag : 5mm Hex Head T-nut Place cover over module and channel. Fit tail into cover slot and work into position. Insert hex head T-nut and fasten until secure. Repeat for lower module. Lower luminum hannel Pull Handle: ag F (TL-100 models only) Install pull handle on top channel approx. 8" above mounting plate using 2 self-drilling screws. 7. Hinge Side olt: ag G TIL 5mm Hex Head T-nut With door closed, mark vertical line approx. 4" long at the point where the stop overlaps onto the door. Height should be approx. 50" from floor (height can vary). With door open, place the Hinge-Side olt on door and recess 1/8" from the vertical line. Mark centers of thru-bolt holes. enter punch holes. rill 1/8" pilot hole. nlarge to 1/4". Remove all burrs. Fasten Hinge-Side olt to door with Thru-bolt plate, 2-1/2 carriage bolts lock washers and cap nuts. Mark bolt location on frame. rill up to 3/4" hole. It is usual for this hole to be gg shaped towards the outer edge of the door stop. Remove all burrs and check for smooth operation. 8. Optional larm omplete alarm installation instructions furnished with alarm ll TRINT alarms are installed after the lock has been installed. Use a flat head screwdriver to pop-off the jack cover. Mount the alarm or keyswitch to the wall at approx. 48" from floor. Run the armored cable on the wall, make a loop and run across the door, fastening with the mounting clips provided. INS TL100_200 v9.4.vsd reated: 6/2/2015 Revised:6/2/2015 J Page 6