Installation personnel should be familiar with applicable codes or established practices for their locale. Weather Reistant PVC Jacket

Similar documents
Loose Tube Cable End Preparation for Splicing For Series 11D, 1GD, 12D, 1AD, 1DD, 1CD, 11, 1G, 12, 12L, 1A, 1D, 1C, 1NY, 13, 1H, HZD and HZA

SECTION COMMUNICATIONS COPPER BACKBONE CABLING

AUTOMATIC WIRE STRIPPER CABLE CUTTING PLIERS WIRE STRIPPERS & CUTTERS SA822, CCP SPECIFICATIONS SPECIFICATIONS

Canadian OSP Copper I-1. Table of Contents

SECTION COMMUNICATIONS COPPER BACKBONE CABLING

GORE Aerospace Ethernet Cables

DRAFT. Sudden Ionospheric Disturbance (SID) Antenna Manual. Stanford Solar Center Stanford University Version 2.0

C MILLER "'";) ... MILLER TOOLS 925CS/925CS-ERGO CK6 925CS KIT .-.

Slack Span Dead-end. Slack Span Dead-end GENERAL RECOMMENDATIONS NOMENCLATURE 14-23

Kinetic Reflex T -Stripper Wire Stripper

C-L-X ARMOR REMOVAL PROCEDURES

Spiderbeam Balun Construction Guide

Detailed Specifications & Technical Data

14 AWG 2 AWG: 600 Volt

SECTION COMMUNICATIONS COPPER OSP CABLING

Ideal. Ergonomic, Cushion-Grip, Vinyl Coated

PAC-12 Kit Contents. Tools Needed Soldering iron Phillips screwdriver Wire stripper Wrenches, 7/16 and 1/2 Terminal crimp tool Pliers Solder

Band-Master ATS Nano Pneumatic Banding Tool Operating Instructions

Yellow 77 Plus Wire Pulling Lubricant. Yellow 77 Wire Pulling Lubricant. ClearGlide Wire Pulling Lubricant

STRENGTH Aligned teeth provide superior gripping power over standard vertical teeth. STRENGTH Diamond serrated jaws provide a firm grip

GORE Aerospace Ethernet Cables

Cable & Bolt Cutters. F o r P. r o f e. s s i o. n a l s. .. S i. n c e 1

Bel Stewart Connector

ClampStar Safe-T-Link Tether Installation Instructions for Deadends

CABLE & WIRE MILBAR SAFETY WIRE PRODUCTS

COYOTE Terminal Closure (Single Chamber) Hermetically Sealed With Hardened Adapters

Tool Sets. All dimensions are in inches and (millimeters). See page 310 for additional information on warnings.

Fiber Splice Box (FSB-D) Installation Instructions

Over 35 Years of Service. Our Commitment. Dedicated to Our Customers. Product Expertise and Specialized Services. Strategic Partnerships

Crimping and Cutting Tool for Connectors, Accommodates wire. From No. 10 to 22 Awg CRIMPING/CUTTING TOOL FOR CONNECTORS. from No.

Cable Hanging Instruction Manual

Instructions For Installing A Pig Fence

Coated Dead-end NOMENCLATURE GENERAL RECOMMENDATIONS

SKDG Cable Repair Kit Instructions

CARPENTER MACHINE SERIES

Electrical Characteristics Nominal electrical characteristics are shown in Table 1. Attenuation, Comply with ANSI T1.102; discrete values Table 1a.

Pliers. Pliers PLIERS

St. Monica Food Pantry Low Voltage (600V and less) Conductors and Cables sys-tek No

How to Hard- Wire your Zumo 665 to the Slingshot Infotainment Center

High Leverage Combination Pliers

2. Conductor insulation should be supported and gripped by the terminal.

Content. - DDF Frame Pair Screen Cable Pair Screen Cable

Torque Sensor Accessories and Services

ClearSpan End Frame Kit 30' Wide x 11' High

WIRE & CABLE FILS ET CÂBLES ALAMBRES Y CABLES. 63 Technical information. 64 Primary Wire. 66 Brake Cable & Portable Extension Cable

TERMINATION & SPLICING OF SHIELDED PRODUCTS

Field Installed Connectors for TraceTek 7000-HUV Bulk Cable Installation Instructions

SDE Standard Die Envelope

CIR (Crush & Impact Resistant) VFD Power Cable

BUILD A HIGH PERFORMANCE TWO ELEMENT TRI-BAND CUBICAL QUAD. By Bob Rosier K4OCE INTRODUCTION THEORY AND GENERAL INFORMATION

Color-Keyed. Compression Connector System. Table of Contents

TECHNICAL GUIDELINE. DIN Connectors and N Connectors Installation Guidelines Using Manual Cable Prep Tools. Table of Contents

Amphenol. Advantage. R-Line R-146. Rectangular Attached Multi-Pin Industrial Cable Assemblies. Amphenol - Sine Systems

Field Instrument Cable. Electrical Noise

STRIPPING-TOOL-SR-CABLE Stripping Tool for Raychem Self-Regulating Cable Operating Instructions

Understanding and Inspecting THE DIGITAL BUS. by Jim Sparks

Tool Sets. Tool Sets. 41-Piece Journeyman Tool Set. Cat. No. Set Contains Weight (lbs.) WARNING: Do NOT use screwdrivers to pry or chisel.

Some hints/tips on how to assemble nice COAX TRAPS!

EZ-200-NMH-D ok by tech Svcs

3.2.3 Rear Door Window and Quarter Window Carrier Assembly

NETWORK CONNECTIVITY SYSTEMS

Manual Version July 2007

WARNING EXTREME CARE MUST BE USED FOR YOUR SAFETY

Professional Pliers. Quality to Depend on

New Paladin Tools Products March 2010

PAWOMAT MACHINE SERIES

Page 1 of 5 Application Engineering Note Proc. 001 Interlock Armor and Corrugated Steel Tape Cables Pulling Grip Installation Procedure Rev.

ÖLFLEX. Lift & Crane Cable LIFT & CRANE CABLE

Wiring Techniques for Wiring a Lamp

Medium Voltage Power Cables

Creating. There is one basic question every customer needs to address when creating custom

Hendrix Tap, Tie & Ground Wire

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

Instrumentation Cables

METAL CLAD WIRING SYSTEM

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

FTTH ENGINEERING AND INSTALLATION INTRODUCTION

Overview The Thomas & Betts Method is Better. Just Four Easy Steps to a Perfect Connection! Step 1. Step 2

Tongue & Groove Slip Joint Diagonal Cutting Lineman s End Cutting Needle Nose Long Reach Locking Retaining Ring Wire Stripper Snips Pocket Knives

2 Recommended Tools / Supplies

A. Product Description: Stranded conductor insulated wire.

STORM FLEX 0 4 7, 0 8 6, & S E R I E S

UNCONTROLLED 3 STANDARD PROCEDURES FOR PREPARING 33KV CABLES

Install & Go Cat.8 S/FTP Trunk Cable Assembly Description

This specification describes termination procedures of AMP Netconnect Cat.6 Compact Patch Panel 0.5U:

Crimpers and Wire Prep Tools

Instruction Sheet Tool Kit [ ] (for SL Series 110 Jack Connectors)

Detailed Specifications & Technical Data

ELECTRICAL CABLE SPLICE KIT. Roctest Limited, All rights reserved.

Detailed Specifications & Technical Data

Nippon Antenna. Instruction Manual. Terrestrial Digital Antenna Thin-Style Indoor/Outdoor UHF Antenna. Connecting the cable. Accessories.

FLITZEBOGEN-2 Assembly instructions

Electrical Wiring Projects

Jewelry Basics 101. Basic Wire Loops For best results, use both chain-nose and round-nose pliers. Method 2 Bend then cut. Method 1 Cut then bend

TwenCombi Cat-5E FTP(3x) - Coax 9 - EIBA - tube PE 5 mm

Preparation and Installation Tools and Accessories

LMR-240. LMR -240 Flexible Low Loss Communications Coax TIMES MICROWAVE SYSTEMS

TR # Industrial Ethernet Torsion Test

31375 Aqua-Gel Ii, 5-Gal Bucket

Line Following Circuit Board Wiring Guide

Transcription:

ADP S / ADP NMS Application Guide Superior Essex manufactures a wide variety of designs and configurations of Outside Plant (OSP) cable and wire. This document provides installation recommendations for the ADP S (Aerial Shielded) and ADP NMS (Aerial Non-Shielded) service wire. Installation personnel should be familiar with applicable codes or established practices for their locale. ADP S MINOR AXIS Weather Reistant PVC Jacket 22 AWG Solid Annealed Copper Insulated Conductors Drain Wire Rip Cord Metallic Foil Shield MAJOR AXIS Non-Metallic Strength Members ADP NMS Weather Resistant PVC Jacket 22 AWG Solid Annealed Copper Insulated Conductor Rip Cord Non-Metallic Strength Members Page 1 of 6

Installation Practices There are certain limitations to shielded aerial service wire performance that must be respected during installation. In general, the four most critical characteristics are: tensile strength, bend radius, crush resistance, and temperature rating. These characteristics vary among wire types, sizes, and even manufacturers. It is critical for the designer and installer to be familiar with these criteria prior to installation start. Tensile Strength and Minimum Bend Radius Maximum Allowable Tension Pair Count 1-3-Pair ADP NMS and ADP S and ADP NMS Compact Design 6 X 24 5-6-Pair ADP NMS and ADP S GR-3163 CORE/ICEA 5-89-648 Short Term (Storm Loading) lbs (N) Long Term lbs (N) Minimum Bend Radius in (mm) 365 (1624) 80 (356) 3.25 (82.6) 475 (2113) 200 (890) 3.50 (76.2) Crush Resistance Crush resistance is an important attribute, which is easily quantifiable in a test laboratory, yet difficult to predict in an installation environment. Crushing a shielded aerial service wire can cause many issues from temporary, intermittent anomalies to permanent failure. The best rule is to avoid actions, routes, guides, mounting devices, etc., that deform the shape of the jacket. Temperature Ratings Temperature Range Environment F ( C) Storage -40 to +176 (-40 to +80) Install -30 to +140 (-22 to +60) Recommended Installation Tools Protective gloves Diagonal cutters (oblique pliers) Splicer s knife or splicer s/electricians snips (5 scissors) Needle-nose pliers (optional) Page 2 of 6

Installation Hardware Options Listed below are available drop clamps from several vendors that may be used in the installation of ADP S and ADS NMS service wire. Drop clamps that include dimpled shims are highly recommended, as they tend to minimize slippage. The design of ADP S aerial service wire requires the larger drop wire clamp to make attachments at poles, buildings or other distribution points, even with the 3-pair version. ADP S Third Party Manufacturer Description Part Number Pair count Thomas & Betts (Diamond/Sachs) Drop Wire Clamp Aluminum 23-4441 1-Pair Thomas & Betts (Diamond/Sachs) Drop Wire Clamp Aluminum 23-82351 3-5-Pair Senior Industries (MSI) Drop Wire Clamp Removable SI-0956 1-Pair Senior Industries (MSI) Drop Wire Clamp Removable SI-0966 3-5-Pair Allied Bolt, Inc. 3-5-Pair Drop Wire Clamp Dimpled Shim 909 1-Pair Allied Bolt, Inc. 3-5-Pair Drop Wire Clamp Dimpled Shim 963 3-5-Pair ADP NMS Third Party Manufacturer Description Part Number Thomas & Betts (Diamond/Sachs) 1-3 Pair Drop Wire Clamp Aluminum 23-8885 Thomas & Betts (Diamond/Sachs) 5-6 Pair Drop Wire Clamp - Aluminum 23-82351 Senior Industries (MSI) 1-3 Pair Drop Wire Clamp Stainless SI-0956 Senior Industries (MSI) 5-6 Pair Drop Wire Clamp - Stainless SI-0966 Allied Bolt, Inc. 1-2 Pair Drop Wire Clamp - Stainless 909 Allied Bolt, Inc. 3-6 Pair Drop Wire Clamp - Stainless 963 NOTE: Manufacturers installation recommendations should be followed. This list is believed accurate at time of publication and is provided for convenience purposes only. Always check current compatibility. ADP NMS Compact Design 6X24 Third Party Manufacturer Description Part Number Thomas & Betts (Diamond/Sachs) 6-Pair Drop Wire Clamp Aluminum 23-8885 Senior Industries (MSI) 6-Pair Drop Wire Clamp Stainless SI-0956 Allied Bolt, Inc. 6-Pair Drop Wire Clamp Stainless 909 Page 3 of 6

Preparation and Termination Procedure Cable Entry ADP S / ADP NMS aerial service wires are equipped with a rip cord to facilitate separation of the jacket from the insulated conductors. Superior Essex places the rip cord on the opposite side of the indent print. 1. Determine the length of jacket to be removed allowing an extra 3 to 4 inches to start the wire insulation removal and mark the wire at that length. 2. Using diagonal cutters, cut each side of the aerial service wire (the portion containing the fiberglass strength members). The cut should be 3 to 4 inches from the end to be terminated. Insure that the cut is sufficiently deep to cut through the fiberglass strength members. Do not be concerned if an underlying conductor is nicked because it will be removed prior to final installation (see step 7). Note: 5 snips may also be used. 3. Using the diagonal cutters, cut the jacket on the top and bottom to complete the jacket separation (mostly necessary on the 6-pair). 4. Secure the aerial service wire in both hands and remove the severed jacket section by pulling. Page 4 of 6

5. Separate the rip cord from the insulated conductors. The rip cord will be on opposite side of indent print. Ensure that the rip cord is not entangled with the insulated conductors. (Note that the 6-pair utilizes a core binder that should not be confused with the rip cord.) 6. Wrap rip cord around the diagonal cutters (or Needle-nose Pliers). Two or three wraps will be sufficient. Pull rip cord to slit desired length of jacket. A small starting notch will make starting the rip cord easier. Carefully pull the insulated conductors out of the jacket, maintaining the twist in conductors. 7. Remove jacket and cut the insulated conductors to required length for termination, ensuring removal of the first three to four inches (see step 1). Bonding and Grounding (ADP S Only) It is recommended that both ends of the ADP S aerial service wire (the distribution terminal end and the premises network interface end) are bonded and grounded using the procedures described below. Bonding and grounding are required to insure any interfering signals or voltages are shunted to ground. The drain wire may be utilized as a ground medium and is an easier method to bond and ground that will not create a bulky bond/ground point on the wire. This is the recommended method for bonding and grounding the ADP S aerial service wire since it requires no additional materials and takes less time to install. Page 5 of 6

Recommended Method 1. As the ADP S aerial service wire is prepared and terminated according to standard procedures, expose enough length of bare drain wire to reach the local grounding point within the distribution terminal or premises network interface. 2. Securely attach drain wire to desired ground point. Alternate Method Third party supplied mechanical shield bond connectors are available that do a good job of bonding to the metallic foil shield and then extending a ground lead to the local ground medium at each termination point. Procedural and technical support is readily available from each product s supplier. 1. After the desired lengths of conductors are exposed, prepare the metallic foil shield according to manufacturer s guidelines for shield bond connector/clamp installation. 2. Position the metallic foil shield according to the bond connector/clamp manufacturer s recommendation and attach connector/clamp to the metallic foil shield. 3. Securely attach ground wire to desired ground point. Third Party Manufacturer Description Part Number Shielded Aerial Service Wire Connector EM 2081 Electric Motion Company Shielded Aerial Service Wire Ground Kit EM 2082 Thomas & Betts ADSL Aerial Drop Bond Clasp Kit 18 ADSL 18 NOTE: This list is believed accurate at time of publication and is provided for convenience purposes only. Always check current compatibility. Manufacturers installation recommendations should be followed. Wire Termination - ADP S Only Wire termination must accommodate bonding of the metallic foil shield or use of the drain wire. 1. Extend the core wrap beyond the end of the metallic foil shield to provide dielectric protection between the shield and cable pairs. The exact length the core wrap extends beyond the metallic foil shield depends on the desired spacing between the shield connection and terminating point or device for the particular installation. 2. Extend the wire pairs beyond the end of the core wrap to allow for individual pair termination. The Aerial Service Wires are ready for final termination. Page 6 of 6