radiosurg One device for all surgical treatments!

Similar documents
Surgitron Dual Frequency 4.0 MHz Radiowave Technology

MICROWAVE DIATHERMY AND SURGICAL DIATHERMY DIATHERMICS

Electrosurgery Units (ESU s) and their variants

J-470 ELECTROSURGE. Radio Frequency Electrosurgery Unit. Operation Instructions

Instruction Manual. (English-English)

perioperativecpd.com The basics of diathermy

PINXEL. Micro Needle Rf & Fractional Rf

Electrosurgery Units (ESU s) and their variants. D. J. McMahon rev cewood

surtron.com SURTRON ELECTROSURGICAL units

Andy Falconer. Principles of surgical diathermy

ERBE ERBOTOM ICC 300. Instruction manual 08.00

ARC 200 HF SURGICAL GENERATOR SIMPLY SAFE

RAISING THE LEVEL OF PROTECTION IN YOUR ORS

SANO. Pinxel Introduction

User s Guide Aaron 940

INSTRUCTIONS ESG-400

ERBE. ERBOTOM ICC 80 / 50 Instruction manual 08.00

The use of sutures and ligatures is an integral part of surgical procedures. Being proficient in suturing and ligating will not only make your

MEDICAL ADVANCED TECHNOLOGY EMERGENCY REMOVAL UNIVERSAL EXTRACTION SET. for Intramedullary Nail System

What tests should be done?

USER S GUIDE. User s Guide Bovie IDS-400

ELEKTROTOM 610. Operating Instructions. Valid from version 1130

Bionic Fistula Needles. The gentle puncture

Leksell Neuro Generator

INTELECT SHORTWAVE DIATHERMY MOVING REHABILITATION FORWARD

Application Notes. Electrosurgical Analyzer Primer

Radio Frequency Electrosurgical System Specialist

HF- GENERATORS.

DIATERMO MB 122 AND MB 160 MONO-BIPOLAR W W

ELECTROSURGICAL GENERATOR USER S GUIDE

Electrosurgery. KLS Martin ME MB 2 SAFETY BY EASY USE

BOVIE SURGI-CENTER PRO. Electrosurgical Generator. User's Guide

ALSATOM SU MPC SU 50 MPC SU 100 MPC SU 140 MPC SU 140/D MPC SU 140/BD MPC

LIGHT THERAPY. Long wavelength. Low frequency. High frequency. Short wavelength. Part 2. General Sciences. application. application. wavelengths.

User s Guide Aaron 950

Meg1 (with Ligasmart)

DERM 941 DERM 942 High-Frequency Desiccators

OPERATING MANUAL ELECTROSURGICAL UNIT

RF leakage current in electrosurgical units: Influence of the layout in taking measurements

An Alternative Technique to Perform Surgeriesin Hospital by Surgical Diathermy

OPERATING MANUAL ELECTROSURGICAL UNIT

ARC 350 HF ELECTROSURGICAL GENERATOR SIMPLY SAFE

Novosyn Quick Your fast and efficient solution for a better quality of life

Frequently Asked Question on Isolated Power Supply(IPS)

FLUX CORE 90 WELDER ASSEMBLY & OPERATING INSTRUCTIONS

Basic Principles and Operation of Transformer

Eleven Pearls for Cosmetic Earlobe Repair

maxium electrosurgery unit with maxium Beamer

Low / Medium Power Electrosurgery Review 2002

Simple Interrupted Suture (using a tea towel)

Directions for Use. Veinlite A. TransLite, LLC.

M30 SPOT WELDER INSTRUCTION MANUAL 230V 1PH.

Physical Therapy. Methods in Physical Therapy. Non-electric heat therapy Therapeutique application of electric current

FOR BEAUTY PROFESSIONALS

Integra. Stainless Headed Compression Screw System SURGICAL TECHNIQUE

Aquamantys 3 Pump Generator User Guide. Revision F

NEW MINIMALLY-INVASIVE REJUVENATION METHODS. APTOS Catalogue

BM VET 80, 120, 140, 180 W

Simple Interrupted Suture (using a silicon skin pad)

Technique Guide. Modular Sternal Cable System. Flexibility and strength in sternal closure and repair.

Diamond-Gerjy Proktoskop

Crossfire Footswitch. User Guide

DIATERMO MB 122 AND MB 160 MONO-BIPOLAR W W

Radio System Strobe Wizard Plus Freemask

Questions or Concerns about a Permanent Access? Let s Talk!

Next-Generation Fractional CO2 Emerges. Annual Practice Survey Results Review of Autologous Treatments AAD 2011 Exhibitor Highlights THE

troubleshooting LEVEL 1 training

EXCELL NHP/T. A new step AheAd to the future ELECTROSURGICAL UNITS FOR MONOPOLAR AND BIPOLAR USE ISO ALSA IT ISO

Institute of Surgical Research A Module - Surgical Techniques

Site view of Naval Medical Center Portsmouth

PULSAR Generator Operator s Manual

Fundamentals of Pacing Therapy

Digital Compression Screw

Introduction to Medical Electronics Industry Test Analysis and Solution

TABLE OF CONTENT. 1. Introduction 1.1. Foreword Treatment objectives Work materials 2.1. Braces and loops

INTRODUCTION MIGATRONIC

RF Amplifiers and RF Heating for Medical Applications FTF-IND-F0690

Cerclage Passer. For minimally invasive application of cerclage cables.

Tubular Clamp-On Multifrequency Liquids & Gasses Processing Reactors

What language do you speak? English

Light has some interesting properties, many of which are used in medicine:

Dr.Rajaa CH.11. أ.م.د. رجاء سهيل جنم جامعة تكريت كلية طب االسنان

Micro Surgery Speciality Instrumentation

Chapter 28: The FotoFacial RF Pro Galaxy TM

AS SUPER 4 digital. Elektrischer Nadelstimulator / Electrical needle stimulator. Art.-Nr

MAC-AFRIC USER S MANUAL MODEL: D.C.INVERTER WELDER 160/200 AMP

DSL# EC 2009 Ethicon Endo-Surgery. All rights reserved PRODUCT CATALOG

White Paper: Technology and Clinical Overview of the Genii TouchSoft Coagulator monopolar probe

Application Note 175 Using the STMISOC Stimulus Isolator

MIS TECHNOLOGY GUIDE READ PRODUCT INSERT THOROUGHLY BEFORE USE

2018 ReachMD Page 1 of 9

We a r i n g m ag n i f y i n g loupes is b e c o m i n g standard

SPARK OF LIFE. How does your body react to electricity?

QUICK SETUP GUIDE SECULIFE ESPRO

Materials Cow eye, dissecting pan, dissecting kit, safety glasses, lab apron, and gloves

Standard Grade Physics Health Physics Ink Exercise G1

Acclaimed CO 2 Laser Authority Compares Delivery Systems

The University of New South Wales. School of Electrical Engineering and Telecommunications. High Voltage Systems ELEC9712. Appendix Partial Discharge

Heritage Oral Surgery and Implant Centers R. Dean Lang, D.D.S. Payam Samouhi, D.D.S, M.D. apc Don Kim, D.D.S, M.D. apc

Electrosurgery. KLS Martin ME 102. The compact Electrosurgical Unit with high Capacity

Transcription:

radiosurg 2200 One device for all surgical treatments! "We have not invented radio surgery but for its application we have set new standards." www.meyer-haake.com

Radio surgery for all medical fields instead of a scalpel! Removal of a rhinophyma The radiosurg 2200 is applicable for Child and neonatal surgery Dentistry Dermatology ENT surgery Esthetic-plastic surgery General surgery Gynecology Neurology Ophthalmology Oral and maxillofacial surgery Orthopedics Pediatrics Phlebology Plastic-esthetic surgery Podology Proctology Urology Vascular surgery and so on Advantages of correctly applied radio surgery Clear and open operation area No delayed wound healing Relaxed working without pressure Sterile area of operation No interfering bleeding Preservation of tissue tautness Conisation at the portio uteri with the BIO- CONE electrode Radio surgery can also be used successfully in the dental field. 2

FAQs What you always wanted to know 1. What is radio surgery? Radio surgery is the use of high frequency energy for cutting, cutting with simultaneous coagulation and coagulation on the human (or animal) body. 2. What is radio frequency? Radio frequency is an electric currency which is produced by the radio SURG 2200 with a frequency of 2.2 MHz (2 200 000 cycles per second). This energy of 2.2 million cycles/sec. is concentrated at the tip of the electrode. As soon as the tissue is touched, the cell vaporizes. This is because the fluid of the cell expands, the cell explodes and vaporizes. The effect of cutting or coagulation occurs quicker with units working within the megahertz range and, therefore, does not thermically damage the surrounding area. The electrode is a conductor for the high frequency power only and does not become hot. This can be demonstrated very well with an inflated balloon, which will not explode when touched with the activated electrode, as the heat develops only within the tissue when high frequency waves are used. 3. What are the advantages of megahertz units compared to kilohertz units? 3.1 Fewer sparks no burns With high frequency units it is possible to use smaller inductors electronic components which can store electricity in the generator, which results in smaller voltage peaks. The risk of light arcs, which can develop a heat of more than 1000 C, is dramatically reduced. Therefore, burning, necrosis and infections do not occur. Removal of a gynecomastia before after Removal of hypopigmentation with disc electrode 3.2 Voltage regulation Histo-pathological examination of a specimen The voltage of the radiosurg 2200 is regulated and is, therefore, constant during application (discrepancies of only ± 2%). Due to constant voltage it is possible to accomplish an excellent, clean cut, which barely differs from an incision made with a scalpel and which can be examined histo-pathologically. 3.3 Minimal risk of an electric shock Condensers (accumulator for electric energy) are incorporated into all high frequency units in order to prevent patients from the danger of continuous current flowing through their body. These condensers can discharge during surgery which leads to a sudden muscle convulsion and a short and intense pain. Within megahertz units, smaller condensers can be used, so the discharging is not noticeable and side-effects such as muscle convulsion and sudden intense pain do not occur. 3

FAQs What you always wanted to know preoperative 3.4 Minimized electric circuit resistance Units that have a higher frequency reach a constant and smaller electric circuit resistance between area of work and neutral electrode, therefore, units with a higher frequency ensure a safer conduction of the high frequency waves. intraoperative 4. What type of surgical interventions can be made with a radio surgical unit? In principle, a radio surgical unit can substitute a scalpel. Since operations can be performed without tension, pressure or any movement of the tissue, it is suitable for any type of surgical intervention, especially when very fine incisions are required, and if minor or major bleeding is expected. The absolute sterility of cuts along the cutting line of the electrode is a major advantage of radio surgery, as this prevents germs from being transported which can happen when using a scalpel. postoperative Traumatic rupture of the septum orbitale in ferio 5. What is the purpose of the automatic switch-off? The built-in automatic switch-off in radiosurg 2200 "TPA" gives doctors treating snorers the certainty that the tissue will be dehydrated only insofar that no burning or necrosis can occur, as the unit switches off automatically when a certain resistance is reached. The tissue is tightened with electrodes which of course are re-usable. With this method the patient suffers from slight swallowing difficulties for a few days only. The same method can be applied, for example for tonsil reduction, turbinate, etc. circumcision 4

FAQs What you always wanted to know 6. What is a trigger exit? The units are standard equipped with a trigger exit enabling a smoke evacuation system to be adapted e. g. the smokestar from Meyer- Haake. Physicians, staff and patients can be protected from contamination through toxic and potentially infectious combustion products. A surgical mask is in this case not sufficient, as it only filters 30 % of the combustion products. Patients are also completely unprotected. 7. What is a potential equalizer? It is a connector for additional grounding while using several electrical devices in the operation theatre to prevent current leakage (law in many hospitals). 5

FAQs What you always wanted to know 8. Can scalpel incisions be compared to radio surgical incisions? Tests have clearly shown that surgeries carried out with the cutting current (fully filtered wave) and an output frequency in the megahertz range, have a superior healing, compared to surgeries performed with a scalpel. Of course provided that the correct wave, power intensity, electrode and the suitable equipment are chosen. 9. How can hand pieces and electrodes be sterilized? Hand pieces and re-usable electrodes can be autoclaved up to a temperature of 134 C/275 F (hot steam phase 20 minutes prione programme). It is recommendable to purchase at least a second set of hand pieces and electrodes to enable sterile equipment to be available at all times. Hand pieces, cables and electrodes should be regularly examined for wear and tear. Please read the recommendations and comments in the instructions for use. 10. Contraindications for radio surgery a) All surgical contraindications b) Cardiac pacemakers c) Flammable vapors and liquids 6

FAQs What you always wanted to know 11. What is RF-ReFacing? Firmer facial features and a smoother décolleté with radio wave energy! The energy reaches the dermis and causes a shortening of the structures that have become too long. With gentle heat production and stimulation of the fibroblasts in the deeper tissues, the reconstruction of collagen and elastin is initiated. Without stressing the epidermis the tissue is tightened in the depth without pain, injection or hospitalization. More information material concerning this innovative anti-aging-method is available on our website: www.rf-refacing.com 1 = Skin texture prior to the RF-ReFacing Treatment 2 = RF-ReFacing Treatment 3 = Regenerated skin texture Example of a RF-ReFacing anti-agingtreatment: The patient was enthusiastic about her appearance after 4 treatments. She looks years younger. 7

Three waveforms (currents) are available: 1 Cutting current (fully filtered wave) The cutting current is the finest current and provides the smoothest cut, which leads to the quickest healing process. With this current better results can be achieved than with a scalpel, and should be your choice of current for all fine cuts. As this wave develops the lowest lateral heat only a few layers of cells evaporate. This current will be chosen when minimal cell vaporization is desired. Excisions taken with this current can be examined histo-pathologically. 2 Cutting and coagulating current (fully rectified wave) The fully rectified current simultaneously cuts and coagulates without necrotizing the tissue. Since this current produces a slightly higher lateral heat than the fully filtered wave, more cell layers evaporate. Simultaneous to the clean cut, coagulation along the cutting line takes place. The coagulation is so fine and gentle that only a whitish layer of coagulum is visible. 8

Three waveforms (currents) are available: 3 Coagulation current (partially rectified wave) Monopolar/Bipolar This current is exclusively suited for hemostasis and has only a slight cutting ability. It is suitable for every kind of hemostasis: Direct (via electrode e. g. ball or thick needle) or Indirect (via clamps or forceps) or Bipolar (via bipolar forceps) The radiosurg 2200 offers 4 varieties of this current: Mono coagulation current: Permanent and pulse coagulation, adjustable coagulation degree Bipolar coagulation current: Permanent and pulse coagulation, adjustable coagulation degree The coagulation degree can be adjusted from 1 to 9 according to the situation. Heavy bleeding = higher coagulation degree; weaker bleeding = lower coagulation degree. Hemorrhaging can thus be prevented. The pulse coagulation revolutionizes hemostasis. During this process high power is applied for a limited time to the end of the bleeding vessel (adjustable from 0.05 to 0.45 seconds), causing an immediate protein clotting that "welds" the vessel. Unlike a vessel with a necrotic end, a "welded" one is not as likely to break open again. Additionally the radiosurg 2200 "TPA" offers an automatic switchoff for the use in ENT surgery and the bipolar setting 0 for bipolar preparation (e. g. via bipolar scissors). 9

Three waveforms (currents) are available: Fulguration current What does a fulguration current do, and why is it NOT installed in the radiosurg 2200? This current causes sparks without being in contact with tissue. It is installed for hemostasis in many units and is called "spray coagulation". As uncontrollable deep tissue destruction with necrotic margins occurs during this process, the fulguration wave is not installed in the radio SURG 2200. 1 2 3 1 Cutting current 2 Mono coagulation current 3 Bipolar coagulation current 10

radiosurg 2200 All units offer: Extensive range of accessories Adjustable coagulation degree Adjustable duration of coagulation Trigger exit for the adaption of a smoke evacuation system Memory function Monitored neutral electrode radiosurg 2200 "m" the monopolar version for private practices performing minor procedures only for dentistry economically priced frequency 2.2 MHz radiosurg 2200 "TP" the universal unit for private practices performing minor and major procedures for the OR in hospitals monopolar and bipolar features frequency 2.2 MHz radiosurg 2200 "TPA" the ENT version monopolar and bipolar features automatic switch-off for applications in the ENT field and bipolar mode 0 for bipolar preparations (e.g. with bipolar sicissors) for private practices performing minor and major procedures for the OR in hospitals frequency 2.2 MHz 11

Theory is no use without practice! A demo will convince you! radiosurg 2200 and smokestar The perfect match in the OR! Further information can be found in the smokestar brochure! "We have not invented radio surgery but for its application we have set new standards." 0044 radiosurg, RF-ReFacing, and EPIGLU are registered trademarks of the Meyer- Haake company. Utilisation and application requires prior approval or only in connection with the trademark protected products. HF-Frequency: 2.2 MHz High Frequency Power Max.: Cutting 100 watt Coagulation: 90 watt Bipolar Coagulation: 99 watt Measurements: L x W x D = 340 x 210 x 152 mm Mass / Weight: 60 Newton / 6.0 kg Colour of the Case: Whitish Aluminium RAL 9006 Manufacturer: Distributor: www.meyer-haake.com Meyer-Haake GmbH Telefon / Phone : +49(0)60 02-9 92 70-0 Medical Innovations Telefax / Telefax I : +49(0)60 02-9 92 70-22 Daimlerstr. 4 61239 Ober-Mörlen E-Mail: info@meyer-haake.com /export@meyer-haake.com Deutschland /Germany Internet: www.meyer-haake.com 05/ 14