Proposed changes on NZS 3404 specified part-turn method of tensioning high strength friction grip (HSFG) property class 8.8 bolts

Similar documents
S. Ramhormozian 1, G.C. Clifton 2 and H. Nguyen 3

ERECTION & CONSTRUCTION

Sliding shear capacities of the Asymmetric Friction Connection

Bolts and Set Screws Are they interchangeable?

Copyright. Michael Joseph Gilroy. May 1997

Instruction Manual for installing

Instruction Manual for installing

CH # 8. Two rectangular metal pieces, the aim is to join them

Bolt Tensioning. This document is a summary of...

SPECIFICATION FOR HIGH STRENGTH STRUCTURAL BOLTS

Note: Conditions where bending loads are imposed on the bolt e.g. non-parallel bolting surfaces, should be avoided.

Fasteners. Fastener. Chapter 18

Tightening of Structural Joints

Structural Bolting. Notice the Grade 5 has a much smaller head configuration and a shorter shank then the grade A325 structural bolt.

High Strength Weathering Steel Structural Bolting Assemblies PC 8.8 Hex. Cooper & Turner Ltd. Worldclass products for a.

Contents. Grade 2, 5, 8 Hex Bolts 4. Heavy Hex Head Structural Bolts 6. A325 and A490 Tension Control Bolts (TC) 13. Nuts 22.

Threaded Fasteners 2. Shigley s Mechanical Engineering Design

AN, MS, NAS Bolts. AN3 20 bolts are identified by a multi-part code:

1/2/2016. Lecture Slides. Screws, Fasteners, and the Design of Nonpermanent Joints. Reasons for Non-permanent Fasteners

Cast-in Ferrule Connections Load/Displacement Characteristics in Shear

ISO INTERNATIONAL STANDARD. Fasteners Torque/clamp force testing. Éléments de fixation Essais couple/tension. First edition

MSATCS302A. Detail bolts and welds for structural steelwork connections.

Bolt Material Types and Grades 1- Bolts made of carbon steel and alloy steel: 4.6, 4.8, 5.6, 5.8, 6.8, 8.8, 10.9 Nuts made of carbon steel and alloy

A training course delivered at a company s facility by Matrix Engineering, an approved provider of Bolt Science Training

ENGINEERING FUNDAMENTALS

TECH SHEET PEM - REF / TESTING CLINCH PERFORMANCE. SUBJECT: Testing clinch performance of self-clinching fasteners.

AN, MS, NAS Bolts. AN3 20 bolts are identified by a multi-part code:

Failure of Engineering Materials & Structures. Code 34. Bolted Joint s Relaxation Behavior: A FEA Study. Muhammad Abid and Saad Hussain

Bolted Joint Design. Mechanical Properties of Steel Fasteners in Service

USER MANUAL Nord-Lock X-series washers

Procedure for Wrench Calibration and Snug Tightening

Comparative Evaluation of Resistance Made Simple Shear Connection with Bolts and With Welding

A training course delivered at a company s facility by Matrix Engineering, an approved provider of Bolt Science Training

Proposal for new standard. Determination of interface friction between painted parts. Orientation. p. 1 (15) Draft1, Revised

UNIVERSITY OF THESSALY

Dowel connections in laminated strand lumber

Tex-452-A, Rotational Capacity Testing of Fasteners Using a Tension Measuring Device

CIRRUS AIRPLANE MAINTENANCE MANUAL

Guidelines for use of High Strength Friction Grip (HSFG) bolts on bridges on Indian Railways. Ordinary Bolt action 1: Bearing of bolt/ plate

Finite Element Modeling of Early Stage Self-loosening of Bolted Joints Haoliang Xu 1, a, Lihua Yang 1, b,, Lie Yu 1,2, c

In normal joints, the clamping force should equal the working load. In gasketed joints, it should be sufficient to create a seal.

STUDY AND ANALYSIS OF ANGULAR TORQUING OF ENGINE CYLINDER-HEAD BOLTS USING TORQUE-TO-YIELD BOLTS: A CASE STUDY

Permanent fasteners: Riveted joints Welded joints Detachable joints: Threaded fasteners screws, bolts and nuts, studs. Cotter joints Knuckle joints

HEICO FASTENING SYSTEMS. Simple Fast Reliable HEICO-TEC TENSION NUT

Mechanical joints. Major diameter Mean diameter Minor diameter Pitch p chamfer. Root Crest. Thread angle 2a. Dr. Salah Gasim Ahmed YIC 1

Disclaimer. Socket Products Socket depth limits maximum torque. Torque figures are based on 80% of maximum torque for a given key size.

Hazlan Abdul Hamid* & Mohammad Iqbal Shah Harsad

Moment-Resisting Connections In Laminated Veneer Lumber (LVL) Frames

TORQUE DESIGN, ANALYSIS AND CHARACTERIZATION OF CRITICAL FASTENERS IN DIESEL ENGINES

FURTHER STATIC TENSION TESTS OF BOLTED JOINTS. A B S T RAe T

BOLTCALC Program. problems. User Guide. Software for the Analysis of Bolted Joints

THE GATE COACHAll Rights Reserved 28, Jia Sarai N.Delhi ,-9998

Double Shear Testing of Bolts

SteelConstruction.info The free encyclopedia for UK steel construction information

Welded connections Welded connections are basically the same design in AISI as in AISC. Minor differences are present and outlined below.

Procedure for Testing Direct Tension Indicators (DTI) Assemblies

TECH SHEET PEM - REF / AXIAL THREAD CLEARANCE. SUBJECT: Method for providing adequate axial thread clearance

ODOT ITB Group 4 Item 33 Qty. 1

Hydraulic Tensioner Assembly: Load Loss Factors and Target Stress Limits

Tool School - Rotary Draw Bending Tooling. An Engineer s Guide to Bending Tubes

HEICO FASTENING SYSTEMS. Elastic Durable Secure HEICO-TEC REACTION NUT

Ductility of large-scale dowelled CLT connections under monotonic and cyclic loading

GB/Z Translated English of Chinese Standard: GB/Z

What happens to bolt tension in large joints?, Fasteners, Vol. 20, No. 3, 1965, Publication No. 286

INSTALLATION CHARACTERISTICS OF ASTM F1852 TWIST-OFF TYPE TENSION CONTROL STRUCTURAL BOLT/NUT/WASHER ASSEMBLIES

TECH SHEET PEM - REF / THREAD GALLING. SUBJECT: Root causes and guidelines to promote optimized fastener performance TECH SHEET

Two basic types of single

Instruction Manual for Installing HIGH-STRENGTH BOLTS

712 - STRUCTURAL STEEL CONSTRUCTION SECTION 712 STRUCTURAL STEEL CONSTRUCTION

Instructions for Prepping an Opening for SOSS Invisible Hinges

Practical Bolting and Gasketing for the Non Standard-Flanged Joint

Reinforcing Mesh Product Guide

Connection and Tension Member Design

A training course delivered to Engineers and Designers, at a company s premises, on the technical aspects of bolting.

MECH 344/M Machine Element Design

MECHANICAL ASSEMBLY John Wiley & Sons, Inc. M. P. Groover, Fundamentals of Modern Manufacturing 2/e

DTFACT 16 C IN PAVEMENT LIGHT FIXTURE TESTING AND ANALYSIS FINAL SUMMARY PRESENTATION

Design of structural connections for precast concrete buildings

A Tale of Tearouts: Web Supplement

Use of grooved clamping plate to increase strength of bolted moment connection on cold formed steel structures

Evaluation of In-Pavement Light Fixture Designs and Performance

Fasteners Table of Contents

1. Enumerate the most commonly used engineering materials and state some important properties and their engineering applications.

Structural Strength of Lapped Cold-Formed Steel Z-Shaped Purlin Connections with Vertical Slotted Holes

INSTALLATION PROCEDURE FOR TENSION CONTROL BOLTS

a) If a bolt is over-tightened, which will fail first the bolt, or the plastic?

GURANTEED TECHNICAL PARTICULARS OF BACK CLAMP FOR LT CROSS ARM

The predictive model for strength of inclined screws as shear connection in timber-concrete composite floor

Experimental Evaluation of Metal Composite Multi Bolt Radial Joint on Laminate Level, under uni Axial Tensile Loading

Reinforcing Mesh Product Guide

Testing of friction properties of fasteners

Load application in load cells - Tips for users

DEFORMATION CAPACITY OF large DIAMETER mgh STRENGTH BOLTS wrru WAISTED SHANK SUBJECTED TO AXIAL TENSIlE FORCE. (Received October 15, 2001)

TEST SERIES TO EVALUATE THE STRUCTURAL BEHAVIOUR OF ISOBOARD OVER RAFTER SYSTEM

AVOID INSECURE AND IMPROPER DIE FASTENING

Tightening Strategies for Bolted Joints Methods for Controlling and Analyzing Tightening

Development of a New-Generation Dowel and Screw Combination 2014 International Crosstie and Fastening System Symposium Urbana, IL, USA 3 June 2014

C-Clamps and Lifting Eyes (Eye Bolts)

Joint relaxation behaviour of gasketed bolted flanged pipe joint during assembly

Technical Manual. ETP-CLASSIC incl type R. Content

Transcription:

Proposed changes on NZS 3404 specified part-turn method of tensioning high strength friction grip (HSFG) property class 8.8 bolts S. Ramhormozian, G.C. Clifton Department of Civil Engineering, University of Auckland, Auckland. K. Cowie Steel Construction New Zealand, Auckland. 2016 NZSEE Conference ABSTRACT: High Strength Friction Grip (HSFG) property class 8.8 bolts are widely used in construction of steel structures. When fully tensioned, they enable rigid steel systems to be built without the need for site welding. In new developments, the design and behaviour of a generation of seismic energy dissipaters such as the Asymmetric Friction Connection (AFC) in the Sliding Hinge Joint (SHJ) are also dependent on the use of tensioned HSFG bolts, albeit to a lower level of tensioning. According to NZS 3404, HSFG property class 8.8 bolts, when installed in the Tension Bearing (TB) and/or Tension Friction (TF) bolt modes, must be tensioned based on the part-turn method of tightening or by using a direct-tension indication device. The partturn is identified by NZS 3404 with respect to the bolt length-to-diameter ratio and contact angle of the outer faces of the bolted parts. There is also a requirement identified by the most recent (2007) amendment to NZS 3404 regarding the minimum number of clear threads run out beneath the nut after tightening for fully tensioned HSFG bolts. This necessitates the existence of five, seven, or ten free threads at nut loaded face with respect to different bolt length-to-diameter ratios. These aspects have been the subject of experimental and analytical research and this paper presents the results of that research and proposed changes to the existing NZS 3404 recommendations as follows: Relaxing the minimum number of clear threads run out beneath the nut after tightening, to level that will deliver dependable performance but will make installation easier. Proposing a more precise definition for the bolt length when determining the required part-turn of the nut. Proposing a method of pre installation bolt inspection to increase the reliability of the installed bolt tension. 1 EXISTING NZS3404 RECOMMENDED PART TURN METHOD OF TIGHTENING According to NZS3404 (1997/2001/2007), the HSFG property class 8.8 bolts, when installed in the Tension Bearing (TB) and/or Tension Friction (TF) bolt modes, must be installed based on the partturn method of tightening or using a direct-tension indication device, to be fully tensioned i.e. reaching the minimum tensile strength (f uf ) of 830MPa. The TF bolt mode guarantees the joint to remain rigid under a defined level of loading in the operating condition and thus is a Serviceability Limit State (SLS) design, rather than design for Ultimate Limit State (ULS) loading. The TB bolt mode is for ULS design and makes the joint very likely to remain rigid under both SLS and ULS loading, however the joint may slip if overloaded e.g. by a severe earthquake. Those friction-type connections that are expected to undergo stable friction sliding e.g. the Asymmetric Friction Connection (AFC) in the Sliding Hinge Joint (SHJ), should be designed based on the TF mode and stable sliding shear capacity for the SLS and ULS respectively. The part-turn method of tightening first requires bolt tightening to snug tight, intended to bring all

plies into direct contact, followed by rotating the item to be turned (typically the nut) by a specific amount i.e. part-turn to ensure reaching the code specified minimum bolt tension. The minimum bolt tension at installation is specified in (NZS3404) and is approximately equivalent to the minimum proof load given in AS/NZS1252 (1996) (Table 1). Table 1. Minimum bolt tension for HSFG property class 8.8 bolts to (NZS3404)&(AS/NZS1252) Nominal bolt diameter (mm) Minimum bolt tension, (kn) M16 M20 M22 M24 M30 M36 95 145 180 210 335 490 The part-turn is identified by (NZS3404) with respect to the bolt length-to-diameter ratio and contact angle of the outer faces of the bolted parts. Table 2 shows the (NZS3404) specified part-turn to fully tension the HSFG property class 8.8 bolts. Additional notes to table 2 are given in (NZS3404). Table 2. Nut rotation from the snug-tight condition to fully tension HSFG property class 8.8 bolts to (NZS3404) Bolt length (Underside of head to end of bolt) Up to and including 4 diameters Over 4 diameters but not exceeding 8 diameters Over 8 diameters but not exceeding 12 diameters Disposition of outer face of bolted parts Both faces normal to bolt axis Once face normal to bolt axis and other sloped Both faces sloped 1/3 turn 1/2 turn 2/3 turn 1/2 turn 2/3 turn 5/6 turn 2/3 turn 5/6 turn 1 turn There are two other requirements identified by (NZS3404) for bolting. One is the projection of all types of bolt from the nut face to be one clear thread following tightening. This provision intends to ensure the full thread engagement over the total nut depth. This is accepted practice for snug-tight bolting categories, but is of critical importance for tensioned bolting categories (8.8/TF and 8.8/TB), where the achievement of the specified initial bolt tension necessitates the full thread engagement. The other requirement is the minimum number of clear threads run out beneath the nut after tightening for fully tensioned HSFG bolts. This requires the existence of five, seven, or ten free threads under the nut loaded face with respect to different bolt length-to-diameter ratios and is based on avoiding excessive plastic strain demand in threaded region of the grip length when the bolt is fully tensioned. 2 BOLT FRACTURE AND VARIABLE INSTALLED TENSION OBSERVED IN THE BOLT TIGHTENING RESEARCH Ramhormozian, Clifton et al. (2015) observed a larger than expected variability in the HSFG property class 8.8 installed bolt tension during the first round of the bolt tightening tests of the SHJAFC with and without Belleville Springs. They also observed a few unexpected bolt fractures, during tightening, at a measured tension far below the yielding point e.g. 50% of the bolt proof load. The following investigations were performed to identify the reason behind the underachievement of code specified installed bolt tension as well as unexpected bolt fractures (Ramhormozian, Clifton et al. 2015). 2

Undertaking the bolt tightening tests on the bolts purchased from two different New Zealand based specialist suppliers and continuously monitoring the bolt tension during the tightening by a specialist load cell. Using additional hardened washers under the head of the bolt for a few samples to show 8 threads in the grip length in compliance with minimum threads requirements of (NZS3404). Performing the tensile tests on three bolts to ascertain the mechanical properties of the bolt and comparing the bolt behaviour in direct tensile test and tightening test. Based on the following observations and comparisons, Ramhormozian, Clifton et al. (2015) discussed and concluded that the poor thread and finish quality was the main reason for the underachievement of the specified installed bolt tension and the bolt fracture. The material properties of the bolt steel were identified to be in excess of those specified by the bolting standard by the tensile tests. The bolts with rougher galvanized surface and/or more resistance against turning the nut before installation and/or no visible lubrication, showed much higher tendency to show poor behaviour during tightening. All of the bolts, that had been tightened up to their elastic range, were subject to the permanent elongation after untightening. The applied torque as well as nut turn for a given bolt tension were higher than expected. The bolt tension vs length curves were nonlinear while the bolts were being tightened in their elastic range. Necking was observed in all tensile tests showing a ductile behaviour. Additionally both modes of fracture i.e. in tightening and pure tensile tests were ductile, but different in appearance, suggesting a different mode of fracture. The abovementioned research and conclusions led to define and perform another research which is explained in section 3. 3 A RESEARCH TO INVESTIGATE THE EXISTING NZS3404 RECOMMENDED PART TURN METHOD OF TIGHTENING Ramhormozian, Clifton et al. (2015) performed a research to explore the practical and theoretical concerns about the current (NZS3404) recommended part-turn method of HSFG bolt tightening. A practical concern is that the joints grip lengths are quite variable in practice and, as a result, satisfying the minimum thread length requirement at the nut loaded face has been an issue reported frequently by the industry. The research investigated whether the minimum number of clear threads run out beneath the nut after tightening introduced during the 2007 amendment of NZS 3404 could be relaxed to remove the difficulties that erectors have been faced with in order to comply with the current minimum thread provisions of (NZS3404). It is worth noting that the minimum thread requirements were introduced in the amendment in (NZS3404) in 2007 to overcome examples of bolt fracture reported at that time in bolts which had been correctly installed, which were attributed to too short a threaded length within the grip length. However, based on (Ramhormozian, Clifton et al. 2015), it is more likely that bolt fracture was generated by the poor quality of the thread finish, bolt surface cleanliness, and lack of lubrication supplied and not the bolt threaded length within the grip length. As for the theoretical concern, the applied part-turn imposes a longitudinal strain significantly beyond yield on the loaded parts of the bolt to reach the required bolt tension. The free unloaded bolt threaded portion beyond the nut is the only part of the bolt which does not contribute in accommodating this applied strain. Hence, a more precise criterion should exclude this part to identify the required partturn, otherwise the applied part-turn can lead to excessive tightening of long bolts with short grip lengths. This is discussed in section 4. 3

Ramhormozian, Clifton et al. (2015) performed 12 tensile tests on M20 and M24 bolts purchased from two New Zealand based specialist bolt suppliers, to validate the bolt material quality according to (NZS3404) and (AS/NZS4291). All of the bolts behaved as expected in the tensile tests according to the inspection certificates provided by each bolt supplier, and the fracture surfaces of the tensile tested bolts confirmed the ductile fracture of the bolts in tensile tests. The researchers developed a bolt tightening test setup to allow the existence of 1 to 8 free threads at the loaded face of the nut and tested 84 HSFG Property class 8.8 M20 and M24 bolts purchased from two different specialist bolt manufacturers. They concluded each test by tightening the bolts to fracture, to investigate the required turn of the nut after snug tight condition to fracture the bolt. They also undertook a pre-installation check and preparation for all of the bolts before the tightening tests in accordance with the recommendations of (Ramhormozian, Clifton et al. 2015). They used specialist donut load cells to continuously monitor the bolt tension during tightening. Figure 1 shows two typical bolt tension-time graphs of the tightening tests with their associated data analysis tables. Snug-tight Part-turn No DATA ANALYSIS OUTCOMES Unit Values 1 Snug tight tension kn 121 2 Proof load kn 145 3 Bolt tension after applying the part turn kn 201 4 Bolt tension drop after tightening % 3 5 Applied turns (After snug tight) Turn 0.25 6 Applied rotation (After snug tight) Degree 90 7 Required turn recommended by NZS 3404 Turn N/A 8 Required rotation recommended by NZS 3404 Degree N/A 9 The turn required after snug tight to just reach the proof load Turn 0.08 10 The rotation required after snug tight to just reach the proof load Degree 27 11 The turn to fracture after snug tight Turn 1.3125 12 The rotation to fracture after snug tight Degree 472.5 13 Nut turning condition before tightening test Free 14 Nut turning condition during untightening Free Figure 1 - Typical bolt tension vs time graphs of the tightening tests (left) and associated data analysis tables (right) (Ramhormozian, Clifton et al. 2015) All of the tested bolts were also fracture tested i.e. tightened up to the snug tight condition and then bolt nut was turned to tighten the bolt until the bolt was fractured to record the amount of the nut turn from the snug tight condition up to the point of fracture. The results of the research are being used to support proposed changes on NZS 3404 specified partturn method of tensioning (HSFG) property class 8.8 bolts. These results are presented in (Ramhormozian, Clifton et al. 2015; Ramhormozian, Clifton et al. 2015). The proposed changes are presented in section 5 of this paper. 4 CALCULATING THE REQUIRED NUT TURN BASED ON A BOLT LENGTH DEFINITION TO REACH THE BOLT PROOF LOAD Ramhormozian, Clifton et al. (2014) proposed a set of equations to calculate the required turn of the nut to tighten the bolts with Belleville springs up to an arbitrary amount of the bolt preload. The equations were modified for the case with no Belleville spring and re-presented in (Ramhormozian, Clifton et al. 2015) to calculate the required turn of the nut to tighten the bolt up to a certain amount of the elastic bolt preload. A detailed analytical model is proposed by Ramhormozian, Clifton et al. (In prep.) taking the flexibility of the joint plies, the bolt head, shank, thread, engaged thread with nut, nut, and hardened washer into account to calculate the required nut rotation to tighten the bolt. This analytical model has been applied in this paper to the whole bolt length ranges of HSFG property class 8.8 M20 bolts included in the table 2.2 of (AS/NZS1252). This includes the bolt length from 45mm to 150mm. It is worth noting that the (AS/NZS1252) defines the bolt length as the distance from underside of the head to end of bolt. Tables 3 and 4 show the characteristics of the bolts, nuts, and hardened washers calculated based on the information given in (AS/NZS1252). 4

Table 3. Characteristics of the bolts according to (AS/NZS1252) used to apply the analytical model Bolt overal length (mm) Shank length (mm) Theoretically possible ply thickness (mm) Maximum possible Thread length (mm) Nom. Min. Max. Average Ls (min) Lg (max) Average Max. ( NZS3404 provisions ) Min. ( Shank ) number of free threads 45 43.75 46.25 45 10 17.5 13.75 31.25 18.6 13.75 3.48 50 48.75 51.25 50 10 17.5 13.75 36.25 23.6 13.75 5.48 55 53.5 56.5 55 10 17.5 13.75 41.25 28.6 13.75 7.48 60 58.5 61.5 60 10 17.5 13.75 46.25 33.6 13.75 9.48 65 63.5 66.5 65 11.5 19 15.25 49.75 38.6 15.25 10.88 70 68.5 71.5 70 16.5 24 20.25 49.75 43.6 20.25 10.88 75 73.5 76.5 75 21.5 29 25.25 49.75 48.6 25.25 10.88 80 78.5 81.5 80 26.5 34 30.25 49.75 53.6 30.25 10.88 85 83.25 86.75 85 31.5 39 35.25 49.75 58.6 35.25 10.88 90 88.25 91.75 90 36.5 44 40.25 49.75 63.6 40.25 10.88 95 93.25 96.75 95 41.5 49 45.25 49.75 68.6 45.25 10.88 100 98.25 101.75 100 46.5 54 50.25 49.75 73.6 50.25 10.88 110 108.25 111.75 110 56.5 64 60.25 49.75 83.6 60.25 10.88 120 118.25 121.75 120 66.5 74 70.25 49.75 93.6 70.25 10.88 130 128 132 130 70.5 78 74.25 55.75 103.6 74.25 13.28 140 138 142 140 80.5 88 84.25 55.75 113.6 84.25 13.28 150 148 152 150 90.5 98 94.25 55.75 123.6 94.25 13.28 Table 4. Characteristics of the bolts, nut, washer according to (AS/NZS1252) used to apply the analytical model Nut height (mm) Head height (mm) Min. Max. Average Min. Max. Average 19.40 20.70 20.05 11.60 13.40 12.50 Nut Max OD (mm) Shank diameter (mm) Min. Max. Average Min. Max. Average 37.29 39.26 38.28 19.16 20.84 20.00 Nut Min OD (mm) Washer ID (mm) Min. Max. Average Min. Max. Average 33.00 34.00 33.50 22.00 22.52 22.26 Stress area of thread (mm^2) Nut OD (Average) (mm) 245.00 35.89 Washer thickness (mm) Washer OD (mm) Min. Max. Average Min. Max. Average 3.10 4.60 3.85 40.40 42.00 41.20 Bolt proof load (kn) Shank area (mm^2) Thread diameter (mm) Pitch (mm) 145.00 314.16 17.66 2.50 The theoretical nut rotation required to take the M20 bolts just to the proof load i.e. 145kN from the point at which the bolt s head underside, plies, hardened washer, and bolt s nut underside are all initially perfectly in contact with zero tension in the bolt, has been calculated for all bolt length ranges and is shown in Figure 2. This calculation was performed for each bolt length, and over the whole possible (ply+washer) thickness ranges being able to be clamped by the bolt. The lower (ply+washer) thickness is considered as (shank length+one pitch), and the upper (ply+washer) thickness is considered where there is only one free thread beyond the nut according to (NZS3404) recommendation. The graph shows the required nut turn versus the length from head s underside to the nut s underside. Although the part-turn of the nut to be applied after snug-tight condition is different from the required turn which is demonstrated in Figure 2, it still shows the behaviour of the bolts with different lengths, shank to thread lengths ratio, and grip lengths in tightening. This helps to present a robust definition for the bolt length while specifying the part-turn. 5

Required turn of the nut (Degree) 55 HSFG M20 bolt length ranges of AS_NZS 1252: Required turn of the nut to reach the bolt proof load 50 45 40 35 30 25 20 15 10 15 35 55 75 95 115 Underside of the head to underside of the nut (mm) Figure 2 - Nut rotation required to reach the HSFG property class 8.8 bolts just to the proof load It can be concluded from Figure 2 that the required nut rotation is mainly related to and governed by the (ply+washer) thickness and not the bolt length or shank to thread lengths ratio. For a given (ply+washer) thickness to be clamped by two bolts with different lengths and shank to thread lengths ratios, the bolt with longer shank requires slightly less rotation, as it is stiffer. However, this difference is very small, being less than 2 degree. On the other hand, for a given bolt length, the nut rotation required to reach the bolt to the proof load, when for example, the bolt is used to clamp the minimum and maximum possible (ply+washer) thicknesses, are considerably different. According to (Kulak and Eng 2005), the laboratory based specified part-turn is identified based on the bolt length, however it is expected that the end of the bolt will either be flush with the outer face of the nut or project slightly beyond it, and if the combination of bolt length and grip is such that there is a large "stick through", then it is advisable to treat the bolt length as the distance from the underside of the bolt head to the outer face of the nut for the purpose of selecting the proper turn to be applied. The specified part-turn values identified in (NZS3404) are the same as the Canadian code (Kulak and Eng 2005). In conclusion, an appropriate definition for the bolt length to determine the part-turn should be (ply+washer) thickness (or grip length) plus/minus a constant value. This constant value may be the nut thickness, resulting in defining the bolt length as underside of bolt head to outer face of nut, with the purpose of extracting the part-turn value from Table 2. This definition is supported by the analytical and experimental results. 5 RECOMMENDATIONS FOR NEW ZEALAND BOLTING PRACTICE AND PROPOSED CHANGES TO NZS 3404 It is highly recommended to follow all of the recommendations presented in Ramhormozian, Clifton et al. (2015) and Ramhormozian, Clifton et al. (2015) in New Zealand bolting practice to assure the reliability of the bolted connections. These include the recommendations on the bolt storage and lubrication conditions, bolt inspection and preparation prior to installation, and method of bolt tightening. The following recommendations have been proposed to be included in the next amendment of NZS 3404: Addition to clause 14.3.6.1.1: 45 50 55 60 65 70 75 80 85 90 95 100 110 120 130 140 150 Nuts shall run freely when part of a bolt/nut assembly. This shall be checked by running the nut along the bolts threads by hand the full length of the thread before being used in a connection. 6

Plastic elongation accommodated by the free threaded region under the loaded facec of the nut from the proof load to the point of fracture (mm) Only bolt/nut assemblies that pass this test shall be used. Once a bolt/nut assembly has been so tested neither component shall be substituted. Change on clause 14.3.6.1.2: (c) For tensioned bolts to either 15.2.5.2 or 15.2.5.3, at least two clear threads run out shall be clear beneath the nut after tightening. Change on table 15.2.5.2: The bolt length is defined as underside of bolt head to outer face of nut. It is recommended to consider the current NZS 3404 recommended minimum number of threads only for the bolts in Moment Resisting Endplate (MRE) connections. MRE connections can increase the plastic tension strain on the bolt if the system including the connection is put into inelastic action through severe earthquake actions. If the governing mode of endplate failure is mode 1, there will not be expected separation at the bolt line but there will be an amount of rotation of the bolt head or nut depending on which is in contact with the deforming plate. If the governing mode of failure is mode 2, there is expected separation at the bolt line i.e. additional plastic strain on the bolt. Fortunately, MRE connections involve large grip lengths, so meeting the current criteria for these is straightforward. Figure 3 shows the plastic elongation accommodated by the free threaded region under the loaded face of the nut from the proof load to the point of fracture. This is calculated and plotted for the three longest HSFG property class 8.8 M20 bolts i.e. 130, 140, and 150 mm based on the following simplified assumptions: 1. The strain associated with the proof load in HSFG G8.8 bolts is 0.003 i.e. 600MPa/205GPa. 2. The strain associated with the point of fracture in HSFG G8.8 bolts is 0.12 (Blendulf). 3. When the bolt reaches the proof load, the weakest part i.e. threaded part under the loaded face of the nut, yields while the shank, head, and nut engaged with thread remain elastic. 4. From the proof load, by increasing the distance between underside of the head and underside of the nut, the bolt tension does not increase and the displacement will be on a flat line i.e. assuming a perfect elasto-plastic behaviour for the bolt. 5. All of the additional strain mentioned in item 4 will be accommodated by the weakest yielded part mentioned in item 3. This is conservative as the other parts will also contribute in accommodating the required plastic elongation in reality. 6. A minimum number of 2 to 11 free threads are considered at the loaded face of the nut. 3.5 3 2.5 2 1.5 1 0.5 0 130 140 150 0 5 10 15 Number of free threads under the loaded face of the nut Figure 3 - plastic elongation accommodated by the free threaded region under the loaded face of the nut from the proof load to the point of fracture, for 130, 140, and 150 mm long HSFG property class 8.8 M20 bolts 7

The maximum of the calculated additional elongation among the three bolt lengths is 3.13mm achieved by existence of 11 free threads at loaded face of the nut. The maximum additional elongation for a shorter bolt e.g. 120mm, is 2.6mm when there is 9 free threads at loaded face of the nut. According to (Ramhormozian, Clifton et al. 2015) for the M20 bolts which had more than two threads at loaded face of the nut (what has been proposed by this paper) the minimum achieved post snug-tight turn to fracture was more than 300degree. The code specified part-turn associated with the bolt samples, based on the new proposed definition for the bolt length, is 1/3 turn. Hence, there is 300-120=180 degree of turn that the bolt could accommodate prior to fracture after installation. This may be ((180/360)*2.5)=1.25mm of additional elongation if a constant value for the pitch is assumed. Additionally by turning the nut the bolt is being shortened, so the situation is worse compared with directly stretching the bolt e.g. in MEP. The condition for fracture tested M24 bolts by Ramhormozian, Clifton et al. (2015) is slightly better as they could accommodate more turn to fracture, roughly associated with 2.5mm of additional elongation. Although by increasing the number of threads the turn to fracture increased, there is not a robust correlation between the number of free threads and turn to fracture based on the experimental results of (Ramhormozian, Clifton et al. 2015). Additionally, as is shown in Figure 4 there is a considerable difference between the bolt capacity to accommodate the additional plastic strain in torqued tension and direct tension. This relies in the torsion and tension interaction that decreases the bolt capacity to undergo plastic elongation compared with the direct tension. Figure 4 - load versus elongation relationship of A325 (equivalent to G8.8) bolts tested in torqued tension and direct tension. (Kulak, Fisher et al. 2001) Figure 4 shows the importance of the pre-installation free turn of nut check in preventing plastifying the bolt in torsion during tightening causing to decrease its capacity to accommodate additional plastic elongation in MRE connections. 6 ONGOING AND FUTURE RESEARCH PLAN The following research is being undertaken by the authors: An analytical discussion on the torque-tension interaction during HSFG bolt tightening to determine the torque limit to just yield the bolt material under a combination of torque and tension. An experimental HSFG bolt tightening research to determine the required torque to turn the nut up to a certain level of bolt tension, for the cases which the bolts are lubricated and are not lubricated, but all have passed the proposed free turn of nut check. An analytical and experimental research may be undertaken to determine how many threads are needed in the grip length of the MRE connections bolts to accommodate an extra 3mm or an extra 5mm considering an additional factor of safety of bolt extension. It is also worth noting that the grip lengths in bolts in MRE connections are typically relatively large so with the proposed new definition for bolt length, the accommodation of additional threads, i.e. the current provisions, should be readily implemented. 8

7 CONCLUSIONS This paper provided a review on the current NZS3404 recommended method of tightening the High Strength Friction Grip (HSFG) property class 8.8 bolts. A brief review is also presented on the research that showed some significant issues with the current method of HSFG property class 8.8 bolt tightening in practice. A research to investigate the existing NZS3404 recommended part turn method of tightening is reported followed by theoretically calculating the required nut rotation to tighten the HSFG property class 8.8 bolts with different lengths and shank to thread lengths ratio included in AS/NZS1252. The recommendations for bolting practice and proposed changes to NZS3404 are outlined followed by the potential further research in this field. 8 ACKNOLEDGEMENT This research was financially supported by the Steel Construction New Zealand (SCNZ) and Earthquake Commission Research Foundation (Project 14/U687 Sliding Hinge Joint Connection with BeSs ). The authors are grateful for these supports. The first author PhD studies are financially supported by a departmental scholarship through the support and kindness of the PhD supervisor, Associate Professor G. Charles Clifton. This support is much appreciated. The authors would also like to acknowledge the efforts and help of the undergraduate and postgraduate students as well as technical and laboratory staff at the Department of Civil and Environmental Engineering, the University of Auckland involved in this research in conducting experimental testing. REFERENCES AS/NZS1252 (1996). High-strength steel bolts with associated nuts and washers for structural engineering. Australia/New Zealand Standard. AS/NZS4291 (1995). Mechanical properties of fasteners Part 1: Bolts, screws and studs AS/NZS 4291.1:1995. Australia/New Zealand Standard. Blendulf, B. Pushing The Limits. EduPro US, Inc. Kulak, G. and P. Eng (2005). "High Strength Bolting." vol. First Edition, CISC ICCA: 1. Kulak, G. L., J. W. Fisher and J. H. Struik (2001). "Guide to Design Criteria for Bolted and Riveted Joints Second Edition." NZS3404 (1997/2001/2007). Steel structures standard, incorporating Amendments 1 and 2, Wellington [N.Z.]: Standards New Zealand. Ramhormozian, S., G. Clifton and G. MacRae (2014). The Asymmetric Friction Connection with Belleville springs in the Sliding Hinge Joint. NZSEE, Auckland, New Zealand. Ramhormozian, S., G. C. Clifton, K. Cowie and H. Nguyen (2015). Determination of the Required Part-turn of the Nut with Respect to the Number of Free Threads Uunder the Loaded Face of the Nut in Fully Tensioned High Strength Friction Grip Property Class 8.8 Bolts. Steel Construction New Zealand (SCNZ), University of Auckland (UoA). Ramhormozian, S., G. C. Clifton, G. A. Macrae and H.-H. Khoo (2015). The High Strength Friction Grip Property Class 8.8 Bolts: Variability of Installed Tension and Potential Resulting Effects on the Friction-type Connections Behaviour. New Zealand Society for Earthquake Engineering (NZSEE) Annual Technical Conference, New Dimensions in Earthquake Resilience. Rotorua, New Zealand Ramhormozian, S., G. C. Clifton, G. A. MacRae and H.-H. Khoo (In prep.). "Analytical Discussion on the Asymmetric Friction Connection Bolt Installation and Post-sliding Tension Loss with and without Belleville Springs." In prep. Ramhormozian, S., G. C. Clifton, H. Nguyen and K. Cowie (2015). Determination of the Required Part-turn of the Nut with Respect to the Number of Free Threads Uunder the Loaded Face of the Nut in Fully Tensioned High Strength Friction Grip Property Class 8.8 Bolts. Steel Innovations Auckland, New Zealand. 9