FSM4000 Electromagnetic Flowmeter. Measurement made easy. The all-purpose flowmeter for conductive fluids

Similar documents
FSM4000 Electromagnetic Flowmeter. The all-purpose flowmeter for conductive fluids

ABB MEASUREMENT & ANALYTICS DATA SHEET. HygienicMaster FEH630 Electromagnetic flowmeter

Electromagnetic Flowmeter FXE4000 (COPA-XE/MAG-XE)

JUMO flowtrans MAG S01

Flow Measurement SITRANS F M

www. otech.com.sg EFS801 ELECTROMAGNETIC FLOWMETER

Flow Measurement SITRANS F M. Flow sensor MAG /49. Overview

OPTIFLUX 5000 Technical Datasheet

SITRANS F flowmeters SITRANS F M. Flow sensor MAG /48 Siemens FI Overview

OPTIFLUX 5000 Technical Datasheet

Flow Measurement SITRANS F M

HygienicMaster FEH500 Electromagnetic Flowmeter. A first-class choice for all hygienic applications

ProcessMaster FEP500 Electromagnetic Flowmeter. The process industry's first choice. Maximum measuring accuracy Maximum measuring error: 0.

ProcessMaster FEP300 Electromagnetic Flowmeter. The process industry's first choice

CoriolisMaster FCB330, FCB350, FCH330, FCH350 Coriolis mass flowmeter

Flow Measurement SITRANS F M. Transmitter TRANSMAG 2 with sensor 911/E 4/101. Overview

ProcessMaster FEP300 Electromagnetic flowmeter. The process industry's first choice

Mass Flowmeter CoriolisMaster FCM2000

Mass Flowmeter CoriolisMaster FCM2000

JUMO flowtrans MAG H01

Electromagnetic Flow Transmitter

FLOMID FX Electromagnetic Flowmeter

ABB Measurement & Analytics. FSM4000 The electromagnetic flowmeter of choice For critical applications in a wide range of industries

SITRANS F flowmeters. SITRANS F System information MAGFLO electromagnetic flowmeters 4/9

ABB FCB330 FCH350 Mass Flowmeter datasheet

TIDALFLUX 2300 F Technical Datasheet

INSERTION paddle wheel flowmeter for continuous flow measurement

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters. 4/18 Siemens FI

Magnetic-inductive flow meter. PITe / UMF2. Technical Datasheet. Maintenance-free Nearly no pressure drop Robust design Easy installation and start-up

Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 H

OPTIFLUX 1000 Technical Datasheet

Ambient Conditions. Operating Conditions. Pressure

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

4/11. Overview. Easier service Transmitter replacement requires no programming. SENSORPROM automatically updates all settings after initialization.

CoriolisMaster FCB330, FCB350 Coriolis Mass Flowmeter. 4-wire compact device For flow measurement of liquids and gases

INLINE flowmeter for continuous flow measurement

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

INLINE flowmeter for continuous flow measurement

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters 4/11

Magnetic-Inductive flow Meter fmi

Electromagnetic flowmeters and switches DWM 1000/2000

Technical Information Proline Promag 10P

INLINE flowmeter for continuous flow measurement

Electro-Magnetic Flowmeters COPA-XE

BATCHFLUX and BATCHCONTROL

OPTIMASS 1000 Technical Datasheet

SITRANS F flowmeters. SITRANS F M System information MAGFLO electromagnetic flowmeters 4/11

ABB MEASUREMENT & ANALYTICS DATA SHEET. CoriolisMaster FCB400, FCH400 Coriolis mass flowmeter

Electromagnetic Flowmeter FSM4000

Electromagnetic Flow Measuring System Two-wire, loop-powered PROline promag 23 P

Digital inductive conductivity transmitter

WATERFLUX 3070 Technical Datasheet

KMS305W. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Wafer Flowmeters with S300 display

Digital flow ELEMENT transmitter for continuous flow measurement

Technical Information Smartec CLD18

KFS. Flap-type flow meter. Design and range of application

Technical Information Smartec CLD18

BATCHFLUX 5500 C Technical Datasheet

Type F-20-3A Sanitary Pressure Transmitter NEMA 4X with Integral Junction Box

FLOWave SAW-Flowmeter

ProcessMaster FEP610, HygienicMaster FEH610 Electromagnetic flowmeter

Magnetic Flowmeter Systems

RADAR TRANSMITTERS BLISSFLEX 1100 SELECTION GUIDE. The characters of the order code have been described below

Digital flow ELEMENT transmitter for continuous flow measurement

Proline Promag 10P. Technical Information. Electromagnetic Flow Measuring System Flow measurement of liquids in chemical or process applications

Electromagnetic Flowmeter FSM4000

Digital flowmeter for continuous flow measurement

IFC 010 Signal Converter

Abridged Specifications: 10DS3111E/A Sensor with 50SM1000 Transmitter

The transducer component converts the measured signal and displays the actual value.

Rosemount Specifications. Product Data Sheet , Rev BA February 2009 PERFORMANCE SPECIFICATIONS

Coriolis Massflowmeter

Digital conductivity transmitter

Digital flowmeter for continuous flow measurement

Proline Promag 55S. Technical Information

UFM 800 W, C Ultrasonic flowmeter for water and wastewater

Technical Information Smartec CLD18

Electromagnetic Flow Measuring System promag 33

Resistance thermometers for process technology

FXF2000 (COPA-XF) Electromagnetic Flowmeter. All in one -Flowmeter. With pulsed DC field excitation in a compact design

Design and applications

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Advanced instrumentation solutions crafted with highest precision

Rosemount 8700 Series. Magnetic Flowmeter Systems. Rosemount 8700 Series. Product Data Sheet , Rev NB Catalog

Digital flow transmitter for continuous flow measurement

In-Line Resistance Thermometers Model TR25

Electromagnetic Flow Measuring System promag 35

Pressure transmitter For sanitary applications Model SA-11

KMS502F. ManuFlo Page 1 MANU ELECTRONICS PTY LTD Flow Measurement Products. Electromagnetic Flanged Flowmeters FEATURES: (sizes: 25mm to 200mm)

SM-10. Features. Variable Area Flowmeter with Sight Glass for Small Flow Volumes. Description: Application: / Indication without power supply

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016

Magnetic Inductive Flowmeter

SITRANS F M MAGFLO Electromagnetic Flowmeters Explore the Siemens Solution. sitrans f

DMH. Magnetic Inductive Flowmeter. for Conductive Fluids

Electromagnetic Flowmeter Hygienic/Sanitary

Technical Information Memosens CLS82D

Coriolis Mass Flow Measuring System promass 40 E

8000A Series Compact Magnetic Flowtubes Wafer Body, Ceramic- or pfa-lined 1.6 to 150 mm (1/16 to 6 in) Line Sizes

Indumax CLS50/CLS50D. Technical Information

Transcription:

Conten ts Data Sheet D8S7U Rev. FSM Electromagnetic Flowmeter Measurement made easy The all-purpose flowmeter for conductive fluids Function Electromagnetic flowmeters can be used to accurately measure the flowrate of liquids, slurries, pastes and sludges with an electrical conductivity of at least μs/cm (opt. /. μs/cm). Applications The system is specially designed to measure liquids in the pulp & paper and food & beverage industries. It can be used to measure fast changing processes, two phase liquids, continuous and pulsating flows (piston pump application). Benefits Digital signal processing (DSP) and zero stability ensure long-term stability and accuracy in both flow directions. Enhanced diagnostic functions and monitoring of coil and electrode circuits as well as magnetic field for increased operational stability. Verification via fingerprint. Key features Pressure equipment designed acc. to PED Directive 97/ EC Meter size DN DN (/... ) Accuracy < ±.% of rate (> DN ) Fluid temperature - C (-... 66 F) (opt. 8 C [6 F]) Hygienic certification: A Liners, PFA, PTFE, ETFE, hard or soft rubber, ceramic carbide Standardized installation lengths for DIN, ASME B6. or JIS B-K flanges AC / DC supply power

Data Sheet Electromagnetic Flowmeter FSM Electromagnetic Flowmeter FSM D8S7U Contents Overview of flowmeter sensor and transmitter designs... General information.... Measuring accuracy.... Grounding.... Installation Requirements.... Flowmeter Sizes, Pressure Ratings, Flow Range... 7. Flowrate nomograph... 9 Model SEF.... Specifications.... Dimensions.... Ordering information... Model SE_.... Specifications.... Dimensions.... Adapter for variable process connections DN... (/... ").... Ordering information... 6 Mounting accessories.... Ordering information Wafer type Accessories (Table H)... 6 Transmitter... 6. Specifications... 6. Inputs/outputs... 7 6. Digital communication... 7 6. Electrical connections... 9 6. Connection examples for peripherals (incl. HART)... 6 6.6 Dimensions... 66 6.7 Ordering information... 67 6.8 Flowmeter sensor simulator - FXC Flowmeter sensor simulator, for transmitter types FXE-E, FXM-XM, FXF-DF, FES7-ES7, FSM-S, FET... 68 6.9 Installation set for " pipe installation in field-mount housing... 68

Electromagnetic Flowmeter FSM D8S7U Overview of flowmeter sensor and transmitter designs Housing Material Alu. Housing, Series Stainless Steel Housing, Series DN... (/... 6") DN... (/... / ) DN... (... ") DN... (/... /") ) ) DN... ( 8... ") G- DN... (/... ") G DN... (... ) G9 ) ) Fixed Flange Fixed Flange Wafer type Variable Connections Flowmeter sensor Model number SEF SEF SEW SE_* Measured value error.% of rate (> DN ) DN PN DN PN DN PN DN PN * Wafer type - 6 6 Flange DIN /EN 9-...... - - Flange ASME B6. / B6.7 JIS B-K Pipe connection DIN 8 Weld stubs DIN 8 Weld stubs DIN 6 / ISO 7 Weld stubs ISO 7 / SMS /... " / CL CL / CL CL/JIS / CL/JIS CL/JIS - - - (/... / ), 8 (, ) 6, ( /, ) - - (/... / ), 8 (, ) 6, ( /, ) - - (/... / ), 8 (, ) 6, ( /, ) - - (... / ), 8 (, ) 6, ( /, ) - - (/... ) 6, ( /, ) Tri-clamp DIN 676 / ASME BPE External threads ISO 8 / - - (/... ) 6 E DIN 999 /8" sanitary connectors - - (/.../ ) B Lining Hard/soft rubber, ceramic PEEK, Torlon (< DN ) carbide, PTFE, PFA, PFA (vacuum-tight) PFA (> DN ) ETFE, other Conductivity Electrodes Process Connection Material Degree of protection acc. to EN 69 Fluid temperature µs/cm (optional /. µs/cm) Stainless steel.7 (6 Ti),.9 (9 L), Hastelloy B-/C-, platinum-iridium, tantalum, titanium Steel, stainless steel - G8 6 6 6 6 6/ / S S S R R R Q / J Q / J Q / J P / X P / X P / X T/K T/K > DN : Stainless steel. (6 L) < DN :.7 (6 Ti), PVC, POM IP 6 / IP 67 / IP 68 IP 6 / IP 67 / IP 68 IP 6 / IP 67 / IP 68 -... / 8 C -... 66 F / 6 F -... C -... 66 F -... C -... 66 F -... C -... 66 F Approvals Hygienic and sterile requirements - CIP/SIP-enabled A, CIP/SIP-enabled Pressure Equipment Directive 97//EC Conformity assessment in accordance with category III, fluid group CRN (Canadian Reg. Number) On request Transmitter Model number S Supply power 8 V AC, V AC/DC Current output /... ma, /... ma Impulse output active ( V), optocoupler ( ma) Ext. zero return yes Ext. totalizer reset yes Forward/reverse flow metering yes Communication HART protocol, PROFIBUS PA, FOUNDATION Fieldbus Pipe empty detection std. yes, DN or higher and µs/cm Self-monitoring, extended diagnostic functions yes, expanded diagnostic functions / fingerprint only in connection with flowmeters SE, SEF and SEF for DN or higher On-site display/totalization yes Density correction yes, manual entry (totalize and display in mass units) Degree of protection acc. to EN 69 IP 6 / IP 67, NEMA X G Housing field-mount housing ) Weld stubs ) Tri-clamp ) Threaded pipe connection ) External threads

Electromagnetic Flowmeter FSM D8S7U Change from one to two columns General information. Measuring accuracy.. Reference conditionsper EN 9 Fluid temperature Ambient temperature C (68 F) ± K C (68 F) ± K Power supply Line voltage as per name plate U N ± % Installation conditions Upstream > x DN straight section Downstream > x DN straight section DN = Flowmeter sensor size Warm-up phase min.. Maximum measuring error Pulse output DN (/ ): ± % v. M., ±, Q maxdn DN,... DN (/6... / ): ± % v. M., ±, Q maxdn DN... DN (/... ): Q >, Q maxdn ±, % v. M. Q <, Q maxdn ±, Q maxdn Q maxdn = maximum flowrate for the flowmeter size m/s Analog output effects Same as pulse output plus ±.% of rate ±. ma 6, %, %, % Y, % a a = DN (/") b = DN,... (/6)... /") c = DN... (/... "), % b, %, % c 6 8 m/s 6,, 9,7 6,,8 ft/s X Fig. Y Accuracy ± of rate X Flow velocity v G6-. Grounding The grounding of the flowmeter sensor is essential for both safety reasons, and to ensure trouble-free operation of the electromagnetic flowmeter. The ground screws on the flowmeter sensor are to be brought to ground potential. For technical reasons, this potential should be identical to the potential of the metering fluid, if possible. For plastic or insulated lined pipelines, the fluid is grounded by installing ground plates. When there are stray potentials present in the pipeline, we recommend installing a ground plate on both ends of the flowmeter sensor. To comply with the EMC and Low Voltage Directives, the connection box/ transmitter must be grounded in addition to the meter tube of the flowmeter sensor.. Installation Requirements The device measures the flowrate in both directions. Forward flow is the factory setting, as shown in Fig.. Fig. The following items must be observed:.. Electrode axis Electrode axis () as level as possible or rotated max.. Fig. max. G99 G

Electromagnetic Flowmeter FSM.. In- and outlet pipe sections The metering principle is independent of the flow profile as long as standing eddies do not extend into the metering section, such as may occur after double elbows (), in the event of tangential inflow, or where half-open gate valves are located upstream of the flowmeter sensor. In such cases, measures must be put in place to normalize the flow profile. Do not install fittings, manifolds, valves, etc., directly in front of the flowmeter sensor (). Butterfly valves must be installed so that the valve plate does not extend into the flowmeter sensor. Valves or other turn-off components should be installed in the outlet pipe section (). Experience has shown that, in most installations, straight inlet sections x DN long and straight outlet sections x DN long are sufficient (DN = nominal diameter of the sensor Fig. ). For test stands, the reference conditions of x DN straight inlet and x DN straight outlet must be provided, in accordance with EN 9 / ISO 9. Fig... Vertical connections xdn xdn G98 Vertical installation for measuring abrasive fluids, preferably with flow in upward direction... Free inlet or outlet D8S7U For a free outflow, do not install flowmeter at the highest point in the pipeline, since measuring tube may empty, creating bubbles (). For free inflow/outflow, provide an invert, to ensure that the pipeline is always full (). Fig. 7..6 Strongly contaminated fluids G986 For strongly contaminated fluids, a bypass connection according to the figure is recommended so that operation of the system can continue to run without interruption the during the mechanical cleaning. Fig. 8..7 Installation in the vicinity of pumps G987 For flowmeter sensors that are installed near pumps or other vibration-causing fixtures, the use of mechanical vibration control components is mandatory. Fig... Horizontal connections The measuring tube must always be full. Provide for a slight incline of the connection for degassing. G98 Fig. 9 G988 Fig. 6 G98

Electromagnetic Flowmeter FSM D8S7U..8 Installing the high temperature design The high temperature design allows for complete thermal insulation of the sensor. The pipeline and sensor must be insulated after installing the unit according to the following illustration. Nomograph for pressure drop determinations For adaptor with / = 8 Fig. Insulation G976..9 Installation in pipelines with larger nominal diameter Determine the resulting pressure loss when using reduction pieces ():. Calculate the diameter ratio d/d.. Determine the flow velocity based on the flow range nomograph (Fig. ).. Read the pressure drop on the Y-axis in Fig.. D d 8 Fig. Fig. d Inside diameter of the flowmeter v Flow velocity [m/s] p Pressure loss [mbar] D Inside diameter of the pipeline G989 6

wei Electromagnetic Flowmeter FSM D8S7U Change from one to two columns. Flowmeter Sizes, Pressure Ratings, Flow Range Meter size DN Standard pressure rating PN Min. flow velocity measuring range. m/s Max. flow velocity measuring range m/s. / /6 /..6. l/min l/min l/min.79.9.6.6. l/min l/min l/min.8.7.9 6 / / /.. l/min l/min l/min.9.. 8 l/min l/min l/min.6.. 8 /6 /8 / /... 7. l/min l/min l/min l/min..6.. l/min l/min l/min l/min 7.9 6 / / l/min l/min l/min.6. 7.9 6 l/min l/min l/min 6 9 6 8 / 6 9 m /h m /h m /h 6 6 8 m /h m /h m /h 6 8 79 6 6 6 6 m /h m /h m /h 9 6 m /h m /h m /h 7 89 6 8 /6 /6 /6 9 m /h m /h m /h 8 96 8 8 8 m /h m /h m /h 7 79 67 6 8 /6 /6 /6 6 m /h m /h m /h m /h 76 99 6 66 m /h m /h m /h m /h 9 98 67 99 6 7 8 8 8 66 9 m /h m /h m /h 96 96 96 8 m /h m /h m /h 8 88 79 9 6 m /h m /h 8 9 7 m /h m /h 669 8877 7

Electromagnetic Flowmeter FSM D8S7U Change from one to two columns Flange design and pressure rating Nominal diameter (/ / )... (/... ") ( /") ( /") (") 6 ( /") 8 (") (") (") (6") Flange ) Material PN PED /8" sanitary DIN ASME JIS DIN ASME JIS DIN ASME JIS DIN ASME JIS DIN ASME JIS DIN ASME JIS DIN ASME JIS DIN ASME JIS DIN ASME JIS ASME Stainless steel.7 (6 Ti) or POM, brass, PVC Stainless steel or steel Stainless steel or steel Stainless steel or steel Stainless steel or steel Stainless steel or steel Stainless steel or steel Stainless steel or steel Stainless steel or steel Stainless steel or steel bar, 6, bar ) CL, CL, CL6 ) bar bar CL, CL bar, 6, bar CL, CL, CL6 bar, 6, bar CL, CL, CL6 bar 6,, 6, bar CL, CL, CL6 bar, 6, bar CL, CL, CL6 bar 6,, 6, bar CL, CL, CL6 bar 6,, 6, bar CL, CL bar 6,, 6, bar CL, CL, CL6 bar CL SEP Sec. Para. Conformity assessment in accordance with category III, module B + D, fluid group Nominal diameter (8") (") (")... 6 (... ") 7... (8... ) Flange ) Material PN PED DIN ASME JIS DIN ASME JIS DIN ASME JIS DIN ASME JIS DIN ASME Stainless steel or steel Stainless steel or steel Stainless steel or steel Stainless steel or steel Stainless steel or steel, 6,,, 6, bar CL, CL, CL6 bar, 6,, bar CL, CL bar, 6,, bar CL, CL bar, 6, bar CL, CL bar, 6, bar CL ) Connecting dimensions for flange acc. to DIN / EN9- or ASME or JIS. ) PN6, PN only for nominal diameters DN and DN. ) CL6 only for nominal diameters DN and DN. Conformity assessment in accordance with category III, module B + D, fluid group Other meter sizes, pressure stages and temperature classes are available upon request. 8

Electromagnetic Flowmeter FSM. Flowrate nomograph The volume flowrate is a function of the flow velocity and the diameter of the flowmeter. The flowrate nomograph indicates the flowrate range for a specific flowmeter nominal diameter and which flowmeter nominal diameters are suitable for a specific flowrate. l/min m /h 8 6 8 6 8 6 8 6-8 6 8 6 8 6 8 6-8 6-8 6 - DN DN 8 DN 6 DN DN DN DN DN DN DN DN 8 DN 6 DN DN DN DN. DN l/s 8 6 8 6 8 6-8 6-8 6-8 6 l/min m /h 8 6 8 6 8 6 8 6 8 6 8 6,,6,8 DN DN 9 DN 8 DN 7 DN 6 DN DN DN DN DN DN DN DN DN 6 8 m/s D8S7U l/s 6 8 6 8 6 8 6 Fig. : Flowrate nomograph DN... DN (... ") G6 Example: Flowrate = 7 m /h (max. value = range end value). Sensor nominal diameters DN... DN 6 (/... /") are suitable for a flow velocity of.... m/s.,,6,8 6 8 m/s Fig. : Flowrate nomograph DN... DN (/... ") Example G 9

Electromagnetic Flowmeter FSM D8S7U Change from one to two columns Model SEF. Specifications Change from one to two columns Temperature graph Fig. : 6 G Fluid temperature as function of ambient temperature Ambient temperature C Fluid temperature C Standard flange (steel): Hard/soft rubber max. 9 / 6 C (9... F) Stainless steel flange Standard flange (steel): PTFE / PFA / ETFE max. C (66 F) 6 High temperature: Thick PTFE / PFA max. 8 C (6 F) Max. allowable cleaning temperature PTFE-, PFA-design CIP cleaning Liner Flowmeter sensor T max t max Min T amb. Steam cleaning PTFE, PFA C ( F) 6 C (77 F) Wet cleaning PTFE, PFA C (8 F) 6 C (77 F) If the ambient temperature is > C, then the difference must be subtracted from the max. cleaning temperature. T max - C. C = (T amb. - C) Weight See "Dimensions" Min. permissible pressure as a function of fluid temperature Lining Nominal diameter DN Hard rubber (/ ) Soft rubber ( ) PTFE 6 (/8 ) Thick PTFE hightemperature design 8 ( ) ( ) ( ) PFA (/ 8 ) P Operation mbar abs at T Operating < 9 C (9 F) < 6 C ( F) 7 67 7 < C (68 F) < C ( F) < C (66 F) < 8 C (6 F) < 8 C (6 F) < 8 C (6 F) < C (66 F) < 8 C (6 F) ETFE... (... ) < C (66 F) Ceramic carbide ( ) < 8 C (76 F) Flowmeter sensor material Parts Standard Others Lining Signal and ground electrode for - Hard rubber - Soft rubber - PTFE, PFA, ETFE Grounding plate Protection plate PTFE, PFA, hard rubber, soft rubber, ETFE Stainless steel.7 (6 Ti) Hastelloy C- (.6) Stainless steel.7 (6 Ti) Stainless steel.7 (6 Ti) Process connection material Ceramic carbide Hastelloy B- (.6), Hastelloy C- (.6), Titanium, tantalum, Platinumiridium, Stainless steel.9 (9 L) Stainless steel.7 (6 Ti) Hastelloy B- (.6), Titanium, tantalum, Platinumiridium, Stainless steel.9 (9 L) On request On request Parts Standard Others Flange DN... DN (/... / ) DN... DN (/... ) DN... DN (... ) Housing DN... (/... ) DN... DN (... ) Terminal box Meter tube Stainless steel ) Galvanized steel ) Painted steel ) Dual-shell casing, cast aluminum, painted, paint coat, 8 µm thick, RAL 9 Welded steel design, painted, paint coat, 8 µm thick, RAL 9 Al alloy, painted, 8 µm dick, frame: dark gray, RAL 7 Cover: light gray, RAL 9 Stainless steel. () Stainless steel ) cable gland used Polyamide The process connections are made of one of the materials listed below: ). (),.7,. (6L). (6L),. ().7 (6Ti), ASTM A8 F, ASTM A8 FL, ASTM A8 F6L, ASTM A8 F, ASTM A8 F6TI, ASTM A8 F6, Cr8Ni9, Cr8Ni, Cr7NiMo, Cr7NiMo, Cr8Ni9Ti, Cr8NiMoTi ).8,.6,.7,., ASTM A, QA, #, 6Mn

Electromagnetic Flowmeter FSM D8S7U Storage temperature -... 7 C (-... 8 F) PS [bar] PS [PSI] 9. Degree of protection acc. to EN 69 IP 6 / IP 67 IP 68 (option) 9 8 PN.. 6. Pipeline vibration according to EN 668--6 Transmitter - In the range of Hz, max. deflection. mm Flowmeter sensor - In the range of Hz, max. deflection. mm - In the range of Hz, max. acceleration g Designs The flanged flowmeters comply with the installation lengths specified in VDI / VDE 6, ISO 9 or according to DVGW (process sheet W, design WP; ISO 6 short). Material load Limits for allowable fluid temperature (TS) and allowable pressure (PS) are a function of the liner and flange material used (see the factory tag and name plate of the unit). Temperature limits Lining Flange material Hard rubber Soft rubber PTFE / ETFE Thick PTFE / PFA Ceramic carbide Steel Stainless steel Steel Stainless steel Steel Stainless steel Steel Stainless steel Steel Stainless steel Min. temper ature - C ( F) - C ( F) - C ( F) - C ( F) - C ( F) - C (- F) - C ( F) - C (- F) - C ( F) - C (- F) Max. temperature Standard High temperatur e 9 C (9 F) 9 C (9 F) 6 C ( F) 6 C ( F) C (66 F) C (66 F) C (66 F) C (66 F) 8 C (76 F) 8 C (76 F) 8 C (6 F) 8 C (6 F) - - 7 6 - - - PN 6 PN PN PN 6 PN 86 7 8 TS 9 9 66 Fig. 6: Stainless steel DIN flange up to DN 6 (") PS [bar] 9 8 7 6 - - - CL6 CL CL 86 7 8 TS 9 9 66 Fig. 7: Stainless steel ASME flange up to DN (6") (CL/); up to DN (") (CL); up to DN (8") (CL 6) PS [bar] 9 8 7 6 - - - PN PN 6 PN PN PN 6 PN 7 8 TS 9 9 Fig. 8: DIN flange SS to DN 6 ( ) 66. 87. 7. 8.. 9.. 7 [ C] 8 [ F] G89 PS [PSI] 9... 6.. 87. 7. 8.. 9.. 7 [ C] 8 [ F] G9 PS [PSI] 9... 6.. 87. 7. 8.. 9.. 7 [ C] 8 [ F] G88

Electromagnetic Flowmeter FSM D8S7U PS [bar] CL CL PS [psi] 797. 7. 6. 8. 7.. 6. 9. 7.. 7. - - 7 9 7 9 [ C] - 86 8 9 66 8 7 [ F] TS G8 Fig. 9: Steel ASME flange up to DN (6") (CL/); up to DN (") (CL) JIS K-B Flange Nominal size DN (¼ 6 ) (¼ 6 ) Material PN TS PS [bar] Stainless steel - +8 C (- +6 F) Steel - +8 C ( 66 F) PS [bar] 7 6 9 8 7 6 - - - 6 7 8 9 [ C] - - 68 86 8 76 9 [ F] DN 7 PN 6 DN 9 PN 6 DN 8 PN 6 DN PN 6 DN 9 PN DN 8 PN DN 7 PN DN PN TS PS [psi] 6.. 7.. 88. 7. 9... 6.. 87. G9 Fig. : Stainless steel DIN flange, DN 7... DN (8... ") PS [bar] 7 6 9 DN 7 PN 6 DN 9 PN 6 DN 8 PN 6 DN PN 6 PS [psi] 6.. 7.. 88. 7. 9... 8 DN 9 PN 6. DN 8 PN 7 DN 7 PN. 6 DN PN 87. - 6 7 8 9 [ C] TS - 68 86 8 76 9 [ F] G Fig. : DIN flange steel, DN 7... DN (8... )

Electromagnetic Flowmeter FSM D8S7U Change from one to two columns. Dimensions.. Model SEF Flange DN (/ ) 88 (.6) (.8) C D F E Fig. : Dimensions in mm (inch) Cable gland M x. or NPT Flange in acc. with DIN/EN 9- A L* Dimensions [mm] DN PN ) D L ) ) F ) C E ) A Approx. weight [kg]... 8 )... 9 8 6... 9 8 6... 9 8 6 6... 8 6 6... 8 6 7... 6 9 8... 6 9 9... 6 67 97 9 6... 8 78 8 8... 78 8... 6 7 7... 7... 6 8... 7 8 7 Tolerance L: + / - mm G977 Dimensions [inch] DN (inch) PN ) D L ) ) F ) C E ) A Approx. weight [lb]... 8 ) (/8... /6).... 7.87 6.6..96. (/8).... 7.87 6.6..96. (/)....7 7.87 6.6..96.. (/).... 7.87 6.6..96.. ().... 7.87 6.6..96.. ( /).... 7.87 6..6.. 7.6 ( /)....9 7.87 6..6.. 9.8 ()... 6. 7.87 6.7.8.7.. 6 ( /)... 7.8 7.87 7...9.9 8.66 8 ()... 7.87 7.87 7...9.9.7 ()... 6 8.66 9.8 7.87.8 6.77.9 7.8... 9. 9.8 7.87.8 6.77.9 6. ()... 6 9.8 9.8 8.7. 7.7.9.9....6 9.8 8.7. 7.7.9 9. Tolerance L: + / -.8 inch

Electromagnetic Flowmeter FSM D8S7U Flange in acc. with ASME B6. CL Dimensions [mm] CL ISO 9 ISO 9 Approx. weight [kg] DN Inch D L ) ) D L ) ) F ) C E ) A... 8 /8... /6 6) 89 96 8 6 /8 6) 89 96 8 6 / 89 96 8 6 6 / 98 8 8 6 6 8 8 6 7 / 8 6 9 9 / 7 6 6 9 9 6 67 97 9 6 / 78 9 78 8 8 9 78 8 7 9 7 9 / 8 8 8 / Tolerance L: + / - mm Dimensions [inch] CL CL ISO 9 ISO 9 Approx. weight [lb] DN Inch D L ) ) D L ) ) F ) C E ) A... 8 /8... /6 6). 7.87.78 7.87 6.6..96. /8 6). 7.87.78 7.87 6.6..96. /. 7.87.78 7.87 6.6..96.. /.86 7.87.6 7.87 6.6..96... 7.87.88 7.87 6.6..96.. /.6 7.87.8 7.87 6..6.. 9.8 / 7.87 6. 7.87 6..6.. 9.8 6. 7.87 6. 7.87 6.7.8.7.. 6 / 7. 7.87 7. 7.87 7...9.9 8.66 8 7. 7.87 8.7 7.87 7...9.9 7.8 9. 9.8 9.8 7.87.8 6.77.9.89 / 6.7 9.8. 9.8 8.7. 7.7.9.9 / 7.7 Tolerance L: + / -.8 inch ) Other pressure ratings available on request. ) If a grounding plate is installed (attached to one side of the flange), this increases dimension L as follows: DN... by mm.8 inch); DN by mm (.97 inch). ) If protection plates are installed (attached to both sides of the flange), this increases dimension L as follows: DN... by 6 mm (.6 inch; DN by mm (.9 inch). ) Depending on the device design, the dimensions change according to the following table. Device design Dimension E, F Standard temperature design High temperature version +7 mm (+ inch) ) Connection flange DN 6) Connection flange /" 7) Connecting dimensions in acc. with EN 9-. For DN 6, PN 6 in acc. with EN 9-, please order PN.

Electromagnetic Flowmeter FSM D8S7U.. Flange DN (6 ") 88 (.6) (.8) C D E F A L* G978 Fig. : Dimensions in mm (inch) Cable gland M x. or NPT Flange in acc. with DIN/EN 9- Dimensions [mm] DN PN ) D L ) ) F ) C E ) A Approx. weight [kg]... 6 8 7 6 9 66... 7 6 9 66 7 8 7 9 6 8 7 9 98 8 9 6 98 8 6 8 7 7 7 6 6 8 7 7 78 Tolerance L: DN... + / - mm, DN... + / - mm Dimensions [inch] DN PN ) D L ) ) F ) C E ) A Approx. weight [lb] (6)... 6..8..7 9. 6. 68.....8.8..7 9. 6. 8.7 (8).9.78. 6.69. 7.87 8.98 6.9.78. 6.69. 7.87 9.9 (). 7.7.8 7.8.8 9..7 6.9 7.7.8 7.8.8 9. 8.89 () 7. 9.68.9 8.98.9.7 8.7 6 8. 9.68.9 8.98.9.7 7.96 Tolerance L: DN... + / -.8 inch, DN... + / -.97 inch

Electromagnetic Flowmeter FSM D8S7U Flange in acc. with ASME B6. CL Dimensions [mm] CL ISO 9 ISO 9 Approx. weight [kg] DN Inch D L ) ) D L ) ) F ) C E ) A 6 8 8 7 6 9 66 / 8 8 8 7 8 / 7 7 98 8 68 / 8 8 7 7 / 8 Tolerance L: DN... + / - mm, DN... + / - mm Dimensions [inch] CL CL ISO 9 ISO 9 Approx. weight [lb] DN Inch D L ) ) D L ) ) F ) C E ) A 6..8..8..7 9. 6. 68. / 99. 8..78.78. 6.69. 7.87.8 /. 6. 7.7 7. 7.7.8 7.8.8 9. 9.9 / 7.8 9. 9.69. 9.69.9 8.98.9.7 7.8 / 6.8 Tolerance L: DN... + / -.8 inch, DN... + / -.97 inch ) Other pressure ratings available on request. ) If a grounding plate is installed (attached to one side of the flange), this increases dimension L by mm (.97 inch). ) If protection plates are installed (attached to both sides of the flange), this increases dimension L by mm (.9 inch). ) Depending on the device design, the dimensions change according to the following table. Device design Dimension E, F Standard temperature design High temperature version +7 mm (+ inch) 6

Electromagnetic Flowmeter FSM D8S7U.. Flange DN (6 ") C F E A Fig. : Cable gland M x. or NPT Flange in acc. with DIN/EN 9- L* Dimensions [mm] DN PN ) D L ) ) F C E A Approx. weight [kg] 6 6 6 6 67 7 9 7 6 8 6 67 7 9 7 7 67 6 7 7 88 6 7 6 7 7 8 6 78 78 6 6 69 8 6 8 78 6 6 69 6 7 89 9 9 69 7 8 6 9 9 9 69 7 8 8 9 6 8 6 9 6 88 9 7 9 69 67 6 7 9 69 67 88 6 69 79 688 6 6 69 79 88 Tolerance L: DN + / - mm, DN 6... + / - mm Dimensions [inch] DN (inch) PN ) D L ) ) F C E A Approx. weight [lb] () 9.88.6. 9.8..68 77.78 6.7.6. 9.8..68 8.6 (6)..6..8..7.7 6..6..8..7 8.8 () 6.8.9.87..76 6..9 6 8..9.87..76 6..7 6 ().7.7 7.87. 6.77 8.6 7. 6.7.7 7.87. 6.77 8.6 696.7 7 (8)..8 9.9.9 8.6. 7. 6.8.8 9.9.9 8.6. 96.67 8 () 9.96.9.6 7.9..8 9.8 6..9.6 7.9..8 7.9 9 (6).9 6.6. 9.88. 6. 8.98 6.9 6.6. 9.88. 6. 96.9 () 8..8.9.8.7 9.9 6.86 6 9..8.9.8.7 9.9 869.6 Tolerance L: DN + / -.97 inch, DN 6... + / -.9 inch D G979 7

Electromagnetic Flowmeter FSM D8S7U Flange up to DN 6 (") in acc. with ASME B6., flange DN 7... (8... ") in acc. with ASME B6.7, Series B CL Dimensions [mm] Installation length Approx. weight [kg] DN Inch D L ) ) F C E A 78 6 97 6 67 7 9 7 8 6 686 7 7 8 699 76 7 6 98 6 8 9 6 69 7 8 87 9 9 69 7 8 8 9 9 6 98 9 6 7 7 9 69 67 678 8 6 69 79 878 Tolerance L: DN... + / - mm, DN 6... + / - mm Dimensions [inch] CL Installation length Approx. weight [lb] DN Inch D L ) ) F C E A..6. 9.8..68 9. 6..6..8.9.7 96. 8. 7..87..76 6. 68.8 7...87..76 6.8 67. 6..98 7.87. 6.6 8.6 9.6 7 8.9.8 9.9.9 8.6. 767. 8 7.9.9.6 7.9..8 97.96 9 6.6 6.6. 9.88. 6. 9.8..8.9.8.7 9.9 9.76 Tolerance L: DN... + / -.97 inch, DN 6... + / -.9 inch ) Other pressure ratings available on request. ) If a grounding plate is installed (attached to one side of the flange), this increases dimension L as follows: DN... 6 um mm (.97 inch). ) If protection plates are installed (attached to both sides of the flange), this increases dimension L as follows: DN... 6 by mm (.9 inch). 8

Electromagnetic Flowmeter FSM D8S7U.. Flange DN... (/... 8"), high-pressure versions PN 6 and PN 88 (.6) (.8) C D F E Fig. : Dimensions in mm (inch) Cable gland M x. or NPT A L* G977 Flange in acc. with DIN 66 (PN 6) and DIN 67 (PN ) Dimensions [mm (inch)] / [kg (lb)] DN PN D L ) ) F ) C E ) A Approx. weight 6... 7 8 6 8 (.) (.6) (6.6) (.) (.96) (.) (7.6) 6... 7 8 6 (.) (.6) (6.6) (.) (.96) (.) (.) 6... 7 8 6 9 (6.69) (.) (6.) (.6) (.) (.) (6.6) 6 8 8 67 97 9 (7.9) (.) (6.7) (.8) (.7) (.) (8.66) 9 8 67 97 9 6 (7.68) (.) (6.7) (.8) (.7) (.) (.7) 6 6 78 8 6 (8.7) (.99) (7.) (.) (.9) (.9) (.7) 78 8 (8.66) (.99) (7.) (.) (.9) (.9) (6.) 8 6 78 8 (8.6) (.9) (7.) (.) (.9) (.9) (.9) 78 8 (9.6) (.9) (7.) (.) (.9) (.9) (.9) 6 7 7 (9.8) (.7) (7.87) (.8) (6.77) (.9) (9.) 6 7 6 (.) (.7) (7.87) (.8) (6.77) (.9) (79.7) Continued on next page 9

Electromagnetic Flowmeter FSM D8S7U Continued Dimensions [mm (inch)] DN PN D L ) ) F ) C E ) A 6 9 8 (.6) (7.7) (8.7) (.) (7.7) (.9) 8 (.) (7.7) (8.7) (.) (7.7) (.9) 6 7 6 9 66 (.8) (7.7) (.) (.7) (9.) (6.) 7 6 9 66 (.98) (7.7) (.) (.7) (9.) (6.) 6 8 7 (6.) (9.69) (.) (6.69) (.) (7.87) 8 7 (6.9) (9.69) (.) (6.69) (.) (7.87) Tolerance L: + / - mm (+ / -.8 inch) ) If a grounding plate is installed (attached to one side of the flange), this increases dimension L as follows: DN... by mm (.8 inch), DN and above by mm (.97 inch). ) If protection plates are installed (attached to both sides of the flange), this increases dimension L as follows: DN... by 6 mm (.6 inch), DN and above by mm (.9 inch). ) Depending on the device design, the dimensions change according to the following table. Device design Dimension E, F Standard temperature design High temperature version +7 mm (+ inch)

Electromagnetic Flowmeter FSM D8S7U.. Flange DN... (/... 8"), high-pressure version CL 6 88 (.6) (.8) C D F E Fig. 6: Dimensions in mm (inch) Cable gland M x. or NPT A L* G977 Flange in acc. with ASME B6., CL 6 Dimensions [mm (inch)] / [kg (lb)] DN PN ) D L ) ) F ) C E ) A Approx. weight (½) CL 6 9 7 8 6 (.7) (.6) (6.6) (.) (.96) (.). () CL 6 7 8 6 (.88) (.6) (6.6) (.) (.96) (.). ( ½) CL 6 6 8 6 9 (6.) (.) (6.) (.6) (.) (.). () CL 6 6 8 67 97 9 (6.) (.) (6.7) (.8) (.7) (.) 8.66 6 ( ½) CL 6 9 78 8 8 (7.) (.99) (7.) (.) (.9) (.9) 9.68 8 () CL 6 78 8 (8.) (.9) (7.) (.) (.9) (.9).7 () CL 6 7 7 (.7) (.7) (7.87) (.8) (6.77) (.9) 97. () CL 6 8 On request () (7.7) (8.7) (.) (7.7) (.9) (6) CL 6 7 6 9 66 On request () (7.7) (.) (.7) (9.) (6.) (8) CL 6 8 7 On request (6.) (9.69) (.) (6.69) (.) (7.87) Tolerance L: + / - mm (+ / -.8 inch) ) If a grounding plate is installed (attached to one side of the flange), this increases dimension L as follows: DN... by mm (.8 inch), DN and above by mm (.97 inch). ) If protection plates are installed (attached to both sides of the flange), this increases dimension L as follows: DN... by 6 mm (.6 inch), DN and above by mm (.9 inch). ) Depending on the device design, the dimensions change according to the following table. Device design Dimension E, F Standard temperature design High temperature version +7 mm (+ inch)

Electromagnetic Flowmeter FSM. Ordering information Information on A conformity: If A conformity is desired, please order model SE Welded Flange, Liner Material Thick-PTFE / PTFE / PFA / ETFE Main order number D8S7U Add. order no. Version number 6 7 8 9 6 7 8 9 6 7 8 XX Electromagnetic Flowmeter SEF- X X X X X X X X X X X X X X X X X X X X X X XX FSM Liner Material / Meter Size PFA / DN (/ in.) P PFA / DN (/ in.) P PFA / DN 6 (/ in.) P 6 PFA / DN 8 (/6 in.) P 8 PFA / DN (/8 in.) P PFA / DN (/ in.) P PFA / DN (/ in.) P PFA / DN ( in.) P PFA / DN (-/ in.) P PFA / DN (-/ in.) P PFA / DN ( in.) P PFA / DN 6 (-/ in.) P 6 PFA / DN 8 ( in.) P 8 PFA / DN ( in.) P H PFA / DN ( in.) P Q PFA / DN (6 in.) P F PFA / DN (8 in.) P H PTFE / DN (/8 in.) T PTFE / DN (/ in.) T PTFE / DN (/ in.) T PTFE / DN ( in.) T PTFE / DN (-/ in.) T PTFE / DN (-/ in.) T PTFE / DN ( in.) T PTFE / DN 6 (-/ in.) T 6 PTFE / DN 8 ( in.) T 8 PTFE / DN ( in.) T H PTFE / DN ( in.) T Q PTFE / DN (6 in.) T F PTFE / DN (8 in.) T H PTFE / DN ( in.) T F PTFE / DN ( in.) T H PTFE / DN ( in.) T F PTFE / DN (6 in.) T H PTFE / DN (8 in.) T F PTFE / DN ( in.) T H PTFE / DN 6 ( in.) T 6 H Thick PTFE / DN ( in.) F Thick PTFE / DN (-/ in.) F Thick PTFE / DN (-/ in.) F Thick PTFE / DN ( in.) F Thick PTFE / DN 6 (-/ in.) F 6 Thick PTFE / DN 8 ( in.) F 8 Thick PTFE / DN ( in.) F H Thick PTFE / DN ( in.) F Q Thick PTFE / DN (6 in.) F F Thick PTFE / DN (8 in.) F H Thick PTFE / DN ( in.) F F Thick PTFE / DN ( in.) F H ETFE / DN ( in.) E ETFE / DN (-/ in.) E ETFE / DN (-/ in.) E ETFE / DN ( in.) E ETFE / DN 6 (-/ in.) E 6 Continued on next page

Electromagnetic Flowmeter FSM D8S7U Main order number Add. order no. Version number 6 7 8 9 6 7 8 9 6 7 8 XX Electromagnetic Flowmeter SEF- X X X X X X X X X X X X X X X X X X X X X X XX FSM Liner Material / Meter Size ETFE / DN 8 ( in.) E 8 ETFE / DN ( in.) E H ETFE / DN ( in.) E Q ETFE / DN (6 in.) E F ETFE / DN (8 in.) E H ETFE / DN ( in.) E F ETFE / DN ( in.) E H ETFE / DN ( in.) E F ETFE / DN (6 in.) E H ETFE / DN (8 in.) E F ETFE / DN ( in.) E H ETFE / DN 6 ( in.) E 6 H ETFE / DN 7 (8 in.) E 7 H ETFE / DN 8 ( in.) E 8 H ETFE / DN 9 (6 in.) E 9 H ETFE / DN ( in.) E T Others / DN (/ in.) Z Others / DN (/ in.) Z Others / DN 6 (/ in.) Z 6 Others / DN 8 (/6 in.) Z 8 Others / DN (/8 in.) Z Others / DN (/ in.) Z Others / DN (/ in.) Z Others / DN ( in.) Z Others / DN (-/ in.) Z Others / DN (-/ in.) Z Others / DN ( in.) Z Others / DN 6 (-/ in.) Z 6 Others / DN 8 ( in.) Z 8 Others / DN ( in.) Z H Others / DN ( in.) Z Q Others / DN (6 in.) Z F Others / DN (8 in.) Z H Others / DN ( in.) Z F Others / DN ( in.) Z H Others / DN ( in.) Z F Others / DN (6 in.) Z H Others / DN (8 in.) Z F Others / DN ( in.) Z H Others / DN 6 ( in.) Z 6 H Measuring Electrodes Material / Grounding Electrodes Hastelloy C- (.6) / Without H Hastelloy B- (.6) / Without B AISI 6Ti SST (.7) / Without S Titanium / Without M Tantalum / Without T AISI 9L SST (.9) / Without F Platinum-Iridium / Without P Nickel / Without ) U Double Layer/ Without ) C Tungsten-Carbide / Without ) K Continued on next page ) Basic material Hastelloy C- ) >= DN ( in.)

Electromagnetic Flowmeter FSM D8S7U Main order number Add. order no. Version number 6 7 8 9 6 7 8 9 6 7 8 XX Electromagnetic Flowmeter FSM SEF- X X X X X X X X X X X X X X X X X X X X X X XX Measuring Electrodes Material / Grounding Electrodes Hastelloy C- (.6) / With ) O Hastelloy B- (.6) / With ) N AISI 6Ti SST (.7) / With ) E Titanium / With ) I Tantalum / With ) Q AISI 9L SST (.9) / With ) R Platinum-Iridium / With ) G Nickel / With ) V Double Layer / With ) D Pressure Rating PN, ISO lay length C PN 6, ISO lay length 6) D PN, ISO lay length E PN, ISO lay length 7) F JIS K, ISO lay length 8) K ASME CL, ISO lay length R ASME CL, ISO lay length 9) S Others Z Material of Process Connection Steel ) Stainless steel ) Accessories Without A Protection rings AISI 6Ti SST (.7) ) B Grounding ring AISI 6Ti SST (.7) ) C Others Z Temperature Range Standard design (<= C [66 F]) S High temperature design (<= 8 C [6 F]) ) H Certificates PED Standard A Material certificate. acc. EN with pressure test acc. ) D AD Pressure test acc. AD G Inspection certificate. acc. EN F Calibration Certificates Standard A Fingerprint saved at factory ) F Type of Protection / Cable Entry IP 67 / Thread for screw-type conduit fitting M x. IP 67 / Thread for screw-type conduit fitting NPT / in. IP 68 / Thread for screw-type conduit fitting M x. 6) 7 IP 68 / Cable connected and connection box potted 8 Continued on next page ) Basic material Hastelloy C- / Grounding electrodes <= DN (6 in.) ) Grounding electrodes <= DN (6 in.) ) >= DN ( in.) / Grounding electrodes <= DN (6 in.) 6) DN 6 (-/ in.) / PN 6 with connection dimensions acc. EN 9-: Please order PN 7) Standard for DN... DN 8 (/... in.) 8) <= DN ( in.) 9) <= DN (6 in.) ) >= DN (/ in. ) Standard for DN... DN (/... / in.), option from DN (/ in.) ) Protection rings mounted on both sides and ground rings mounted on one side to flange ) Only with Thick-PTFE / PFA >= DN ( in.) ) Material certificate for meter tube and flanges ) > DN8 (/6 in.) 6) Sealing compound (optional): DB8U

Electromagnetic Flowmeter FSM D8S7U Main order number Add. order no. Version number 6 7 8 9 6 7 8 9 6 7 8 XX Electromagnetic Flowmeter SEF- X X X X X X X X X X X X X X X X X X X X X X XX FSM Design Without pre-amplifier 7) With pre-amplifier type A 8) With pre-amplifier type B 9) Name Plate Language / Type German / Adhesive foil G English / Adhesive foil E French / Adhesive foil F German / Stainless steel J English / Stainless steel K French / Stainless steel L Design Level (Specified by ABB) x Lay Length Short, acc. ISO 9 A Electrode Design Standard Conical head, AISI 9L SST (.9) ) Swedish design, Hastelloy C- (.6) ) Signal Cable Length Without cable m (6 ft) m ( ft) m (66 ft) m ( ft) m ( ft) m (6 ft) 6 m (97 ft) 6 7 m ( ft) 7 8 m (6 ft) 8 9 m (9 ft) 9 m (8 ft) m ( ft) m (9 ft) 7 m (7 ft) 7 m (66 ft) Excitation Cable Length Without cable m (6 ft) m ( ft) m (66 ft) m ( ft) m ( ft) m (6 ft) 6 m (97 ft) 6 7 m ( ft) 7 8 m (6 ft) 8 9 m (9 ft) 9 m (8 ft) m ( ft) m (9 ft) 7 m (7 ft) 7 m (66 ft) Continued on next page 7) From DN (/8 in.) >= μs/cm 8) Standard up to DN 8 (/6 in.) >= μs/cm, option > DN 8 (/6 in.) >= μs/cm and cable length max. m (66 ft) 9) Option: Up to DN 8 (/6 in.) >= µs/cm, > DN 8 (/6 in.) >=. µs/cm and cable length max. m (66 ft) ) For application e.g. with high fat contents ) DN... DN (... 6 in.), for pulp applications with high resin contents

Electromagnetic Flowmeter FSM D8S7U Main order number Add. order no. Version number 6 7 8 9 6 7 8 9 6 7 8 XX Electromagnetic Flowmeter FSM SEF- X X X X X X X X X X X X X X X X X X X X X X XX Calibration points (standard) VK point standard calibration VC Witnessed calibration, calibration points ) VE point calibration acc. DAkkS ) VD Language of Documentation German M English M Russian MB Language package Western Europe / Scandinavia (Languages: DE, EN, DA, ES, FR, IT, NL, PT, FI, SV) MW Language package Eastern Europe (Languages: DE, EL, CS, ET, LV, LT, HU, PL, SK, SL, RO, BG) ME Others MZ Other Usage Certifications Russia - metrological and GOST-R certificate CG Kazakhstan - metrological and GOST-K certificate CG Ukraine - metrological certificate CG Belarus - Metrological Certificate CG6 ) Only available with FSM-S External Converter 6

Electromagnetic Flowmeter FSM D8S7U FSM-SEF Electromagnetic Flowmeter, AC technology, series aluminium housing, remote, welded flange, liner material Hard Rubber / Soft Rubber, Ceramic Carbide Add. Main order number order no. Version number 6 7 8 9 6 7 8 9 6 7 8 XX Electromagnetic Flowmeter SEF- X X X X X X X X X X X X X X X X X X X X X X XX FSM Liner Material / Meter Size Hard Rubber / DN (/ in.) H Hard Rubber / DN (/ in.) H Hard Rubber / DN ( in.) H Hard Rubber / DN (-/ in.) H Hard Rubber / DN (-/ in.) H Hard Rubber / DN ( in.) H Hard Rubber / DN 6 (-/ in.) H 6 Hard Rubber / DN 8 ( in.) H 8 Hard Rubber / DN ( in.) H H Hard Rubber / DN ( in.) H Q Hard Rubber / DN (6 in.) H F Hard Rubber / DN (8 in.) H H Hard Rubber / DN ( in.) H F Hard Rubber / DN ( in.) H H Hard Rubber / DN ( in.) H F Hard Rubber / DN (6 in.) H H Hard Rubber / DN (8 in.) H F Hard Rubber / DN ( in.) H H Hard Rubber / DN 6 ( in.) H 6 H Hard Rubber / DN 7 (8 in.) H 7 H Hard Rubber / DN 8 ( in.) H 8 H Hard Rubber / DN 9 (6 in.) H 9 H Hard Rubber / DN ( in.) H T Soft Rubber / DN ( in.) S Soft Rubber / DN 6 (-/ in.) S 6 Soft Rubber / DN 8 ( in.) S 8 Soft Rubber / DN ( in.) S H Soft Rubber / DN ( in.) S Q Soft Rubber / DN (6 in.) S F Soft Rubber / DN (8 in.) S H Soft Rubber / DN ( in.) S F Soft Rubber / DN ( in.) S H Soft Rubber / DN ( in.) S F Soft Rubber / DN (6 in.) S H Soft Rubber / DN (8 in.) S F Soft Rubber / DN ( in.) S H Soft Rubber / DN 6 ( in.) S 6 H Soft Rubber / DN 7 (8 in.) S 7 H Soft Rubber / DN 8 ( in.) S 8 H Soft Rubber / DN 9 (6 in.) S 9 H Soft Rubber / DN ( in.) S T Ceramic-Carbide / DN ( in.) ) C Ceramic-Carbide / DN (-/ in.) ) C Ceramic-Carbide / DN (-/ in.) ) C Ceramic-Carbide / DN ( in.) ) C Ceramic-Carbide / DN 6 (-/ in.) ) C 6 Ceramic-Carbide / DN 8 ( in.) ) C 8 Ceramic-Carbide / DN ( in.) ) C H Ceramic-Carbide / DN ( in.) ) C Q Ceramic-Carbide / DN (6 in.) ) C F Ceramic-Carbide / DN (8 in.) ) C H Ceramic-Carbide / DN ( in.) ) C F Ceramic-Carbide / DN ( in.) ) C H Ceramic-Carbide / DN ( in.) ) C F Continued on next page ) With Tungsten-Carbide electrode only / Protection rings mounted on both sides to flange. Material.7 (6Ti) 7

Electromagnetic Flowmeter FSM D8S7U Main order number Add. order no. Version number 6 7 8 9 6 7 8 9 6 7 8 XX Electromagnetic Flowmeter SEF- X X X X X X X X X X X X X X X X X X X X X X XX FSM Liner Material / Meter Size Ceramic-Carbide/ DN (6 in.) ) C H Ceramic-Carbide/ DN (8 in.) ) C F Ceramic-Carbide/ DN ( in.) ) C H Ceramic-Carbide/ DN 6 ( in.) ) C 6 H Ceramic-Carbide/ DN 7 (8 in.) ) C 7 H Ceramic-Carbide/ DN 8 ( in.) ) C 8 H Ceramic-Carbide/ DN 9 (6 in.) ) C 9 H Ceramic-Carbide/ DN ( in.) ) C T Others / DN (/ in.) Z Others / DN (/ in.) Z Others / DN ( in.) Z Others / DN (-/ in.) Z Others / DN (-/ in.) Z Others / DN ( in.) Z Others / DN 6 (-/ in.) Z 6 Others / DN 8 ( in.) Z 8 Others / DN ( in.) Z H Others / DN ( in.) Z Q Others / DN (6 in.) Z F Others / DN (8 in.) Z H Others / DN ( in.) Z F Others / DN ( in.) Z H Others / DN ( in.) Z F Others / DN (6 in.) Z H Others / DN (8 in.) Z F Others / DN ( in.) Z H Others / DN 6 ( in.) Z 6 H Others / DN 7 (8 in.) Z 7 H Others / DN 8 ( in.) Z 8 H Others / DN 9 (6 in.) Z 9 H Others / DN ( in.) Z T Measuring Electrodes Material / Grounding Electrodes AISI 6Ti SST (.7) / Without S Hastelloy C- (.6) / Without H Hastelloy B- (.6) / Without B Titanium / Without M Tantalum / Without T AISI 9L SST (.9) / Without F Platinum-Iridium / Without P Nickel / Without ) U Double Layer / Without ) C Tungsten-Carbide / Without ) K Continued on next page ) With Tungsten-Carbide electrode only / Protection rings mounted on both sides to flange. Material.7 (6Ti) ) Basic material Hastelloy C- ) >= DN ( in.) 8

Electromagnetic Flowmeter FSM D8S7U Main order number Add. order no. Version number 6 7 8 9 6 7 8 9 6 7 8 XX Electromagnetic Flowmeter FSM SEF- X X X X X X X X X X X X X X X X X X X X X X XX Measuring Electrodes Material / Grounding Electrodes Hastelloy C- (.6) / With ) O Hastelloy B- (.6) / With ) N AISI 6Ti SST (.7) / With ) E Titanium / With ) I Tantalum / With ) Q AISI 9L SST (.9) / With ) R Platinum-Iridium / With ) G Nickel / With 6) V Double Layer / With ) D Pressure Rating PN, ISO laid length C PN 6, ISO laid length 7) D PN, ISO laid length E PN, ISO laid length 8) F PN 6 9) G PN 9) H JIS K, ISO laid length ) K ASME CL, ISO laid length R ASME CL, ISO laid length ) S ASME CL 6 9) T Others Z Material of Process Connection Steel ) Stainless steel ) Accessories Without A Others Z Temperature Range Standard design (<= C [66 F]) S Certificates PED Standard A Material certificate. acc. EN with pressure test acc. ) D AD Pressure test acc. AD G Inspection certificate. acc. EN F Calibration Certificates Standard A Fingerprint saved at factory ) F Type of Protection / Cable Entry IP 67 / Thread for screw-type conduit fitting M x. IP 67 / Thread for screw-type conduit fitting NPT / in. IP 68 / Thread for screw-type conduit fitting M x. 6) 7 IP 68 / Cable connected and connection box potted 8 Continued on next page ) Basic material Hastelloy C- / Grounding electrodes <= DN (6 in.) ) Grounding electrodes <= DN (6 in.) 6) >= DN ( in.) / Grounding electrodes <= DN (6 in.) 7) DN 6 (-/ in.) / PN 6 with connection dimensions acc. EN 9-: Please order PN 8) Standard for DN... DN 8 (/... in.) 9) <= DN (8 in.) / Hard Rubber only ) <= DN ( in.) ) <= DN 6 ( in.) ) >= DN (/ in.) ) Standard for DN (/ in.), option from DN (/ in.) ) Material certificate for meter tube and flanges ) > DN8 (/6 inch) 6) Sealing compound (optional): DB8U 9

Electromagnetic Flowmeter FSM D8S7U Main order number Add. order no. Version number 6 7 8 9 6 7 8 9 6 7 8 XX Electromagnetic Flowmeter SEF- X X X X X X X X X X X X X X X X X X X X X X XX FSM Design Without pre-amplifier 7) With pre-amplifier type A 8) With pre-amplifier type B 9) Name Plate Language / Type German / Adhesive foil G English / Adhesive foil E French / Adhesive foil F German / Stainless steel J English / Stainless steel K French / Stainless steel L Design Level (Specified by ABB) x Lay Length Short, acc. ISO 9 A Electrode Design Standard Conical head, AISI 9L SST (.9) ) Signal Cable Length Without cable m (6 ft) m ( ft) m (66 ft) m ( ft) m ( ft) m (6 ft) 6 m (97 ft) 6 7 m ( ft) 7 8 m (6 ft) 8 9 m (9 ft) 9 m (8 ft) m ( ft) m (9 ft) 7 m (7 ft) 7 m (66 ft) Excitation Cable Length Without cable m (6 ft) m ( ft) m (66 ft) m ( ft) m ( ft) m (6 ft) 6 m (97 ft) 6 7 m ( ft) 7 8 m (6 ft) 8 9 m (9 ft) 9 m (8 ft) m ( ft) m (9 ft) 7 m (7 ft) 7 m (66 ft) Continued on next page 7) >= μs/cm 8) Option >= μs/cm and cable length max. m (66 ft) 9) Option >=. µs/cm and cable length max. m (66 ft) ) For application e.g. with high fat contents

Electromagnetic Flowmeter FSM D8S7U Main order number Add. order no. Version number 6 7 8 9 6 7 8 9 6 7 8 XX Electromagnetic Flowmeter FSM SEF- X X X X X X X X X X X X X X X X X X X X X X XX Calibration Points (Standard) VK Point Standard Calibration VC Witnessed calibration, calibration points ) VE point calibration acc. DAkkS ) VD Language of Documentation German M English M Russian MB Language package Western Europe / Scandinavia (Languages: DE, EN, DA, ES, FR, IT, NL, PT, FI, SV) MW Language package Eastern Europe (Languages: DE, EL, CS, ET, LV, LT, HU, PL, SK, SL, RO, BG) ME Others MZ Other Usage Certifications Russia - metrological and GOST-R certificate CG Kazakhstan - metrological and GOST-K certificate CG Ukraine - metrological certificate CG Belarus - Metrological Certificate CG6 ) Only available with FSM-S External Converter

Electromagnetic Flowmeter FSM Model SE_. Specifications Change from one to two columns Minimum Allowable Absolute Pressure Lining Nominal diameter DN PFA (/ ) Peek/Torlon (/ / ) P Operation mbar abs at T Operating ) C C (66 F) C (8 F) ) Higher temperatures are allowed for CIP / SIP cleaning for limited time periods, see the table titled "Max. allowable cleaning temperature". Maximum Allowable Cleaning Temperature CIP cleaning Lining T max T max Minutes Steam cleaning PFA / Peek C ( F) Wet cleaning PFA / Peek / Torlon C (8 F) T amb. 6 C (77 F) 6 C (77 F) If the ambient temperature is > C (77 F), then the difference must be subtracted from the max. cleaning temperature. T max C, C = (T amb - C) Maximum Allowable Temperature Shock Lining Temp Shock max. Temp. Diff. C Temp. gradient C/min PFA Any Any Peek, Torlon Any Any Maximum allowable ambient temperature as function of fluid temperature T amb. C ( F) - Fig. 7: DN... DN 6 () () - 9 (9) (F) - DN... DN (8) () - (-) Temperature graph The flowmeter sensor must not be isolated. (66) G T Measuring C ( F) Fluid temperature DN DN (/... /") - C (... 8 F), max. allowable cleaning temperature, see table. D8S7U Flowmeter material Lining Electrode material Electrode design PFA, Peek, Torlon Standard Others Standard Others Hast.-C (.6) (.9 [9 L] for pipe conn. and Tri-Clamp) Hast.-B (.6),.9 (9 L),.7 (6 Ti), Titanium, tantalum, Platinumiridium Flat head /8" sanitary connectors always with grounding electrodes in material for signal electrodes, standard. Pointed head ( DN ).9 (9 L) Process connection material Process connection Standard Option Flange Stainless steel.7 (6 Ti) On rqst. Wafer type None Weld stubs Stainless steel. (6 L) Threaded pipe connection Stainless steel. (6 L) Tri-Clamp Stainless steel. (6 L) External threads Stainless steel. (6 L) /8" sanitary connectors Terminal box - without/with preamplifier, type A - with preamplifier, type B Stainless steel.7 (6 Ti) Stainless steel. () Al alloy, painted, paint coat frame: dark gray, RAL 7 cover: light gray, RAL 9 On rqst. On rqst. On rqst. On rqst. POM, brass, PVC Meter tube Stainless steel. () cable gland used Polyamide PVDF Flowmeter sensor housing Stainless steel. () Gasket material (internal) Process connection Standard Wafer type None Weld stubs Threaded pipe connection Tri-Clamp External threads /8" sanitary connectors Flat gaskets EPDM (Ethylene- Propylene) with FDA approval, silicone with FDA approval (CIPresistant, no oils or grease) PTFE Silicon (resistant to oil, grease) Option Silicon with FDA approval (optional, resistant to oils and grease) PTFE with FDA approval (DN... 8) Viton (only in combination with PVC process connection)

Electromagnetic Flowmeter FSM D8S7U Storage temperature - 7 C (-... 8 F) Degree of protection acc. to EN 69 IP 67 IP 68 (option) Pipeline vibration according to EN 668--6 Transmitter - In the range of Hz, max. deflection. mm Flowmeter sensor - In the range of Hz, max. deflection. mm - In the range of Hz, max. acceleration g Materialload for meters with variable process connections / wafer type SE DN... DN (/... ") Process Nominal connection diameter Liner PFA DN Wafer type (/ ) 6 ( / ) Weld stubs (/ / ) ; 8 (, ) 6, Threaded pipe connection conforming to DIN 8 Tri-Clamp conforming to DIN 676 Tri-Clamp in acc. with ASME BPE External threads ISO 8 /8" sanitary connectors ( / ) (/ / ) ; 8 (, ) 6, ( / ) (/ ) 6 ( / )... (/... ) (/ (/ / ) PS max [bar] 6 6 6 6 TS min - C (- F) - C (- F) - C (- F) - C (- F) - C (- F) 6 - C (- F) - C ( F) TS max C (66 F) C (66 F) C (66 F) C ( F) C (66 F) C (66 F) C (8 F) JIS B-K wafer type Meter size DN (¼ ) Material PN TS PS [bar]. (6 L),. (6 L),. () Material load for flange model SEF Lining: PFA PS [bar] PN PN PN 6 PN - C (- 66 F) PS [psi] 6. 8. 7.. 6. 9. 7.. - - - 6 7 8 9 *) [ C] - - 68 86 8 76 9 8 66 *) [ F] TS 7. G Fig. 8: DIN flange, stainless steel.7 (6 Ti) up to DN (") Liner PFA PS [bar] CL CL PS [psi] 697. 7. 6. 8. 7.. 6. 9. 7.. - - 7 9 *) [ C] - 86 8 9 66 *) [ F] TS Fig. 9: ASME flange, stainless steel.7 (6 Ti) up to DN (") 7. G Material load for flange model SEW Lining: PFA wafer type PS [bar] PN /CL PS [psi] 6. 8. 7.. PN PN 6/CL PN -6 - - - - - 6 7 8 9 *) [ C] TS -76-8 - - - 68 868769 866 *) [ F] Fig. 6. 9. 7.. 7. G *) For CIP / SIP cleaning, higher temperatures are permitted for limited time periods; refer to the table titled "Maximum permissible cleaning temperature".

Electromagnetic Flowmeter FSM D8S7U Change from one to two columns. Dimensions.. Model SEF Stainless steel housing, flange acc. to DIN / EN 9-, DN... DN ; ASME B6., /... /" (,9) 8 (,) (,6) F E Ød ØD F E G G 7 (,8) Ød A L b k D G9 Fig. : Dimensions in mm (inch) Cable gland M x. or NPT Number of holes N Flange dimensions acc. to DIN / EN, liner PFA Weight DN PN mm L ) A D k d d b E F G approx. kg... 8 ) 7 9 6 8 6 9., 7 9. 9 6 6 8 6 9. 7 66 7.... 8 7 8 6 6 78 9 67 7 8 7. DN PN inch L ) A D k d d b E F G Approx. lb... 8 )..6..6.6..7...., 7.87.6.,.7.6...7.... 7.87.6..9.6..79.6.69.9.... 7.87......79.87.89.67 6.6 7.87...9...79.7.9.87 8.8 7.87.6.9..9..79.. 6. 9.9 ) If a grounding plate is required, L + mm (."), material upon request. With grounding plates (protection plates) L + 6 mm (."), material upon request. ) Connecting dimensions acc. to EN9- ) Connection flange DN (/8") ) Connection flange /"

Electromagnetic Flowmeter FSM D8S7U Inch /... /6 ) PN Flange dimensions acc. to ASME B6., liner PFA Weight mm approx. kg L ) A D k d d b E F G 7 88.9 6...9 8. 6 9. /8 ), / 7 88.9 6..8.9.6 6 9. / 98. 69.8.9.9. 66 7. CL 8. 79..8.9.8 7 8 / 6 7. 88.9 6..9 7. 78 9 / 67 7. 98.6 7..9 9. 8 7. /... /6 ) 7 9. 66.7..9 8. 6 9. /8 ), / 7 9. 66.7.8.9.8 6 9. / 7. 8..9 9. 7. 66 7. CL.8 88.9.8 9. 9. 7 8 / 6. 98. 6. 9.. 78 9 / 67.6. 7... 8 7. Inch /... /6 ) PN inch Approx. lb L ) A D k d d b E F G..6..7.6.6.7.... /8 ), / 7.87.6..7.7.6..... / 7.87.6.87.7.69.6.6.6.69.9. CL 7.87.....6.6.87.89.67 6.6 / 7.87..6...6.69.7.9.87 6.6 / 7.87.6..88.87.6.7.. 6. 7.7 /... /6 )..6.7.6.6.6.7.... /8 ), / 7.87.6.7.6.7.6.6.... / 7.87.6.6..69.7.69.6.69.9. CL 7.87..87...7.7.87.89.67 6.6 / 7.87...87..7.8.7.9.87 8.8 / 7.87.6 6...87.87.87.. 6. 9.9 ) If a grounding plate is required, L + mm (."), material upon request. With grounding plates (protection plates) L + 6 mm (."), material upon request. ) Connecting dimensions acc. to EN9- ) Connection flange DN (/8") ) Connection flange /"

Electromagnetic Flowmeter FSM D8S7U Stainless steel housing, flange acc. to DIN / EN 9-, DN... DN ; ASME B6.,... " 8 (,) (,6) G 7 (,8) d Ød ØD G E E A L b G Fig. : Dimensions in mm (inch) Cable gland M x. or NPT Number of holes N Flange dimensions acc. to DIN / EN, liner PFA Weight DN PN mm L ) A D k d d N b E G approx. kg... 6 8 9 6 8 6 )... 6... 7 7 8 8 8 8 8 6 6 76 76 8... 7 6 9 8 8 8 8... 6... 9 9 8 9 6 67 inch DN PN L ) A D k d d N b E G... 7.87.9 6..9.9.7.6.9. 6. 7.6 6 )... 6... 7.87 7.87.. 7.8 7.8.7.7.88.88 8.7.7 8 8.6. 8.. 8 8.. 99 99 6.9 6.9 8 8 Approx. lb 8... 7.87. 7.87 6..7.7...9 7.8 6.... 6 9.8 6.6 8.66 7.9 6..7..9. 7.8 9.7... 9.8 6.6 9. 7.8 6.7.87... 7.8 9.7 ) If a grounding plate is required, L + mm (."), material upon request. With grounding plates (protection plates) L + 6 mm (."), material upon request. ) For DN 6/PN 6 acc. to EN 9- please order PN... 6

Electromagnetic Flowmeter FSM D8S7U Flange dimensions acc. to ASME B6., liner PFA Weight mm Inch PN approx. kg L ) A D k d d N b E G 99 9 9 6 8 / 7 78 8 9 6 76 CL 7 9 9 8 8 9 9 9 7 9 8 8 8 99 8 6 7 9 8 6 9 6 8 / 7 9 9 8 9 76 CL 7 68 8 8 9 77 8 6 8 99 8 inch Inch PN Approx. lb L ) A D k d d N b E G 7.87.9.98.76.9.7.6.9. 6. 7.6 / 7.87. 7...6.7.6.. 6.9. CL 7.87. 7..98.6.7.6..9 7.8 6. 9.8 6.6 9. 7.8 6.7.7... 7.8 9.7 7.87.9 6....7... 6. 7.6 / 7.87. 7..87.88.87... 6.9. CL 7.87. 8.7 6.6.6.87..6.9 7.8 6. 9.8 6.6. 7.87 6.97.87... 7.8 9.7 ) If a grounding plate is required, L + mm (."), material upon request. With grounding plates (protection plates) L + 6 mm (."), material upon request. 7

Electromagnetic Flowmeter FSM D8S7U.. Model SEW Stainless steel housing, wafer type DN... DN (/... ") DN... DN (/... ½") 8 (,) (,6) E G 7 (,8) F A ØDi ØC ØD J DN... DN 8 (/... /6 ) 7 (,6) B A* L x Ø, (, ) C ØDi Ø.6 G DN... DN (... ") 8 (,) (,6) F ØDi ØC ØD E G 7 (,8) A* L G9 Fig. : Dimensions in mm (inch) Cable gland Pg. or NPT Pattern for axial holes Hole pattern Mounting bracket (optional) 8

Electromagnetic Flowmeter FSM D8S7U DN (inch) (/) (/) 6 (/) 8 (/6) (/8) (/) PN... CL CL JIS Wafer type dimensions mm L )) L )) A* A B C ØC ØDi ØD E F G J 68 68 6 7 8 6 8 6 9 7 8 (/) 78 78 7 8 8 66, () 9 9 86 6 7 9 6 7 8 9, ( /) 98 98 9 6 7 69 7 78 9, ( /) 99 6 7 77 6 8 8 7 7, () 7 7 6 9 7 9, 6 ( /)... 6 99 6 6 6 8, 8 () CL JIS 99 6 8 7 67 6, () 9 6 96 6 8 8 79 8, DN (inch) (/) (/) 6 (/) 8 (/6) (/8) (/) PN... CL CL JIS inch L )) L )) A* A B C ØC ØDi ØD E F G J.68 68..6..97.6..6...9..77.. 6.77..6 (/).7 78.9.6..97.97.7..6.69 8.7.6. (). 9.9.6.8.76..9.8.87.89 8.6.6. ( /).86 98.7.6.8.76.7.8.87.7.9 9..6. ( /).6.9.6.8.76..... 9..6 6.6 ().6 7..6..7.8.9..97 8.9 8.8 6 ( /)... 6.6 7,87.9.6..7..7..8 9. 9.9 8 () CL JIS.6 7,87.9.6...9..9.6 9.9. (). 9,8.8.6. 6..78 6....98 8.7 ) Installation lengths with ground plates L + mm (.") ) Old lay length. Please refer to the model coding to specify the lay length (old lay length / new lay length). Old Lay Length for replacement purposes only ) New Lay Length. Mounting bracket (optional) With mounting bracket, combined height + 7 mm (.6") DN... DN (/... ½"), +. mm (.") DN... DN (... "). Weight approx. kg, Appro x. lb. 9

Electromagnetic Flowmeter FSM D8S7U.. Model SE_ Variable process connection DN... DN (/... ½") (,9) 8 (,) 8 (,) (,6) G E 7 (,8) F A ØD x Ø. (,) 7 (,6) B C G DN... DN (... ") (,9) 8 (,) 8 (,) (,6) 7 (,8) 6 G E (,), (,) F ØD Fig. : Dimensions in mm (inch) Cable gland Pg. or NPT Pattern for axial holes Mounting bracket (optional) x Ø. B DN 6... ( /... ) 6 x Ø. Hole pattern L Pipe Number of holes N C DN () G

Electromagnetic Flowmeter FSM D8S7U DN (inch) Variable process connection mm A ØD B C E F G L Pipe ) L Pipe ) N... (/... /8) 7 8 6 9 7 8 8. Weight appr. kg ) (/) 7 8 6 9 7 8 8. (/) 6 8 66 8 9 9. () 6 6 7 7 8 9. ( /) 78 6 7 78. ( /) 78 6 7 8 7. () 6 9 8 8 8. 6 ( /) 6 6 8. 8 () 6 67 6 6. () 6 6 8 8 79 6 9. DN (inch) inch A ØD B C E F G L Pipe ) L Pipe ) N... (/... /8).6.7..97.. 6.77.,. (/).6.7..97.. 6.77.,. (/).6.8..97.6.69 7.9.,. ().6.8.8.76.87.89 7.6.,. ( /).6.7.8.76.7.9 7.9.7,7. ( /).6.7.8.76.. 8.7.9,9 6.6 ().9.6...97 8..,. 8.8 6 ( /).7.6...8 9..9 7,87.9 9.9 appr. lb ) 8 ()..6..9.6 9.9.9 7,87.. () 6..6....98.9 9,8. 9.8 ) For process connection weights see page. ) Old lay length. Please refer to the model coding to specify the lay length (old lay length / new lay length). Old Lay Length for replacement purposes only ) New Lay Length. Mounting bracket (optional) With mounting bracket, combined height +7 mm (.6") DN... DN (/... ½"), +. mm (.") DN... DN (... ").

Electromagnetic Flowmeter FSM D8S7U. Adapter for variable process connections DN... (/... ") L L Di Da R Di Da a Fig. L L G7 Weld stubs Tri-Clamp Threaded pipe connection in acc. with DIN 8 External threads Weld stubs Dimensions in mm ISO 7 DIN 8 SMS DIN 6 ISO 7 Weight DN Ø Di Ø Da Ø Di Ø Da Series Ø Di Ø Da Ø Di Ø Da Ø Di Ø Da Series L ) L ) [kg]... - -,,,, 7 7,, 7, 6 9 - - 8,, 8,, 7 7, 9,, - -,7 6,9,7 6,9,7,6 6 9,6 8,7 6,9 9 9,7,,7 - -,,7 66 66,6 8 8,6 8 6,8 9, 7 7 8,6 8,6 9 7,8 7 7 6 6, 6, 66 7 6, 6, 66 7 66 7 6, 8 7,9 76, 8 8 7,9 76, 8 8 7,9 76, 69 97,6,6 97,6,6 99 Dimensions in inches ISO 7 DIN 8 SMS DIN 6 ISO 7 Weight DN Ø Di Ø Da Ø Di Ø Da Series Ø Di Ø Da Ø Di Ø Da Ø Di Ø Da Series L ) L ) [lb] / /8.9.7.9. - -.....88 /.6.68.6.7 - -.7.8.7.8.88 /.76.8.79.9 - -.9.6.9.6....89.98...89.98.98..9.6.87.87. /...6. - -.6.8.. 6. 6.. /....6....7..66 6.7 6.7..9..97.9.9..9..88. 6.8 6.8. /.7..6.76.7..6.76.6.76 6. 9.88.9.87.9..87.9..87 6.6...8.9.9.9.9.9.9.8 7.8. 6.6 ) Old Lay Length. Please refer to the model coding to specify the lay length (old lay length / new lay length). Old Lay Length for replacement purposes only. ) New Lay Length.

Electromagnetic Flowmeter FSM D8S7U Other variable process connections Dimensions in mm Threaded pipe connection Tri-Clamp DIN 8 DIN 676 ASME BPE DN Weight Weight Tri- Weight Rd. thd. L Ø Di Ø Da Series L Ø Di Ø Da L [kg] [kg] Clamp [kg]... 8 x /8 69 ) 6,, / 9, 69 ) 6 ) ), x /8 69 ) 6, 6, /,7 69 ) 6 ) ), x /6 8 ) 68,9,7,, 8 ) 68 ) ),7 x /6 7 ) 9,9 6,,8,, 7 ) 9 ) ), 8 x /6 ) 9,, ) 9 ), - - - - - 6 x /6 7 ), 8, 77, /,8, 7 ) ) 77 ),8 78 x /6 ) 6, 6, 77, 7, 6,9 ) 6 ) 77 ),8 6 96 x /6 ), 66 9, 77,6 / 6, 77, ) 7 ) 77 ), 8 x / 9 ), 8 6 7, 7,9 9,9 ) ) 7 ),6 x / 7 ), 9 7, 97, 8,9 ) 6 ) 7 ), Dimensions in inches Threaded pipe connection Tri-Clamp DIN 8 DIN 676 ASME BPE DN Weight Weight Tri- Weight Rd. thd. L Ø Di Ø Da Series L Ø Di Ø Da L [lb] [lb] Clamp [lb] / 6,6. x /8 6,,,9,,6, /,7,98 /8 6,6 ) 6, ),6 ), /. x /8 6,6 ) 6,,,6,,6, /,6,98 6,6 ) 6, ),6 ), /.7 x /6 7,9 ) 6,6,98,79,,6,,87,98 7,9 ) 6,6 ),6 ),. x /6 8, ) 7,6,98,,99,6,76,87,98 8, ) 7,6 ),6 ),6 /.8 x /6 9,6 ) 8,,9,6,99 9,6 ) 8, ), - - - - - /.6 x /6 9, ) 8,,9,,99,9,9 /,7,98 9, ) 8, ),9 ),97.7 x /6 9,7 ) 8,,9,97,,9,6,87, 9,7 ) 8, ),9,97 /.78 x /6 9,6 ) 8,7,8,6,8,9, /,7,, ),9 ),9,. x /, ) 8,86 7,,9,7,7,9,87,8,8 ), ),7 ) 7,9. x /,9 ), 9,7,9,69,7 6,8,8,68 6,6 ), ),7 ) 8,8 ) Old Lay Length. Please refer to the model coding to specify the lay length (old lay length / new lay length). Old Lay Length for replacement purposes only. ) New Lay Length.

Electromagnetic Flowmeter FSM D8S7U External threads ISO 8 / DIN 999, tapered Dimensions in mm DN R a L Weight [kg]... /8 8 9. / 8 9. / 6.8 79.8 Dimensions in inches DN R a L Weight [lb] /... /8 /8.7.7.88 / /.7.7.88 / /.98 6.6.76.98 7..76 Weld stubs suitable for OD tubing Dimensions in mm DN Weld stub size Di Da L Weight [kg] (/8 ) / 9..7 7. (/ ) /.7 9. 7. ( )...7 ( ).. 9 ( / ) /.8 8. 7 ( ) 7..8 7 Dimensions in inches DN Weld stub size Di Da L Weight [lb] (/8 ) /.7..9 (/ ) /.6.7.9 ( ).87.. ( ).87.87. ( / ) /.7. 6.7. ( ).87 6.8.

Electromagnetic Flowmeter FSM D8S7U.. Model SEB /8" sanitary connectors, DN... DN (/... /") C D E F 8 (,89) A B 8 (,89) (,7) (,7) Fig. 6: Dimensions in mm (inch) Gaskets Connecting dimensions for gland G /8" internal thread 6 (,) x Ø. 6 (,6) (,7) 9 (,) (,98) (,) 69 (,7) Cable gland Pg. or NPT Mounting bracket, standard G6 Important The flowmeter sensor is equipped as standard with grounding electrodes in the same material as the measuring electrodes. The flowmeter sensor can only be operated on S transmitters with software version B. or higher. Preamplifier A B C D E F Without / type A 9 (.68) 7 (.79) 6 (.) (.7) 8 (.) (.6) Type B (.9) 6 (.) 6 (6.) 7 (.79) (.9) 7 (.7) Process Connection DN PN Weight kg /8" sanitary connectors )... (/... /"). (. lb) ) For hose 6 x mm

Electromagnetic Flowmeter FSM D8S7U. Ordering information FSM-SEF, AC technology, series stainless steel housing, remote, welded flange, liner material PFA Add. Main order number order no. Version number 6 7 8 9 6 7 8 9 6 7 8 XX Electromagnetic Flowmeter SEF- X X X X X X X X X X X X X X X X X X X X X X XX FSM Process Connection Welded flange DIN / ASME F Liner Material / Meter Size PFA / DN (/ in.) P PFA / DN (/ in.) P PFA / DN 6 (/ in.) P 6 PFA / DN 8 (/6 in.) P 8 PFA / DN (/8 in.) P PFA / DN (/ in.) P PFA / DN (/ in.) P PFA / DN ( in.) P PFA / DN (-/ in.) P PFA / DN (-/ in.) P PFA / DN ( in.) P PFA / DN 6 (-/ in.) P 6 PFA / DN 8 ( in.) P 8 PFA / DN ( in.) P H Measuring Electrodes Material / Grounding Electrodes Hastelloy C- (.6) / Without H Hastelloy B- (.6) / Without B AISI 6Ti SST (.7) / Without S Titanium / Without M Tantalum / Without T AISI 9L SST (.9) / Without ) F Platinum-Iridium / Without P Hastelloy C- (.6) / With O Hastelloy B- (.6) / With N AISI 6Ti SST (.7) / With E Titanium / With I Tantalum / With Q AISI 9L SST (.9) / With ) R Platinum-Iridium / With G Pressure Rating PN 6 ) D PN F ASME CL P ASME CL Q Material of Process Connection AISI 6Ti SST (.7) Accessories Without A Protection rings AISI 6Ti SST (.7) ) B Grounding ring AISI 6Ti SST (.7) ) C Temperature Range Standard design (<= C [66 F]) (DN... DN : max. C [8 F]) S Certificates PED Standard A Material certificate. acc. EN with ) D pressure test acc. AD Pressure test acc. AD G Inspection certificate. acc. EN F Calibration Certificates Standard A Fingerprint saved at factory ) F Continued on next page ) For food and beverage applications ) DN 6 (-/ in.) / PN 6 with connection dimensions acc. EN 9-: Please order PN ) Protection rings mounted on both sides and ground rings mounted on one side to flange ) Material certificate for meter tube and flanges ) > DN 8 (/6 in.) 6

Electromagnetic Flowmeter FSM D8S7U Main order number Add. order no. Variantenstelle 6 7 8 9 6 7 8 9 6 7 8 XX Electromagnetic Flowmeter FSM SEF- X X X X X X X X X X X X X X X X X X X X X X XX Type of Protection / Cable Entry IP 67 / Thread for screw-type conduit fitting M x. IP 67 / Thread for screw-type conduit fitting NPT / in. IP 68 / Thread for screw-type conduit fitting M x. 6) 7 IP 68 / Cable connected and connection box potted 8 Design Without pre-amplifier 7) With pre-amplifier type A 8) With pre-amplifier type B 9) Name Plate Language / Type German / Adhesive foil G English / Adhesive foil E French / Adhesive foil F German / Stainless steel J English / Stainless steel K French / Stainless steel L Design Level (Specified by ABB) x Electrode Design Standard Conical head, AISI 9L SST (.9) ) Signal Cable Length Without cable m (6 ft) m ( ft) m (66 ft) m ( ft) m ( ft) m (6 ft) 6 m (97 ft) 6 7 m ( ft) 7 8 m (6 ft) 8 9 m (9 ft) 9 m (8 ft) m ( ft) m (9 ft) 7 m (7 ft) 7 m (66 ft) Excitation Cable Length Without cable m (6 ft) m ( ft) m (66 ft) m ( ft) m ( ft) m (6 ft) 6 m (97 ft) 6 7 m ( ft) 7 8 m (6 ft) 8 9 m (9 ft) 9 m (8 ft) m ( ft) m (9 ft) 7 m (7 ft) 7 m (66 ft) Continued on next page 6) Sealing compound (optional): DB8U 7) From DN (/8 in.) >= μs/cm 8) Standard up to DN 8 (/6 in.) >= μs/cm, > DN 8 (/6 in.) >= μs/cm and lay length max. m (66 ft) 9) Option: Up to DN 8 (/6 in.) >= µs/cm, > DN 8 (/6 in.) >=. µs/cm and lay length max. m (66 ft) ) For application e.g. with high fat contents 7

Electromagnetic Flowmeter FSM D8S7U Main order number Add. order no. Variantenstelle 6 7 8 9 6 7 8 9 6 7 8 XX Electromagnetic Flowmeter FSM SEF- X X X X X X X X X X X X X X X X X X X X X X XX Calibration points (standard) VK point standard calibration VC Witnessed calibration, calibration points ) VE point calibration acc. DAkkS ) VD Language of Documentation German M English M Russian MB Language package Western Europe / Scandinavia (Languages: DE, EN, DA, ES, FR, IT, NL, PT, FI, SV) MW Language package Eastern Europe (Languages: DE, EL, CS, ET, LV, LT, HU, PL, SK, SL, RO, BG) ME Others MZ Other Usage Certifications Russia - metrological and GOST-R certificate CG Kazakhstan - metrological and GOST-K certificate CG Ukraine - metrological certificate CG Belarus - Metrological Certificate CG6 Lay Length Old length for DN - JE New length for DN 6, DN 8, DN JF ) Only available with FSM-S External Converter 8

Electromagnetic Flowmeter FSM D8S7U Wafer Type / /8 in. Sanitary Connection / Variable Process Connections, Liner Material Torlon, PEEK, PFA Main order number Add. order no. Version number 6 7 8 9 6 7 8 9 6 7 8 XX Electromagnetic Flowmeter SE- X X X X X X X X X X X X X X X X X X X X X X X XX FSM Process Connection Wafer type W Weld stubs DIN 8 R Weld stubs DIN 6 Q Weld stubs ISO 7 J Weld stubs SMS X Without adapter ) V Weld stubs ISO 7 P Pipe connection acc. DIN 8 S Tri-Clamp DIN 676 T Tri-Clamp ASME BPE K Male thread acc. ISO 8 / DIN E 999 (conical) /8 in. Pipe thread B Liner Material / Meter Size PEEK / DN (/ in.) K PEEK / DN, (/6 in.) K S PEEK / DN (/ in.) K Torlon / DN (/ in.) N Torlon / DN, (/6 in.) N S Torlon / DN (/ in.) N PFA / DN (/ in.) P PFA / DN (/ in.) P PFA / DN 6 (/ in.) P 6 PFA / DN 8 (/6 in.) P 8 PFA / DN (/8 in.) P PFA / DN (/ in.) P PFA / DN (/ in.) P PFA / DN ( in.) P PFA / DN (-/ in.) P PFA / DN (-/ in.) P PFA / DN ( in.) P PFA / DN 6 (-/ in.) P 6 PFA / DN 8 ( in.) P 8 PFA / DN ( in.) P H Measuring Electrodes Material / Grounding Electrodes Hastelloy C- (.6) / Without H Hastelloy B- (.6) / Without B AISI 6Ti SST (.7) / Without S Titanium / Without M Tantalum / Without T AISI 9L SST (.9) / Without ) F Platinum-Iridium / Without P Hastelloy C- (.6) / With O Hastelloy B- (.6) / With N AISI 6Ti SST (.7) / With E Titanium / With I Tantalum / With Q AISI 9L SST (.9) / With ) R Platinum-Iridium / With G Pressure Rating PN C PN 6 D PN F ASME CL P ASME CL Q Continued on next page ) Spare sensor, for replacement only ) For food and beverage applications 9

Electromagnetic Flowmeter FSM D8S7U Main order number Add. order no. Version number 6 7 8 9 6 7 8 9 6 7 8 XX Electromagnetic Flowmeter FSM SE- X X X X X X X X X X X X X X X X X X X X X X X XX Material of Process Connection Without AISI 6Ti SST (.7) ) AISI 6L SST (.) PVC ) 7 POM ) 8 Accessories Without 6) A With fastening element 7) C Temperature Range Standard design (<= C [66 F]) (DN... DN : max. S C [8 F]) Certificates PED Standard A Material certificate. acc. EN with pressure test 8) D AD Pressure test AD G Inspection certificate. acc. EN F Calibration Certificates Standard A Fingerprint saved at factory 9) F Type of Protection / Cable Entry IP 67 / Thread for screw-type conduit fitting M x. IP 67 / Thread for screw-type conduit fitting NPT / in. IP 68 / Thread for screw-type conduit fitting M x. ) 7 IP 68 / Cable connected and connection box potted 8 Design Without pre-amplifier ) With pre-amplifier type A ) With pre-amplifier type B ) Name Plate Language / Type German / Adhesive foil G English / Adhesive foil E French / Adhesive foil F German / Stainless steel J English / Stainless steel K French / Stainless steel L Design Level (Specified by ABB) x Electrode Design Standard Conical head, AISI 9L SST (.9) ) Continued on next page ) Standard at /8 in. pipe thread and welded flange ) DN... DN (/... / in.) see gasket ) DN... DN (/... / in.) 6) > DN (/ in.) 7) No -A conformity 8) From DN (/ in.) 9) From DN (/8 in.) ) Sealing compound (optional): DB8U ) From DN (/8 in.) >= μs/cm ) Standard up to DN 8 (/6 in.) >= μs/cm, > DN 8 (/6 in.) >= μs/cm and cable length max. m (66 ft) ) Option: Up to DN 8 (/6 in.) >= µs/cm, > DN 8 (/6 in.) >=. µs/cm and cable length max. m (66 ft) ) For application e.g. with high fat contents

Electromagnetic Flowmeter FSM D8S7U Main order number Add. order no. Version number 6 7 8 9 6 7 8 9 6 7 8 XX Electromagnetic Flowmeter SE- X X X X X X X X X X X X X X X X X X X X X X X XX FSM Gasket Material Without A EPDM (with FDA certificate) E Silicone (with FDA certificate) S PTFE ) T Viton ) V Signal Cable Length Without cable m (6 ft) m ( ft) m (66 ft) m ( ft) m ( ft) m (6 ft) 6 m (97 ft) 6 7 m ( ft) 7 8 m (6 ft) 8 9 m (9 ft) 9 m (8 ft) m ( ft) m (9 ft) 7 m (7 ft) 7 m (66 ft) Excitation Cable Length Without cable m (6 ft) m ( ft) m (66 ft) m ( ft) m ( ft) m (6 ft) 6 m (97 ft) 6 7 m ( ft) 7 8 m (6 ft) 8 9 m (9 ft) 9 m (8 ft) m ( ft) m (9 ft) 7 m (7 ft) 7 m (66 ft) Continued on next page ) DN... DN (/... / in.) ) Only DN... DN (/... / in.) and PVC process connection

Electromagnetic Flowmeter FSM D8S7U Main order number Add. order no. Version number 6 7 8 9 6 7 8 9 6 7 8 XX Electromagnetic Flowmeter FSM SE- X X X X X X X X X X X X X X X X X X X X X X X XX Calibration points (standard) VK point standard calibration VC Witnessed calibration, calibration points 6) VE point calibration acc. DAkkS 6) VD Language of Documentation German M English M Russian MB Language package Western Europe / Scandinavia (Languages: DE, EN, DA, ES, FR, IT, NL, PT, FI, SV) MW Language package Eastern Europe (Languages: DE, EL, CS, ET, LV, LT, HU, PL, SK, SL, RO, BG) ME Others MZ Other Usage Certifications Russia - metrological and GOST-R certificate CG Kazakhstan - metrological and GOST-K certificate CG Ukraine - metrological certificate CG Belarus - Metrological Certificate CG6 Lay Length Old length for DN - JE New length for DN 6, DN 8, DN JF 6) Only available with FSM-S External Converter

Electromagnetic Flowmeter FSM D8S7U Mounting accessories Change from one to two columns Wafer type accessories The following accessories are available based on meter size and pressure rating: Bolts, nuts, lockwashers. Gaskets are not included in the accessories. For order information, see page. Weld connections For flowmeters with welded connections, welding adapters are available. For order information, see page.

Electromagnetic Flowmeter FSM D8S7U Change from one to two columns. Ordering information Wafer type Accessories (Table H) Wafer type Accessories Description Nominal size Nominal pressure rating Order number FX / FSM Wafer type Accessories DN... DN (/... /8 in.) PN... PN D6L6U ASME CL D6L6U ASME CL D6L6U Welding adapter DN (/ in.) PN... PN D6L6U ASME CL D6L66U ASME CL D6L66U6 DN (/ in.) PN... PN D6L67U ASME CL D6L67U ASME CL D6L67U6 DN ( in.) PN... PN D6L68U ASME CL D6L68U ASME CL D6L68U6 DN (-/ in.) PN... PN D6L69U ASME CL D6L69U ASME CL D6L69U6 DN (-/ in.) PN... PN D6L7U ASME CL D6L7U ASME CL D6L7U6 DN ( in.) PN... PN D6L96U ASME CL D6L96U ASME CL D6L96U6 DN 6 (-/ in.) PN... PN 6 D6L97U8 PN... PN D6L97U9 ASME CL D6L97U ASME CL D6L97U DN 8 ( in.) PN... PN D6L98U8 ASME CL D6L98U9 ASME CL D6L98U DN ( in.) PN... PN 6 D6L99U7 PN... PN D6L99U8 ASME CL D6L99U9 Material Nominal size Order number Stainless steel AISI (.) DN... DN (/... /8 in.) DC7U DN (/ in.) DC7U DN (/ in.) DC7U DN ( in.) DN (-/ in.) DN (-/ in.) DN ( in.) DN 6 (-/ in.) DN 8 ( in.) DN ( in) DC7U DC7U DC7U DC88U DC6U9 DC96U DC98U The adapter is a tool for sensors that feature weld stubs as the process connection type. It enables these weld stubs to be welded into the pipeline in a coplanar manner.

Change from one to two columns Electromagnetic Flowmeter FSM D8S7U 6 Transmitter 6. Specifications Design Field-mount housing made of cast aluminum per DIN 7, painted. Paint coat thickness 8 µm. Lower section (RAL 7), upper section (RAL 9). See dimensions on page 66. Weight, approx.. kg. Electrical connections Cable entry M x., NPT, PF with adapter (upon request), screw terminals Damping ( ) Configurable for.7... s. Fig. 7: Transmitter FSM-S Measuring range Minimum conductivity Repeatability (measurement period = s) Response time Supply power Power consumption Ambient temperature Storage temperature G8 Any flow range whose % value corresponds to a flow velocity between. m/s and m/s can be selected. µs/cm standard µs/cm with preamplifier µs/cm with preamplifier. µs/cm with preamplifier DN... (/8... ) DN... 8 (/... /6 ) DN... (/... ) DN... (/8... ) DN... (/... /"): ± (. % of measured value +. % of Q maxdn ) DN... (/... "): ± (. % of measured value +. % of Q maxdn ) = 7 ms (... 66 %) "Fast" mode = ms (... 66 %) "Standard" mode/piston pump U =... V, / 6 Hz U rat = 8... V, / 6 Hz /6 Hz ± 6%.... 6. V AC,..... V DC, ripple % S VA (flowmeter sensor including transmitter) -... 6 C (-... F) -... 8 C (-... 76 F) Relative humidity Acc. to IEC 668-- classification of environmental conditions, natural factors, temperature and air humidity. No effect under the following conditions: Temperature in range from... C (77... F) and a relative humidity of 9... 97%. Vibration Acc. to IEC 668--6 (/9), grouping of devices according to table C for general industry applications. No additional effect on the following levels of vibration. Frequency:... Hz; amplitude max.. mm. Low flow cutoff Configurable for... % of end value range Signal cable Max. cable length between flowmeter sensor and transmitter is: m for the standard design and versions with automatic zero return, from DN (/8") and from µs/cm. m for designs with preamplifier. A m signal cable is included with each flowmeter. If a longer cable is required, see the order information for the flowmeter sensor on page, 6. Magnet coil supply cable Is required to connect the flowmeter sensor to the transmitter. For EMC reasons, the -wire cable is shielded. A m cable is included with each flowmeter. If a longer cable is required, see the order information for the flowmeter sensor on page, 6. Forward/reverse flow metering Flow direction is indicated by direction arrows in the display and over the contact for external signaling. The contact output can also transmit this information. Display -line, illuminated graphic display. To improve readability, the flow information can be displayed on two lines with larger characters. This allows the individual flowrate and output values to be displayed. Nonswitching dot-matrix display with max. x 6 characters. A plaintext diagnostic display opens automatically when the system detects an error. An alarm condition can also be signaled via contact output. Data backup Via FRAM (ferroelectric non-volatile random access memory) all data is stored for a period of years (even without supply power) at shutoff or during a power outage. Additional security is provided by a serial FRAM installed in the transmitter and on the external connection board in which the parameter settings and process information are stored. This makes it easy to replace a transmitter without reconfiguration by simply uploading the stored data from the external FRAM to the new transmitter. Flow totalization The flow is totalized in engineering units. The limits for the pulse factor are configurable and depend on the measuring range (Qmax) as well as the totalizer units selected. The limits are a min. (.6 Hz) and max. pulse frequency ( KHz). Totalizer values for the forward and reverse flow directions can be displayed simultaneously by selecting the "Display" menu item. Degree of protection acc. to EN 69 IP 67 for field-mount housing and NEMA X

Electromagnetic Flowmeter FSM D8S7U Parameter adjustment The display supports several languages (German, English, French, Finnish, Swedish, Italian, Spanish, Dutch or Turkish), and information can be entered using the three keys in the dialog or via a communication interface with PC, HART protocol, PROFIBUS or FOUNDATION Fieldbus. The magnet stick can also be used to configure the flowmeter with the front door closed. Position the magnet stick over the magnet icons on the display cover. Alarm signals A max-min alarm can be used with the transmitter. The alarm limits can be set between... % of the flow range. When the flowrate is outside the alarm limits, an error message is displayed in the upper line and a contact is triggered. The contact output can also transmit this information. Wiring error Monitoring of magnet coil or electrode circuits for short circuits or wire breaks. Upgrades The transmitter with all its functions can also be used with older model electromagnetic flowmeters. The appropriate model number must be selected during parameter setting of the transmitter. It is also possible to use the transmitter with model D flowmeters. A special FRAM (Cs = %, Cz = %) is required when updating an older model (see order information for transmitter) and applies for meter sizes DN... DN (/... ") in low voltage design only. Isolation of input/output The current output, pulse output, contact input and contact output are electrically isolated from the input circuit and from each other. Extended diagnostic functions Recorded parameters/fingerprints Cyclical ( s... 7 days) or manual acquisition of parameters. The data records are stored in the transmitter FRAM (with time stamp / operating hours counter). A maximum of records can be stored. When the eleventh record is stored, the oldest data record is overwritten automatically. Magnet coil circuit Electrode circuit AC voltage AC DC resistance (primary value for temperature) Temperature Insulation resistance (ground) DAC value (primary value for coil current) Magnetic linearity Electrode voltage E (primary value for electrode balance) Electrode voltage E (primary value for electrode balance) Electrode balance Quality (signal-to-noise ratio) The parameters can be checked for min.-max. errors. If the value is above or below the specified limit, a diagnostic error or warning, depending on the configuration, is triggered. The fingerprint database integrated in the transmitter allows you to compare the values at the time of factory calibration or commissioning with the currently recorded values. Users can store up to three different fingerprint data records (commissioning, product, product) in the fingerprint database. The default fingerprint (optional) cannot be overwritten. Detectable error states Monitoring of... Detection of... Coil current / coil Changes in the driver or coil circuit. voltage / DAC value Coil resistance Coil temperature Coil insulation resistance Linearity of magnetic circuit Signal quality (signalto-noise ratio) Electrode balance Changes in coil circuit, e.g., fine short. Risk of overheating due to fluid. Problems with the coil insulation. Can be caused, e.g., by dampness in the flowmeter sensor or in the connection box. External magn. field interference on the EMF, resulting in loss of accuracy. Changes in fluid, e.g., gas bubbles, increased / reduced amount of solids. Distorted flow profile, e.g., due to improper installation. Detect interference in electrode circuit, e.g., failure of electrode due to insulating coating or a collapsed liner (vacuum shock). Backward compatibility The transmitter is suitable for connecting to flowmeter sensors over years old. Occasionally, an adapter board may be required (for details, see the FSM operating instructions). The following flowmeter sensors are supported: DS, DSF, DSF, DS (A-E), DI, D, D6, D7 6

Electromagnetic Flowmeter FSM D8S7U 6. Inputs/outputs DC output (terminals, ) The following functions can be selected in the software:... ma load 6 Ω... ma load 6 Ω... ma load Ω... ma load Ω 6. Digital communication The transmitter has the following options for digital communication: 6.. HART protocol The unit is registered with the HART Communication Foundation. Contact output (terminals, ) The following functions can be selected in the software: Forward/reverse flow direction signal Flowrate alarm (max. or min.) General alarm Empty pipe The contact output can be configured as normally open or normally closed. Optocoupler "closed" "open" V U CEL V, ma I CEL ma 6 V U CEH V, ma I CEH ma Scaled pulse output (terminals, ) Maximum totalizer frequency khz. Pulse factor per engineering unit from.... / unit selectable in the software. The pulse width is configurable from.... The version (active, passive) can be changed via jumpers. Active Voltage pulse V rectangular Load Ω Pulse width ms, max. pulse frequency Hz, Load Ω Pulse width. ms, max. pulse frequency: khz. Passive Optocoupler "closed": "open": V U CEL V, ma I CEL ma 6 V U CEH V, ma I CEH ma Contact input (terminals 8/8) Passive based on normally open contact (closed). The following functions can be selected in the software: External output signal switch-off When the meter tube empties the output signals can be turned off. DC output, e.g., ma or / ma, depending on current output configuration. External totalizer reset For totalizer overflows displayed internally and pulse counters for both flow directions. External system zero position Starts the external zero adjustment. To run a zero adjustment, the metering tube must be full and flowrate must be zero. The adjustment lasts approx. minute. Design passive (optocoupler) "ON": 6 V U KL V "OFF" V U KL V Ri: kω Fig. 8 HART protocol Configuration Transmission Max. signal amplitude Current output load Cable Max. cable length Baud rate Directly on the device Software DAT Asset Vision Basic (+ HART-DTM) FSK modulation on current output... ma acc. to Bell standard. ma ss Min. Ω, max. = 6 Ω AWG twisted m baud Display Log. : Hz Log. : Hz For additional information, see the separate interface description. System integration In conjunction with the DTM (Device Type Manager) available for the device (software version B. and higher), communication (configuration, parameterization) can occur with the corresponding framework applications according to FDT. (DAT Asset Vision Basic). Other tool/system integrations (e.g., Emerson AMS/Siemens S7) are available upon request. A free of charge version of the DAT Asset Vision Basic framework application for HART or PROFIBUS is available upon request. The required DTMs are contained on the DAT Asset Vision Basic DVD or in the DTM Library. They can also be downloaded from www.abb.com/flow. 6.. PROFIBUS PA protocol The interface conforms to Profile. (PROFIBUS standard, EN 7, DIN 9 [PRO9]). PROFIBUS PA ID no.: x78c Alternative standard ID no.: x97 or x97 Configuration Directly on the device Software DAT Asset Vision Basic (+ PROFIBUS PA-DTM) Transmission signal Acc. to IEC 68- Cable Shielded, twisted cable (acc. to IEC 68-, types A or B are preferred) 7

Electromagnetic Flowmeter FSM D8S7U PROFIBUS DP PROFIBUS PA H-Bus A PA+ PA- PA+ PA- PA+ PA- A = Segment coupler (incl. bus supply and termination) Fig. 9: Example for PROFIBUS PA interface connection F G 6.. FOUNDATION Fieldbus (FF) FF interface Compliant with FF standard 89/89 and FF 9/9 Interoperability test IT 7 (ITK.6) campaign no. Manufacturer ID Device ID x x7 Configuration Directly on the device Via services integrated in the system National configurator Transmission signal Acc. to IEC 68- Bus topology Tree and / or line structure Bus termination: passive at both ends of the main bus line (RC element R = Ω, C = µf) Voltage / current consumption Average current consumption: ma In the event of an error, the integrated FDE function (=Fault Disconnection Electronic) integrated in the device is ensures that the current consumption can rise to a maximum of ma. The upper current limit is restricted electronically. The voltage on the bus line must lie in the range of 9... V DC. Bus address In the case of devices with a PROFIBUS PA interface, check the bus address prior to commissioning. If no specifications exist to the contrary, the address is set to 6. During commissioning, the address must be set to a valid value in the range.... System integration Use of PROFIBUS PA profile B, B. ensures interoperability and interchangeability of units. Interoperability means that devices from different manufacturers can be physically connected to a bus and are communication-ready. The devices can be interchanged without having to reconfigure the process control system. To support interchangeability, three different GSD files (equipment master data) are provided, which can be integrated in the system. For additional information, see the separate interface description. The manufacturer-specific GSD file ABB_78C can be downloaded from http://www.abb.com/flow. The standard GSD files PA97xx.gsd can be downloaded from http://www.profibus.com. Ethernet HSE-Bus B FOUNDATION fieldbus H FF+ FF- FF+ FF- FF+ FF- B = Linking device (incl. bus supply and termination) Fig. : F G Example for FOUNDATION Fieldbus interface connection Bus topology Tree and / or line structure Bus termination: passive at both ends of the main bus line (RC element R = Ω, C = µf) Voltage / current consumption Average current consumption: ma In the event of an error, the integrated FDE function (=Fault Disconnection Electronic) integrated in the device is ensures that the current consumption can rise to a maximum of ma. Upper current limit: electronically restricted. The voltage on the bus line must lie in the range of 9... V DC. Bus address The bus address is automatically assigned or can be set in the system manually. Addresses are detected using a unique combination of manufacturer ID, device ID, and device serial number. System integration The following are required: DD (Device Description) file, which includes the device description. The CFF (Common File Format) file is required for engineering the segment. Engineering can be performed online or offline. For additional information, see the separate interface description. The files required for operation can be downloaded from http://www.fieldbus.org. 8

Electromagnetic Flowmeter FSM D8S7U Change from one to two columns 6. Electrical connections Standard DN... DN (/8... ") S transmitter (wall mount housing) S S 6 6 7 8 8 M M - + N L 8 9 6 7 SE S S A 6 M M SE Flowmeter sensor G9 Fig. : Connection diagram: Flowmeter sensor standard DN... DN (/8... ") Functional ground (busbar) Pulse output ) Contact input ) Contact output ) Current output ) 6 Magnet coil cable: shielded x mm CE Typ 7 TEC 7 ABB order no. D7D7U, m included in shipment, standard 7 Supply power Low voltage:... V AC, terminals L, N, Low voltage:....6. V AC; Low voltage:..... V DC Low voltage: Terminals +, -, Frequency: 7 Hz f Hz; Hz supply power Frequency: 6 Hz f 6 Hz; 6 Hz supply power 8 Steel shielding 9 Aluminum foil Yellow Shield Blue Red White Shielded signal cable: ABB order no. D7DU, m included in shipment ) See the section "Connection examples for peripherals" in the operating instructions and/or on the data sheet Comment: We recommend that shielded output cables be used with the shields connected to the functional ground at one end. 9

Electromagnetic Flowmeter FSM D8S7U with preamplifier DN... DN (/... ") S transmitter (wall mount housing) U+ U- 6 6 7 8 8 M M - + N L 8 9 6 7 6 SE U+ U- A 6 M M SE Flowmeter sensor G96 Fig. : Connection diagram: Flowmeter sensor with preamplifier DN... DN (/... "), transmitter field-mount housing Functional ground (busbar) Pulse output ) Contact input ) Contact output ) Current output ) 6 Magnet coil cable: shielded x mm CE Typ 7 TEC 7 ABB order no. D7D7U, m included in shipment, standard 7 Supply power Low voltage:... V AC, terminals L, N, Low voltage:....6. V AC; Low voltage:..... V DC Low voltage: Terminals +, -, Frequency: 7 Hz f Hz; Hz supply power Frequency: 6 Hz f 6 Hz; 6 Hz supply power 8 Steel shielding 9 Aluminum foil Yellow Shield Blue Red White Shielded signal cable: ABB order no. D7DU, m, included in shipment 6 With preamplifier (always with DN... DN 8 [/... /6"]) ) See the section "Connection examples for peripherals" in the operating instructions and/or on the data sheet Comment: We recommend that shielded output cables be used with the shields connected to the functional ground at one end. Important If the flowmeter sensor is equipped with a preamplifier for low conductivity or in nominal diameter DN... DN 8 (/... /6"), the shieldings of the signal wires must be connected to terminals U+ and U- on both the flowmeter sensor and the transmitter. 6

Electromagnetic Flowmeter FSM D8S7U Retrofitting for model D: DN... DN (/... ); model DI and DSA-E: DN... DN (... ) S transmitter (wall mount housing) 8 V S S 6 6 7 8 8 M M N L 7 6 9 SE 6 7 L N Flowmeter sensor G Fig. : Flowmeter sensor standard DN... DN (/... "), transmitter field-mount housing Functional ground (busbar) Pulse output ) Contact input ) Contact output ) Current output ) 6 Supply power Low voltage:... V AC, terminals L, N, Frequency: 7 Hz f Hz; Hz supply power Frequency: 6 Hz f 6 Hz; 6 Hz supply power 7 Shielded signal cable: Use ABB order no. D7DU or incorporate in existing wiring 8 Reference cable: Only for connection to model D Terminals: close 6,7 and the hook switch S9 9 Magnet coil supply: Magnet coil supply via supply power Connection board: D68AU ) See the section "Connection examples" in the operating instructions and/or on the data sheet Comment: We recommend that shielded output cables be used with the shields connected to the functional ground at one end. 6

Electromagnetic Flowmeter FSM D8S7U DN... DN (/... ") with PROFIBUS PA / FOUNDATION Fieldbus S transmitter (wall mount housing) 6 6 c b FF+ FF- U+ U- PA+ PA- a S S 6 97 98 M M - + N L 7 8 9 SE S S A 6 M M SE SE U+ U- A 6 Flowmeter sensor M M SE 6 G97 Fig. : Connection diagram: transmitter SF with PROFIBUS PA / FOUNDATION Fieldbus Functional ground (busbar) Supply power Contact output (see the section "Connection examples for peripherals" in the operating instructions and/or on the data sheet) Low voltage:... V AC, terminals L, N, Low voltage:....6. V AC; Low voltage:..... V DC Digital communication Low voltage: Terminals +, -, a: PROFIBUS PA design according to IEC 68- (Profile Frequency: 7 Hz f Hz; Hz supply power.) Frequency: 6 Hz f 6 Hz; 6 Hz supply power a: U = 9... V, I = ma (normal operation) 6 Shielded signal cable: a: U = 9... V, I = ma (in the event of error/fde) Power supply for flowmeter sensor with preamplifier a: Terminals: 97/98, PA+/PA- Terminals U+, U- instead of S and S in standard unit a: (see the section "Connecting via M plug" in the operating 7 Steel shielding a: instructions and/or on the data sheet) 8 Aluminum foil b: FOUNDATION Fieldbus design conforming to IEC 68-9 Yellow a: U = 9... V, I = ma (normal operation) Shield a: U = 9... V, I = ma (in the event of error/fde) Blue a: Terminals: 97/98, FF+/FF- Red a: (see the section "Connecting via M plug" in the operating White a: instructions and/or on the data sheet) Shielded signal cable: ABB order no. D7DU, c: Bus termination with installed bus termination m, included in shipment a: components with hook switches closed Without preamplifier Magnet coil cable: 6 With preamplifier (always with DN... DN 8 [/... /6"]) shielded x mm CE Typ 7 TEC 7 ABB order no. D7D7U, m included in shipment, standard Comment: We recommend that shielded output cables be used with the shields connected to the functional ground at one end. Important If the flowmeter sensor is equipped with a preamplifier for low conductivity or in nominal diameter DN... DN 8 (/... /6"), the shieldings of the signal wires must be connected to terminals U+ and U- on both the flowmeter sensor and the transmitter. 6

Electromagnetic Flowmeter FSM D8S7U 6. Connection examples for peripherals (incl. HART) Current output /... ma /... ma I E I = internal E = external + - Current output: Function: G selectable in software Active /... ma ( Ω RB 6 Ω) /... ma ( Ω RB Ω) (with HART only... ma) Terminals:, Fig. : Current output active with/without HART protocol (... ma) Contact output I E +U R B * V VDC Note Horn and alarm light are shown only as examples. Other suitable devices such as bells, sirens, buzzers, etc., can also be used. * U R CE B I CE G Contact output: Function: selectable in software Passive "closed" V U CEL V, ma I CEL ma "open" 6 V U CEH V, ma I CEH ma Terminals:, Fig. 6: Contact output for system monitoring, Max.-Min. alarm for empty tube or forward/reverse signal Contact input I E R i 8 8 + 6... V DC V G Contact input: Function: selectable in software Passive "On" 6 V U KL V "Off" V U KL V Ri = kω Terminals: 8, 8 Fig. 7: Contact input for external totalizer reset and external zero return 6

Electromagnetic Flowmeter FSM D8S7U Pulse output Pulse output active Pulse output, passive, optocoupler I E R * B + 6... V DC - * R B U CE I CE G7 Function: fmax: fmin: Setting range: active/passive, selectable via jumper (see "Commissioning" in operating instructions) khz,.6 Hz Pulses/unit, pulse width (observe dynamic limits) Active: Ω Load < kω Pulse width ms, max. pulse frequency Hz, Ω Load < kω Pulse width. ms, max. pulse frequency: khz Passive: Terminals:, Fig. 8: "closed": V UC EL V, ma I CEL ma "open": 6 V U CEH V, ma I CEH ma Pulse output, active and passive, optocoupler PROFIBUS PA / FOUNDATION Fieldbus I E I E The resistance R and capacitor C form the bus termination. They must be installed when the device is connected to the end of the PA- FF- entire bus cable. 98 98 R = Ω; C = µf R R PA+ FF+ PROFIBUS PA C C 97 97 FOUNDATION Fieldbus I = Internal G8 E = external Fig. 9 6

Electromagnetic Flowmeter FSM D8S7U Bus termination for S transmitter To terminate the bus if the instrument is at the end of the bus cable, the termination components in the S transmitter can be used. To do so, close both hook switches in the connection area of the transmitter. Important If the transmitter plug-in module is removed, bus termination is also canceled. U+ S S U- 6 6 7 97 98 M M Connection board for field housing unit Hook switches for bus termination must be closed G9 Fig. Connection via M plug (for PROFIBUS PA only) As an option, the bus can also be connected via an M plug instead of the cable gland (see order information for device). The device can be shipped completely prewired. For information about suitable connectors (type EPG) and other accessories, refer to the data sheet /6.6. DE. Pin assignment (Front view showing pin insert and pins) PIN = PA+ PIN = nc PIN = PA- PIN = shield G Fig. 6

Electromagnetic Flowmeter FSM D8S7U 6.6 Dimensions 6.6. Transmitter housing and mounting arrangements (.9) 98 (7.79) 9,7 (.) 67 (6.7) Ø7 (.7), (.7) 6 (.) 9 (9.8) 66 (.9) 8 (.9) (.9) 8, (.8) M x, min. 6 (.) min.7 (6.88) G7 Fig. : (Dimensions in mm) Field mount housing with window Cable connector M x. Mounting holes for pipe mounting set for a pipe installation; mounting set upon request (order no. 6B9U7) Protection class IP 67 66

Electromagnetic Flowmeter FSM D8S7U 6.7 Ordering information Accuracy.% of rate, for FSM-SE / -SE Main order number Add. order no. Version number 6 7 8 9 XX FSM-S External Converter S- X X X X X X X X X X X XX Housing Field housing (cable gland M x.) A Field housing (cable gland / in. NPT) B Power Supply... V AC G 6.8... 6. V AC / 6.8.... V DC K Display Magnetic stick operation and display illuminated A Input / Output Options Current output active + Pulse output active + ) Contact input + Contact output Current output active + Pulse output active + Contact input + Contact output + HART Current output active + Pulse output passive + ) Contact input + Contact output Current output active + Pulse output passive + Contact input + Contact output + HART Contact output + PROFIBUS PA 7 Contact output + FOUNDATION Fieldbus 8 Contact output + PROFIBUS PA with M plug Others 9 9 Application Extended diagnostics For Flowmeter Sensor SE_, SE_ ) DS_, DS_, DS, DI (>= DN ) [ in.]), D, D8, D Certificates Standard Name Plate Language / Type German / Adhesive foil G English / Adhesive foil E French / Adhesive foil F German / Stainless steel J English / Stainless steel K French / Stainless steel L Design Level / Software Level (Specified by ABB) X X Language of Documentation German English Russian Language package Western Europe / Scandinavia (Languages: DE, EN, DA, ES, FR, IT, NL, PT, FI, SV) Language package Eastern Europe (Languages: DE, EL, CS, ET, LV, LT, HU, PL, SK, SL, RO, BG) Others Other Usage Certifications Russia - metrological and GOST-R certificate Kazakhstan - metrological and GOST-K certificate Ukraine - metrological certificate Belarus - metrological certificate M M MB MW ME MZ CG CG CG CG6 ) Not with low voltage power supply (code K) ) The external FRAM is in the terminal box of the associated flowmeter sensor on delivery ) In this variant, the external FRAM already is plugged into the converter with the values Cz = % and Cs = %. 67

Electromagnetic Flowmeter FSM D8S7U 6.8 Flowmeter sensor simulator - FXC Flowmeter sensor simulator, for transmitter types FXE- E, FXM-XM, FXF-DF, FES7-ES7, FSM-S, FET Main order number Version number 6 7 8 9 XC X X X X X Flow Signal Setting Without (adapter only) -position digitswitch with steps Power Supply Without (adapter only)... V AC / 6 Hz // With Schuko plug... 8 V AC / DC // With mm plug... V AC / 6 Hz // With US plug Accessories Without Adapter for converter type FXE-E, FXM-XM, FXF-DF Adapter board for converter type FSM-S Adapter plate for converter FET 6 Design level (specified by ABB) * Name Plate German English French 6.9 Installation set for " pipe installation in field-mount housing Abb. : Part number: KXF8L G789 68