FLASH X-RAY (FXR) ACCELERATOR OPTIMIZATION INJECTOR VOLTAGE-VARIATION COMPENSATION VIA BEAM-INDUCED GAP VOLTAGE *

Similar documents
FLASH X-RAY (FXR) ACCELERATOR OPTIMIZATION BEAM-INDUCED VOLTAGE SIMULATION AND TDR MEASUREMENTS *

TRANSMISSION LINE AND ELECTROMAGNETIC MODELS OF THE MYKONOS-2 ACCELERATOR*

ANALYSIS OF SWITCH PERFORMANCE ON THE MERCURY PULSED- POWER GENERATOR *

A NEW BROADBAND PULSED HIGH VOLTAGE MONITOR *

PULSED POWER SWITCHING OF 4H-SIC VERTICAL D-MOSFET AND DEVICE CHARACTERIZATION

Investigation of a Forward Looking Conformal Broadband Antenna for Airborne Wide Area Surveillance

MEASUREMENTS OF THE RADIATED FIELDS AND CONDUCTED CURRENT LEAKAGE FROM THE PULSED POWER SYSTEMS IN THE NATIONAL IGNITION FACILITY AT LLNL

ANALYSIS OF A PULSED CORONA CIRCUIT

RAVEN, A 5 kj, 1.5 MV REPETITIVE PULSER* G. J. Rohwein Sandia National Laboratories Albuquerque, New Mexico 87185

An experimental system was constructed in which

DEVELOPMENT OF AN ULTRA-COMPACT EXPLOSIVELY DRIVEN MAGNETIC FLUX COMPRESSION GENERATOR SYSTEM

PULSED BREAKDOWN CHARACTERISTICS OF HELIUM IN PARTIAL VACUUM IN KHZ RANGE

David L. Lockwood. Ralph I. McNall Jr., Richard F. Whitbeck Thermal Technology Laboratory, Inc., Buffalo, N.Y.

Modeling Antennas on Automobiles in the VHF and UHF Frequency Bands, Comparisons of Predictions and Measurements

IB2-1 HIGH AVERAGE POWER TESTS OF A CROSSED-FIELD CLOSING SWITCH>:< Robin J. Harvey and Robert W. Holly

PHASING CAPABILITY. Abstract ARRAY. level. up to. to 12 GW. device s outpu antenna array. Electric Mode. same physical dimensions.

DEVELOPMENT OF STITCH SUPER-GTOS FOR PULSED POWER

8.2. Washington, D. C delivered 65 kj into a matched load with 63 ns FWHM. Peak power was about 1 TW.

9.4 A HIGH CURRENT PULSER FOR EXPERIMENT 11225, "NEUTRINO ELECTRON ELASTIC SCATTERING" C. Dalton, G. Krausse, and J. Sarjeant

Modeling of Ionospheric Refraction of UHF Radar Signals at High Latitudes

Signal Processing Architectures for Ultra-Wideband Wide-Angle Synthetic Aperture Radar Applications

PERFORMANCE OF A 10 KV, 625 KA, 85 KJ ENERGY DISCHARGE MODULE UTILIZING A SOLID DIELECTRIC SWITCH.*

Strategic Technical Baselines for UK Nuclear Clean-up Programmes. Presented by Brian Ensor Strategy and Engineering Manager NDA

Lattice Spacing Effect on Scan Loss for Bat-Wing Phased Array Antennas

SILICON CARBIDE FOR NEXT GENERATION VEHICULAR POWER CONVERTERS. John Kajs SAIC August UNCLASSIFIED: Dist A. Approved for public release

Adaptation of ASTERIX to Positive Polarity for 2 to 4-MV Rod-Pinch Diode Experiments and Diode Electrical Analysis *

0.18 μm CMOS Fully Differential CTIA for a 32x16 ROIC for 3D Ladar Imaging Systems

EFFECT OF TRANSFORMER LEAKAGE INDUCTANCE ON THE THREE PHASE CAPACITIVE INPUT RECTIFIER

D. M. Barrett University of California Lawrence Livermore National Laboratory Livermore, CA (b) PFL Voltage at Point A. (c) Voltage Across Load

ACCELERATOR FAST KICKER R&D WITH ULTRA COMPACT 50MVA NANO-SECOND FID PULSE GENERATOR

"OPTIMAL SIMULATION TECHNIQUES FOR DISTRIBUTED ENERGY STORE RAILGUNS WITH SOLID STATE SWITCHES"

A COMPACT, 1-MV, 6-kA RADIOGRAPHY SOURCE WITH A ONE- METER EXTENSION AND RIGHT-ANGLE BEND

A RENEWED SPIRIT OF DISCOVERY

INVESTIGATION OF A HIGH VOLTAGE, HIGH FREQUENCY POWER CONDITIONING SYSTEM FOR USE WITH FLUX COMPRESSION GENERATORS

EVALUATION OF RESISTORS FOR TRANSIENT HIGH-VOLTAGE APPLICATIONS

CFDTD Solution For Large Waveguide Slot Arrays

Active Denial Array. Directed Energy. Technology, Modeling, and Assessment

EFFECTS OF ELECTROMAGNETIC PULSES ON A MULTILAYERED SYSTEM

Design of Synchronization Sequences in a MIMO Demonstration System 1

OPTICAL EMISSION CHARACTERISTICS OF HELIUM BREAKDOWN AT PARTIAL VACUUM FOR POINT TO PLANE GEOMETRY

ANALYSIS OF WINDSCREEN DEGRADATION ON ACOUSTIC DATA

UPGRADES TO THE DARHT SECOND AXIS INDUCTION CELLS

Best Practices for Technology Transition. Technology Maturity Conference September 12, 2007

Remote Sediment Property From Chirp Data Collected During ASIAEX

Two-Way Time Transfer Modem

INDUCTIVE VOLTAGE ADDER NETWORK ANALYSIS AND MODEL SIMPLIFICATION

Durable Aircraft. February 7, 2011

Report Documentation Page

Loop-Dipole Antenna Modeling using the FEKO code

L. B. Gordon Space Power Institute 231 Leach Center Auburn University, Alabama 36849

Solar Radar Experiments

PSEUDO-RANDOM CODE CORRELATOR TIMING ERRORS DUE TO MULTIPLE REFLECTIONS IN TRANSMISSION LINES

DIELECTRIC ROTMAN LENS ALTERNATIVES FOR BROADBAND MULTIPLE BEAM ANTENNAS IN MULTI-FUNCTION RF APPLICATIONS. O. Kilic U.S. Army Research Laboratory

Report Documentation Page

COM DEV AIS Initiative. TEXAS II Meeting September 03, 2008 Ian D Souza

CHARACTERIZATION OF PASCHEN CURVE ANOMOLIES AT HIGH P*D VALUES

SURFACE WAVE SIMULATION AND PROCESSING WITH MATSEIS

W. L. Bird University of Texas, Austin, Center for Electro-Mechanics, Taylor Hall 167, Austin, TX 78712

** Present Address: Maxwell Technologies, San Diego, CA CONDUCTION TIME/CURRENT LIMITATION ON THE DEFENSE SPECIAL WEAPONS AGENCY DECADE MODULE 1*

IREAP. MURI 2001 Review. John Rodgers, T. M. Firestone,V. L. Granatstein, M. Walter

Robotics and Artificial Intelligence. Rodney Brooks Director, MIT Computer Science and Artificial Intelligence Laboratory CTO, irobot Corp

REPORT DOCUMENTATION PAGE

A Comparison of Two Computational Technologies for Digital Pulse Compression

J, 1. lj, f J_ Switch DESIGN OF A PULSED-CURRENT SOURCE FOR THE INJECTION-KICKER MAGNET AT THE LOS ALAMOS NEUTRON SCATTERING CENTER ABSTRACT

Coherent distributed radar for highresolution

Advances in SiC Power Technology

SA Joint USN/USMC Spectrum Conference. Gerry Fitzgerald. Organization: G036 Project: 0710V250-A1

THE DET CURVE IN ASSESSMENT OF DETECTION TASK PERFORMANCE

EVALUATION OF COMMERCIALLY AVAILABLE IGNITRONS AS HIGH-CURRENT, HIGH-COULOMB TRANSFER SWITCHES*

2008 Monitoring Research Review: Ground-Based Nuclear Explosion Monitoring Technologies INFRAMONITOR: A TOOL FOR REGIONAL INFRASOUND MONITORING

August 9, Attached please find the progress report for ONR Contract N C-0230 for the period of January 20, 2015 to April 19, 2015.

A PC-BASED TIME INTERVAL COUNTER WITH 200 PS RESOLUTION

Development of a charged-particle accumulator using an RF confinement method FA

EVAUATION OF THE ROD-PINCH DIODE AS A HIGH-RESOLUTION SOURCE FOR FLASHRADIOGRAPHY AT 2 TO 4 MV *

COMPACT FLASH X-RAY UNITS. Abstract

Adaptive CFAR Performance Prediction in an Uncertain Environment

SYSTEMATIC EFFECTS IN GPS AND WAAS TIME TRANSFERS

Reduced Power Laser Designation Systems

David Siegel Masters Student University of Cincinnati. IAB 17, May 5 7, 2009 Ford & UM

REGULATED CAPACITOR CHARGING CIRCUIT USING A HIGH REACTANCE TRANSFORMER 1

UNCLASSIFIED UNCLASSIFIED 1

STABILITY AND ACCURACY OF THE REALIZATION OF TIME SCALE IN SINGAPORE

INTEGRATIVE MIGRATORY BIRD MANAGEMENT ON MILITARY BASES: THE ROLE OF RADAR ORNITHOLOGY

Experimental Observation of RF Radiation Generated by an Explosively Driven Voltage Generator

Innovative 3D Visualization of Electro-optic Data for MCM

Technology Maturation Planning for the Autonomous Approach and Landing Capability (AALC) Program

D.V.Giri, Pr<r Tech, 1630 North Main Street, #377 Walnut Creek, California and L A REALISTIC ANALYTICAL MODEL FOR THE PULSER

GLOBAL POSITIONING SYSTEM SHIPBORNE REFERENCE SYSTEM

The Energy Spectrum of Accelerated Electrons from Waveplasma Interactions in the Ionosphere

MINIATURIZED ANTENNAS FOR COMPACT SOLDIER COMBAT SYSTEMS

Tracking Moving Ground Targets from Airborne SAR via Keystoning and Multiple Phase Center Interferometry

Acoustic Monitoring of Flow Through the Strait of Gibraltar: Data Analysis and Interpretation

Investigation of Modulated Laser Techniques for Improved Underwater Imaging

Modeling an HF NVIS Towel-Bar Antenna on a Coast Guard Patrol Boat A Comparison of WIPL-D and the Numerical Electromagnetics Code (NEC)

Wavelet Shrinkage and Denoising. Brian Dadson & Lynette Obiero Summer 2009 Undergraduate Research Supported by NSF through MAA

U.S. Army Training and Doctrine Command (TRADOC) Virtual World Project

Evanescent Acoustic Wave Scattering by Targets and Diffraction by Ripples

Social Science: Disciplined Study of the Social World

Hybrid QR Factorization Algorithm for High Performance Computing Architectures. Peter Vouras Naval Research Laboratory Radar Division

DEVELOPMENT OF THE SELF MAGNETIC PINCH DIODE AS A HIGH BRIGHTNESS RADIOGRAPHIC SOURCE

Transcription:

FLASH X-RAY (FXR) ACCELERATOR OPTIMIZATION INJECTOR VOLTAGE-VARIATION COMPENSATION VIA BEAM-INDUCED GAP VOLTAGE * Mike M. Ong Lawrence Livermore National Laboratory, PO Box 88, L-153 Livermore, CA, 94551 Abstract Lawrence Livermore National Laboratory (LLNL) is evaluating design alternatives to improve the voltage regulation in our injector and accelerator cells of our Flash X-Ray (FXR) machine. The operational peak electron beam current and energy at the x-ray generating target are 3.2 ka and 17 MeV. The goal is to create a more mono-energetic electron beam with variation of less than 1%-root-mean-squared (rms). This would allow the beam to be focused more tightly and create an x-ray source with a smaller spot-size. Our injector appears to have significant voltage-variation, and this report describes a technique to appreciably correct the deviations. When an electron beam crosses the energized gap of an accelerator cell, the energy increases. However, the beam with the associated electromagnetic wave also loses a small amount of energy because of the increased impedance seen across each gap. The phenomenon is sometimes called beam loading. It can also be described as a beam-induced voltage at the gap which is time varying. The polarity of this induced voltage is the opposite of the voltage in the injector. The time varying profiles of the injector and induced gap voltage are related through the beam current. However, while the change in magnitude is similar, they are not exactly the same. With the right choice of cell and pulse-power system impedance, the injector variations can be greatly reduced by cancellation, but not totally eliminated. The FXR injector voltage is estimated to be 2.5 MVpeak. The variation is estimated to be about 3.%-rms for an interval of 6 ns. A simplified mathematical explanation of voltage compensation is given, and an idealized injector profile is used to quantify the effectiveness in a computer simulation. The result calls for a constant cell and pulse-power system impedance of 12.1 Ω. For this impedance, the compensated injector voltage-variation is less than.1%-rms. I. FXR ENERGY REGULATION AND INJECTOR VOLTAGE The LLNL FXR is an induction linear accelerator that produces pulsed x-rays and is used regularly and reliably on explosive experiments since its completion in 1982. In recent years, FXR has been incrementally improved, adding double-pulse capability, increasing dose, and reducing x-ray spot-size [1, 2]. FXR generates a 3.2 ka electron beam with 17 MeV of energy. Our present beam duration is 7 ns full-width half-maximum (fwhm). The forward x-ray dose at 1 meter is over 4 Rad, and the current spot-size is about 2 mm-fwhm. The peak energy of the injector is estimated to be 2.5 MeV. Beam energy at the electron to x-ray converter target (eq. 1) is proportionate to the voltage of the injector and accelerator, minus the voltage lost as beam loading [3]. This report focuses on a technique to compensate for injector voltage-variations with the beam-induced voltage in the cells indicated in gray in the equation. E V injector + E V accelerator E V beam-induced = E target (1) This equation has been greatly simplified by eliminating the distributed nature of the acceleration process; nonetheless it represents the concept. The first two terms includes the gap voltage generated by the Marx and Blumlein, along with their interactions with the timeisolation and power feed coaxial lines, and the cell features. The injector voltage has added complexity because of the reflections in the cathode and anode stalks. The accelerator term denoting the unloaded cell voltage is not a part of this discussion. The third term is derived from the beam-induced gap voltage that launches an electromagnetic (EM) wave into the cell and pulse-power system. Reflections are created at components with different impedances, and they * This work was performed under the auspices of the U.S. Department of Energy by University of California, Lawrence Livermore National Laboratory under Contract W-745-Eng-48. -783-9189-6/5/$2. 25 IEEE. 112

Report Documentation Page Form Approved OMB No. 74-188 Public reporting burden for the collection of information is estimated to average 1 hour per response, including the time for reviewing instructions, searching existing data sources, gathering and maintaining the data needed, and completing and reviewing the collection of information. Send comments regarding this burden estimate or any other aspect of this collection of information, including suggestions for reducing this burden, to Washington Headquarters Services, Directorate for Information Operations and Reports, 1215 Jefferson Davis Highway, Suite 124, Arlington VA 2222-432. Respondents should be aware that notwithstanding any other provision of law, no person shall be subject to a penalty for failing to comply with a collection of information if it does not display a currently valid OMB control number. 1. REPORT DATE JUN 25 2. REPORT TYPE N/A 3. DATES COVERED - 4. TITLE AND SUBTITLE Flash X-Ray (Fxr) Accelerator Optimization Injector Voltage-Variation Compensation Via Beam-Induced Gap Voltage 5a. CONTRACT NUMBER 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) 5d. PROJECT NUMBER 5e. TASK NUMBER 5f. WORK UNIT NUMBER 7. PERFORMING ORGANIZATION NAME(S) AND ADDRESS(ES) Lawrence Livermore National Laboratory, PO Box 88, L-153 Livermore, CA, 94551 8. PERFORMING ORGANIZATION REPORT NUMBER 9. SPONSORING/MONITORING AGENCY NAME(S) AND ADDRESS(ES) 1. SPONSOR/MONITOR S ACRONYM(S) 12. DISTRIBUTION/AVAILABILITY STATEMENT Approved for public release, distribution unlimited 11. SPONSOR/MONITOR S REPORT NUMBER(S) 13. SUPPLEMENTARY NOTES See also ADM2371. 213 IEEE Pulsed Power Conference, Digest of Technical Papers 1976-213, and Abstracts of the 213 IEEE International Conference on Plasma Science. IEEE International Pulsed Power Conference (19th). Held in San Francisco, CA on 16-21 June 213., The original document contains color images. 14. ABSTRACT Lawrence Livermore National Laboratory (LLNL) is evaluating design alternatives to improve the voltage regulation in our injector and accelerator cells of our Flash X-Ray (FXR) machine. The operational peak electron beam current and energy at the x-ray generating target are 3.2 ka and 17 MeV. The goal is to create a more mono-energetic electron beam with variation of less than 1%-root-mean-squared (rms). This would allow the beam to be focused more tightly and create an x-ray source with a smaller spot-size. Our injector appears to have significant voltage-variation, and this report describes a technique to appreciably correct the deviations. 15. SUBJECT TERMS 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF ABSTRACT SAR a. REPORT b. ABSTRACT c. THIS PAGE 18. NUMBER OF PAGES 4 19a. NAME OF RESPONSIBLE PERSON Standard Form 298 (Rev. 8-98) Prescribed by ANSI Std Z39-18

eventually affect the voltage in the gap. To concentrate on the compensation analysis, we will assume that the cell and pulse-power system impedance is constant. The FXR injector diode uses two voltage adders, the cathode is driven by six cells, and a hollow anode stalk is driven by four cells. Adding up the individual cell voltages to get the injector voltage will not be accurate because of the reflections in the stalks. Fortunately, the beam current is routinely and accurately measured. By reversing the diode equation (2 and 3) we can estimate the voltage profile, V cath-anode, from the beam current, I beam. The constant k is a conversion number and equal to 8.1 1 7 for I beam = 3.2 ka and V cath-anode = 2.5 MV. I beam (t) = k V cath-anode (t) 3/2 (2) V cath-anode (t) = I beam (t) 2/3 / k (3) The beam current at the head and tail of the beam is reduced about 16% from the peak. The upper portion of the inferred injector voltage is shown in Figure 1, and the beginning and end of the pulse is down about 11%. For precision accelerators, this is a large variation. The average voltage is estimated to be 2.4 MV. Inferred Inject V (MV) 2.55 2.5 2.45 2.4 2.35 2.3 2.25 avg 6 ns 2.2-12 2 4 6 8 Time (ns) 2-2 -4-6 -8-1 Infer Volt Variation (%) Figure 1. The inferred injector voltage shows a large drop of 11% for a 6 ns interval. The variation is 73 kv-rms, or 3.%-rms for the 6 ns interval. If we scale this variation by the energy at the target of 17.5 MV, the variation is.43%-rms. The estimated injector characteristics are shown in Table 1. Table 1. Characteristics of inferred injector voltage. * normalized to 2.4 M ** normalized to 15 MV for accelerator II. INJECTOR VOLTAGE-VARIATION COMPENSATION A. Theory In this section, the mathematical basis for injector variation compensation will be presented. The goal is to determine the best cell and pulse-power system impedance that will minimize injector voltage-variation. The target energy equation (1) can be rewritten as a simplified voltage equation (4) by removing the electron charge V injector (t) + V accelerator (t) V induced (t) = V target (t) (4) Each term is time varying and spatially distributed. The spatial nature of the acceleration process is not important in this discussion. To focus on the voltage-variation compensation concept, we will assume all the voltage sources are collocated. The beam-induced gap voltage is simply the beam current times the gap impedance. If we assume a constant impedance in the gap, cell and pusle-power system, the induced voltage for a cell is V induced-cell (t) = I beam (t) * Z cell (5) The objective is to balance the change in the injector with the opposite change in the gap. Focusing on just the injector and gap voltage, the difference between the injector and induced voltages, applying equation (5), for n cells is V injector-induced (t) = V injector (t) I beam (t) * Z cell * n (6) Substituting for the current from equation (1), we get V injector-induced (t) = V injector (t) k V injector (t) 3/2 * Z cell * n (7) This difference does not have to be zero, only a constant, but the variation needs to be minimized. V injector (t) k V injector (t) 3/2 * Z cell * n = constant (8) 113

We do this by differentiating the difference equation (8) and setting the result equal to zero. {dv injector (t)/dt} {(k n Z cell ) (3/2) V injector (t) 1/2 (dv injector (t)/dt)} = (9) {1 (k n Z cell ) (3/2) V injector (t) 1/2 } (dv injector (t)/dt) = (1) There will be injector voltage-variations, so dv injector (t)/dt cannot be equal to zero. Therefore, to minimize the variation in the difference the term, V injector-induced (t), the result in the { } of equation (1) must be zero. 1 (k n Z cell ) (3/2) V injector (t) 1/2 = (11) Z cell = 1 / { (k n) (3/2) V injector (t) 1/2 } (12) The optimal cell and pulse-power system impedance depends on the diode conversion constant, the number of cells, and the injector voltage. Because the injector voltage is time varying, the value of Z cell must also change to make the variation of the difference zero. In theory, perfect compensation is possible, but changing Z cell in time is extremely difficult. Instead we will choose a single value for Z cell and use a simple computer simulation, to quantify the effectiveness of compensation. For an average injector voltage of 2.4 MV and with 44 cells in the accelerator, the gap impedance should be 12.1 Ω. (See Figure 2.) Fortunately, we are operating at a high voltage where the slope of the curve is not very steep, and our uncertainty about the injector voltage will not seriously change the optimal impedance. Z cell (ohm) 3 25 2 15 1 5 FXR injector voltage..5 1. 1.5 2. 2.5 3. 3.5 4. Injector Volt (MV) Figure 2. The optimal gap impedance for an injector voltage of 2.4 MV and 44 cells is 12.1Ω B. Simulation A simplified computer simulation is used to quantify the effectiveness of injector voltage-variation compensation. An idealized injector voltage profile is put forth because the real data has noise that would degrade the accuracy of the analysis. The idealized injector voltage is shown in Figure 3 denoted with a dashed line. The 6 ns waveform is composed of a portion of a sine wave and an offset. The maximum amplitude is set at 2.5 MV, sine wave amplitude was chosen to provide a variation of 3%-rms to match the inferred variation discussed in the previous section. This profile should reasonably represent the injector voltage. Figure 3. Injector voltage-variation compensation works extremely well for 12.1 Ω. The calculated beam current is shown in the top curve. The total beam-induced voltage for all the cells is negative and is shown in the bottom curve, and to a high degree it has the reverse profile of the injector voltage. The compensated injector voltage is very flat. The compensated voltage-variation is very low, less than.1%-rms. The percentage of variation normalized to the peak injector voltage is shown Figure 4. While not every point can be perfectly corrected, compensation does work exceptionally well. Injector - Induced (MV).85.8.795.79.785 -.4-1 1 2 3 4 5 6 7 Time (ns).4.3.2.1 -.1 -.2 -.3 Figure 4. Expanded near perfect compensated injector voltage shows very little variation. III. EVALUATION OF ALTERNATIVE GAP IMPEDANCES In this section, the effectiveness of compensation with different cell and pulse-power system impedances will be evaluated. Using our model for determining the voltage-variation with an average injector voltage of 2.4 MV, the percentage of compensated injector voltagevariation for a range of impedances is given in Figure 5. Without compensation, the variation is simply the variation of the injector voltage, 3%-rms. As expected, the optimal impedance of 12.1 Ω derived in the previous Inj - Ind (% - norm V inj) 114

section produces the minimum variation. Compensation works fairly well on FXR, but this could still be improved. Net Injector Variation (%-rms) 3.5 3. 2.5 2. 1.5 1..5 without compensation FXR Series Ideal For injector = 2.4 MV. 2 4 6 8 1 12 14 16 18 2 22 24 Cell / PP System Impedance (ohm) Figure 5. Compensation works on FXR but it could be better. A comparison of the effectiveness of compensation for four impedances is given in Table 2. Note that the average injector voltage is lowest when compensation works best. There is no free lunch. Table 2. Comparison of compensation effectiveness for various impedances. An assumption was made at the beginning of the analysis about the value of the injector voltage. A sensitivity study is presented using the optimal impedance of 12.1 Ω. The results are shown in Figure 6. With the optimal cell and pulse-power system impedance, compensation will work over a range of injector voltages. A 1% change from our estimated average injector voltage of 2.4 MV will increase the compensated variation only.15% to.2%. Therefore, the compensation technique requires only a modestly accurate measurement of injector voltage. Net Injector Variation (%-rms).4.3.2.1 Injector Voltage (MV-average) 1.9 2.4 2.9 for Z = 12.1 ohm. -2-15 -1-5 5 1 15 2 Average Injector Voltage Change (%) Figure 6. With the optimal impedance, compensation will work well over a range of injector voltages. The results from this study will be incorporated into a larger accelerator system-model to quantify their effect on total beam energy variations. The compensated injector voltage-variation is reduced to about 4% of the injector variation. IV. ACKNOWLEDGMENTS I want to acknowledge the contributions of Brian Guidry, Bill DeHope, Blake Kreitzer and Aaron Jones who worked hard to measure FXR cell voltages. The ideas for improving voltage regulations came from many people including Ron Kihara, Dave Goerz, George Vogtlin, Jan Zentler, Bill DeHope and Ray Scarpetti. Because of their vast accelerator experience, I particularly appreciate John Weir s, Tim Houck s, and Glen Westenskow s review of this report. I want to especially thank B-Program and Dave Goerz for funding this work. V. REFERENCES [1] Multhauf, L.G., The LLNL Flash X-ray Induction Linear Accelerator, LLNL, Livermore, CA, UCRL-JC-148543, Sept 19, 22. [2] Ong, Mike, George Vogtlin, Dave Goerz and Ray Scarpetti, Flash X-Ray (FXR) Accelerator Optimization, 14 th IEEE International Pulsed Power Conference, Dallas, TX, June 23, pp. 99-12. [3] Ong, Mike and George Vogtlin, Flash X-Ray (FXR) Accelerator Optimization - Beam-induced Voltage Simulation and TDR Measurements, Lawrence Livermore National Laboratory, UCRL-TR-25798, April 24. [4] Ong, Mike and George Vogtlin, Flash X-Ray (FXR) Accelerator Optimization Injector Voltage-variation Compensation via Beam-Induced Gap Voltage, Lawrence Livermore National Laboratory, UCRL-TR- 25798, April 24 (full report). 115