Fixed Series Compensation

Similar documents
Application for A Sub-harmonic Protection Relay. ERLPhase Power Technologies

Transient Recovery Voltage (TRV) and Rate of Rise of Recovery Voltage (RRRV) of Line Circuit Breakers in Over Compensated Transmission Lines

A New Subsynchronous Oscillation (SSO) Relay for Renewable Generation and Series Compensated Transmission Systems

Tab 2 Voltage Stresses Switching Transients

Stabilized Differential Relay SPAD 346. Product Guide

Great Northern Transmission Line: Behind the (Electrical) Design

High-set undervoltage stage with definitetime. or inverse definite minimum time (IDMT) characteristic. Low-set undervoltage stage with definitetime

Transformers connected via a cable Overvoltage protection

Fault indicator. Application. SPEF 3A2 C 1MRS MBG Issued: April 1999 Status: Updated Version: B/ Data subject to change without notice

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

SPAD 346 C Stabilized differential relay

Excitation Systems THYRIPART. Compound-Excitation System for Synchronous Generators. Power Generation

Onsite Mobile AC High Voltage Test System

Advanced Test Equipment Rentals ATEC (2832) Lightning Surge Simulator LSS-F02.

Appendix S: PROTECTION ALTERNATIVES FOR VARIOUS GENERATOR CONFIGURATIONS

SGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications:

DOBLE F6150SV TECHNICAL SPECIFICATIONS

MODIFICATION OF THE ARRESTER ARRANGEMENT WHEN CONVERTING THE METHOD OF NEUTRAL TREATMENT

Numbering System for Protective Devices, Control and Indication Devices for Power Systems

satech SynchroStar GPS 200 Series

ESB National Grid Transmission Planning Criteria

Table of Contents. Introduction... 1

High voltage engineering

MEDIUM & HIGH VOLTAGE

Analysis of Major Changes to Arrester Standards IEC STEVE BREWER

Utility Communications Teleprotection Equipment TPT-200

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

High voltage shunt capacitor banks HIGH VOLTAGE COMPENSATION AND HARMONIC FILTERING PRODUCTS

SPAE 010, 011 High Impedance Protection Relay

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.

AORC Technical meeting 2014

CONTENTS. 1. Introduction Generating Stations 9 40

PS-3000-AVAS PS-5000-AVAS DC SOURCE FOR AUTOMOTIVE TESTS

NPRG860 & NPRG870 perform synchronization and paralleling of generators with electrical network. NPRG860 features a speed adjustment function.

Specifications. S&C BankGuard Plus Controls. For Substation Capacitor Banks and Shunt Reactors. Conditions of Sale

NPRG860 NPRG870 REGULATION. Automatic Synchronizer for Generator

BUS2000 Busbar Differential Protection System

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Wind Aggregated Generating Facilities Technical Requirements

Detecting and Managing Geomagnetically Induced Currents With Relays

Digital Fault Recorder Deployment at HVDC Converter Stations

Optimizing HV Capacitor-Bank Design Protection & Testing

Research on State Estimation and Information Processing Method for Intelligent Substation

Magnetization System of Magnetically Controlled Shunt Reactors

Power Frequency Withstand Voltage On-site testing of 400 kv GIS

SolidGround TM grid stability and harmonics mitigation system Geomagnetic Storm Induced Current (GIC) and Electromagnetic Pulse (EMP) protection

PSV3St _ Phase-Sequence Voltage Protection Stage1 (PSV3St1) Stage2 (PSV3St2)

DIFFERENTIAL CURRENT GENERATOR «POCDIF» (AC/DC - 32A - 50V - 12 ranges)

TABLE OF CONTENT

Course ELEC Introduction to electric power and energy systems. Additional exercises with answers December reactive power compensation

Excitation Systems RG3 - T4. Transistorized Excitation Systems for Synchronous Generators. Power Generation

ECE 422/522 Power System Operations & Planning/Power Systems Analysis II 5 - Reactive Power and Voltage Control

A Review Comprehension: Guideline for Testing of HV, EHV and UHV Substation Equipment

Fault Analysis. EE 340 Spring 2012

EVALUATION OF DIFFERENT SOLUTIONS OF FAULTED PHASE EARTHING TECHNIQUE FOR AN EARTH FAULT CURRENT LIMITATION

System Protection and Control Subcommittee

User-selectable output bus voltages for optimized voltage/current matching to load requirements.

Končar TMS - Bushing monitoring

Technical Specification

Employing Reliable Protection Methods for Automotive Electronics

No. SSIEC-SEW SHINSUNG. Solid Insulation Eco Load Break Switch (SILO) SILO SERIES 15kV, 27kV 400A, 630A

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Aggregated Generating Facilities Technical Requirements

Protection Basics Presented by John S. Levine, P.E. Levine Lectronics and Lectric, Inc GE Consumer & Industrial Multilin

Capacitive Voltage Substations Ferroresonance Prevention Using Power Electronic Devices

Multimeter 500CVD21 RTU500 series

Technical Specification

2. Current interruption transients

Generation Interconnection Requirements at Voltages 34.5 kv and Below

Design and Simulation of Passive Filter

I. INTRODUCTION IJSRST Volume 3 Issue 2 Print ISSN: Online ISSN: X

AC CURRENT GENERATOR POC-6000 (current from 0 to 1000 ARMS)

A Pyrotechnic Fault Current Limiter Model for Transient Calculations in Industrial Power Systems

High Stability Voltage Source

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point

SIOV metal oxide varistors

PQ for Industrial Benchmarking with various methods to improve. Tushar Mogre.

Voltage Sags Evaluating Methods, Power Quality and Voltage Sags Assessment regarding Voltage Dip Immunity of Equipment

Zambezi (previously Caprivi) Link HVDC Interconnector: Review of Operational Performance in the First Five Years

Combo Hot Swap/Load Share Controller Allows the Use of Standard Power Modules in Redundant Power Systems

Protection of Electrical Networks. Christophe Prévé

A Guide to the DC Decay of Fault Current and X/R Ratios

Earthing of Electrical Devices and Safety

CAR - TEST - SYSTEM 14

3 Pole high impedance differential relay 7VH83

GENERATOR TESTING APPLICATION GUIDE. reliable. precision.

Tab 8 Surge Arresters

Improve asset protection and utilization

RS232. DC POWER SUPPLY 20kW 3 RANGES

DC current interruption tests with HV mechanical DC circuit breaker

Optimizing HV Capacitor Bank Design, Protection, and Testing Benton Vandiver III ABB Inc.

System grounding of wind farm medium voltage cable grids

Sequence Networks p. 26 Sequence Network Connections and Voltages p. 27 Network Connections for Fault and General Unbalances p. 28 Sequence Network

PJM Manual 07:: PJM Protection Standards Revision: 2 Effective Date: July 1, 2016

Highgate Converter Overview. Prepared by Joshua Burroughs & Jeff Carrara IEEE PES

FGJTCFWP"KPUVKVWVG"QH"VGEJPQNQI[" FGRCTVOGPV"QH"GNGEVTKECN"GPIKPGGTKPI" VGG"246"JKIJ"XQNVCIG"GPIKPGGTKPI

Chapter -3 ANALYSIS OF HVDC SYSTEM MODEL. Basically the HVDC transmission consists in the basic case of two

Overview of Actuation Thrust

SAFETY ASPECTS AND NOVEL TECHNICAL SOLUTIONS FOR EARTH FAULT MANAGEMENT IN MV ELECTRICITY DISTRIBUTION NETWORKS

Transformer protection IED RET 670

Electricity Ten Year Statement November Electricity Ten Year Statement November Appendix D

Transcription:

Fixed Series Compensation High-reliable turnkey services for fixed series compensation NR Electric Corporation

The Fixed Series Compensation (FSC) solution is composed of NR's PCS-9570 FSC control and protection system, and circuit breaker monitoring & control devices, that are used to achieve series compensation protection, spark gap trigger, and switching order of control. 2 www.nrelect.com

Configuration The capacitor is connected in series with the transmission line to compensate the inductive reactance of the transmission line. The small change of transmission line equivalent inductance can significantly increase the transmission capacity. Without FSC With FSC Figure 1. The transmission capacity increases with FSC Another important benefit is to reduce transmission losses by optimizing the active power share between parallel lines. Figure 2. Balance power distribution with FSC The fixed series compensation equipment is installed in the transmission line to achieve the following advantages: Improve the transmission capacity of lines Improve system transient stability Change system power distribution and reduce network losses Change voltage distribution 3 www.nrelect.com

Configuration NR's PCS-9570 series compensation solution includes capacitors, MOV, damping circuit, spark gap, bypass switch, series compensation platforms, electronic transformer, and protection and control system. This unique solution is suitable for the series compensation of AC transmission lines with 66kV to 1000kV. The protection part integrates capacitor unbalance current protection, capacitor overload protection, arrester overload protection, arrester unbalance protection, platform flashover protection, sub-synchronous resonance protection, capacitor discharge protection, line current monitoring, gap protection, discharge trigger circuit supervision, three-phase position inconsistent protection, bypass breaker failure protection, device out-of-power protection, and fiber optic systems fault detection. The Control part includes sequence control function, screen monitor, alarm, switching disconnectors interlocking and remote upload information. 4 www.nrelect.com

Configuration FSC mainly consists of the following components: Capacitor bank Capacitor banks are used to achieve the compensation for transmission line inductance so as to reduce the electrical distance between two substations and improve the system transient stability. MOV MOV has good non-linear characteristic. It provides overvoltage protection for capacitor banks to limit the overvoltage cross capacitor bank at the protection level 2.0pu ~ 2.5pu (typically) or less, to ensure the safe operation of capacitor bank. Spark Gap The duration from turn-on command issuing to completely spark gap conduction is less than 1ms. It prevents the MOV against damage due to the excessive absorption of energy. Damping Circuit The damping device comprises damping reactors and linear resistor string gap (or non-linear resistance). When the series compensation device is in bypass state, the damping circuit can facilitate and speed up the energy storage in capacitor. Bypass Switch The closing time of bypass switch is longer than the conduction time of spark gap, but it can cause the spark gap interrupted. In addition, it provides normal operation and maintenance functions for series compensation devices. 5 www.nrelect.com

Configuration Control and Protection The typical configuration of series compensation is shown as below. Protection devices and trigger gap control are in reduendant design. The switching control device integrates conventional circuit breaker monitoring and control functions in one rack. The protocol converter and the remote device can be configured according to the actual situation. The remote control unit provides distant sequence control of series compensation to realize free-maintance station. 6 www.nrelect.com

Functions Protection Functions Table 1 presents each function of capacitor bank protections PCS-9570C during its operation. Protection Function Alarm Bypass Trigger Spark Gap Permanent Lockout Temporary Lockout Permanent Bypass Reinsert Other Capacitor Overload Alarm Capacitor Capacitor Overload Bypass #1 #2 Capacitor Unbalance Alarm Capacitor Unbalance Low-set Protection Capacitor Unbalance High-set Protection MOV High current Protection MOV Energy Low-set Protection MOV MOV Energy High-set Protection MOV Temperature Protection MOV Unbalance Protection Spark Gap Bypass Breaker Gap Self Trigger Protection #3 #4 Gap long Conduction Protection Remote Trip Lines Breakers Refuse/Delay Trigger Protection Breaker Close Failure Protection Remote Trip Lines Breakers Breaker Open Failure Protection Pole Disagreement Protection Platform Flashover Protection Cap Discharge Protection #5 Other SSR Protection Line Current Supervision Lockout Reinsert Trigger Circuit Monitoring #1 Permanent bypass if the number of capacitor overload exceeds the setting. #2 Reinsert if the number of capacitor overload is less than the setting. #3 Permanent bypass if the number of gap self trigger exceeds the setting. #4 3-phases reinserting if the number of gap self trigger exceeds the setting. #5 The gap trigger optical pulse will be emitted if the capacitor instantaneous voltage exceeds the setting. 7 www.nrelect.com

Functions Control Temporary or permanent lockout. Support double bypass circuit breaker. Auto-reinserting (single-pole and/or three-pole). Trigger the spark gap. The maximum time delay from the point where MOV high-current and/or high-energy bypass threshold is exceeded to Spark Gap conduction shall not exceed 1 ms. Dual FSC protection system to avoid the failure of bypassing series capacitors. Communication Merging unit communication to protection system based on IEC60044-8 protocol. Ethernet ports supporting IEC 61850 protocol. 2 RS-485 ports supporting IEC 60870-5-103 protocol and clock synchronization. 1 RS-232 ports or RS-485 for printer and 1 RS-232 frontpanel port for testing and setting. GPS clock synchronization. Spark Gap The gap discharge voltage is set higher than that established by MOV protection. The gap receives forcing trigger command and is triggerred quickly. The gap can not be triggered without receiving the triggering command. The spark gap can withstand the discharging current of capacitor bank at a specified protection voltage level. The Gap Trigger Electronic (GTE) device uses dual laser energy to avoid EMI caused by high potential power supply. Low-power CPLD can realize trigger command processing, closed-loop power control and equipment self-test. The trigger command processing delay is about 20us. The entire conduction time of the spark gap (from GTE receiving the trigger command to the spark gap completely turn-on) is less than 100 μs. The ignition gap uses double seal structure with good immunity to wind speed and humidity. The ignition device has a special electrical discharge machine and a precise installation equipment to make the trigger voltage stable and accurate. Within the adjustment duration, the trigger voltage error is less than 5%. Each ignition gap has two GTEs to work with dual sets of protection to form a redundant configuration. Ignition pulse will be output if the trigger command is received by any GET. The trigger system has good anti-emi capability in case of switching arc and gap conduction. 8 www.nrelect.com

Features The PCS-9570 series products are developed based on NR's solid AC high voltage protection principles and years' of experience. It provides protection and control solutions for AC transmission line capacitors in series compensation system. It features: Safe and reliable primary equipment The PCS-9570 system adopts safe and reliable primary equipment such as capacitors, MOV, spark gap, damping device, electronic transformer and protection & control system. Unified UAPC platform The self-developed UAPC platform has visual programming software and hardware modular configuration. It is flexible for expansion. Communications between hardware modules are fulfilled by internal high-speed bus. The operation of duplicated protections are fully independent. The starting components are combined with protection output to increase operation reliability. The use of electronic transformer greatly improves its anti-interference capability. Interposing relay sets are developed for the closing of series compensated bypass switch. The control and protection module can facilitate the realization of sequence characteristics of series compensation equipment. Measurement and control devices are fully complied with IEC61850. Operators can enable or disable dispatching of series compensation devices through the remote one-touch control function. Easy-to-use testing device. The conventional relay tester can ease the on-site inspection of series compensation system. 9 www.nrelect.com

Case Study HeChi Substation Series Compensation Hechi series compensation is installed in Hechi substation of Southern Power Grid. its series compensation degree is 50%. The related parameters are shown in the table below. After completing all equipment installation and commissioning, the manual ground short circuit test is executed to prove that the entire control and protection system can well meet the specified requirements. Technical Parameters Value Rated voltage (kv rms) 525 Three-phase Capacity (MVA) 476.0 Compensation degree 50% Rated current (A) 2400 Rated phase voltage (kv rms) 66.1 Each phase capacitance (μf) 115.6 Each phase series impedance (Ω) 27.55 Protection level (p.u.) 2.37 NR provides the following study and services in this project: Study series compensation voltage and check series compensation device parameters. Test the new gap trigger system to see if it can trigger the original seal gap, verify that the new gap trigger complies well with the original spark gap; Measure the thermal characteristics of original MOV devices curve. The MOV thermal protection simulation model remains the same as the actual cooling curve to ensure reliable operation of MOV; Perform the RTDS test for protection & control system to test the performance of series compensation. BaiSe Substation Series Compensation The technical data of 500kV BaiSe series compensation project is shown in the table below. Technical Parameters Value Rate voltage (KVrms) 525 Three-phase rated capacity (MVA) 542 Compensation degree 50% Rated current (A) 2400 Rated phase voltage (kv rms) 75.3 Each capacitance (μf) 101.47 Each series impedance (Ω) 31.37 Protection level (p.u.) 2.3 NR provides the follow study and services to ensure the reliable operation of series compensation in Baise project: Overvoltage simulation of power network including series compensation. Platform stress analysis and a variety of load checking. Insulation coordination study. Spark gap development and type test. RTDS test of control and protection system. 10 www.nrelect.com

NR Electric Co., Ltd. Add: 69 Suyuan Avenue, Jiangning, Nanjing 211102, China Tel: +86-25-8717 8888 Fax: +86-25-8717 8999 NRsales@nrelect.com NRservices@nrelect.com www.nrelect.com Copyright NR 2012.08 All rights reserved