Switching spark gap. SSG with lead wires B88069X3790T502 FS08X-1JG

Similar documents
Switching spark gap. SSG without lead wires B88069X7391T602 FS08HF1BSMD

Switching spark gap. SSG with lead wires B88069X3440S102

Switching spark gap. SSG with lead wires B88069X3450T502 FS1X-1G

Switching spark gap. SSG with lead wires. B88069X0340xxxx a) FS08X-1GH

Surge arrester. 2-electrode arrester. B88069X2500xxxx a) EM2500XS

Surge arrester. 2-electrode arrester B88069X9761B201 H25-E70X

Surge arrester. 3-electrode arrester B88069X9701T702 T30-A250XFSMD

Surge arrester. 3-electrode arrester B88069X7200B502 T23-A350X

Surge arrester. 3-electrode arrester B88069X6731T702 T30-A230XSMD

Surge arrester. 2-electrode arrester B88069X1620T602 A80-A230XSMD

Surge arrester. 2-electrode arrester B88069X3433B251 V87A-A600XP1

PPD AB PD / PPD AB PM

PTC thermistors. Thermal management in LED driver circuits, EIA size Date: December 2007

B88069X1630T602 A80-C90XSMD PPD AB PD / PPD AB PM

B88069X3651T902 T20-A230XSMDN PPD AB PD / PPD AB PM

Surge Arrester. 3-Electrode-Arrester. T83-A230X B88069X8910B502 Date: Version: Issue 03. Series/Type: Ordering code:

PPD AB PD / PPD AB PM

EMC filters. Date: November 2012

Film Capacitors Power Factor Correction

B5114 B39781B5114U410 Mar 19,

Film Capacitors Power Factor Correction

Inductors. VHF chokes B82114 MAG IN PD

Film Capacitors AC Capacitors

SHDSL interface transformer

B1653 B39122-B1653-B510 December 18,

Film Capacitors Power Factor Correction

SMT Power Inductors. ERU 20, helically wound B82559*A020

Ferrites and accessories

PPD AB PD / PPD AB PM

B9417 B39162B9417K610 January 23,

Film Capacitors AC Capacitors

Film Capacitors AC Capacitors

Transformers. DC/DC converters E 6.3. Series/Type: B78304B*A003 Date: October 2012

Data and signal line chokes

B3404 B39232-B3404-U410 April 08,

B3520 B39162B3520U410 February 22,

B5235 B39141B5235Z810 Sep 23,

B9508 B39202B9508L310 February 18,

R880 B39431R 880H210 February 04,

Inductors. RF chokes, LBC series, mm. Date: June 2011 Version:

Film capacitors Power Factor Correction

SMT Push-Pull Transformers

SMT power inductors. Size 12.5 x 12.5 x 8.5 (mm) B82477R4

B9474 B39162B9474P810 October 19,

SMT power inductors. Size (mm) Date: March 2008

B5139 B39262B5139U410 June 18,

B9513 B39202B9513L310 May 27,

SMT power inductors. Size (mm) Date: March 2008

Film Capacitors AC Capacitors

Installation and maintenance instructions for capacitor contactors

Film capacitors Power Factor Correction

SMT power inductors. Size 12.5 x 12.5 x 8.5 mm B82477D4 MAG IN PD

B9522 B39182B9522P810 December, 12,

B3913 B39162B3913U410 January 31,

B9430 B39252B9430M410. September 02,

B8313 B39162B8313P810 February 12,

Inductors. VHF chokes. Date: June 2012

Film Capacitors AC Capacitors

B3725 B39871B3725U410 May 16,

B3470 B39162B3470H910 February 14,

B9898 B39272B9898P810 May 15,

B3710 B39431B3710U410 December 17,

2 line filters for converters and power electronics

SMT current sense transformers. EE 5.0 core. Series/Type: B82801B Date: December 2012

SMT power inductors. Size (mm) Date: June 2012

SAW Components. SAW filter. Automotive telematics. B3519 B39162B3519U410 May 08, Series/type: Ordering code: Date: Version:

SMT power inductors. Size (mm) Date: June 2012

B9456 B39881B9456P810 December 07,

LTE Band 17 (lower 700MHz band, blocks B and C) B8566 B39741B8566P810 February 06,

B3517 B39162B3517U510 January 30,

SMT inductors. SIMID series, SIMID 1812-A. Date: October 2012

B8831 B39242B8831P810 August 18,

Power line chokes. Current-compensated ring core triple chokes 440/250 V AC, 12 A, 0.35 mh. Series/Type: B82745S6123N002 Date: July 2012

Data and signal line chokes

B8094 B39212B8094P810 April 03,

Film Capacitors AC Capacitors

B4402 B39781B4402P810 June 13,

Power line chokes. Current-compensated frame core double chokes 250 V AC, A, mh, +40 C. Series/Type: B82733F Date: March 2011

SMT power inductors. Size (mm) Date: June 2012

Inductors. VHF chokes B82131, B82132, B82133, B Date: June 2012

SAW Filters for Automotive Electronics

B7943 B39262B7943P810 November 7,

B82462G2*

SAW Components. SAW RF filter. RF360 Europe GmbH. A Qualcomm TDK Joint Venture. Short range devices. Date: December 01, 2010 Version: 2.

Power line chokes. Current-compensated D core double chokes 250 V AC, A, mh. Series/Type: B82731M/H Date: March 2008

Inductors. RF chokes, LBC series. Date: June 2012

B7654 B39881B7654P810 December 28,

Inductors. RF chokes, BC series. Date: March 2008

Inductors. RF chokes, LBC series. Date: June 2012

SAW Components. SAW RF filter. RF360 Europe GmbH. A Qualcomm TDK Joint Venture GPS. Date: August 25, 2011 Version: 2.1

SAW Components. SAW RF low loss filter. RF360 Europe GmbH. A Qualcomm TDK Joint Venture. Satellite CSS. Date: October 01, 2010 Version: 2.

Current-compensated frame core double chokes 250 V AC, A, mh, +40 C

Power Quality Solutions

SMT inductors. SIMID series, SIMID 2220-A. Date: October 2012

B3533 B39431B3533A410 December 20,

Data and signal line chokes

SMT inductors. SIMID series, SIMID 1210-T. Date: October 2012

Power line chokes. 3.4 µh / 1 MHz, 25 A, +110 C. Ordering code: B82116B2828A010. Date: Version: 01

Film Capacitors Power Factor Correction

SAW Components. SAW resonator. RF360 Europe GmbH. A Qualcomm TDK Joint Venture. Short range devices. Series/type: Date: June 17, 2013 Version: 2.

Transcription:

Series/Type: Ordering code: ersion/date: Issue 03 / 2008-10-29 Content of header bars 1 and 2 of data sheet will be automatically entered in headers and footers! Please fill in the table and then change the color to "white" (or invisible). This ensures that the table disappears for the customer PDF. To update the data sheet, click on the symbol "Preview" and then "Close". Please do not alter the header or footer when copying the content. Identification/Classification 1: (header 1 + top left header bar) Identification/Classification 2: (header 2 + bottom left header bar) Ordering code: (top right header bar) Series/Type: (top right header bar) Switching spark gap Preliminary data (optional): (if necessary) Department: KB AB E / KB AB PM Date: Issue 03 / 2008-10-29 EPCOS AG 2008. Reproduction, publication and dissemination of this document, enclosures hereto and the information contained therein without EPCOS' prior express consent is prohibited.

Features Extremely long life time Stable performance over life Insensitive performance against variations in temperature ery low switching losses ery short breakdown time High reliability by robust design RoHS compatibility Applications Ignition circuits High voltage switch Electrical specifications Nominal breakdown voltage N 800 Initial values 2) Static breakdown voltage S 1) First ignition value S, FTE after 24 hours in darkness Following ignition values S, FI Electrical life time 3) Breakdown voltage B First ignition value B, FTE after 24 hours in darkness Ignition time t I at 0 during life Following ignition values B, FI Switching operations at 40 C at + 25 C at +125 C at +150 C at +170 C (at 40 +170 C ) Test circuit parameters Open circuit voltage 0 Loading resistance R Discharge capacitance C Inductance L Discharge peak current I P General technical data Max. static breakdown voltage at 100 k/s Insulation resistance at 100 Early ignition values < 680 5) Breakdown time Maximum switching frequency Maximum loading current Weight 950 704... 896 1000 S.C. 4) 60 680... 920 S.C. 4) 20 000 70 000 S.C. 4) 70 000 30 000 10 000 (total 200 000 ) 1000 68 100 0.5 ~ 400 1300 > 100 S.C. 4) 1 50 400 50 ~ 2 ms kω nf µh A MΩ % ns Hz ma g Please read Cautions and warnings and Page 2 of 5

Marking, blue positive 1) 2) 3) 4) 5) At delivery AQL 0,65 level II, DIN ISO 2859 Page 2, Fig. 1 and 2 Page 2, Fig. 3 and 4 S.C. = Significant Characteristic No early ignition value < 500 800 WWY O 800 - Nominal voltage WW - Calendar week of production Y - Year of production O - Non radioactive Figures Fig. 1: QC- test circuit (100% outgoing inspection) Fig. 2: Explanation of measurands I = const 51k Ω S, FTE S, FI 0,22 μf DUT S ICU DUT device under test ICU ignition control unit (sensitivity 10... 30 μa) Discharge current 10 20 ma - N d S /dt ~ d N /dt Fig. 3: QC- test circuit (sampling inspection at 25 C) Fig. 4: Explanation of measurands R L B, FTE Range of B, FI B, FTE B N Early i iti O C DUT B t t I 1 s 10 s Please read Cautions and warnings and Page 3 of 5

Dimensional Drawing Not to scale Dimensions in mm Non controlled document Cautions and warnings Switching spark gaps may be used only within their specified values. Damaged switching spark gaps must not be re-used. Please read Cautions and warnings and Page 4 of 5

Important notes The following applies to all products named in this publication: 1. Some parts of this publication contain statements about the suitability of our products for certain areas of application. These statements are based on our knowledge of typical requirements that are often placed on our products in the areas of application concerned. We nevertheless expressly point out that such statements cannot be regarded as binding statements about the suitability of our products for a particular customer application. As a rule, EPCOS is either unfamiliar with individual customer applications or less familiar with them than the customers themselves. For these reasons, it is always ultimately incumbent on the customer to check and decide whether an EPCOS product with the properties described in the product specification is suitable for use in a particular customer application. 2. We also point out that in individual cases, a malfunction of electronic components or failure before the end of their usual service life cannot be completely ruled out in the current state of the art, even if they are operated as specified. In customer applications requiring a very high level of operational safety and especially in customer applications in which the malfunction or failure of an electronic component could endanger human life or health (e.g. in accident prevention or life-saving systems), it must therefore be ensured by means of suitable design of the customer application or other action taken by the customer (e.g. installation of protective circuitry or redundancy) that no injury or damage is sustained by third parties in the event of malfunction or failure of an electronic component. 3. The warnings, cautions and product-specific notes must be observed. 4. In order to satisfy certain technical requirements, some of the products described in this publication may contain substances subject to restrictions in certain jurisdictions (e.g. because they are classed as hazardous). Useful information on this will be found in our Material Data Sheets on the Internet (www.epcos.com/material). Should you have any more detailed questions, please contact our sales offices. 5. We constantly strive to improve our products. Consequently, the products described in this publication may change from time to time. The same is true of the corresponding product specifications. Please check therefore to what extent product descriptions and specifications contained in this publication are still applicable before or when you place an order. We also reserve the right to discontinue production and delivery of products. Consequently, we cannot guarantee that all products named in this publication will always be available. The aforementioned does not apply in the case of individual agreements deviating from the foregoing for customer-specific products. 6. Unless otherwise agreed in individual contracts, all orders are subject to the current version of the General Terms of Delivery for Products and Services in the Electrical Industry published by the German Electrical and Electronics Industry Association (ZEI). 7. The trade names EPCOS, BAOKE, Alu-X, CeraDiode, CSSP, CTS, DSSP, MiniBlue, MKK, MLSC, MotorCap, PCC, PhaseCap, PhaseMod, SIFERRIT, SIFI, SIKOREL, SilverCap, SIMDAD, SIMID, SineFormer, SIO, SIP5D, SIP5K, ThermoFuse, WindCap are trademarks registered or pending in Europe and in other countries. Further information will be found on the Internet at www.epcos.com/trademarks. Page 5 of 5