Single Channel Loop Detector

Similar documents
Single Channel Loop Detector

Single Channel Loop Detector

Single Channel Loop Detector

Single Channel Loop Detector

RME1-RME1BT INSTRUCCIONES DE INSTALACION INSTALLATIEVOORSCHRIFTEN INSTRUCTIONS D INSTALLATION ИНСТРУКЦИИ ПО УСТАНОВКЕ ISTRUZIONI DI INSTALLAZIONE

FLUX 11 Pocket installation manual SENSITIVE INDUCTIVE LOOP DECTOR

Short form User Manual

AGP-0230 USER MANUAL AMANO

USER MANUAL ULD 910. October 2003 Revision: 03. Single Channel Vehicle Detector ULD 910. Part Number: MIC

PD132 Loop Detector Specification

Dual Channel Vehicle Detector ULD 920 USER MANUAL Part Number: MIC ULD 920

BEA s digital inductive single loop solution

USERS GUIDE MATRIX2 DIGITAL INDUCTIVE LOOP SENSORS

USERS GUIDE MATRIX P/N SINGLE DIGITAL INDUCTIVE LOOP SENSOR

Single Channel Loop Vehicle detector User Manual

Inductive Sensors Single or Dual Loop Detectors Type LD with teach-in

601/602 Series Inductive Loop Detector

ULT-MVP O P E R A T I N G I N S T R U C T I O N S ULTRALOOP V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

DSP-10 Vehicle Detector

Operating Instructions

ULT-DIN O P E R A T I N G I N S T R U C T I O N S ULTRALOOP V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

MD12-2 Metal Loop Detector

SMARTSCAN INFORMATION

TECHNICAL MANUAL FOR LOOP DETECTORS WITH POWERFAIL MEMORY Article Codes: RDET1CM & RDET2CM

DSP-21 Directional Counting Detector

DSP-20 Dual Channel Vehicle Detector With Directional Logic

MATRIX INDUCTIVE LOOP CONTROL BOX

PD230 Enhanced Vehicle Detector USER MANUAL

Operating Instructions

With Audible Detect Signal

Operations Manual. Model NT11 & NT11-E. June 18 th 2002

MODEL T-110 SERIES OPERATION MANUAL

LMD622 and LMD624 Series

FG2 TWO-CHANNEL DETECTOR

Four Channel Inductive Loop Detector

Inductive Loop Detector

Dual Channel Traffic/Parking Detector User Guide

MODEL C-1000 SERIES OPERATION MANUAL

Single Channel Loop Detector

SPECIAL SPECIFICATION 6004 Digital Card Rack Inductive Loop Detector Assembly

FACTORY AUTOMATION. MANUAL LC10-* Laying loops for Loop detector LC10-1 and LC10-2

SOUTH DUBLIN COUNTY COUNCIL Traffic Management Centre Roads (Traffic and Transportation) Department

MODEL L-1200 SERIES OPERATION MANUAL

INSTRUCTION MANUAL DAAB LOOP DETECTOR DB402

Underground Loops and Loop Detectors. DoorKing Plug-In Loop Detectors and Loop Accessories Single Channel CH1

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

Double Channel Loop Detector

SET Installation and Operating Instructions. Level switch for two sensors

T25-35SA Subaudible Tone Decoder

Loop Installation. Manual

Electronically Commutated (EC) Motor Control with Solo, Select and Sync PWM Boards

User and Reference Guide Hy5B Vehicle Detector: MX4125

DEIF A/S. Insulation monitor. Type SIM-Q

ITS specification Inductive loops and feeder cables (ITS-03-01)

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES

BlockMon Block Monitor LongMon Long Monitor

05/09/2012

MODEL P-1400 OPERATION MANUAL Firmware Version 4.02

NJM3777 DUAL STEPPER MOTOR DRIVER NJM3777E3(SOP24)

ECM3 EARTH CONTINUITY RELAY

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

1 GHz capable, 3 W carrying power (at 1 GHz), 50Ω impedance and 2 Form C relays

F 6217: 8-channel analog input module

REPAIRING THE RM KL400 LINEAR AMPLIFIER.

Loop Installation. Manual.

GROUP OF COMPANIES. MERLIN STEALTH Electric Fence Energizer INSTALLERS MANUAL

Capacitance Level Switch

Slim type safety relays. FEATURES 1. Acquisition of Korean safety certification ( S mark) Excluding with diode type

Boulder W Class A Stereo Power Amplifier

Timpdon Marine. Club 500 Radio Controlled Motor Controller Model MRCS5. MRCS5 Electrical Specification. Solid State Radio Controlled Motor Controller

INSTRUCTION MANUAL VIBRATION SWITCH CVS 100 LC

Proximity Sensor Terminology

SLIM COMPACT SAFETY RELAY

MODEL P-1400 OPERATION MANUAL. Four Loop Inputs, Two Vital Outputs, and One Vital Input

PROXIMITY SENSOR TERMINOLOGY

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

DEIF A/S. Insulation monitor. Type SIM-Q/SIM-Q LF

CS-200. PORTABLE TRAFFIC LIGHT CONTROLLER (Software 1.05) OPERATION AND SERVICE MANUAL

E-STOP relays, safety gate monitors

Datasheet Platinum Resistance Pt100 In-head (Push Button) Temperature Transmitter TX203P mA output, default range supplied C

Impulse system MPT 700. Manual Edition GB

ENCOUNTER AMPLIFIER MANUAL EN-1502 EN-3001 EN-3004

STATE OF OHIO DEPARTMENT OF TRANSPORTATION SUPPLEMENTAL SPECIFICATION 919 RAILROAD PREEMPTION INTERFACE. January 15, 2016

ENCORE 300 SERIES INSTALLATION AND OPERATING INSTRUCTIONS

Answering frequently asked Questions (Firmware V.107)

USER MANUAL D-CLASS AMPLIFIER CA-DA12250 CA-DA41400 CA-DA Specifications and design are subject to change without notice

Level Lance Model 5100

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

STEADY HAND GAME WITH LATCHING LED

NEXUS Metal Detectors. Telephone +44(0) User Manual

IA502 Multi-Entrance Controller For use w/ IA543, PK543, PK543A, and PK205 Amplifier Systems Installation Instructions

OPERATING INSTRUCTION

MODEL: DAST-20. Telemetering System

INSTALLATION AND OPERATION MANUAL IODA INPUT/OUTPUT MULTI-FUNCTION BOARD (Part No. 9668)

Bi-Directional DC Motor Speed Controller 5-32Vdc (3166v2)

Back to the Basics Current Transformer (CT) Testing

AR.Drone 2 - Main Board External Antenna Modification Procedure. Document Number: EAM Check back for updates.

Transcription:

Single Channel Loop Detector Model - LD116 The LD116 is a single channel inductive loop card detector designed for parking and access control applications. The detector is connected to an inductive loop mounted in the road surface. When vehicles pass over the loop the detector switches on an output. The use of microprocessor and surface mount technology enables a large number of functions to be incorporated into a small package. The LD116 is easy to set-up and install. Applications Typical applications in the parking and access control environments are safety loops for barriers or gates, arming loops for activating card dispensers, entry or exit loops and vehicle counting. Features Switch selectable Sensitivity. The detect sensitivity is the minimum change in inductance required to produce a detect output. (%ΔL/L). Eight sensitivity settings are available on the switches to allow flexibility in configuration. Switch selectable Frequency. The frequency of the loop is determined by the inductance of the loop and the frequency switch setting. If the frequency switch is on, the frequency is reduced. It may be necessary to change the frequency to prevent cross-talk between adjacent loops on different detectors. Sensitivity Boost. This feature sets the undetect level to maximum sensitivity and is used to prevent loss of detection of high-bed vehicles. Filter Option. This option is used to provide a delay of 2 Seconds between detection of the vehicle and switching of the output relay. This delay is normally used to prevent false detection of small or fast moving objects. 1

Extend Option. When switched on this feature extends the presence output relay for 2 Seconds after the vehicle has left the loop. Permanent Presence. This feature ensures detection of the vehicle will be maintained when the vehicle is parked over the loop for extended periods. Pulse Relay Selection. The Pulse relay may be configured to energise on detection of a vehicle or to energise when the vehicle leaves the loop. Selectable Pulse Time. This feature sets the length of time that the pulse relay will be energised. 1 Second or 0.2 Second. Indicators Power Indicator. This LED Indicator illuminates when power is present. Detect Indicator. This LED Indicator is illuminated when there is a vehicle over the loop or the loop is faulty. This LED can also be used to determine the loop frequency. On reset, count the number of times the LED flashes. Multiply this number by 10KHz.For example: if the LED flashes 6 times, then the loop frequency is between 60KHz and 70KHz. Loop Fault Indicator. This LED Indicator is illuminated when the loop is either open circuit or short circuit and is used to give a visual indication of a faulty loop. Technical Specifications Power supply Presence Relay Pulse Relay Response time Indicators Detector tuning range Loop Frequency Environmental tracking Protection Connector Dimensions Operating Temperature Storage Temperature 11-26VAC/DC 50/60Hz 100mA max. Change over contact 0.5A/220VAC (Fail Safe normally energized) Change over contact 0.5A/220VAC(Non Fail Safe normally denergised) Approximately 120ms after vehicle enters loop. LED indicators show: Power, Detect state and Loop Fault. 15-1500uH Approx. 23 130KHz Automatic Compensation Loop isolation transformer with zener diodes and gas discharge tube. 10Way Screw terminal block 110mm X 90mm X 25mm -40 C to +80 C -40 C to +85 C 2

Switch Settings LD113 Switch Settings Switch No. Function ON OFF 10 Presence Relay Extend Time 2 Sec Off 7,8,9 Sensitivity 0.02% - S7/S8/S9 7,8,9 Sensitivity 0.01% S9 S7/S8 7,8,9 Sensitivity 0.05% S8 S7/S9 7,8,9 Sensitivity 0.1% S8/S9 S7 7,8,9 Sensitivity 0.2% S7 S8/S9 7,8,9 Sensitivity 0.5% S7/S9 S8 7,8,9 Sensitivity 1% S7/S8 S9 7,8,9 Sensitivity 2% S7/S8/S9-6 Frequency Low High 5 ASB On Off 4 Filter 2 Sec Off 3 Permanent Presence On Off 2 Pulse Mode Undetect Detect 1 Pulse Time 1 Sec 0.2 Sec Relay Functionality RELAYS VEHICLE PRESENT NO VEHICLE LOOP FAULTY NO POWER PRESENCE RELAY PULSE RELAY N/O CLOSED OPEN CLOSED CLOSED N/C OPEN CLOSED OPEN OPEN N/O PULSE CLOSED OPEN OPEN OPEN N/C PULSE OPEN CLOSED CLOSED CLOSED 3

Diagnostics SYMPTOM POSSIBLE CAUSE SOLUTION The POWER LED is not on. No power supply voltage on the input. Check that the power supply is correctly wired to the detector. (PINS 1 and 2) The DETECT LED flashes erratically. The DETECT LED randomly stays on. The LOOP FAULT LED is flashing. The LOOP FAULT LED is permanently illuminated. There may be a poor connection in the loop or loop feeder. The detector may be experiencing crosstalk with the loop of an adjacent detector. Faulty loop or loop feeder wiring. Movement of the loop in the ground. The loop inductance is to small or the loop is short circuit. The loop inductance is too large or the loop is open circuit. Check all wiring. Tighten screw terminals. Check for broken wires. Try changing frequencies using the frequency switch. Put the detector with the larger loop onto low frequency and the detector with the smaller loop onto high frequency. Check the wiring. Tighten screw terminals. Check for pinched or bent wires. Is the feeder wire twisted? Check for cracks in the road surface near the loop. Check that there is no short circuit on the loop feeder wiring or the loop. If there is no short circuit then the inductance is to small and more turns of wire should be added to the loop. Check that there is electrical continuity on the loop. This can be done using a multimeter on the ohms range (< 5 Ω). If the loop inductance is too large then try reducing the number of turns. Wiring Diagram 8 5 7 PRESENCE RELAY 4 PULSE RELAY OUTPUT OUTPUT 6 3 LOOP TWISTED 9 10 LOOP INPUT 12/24 VAC/DC 0V 1 2 POWER INPUT 4

Wiring Connections Loop Installation Guide 1. The detector should be installed in a waterproof housing as close to the loop as possible. 2. The loop and feeder should be made from insulated copper wire with a minimum cross-sectional area of 1.5mm 2. The feeder should be twisted with at least 20 turns per metre. Joints in the wire are not recommended and must be soldered and made waterproof. Faulty joints could lead to incorrect operation of the detector. Feeders which may pick up electrical noise should use screened cable, with the screen earthed at the detector. 3. The loop should be either square or rectangular in shape with a minimum distance of 1 metre between opposite sides. Normally 3 turns of wire are used in the loop. Large loops with a circumference of greater than 10 metres should use 2 turns while small loops with a circumference of less than 6 metres should use 4 turns. When two loops are used in close proximity to each other it is recommended that 3 turns are used in one and 4 turns in the other to prevent cross-talk. 4. Cross-talk is a term used to describe the interference between two adjacent loops. To avoid incorrect operation of the detector, the loops should be at least 2 metres apart and on different frequency settings. 5. For loop installation, slots should be cut in the road using a masonry cutting tool. A 45 o cut should be made across the corners to prevent damage to the wire on the corners. The slot should be about 4mm wide and 30mm to 50mm deep. Remember to extend the slot from one of the corners to the road-side to accommodate the feeder. 6. Best results are obtained when a single length of wire is used with no joints. This may be achieved by running the wire from the detector to the loop, around the loop for 3 turns and then back to the detector. The feeder portion of the wire is then twisted. Remember that twisting the feeder will shorten its length, so ensure a long enough feeder wire is used. 7. After the loop and feeder wires have been placed in the slot, the slot is filled with epoxy compound or bitumen filler. TRAFFIC DIRECTION 300mm 1 + 12 TO 24VAC/DC SUPPLY 2 0V 3 Pulse Relay COM 4 Pulse Relay N.C. 5 Pulse Relay N.O. 6 Presence Relay COM 7 Presence Relay N.C. 8 Presence Relay N.O. 9 LOOP TWISTED 10 LOOP WIRE 300mm ROAD SURFACE 1M ROAD EDGE SLOT SEALANT WIRES 30-50 mm 45 O CROSSCUT FEEDER 4mm Contact Details Refer to our web site for distributor details. Email: proconel@proconel.com Web: www.proconel.com 5