B9000 FXS kVA B9600 FXS kVA

Similar documents
TECHNICAL DATA SHEET B9600FXS kva

G8000MM Series IGBT. 100 to 750 KVA UPS UNINTERRUPTIBLE POWER SYSTEMS. 94% Efficiency. Input PF >0.98 DESIGN

Chloride 80-NET Secure Power For Mission Critical Applications 60kVA to 120kVA. AC Power For Business-Critical Continuity

Technical Data Sheets

Est Static Frequency Converter. SFX 10kVA - 10MVA

Liebert Hipulse-U. Fully Digital Dual DSP Controlled Transformer Based UPS

SENTINEL XR PLUS 5-10kVA

Est Static Frequency Converter. SFX 10kVA - 10MVA

TOSHIBA International Corp

MGETM EPSTM /625/750/800 kva. Three phase UPS

2.1 Performance Standards The UPS is designed with the applicable sections of UL, CUL, and ISO The UPS has UL and CUL listing.

MODULAR DC POWER SUPPLIES & SYSTEMS. DC Power Systems DC/AC Inverters Static Switches DC/DC Converters. GAMATRONIC, A SolarEdge Division

Series 7400 M (10/20/30/40/60 kva) Maximum Protection For Mission Critical Network Applications. Series 7400 M

ahead of time Static Digital Voltage Stabilisers

Uninterruptible Power System (UPS) 20 to 320 kva


Technical Data Sheet. Uninterruptible Power Supply On-line VH Series UPS. Critical Power UL / 208V

These true on-line inverters incorporate pulse width modulation (PWM) control combined with high frequency igbt power transistors.

GESS Industrial UPS System. Overview

Liebert AF2 Next Generation Active Harmonic Filter. Power Protection for Business-Critical Continuity TM

These true online inverters integrate pulse width modulation (PWM) control combined with high frequency IGBT power transistors.

Strategies for design 600V large modular UPS for critical power applications

Evaluation of transformer-free UPS design vs transformer-based

ULTRA-K Series 600K - he

1KVA-2KVA-3KVA 6KVA-10KVA. NUPS22 Series

Low Pass Harmonic Filters

Introduction: TAS PowerTek Ltd. MAVROS

AC+DC Power Sources. Newtons4th Ltd. N4A06-6kVA Single Phase N4A18-18kVA Three Phase N4A30-30kVA Three Phase Higher Power Systems also Available

RELIABLE SOLUTIONS in POWER ELECTRONICS VRST SERIES. Power Management Instruments ELECTRONIC STABILIZER FROM PMI & OES GROUP COMPANIES SUD

Large-Capacity, High-Efficiency 3-Level UPS for North America 7000HX-T3U

MITSUBISHI ELECTRIC 2033A DDC SERIES SPECIFICATIONS

G-NET. 1 kva-10 kva. Rack & Tower UPS

PRODUCTS FOR ELECTRICAL SUB-STATIONS UPS, DC-AC INVERTERS, BATTERY CHARGERS, DC-DC CONVERTERS, 1-PHASE TO 3-PHASE CONVERTERS

Technical Specifications

Chloride FP-60Z 5 to 60kVA

ahead of time SAG Compensator

R&D TECHNICAL SPECIFI

FCL VOLTAGE & FREQUENCY CONVERTERS. FCL H SERIES - SINGLE PHASE - 2 to 30 kva H SERIES MODELS. AC SINGLE PHASE 2 TO 30 kva STATIC VARIABLE AC

Resilient 3000 EP3000AC48IN Rectifier 3000W Output at 48 58Vdc

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

EL-AC Electronic Load

AC Power Sources. Newtons4th Ltd

DIGITAL SWITCH MODE POWER SUPPLIES MAIN APPLICATIONS GENERAL INTRODUCTION TO QP23 SERIES

HARMONICS THE BASICS H A R M O N I C M I T I G A T I O N A N D D I S P L A C E M E N T P O W E R F A C T O R C O R R E C T I O N

MYS WWSP PLUS III POWER UNIT

UPS (Uninterruptible Power Supply) Digital Signal Processor CM COMANDOS LINEARES CM COMANDOS LINEARES

The power to work. Power conditioning products. Harmonic correction unit Sag ride-through power conditioner

SHORE TO SHIP FREQUENCY

GE+ Grid Emulator. Key features. Highlights. High-Resolution and Dynamics. Efficiency and Flexibility. Smooth Integration. Harmonics Generation

Power Quality Solutions PQSine P-Series of Active Harmonic Filters and Power Optimizers

Power IT LV Active Filters PQFI PQFM PQFK. The ABB comprehensive solution for active filtering of harmonics

Gutor PxW AC UPS Designed for North American Market

BFM136 THE PERFECT SOLUTION FOR MULTI-CIRCUIT, MULTI-CLIENT METERING

The world is changing but our power is constant...

Liebert THE NEW LEADER IN THREE-PHASE UPS PRODUCT. Npower. 30 to 130 kva. True Double Conversion. Exceptional Reliability. Unmatched Performance

Active Harmonic Filter (AHF)

CROSS Chassis from 160 A to 450 A

NGS INVERTER REPLACEMENT SCOPE OF WORK & SPECIFICATIONS

PROTECT 8 INDUSTRIAL UPS. Protect 8.31 Single Phase output 10 kva 80 kva. Protect 8.33 Three Phase output 10 kva 120 kva. Engineering is our business

SECTION THREE-PHASE UNINTERRUPTIBLE POWER SYSTEM

P2 Power Solutions Pvt. Ltd.

UPS Uninterruptible Power System

DCPS Programmable DC Power Supply

AXA 2400 COMPACT & 90 kva solid-state GPU

60K(i) - 260K(i) THREE PHASE. SureImage IMAGING & TREATMENT SERIES

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

DPM - Mesta Electronics, Inc. Low Voltage Active Harmonic Filters

Elgar SmartWave Series VA V A. High Performance AC/DC Power Source. and Boeing standards

Power Processor - Series 700F 10KVA to 150KVA

StatiVolt. Inverter UPS Systems. Features. Contents

GE+ Grid Emulator Plus

Orbital GFI Inverter Series

Minimizing Plant Interruption Caused by Line Disturbances Using Active Voltage Conditioners

Variable Frequency Drive Packages with Harmonic Mitigation. Low Harmonic Drive Packages Engineered by Rockwell Automation

Continental's 816R -5B, 35 kw Single Tube Broadcast Transmitter. Includes the 802A solid -state exciter

GUIDE SPECIFICATIONS 40-80kVA, kVA and kVA Scalable Three-Phase Uninterruptible Power System 1.0 GENERAL

P2 Power Solutions Pvt. Ltd. P2 Power Magnetics. Quality Power within your Reach. An ISO 9001:2008 Company

ZITARES NCD FX-30 Non-SELV (isolated), constant current control gear, 1-channel, dimmable

MT 560/UMT TRANSDUCER & ANALYZER

GE-AC&DC AC&DC Voltage Source

HITEK POWER XR KW X-RAY POWER SUPPLY MODULE

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

DRTS-6. DRTS-6 has been designed to test: DRTS-6. Advanced Protection Relay Test Set and Measurement System

REGENERATIVE GRID SIMULATOR MODEL SERIES MODEL SERIES PRELIMINARY. Regenerative Grid Simulator. Key Features :

USER S MANUAL. 1KSS60400/ ST Edition

Electronic AC Load ZSAC Series. 400 W up to 21,000 W 260 V up to 440 V 3 A up to 100 A. Rev. 3.03

Applications Avionics Testing Power Line Simulation Production Test - Power Supplies - UPS - Telecom. SMARTWAVE Programmable AC/DC Power Source

Power IT LV Active Filters PQFA - PQFL - PQFT

DA850. The all around power DECATHLON

ZITARES NCD FX-30 Non-SELV (isolated), constant current control gear, 1-channel, dimmable

STATIC UNINTERRUPTIBLE POWER SYSTEM Revised 4/30/ Electrical Systems

SC1000 DGPS USCG Dual Transmitter

Est Triplen Power Distribution Unit TPDU kVA

ULTRA RAPID POWER QUALITY ANALYZER

CROMPTON INSTRUMENTS INTEGRA 1222 DIGITAL METERING SYSTEM

Active Harmonic Filter

AC/DC Power Supply Series APPLICATION NOTE

420 W High Line Output Power. Rugged Industrial Construction. -40 C to +70 C Operation. 5 V Standby. Screw Terminals. SEMI F47 Compliant

Switching Power Supply SPECIFICATION

UNINTERRUPTIBLE POWER SUPPLY SPECIFICATIONS MODEL 1100B SERIES

Transcription:

OF CONTINUOUS SERVICE YEARS WARRANTY B9000 FXS 60-300kVA B9600 FXS 400-800kVA

BORRI B9000 FXS B9600 FXS With disturbances to the electrical supply being one of the major causes of IT downtime, the UPS system is regarded as the most critical infrastructure device in the data centre. Interruptions to electrical supply can cost organisations in excess of 100,000 per hour in lost revenues and productivity. The innovative design of the Borri B9000FXS and B9600FXS range makes it one of the most technologically advanced UPS of its kind. Exclusively developed by Borri, the FXS series delivers an advanced combination of low input current distortion, unity power factor input, high overall efficiency and maximum load protection ensuring ultimate power quality. This sophisticated arrangement of features make this series ideal for critical applications where reliability and high performance are fundamental. In addition, the FXS range comprises an IGBT input rectifier design with dual DSP (Digital Signal Processing) and µc (Micro Controller) technologies, which provides full digital control. The FXS configuration guarantees high quality output required by loads requiring a stable and clean source of power, whilst ensuring that auxiliary power supplies and processors are no longer single points of failure as with some other UPS Systems. VFI (Voltage & Frequency Independent) Online Double Conversion topology, provides built-in inverter galvanic protection, completely isolating the output of the UPS from mains power problems and further protection is achieved via an integral output isolation transformer. This advanced design offers an extensive range of user benefits, delivering high efficiency without compromising load protection. > 3 Year Warranty > High Efficiency > Transformer Protection B9000FXS 200-300KVA 3 Year Warranty A 3 year warranty is standard on all Borri B9000FXS and B9600FXS UPS Systems. YEARS WARRANTY We are able to offer such an impressive warranty due to the superior reliability and confidence in our product. To the best of our knowledge no other UPS manufacturer can boast such a lengthy warranty. Not only does this give the user peace of mind but also has the added benefit of reducing on-going maintenance costs. 2

Online Double Conversion Ultimate protection for all loads from data centres to industrial applications, the B9000/B9600FXS incorporates Online Double Conversion or VFI (Voltage and Frequency Independent) topology. In Online Double Conversion mode the output voltage and frequency are constantly generated by the inverter and so are isolated from any input power disturbances, spikes, dips or outages. For maximum protection, the batteries are positioned in the conversion circuit to ensure there is no break or switching should the need arise for them to power the load. This technology allows for an extremely wide range of input voltage and frequency, whilst enabling the UPS to control perfect output conditions without having to use battery power. As the AC input is always converted to DC and then converted back to AC, the double conversion process provides complete electrical isolation of the output from the input, in fact unless the inverter is switched off the critical load will never see the raw mains power UPS Block Diagram w w w. b o r r i. c o. u k 3

Enhanced Compatibility with Mains & Generators The B9000FXS/B9600FXS use an IGBT input rectifier design, encompassing an advanced PFC (Power Factor Correction), which can keep input current THDi (Total Harmonic Distortion of the input) at a level of less than 3% and an input power factor within 1% of unity, even when only small loads are applied. Main benefits for the user: > The installation of the UPS is simplified > Upstream electrical supplies and cables do not have to be heavily overrated to cope with high harmonic distortion B9600FXS 400-800kVA > Standby generators can typically be downsized by 40% > Users can extract more output power from their current supply, increasing load capacity > Efficiency is massively increased - typically 20% > Reduced charges from your energy supplier > THDi <3% with Input power factor >0.99 High Efficiency Dedicated to traditional UPS design, we know that conventional UPS systems operating in true online double conversion mode (VFI) with an output transformer provide the very highest level of protection. Historically this has resulted in poor operating efficiency, however, investment at component level in the design of B9000FXS/B9600 FXS means that the complete range, which has been independently certified by TüV NORD, can perform with overall efficiency levels of greater than 95% through mid-range loadings, in online double conversion mode. This impressive operational rating provides the user with true efficiency without compromise. > Independently certified overall efficiency in excess of 95% at half load running in full online double conversion mode. > Smart online mode efficiency of <98% 4

Transformer Based In keeping with tradition and time proven reliability, the B9000FXS and B9600FXS include an output isolation transformer as standard. The benefit of eliminating the possibility of high DC voltage destroying a valuable data centre in the case of a failing semiconductor, certainly outweighs the small additional footprint required. The transformer increases the overload capabilities, step load performance and short circuit clearing capability and with the addition of a bypass isolation transformer (which produces no losses in normal mode) floating neutrals can be eliminated. High frequency ripple and harmonic distortion of the inverter waveform can also be eliminated with the integration of the transformer with the output AC filter capacitors forms a low-pass filter. B9000FXS / B9600FXS Main Features TüV Certified High Efficiency Online Double Conversion Smart Online Functionality Internal Galvanic Isolation Transformer Front access > Galvanic Isolation between DC and AC. > Additional protection against spikes and surges > Increased performance for step loadings > Reduced harmonics B9000FXS/9600FXS efficiency in excess of 95% at half load Measured Efficiency 97 96 95 94 93 92 91 90 B9600 FXS 500kVA Efficiency Graph B9600FXS 500kVA 0% 25% 50% 75% 100% % Load B9000FXS 60-160kVA w w w. b o r r i. c o. u k 5

Air flow for the B9000FXS/B9600FXS is drawn from the base of the UPS and is exhausted out of the top, this design allows for the UPS to be installed against side or rear walls greatly reducing space. Parallel Offering parallel options for redundancy or capacity modes, the B9600FXS and B9600FXS can add future resilience or scalable growth Up to 8 units can be connected in parallel giving a total scalable power output of 6.4MVA. The FXS series incorporates a fully digital, parallel control circuitry and acts on both active and reactive power on each phase of the UPS outputs. This allows accurate load current sharing among the UPS units even during transient conditions. Parallel control is distributed between all units and communication is achieved through the use of a CAN BUS connection loop. This eliminates any single point of failure within the system and increases reliability. Ultra High Efficiency - Smart Online (SOL) While we advocate that ultimate protection is only achieved whilst operating in online double conversion mode, we also understand that in some situations users will require ultimate efficiency. With this in mind, the FXS series now features smart online mode (SOL). This mode significantly reduces energy consumption as the load is fed primarily through the bypass line. The SOL function continually monitors the input characteristics of the supply and the UPS switches to Inverter within 2mS should the control system experience any anomalies. This mode is perfect for achieving a reduced data centre PUE. Intelligent design of the system connections allow for easy installation and future additions without the need for a power down. In the modular arrangement, units can be added or removed whilst the system is supporting a load. The smart parallel function enables individual units to shut down based on the load applied, delivering optimum efficiency whilst maintaining redundancy. Two independent parallel systems can be synchronised to feed downstream STS for seamless transfers. > 8 units in parallel configuration (up to 6.4MVA) > Output synchronisation of separate parallel systems > Smart parallel with load based shutdown Bypass Easy Installation, Operation and Maintenance The B9000FXS and B9600FXS are designed with only front and roof access for installation and maintenance. This means the units can be installed close to walls and adjacent equipment providing a significant reduction in floor space. As all critical components are accessible from the front of the unit, regular maintenance can be completed with ease. Mains Parallel...n For increased flexibility, the B9600FXS is delivered in modules and assembled upon installation. A maximum width of 1200mm per module ensures a simplified delivery. Load 6

BORRI B9000 FXS Technical Specification POWER - KVA 60kVA 80kVA 100 kva 125kVA 160kVA 200kVA 250kVA 300kVA Capacity (kva) 60 80 100 125 160 200 250 300 Dimensions WxDxH (mm) 815x825x1670 1200x860x1900 Weight (kg) 570 600 630 660 720 970 1080 1200 Input/output connection Battery INPUT Nominal voltage Voltage range Frequency Hardwired (dual input) External, 300 cells 220/380, 230/400, 240/415 VAC Three Phase -20%, +15% from nominal 50/60 Hz (45 65 Hz) Power factor 0.99 Current distortion (THDi) <3% OUTPUT Nominal voltage Frequency Voltage regulation PF acceptable without de-rating Overload capacity Efficiency - Online Double Conversion 220/380, 230/400, 240/415 VAC Three Phase 50/60 Hz ±1% static; ± 5% dynamic 100% load change, <20 ms recovery time Lagging to 0.9 leading 101 125% for 10 min (on-line); 126 150% for 1 min (on-line); 1000% for 1 cycle (bypass) >95% (Certified TUV Nord) Eco-mode - Smart Online 96-98% OPTIONS USER INTERFACE Front panel Standard communication ports Optional ENVIRONMENTAL Operating temperature Storage temperature Altitude Parallel capacity/redundancy; External bypass; Battery thermal probe; Top cable entry Graphical LCD display, mimic with LED s and keyboard RS232 serial port, USB port, Remote Emergency Power Off input, battery switch monitoring port Web/SNMP, ModBus, relay, modem cards; remote panel; monitoring and shutdown software 0 C +40 C -10 C +70 C <1000 m Audible noise at 1 meter (dba) <60 STANDARDS & CERTIFICATION Marking CE, GOST, ETL, TUV Safety IEC EN 62040-1 EMC IEC EN 62040-2 Test and Performance IEC EN 62040-3 Quality; Environment ISO9001: 2008, ISO14001: 2007 Health & Safety BS OHSAS, 18001: 2007 B9000FXS 60-160kVA B9000FXS 200-300kVA w w w. b o r r i. c o. u k 7

BORRI B9600 FXS Technical Specification POWER - KVA 400kVA 500kVA 600kVA 800kVA Capacity (kva) 400 500 600 800 Dimensions WxDxH (mm) 1990x990x1920 2440x990x2020 3640 x 990 x 1920 Weight (kg) 1820 2220 2400 3600 Input/output connection Hardwired (dual input) Battery External, 300 cells INPUT Nominal voltage 220/380, 230/400, 240/415 VAC Three Phase Voltage range -20%, +15% from nominal Frequency 50/60 Hz (45 65 Hz) Power factor 0.99 Current distortion (THDi) <3% OUTPUT Nominal voltage 220/380, 230/400, 240/415 VAC Three Phase Frequency 50/60 Hz Voltage regulation ±1% static; ± 5% dynamic 100% load change, <20 ms recovery time PF acceptable without de-rating Lagging to 0.9 leading Overload capacity 101 125% for 10 min (on-line); 126 150% for 1 min (on-line); 1000% for 1 cycle (bypass) Efficiency - Online Double Conversion >95% (Certified TUV Nord) Eco-mode - Smart Online 96-98% OPTIONS Parallel capacity/redundancy; External bypass; Battery thermal probe; Top cable entry USER INTERFACE Front panel Graphical LCD display, mimic with LED s and keyboard Standard communication ports RS232 serial port, USB port, Remote Emergency Power Off input, battery switch monitoring port Optional Web/SNMP, ModBus, relay, modem cards; remote panel; monitoring and shutdown software ENVIRONMENTAL Operating temperature 0 C +40 C Storage temperature -10 C +70 C Altitude <1000 m Audible noise at 1 meter (dba) <60 STANDARDS & CERTIFICATION Marking CE, GOST, ETL, TUV Safety IEC EN 62040-1 EMC IEC EN 62040-2 Test and Performance IEC EN 62040-3 Quality; Environment ISO9001: 2008, ISO14001: 2007 Health & Safety BS OHSAS, 18001: 2007 The data and text contained within this brochure are for general information only and can not be deemed as definitive, specifications can change without notice. B9600FXS 400kVA B9600FXS 500-600kVA B9600FXS 800kVA BORRI LTD Systems House Rotherside Road Eckington Sheffield S21 4HL Tel: +44 (0)1246 431431 Fax: +44 (0)1246 431444 Email: sales@borri.co.uk Web: www.borri.co.uk BORRI S.p.A Via 8 Marzo, 2 52010 Bibbiena (Arezzo) Italy Tel: +39 0575 5351 Fax: +39 0575 561438 Email: info@borri.it Web: www.borri.it