OPERATING MANUAL SERIES R B F BRUSHLESS RACK SYSTEM

Similar documents
OPERATING MANUAL SERIES R B F 400 VAC BRUSHLESS RACK SYSTEM

OPERATING MANUAL SERIES SMTBM BRUSHLESS SINGLE AXIS MODULE

MASTER/SLAVE TENSION CONTROL

STEPPING MOTOR EMULATION

CD1-p Installation manual gb PROFIBUS POSITIONER INFRANOR. CD1-p 1

S100A40AC SERIES BRUSHLESS SERVO AMPLIFIERS Model: S100A40AC

Scroll down to view your document!

IC800SSD Hardware Manual Pub 348R5. for models. A publication of

SMT-BD2 DIGITAL SERVO DRIVE FOR SINUSOIDAL BRUSHLESS AC MOTORS SMT-BD2

CD1-k Installation Guide. XtrapulsCD1-k Installation Guide. CANopen drive

SMT-BD2/m. SMT-BD2/m gb POSITIONER FOR SINUSOIDAL BRUSHLESS LINEAR AND ROTATING AC MOTORS

WINDING/UNWINDING TENSION CONTROL

PWM SERVO CONTROLLERS SERIES MRM

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

SMT-BD1/m gb. SMT-BD1/m Positioner. See addendum at the end of the manual regarding the drives delivered with the Eprom version 7.

CD1-pm Installation manual gb PROFIBUS POSITIONER INFRANOR. CD1-pm 1

IMC-316P Hardware Manual for model IMC-316P-X-D

The Allen-Bradley Servo Interface Module (Cat. No SF1) when used with the Micro Controller (Cat. No UC1) can control single axis

200 Watt Passive Shunt Module

INSTALLATION MANUAL NE2110, NE2120 D.C. SERVO CONTROLLERS

TC1028 series. Thyristor units. Control of single-phase resistive or inductive loads. User manual (300A to 500A rated units)

Amplifier Series BASIC. Installation & Operations Manual

SMT-BD1 gb. SMT-BD1 digital drive for AC sinusoidal synchronous motors SMT-BD1 1

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3

LC31L-BAT Link Coupler

MTY (81)

Instruction Kit MIXER AMPLIFIER GT 60C GT 125C. GROMMES-PRECISION SINCE-46

Npaq Series Drive Racks

Digital Lighting Systems, Inc. PD804-DMX. Eight Channel DMX Pack. (includes information for PD804-DMX-S) USER'S MANUAL. PD804-DMX-UM Rev.

CD1-a gb. CD1-a digital drive for AC sinusoidal brushless motors. CD1-a 1

An RS485 bus is used for command, monitoring and diagnostic information that can be supplied to a system controller.

INSTALLATION AND OPERATING INSTRUCTIONS MODEL SIVF. KB Part No Signal Isolator for KBVF Controls. See Page 1 Pending

B25A20FAC SERIES BRUSHLESS SERVO AMPLIFIERS Model: B25A20FAC 120VAC Single Supply Operation

CHAPTER 3 WIRING DANGER

Analog Servo Drive. Peak Current 16 A (11.3 A RMS )

LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING

FEATURES DESCRIPTION THE OEM ADVANTAGE

CONTENTS XV300K GB r doc XV300K 2/13

815-BR SERVO AMPLIFIER FOR BRUSH SERVOMOTORS

I. h y fe. DR Series Drive Racks. Plug-in drives. Rack-mount design. Brush, brushless, or stepper. Variety of amplifier power. Integral power supply

Analog Servo Drive. Continuous Current. Features

24V dc Analog Block I/O Module

CCH400 & CCH600 Series

Industrial PSU with universal input voltage range ( VAC line to line) and configurable output voltage. North America

MGA Magnetic field system. DC khz

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

ASX SERIES PACIFIC OPERATION MANUAL AC POWER SOURCE POWER SOURCE

2.2 American National Standards Institute Corporation and its applicable standards C39.1, C80.1, C89, C84.1.

Model FM350 FM Broadcast Pallet Amplifier

Assembly Instructions for the 1.5 Watt Amplifier Kit

8V General information. 2 Order data 8V

Analog Servo Drive 30A20AC

SMT-BD1-400/I gb. Digital amplifier for 400 VAC sinusoidal brushless motor SMT-BD1-400/I 1

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz

MTY (81)

Electronic Circuit Breaker with reset input ESS20-1..

USER MANUAL. MODEL 2017A RS-232 to 20ma Current Loop Converter. SALES OFFICE (301) TECHNICAL SUPPORT (301)

CMP-300 Composite Mixer/ Distribution Amplifier

Creating Electrical Designs

Analog Servo Drive 100A40

DANFYSIK A/S - DK-4040 JYLLINGE - DENMARK

Q-Tech. Q-Tech Commercial Series QTA 1360P/1480P Power Amplifiers. User Manual

Npaq 6U Series. High-Power Drive Racks. High-power 6U modular drive chassis. 19 inch rack-mount design

POWER AMPLIFIER. Owner s Manual Mode d emploi Bedienungsanleitung Manual de instrucciónes CLIP SIGNAL TEMP PROTECTION POWER

XtrapulsPac User Guide en. Digital drive for sinusoidal synchronous AC motors. XtrapulsPac Installation Guide Preliminary edition 1

This manual describes the option "i" of the SMT-BD1 amplifier: Tension control of winding / unwinding systems.

411LA Broadband Power Amplifier

Product overview. Features. Product specifications. Order codes. 1kΩ Resistance Output Module

MODEL 25D MANUAL PRODUCT OVERVIEW:

MCTS II Multi Channel Current Transducer System. Installation Manual

Peak Current. Continuous Current. See Part Numbering Information on last page of datasheet for additional ordering options.

8 Input/8 Output AC Block I/O Module

3U High, 19" Drive Rack

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

Current / residual current and voltage transformers. Current / residual current and voltage transformers

PIC SERIES. Installation and Operating Manual. Elmo Motion Control. Rev.: 05/99

High Frequency SineWave Guardian TM Filter

PLUG N PLAY WATT DIGITAL FM TRANSMITTER. April, 2002 IM No

TECHNICAL MANUAL. SERIES AP5202 DC Strain Gage In-Line Amplifier ISO 9001/AS9100

Installation Tech Note Dallas, Texas

1) The diagrams in the section Assembly notes were provided by Rittal GmbH Co. KG, Herborn and by Invensys Systems GmbH EUROTHERM, Limburg/ Lahn.

Device Interconnection

PERFORMANCE AMPLIFIER II OWNERS MANUAL. Serial Number

Contents NUDRIVE ACCESSORY USER GUIDE

Ndrive Series. Digital Servo Amplifiers PWM. Wide output power range from 10 A peak to 200 A peak at 320 VDC. 2- or 3-phase AC line input or DC input

DSM Dynamic Shunt

INSTALLATION AND OPERATION MANUAL IODA INPUT/OUTPUT MULTI-FUNCTION BOARD (Part No. 9668)

PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian)

MX Drives User s Guide Addendum #5 CE-Marked Drive Installation

Integrated servo motor

INSTRUCTIONS YASKAWA. Upon receipt of the product and prior to initial operation, read these instructions thoroughly, and retain for future reference.

UP-67M4, UP-127M4, UP-247M2, UP-487

SPA1000 kit Power Amplifier kit - Assembly Guide

Ameritron RCS-10 INTRODUCTION

INSTRUCTION MANUAL. March 11, 2003, Revision 3

Power Supplies 3. SDN-C Compact DIN Rail Series

High Frequency Sinewave Guardian TM Filter

Resilient 3000 EP3000AC48IN Rectifier 3000W Output at 48 58Vdc

R10-FA-01 Ruggedized Edge Filter for Xenus: User Guide

Electronic amplifier for the control of proportional valves without position control Model VT 3006, Series 3X H/A 4240/94 VT X

Transcription:

OPERATING MANUAL SERIES R B F BRUSHLESS RACK SYSTEM Version 3.0 (European version 1.3) This is a general manual describing a series of racks receiving Servo Amplifiers having output capability suitable for driving Brushless Servo Motors. This manual may be used in conjunction with appropriate and referenced drawings pertaining to the various specific models. Maintenance procedures should be attempted only by highly skilled technicians using proper test equipment. Read your warranty provision carefully before attempting to adjust or service the unit.

RECEIVING AND HANDLING Upon delivery of the equipment, inspect the shipping containers and contents for indications of damages incurred in transit. If any of the items specified in the bill of lading are damaged, or the quantity is incorrect, do not accept them until the freight or express agent makes an appropriate notation on your freight bill or express receipt. Claims for loss or damage in shipment must not be deducted from your invoice, nor should payment be withheld pending adjustment of any such claims. Store the equipment in a clean, dry area. It is advisable to leave the equipment in its shipping container until ready for use. Each amplifier is checked carefully before shipment. However, upon receipt, the user should make sure that the amplifier received corresponds to or is properly rated in terms of rated voltage and current for the type of motor which is to be driven. The descriptive label affixed to the amplifier specifies electrical ratings. Infranor Inc. reserves the right to change any information contained in this manual without notice. Infranor Inc. does not assume any responsibilities for any errors that may appear. 1998 INFRANOR INC. 2

OPERATING MANUAL INFRANOR SERIES RBF BRUSHLESS RACK SYSTEM (March 1998) 1.0.0 GENERAL... 4 1.1.0 INTRODUCTION... 4 1.2.0 SPECIAL FEATURES... 4 2.0.0 SPECIFICATIONS... 4 2.1.0 TECHNICAL SPECIFICATIONS FOR RBF RACK SERIES... 4 2.2.0 TECHNICAL SPECIFICATIONS FOR SHUNT REGULATOR... 6 2.3.0 AMPLIFIER CURRENT TABLE FOR CONTINUOUS CYCLE... 7 3.0.0 CONNECTIONS... 8 3.1.0 PRINCIPLES... 8 3.2.0 RBF BACK PANEL CONNECTIONS... 9 3.3.0 POWER CONNECTIONS... 11 3.4.0 THREE PHASE CONNECTION VIA AUTOTRANSFORMER... 13 3.5.0 THREE PHASE CONNECTION WITHOUT AUTOTRANSFORMER... 15 3.6.0 SINGLE PHASE CONNECTION WITHOUT AUTOTRANSFORMER... 16 4.0.0 DIMENSIONS... 17 4.1.0 AMPLIFIER DIMENSIONS... 17 4.2.0 RBF RACK DIMENSIONS... 17 4.3.0 LINE FILTER DIMENSIONS BF35 - BF70... 17 4.4.0 LINE REACTANCE DIMENSIONS... 19 4.5.0 AUTOTRANSFORMER DIMENSIONS... 20 4.6.0 D1 SHUNT REGULATOR DIMENSIONS (IN MM)... 20 4.7.0 SHIELDING RECOMMENDATIONS... 21 3

1.0.0 GENERAL 1.1.0 Introduction The RBF rack system is designed for the Infranor brushless amplifier SMTBSI and SMTBD Series independently of the different amplifier current rating. The power bus voltage is floating and is not connected to the chassis, therefore allowing a transformerless operation. The power supply is integrated into the rack on the left side flange which act as an heat sink. Motor and power supply connections are in the rear of the rack for better noise immunity. A shunt regulator system is also part of the power supply. Four different power dissipations are available, depending upon the energy regenerated by the system. 1.2.0 Special features 6 axis in a standard 19" rack, height = 355mm, depth = 285mm. 35ADC or 70ADC DC bus power supply available. (90ADC on request) Transformerless operation (inductors may be required) Fan cooling for optimum heat dissipation. Optional shunt regulator modules available. Rear rack mounting. Easy amplifier plug-in connections. Terminal strip connector over the rack. Standard auxiliary input voltage for logic supply. 2.0.0 SPECIFICATIONS 2.1.0 Technical specifications for RBF Rack Series The RBF rack Series can accept up to 6 axis (<60ARMS) including one DC bus power supply. Depending upon the amplifier maximum continuous current, it will be necessary to allocate one and half or two axis for one module due to a larger heat sink size: Main Power Supply < = 60 ARMS = 1 Axis width < = 60 ARMS with heatsink = 1.5 Axis width > = 70 ARMS = 2 Axis width The main DC power supply has a rating of 35 ADC or 70 ADC. It will be necessary to calculate the continuous rms current of the overall system in order to properly size the current rating. An optional 90ADC power supply is available on special request. The use of an isolation transformer is not necessary, however, an autotransformer can be used to step up/down the voltage. A line inductor will be mandatory if direct line (220VAC) is used. 4

Rated input voltage 3Ø 220VAC 50/60 Hz Maximum input voltage 240 VAC + 10% Minimum input voltage 100 VAC Maximum wire gauge 6 AWG The total line impedance must limit in rush current to 650 A for a 35 ADC supply and 1100 A for a 70 ADC supply. Auxiliary Supply When position interface is used, the position information can be lost if power failure occurs. By applying a separate logic voltage (220VAC single phase), it will retain position information even if main power supply fails. The auxiliary supply input is also used when fan(s) are mounted on the rack chassis Rated input voltage 1Ø 220VAC 50/60 Hz Maximum input voltage 240 VAC + 10% Minimum input voltage 200 VAC - 10% Logic Signals Some logic signals are available on the rear of the rack by the mean of eight pin connector. They can be used for common logic signals to all amplifiers as follows: "Inhibit" common to all axis "Power ready and D/R Resistor OK" common to all axis "Amp ready" common to all axis "Idyn" common to all axis In standard all axis signals are in series, but can be set independently from each other by means of jumpers (See chapter 3.20). Designation of RBF Rack Series RBF - / - - Power Supply 35A D 140W Power Supply 70A D2 280W Power Supply 90A E 560W External D1 1100W External Rack width 36TE = 239mm 2 including 48TE = 300mm 3 power supply 60TE = 361mm 4 Axis Position (12TE) 72TE = 422mm 5 0 Axis of 1 spacing (12TE) 84TE = 483mm 6 1 Axis of 1.5 spacing (18TE) 2 Axis of 2 spacing (24TE) 5

Note: Amplifier with current higher than 60Arms require a width of 2 axis. A heatsink can be mounted on the amplifier module increasing the width to 18TE. A fan is required depending upon the amplifier RMS current rating. They are mounted on top of the rack. One fan can cool up to 2 axis of 60A and smaller or 1 axis of 70A and higher. The input voltage is applied to the auxiliary supply input (XA2). 2.2.0 Technical specifications for shunt regulator Several shunt regulator circuits are available, depending on the energy regenerated by the system. We do recommend to consult Infranor for proper sizing of this device. Four shunt regulators can be integrated with the RBF rack series as follows: Type Continuous Power Peak Power Shunt Resistors RBF 35 RBF 70 RBF 90 D 140 10000 inside STD NA NA D2 280 16000 side flange OPT STD STD E 560 20000 external resistors NA OPT OPT D1 1100 42000 external resistors NA OPT OPT Type D: A resistor of 15Ω /140W is mounted on the inner left side flange of the RBF rack. This version is standard if not specify otherwise on the RBF-35 rack version. Type D2: A resistor of 10Ω / 280W is mounted on the outer left side flange of the rack with a finger guard cover. The overall width of the RBF rack will increase by about 30mm (1.2in). This version is standard if not specify otherwise on the RBF-70 rack version. Type E: Two resistors of 15Ω / 280W are mounted by the customer via two connectors placed on the rear of the rack. An IGBT transistor is used allowing higher dissipated power. These resistors have to be wired in parallel to allow a dissipation of 560W continuous. Type D1: This model is made of two braking systems type E connected via three connector on the rear of the rack. It is suggested to mount this assembly outside the electrical cabinet to allow proper cooling. See chapter 4.6.0 for dimensions 6

2.3.0 Amplifier current table for continuous cycle MODEL IMAX 1sec Un Veff SMTBD SMTBSI Inom (Aeff) WITHOUT FAN FAN 1 FAN 2 SIZE SMT-BSI-220/08 240 8.8 8 4 12TE SMT-BSI-220/12 240 13.8 13 6 12TE SMT-BSI-220/17 240 17.7 17 8,5 12TE SMT-BSI-220/30 240 30.8 29 8,5 12 15 12TE SMT-BSI-220/30r 240 30.8 29 10 15 18TE SMT-BSI-220/45 240 48.6 46 8,5 15 18 12TE SMT-BSI-220/45r 240 48.6 46 10 20 23 18TE SMT-BSI-220/60 240 61 58 8,5 17 20 12TE SMT-BSI-220/60r 240 61 58 12 26 30 18TE SMT-BSI-220/70¹ 240 70 70 17 30 35 24TE SMT-BSI-220/100¹ 240 100 100 25 30 35 24TE ¹Mechanical width is double (24TE) Fan 1 = 115CFM Fan 2 = 220CFM Note: The models with an r are equipped with an heatsink, therefore the mechanical width is increased from 12TE to 18TE (see chapter 4.1.0 for dimensions) 7

3.0.0 CONNECTIONS 3.1.0 Principles It is very important to follow some precautions to avoid ground loops around the zero volt logic supply or noise disturbances in order to obtain good results. Here are a few points to pay special attention: Every conductor cable (carrying a potential) MUST be shielded. Two or more wires in the same sleeve MUST be twisted pair and shielded. A shield not carrying a potential can be connected at both ends with a 360º clamp connection (shield to be connected over the whole circumference of the cable by a clamp). The reference of potential IS connected to earth ground. Cable with low potential should NEVER run in the proximity of power lines. Long reference potential leads is suitable ONLY if these loops have a very low impedance (<0.1 ohm). A shielded cable has NO effect if it is not connected: to a reference potential by a short length to a reference potential (few inches) by a 360º shielded connection. If a reference of potential is existing like a main chassis or a cabinet with a low impedance between the different elements of its volume, it should be used to connect all reference to it and also connect this reference to the earth. 8

3.2.0 RBF back panel connections JUMPER INHIBIT AMP. READY IDYN (option) "A" closed on last axis Serial Switches G and H ON "A" closed on each axis Independent Switches G and H OFF "B" closed on last axis Switches E and F ON "B" closed on each axis Switches E and F OFF "N" closed on last axis Switches O and P ON "N" closed on each axis Switches O and P OFF Switch D ON Serial Serial Independent POWER OK D/R OK Serial Independent only available on connector X5 Switch D OFF Independent In standard, all these signals are wired in series. Consequently, the jumpers A, N, B are closed on the last axis 3.2.1 X5 - Common signals connector (8 points orange) Pin Function Remarks 1 Common Inhibit Enable to 0 Volt, disable if open 2 0 Volt Inhibit 3 Power ready + D/R OK All relay contacts of each axis in series 4 Power ready + D/R OK if one fails, relay opens 5 Amplifier ready All relay contacts of each axis in series 6 Amplifier ready if one fails, relay opens 7 Idyn limitation (option) All relay contacts of each axis in series 8 Idyn limitation (option) if Idyn limitation occurs, contact relay opens See amplifier operating manuals for more details on the function of these signals. Relay output specifications is rated at 50V, 100mA 9

3.2.2 RBF back panel diagram X5 8 1 D O P E F G H D O P E F G H B B B A A A N N N 01624 01624 01624 BACK PANEL 12TE X5 8 1 X5 8 1 B B A A N N 01625 01626 10 BACK PANEL 18TE BACK PANEL 24TE

3.3.0 Power connections XA1 X MOT X MOT XA2 X5 POWER SUPPLY AXIS 1 AXIS 2 AXIS n 3.3.1 Power supply connector XA1 - XA2 The power supply connector includes the main line input XA1, the auxiliary and/or fan(s) input XA2 and the connections for the braking resistor(s) according to the option (D1 or E option). 3 phase 220 VAC XA1 Maximum section: 16 mm2 (AWG 6) Maximum continuous current: 82 A 1 2 3 L1 L2 L3 Earth/Ground: Screw 5 mm XA2 1 2 3 4 5 Resistor option D1 220 VAC Auxiliary supply Fan(s) supply Resistor option E and D1 11

3.3.2 Motor connection EACH MOTOR HOUSING MUST BE CONNECTED TO EARTH GROUND (resistance <0.1 ohms). These connections must be independent of the main power supply voltage. Motor cables must be shielded to avoid the effects of common mode. The recommended cable is a four wires shielded (Mavilor p/n 410-0051, 410-0052, Belden p/n 9367). Each motor shield must have a "360 " connection on the motor connector side AND on the clamp provided in the Infranor rack chassis. This will be in accordance with the electromagnetic requirement of IEC 801. The motor cable cannot run in the proximity of the resolver or command cables. The motor cable gauge must be adapted to the rating of the amplifier continuous current. Motor cable Motor cable shield Shield clamping collar over 360 degrees or cable tie Ground screw 4mm Motor connector U V W Maximum section: 6 mm² (AWG 10) Maximum continuous current: 44 Arms 12

3.4.0 Three phase connection via autotransformer The main three phase input line voltage is rated at 220 VAC, therefore an autotransformer or an isolation transformer is required if other voltage are available at the main line voltage. Contact Infranor Inc for appropriate transformer sizing. The auxiliary voltage must ALWAYS be connected between two of the 220 VAC line phase (see diagram below). MAIN LINE THREE PHASE AUTO Power relay M TRANSFORMER 3 x 220 VAC.. Optional for CE see chapter 3.4.1 LINE FILTER BF35/70 XA1 1 2 3 L1 L2 L3 X MOTOR Fuses RBF RACK XA2 1 2 Fuses 2AT Logic relay Chassis reference potential All supply line voltage must ABSOLUTELY be connected through a relay contactor to cut all lines at the same time (main power and auxiliary supply). The logic relay MUST BE activated before the power relay (minimum 2sec.) The grounding of the RBF rack is MANDATORY in order to avoid any physical damages in case of insulation failure. Infranor recommend the use of a differential circuit breaker to control any insulation failure to earth ground. See chapter 4.5.0 for autotransformer specifications and dimensions. 13

3.4.1 Main line three phase filter In order to comply with the electromagnetic standard EN 55011 group 1 class A with autotransformer usage and the CE specifications, it is necessary to add a three phase line filter as shown in diagram chapter 3.4.0. The two curves below shows the frequency response without line filter (curve no. 11 ) and with line filter (curve no. 26). Curve no.11 Curve no.26 14 The line filter must be connected as close as possible to the RBF rack (max. 30cm). A metal braid must connect the filter ground terminal to a fastening screw of the RBF rack to maintain equipotentiality. Two current rating line filter are available, that is the BF35 for the RBF-35 and the BF70 for the RBF-70.

3.5.0 Three phase connection without autotransformer Where a 220 VAC main line voltage is available, it is possible to connect the RBF rack directly to the main line. However to limit the in-rush current, it is MANDATORY to use a three phase line inductor. The auxiliary voltage must ALWAYS be connected between two of the 220 VAC line phase (see diagram below). MAIN LINE 3 x 220 VAC.. LINE INDUCTOR Power relay M 3 x 220 VAC Optional for CE see chapter 3.4.1 LINE FILTER XA1 1 2 L1 L2 X MOTOR BF35/70 3 L3 Fuses RBF RACK XA2 1 2 Fuses 2AT Logic relay Chassis reference potential All supply line voltage must ABSOLUTELY be connected through a relay contactor to cut all lines at the same time (main power and auxiliary supply). The logic relay MUST BE activated before the power relay (minimum 2sec.) The grounding of the RBF rack is MANDATORY in order to avoid any physical damages in case of insulation failure. Infranor recommend the use of a differential circuit breaker to control any insulation failure to earth ground. See chapter 4.4.0 for three phase line reactor specifications and dimensions. 15

3.6.0 Single phase connection without autotransformer Single phase connection directly into the 220 VAC main line is also possible where the maximum continuous current do not exceed 20 ADC (14 Arms). It is MANDATORY to add a single phase line inductor as for the three phase connection. The auxiliary voltage must ALWAYS be connected between two of the 220 VAC line phase (see diagram below). MAIN LINE. 220 VAC LINE INDUCTOR. Power relay M 220 VAC XA1 X MOTOR Fuses 1 2 3 XA2 1 L1 L2 L3 RBF RACK 2 Fuses 2AT Logic relay Chassis reference potential All supply line voltage must ABSOLUTELY be connected through a relay contactor to cut all lines at the same time (main power and auxiliary supply). The logic relay MUST BE activated before the power relay (minimum 2sec.) The grounding of the RBF rack is MANDATORY in order to avoid any physical damages in case of insulation failure. Infranor recommend the use of a differential circuit breaker to control any insulation failure to earth ground. See chapter 4.4.0 for single phase line reactor specifications and dimensions. 16

4.0.0 DIMENSIONS 4.1.0 Amplifier dimensions 233,4 mm 24 TE 18 TE 12 TE 220 mm 4.2.0 RBF rack dimensions 90 mm 80 mm 266 mm 286 mm Axis Modules SMTB # of 2 3 4 5 6 DIMENSION "A" inches 7.2 9.6 12.0 14.4 16.8 millimeters 182.9 243.8 304.8 365.7 426.7 DIMENSION "B" inches 8.71 11.11 13.51 15.91 18.31 millimeters 221.3 282.2 343.2 404.1 465.1 DIMENSION "C" inches 9.41 11.81 14.21 16.61 19.0 millimeters 239.2 300.1 361.1 422.1 483.0 36TE 48TE 60TE 72TE 84TE 4.3.0 Line filter dimensions BF35 - BF70 17

40 36 60 229 73 8495 1,5 MAINS L1 L2 L3 88 7 = = 5 L1 L2 L3 218 LOAD 18

4.4.0 Line reactance dimensions 4.4.1 Three phase line reactance (60Hz) W H D CONNECTORS MD MW MODEL RACK CURRENT H W D MW DW LBS. I3-2435 RBF-35 35A 7.5 7.25 5.0 4.82 3.13 18 I3-2480 RBF-70 70A 9 9 6 6 4 34 Dimensions are in inches 4.4.2 Single phase line reactance (60Hz) W H D CONNECTORS MD MW MODEL RACK CURRENT H W D MW DW LBS. I1-2420 SMTBM-20A 20A 3.50 4.13 3.50 3.44 2.63 8 RBF-35* * Total RMS current lower than 14Arms Dimensions are in inches 19

4.5.0 Autotransformer dimensions W H D CONNECTORS MD MW Three phase autotransformer 60Hz Temperature Class H, 155 Degree C Insulation Class N, 200 Degree C Open frame MODEL PRIMARY SECONDARY KVA H W D MW DW VOLTAGE VOLTAGE ATR3-2000-600-220 480/600 220 2 9.75 8.75 5.00 4.00 4.00 ATR3-3000-600-220 480/600 220 3 9.75 8.75 5.75 4.00 4.25 ATR3-4000-600-220 480/600 220 4 9.75 11.00 5.50 9.00 3.94 ATR3-5000-600-220 480/600 220 5 9.75 11.00 6.50 9.00 4.87 ATR3-7000-600-220 480/600 220 7 9.75 11.00 7.00 9.00 5.37 Dimensions are in inches 4.6.0 D1 shunt regulator dimensions (in mm) 250 234 102 108 450 234 20

4.7.0 Shielding recommendations There must never be a shield interruption on the whole cable length. Self-sticking copper ribbon if necessary for increasing the shield diameter to get properly tightened under the clamp Connector on MAVILOR motor for resolver and motor RBF RACK The cable can be soldered on the shield because the connector box is metalic This solution does not correspond exactly to the IEC requirements, but it is acceptable Connector box on the MAVILOR motor Metallic or metal plated plastic Sub-D pin package 360 degrees shield ensured by the tightening clamp Sub-D connector The fastening screw must be tightened in order to ensure the shield continuity on the amplifier housing Note: When the 360 degrees shield is made by means of a clamp, it is not necessary to connect a wire to the appropriate pin on the Sub-D connector. 21