Nivotester FTR325. Technical Information. 1-channel switch amplifier for the Soliwave M microwave barrier

Similar documents
Nivotester FTR325. Technical Information. 1-channel switch amplifier for the microwave barrier Soliwave FDR50/FQR50

Soliwave M FQR50 / FDR50

Level Limit Switch nivotester FTL 325 P

Level Limit Switch nivotester FTL 370, FTL 372

Remote Switching Unit nivotester FTL 320

SET Installation and Operating Instructions. Level switch for two sensors

Level Measurement silometer FMX 570

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

Technical Information Nivector FTC968, FTC968Z

Temperature Input Module for Zone 1 Series 9482/32

itemp HART DIN rail TMT112

Temperature transmitter itemp PCP DIN rail TMT 121

Soliwave FQR56/FDR56. Technical Information. Microwave Barrier. FQR56 emitter. FDR56 receiver

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Temperature Transmitter itemp RTD DIN rail TMT 127

Data Sheet KFD2-UFC-EX1.D. Supplied by. .com. Call us on +44 (0)

RMA42. Technical Information

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

Inductive sensor slot-type SI2-K08-AP7

INSTALLATION AND OPERATION MANUAL

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Digital temperature transmitter Model T15.H, head mounting version Model T15.R, rail mounting version

Analog Universal Module HART for Zone 2 Series 9468/33

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

Isolators Isolating Repeater Field Circuit Ex i ISpac 9165/ s Art. No

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

itemp PA TMT184 Technical information

0 2 1 â Ó. itemp HART TMT182. Technical Information

RAD-IN/OUT-8D. Digital extension modules for the bidirectional wireless system. INTERFACE Data sheet _en_05. 1 Description

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

06528E00. ATEX / IECEx NEC 505 NEC 506 NEC 500

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

DIN Rail Devices. CEAG Sicherheitstechnik GmbH 194

SBEx-2S BINARY SEPARATOR

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Operating Instructions

Safety Instructions Nivotester FTC625, FTC325

Isolators A3/1. Vibration Transducer Supply Unit Series

Connection. Input EEx ia IIC. Input I. Input II R 1 R 1 A B A 2+ B LB SC. yellow. red. Composition

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

SALES SERVICE +358 (0)

Digital Input Output Module for Zone 2 Series 9470/33

PRetrans Table of contents

09746E00. ATEX / IECEx NEC 505 NEC 506 NEC 500 Class I Class I Class II Class III Zone Zone Division Ex i

Installation guide 971 SmartRadar LTi

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

Liquiphant M/S with electronic insert FEL57 + Nivotester FTL325P

Operating Instructions

Target disk flowmeters Series DP Metallic flowmeter for liquids and gases

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC

Installation and Operating Instructions Differential pressure transmitter for potentially explosive areas. MG-1000-EEx USAGE STRUCTURE AND DESIGN

Technical Information Barrier RB223

OPTITEMP TT 10 C/R Technical Datasheet

2 Safety Barriers. Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

Technical Information RMA42

Target disk flowmeter for liquids and gases

... for hydraulic and general applications in hazardous areas

Remote I/O. 74 Remote I/O. Remote I/O System

Design and applications

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

MJK Expert 700 / 800 / 900 / 1100 / 2100 MJK Expert 1400 / 3400

Isolators A3/1.

OPTIWAVE 7300 C Supplementary instructions

TVA 080 / 100 / 120 / 180 / 200 / 220 Isolation amplifier active

Level Limit Measuring System liquiphant M/S with FEL 56 + nivotester FTL 325 N

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Level and Pressure. Product Information. Vibrating level switches

Local control stations for Zone 1 and Zone 21. Features. Description

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

Endress Hauser The Power of Know How. Turbidity and Solids Content Sensor TurbiMax P CUS 63 / CUS 63H

Binary Output Series 9175

System Components Liquiphant M (NAMUR)/PROFIBUS-PA interface FXA 164

SINEAX TI 807 Passive DC signal isolator

Weighing Instruments. Applications. Characteristics. DMS strain gauges (load cells), DMS amplifier

QUINT-PS/ 3AC/24DC/10

Single-Channel Safety Barriers with Electronic Current Limitation Series 9004

PROline promag 53 Division 1

Operating Instruction

Digital Input Output Module for Zone 1 Series 9470/32

KFS. Flap-type flow meter. Design and range of application

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

SITRANS F flowmeters SITRANS F US. SONOFLO SONO 3000 transmitter. 4/152 Siemens FI Overview

ICARUS ELECTRONIC GAS VOLUME CONVERTER

2-WiRE LEvEL TRansmiTTER PRELEvEL 5343 ConTEnTs

Description. Annexe to: IECEx CML X Issue 1. Isolating Amplifier D461

EMD-FL-C-10. Current Monitoring Relay. Data Sheet. Functions. Structure 08/2004

Hydrostatic Level Measurement silometer FMB 672 Z, FMB 677 Z

Weighing Instruments

Resistance thermometer Model TR30, compact design

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

Assembly. Front view. Power Rail

Current / residual current and voltage transformers. Current / residual current and voltage transformers

Digital Input Output Module for Zone 2 Series 9470/33

Isolators A3/1.

3 Ex i Isolators. Temperature Transmitter without Output 0/ ma, with Limit Value Contact (Field Circuit Ex i) Type 9182/.

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Transcription:

Technical Information Nivotester FTR325 1-channel switch amplifier for the Soliwave M microwave barrier Area of application The Nivotester FTR325 is suitable as a 1-channel switch amplifier for the Soliwave M microwave barrier. You can use the FTR325 for level detection for any type of solids or for control and counting tasks for packaged goods. Associated apparatus for the microwave barrier with intrinsically safe circuits (FQR50/FDR50-C*). Advantages at a glance High level of operational safety through line monitoring up to the sensor LED display of operating and switching state Selectable pick up and/or drop out delay of the switching output Compact housing for easy inline mounting on standard rack rails Easy wiring via pluggable terminal block connectors TI377F/97/en/11.07

Table of contents Function and system design... 3 Measuring principle... 3 Limit switch signal function... 3 Function monitoring system... 3 Measuring system... 4 Characteristics... 5 Measured value... 5 Input signal... 5 Output signal... 5 Auxiliary energy... 5 Supply voltage... 5 Accessories... 14 Protective housing... 14 Certificates and approvals... 15 CE symbol... 15 Ex approval... 15 External standards and directives... 15 Supplementary documentation... 15 Operating instructions (KA)... 15 Technical informations... 15 Safety instructions... 15 Electrical connection... 6 Connecting cable... 6 Wiring... 6 Ring wiring... 7 Stern wiring... 7 Controls and instrumentation... 8 Control concept... 8 Indicators... 8 Control elements... 8 Operating conditions... 10 Installation location... 10 Ambient conditions... 10 Protection type (according to EN 60529)... 10 Safety instructions... 11 Installation... 11 Safety notes for electrical equipment in Ex-areas... 11 Mechanical constructions... 12 Structure shape... 12 Materials... 12 Clearances... 12 Dimensions... 12 Ordering information... 13 Ordering information Nivotester FTR325... 13 Designation... 13 Nameplate... 13 2

Function and system design Measuring principle The Nivotester FTR325 monitors the Soliwave M microwave barrier s open collector output and uses a relay (change-over gate) to provide this output for many user applications. An LED displays the switching state of the relay. Problems such as a cable breakage are also displayed. The input on the Nivotester FTR325 is galvanically isolated from main power and output. It is connected to the microwave barrier via a three-wire cable (ring or star wiring), whereupon the Nivotester provides distribution (DC) voltage to the microwave barrier. Limit switch signal function The appropriate setting for the limit switch signal function (see page 8) ensures that the relay for signal output and fault is always activated (fail-safe mode) in idle state. In combination with the Soliwave M microwave barrier the following secure modes are possible: The relay drops out when the switch point is reached (microwave barrier interrupted), a fault occurs or the distribution voltage fails. The relay drops out when the switch point is underrun (microwave barrier uninterrupted), a fault occurs or the distribution voltage fails. Function monitoring system The Nivotester FTR325 is equipped with function monitoring system for improved fail-safe operation. A fault is indicated by an LED, the signal output and fault relay falls off. In combination with the microwave barrier Soliwave M FQR50/FDR50-A* (non hazardous area) and -B* (ATEX II 1/2 D) respectively the Nivotester FTR325-A* (non hazardous area) can recognise the following faults and use an LED to indicate them: Breakage in the distribution voltage cable to the microwave barrier Microwave barrier power input (emitter FQR50 and/or receiver FDR50) too high Short-circuit (emitter FQR50, receiver FDR50 or wiring) In combination with the microwave barrier Soliwave M FQR50/FDR50-C* (ATEX II 1/2 GD) the Nivotester FTR325-B* (ATEX II (1) GD) can recognise the following faults and use an LED to indicate them: Breakage in the distribution voltage cable to the emitter FQR50 Microwave barrier power input (emitter FQR50 and/or receiver FDR50) too high Short-circuit (emitter FQR50, receiver FDR50 or wiring) Manual function monitoring can be carried out by pushing the test button. 3

Measuring system The complete measuring system for level measurement detection consists of: a FQR50 emitter, a FDR50 receiver and a Nivotester FTR325 switch amplifier FQR50 FDR50 FTR325 Nivotester FTR325 with Silowave M microwave barrier Optical or acoustic signal transmitters, gates, relays, magnetic valves, etc. can be connected to the Nivotester. # The following equipment combinations are possible: Nivotester FTR325-A* (non hazardous area) with FQR50/FDR50-A* (non hazardous area) Nivotester FTR325-A* (non hazardous area) with FQR50/FDR50-B* (ATEX II 1/2 D) Nivotester FTR325-B* (ATEX II (1) GD) with FQR50/FDR50-C* (ATEX II 1/2 GD) The following equipment combinations are impossible: Nivotester FTR325-A* (non hazardous area) with FQR50/FDR50-C* (ATEX II 1/2 GD) Nivotester FTR325-B* (ATEX II (1) GD) with FQR50/FDR50-A* (non hazardous area) Nivotester FTR325-B* (ATEX II (1) GD) with FQR50/FDR50-B* (ATEX II 1/2 D) 4

Characteristics Measured value A limit signal is generated when the microwave barrier is either inter-rupted or uninterrupted, depending on the type of limit signal selected. Input signal FTR325 input: - Soliwave M microwave barrier - input galvanically isolated from power supply - intrinsically safe circuit at the version FTR325-B* (ATEX II (1) GD) Output signal Relay output: - galvanically isolated from power supply - a potential-free switching contact for the limit signal - a potential-free switching contact for fault notification Breaking capacity for relay contacts: U~ max. 253 VAC I~ max. 2 A (AC) P~ max. 500 VA (cos φ 0.7) U max. 40 VDC I max. 2 A (DC) P max. 80 W Switching frequency: max. 2 Hz Service life: min. 10 5 switching operations at max. contact load Function indicators: LEDs for - On (green) - Limit signal (yellow) - Fault (red) Power for microwave barrier: - supplied by the Nivotester FTR325 - intrinsically safe circuit at the version FTR325-B* (ATEX II (1) GD) Auxiliary energy Supply voltage AC voltage model - Voltage range: 85.. 253 VAC, 50/60 Hz - Power consumption: max. 1.75 W DC voltage model - Voltage range: 20.. 30 VAC / 20.. 60 VDC - Power: max. 1.75 W - Verpolungsschutz 5

Electrical connection Connecting cable FTR325-A* with FQR50/FDR50-A* (non hazardous area) and FQR50/FDR50-B* (ATEX II 1/2 D): Off-the-shelf installation cable, 3-conductor, shielded Line resistance maximum 25 Ω per wire Example cable length Copper cable, specific resistance ρ = 0.0172 Ωmm 2 /m, cross section 0.75mm 2 The maximum cable length is 1090 m. FTR325-B* with FQR50/FDR50-C* (explosive gas/dust atmospheres, intrinsically safe): Off-the-shelf installation cable, 3-conductor, non-shielded Resistance: 15 Ω/km R' 150 Ω/km Inductance: 0.4 mh/km L' 1 mh/km Capacitance: 45 nf/km C' 200 nf/km Length of spurs max. 1000 m (IIC) and 5000 m (IIB) respectively The supply voltage is attached to terminals 1&2. Internally there is a micro-fuse built into the supply voltage circuit so that only one fuse for short circuits in the feed line to the FTR325 must be upstream. ---- X2 Refer to the nameplate! ---- X1 CH1 N L1 U~ 85... 253 V (AC) 50/60 Hz } CH1 L- N L+ L1 U- 20... 60 V (DC) U~ 20... 30 V (AC) 50/60 Hz F ---- X1 ---- X2 max. 1.5 mm 2 (max. AWG 16) Connecting supply voltage The four plug terminals are a part of the device. Wiring When connected to the Nivotester FTR325 a Soliwave M microwave barrier can be wired via a choice of ring or star connection. The required backup power is provided by the FTR325. 6

Equipment combinations Ring wiring # The following equipment combinations are possible: Nivotester FTR325-A* (non hazardous area) with FQR50/FDR50-A* (non hazardous area) Nivotester FTR325-A* (non hazardous area) with FQR50/FDR50-B* (ATEX II 1/2 D) Nivotester FTR325-B* (ATEX II (1) GD) with FQR50/FDR50-C* (ATEX II 1/2 GD) All other combinatins are not allowed! Wiring example 1: Nivotester FTR325 with ring connection to Soliwave M microwave barrier Emitter FQR50 Receiver FDR50 Nivotester FTR325 Contact circuit (terminals 3, 4, 5) and alarm signal output (terminals 15, 16) Power supply (terminal 1, 2): A = U~ 85... 253 V(AC), 50 / 60 Hz E = U- 20... 60 V(DC) U~ 20... 30 V(AC), 50 / 60 Hz FTR325 with ring connection to Soliwave M Star wiring Wiring example 2: Nivotester FTR325 with star connection to Soliwave M microwave barrier Emitter FQR50 Receiver FDR50 Nivotester FTR325 Contact circuit (terminals 3, 4, 5) and alarm signal output (terminals 15, 16) Power supply (terminal 1, 2): A = U~ 85... 253 V(AC), 50 / 60 Hz E = U- 20... 60 V(DC) U~ 20... 30 V(AC), 50 / 60 Hz FTR325 with star connection to Soliwave M 7

Controls and instrumentation Control concept On site adjustments using switches and potentiometers behind the hinged face plate. Indicators Green LED: operational state Yellow LED: switching state Red LED: fault Control elements Limit switch signal function Test button Fault notification LED row: YE - yellow (switch state) RD - red (fault) GN - green (operation) Control elements for limit switch signal, fault and test Limit switch signal function: - Switches the limit switch relay on or off when the microwave barrier is either interrupted or uninterrupted, depending on the type of limit signal selected. - Optical indication of switching state via yellow LED Fault notification: - When activated switches on the fault relay when a fault occurs - Optical indication of a fault via red LED Fault notification: - When activated switches on the fault relay when a fault occurs - Optical indication of a fault via red LED You can find detailed information on the different settings options in the KA205F/97/a6 compact manual. 8

Switch delay (pick up delay) t(t) = 0.5..20 s T T S S t(s) = 0.5..20 s Switch delay (drop out delay) Control elements switch delay Switch delay (pick up delay): - When switch delay activated limit switch relay switches on pick up delay after time t(t) - Adjustable time: t(t) = 0.5.. 20 s Switch delay (drop out delay): - When switch delay activated limit switch relay switches off drop out delay after time t(s) - Adjustable time: t(s) = 0.5.. 20 s Note! The switching frequency (maximum 2 Hz) is given by the microwave barrier Soliwave M. You can find detailed information on the different setting options in the KA205F/97/a6 compact manual. 9

Operating conditions Installation location The Nivotester FTR325 is mounted upright on a DIN rail (TS 35 as per EN 50022). A protective case (IP 65, see accessories) is available for external installation. min. IP 55 45 mm 112 mm x2 x1 95 mm 108 mm x2 x1 DIN rail mounting DIN rail EN 50022-35x7.5 / EN 50022-35x15 100 mm = 3.94 in Ambient conditions When installed individually - 20 C... + 60 C When installed in-line without clearance spaces - 20 C... + 50 C When installed in protective case - 20 C... + 40 C Storage temperature - 20 C... + 85 C (preferably at + 20 C) Note! If possible mount devices so that they are not subjected to direct sunlight. This applies especially to use in warmer climates. Protection type (according to EN 60529) IP 20 10

Safety instructions Installation The Nivotester FTR325 may not be used in explosive areas. Non-explosive area Explosive area Zone 20 FTR325-A* Emitter FQR50-B* Receiver FDR50-B* Zone 21 FTR325-B* Emitter FQR50-C* Zone 0 and Zone 20 Receiver FDR50-C* Zone 1 and Zone 21 Classification of zone areas of the measuring system Safety notes for electrical equipment for potentially explosive atmospheres The following equipment combinations are allowed to operate in explosive area: - FTR325-A* with FQR50/FDR50-B* (see Safety Instructions XA223F/97/a3) - FTR325-B* with FQR50/FDR50-C* (see Safety Instructions XA219F/97/a3) Install the device according to the manufacturer's instructions and any other valid standards and regulations (e.g. EN/IEC 60079-14). Incorrect use of the device poses a danger. The device may be installed, hooked up and put into operation only by qualified and authorized persons with special attention paid to - the operating manual, - the relevant standards and - legal rules and regulations. The Nivotester can be serviced by the manufacturer only. 11

Mechanical construction Structure shape Housing: In-line case (Minipac shape) made of plastic Installation: on DIN rails according to EN 50022-35 x 7.5 or EN 50022-35 x 15 Protecting class according to EN 60529: IP 20 Materials Housing: - Polycarbonate - Color: Light grey, RAL 7035 Front panel: - Polyamide PA6 - Color: Blue, RAL 5012 Mounting slide (for attaching to the DIN rail): - Polyamide PA6 - Color: Black, RAL 9005 Clearances 40 mm FTR325 FTR325 FTR325 Clearances 45 mm 112 mm 95 mm 108 mm FTR325 In-line assembly Protective case Dimensions Dimensions 12

Ordering information Ordering information Nivotester FTR325 10 Certificate: A Variants for the ex-free atmosphere B ATEX II (1)G [Ex ia] IIC ATEX II (1)D [Ex iad] Y Special version, to be specified 20 Model: 1 DIN rail mounting, b = 45 mm 9 Special version, to be specified 30 Power supply: A 85-253 VAC, 50/60 Hz E 20-60 VDC / 20-30 VAC, 50/60 Hz Y Special version, to be specified 40 Output: 1 1x Filling level SPDT + 1x Alarm/filling level SPST 9 Special version, to be specified FTR325 - Order code Designation Nameplate Order code Serial number 8B0001KIR02 Power supply Certification Nameplate FTR325 13

Accessories Protective housing A protective housing for field installation of top-hat rail devices e. g. Nivotester FTR325 is available. In this housing there is space for several top-hat rail devices (to a maximum installation width of 145 mm). Technical data - Order code: 52010132 - Protection type (according to EN 60529): IP 66 - Lower housing section: fibre-glass reinforced polycarbonate, grey - Upper housing section: polycarbonate, transparent - Seal: PU seal - Top-hat rail (EN 50022): galvanized - Cable entries: 5 pieces M20 x 1.5 180 165 165 182 165 Protective housing for FTR325 14

Certificates and approvals CE symbol The Nivotester FTR325 fulfils the legal requirements of the EEC directives. The manufacturer confirms the successful examination of the equipment by using the CE mark. Ex approval External standards and directives ATEX II (1)G [Ex ia] IIC (Certification no. BVS 07 ATEX E 148 X) ATEX II (1)D [Ex iad] (Certification no. BVS 07 ATEX E 148 X) Directive 1999/05/EC annex 3.1 (a and b) and the directives 73/23/EEC and 89/336/EEC found in there Supplementary documentation Operating instructions (KA) Nivotester FTR325 KA205F/97/a6 Soliwave M FQR50/FDR50 KA206F/97/a6 Technical informations Soliwave M FQR50/FDR50 TI378F/97/de Protective Housing for Field Installation of Top-hat Rail Devices TI367F/00/de Safety instructions Soliwave M FQR50/FDR50-B* with the Nivotester FTR325-A* XA223F/97/a3 Soliwave M FQR50/FDR50-C* with the Nivotester FTR325-B* XA219F/97/a3 15

Subject to modification International Head Quarter GmbH+Co. KG Instruments International Colmarer Str. 6 79576 Weil am Rhein Deutschland Tel. +49 76 21 9 75 02 Fax +49 76 21 9 75 34 5 www.endress.com info@ii.endress.com 16 TI377F/97/en/11.07 InDesign 2.0.2