Bearing Currents and Shaft Voltage Reduction in Dual-Inverter-Fed Open-End Winding Induction Motor With CMV PWM Methods Employing PID

Similar documents
Bearing Currents and Shaft Voltage Reduction in Dual-Inverter-Fed Open-End Winding Induction Motor With CMV PWM Methods Employing PID

MODELLING AND SIMULATION OF DIODE CLAMP MULTILEVEL INVERTER FED THREE PHASE INDUCTION MOTOR FOR CMV ANALYSIS USING FILTER

Mr. DILIP J. Final Year Mtech Student Dept of EEE The Oxford College of Engineering, Bangalore

Common Mode Voltage Reduction in a Three Level Neutral Point Clamped Inverter Using Modified SVPWM

IT HAS LONG been recognized that bearing damage can be

A Series-Connected Multilevel Inverter Topology for Squirrel-Cage Induction Motor Drive

Simulation and Experimental measurement of Shaft Voltage, Bearing current in Induction Motor drive using Micro-controller

REDUCTION OF COMMON-MODE VOLTAGE IN OPEN END WINDING INDUCTION MOTOR DRIVE USING CARRIER PHASE-SHIFT STRATEGY

Bearing Currents and Shaft Voltages of an Induction Motor Under Hard and Soft Switching Inverter Excitation

Product Application Note

Ripple Reduction Using Seven-Level Shunt Active Power Filter for High-Power Drives

Australian Journal of Basic and Applied Sciences. Simulation and Analysis of Closed loop Control of Multilevel Inverter fed AC Drives

REDUCTION OF ZERO SEQUENCE VOLTAGE USING MULTILEVEL INVERTER FED OPEN-END WINDING INDUCTION MOTOR DRIVE

Low Order Harmonic Reduction of Three Phase Multilevel Inverter

Modeling and Analysis of Common-Mode Voltages Generated in Medium Voltage PWM-CSI Drives

REDUCTION OF COMMON MODE VOLTAGE IN THREE PHASE GRID CONNECTED CONVERTERS THROUGH NOVEL PWM TECHNIQUES

Reduction of Harmonics and Torque Ripples of BLDC Motor by Cascaded H-Bridge Multi Level Inverter Using Current and Speed Control Techniques

RCL filter to suppress motor terminal overvoltage in PWM inverter fed Permanent Magnet synchronous motor with long cable leads

Suppression of Common Mode Voltage and Differential Mode Harmonics in Three Phase Inverter Using Hybrid Filter

A New Control Method for Balancing of DC-Link Voltage and Elimination of Common Mode Voltage in Multi-level Inverters

Application Note. Motor Bearing Current Phenomenon. Rev: Doc#: AN.AFD.17 Yaskawa Electric America, Inc August 7, /9

Active damping of output LC filter resonance for vector controlled VSI- fed AC motor drive

CAPACITOR VOLTAGE BALANCING IN SINGLE PHASE SEVEN-LEVEL PWM INVERTER

Decoupled Space Vector PWM for Dual inverter fed Open End winding Induction motor drive

A NEW C-DUMP CONVERTER WITH POWER FACTOR CORRECTION FEATURE FOR BLDC DRIVE

Phase Shift Modulation of a Single Dc Source Cascaded H-Bridge Multilevel Inverter for Capacitor Voltage Regulation with Equal Power Distribution

INTERNATIONAL JOURNAL OF PROFESSIONAL ENGINEERING STUDIES Volume VIII /Issue 2 / FEB 2017

Srinivas Dasam *, Dr. B.V.Sanker Ram **,A Lakshmisudha***

Determination of EMI of PWM fed Three Phase Induction Motor. Ankur Srivastava

B. Muralidhara Member, IACSIT, A. Ramachandran, R. Srinivasan, and M. Channa Reddy

Simulation with Experimental Measurement of Voltage Total Harmonic Distortion and Harmonic Frequency in Three-Phase Induction Motor fed from Inverter

COMPARISON STUDY OF THREE PHASE CASCADED H-BRIDGE MULTI LEVEL INVERTER BY USING DTC INDUCTION MOTOR DRIVES

Electromagnetic Compatibility and Better Harmonic Performance with Seven Level CHB Converter Based PV-Battery Hybrid System

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

International Journal of Emerging Technology in Computer Science & Electronics (IJETCSE) ISSN: Volume 11 Issue 1 NOVEMBER 2014.

Multilevel Current Source Inverter Based on Inductor Cell Topology

Reducing the Fault Current and Overvoltage in a Distribution System with an Active Type SFCL Employed PV System

A Novel Five-level Inverter topology Applied to Four Pole Induction Motor Drive with Single DC Link

Minimization Of Total Harmonic Distortion Using Pulse Width Modulation Technique

Decoupled Centric and Non-Centric PWM Techniques for Open-End Winding Induction Motor Drive

Space vector pulse width modulation for 3-phase matrix converter fed induction drive

Voltage Balancing in SVM Controlled Diode Clamped Multilevel Inverter for Adjustable drives

COMMON mode current due to modulation in power

A Novel Cascaded Multilevel Inverter Using A Single DC Source

CHAPTER-6 MEASUREMENT OF SHAFT VOLTAGE AND BEARING CURRENT IN 2, 3 AND 5-LEVEL INVERTER FED INDUCTION MOTOR DRIVE

THE problem of common-mode voltage generation in inverter-fed

IN recent years, the development of high power isolated bidirectional

Modelling and Simulation of New PV-Battery Based Hybrid Energy System for Z source Inverter using SVPWM fed Industrial Applications

Enhanced Performance of Multilevel Inverter Fed Induction Motor Drive

Improvement of Power Quality by Using 28-Pulse AC-DC Converter

IEEE TRANSACTIONS ON INDUSTRIAL ELECTRONICS, VOL. 62, NO. 7, JULY

Comparison between Conventional and Modified Cascaded H-Bridge Multilevel Inverter-Fed Drive

Measurement and reduction of EMI radiated by a PWM inverter-fed AC motor drive system

Hybrid 5-level inverter fed induction motor drive

ON-LINE NONLINEARITY COMPENSATION TECHNIQUE FOR PWM INVERTER DRIVES

High Efficiency Single Phase Transformer less PV Multilevel Inverter

A Novel Three-Phase to Nine-Phase Transformation using a Special Transformer Connection

International Journal of Advance Research in Engineering, Science & Technology

International Journal Of Engineering And Computer Science ISSN: Volume 2 Issue 12 December, 2013 Page No Abstract

Reduction of Power Electronic Devices with a New Basic Unit for a Cascaded Multilevel Inverter fed Induction Motor

Simulation and Comparision of Back To Back System using Bidirectional Isolated DC-DC Converter with Active Energy Storage

IJCSIET--International Journal of Computer Science information and Engg., Technologies ISSN

Hybrid PWM switching scheme for a three level neutral point clamped inverter

OUTLINE. Introduction. Introduction. Conducted Electromagnetic Interference in Smart Grids. Introduction. Introduction

HIGH EFFICIENCY TRANSFORMER LESS INVERTER FOR SINGLE-PHASE PHOTOVOLTAIC SYSTEMS USING SWITCHING CONVERTER

1-PHASE TRANSFORMATION OF A TRANSFORMER FROM THREE PHASE TO FIVE PHASE USING A NEW CONNECTION

Sensorless control of BLDC motor based on Hysteresis comparator with PI control for speed regulation

Switching Angles and DC Link Voltages Optimization for. Multilevel Cascade Inverters

Analysis And Comparison Of Flying Capacitor And Modular Multilevel Converters Using SPWM

Performance Evaluation of Isolated Bi-directional DC/DC Converters with Buck, Boost operations

Cascaded Two Level Electrical Converter-Based Multilevel STATCOM for High Power Utilization

SPACE VECTOR BASED DECOUPLED PWM TECHNIQUES FOR OPEN END WINDING INDUCTION MOTOR DRIVE

Improvement of Power Quality Using Hybrid Active Power Filter in Three- Phase Three- Wire System Applied to Induction Drive

ISSN Vol.07,Issue.11, August-2015, Pages:

A Fifteen Level Cascade H-Bridge Multilevel Inverter Fed Induction Motor Drive with Open End Stator Winding

A Novel H Bridge based Active inductor as DC link Reactor for ASD Systems

Series Parallel Switched Multilevel DC Link Inverter Fed Induction Motor

Soft Switching with Cascaded Transformers to Drive the PMDC Motor

Technical White Paper

Three Phase Parallel Multilevel Inverter Fed Induction Motor Using POD Modulation Scheme

HIGH POWER FACTOR INDUCTION HEATING SYSTEM WITH INTERLEAVED VARIABLE DUTY CYCLE

THREE PHASE UNINTERRUPTIBLE POWER SUPPLY BASED ON TRANS Z SOURCE INVERTER

Hybrid Full-Bridge Half-Bridge Converter with Stability Network and Dual Outputs in Series

ADVANCED PWM SCHEMES FOR 3-PHASE CASCADED H-BRIDGE 5- LEVEL INVERTERS

Implementation of Single Stage Three Level Power Factor Correction AC-DC Converter with Phase Shift Modulation

INTERNATIONAL JOURNAL OF PURE AND APPLIED RESEARCH IN ENGINEERING AND TECHNOLOGY

Photo Voltaic Systems Power Optimization under Cascaded Inverter Environment

Performance Enhancement of a Novel Interleaved Boost Converter by using a Soft-Switching Technique

POWER QUALITY IMPROVEMENT BY USING ACTIVE POWER FILTERS

SPECIFIC HARMONIC ELIMINATION SCHEME FOR NINELEVEL CASCADED H- BRIDGE INVERTER FED THREE PHASE INDUCTION MOTOR DRIVE

Literature Survey: Multilevel Voltage Source Inverter With Optimized Convention Of Bidirectional Switches

Research on Parallel Interleaved Inverters with Discontinuous Space-Vector Modulation *

SIMULATION, DESIGN AND CONTROL OF A MODIFIED H-BRIDGE SINGLE PHASE SEVEN LEVEL INVERTER 1 Atulkumar Verma, 2 Prof. Mrs.

SPACE VECTOR PULSE WIDTH MODULATION SCHEME FOR INTERFACING POWER TO THE GRID THROUGH RENEWABLE ENERGY SOURCES

SEVEN LEVEL HYBRID ACTIVE NEUTRAL POINT CLAMPED FLYING CAPACITOR INVERTER

Design of EMI Filters for DC-DC converter

Improving Passive Filter Compensation Performance With Active Techniques

IJREAT International Journal of Research in Engineering & Advanced Technology, Volume 1, Issue 1, March, 2013 ISSN:

CHAPTER 1 INTRODUCTION

Selected Problems of Induction Motor Drives with Voltage Inverter and Inverter Output Filters

Transcription:

Bearing Currents and Shaft Voltage Reduction in Dual-Inverter-Fed Open-End Winding Induction Motor With CMV PWM Methods Employing PID T.Rakesh 1, K.Suresh 2 1 PG Scholar (PS), Nalanda Institute of Engineering and Technology, Sattenapalli, Guntur Dt, A.P 2 Associate Professor (EEE), Nalanda Institute of Engineering and Technology, Sattenapalli, Guntur Dt, A.P Abstract- Exploiting the rich switching redundancies of the dual inverter, new hybrid pulse width-modulation (PWM) switching methods are proposed in this paper using the degree of freedom of operating the individual inverters independently, in addition to exercising the degree of freedom of controlling the switching action of the individual legs independently. Two voltage entities, namely, common-mode voltage (CMV) and differential mode voltage are identified in the dual inverter, and all hybrid PWMs are envisaged aimed at reducing and also eliminating the CMV in it. The effects of such attempts on motor shaft voltage and also the motor bearing currents are presented in detail. Furthermore, bearing current profiles of an open-end winding induction motor are also presented with both conventional and hybrid PWMs proposed in this paper. Electric discharge machining discharge currents are completely eliminated with the use of all hybrid PWM methods proposed in this paper. In addition, implications of completely eliminating the CMV are also presented in this paper. All hybrid PWMs proposed in this paper are first simulated using MATLAB and implemented the system with PID to enhance the performance. I.INTRODUCTION Inverter-driven ac motors have become common in variable speed applications due to increased energy conservation. The use of high-frequency PWM methods and also multilevel inverters make the output voltage of the inverters more sinusoidal but also generate high common-mode voltage (CMV). From the studies on PWM-inverter-fed drives in the last few decades, it is found that high-frequency CMV of the inverters causes voltage drop across the bearings and this may cause bearing currents leading to premature bearing failures. Owing to increased cost of maintenance and downtime, attention on protecting the motor bearings has increased. Among the known solutions such as the use of brushes, insulated bearings, and electrostatic shielding, the use of appropriate filters is reported in. Also, new PWM methods are proposed for the two-level inverters that only reduce the CMV generated by them since complete elimination is not possible. To investigate the impact of CMV generated by PWM inverters on bearing currents, a simplified measurement setup is proposed in that enables the measurement of motor shaft voltage and motor bearing current in an induction motor driven from a two-level inverter. Multilevel inverters can also offer excellent solutions in reducing the CMV and the related problems. Reducing the motor shaft voltage and bearing currents using multilevel inverters is reported in and Of many multilevel inverter topologies, the dual-inverter topology employing openend winding induction motor drive has slowly gaining popularity ever since it was introduced as it inherits many advantages compared to its counterparts. In, a dual inverter fed from two isolated dc sources and also a single dc source is presented. However, arresting circulating zero sequence currents in the motor phase windings is addressed using zero sequence chokes in single-dc-source-driven dual inverter. Later, many PWM methods are reported for the dual inverter for achieving improved performance. The available literature on dual-inverter-fed motor drives suggests that the voltage that is responsible for circulating zero sequence current in it is termed as zero sequence voltages (ZSVs) by few researchers and CMV by some, and the focus has been only to reduce and/or eliminate such voltage using new PWM methods that arrests the circulating current flow, thus leading to deriving the advantage of dual inverter that can be fed from a single dc power source. In, it is demonstrated that ZSV IJEDR1602334 International Journal of Engineering Development and Research (www.ijedr.org) 1899

in the dual inverter can be forced to zero in the average sense in every sampling time interval by suitably placing the effectivetime periods of the individual inverters. Recently, it has been shown that the effective-time periods of the individual inverters can be independently controlled to control the ripple content in the load current. From the knowledge of motor shaft voltage which is found to be replica of the CMV output of the inverter, the equivalent voltage in the dual inverter that is responsible for motor shaft voltage is clearly identified, and analytical expression for the same is first presented in. In, four new hybrid PWMs are proposed that successfully reduce the motor shaft voltage by following the reduced CMV principles reported for the two level inverter in. Exploiting the rich switching redundancy of the dual two level inverter, new hybrid PWM methods are proposed in this paper for the dual inverter, which are aimed at reducing and also eliminating the CMV output. Bearing current profiles composed of capacitive bearing currents (dv/dt) and the electric discharge machining (EDM) discharge currents are presented for the open-end winding induction motor drive fed from dual inverter with conventional and also hybrid PWM methods proposed in this paper. The effects of reducing and eliminating CMV in the dual inverter on motor shaft voltage and bearing currents are also presented in this paper. The proposed hybrid PWMs succeed in reducing the motor shaft voltage to such an extent that they manage to completely keep the EDM discharge currents away in the open-end winding induction motor that are known to be dominant in low-power-rating motors [2]. The envisaged propositions are first simulated using MATLAB and are validated experimentally. The power circuit configuration of a dual two-level inverter feeding open-end stator windings of a 3-φ induction motor load is shown in Fig. 1. This topology can synthesize a three level voltage space vector similar to any other equivalent three level inverter topology. Each inverter in Fig. 1 is capable of attaining eight switching states. The dual two-level inverter is thus capable of attaining 82, i.e., 64, switching states. From Fig. 1, the three-phase voltages of the open-end winding induction motor can be given as II. DUAL TWO-LEVEL INVERTER FOR THREE- LEVEL INVERSION The voltage space vector thus generated can be written as The space vectors generated for all 64 switching combinations are obtained using (2) and are shown in Fig. 2(a) (spread around 19 space vector locations). From Fig. 2(a), it can be appreciated that the dual inverter offers high degree of freedom in choosing the switching combinations for realizing a given space vector. IJEDR1602334 International Journal of Engineering Development and Research (www.ijedr.org) 1900

Fig. 2. (a) Space vectors generated by dual inverter. (b) Principle of decoupled PWMs for the dual inverter. However, the high-frequency PWM inverters excite the machine parasitic capacitances, resulting in the CMV appearing across the motor phase windings. Based on the paths provided by the parasitic capacitances, common- and differential-mode current components can flow in the PWM inverter drive. Common- and differential-mode current paths in dual inverter- fed open-end winding induction motor drive are now shown in Fig. 3. Common-mode current flows through the motor frame and returns to the inverters and/or input ac mains (not shown in Fig. 3 in the interest of brevity), whereas differential-mode current flows between inverter legs and the motor phase windings. In Fig. 3, Lc is the leakage inductance of motor phase windings, Zc is the parasitic impedance between stator phase windings to motor frame (grounded), and Zo and Z_ o are the parasitic impedances between inverter ground (heat sink) and O and O_ of inverter-1 and inverter-2, respectively. Since the open-end stator windings are energized by two voltage sources, as shown in Fig. 3, zero sequence current can circulate in the phase winding that is decided by the difference between the two source voltages. This can be defined in terms of CMV of the individual inverters (vcmv1 and vcmv2) as It can be seen that the common-mode leakage ground current (ig) flows from the inverters to the motor frame (grounded) through the stray impedances formed by Zc and Zo, and Zc and Z_ o. Hence, CMV in the dual inverter can be written in terms of the CMV of the individual as Fig. 3. Common- and differential-mode currents in dual-inverterfed open-end winding induction motor. Isolated dc sources are used for the dual inverter to arrest the flow of circulating current in the motor phase windings. The resulting CMV for all 64 switching combinations can be obtained by using (5), as presented in. The distinction between the profiles of CMV and differential-mode voltage (DMV) given in (4) and (5) is clearly shown in Sections III and IV. In the case of dual inverter, the CMV generated by it gets reflected as motor shaft voltage in open-end winding induction motor load. On the other hand, the other entity, the DMV, is responsible for the circulating current in the motor phase windings (if there exists a path). IJEDR1602334 International Journal of Engineering Development and Research (www.ijedr.org) 1901

Several PWMs have been reported in the literature on minimizing and eliminating the latter components, leaving scope for investigations on the former part. As explained in the previous section that there exists a high degree of freedom in the selection of switching combinations in the dual inverter, various hybrid PWMs are proposed in this paper that not only reduce the magnitude of CMV in the dual inverter but also reduce its frequency of occurrence. Synthesized by the individual twolevel inverters and the principle is depicted in Fig. 2(b). In addition to exercising the options of independently controlling the individual inverters, additional degree of freedom of independent switching of inverter legs is explored in the present paper. Fig.5 CMVs in the dual inverter when controlled with PI Fig.6 bearing current and motor shaft voltage profile with PI Fig.4 matlab circuit for proposed system with PI Fig.7 matlab circuit for proposed system with PID IJEDR1602334 International Journal of Engineering Development and Research (www.ijedr.org) 1902

Fig.8 CMVs in the dual inverter when controlled with PID Fig.9 bearing current and motor shaft voltage profile with PID CONCLUSION Three-level inversion has been achieved with hybrid PWM switching methods proposed in this paper by exploring the degree of freedom of adopting independent PWM methods for the individual inverters in addition to operating them independently. Motor shaft voltage in the dual-inverter scheme is found to be a replica of CMV of the dual inverter while DMV is identified to be entirely different from CMV. Analytical expressions are presented for both, supported by theoretical and experimental results. New hybrid PWM switching methods have been envisaged in this paper, aimed at reducing the CMV output from the dual inverter with the intention of reducing motor shaft voltage, and have been found successful. In addition, investigations on completely eliminating the CMV have also been presented in this paper using selected hybrid PWM method, and inherent difficulties have clearly been presented with detailed analysis. Furthermore, bearing current profiles have also been presented with both conventional PWMs and hybrid PWMs proposed in this paper. EDM discharge currents that are reported to be the main sources of bearing damages in small-mediumpower motors are completely eliminated with the use of the hybrid PWM methods proposed in this paper, demonstrating their effectiveness. REFERENCES [1] J. M. Erdman, R. J. Kerkman, D. W. Schlelgel, and G. L. Skibinski, Effect of PWM inverters on AC motor bearing currents and shaft voltages, IEEE Trans. Ind. Appl., vol. 32, no. 2, pp. 250 259, Mar./Apr. 1996. [2] A. Muetze, Bearing currents in inverter fed AC motors, Ph.D. dissertation, Technische Universitaet Darmstadt, Darmstadt, Germany, 2004. [3] D. Dahl, D. Sosnowski, D. Schlegel, R. J. Kerkman, and M. Pennings, Gear up your bearings, IEEE Ind. Appl. Mag., vol. 14, no. 4, pp. 45 53, Jul./Aug. 2008. [4] A. Willwerth and M. Roman, Electrical bearing damage A lurking problem in inverter-driven traction motors, in Proc. IEEE ITEC, Jun. 16 19, 2013, pp. 1 4. [5] A. Datta, M. Dubey, and S. Jain, Effect of static power supply in alternator used for short circuit testing observation of shaft voltage, IEEE Trans. Power Electron., vol. 29, no. 11, pp. 6074 6080, Nov. 2014. [6] A. Muetze, J. Tamminen, and J. Ahola, Influence of motor operating parameters on discharge bearing current activity, IEEE Trans. Ind. Appl., vol. 47, no. 4, pp. 1767 1777, Jul./Aug. 2011. [7] N. Zhu, J. Kang, D. Xu, B. Wu, and Y. Xiao, An integrated AC choke design for common-mode current suppression in neutral-connected power converter systems, IEEE Trans. Power Electron., vol. 27, no. 3, pp. 1228 1236, Mar. 2012. [8] A. Muetze and C. R. Sullivan, Simplified design of common-mode chokes for reduction of motor ground currents in IJEDR1602334 International Journal of Engineering Development and Research (www.ijedr.org) 1903

inverter drives, IEEE Trans. Ind. Electron., vol. 47, no. 6, pp. 2570 2577, Nov./Dec. 2011. [9] H. Akagi and T. Shimizu, Attenuation of conducted EMI emissions from an inverter-driven motor, IEEE Trans. Power Electron., vol. 23, no. 1, pp. 282, 290, Jan. 2008. [10] N. O. Cetin and A. M. Hava, Compatibility issues between the filter and PWM unit in three-phase AC motor drives utilizing the pure sine filter configuration, IEEE Trans. Ind. Electron., vol. 47, no. 6, pp. 2559 2569, Nov./Dec. 2011. First Author: T.Rakesh is pursuing his M.Tech from Nalanda Institute of engineering, Sattenapalli, Guntur dt. Affiliated to JNTUK, Kakinada, A.P, India. His Research Interests is Power Systems, Power Electronics. Second Author: K. S u r e s h is working as Associate Professor in Department Of EEE at Nalanda Institute of engineering, Sattenapalli, Guntur dt. Affiliated to JNTUK, Kakinada, A.P, India. His Research Interests are Power Systems, Power Electronics, and drives & FACTS devices. IJEDR1602334 International Journal of Engineering Development and Research (www.ijedr.org) 1904