17th World Conference on Nondestructive Testing, Oct 2008, Shanghai, China

Similar documents
SINCE2011 Singapore International NDT Conference & Exhibition, 3-4 November 2011

IMAGE ENHANCEMENT FOR RADIOGRAPHIC NON-DESTRUCTIVE INSPECTION OF THE AIRCRAFT

PERFORMANCE CHARACTERIZATION OF AMORPHOUS SILICON DIGITAL DETECTOR ARRAYS FOR GAMMA RADIOGRAPHY

APPLICATION OF THE DIGITAL RADIOGRAPHY IN WELD INSPECTION OF GAS AND OIL PIPELINES

Equivalent Penetrameter Sensitivity (EPS) for Performance Evaluation of Computed Radiography Systems Muzibur Khan * and Mike Brothers

Film Replacement in Radiographic Weld Inspection The New ISO Standard

Essential Parameters and Conditions for Optimum Image Quality in Digital Radiology

Moving from film to digital: A study of digital x-ray benefits, challenges and best practices

Amorphous Selenium Direct Radiography for Industrial Imaging

Digital Radiographic Inspection replacing traditional RT and 3D RT Development

Pre Conference Workshop on Advanced Digital imaging

Minimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations

Preliminary Modulation Transfer Function Study on Amorphous Silicon Flat Panel System for Industrial Digital Radiography

ON THE WAY TO DIGITAL RADIOGRAPHY

Digital Radiology with Photon Counting Detectors

A COMPARATIVE STUDY ON THE PERFORMANCE OF DIGITAL DETECTOR SYSTEMS FOR HIGH ENERGY APPLICATIONS

Determination of Optimum X-Ray Tube Output Parameters kv and ma for Digital Radiography Testing of Welded Tubes

Advanced Digital Radiography for Field NDT

Computed Radiography

NON-DESTRUCTIVE EVALUATION UTILIZING IMAGING PLATES FOR FIELD RADIOGRAPHY APPLICATIONS

The HOIS recommended practice for in-service computed radiography of pipes. Dr Stephen F Burch, WCNDT 2012, Durban, SA. April 2012

PRACTICAL CONSIDERATIONS AND EFFECTS OF METALLIC SCREEN FLUORESCENCE AND BACKSCATTER CONTROL IN GAMMA COMPUTED RADIOGRAPHY

Pixel Classification Algorithms for Noise Removal and Signal Preservation in Low-Pass Filtering for Contrast Enhancement

Real Time Linear Array Imaging. Brian Caccamise

Digital Radiography for the Inspection of Small Defects

Experiences of users in Digital Radiography

REAL-TIME X-RAY IMAGE PROCESSING; TECHNIQUES FOR SENSITIVITY

Essential Parameters for the Visibility of IQIs and Small Indications in Digital Radiography

IQI-Sensitivity and Applications of Flat Panel Detectors and X-Ray Image Intensifiers A Comparison

Strategies for Film Replacement in Radiography - a comparative study -

Fig.2: Scanner VistaScan for image plates

SECTION I - CHAPTER 2 DIGITAL IMAGING PROCESSING CONCEPTS

Digital Radiography : Flat Panel

FOCUS. Quick Industrial X-ray Testing Without Intermediate Data Carriers of Information. by V.A. Troitskiy

A True Innovation in Non-Destructive Testing System FUJIFILM COMPUTED RADIOGRAPHY. Series 4 CR

A Modified Detectability Criterion for Conventional Radiography Simulation

Performance evaluation of a photon counting detector for high energy NDT applications

Digital Radiography Systems Techniques and Performance Evaluation for Space Applications

Welding Inspection Non-Destructive Testing Course Reference WIS 5

Center for Nondestructive Evaluation 304 Wilhelm Hall Iowa State University Ames, Iowa 50010

Advancements In Digital Radiography: CR, DR, and DICONDE

Introduction To NDT. BY: Omid HEIDARY

» There are many possible techniques for making good radiographs. » Following a defined procedure will simplify technique

NON-DESTRUCTIVE EVALUATION SERIES

Digital Radiography and its Advantages in Field NDT Inspections Today

NEW POSSIBILITIES OF RADIATION CONTROL OF QUALITY OF WELDED JOINTS

10/3/2012. Study Harder

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film

Recommended Training Curriculum For Digital Radiography Personnel (Level II)

Photon Counting and Energy Discriminating X-Ray Detectors - Benefits and Applications

Australian Journal of Basic and Applied Sciences

Flash-Radiography Instead of Traditional Radiography with Intermediate Carriers of Information

I. PERFORMANCE OF X-RAY PRODUCTION COMPONENTS FLUOROSCOPIC ACCEPTANCE TESTING: TEST PROCEDURES & PERFORMANCE CRITERIA

DIGITAL RADIOGRAPHY. Digital radiography is a film-less technology used to record radiographic images.

Spokane Industries Computed Radiography Implementation Experience. David Jolin Technical Sales

Examination of Pipe Welds by Image Plate Based Computed Radiography System

5th Pan American Conference for NDT 2-6 October 2011, Cancun, Mexico

Introduction. Chapter 16 Diagnostic Radiology. Primary radiological image. Primary radiological image

A New Lamb-Wave Based NDT System for Detection and Identification of Defects in Composites

Migrating from traditional to Digital Radiography in Aerospace

10/26/2015. Study Harder

Time Saving in the X-Ray Production Control by using ASD

A Global-Local Contrast based Image Enhancement Technique based on Local Standard Deviation

ScienceDirect. Evaluation of Pipe Wall Thickness Based on Contrast Measurement using Computed Radiography (CR)

Digital radiography: Practical advantages of Digital Radiography. Practical Advantages in image quality

DOSE REDUCTION BY USE OF DIGITAL X-RAY DETECTORS. Bernhard REDMER

Hardware for High Energy Applications 30 October 2009

Part 3: Image quality classes

MAV-ID card processing using camera images

Research Article Digital Radiography Using Digital Detector Arrays Fulfills Critical Applications for Offshore Pipelines

NDT-PRO Services expands service offering

Digital Detector Array Image Quality for Various GOS Scintillators

Engineering Policy & Procedure

Overview. Corrosion detection improvement of oil and gas pipelines with industrial radiography method by using image processing.

Effective Presentation of Medical Images

The HOIS recommended practice for in-service computed radiography of pipes

Tomographic 3D-Radiometry for the Visualisation and Measurement of the Defects of Girth Seams

NON DESTRUCTIVE TESTING 2 MARK QUESTION & ANSWERS UNIT I

Conversion to Digital Radiography from Film Radiography

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing of fusionwelded

Australian Standard RADIOGRAPHY OF WELDED BUTT JOINTS IN METAL. Part 2 IMAGE QUALITY INDICATORS (IQI) AND RECOMMENDATIONS FOR THEIR USE

Minimum Requirements for Digital Radiography Equipment and Measurement Procedures by Different Industries and Standard Organizations

Dual and Multi-energy Radiography for CFRP Composites Inspection

Ray Detection Digital Image Quality and Influential Factors

AUTOMATED AND QUANTITATIVE METHOD FOR QUALITY ASSURANCE OF DIGITAL RADIOGRAPHY IMAGING SYSTEMS

Survey on Contrast Enhancement Techniques

A NOVEL HIGH SPEED, HIGH RESOLUTION, ULTRASOUND IMAGING SYSTEM

HIGH SPEED, HIGH RESOLUTION AND LOW COST DIGITAL RADIOGRAPHY

Digital Industrial Radiography

Advancements in Pipeline Girth Weld Inspection

UNDERSTANDING THE CURRENT CAPABILITIES AND LIMITATIONS OF DIGITAL INDUSTRIAL RADIOGRAPHY

Performing Contrast Limited Adaptive Histogram Equalization Technique on Combined Color Models for Underwater Image Enhancement

Digital Radiography, Flexible Risers

NDE Technology of Pressure Equipment in Line with International Standards

Histogram Equalization: A Strong Technique for Image Enhancement

Fusion of MRI and CT Brain Images by Enhancement of Adaptive Histogram Equalization

Local Contrast Enhancement using Local Standard Deviation

Chromatic X-Ray imaging with a fine pitch CdTe sensor coupled to a large area photon counting pixel ASIC

INNOVATION BY DESIGN. Toshiba A History of Leadership REMOTE CONTROL R/F SYSTEM

Methods of processing and image compression in an X-ray micro tomographic scanner. Syryamkin V.I. Osipov A.V., Kutsov M.S.

Transcription:

17th World Conference on Nondestructive Testing, 25-28 Oct 2008, Shanghai, China Real-time Radiographic Non-destructive Inspection for Aircraft Maintenance Xin Wang 1, B. Stephen Wong 1, Chen Guan Tui 2 Kai Peng Khoo 2, Frederic Foo 3 1 Nanyang Technological University, Singapore 2 Republic of Singapore Air Force, Singapore 3 Singapore Technologies Aerospace, Singapore Abstract Traditional radiography is a non-destructive inspection (NDI) process widely used for the detection of cracks and damage in aircraft structures. However, there are some limitations of traditional radiography. Existing film process requires chemical processing of the film and the quality of the images varies from shot to shot. The NDI crew spends as much time going back and forth between the office, equipment storage location, and the job site as they do taking the shots, developing the film, and inspecting the shots. Operations and equipment are not standardized across aircraft systems. Complicates assigning work to X-Ray technicians. The film development process requires a significant amount of climate controlled storage space for the new and used film. Real-time radiography (RTR) allows all the benefits of producing significant increases in magnification and image clarity, as well as efficient management of digital images. Image enhancement allows more accurate interpretation of digital radiography indications. In this paper, In order to identify suitable sensors and x-ray tube to meet the high sensitivity required to inspect aircraft, different x-ray systems were evaluated. Furthermore image enhancement methods are investigated for NDI inspection of the aircraft. 1 Introduction Non-destructive inspection (NDI) is widely used in many fields, particularly for the detection of cracks and damage in aircraft structures. One of the most important techniques used in NDI is radiography that is based on the transmission of X-rays or Gamma rays through an object to produce an image on radiographic film. Traditional radiography is a non-destructive inspection (NDI) process widely used for the detection of cracks and damage in aircraft structures. However, there are some limitations of traditional radiography. Existing film process requires chemical processing of the film and the quality of the images varies from shot to shot. The NDI crew spends as much time going back and forth between the office, equipment storage location, and the job site as they do taking the shots, developing the film, and inspecting the shots. Operations and equipment are not standardized across aircraft systems. Complicates assigning work to X- Ray technicians. The film development process requires a significant amount of climate controlled storage space for the new and used film. Digital Radiography has emerged as a leading technology for recording an x-ray image. It offers many advantages over conventional film-based radiography [1]. The most prominent among these are the increase in productivity, ease of archiving and retrieving images, use of powerful image processing tools to qualitatively improve and quantitatively study images, and the high sensitivity, implying a lower x-ray dose to inspect the object. Digital Radiography enhances productivity as it records a ready to process image in a very short time (order of few seconds)

and eliminates the need for any chemical processing required as in the case of using a film. Many digital detectors can be used in a real-time format, where a continuous series of images (30 frames per second) can be obtained. This enables online inspection and powerful algorithms can be developed to perform automated defect recognition (ADR), which leads to reduction of inspection costs. However, digital detectors were firstly developed for medical applications. Its weakest point is the low spatial resolution of most of the new digital detector systems in comparison to NDT film.ewert etc [2] analyzed the possibility of replacement of film radiography by digital techniques. The interrelationship between exposure time, photon flow and image quality was discussed. Finally they gave the conclusion that the digital detectors are suitable for film replacement. Bavendier etc [3] compared the film system and digital detector system with welds and turbine blade and verified that the advantages of digital radiographic system for aerospace application. 2 Evaluation of Digital X-ray Systems for Aircraft NDI Applications In this paper, in order to identify suitable digital x-ray system to meet the high sensitivity required to inspect aircraft, different sensors and x-ray tube were evaluated. The specimens used to evaluate the sensitivities of the x-ray systems is 6mm thick aluminium specimen with a 2T hole penetrameter and a wire IQI penetrameter as this specimen is the thinnest of all the specimen and it is Aluminum which is of lower density than steel. Thickness of 6mm was chosen, as it is the thinnest aircraft wing section required to be radiographed during phase servicing. 2.1 Comparison between amorphous silicon flat panel detector with X-ray image intensifier (II) Figure 1 shows the images of the wire type IQI on the 6mm Al specimen obtained at a magnification of 4 and using: (a) image intensifier and (b) amorphous silicon flat panel. In both the images (a) and (b), the No. 15 IQI wire is detectable. Figure 2 shows the Plots, (a) and (b), of the lines crossing the IQI wires in the images (a) and (b) in Figure 1. It can be seen from the plots that the contrast produced by the IQI wires in the image (b) is much larger than that in the image (a). The signal to noise ratio in the image (b) is also higher than that in the image (a). In the II image, the brightness in the center is much higher than that in the area near the image edge. On the contrary, the brightness of the background is more uniform in the flat panel image. Hence, the performance of the amorphous silicon flat panel is much better than that of II. (a) (b)

Figure 1 Images of the wire type IQI on the 6mm Al specimen obtained at a magnification of 4 and using: (a) Image intensifier and (b) amorphous silicon flat panel. (a) (b) Figure 2 Plots, (a) and (b), of the lines crossing the IQI wires in the images (a) and (b) in Figure 1. 2.2 Comparison between the direct digital x-ray systems: amorphous silicon flat panel detector, CMOS detector, and reverse geometry x-ray system Figure 3 shows the images of the wire type IQI on the 6mm Al specimen obtained using different direct digital x-ray systems: (a) Flat panel detector (4X), (b) CMOS (1X), (c) Reverse geometry system (4X). The quality of the images is about the same: No.15 wire IQI detectable. The flat panel detector can detect the No. 16 IQI wire in real time (30 fps) at a magnification of 4 (see Figure 3(a)). However, the ghosting image is significant. It takes about 1 to 2 minutes for the CMOS linear detector and the reverse geometry system to generate an image. So, these two detectors are not suitable for the real-time wing inspection. Hence, amorphous silicon flat panels are more suitable to be used in the real-time inspection system. (a) (b)

( c ) Figure 3 Images of the wire type IQI on the 6mm Al specimen obtained using different x-ray systems: (a) Flat panel detector (4X), (b) CMOS (1X), (c) Reverse geometry system (4X) 2.3 Comparison between mini-focus x-ray tube and micro-focus x-ray tube Figure 4 shows the images of the wire type IQI on the 6 mm Al specimen obtained at the same magnification (4X) using (a) mini-focus x-ray tube and (b) micro-focus x-ray tube. In both the two images, the No. 15 wire IQI is detectable and the No. 16 wire IQI is barely detectable. Hence, at this magnification, both the mini-focus x-ray tube and the micro-focus tube can meet the sensitivity requirement. (a) (b) Figure 4 Images of the wire type IQI on the 6 mm Al specimen obtained at the same magnification (4X) using (a) mini-focus x-ray tube and (b) micro-focus x-ray tube. 3 Image enhancement for aircraft inspection Image enhancement allows more accurate interpretation of digital radiography indications. In

this paper, image enhancement methods are applied to improve image quality. Firstly the brightness of the image is adjusted using gamma correction, and then the local contrast of the image is improved using contrast limited adaptive histogram equalization to enhance perception of defects. Figure 5 shows the proposed image enhancement process. Gamma correction Contrast limited adaptive histogram equalization Figure 5 Proposed image enhancement process 3. 1 Gamma correction Gamma correction operation performs nonlinear brightness adjustment. Brightness for darker pixels is increased, but it is almost the same for bright pixels. As result more details are visible. 3. 2 Contrast limited adaptive histogram equalization HE transforms image pixels based on overall image statistics. Adaptive histogram equalization (AHE) involves selecting a local neighborhood centered around each pixel, calculating and equalizing the histogram of the neighborhood, and then mapping the centered pixel based on the new equalized local histogram [4]. For example, at each point in an input image we could consider a 8 8 window around that point. The 64-element histogram could then be used to determine a mapping function to histogram equalize that point based on the neighborhood. Since each point would be based on its own neighborhood, the mapping function can vary over the image. Contrast limited adaptive histogram equalization (CLAHE) seeks to reduce the noise produced in homogeneous areas by basic adaptive histogram equalization, and was originally developed for medical imaging, has been successful for the enhancement of portal images [5]. The homogeneous areas can be characterized by a high peak in the histogram associated with the contextual regions since many pixels fall inside the same gray range. With AHE, a local histogram is calculated and used to obtain the final value. High peaks in the histogram lead to large values in the final image because of integration. This problem can be corrected by limiting the amount of contrast enhancement at every pixel, which is achieved by clipping the original histogram to a limit. 3.3 Experiment Results We enhanced the radiographic images by Gamma correction and CLAHE. Applying Gamma correction on the image in Figure 6(a) and Figure 6(a) results in image that can be found in Figure6(c) and Figure7(c) Brightness for darker pixels is increased, and more details are visible. Then applying CLAHE on the image in Figure 6(a) and Figure 7(a) results in image that can be found in Figure 5(e) and Figure 6(e). The image contrast is improved.

(a) Original Image (b) Histogram of original image (c)image after Gamma correction (d)histogram after Gamma correction (e) Image after CLAHE (f) Histogram after CLAHE Figure 6 Image enhancement: radiographic image with crack

(a) Original Image (b) Histogram of original image (c)image after Gamma correction (d)histogram after Gamma correction (e) Image after CLAHE (f)histogram after CLAHE Figure 7 Image enhancement: radiographic image of aircraft wing

4. Conclusions In this paper, different x-ray systems were evaluated. The most essential difference between Real-time digital radiography systems is in the sensor technologies. All IIs are able to collect at 25 fps, hence are real time but noisier than DDs, and therefore would need significant magnification. CMOS linear detector and the reverse geometry detector to generate the images are not suitable for the real-time inspection. Thus, amorphous silicon flat panels are preferred for the aircraft inspection applications. Furthermore we proposed using Gamma correction and contrast limited adaptive histogram equalization to enhance digital radiographic images. They showed promising results on radiographic images. Gamma correction and CLAHE not only improved the local contrast of the radiographic images but also reduced the noise produced in homogeneous areas. Therefore, the proposed method can greatly enhance radiographic image and they will be helpful for defect recognition. 5. References [1]Halmshaw R., Industrial radiology: theory and practice, second edition, Chapman and Hall, UK, 1995. [2] Ewert, U., Zscherpel, U., Bavendiek, K., Replacement of Film Radiography by Digital Techniques and Enhancement of Image Quality Online NDT Journal, vol 12. No.6, 2007. [3] Bavendiek, K BAVENDIEK, Heike, U., Meade, W. D., Zscherpel, U. and U Ewert, U., New Digital Radiography Procedure Exceeds Film Sensitivity Considerably in Aerospace Applications, ECNDT 2006. [4] Pizer, S. M., Amburn, E. P., Austin, J. D., Cromartie, R., Geselowitz, A., ter Haar Romeny, B., Zimmerman, J. B. & Zuiderveld, K, Adaptive Histogram Equalization and Its variations, Comput. Vis. Graph. Image Process. 39, 355-368, 1987 [5] Rosenman, J., Roe, C. A., Cromartie, R., Muller, K. E. & Pizer, S. M. Portal film enhancement: Technique and clinical utility. Int. J. Radiat. Oncol. Biol. Phys. 25, 333-338, 1993.