INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS

Similar documents
CIR (Crush & Impact Resistant) VFD Power Cable

DLO Flexible Power Cable

VFD CABLES 100% EMI CONTAINMENT FOR INDUSTRIAL APPLICATIONS

VFD CABLES 100% EMI CONTAINMENT HIGHLY FLEXIBLE & DURABLE

n 100% EMI Emission Containment n Designed for Longer Service Life n Highly Flexible

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

GEXOL WORLD CLASS OIL & GAS CABLES

DOWNSTREAM POWER, CONTROL & INSTRUMENTATION CABLES

TIGER BRAND MINING CABLES

LV AIRGUARD. P r o ble m. ife? No S. a proven, rugged product for harsh environments

CORFLEX VFD CORFLEX VFD Part Number: Drive Cable

MEDIUM VOLTAGE

Low Voltage AIRGUARD. A proven, rugged product for harsh environments

14 AWG 2 AWG: 600 Volt

CCW. Continuously Corrugated Welded Cable. Armored Cable for Hazardous Locations

COMMON WORK RESULTS FOR INTEGRATED AUTOMATION DESIGN AND CONSTRUCTION STANDARD

OLFLEX. Flexible Tray Cable MARYLAND METRICS. LAPP products are available from

Instrumentation Cables

SIMpull THHN, it slips and slides - all with NoLube.

CATALOG OF PRODUCTS. Your Best Supplier of Electrical Cables

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70

THHN12STGN500 THHN 12 STR Green 500

Descriptions RoHS Compatible; Applicable Standard ASTM B3, ASTM B8, ASTM B787, Federal Specification A-A-59544, NFPA 70, NEMA WC-70

THHN12S0LWHBL500 THHN 12 Sol White/Blue Striped 500

THHN2BK2500 THHN 2 STR Black 2500

3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded (CCW) Type Cables*)

ÖLFLEX FORTIS 55 Highly Flexible and Extremely Oil-Resistant Tray Cable; -40 C Flexible/-55 C Stationary

Mongoose PT Platform Shale Shaker

THHN6WH500 THHN 6 STR White 500. Features Conductor Size Current Rating 55 AMPERE (60 DEG C), 65 AMPERE (75 DEG C), 75 AMPERE (90 DEG C)

OKONITE CABLES STOCK CATALOG In Stock for Immediate Delivery

SECTION WIRE AND CABLES. A. The CONTRACTOR shall provide wires and cable, complete and operable, in accordance with the Contract Documents.

3/C UL AIRGUARD UL Type MV-105 (Replacement for Continuously Corrugated and Welded Type Cables*)

GO... with the Leader! Advanced Digital Cable is the manufacturing leader of cable for the traffic industry

Extremely Oil-Resistant & Flexible Tray Cable with UL & CSA; Unshielded & Shielded. Complete the Installation. SKINTOP Strain Relief page 488

OFFSHORE CABLES GENERAL CATALOGUE. Offshore Cables. technergy INTEGRATED CABLING SOLUTIONS

Addison Medium Voltage Cables

CCW Continuously Corrugated Welded Cable ARMORED CABLE FOR HAZARDOUS LOCATIONS

600 Volt MULTICONDUCTOR XLPE MC Low Voltage Commercial & Industrial Cables

SUPERIOR MARINE CABLE SOLUTIONS

600 Volt MULTICONDUCTOR EPR MC Low Voltage Commercial & Industrial Cables

Electrical Characteristics Nominal electrical characteristics are shown in Table 1. Attenuation, Comply with ANSI T1.102; discrete values Table 1a.

WIRE & CABLE FILS ET CÂBLES ALAMBRES Y CABLES. 63 Technical information. 64 Primary Wire. 66 Brake Cable & Portable Extension Cable

METAL CLAD WIRING SYSTEM

SKINTOP ÖLFLEX CLICK & VFD CLICK FLEX. Products for Variable Frequency Drive Applications. ake the right connection

Airport Cables & Connectors

Product Index. 1 Copper Building Wire Products Flexiloy Aluminum Wire and Cable Products Power and Control Tray Cable Products 31 39

Over 35 Years of Service. Our Commitment. Dedicated to Our Customers. Product Expertise and Specialized Services. Strategic Partnerships

Republic Wire Inc. Our Raw Materials Make A Quality Difference. Diversity Of Products Meets Customer Needs

ÖLFLEX HEAT. Cable Solutions for Extreme Temperature

Underground System Design TADP 547

ENGINEERING COMMITTEE Interface Practices Subcommittee AMERICAN NATIONAL STANDARD ANSI/SCTE

ABOUT US ABOUT US 1 CRANE CABLES

5-46kV 3/C TRXLPE ARMORTEK Medium Voltage Commercial & Industrial Cables

Communication, Control, and Industrial Cable

Wire Gauge Chart. Cigar Lighter 10 to 12. Dome Light 1. Radio 2 to 4. Gauges 0.7 to 1. Instrument Lights 1.5 to 3

ÖLFLEX. Lift & Crane Cable LIFT & CRANE CABLE

VSD CABLES. KSXCY Series MDXCY Series HDXCY Series FDXCY Series P: (09)

Detailed Specifications & Technical Data

Detailed Specifications & Technical Data

EXTRA-PREMIUM GRADE PVC JACKET FOR EXTENDED CABLE LIFE. 24 AWG (0,23mm 2 ), 7/32 (7x0,20mm), Insulation Thickness: 0.010" (0,25mm)

Detailed Specifications & Technical Data

Creating. There is one basic question every customer needs to address when creating custom

Lutze Inc. Flexible Control Cables USA Selection Guide V. 2.6

Power Cables and their Application

Shrink temperature of 120 C. Rated for 600V, 90 C continuous use. T&B recommended up to 1kV. HS Series Specifications

Shrink temperature of 120 C. High-impact, abrasion, corrosion and chemical resistance. Rated for 600V, 90 C continuous use

Medium Voltage Power Cables

11-SDMS-03 REV. 02 SPECIFICATIONS FOR

5-35kV 1/C EPR MV-105 POWER (Tape Shield) Medium Voltage Commercial & Industrial Cables

Heat-Shrinkable Tubing

02 WIRE AND CABLE WIRE AND CABLE FILS ET CÂBLES ALAMBRES Y CABLES. Primary Wire Dispenser

ÖLFLEX HEAT. Cable Solutions for Extreme Temperature

A NEW WAVE OF DATA AND ENERGY MARINE AND OFFSHORE CABLES

Screened servo cable with PUR outer sheath for highly dynamic power chain application - certified

For tough, seaworthy wire

SECTION ELECTRICAL IDENTIFICATION

HO7RN-F 450/750V BS EN Highly Flexible Rubber Cable

A. Product Description: Stranded conductor insulated wire.

Data sheet. Connection line M12 plug straight - M12 jack straight drag chain suitable, 8-pole, X-coded 2.0 m. Illustrations

2. CONDUCTORS. 2.1 Strand Types. 2.2 Coatings Tensile Strength of Copper Wire Copper Strand Properties. 2.5 Aluminum Strand Properties

Conductors and Raceway Design

SPECIFICATION SS-140/9. 0.6/1 (1.2) kv CONTROL AND POWER UNDERGROUND CABLES WITH PVC OR XLPE INSULATION AND PVC JACKET

Contents. Introduction 3 Cable Components 4 Cable Handling 8 Health, Safety and Environment 9 Quick Reference Guide 10 Underground Mining - Coal 12

High Performance Wire and Cable

Y-CY-JZ flexible, CU-screened, transparent, EMC-preferred type, meter marking

CONTINUING EDUC ATION

IMSA TRAFFIC SIGNAL CABLE

Field Instrument Cable. Electrical Noise

Armoured Power and Control Cables to BS7917

SPEC 44. Wire and cable

5-46kV 3/C TRXLPE POWER CSA Medium Voltage Commercial & Industrial Cables

Sample Specification Electrical Heat Tracing Cables Metric Units

Article 250 Grounding & Bonding

Armoured Power and Control Cables Fire Resistant

SECTION MEDIUM-VOLTAGE CABLES

MV-105 Power. (Tape Shield) 5-35kV 1/C EPR. Design Parameters. Description. Options. Installations

Industrial Automation & Control Cables

American Electrical Institute

WIRE & CABLE. 99 Wire Low fire hazard wire and cable

Cores layed up around conductive filler with aramid rope in the center Rubber, special compound, mechanical properties acc.

Transcription:

INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS

Industrial Cable Index n DLO Power Cables DLO Flexible Power Cable................................ 2-3 n Type W Cables Type W 1/C Motor Lead Cable............................. 4-5 Type W 2/C Magnet Crane Cable........................... 6-7 Type W 3/C P&R Cable.................................. 8-9 Type W 4/C P&R Cable................................ 10-11 n Variable Frequency Drive (VFD) Power Cables Extra Flexible VFD Power Cable........................... 12-13 CIR (Crush & Impact Resistant) VFD Power Cable.............. 14-15 TC-ER Flexible VFD Power Cable.......................... 16-17 Medium Voltage Type VFD/MV-105 Power Cable.............. 18-19 n Ship-to-Shore Power Cables Enhanced THOF-500 Power Cable........................... 20 Enhanced PLUS THOF-500 Power Cable....................... 21 n Grounds and Jumpers Flexible Grounding Cable................................. 22 Lead Covered Grounding Cable............................. 23 Red Jumper......................................... 24-25 n Mobile Substation Power Cable (Type SH).................. 26-27 n Factory Installed Cable Assemblies.......................... 28 n Renewable Energy Cables................................. 29 Nexans AmerCable believes the information presented throughout this catalog to be reliable and current. All information is subject to change without notice. The information listed is approximate, and is presented only as a guide for product selection. We make no claims or warranties for the suitability of any product for any particular application. AmerCable is a registered trademark of AmerCable Incorporated Made in America 2017, AmerCable Incorporated

Harsh operating environments require cables engineered for longer service life No matter what type of environment you operate in, Nexans AmerCable has a cable productivity solution for you. Our innovatively engineered and manufactured Industrial Cable Family is designed for your toughest conditions. As a leading producer of industrial cables in North America, Nexans AmerCable is dedicated to producing: n cables that last longer in difficult operating environments n cables designed to help provide greater levels of safety and productivity CABLE INNOVATION n Designing insulating and jacketing materials that are more flexible with greater resistance to abrasion and moisture n Cable constructions that last longer providing reduced down time for increased productivity n New product development that addresses environmental, safety and cost reduction issues specific to your application. OPERATING EXCELLENCE n The industry leader in on-time delivery. For our current delivery rate, visit our website at www.amercable.com n Standard lead-time of 8 to 10 weeks n Urgent response shipment capability of 2 to 4 weeks n AmerCable is an ISO-9001 certified manufacturer HANDS-ON FIELD SUPPORT Our experienced field application engineers are available for on-site evaluation and solutions. They also conduct education and training sessions that address safety, splicing and cable handling issues. www.nexansamercable.com e-mail: industrial@nexansamercable.com 1

37-119 FLEXIBLE POWER CABLE DLO 2000 VOLTS 90 C DIESEL LOCOMOTIVE CABLE LIMITED SMOKE (SIZES 2/0 AND HIGHER) EP/CPE RHH, RHW-2 Flexible-stranded, tin-coated annealed copper Flame retardant, oil and sunlight resistant Chlorinated Polyethylene (CPE) See below for jacket color options (Special order) RATINGS & APPROVALS Separator Suitable separator tape provides easy stripping of insulation Ethylene-Propylene rubber (EPR) n ICEA S-95-658/ NEMA WC-70: Nonshielded Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy n UL Standard 44: Thermoset Insulated Wires & Cables, Types RHH, RHW-2. UL VW-1 n UL Standard 1685: Vertical Tray Fire propagation and Smoke Release Test for Electrical and optical Fiber Cables. (UL,ST-1) n ASTM B-33: Standard Specification for Tinned Soft or Annealed Copper Wire for Electrical Purposes n ASTM B-172: Standard Specification for Rope-Lay-Stranded Copper s having Bunch-Stranded Members, for Electrical s n MSHA P-184 n RoHS Compliant APPLICATION Nexans AmerCable s 2000V Diesel Locomotive Cable (DLO) is a single conductor portable power cable suitable for use in applications needing great flexibility, excellent wearability and good flex life. Applications include locomotive and car equipment, motor and generator leads, battery leads, shipyards, telecommunications power, heavy earth moving equipment, renewable energy and other heavy duty flexing applications. FEATURES n A two layer composite of flame retardant, oil and sunlight resistant Chlorinated Polyethylene (CPE) outer layer and Ethylene- Propylene rubber (EPR) inner layer. The composite design provides significant diameter reductions compared to designs using full thickness jackets. n Suitable for continuous operating temperatures of 90 C, wet or dry n Rated RHH, RHW-2; 2/0 1111 kcmil listed and marked for CT use n UL listed as Sunlight Resistant n UL listed as Marine Shipboard Cable (4/0 and larger) Special order only n and jacket meet hazardous waste regulations, per Code of Federal Regulations 40 Section 261 (40CFR261) for characteristic lead content n Flame Resistance: FT-4/IEEE1202 for 2/0 1111 kcmil and UL VW-1 n Meets smoke release and other requirements of Vertical Cable Tray Test UL 1685 and is marked ST-1 for 2/0 1111 kcmil n Extremely flexible stranding used for increased flexibility and ease of installation 2 Manufactured by Nexans AmerCable (870) 862-4919 (800) 643-1516 Fax (870) 862-9613

37-119 SINGLE CONDUCTOR PORTABLE POWER CABLE DLO Part No. 37-119- Size AWG/ kcmil Minimum Wires per Outside Diameter Approx. Weight lbs. per 1,000 ft. *Ampacity 90 C 201 14 19 0.045 0.015 0.214 31 35 202 12 19 0.045 0.015 0.233 41 40 203 10 37 0.045 0.015 0.257 58 55 204 8 168 0.055 0.030 0.349 77 80 205 6 61 0.055 0.030 0.365 124 105 207 4 133 0.055 0.030 0.460 203 140 209 2 259 0.055 0.030 0.534 265 190 210 1 224 0.065 0.045 0.623 415 220 211 1/0 266 0.065 0.045 0.668 489 260 212 2/0 323 0.065 0.045 0.689 562 300 213 3/0 418 0.065 0.045 0.771 757 350 214 4/0 532 0.065 0.045 0.822 894 405 215 262 646 0.075 0.065 0.957 1091 467 216 313 777 0.075 0.065 1.008 1245 522 217 373 925 0.075 0.065 1.074 1486 591 218 444 1110 0.075 0.065 1.143 1749 652 219 535 1332 0.090 0.065 1.257 2099 728 220 646 1591 0.090 0.065 1.361 2464 815 221 777 1924 0.090 0.065 1.439 2899 904 222 929 2318 0.090 0.065 1.685 3501 1005 223 1111 2745 0.130 0.065 1.850 4166 1119 * Ampacity Calculated with at 90 C conductor temperature and 30 C ambient air, per 2008 NEC, Table 310.17 Cable diameters are subject to +/-5% manufacturing tolerance SAVE TIME Order Your Type W Cable with Factory Installed Connectors SAVE MONEY www.nexansamercable.com e-mail: industrial@nexansamercable.com 3

37-401 PORTABLE POWER CABLE TYPE W SINGLE CONDUCTOR 600-2000 VOLTS MOTOR LEAD CABLE 90 C Bunched strands of tinned annealed copper per ASTM B-33 Separator A suitable separator provides for easy stripping of insulation Reinforcement Polypropylene reinforcing braid provides long flex life RATINGS & APPROVALS Ethylene-Propylene rubber (EPR) per ICEA S-95-658, and ASTM D-2802 Flame retardant, oil and sunlight resistant Chlorinated Polyethylene (CPE). Black standard. See below for other color options. n UL listed as Type W n ASTM B-33: Standard Specification for Tinned Soft or Annealed Copper Wire for Electrical Purposes n ASTM D-2802: Standard Specification for Ozone- Resistant Ethylene-Alkene Polymer for Wire and Cable n ICEA S-95-658/ NEMA WC-70: Nonshielded Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy n MSHA P-184 for 6 AWG and above APPLICATION Nexans AmerCable s 600-2000 Volt single-conductor motor-lead cables are recommended for installations where long flex life, great flexibility and wearability are desired. Applications include heavy duty or temporary power supply service, AC or DC, to motor or generators, portable and stationary heavy duty equipment, cranes, conveyors and other mobile equipment. They may be installed in air, in ducts, immersed in water or directly buried in the earth. However, they are not UL Type USE. For cables requiring reduced flame propagation, refer to the factory. FEATURES n Suitable for continuous operating temperatures of 90 C n Suitable for use in festoons, suspended loops and power tracks n Suitable for use on Payout and Retractable reels (P&R) n Heavy duty jacket offers excellent protection against abrasion, impact, heat, oil, flame, ozone, alkali and acids. n Extremely flexible stranding used for increased flexibility and ease of installation n Dual Rated 600V and 2kV n Suitable for extra hard usage which enhances performance Type W CPE jackets are available in highly visible colors without sacrificing performance 4 Manufactured by Nexans AmerCable (870) 862-4919 (800) 643-1516 Fax (870) 862-9613

37-401 SINGLE CONDUCTOR PORTABLE POWER CABLE TYPE W Part No. 37-401- Size AWG/ kcmil Minimum Wires per Outside Diameter 008 8 133 0.060 0.075 0.460 136 80 006 6 133 0.060 0.095 0.550 202 105 004 4 133 0.060 0.095 0.600 268 140 003 3 133 0.060 0.095 0.620 318 165 002 2 259 0.060 0.095 0.690 375 190 001 1 259 0.080 0.095 0.760 479 220 010 1/0 266 0.080 0.095 0.810 555 260 020 2/0 323 0.080 0.095 0.832 675 300 030 3/0 418 0.080 0.095 0.900 794 350 040 4/0 532 0.080 0.095 0.960 959 405 250 250 627 0.095 0.095 1.070 1268 455 300 300 741 0.095 0.095 1.100 1315 505 350 350 888 0.095 0.095 1.160 1517 570 400 400 999 0.095 0.095 1.190 1681 615 500 500 1221 0.095 0.095 1.310 2039 700 * Ampacity is calculated with a 90 C conductor temperature and 30 C ambient air, per 2008 NEC, Table 400.5(B) Cable diameters and weights are subject to +/- 5% manufacturing tolerance Approx. Weight lbs. per 1,000 ft. *Ampacity 90 C SAVE TIME Order Your Type W Cable with Factory Installed Connectors SAVE MONEY www.nexansamercable.com e-mail: industrial@nexansamercable.com 5

37-430 MAGNET CRANE CABLE TYPE W TWO CONDUCTOR 600-2000 VOLTS MAGNET CRANE CABLE 90 C s Bunched strands of tinned annealed copper per ASTM B-33. Stranding other than those listed in the table are available upon special order. Ethylene-Propylene rubber (EPR) per ICEA S-95-658 and ASTM D-2802. material color coded through AWG size #2. Larger sizes are coded with fabric tape wraps. One black, one white. RATINGS & APPROVALS Separator A suitable separator provides for easy stripping of insulation Fillers Fibrous filler provides great impact resistance and flexibility. Rubber fillers are available upon special order. Flame retardant, oil and sunlight resistant Chlorinated Polyethylene (CPE). Black standard. See below for other color options. n UL listed as Type W n UL listed as Type TC n ASTM B-33: Standard Specification for Tinned Soft or Annealed Copper Wire for Electrical Purposes n ASTM D-2802: Standard Specification for Ozone- Resistant Ethylene-Alkene Polymer for Wire and Cable n ICEA S-95-658/ NEMA WC-70: Nonshielded Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy n MSHA P-184 n Flame Resistance: FT-4 APPLICATION Nexans AmerCable s 600-2000 Volt two conductor cables are recommended for installations where long flex life, great flexibility and wearability are desired. Applications include heavy duty or temporary power supply service, AC or DC, to motor or generators, portable and stationary heavy duty equipment, cranes, conveyors and other mobile equipment. They are especially recommended to supply power for magnet crane applications. They may be installed in air, in ducts, immersed in water or directly buried in the earth. However, they are not UL Type USE. For cables requiring reduced flame propagation, refer to the factory. FEATURES n Suitable for continuous operating temperatures of 90 C n Suitable for use in festoons, suspended loops and power tracks n Suitable for use on Payout and Retractable reels (P&R) n Heavy duty jacket offers excellent protection against abrasion, impact, heat, oil, flame, ozone, alkali and acids. n Extremely flexible stranding used for increased flexibility and ease of installation n Dual Rated 600V and 2kV n Suitable for extra hard usage which enhances performance Type W CPE jackets are available in highly visible colors without sacrificing performance 6 Manufactured by Nexans AmerCable (870) 862-4919 (800) 643-1516 Fax (870) 862-9613

37-430 TWO CONDUCTOR MAGNET CRANE TYPE W ROUND Part No. 37-430- Size AWG/ kcmil Minimum Wires per Outside Diameter Approx. Weight lbs. per 1,000 ft. *Ampacity 90 C 008 8 133 0.060 0.109 0.830 369 74 006 6 133 0.060 0.109 0.960 518 99 004 4 133 0.060 0.109 1.080 715 130 002 2 259 0.060 0.141 1.280 1045 174 010 1/0 266 0.080 0.156 1.560 1464 234 020 2/0 342 0.080 0.156 1.660 1788 271 040 4/0 532 0.080 0.172 1.973 2530 361 250 250 627 0.095 0.165 2.100 2664 402 350 350 888 0.095 0.176 2.360 3854 495 500 500 1221 0.095 0.214 2.700 5191 613 * Ampacity is calculated with a 90 C conductor temperature and 30 C ambient air, per 2008 NEC, Table 400.5(B) Cable diameters and weights are subject to +/- 5% manufacturing tolerance A full line of UL listed Type G cables with grounding conductors is available. Consult factory. SAVE TIME Order Your Type W Cable with Factory Installed Connectors SAVE MONEY Photo provided by NASCOOP www.nexansamercable.com e-mail: industrial@nexansamercable.com 7

37-431 PORTABLE POWER CABLE TYPE W THREE CONDUCTOR 600-2000 VOLTS QUALIFIED FOR P&R REELING SERVICE 90 C s Bunched strands of tinned annealed copper per ASTM B33. Stranding other than those listed in the table are available upon special order. Fillers Fibrous filler provides great impact resistance and flexibility. Rubber fillers are available upon special order. Flame retardant, oil and sunlight resistant Chlorinated Polyethylene (CPE). Reinforced, two layer jacket construction is used on AWG size 1/0 and larger cables. Black standard. Consult factory for colored jackets. Ratings & Approvals Separator A suitable separator provides for easy stripping of insulation Ethylene-Propylene rubber (EPR) per ICEA S-95-658, also meeting ASTM D- 2802. material color coded through AWG size #2. Larger sizes are coded with fabric tape wraps. One black, one white, one green. Reinforcement Polypropylene reinforcing braid provides long flex life n UL listed as Type W n UL listed as Type TC-ER n ASTM B-33: Standard Specification for Tinned Soft or Annealed Copper Wire for Electrical Purposes n ASTM D-2802: Standard Specification for Ozone- Resistant Ethylene-Alkene Polymer for Wire and Cable n ICEA S-95-658/ NEMA WC-70: Nonshielded Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy n MSHA P-184 n Flame Resistance: FT-4 Type W CPE jackets are available in highly visible colors without sacrificing performance APPLICATION Nexans AmerCable s 600-2000 Volt three conductor cables are recommended for installations where long flex life, great flexibility and wearability are desired. Applications include heavy duty or temporary power supply service, AC or DC, to motor or generators, portable and stationary heavy duty equipment, cranes, conveyors and other mobile equipment. They are also recommended for use on Payout and Retractable reels, festoons, suspended loops and power tracks. They may be installed in air, in ducts, immersed in water or directly buried in the earth. However, they are not UL Type USE. For cables requiring reduced flame propagation, refer to the factory. Features n Suitable for continuous operating temperatures of 90 C n Suitable for use in festoons, suspended loops and power tracks n Suitable for use on Payout and Retractable reels (P&R) n Heavy duty jacket offers excellent protection against abrasion, impact, heat, oil, flame, ozone, alkali and acids. n Extremely flexible stranding used for increased flexibility and ease of installation n Dual Rated 600V and 2kV n Suitable for extra hard usage which enhances performance n Meets crush and impact requirements for Type MC cable. UL Type TC-ER APPROVED! 8 Manufactured by Nexans AmerCable (870) 862-4919 (800) 643-1516 Fax (870) 862-9613

37-431 TYPE W ROUND 600-2000 VOLTS Part No. 37-431- Size AWG/ kcmil Minimum Wires per Outside Diameter Approx. Weight lbs. per 1,000 ft. 008 8 133 0.060 0.141 0.930 513 65 006 6 133 0.060 0.141 1.025 643 87 004 4 133 0.060 0.125 1.200 962 114 002 2 259 0.060 0.141 1.340 1295 152 010 1/0 266 0.080 0.156 1.665 1967 205 020 2/0 323 0.080 0.156 1.75 2260 237 030 3/0 418 0.080 0.156 1.900 2863 274 040 4/0 532 0.080 0.172 2.050 3381 316 250 250 627 0.095 0.250 2.395 4375 352 350 350 888 0.095 0.259 2.684 5562 433 500 500 1221 0.095 0.290 3.030 7408 536 * Ampacity is calculated with a 90 C conductor temperature and 30 C ambient air, per 2008 NEC, Table 400.5(B) Cable diameters and weights are subject to +/- 5% manufacturing tolerance A full line of UL listed Type G cables with grounding conductors is available. Consult factory. *Ampacity 90 C SAVE TIME Order Your Type W Cable with Factory Installed Connectors SAVE MONEY www.nexansamercable.com e-mail: industrial@nexansamercable.com 9

37-432 PORTABLE POWER CABLE TYPE W FOUR CONDUCTOR 600-2000 VOLTS SUITABLE FOR P&R REELING SERVICE 90 C s Bunched strands of tinned annealed copper per ASTM B-33. Strandings other than those listed in the table are available upon special order. Fillers Fibrous filler provides great impact resistance and flexibility. Rubber fillers are available upon special order. Flame retardant, oil and sunlight resistant Chlorinated Polyethylene (CPE). Black standard. Consult factory for colored jackets. RATINGS & APPROVALS Separator A suitable separator provides for easy stripping of insulation Ethylene-Propylene rubber (EPR) per ICEA S-95-658, also meeting ASTM D- 2802. material color coded through AWG size #2. Larger sizes are coded with fabric tape wraps. One black, one red, one white, one green. Reinforcement Polypropylene reinforcing braid provides long flex life n UL listed as Type W n UL listed as Type TC-ER n ASTM B-33: Standard Specification for Tinned Soft or Annealed Copper Wire for Electrical Purposes n ASTM D-2802: Standard Specification for Ozone- Resistant Ethylene-Alkene Polymer for Wire and Cable n ICEA S-95-658/ NEMA WC-70/: Nonshielded Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy n MSHA P-184 n Flame Resistance: FT-4 Type W CPE jackets are available in highly visible colors without sacrificing performance APPLICATION Nexans AmerCable s 600-2000 Volt four conductor cables are recommended for installations where long flex life, great flexibility and wearability are desired. Applications include heavy duty or temporary power supply service, AC or DC, to motor or generators, portable and stationary heavy duty equipment, cranes, conveyors and other mobile equipment. They are also recommended for use on Payout and Retractable reels, festoons, suspended loops and power tracks. They may be installed in air, in ducts, immersed in water or directly buried in the earth. However, they are not UL Type USE. For cables requiring reduced flame propagation, refer to the factory. FEATURES n Suitable for continuous operating temperatures of 90 C n Suitable for use in festoons, suspended loops and power tracks n Suitable for use on Payout and Retractable reels (P&R) n Heavy duty jacket offers excellent protection against abrasion, impact, heat, oil, flame, ozone, alkali and acids n Extremely flexible stranding used for increased flexibility and ease of installation n Dual Rated 600V and 2kV n Suitable for extra hard usage which enhances performance n Meets crush and impact requirements for Type MC cable. UL Type TC-ER APPROVED! 10 Manufactured by Nexans AmerCable (870) 862-4919 (800) 643-1516 Fax (870) 862-9613

37-432 FOUR CONDUCTOR PORTABLE POWER CABLE TYPE W ROUND Part No. 37-432- Size AWG/ kcmil Minimum Wires per Outside Diameter Approx. Weight lbs. per 1,000 ft. *Ampacity 90 C 008 8 133 0.060 0.141 1.020 601 65 006 6 133 0.060 0.141 1.135 801 87 004 4 133 0.060 0.125 1.240 1138 114 002 2 259 0.060 0.125 1.490 1663 152 010 1/0 266 0.080 0.156 1.810 2471 205 020 2/0 323 0.080 0.156 1.940 2975 237 040 4/0 532 0.080 0.156 2.260 4376 316 250 250 627 0.095 0.270 2.665 5725 352 350 350 888 0.095 0.290 3.000 7428 433 500 500 1221 0.095 0.310 3.425 10010 536 * Ampacity is calculated with a 90 C conductor temperature and 30 C ambient air, per 2008 NEC, Table 400.5(B) Cable diameters and weights are subject to +/- 5% manufacturing tolerance For more than four conductors, consult factory A full line of UL listed Type G cables with grounding conductors is available. Consult factory. SAVE TIME Order Your Type W Cable with Factory Installed Connectors SAVE MONEY www.nexansamercable.com e-mail: industrial@nexansamercable.com 11

37-102VFD EXTRA FLEXIBLE VFD POWER CABLE GEXOL INSULATED THREE CONDUCTOR 2KV RATED 110 C Power s (x3) Soft annealed flexible stranded tinned copper per IEEE 1580 Table 11. (2kV) Gexol cross-linked flame retardant polyolefin, meeting the requirements for Type P of IEEE 1580 and Type X110 of UL 1309/CSA 245. Color: Gray with printed phase I.D. (Black-White-Red) A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL1309/ CSA 245 and IEEE 1580. Armor (Optional) Tinned copper basket weave wire armor per IEEE 1580 and UL 1309/CSA 245. Ground s (x3) Soft annealed flexible stranded tinned copper per IEEE 1580 Table 11. Gexol insulated and sized per UL 1277. Color: Green Shield Overall tinned copper braid plus aluminum/polyester tape providing 100% coverage. Sheath (Optional) A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 1309/CSA 245 and IEEE 1580. Note: For armored versions the braid is placed between the inner jacket and outer sheath where it serves as both the EMI shield and armor. RATINGS & APPROVALS n 110 C Temperature Rating n UL Listed as Marine Shipboard Cable: (E111461) n UL Listed as Type TC-ER (E123629) n United States Coast Guard: November 2, 1987 / 9304 n CSA listed as Marine Shipboard Cable (82346) n Flame resistance: IEEE 1202/FT-4 n Sunlight resistant Halogen-Free and Fire Resistant constructions available by request. Gexol is a registered trademark of AmerCable Incorporated APPLICATION A flexible, braid and foil shielded, 2kV power cable specifically engineered for use in variable frequency AC motor drive (VFD) applications. FEATURES n Specially engineered cable design produces a longer cable life in VFD applications. n Overall braid plus foil shield is engineered with 100% coverage and a surface transfer impedance <50 milliohms at 10MHz to contain EMI. n Symmetrical insulated ground conductors reduce induced voltage imbalances and carry common mode noise back to the drive. n High strand count conductors and braid shield design is much more flexible, easier to install and more resistant to vibration than Type MC cable. n Gexol s lower dielectric constant (standard XLPEs, EPRs and other Type P insulation materials have higher dielectric constants) reduces reflected wave peak voltage magnitudes. This allows for longer output cable distances and minimizes the effect of high frequency noise induced into the plant ground system. n 2kV insulation thickness is used to resist the potential 2-3x reflected voltages experienced in 600V VFD applications. n Dual certified IEEE 1580 Type P and UL 1309/CSA 245 Type X110. n Highest ampacity ratings: ABS 100 C, DNV 95 C, LRS 95 C, Transport Canada 95 C. n Severe cold durability: exceeds CSA cold bend/cold impact (-40 C/-35 C). n Flame retardant: IEC 332-3 Category A and IEEE 1202. n Optional braid armor of bronze, aluminum or tinned copper. 12 Manufactured by Nexans AmerCable (870) 862-4919 (800) 643-1516 Fax (870) 862-9613

37-102VFD EXTRA FLEXIBLE VFD POWER CABLE GEXOL INSULATED Unarmored Armored & Sheathed (TS) Grounding Size Weight Weight * NEC Ampacities AWG/ Part No. Diameter Lbs./ Part No. Diameter Lbs./ Size In In In kcmil mm 2 37-102 Inches* 1000 Ft. 37-102 Inches* 1000 Ft. (AWG) Free Air Cable Tray Conduit 4 21-312VFD 1.100 925-312TSVFD 1.262 1138 12 114 95 89 2 34-314VFD 1.235 1421-314TSVFD 1.392 1512 10 152 130 119 1 43-315VFD 1.340 1517-315TSVFD 1.509 1851 10 177 150 137 1/0 54-316VFD 1.450 1803-316TSVFD 1.615 2136 10 205 170 163 2/0 70-317VFD 1.580 2120-317TSVFD 1.792 2660 10 237 195 186 3/0 86-318VFD 1.750 2827-318TSVFD 1.959 3269 8 274 225 214 4/0 109-319VFD 1.900 3416-319TSVFD 2.101 3864 8 316 260 253 262 132-320VFD 2.050 4210-320TSVFD 2.258 4661 6 362 297 286 313 159-321VFD 2.130 5105-321TSVFD 2.353 5325 6 404 328 324 373 189-322VFD 2.275 5521-322TSVFD 2.483 6674 6 449 364 357 444 227-323VFD 2.425 6440-323TSVFD 2.634 6994 6 497 402 396 535 273-324VFD 2.643 7547-324TSVFD 2.931 8477 6 556 446 441 646 326-326VFD 2.920 8916-326TSVFD 3.178 9888 4 617 496 489 777 394-327VFD 3.102 10909-327TSVFD 3.510 11803 4 688 546 537 Cable diameters are subject to a +/- 5% manufacturing tolerance Ampacity In Free Air: Based on 90 C conductor temperature and 30 C ambient temperature per 2008 NEC Table B.310.3 Ampacity In Cable Tray: Based on 90 C conductor temperature and 30 C ambient temperature per 2008 NEC Table 310.16 Ampacity In Conduit: Based on 90 C conductor temperature and 30 C ambient temperature per 2008 NEC Table B.310.1 IEEE ampacities are based on IEEE Std. 45 with a 45 C ambient and arranged in a single bank per hanger. For those instances where cable must be double banked, the ampacities should be multiplied by 0.8. *3 Grounding s Green Insulated www.nexansamercable.com e-mail: industrial@nexansamercable.com 13

37-102 CIRVFD CIR (CRUSH & IMPACT RESISTANT) VFD POWER CABLE GEXOL INSULATED THREE CONDUCTOR 2KV RATED 90 C UL LISTED AS TYPE TC-ER Power s (x3) Soft annealed flexible stranded tinned copper per ASTM B-33. Gexol chemically crosslinked, non-chlorinated flame retardant polyolefin meeting the requirements per UL 1277. Color: Gray with printed phase I.D. Crush & impact resistant, flame retardant, oil, abrasion, chemical and sunlight resistant thermoplastic compound meeting UL 1277. CIR RATINGS & APPROVALS Gexol and CIR are registered trademarks of AmerCable Incorporated Ground s (x3) Soft annealed tinned copper per ASTM B-33 flexible stranding with 600/1000V Gexol insulation sized per UL 1277. Color: Green Shield Overall tinned copper braid plus aluminum/polyester tape providing 100% coverage. Safe to Handle CIR is a safe, flexible alternative to metal-clad cables. n 90 C temperature rating n UL listed as Type TC-ER (E123629) n Flame Retardant IEEE 1202/FT-4 n Suitable for use in Class I, Div 2 and Zone 2 environments n UL listed as Marine Shipboard Cable (E111461) n Sunlight resistant n Direct burial APPLICATION A flexible, braid and foil shielded, 2kV power cable specifically engineered for use in variable frequency AC motor drive (VFD) applications. FEATURES n Specially engineered cable design produces a longer cable life in VFD applications. n Overall braid plus foil shield is engineered with 100% coverage and a surface transfer impedance <50 milliohms at 10MHz to contain EMI. n Symmetrical insulated ground conductors reduce induced voltage imbalances and carry common mode noise back to the drive. n High strand count conductors and braid shield design is much more flexible, easier to install and more resistant to vibration than Type MC cable. n Gexol s lower dielectric constant (standard XLPEs, EPRs and other Type P insulation materials have higher dielectric constants) reduces reflected wave peak voltage magnitudes. This allows for longer output cable distances and minimizes the effect of high frequency noise induced into the plant ground system. n 2kV insulation thickness is used to resist the potential 2-3x reflected voltages experienced in 600V VFD applications. n Passes the same stringent crush and impact testing required by UL 2225 for Type MC-HL n Gas & vapor tight impervious to water and air n Smaller bend radius (up to 40% smaller) than Type MC n Reduced tray fill (up to 35% less) compared to Type MC n Considerably more flexible than Type MC n Reduced installation time and cost compared to Type MC n Glands for this product cost up to 50% LESS than those for Type MC 14 Manufactured by Nexans AmerCable (870) 862-4919 (800) 643-1516 Fax (870) 862-9613

37-102 CIRVFD 2000 VOLTS CRUSH & IMPACT RESISTANT DC Resist. AC Resist. Inductive Voltage Drop Green NEC Ampacities Size Weight @ 25 C @ 90 C, 60 Hz Reactance @ 90 C Insulated AWG/ Part No. Diameter (Lbs./ (Ohms/ (Ohms/ (Ohms/ (Volts/Amp/ Grounding* In In In kcmil mm 2 37-102 Inches* 1000 Ft.) 1000 Ft.) 1000 Ft.) 1000 Ft.) 1000 Ft.) Size (AWG) Free Air Cable Tray 14 2.1-508CIRVFD 0.768 297 2.907 3.635 0.040 5.073 18 15 15 15 12 3.3-516CIRVFD 0.792 376 1.826 2.283 0.038 3.199 18 20 20 20 10 5.2-308CIRVFD 0.888 492 1.153 1.441 0.036 2.032 14 30 30 30 8 7.6-309CIRVFD 0.926 560 0.708 0.885 0.037 1.263 14 65 55 48 6 12.5-310CIRVFD 1.051 826 0.445 0.556 0.033 0.804 12 87 75 65 4 21-312CIRVFD 1.093 945 0.300 0.376 0.031 0.552 12 114 95 89 2 34-314CIRVFD 1.225 1298 0.184 0.230 0.029 0.348 10 152 130 119 1/0 54-316CIRVFD 1.447 1908 0.117 0.147 0.029 0.234 10 205 170 163 2/0 70-317CIRVFD 1.566 2287 0.093 0.117 0.028 0.192 10 237 195 186 4/0 109-319CIRVFD 1.874 3360 0.058 0.075 0.027 0.132 8 316 260 253 262 132-320CIRVFD 2.031 4200 0.048 0.063 0.027 0.115 6 362 297 286 373 189-322CIRVFD 2.257 5634 0.034 0.045 0.025 0.088 6 449 364 357 535 273-324CIRVFD 2.705 7853 0.024 0.033 0.026 0.072 6 556 446 441 777 394-327CIRVFD 3.102 11137 0.016 0.025 0.025 0.060 4 688 546 537 Cable diameters are subject to a +/- 5% manufacturing tolerance Ampacity In Free Air: Based on 90 C conductor temperature and 30 C ambient temperature per 2008 NEC Table B.310.3 Ampacity In Cable Tray: Based on 90 C conductor temperature and 30 C ambient temperature per 2008 NEC Table 310.16 Ampacity In Conduit: Based on 90 C conductor temperature and 30 C ambient temperature per 2008 NEC Table B.310.1 *3 Grounding s Green Insulated *Cable diameters are subject to a +/- 5% manufacturing tolerance NEC ampacities are based on Table 310.15 (B) (16) of the National Electrical Code (NEC) for conductors rate 90 C, in a multi-conductor cable, at an ambient temperature of 30 C. The 75 C column is provided for additional information. The ampacities shown apply to open runs of cable, installation in any approved raceway. Derating for more than three current carrying conductors within the cable is in accordance with NEC Table 310.15 (B) (3) (a). The ampacities shown also apply to cables installed in cable tray in accordance with NEC Section 392.80. CIR VFD Stranding Profile Closest Equivalent Uninsulated Size Number IEEE 45 Metric Size AWG/kcmil of Strands Std. Size (mm2) Dia. (inches) 14 12 10 8 6 4 2 1 1/0 2/0 3/0 4/0 262 313 373 444 535 646 777 19 19 37 37 61 133 133 209 266 342 418 532 646 777 925 1110 1332 1591 1924 4 6 10 16 26 41 66 83 106 133 168 212 262 313 373 444 535 646 777 2.08 3.29 5.23 7.57 12.49 21.11 33.51 42.79 54.45 70.01 85.57 108.91 132.25 159.06 189.36 227.23 272.68 325.70 393.87 0.074 0.093 0.113 0.136 0.175 0.258 0.324 0.361 0.407 0.461 0.510 0.575 0.654 0.720 0.785 0.860 0.941 1.029 1.132 www.nexansamercable.com e-mail: industrial@nexansamercable.com 15

37-108VFD FLEXIBLE TC-ER VFD POWER CABLE THREE CONDUCTOR 90 C 600V Power s (x3) Soft annealed flexible stranded tinned copper per ASTM B-33 Cross-linked, flexible, low dielectric constant compound rated 90 C. Sizes larger than 4/0 AWG individual conductors colored black with conductor number surface printed in contrasting ink. Sizes 4/0 AWG and smaller individually colored conductors red, white,black. Flame retardant, moisture and sunlight resistant Polyvinyl Chloride (PVC). Colored black. Symmetrical Ground s (x3) Three symmetrically placed flexible stranded tinned copper conductors in direct contact with the shield. Metallic Shield Sizes 8 AWG and Larger Helically applied bare copper tape. Sizes Smaller than 8 AWG in-coated copper braid plus aluminum/polyester tape. Both shielding systems provide 100% coverage. TC-ER RATINGS & APPROVALS n UL Listed as Type TC-ER 600V n UL Listed as 1000V flexible motor supply cable (up to 4/0 AWG) n 90 C Temperature Rating n FT-4 and IEEE 1202 flame ratings n Sunlight resistant n Direct burial APPLICATION A flexible, shielded power cable specifically engineered for use in variable frequency AC motor drive (VFD) applications. FEATURES n Specially engineered cable design produces a longer cable life in VFD applications. n Overall shield provides 100% coverage containing VFD EMI emissions. n Symmetrical ground conductors reduce induced voltage imbalances and carry common mode noise back to the drive. n High strand count design is much more flexible, easier to install and more resistant to vibration than Type MC cable. n Meets crush and impact requirements for Type MC cable. n AmerCable s specially formulated insulation material has a lower dielectric constant (standard XLPE and EPR insulation materials have higher dielectric constants) which withstands reflected voltages. This allows for longer output cable distances and minimizes the effect of high frequency noise induced into the plant ground system. n Permitted for Exposed Run ( ER ) use in accordance with the NEC. n Permitted for use in Class I, Division 2 and Zone 2 industrial hazardous locations per the NEC. n Gas and vapor tight impervious to water and air. n Reduced tray fill (up to 35% less) than Type MC. n Reduced installation time and cost compared to Type MC. n Glands for this product cost up to 50% LESS than those for Type MC. n Bend radius 12X O.D. 16 Manufactured by Nexans AmerCable (870) 862-4919 (800) 643-1516 Fax (870) 862-9613

37-108 VFD FLEXIBLE TC-ER VFD 600 VOLTS DC AC Grounding Resistance Resistance Inductive Voltage Drop Ampacity Size Size Part No. Diameter Weight at 25 C 90 C, 60Hz Reactance 90 C, 60Hz (x3) In Free In Cable In AWG/kcmil (mm2) 37-108 (inches) (lbs/1000ft) (ohms/1000ft) (ohms/1000ft) (ohms/1000ft) (Volts/Amp/1000ft) Size (AWG) Air Tray Conduit 14 2.08-508VFD 0.466 158 2.907 3.635 0.036 5.069 18 15 15 15 12 3.29-516VFD 0.509 199 1.826 2.283 0.034 3.195 16 20 20 20 10 5.23-308VFD 0.522 258 1.153 1.441 0.032 2.028 14 30 30 30 8 8.30-309VFD 0.653 368 0.708 0.885 0.036 1.262 14 65 55 48 6 13.21-310VFD 0.737 517 0.445 0.556 0.034 0.804 12 87 75 65 4 21.17-312VFD 0.956 814 0.300 0.376 0.031 0.552 12 114 95 89 2 35-314VFD 1.103 1178 0.184 0.230 0.030 0.349 10 152 130 119 1 42.52-315VFD 1.221 1462 0.147 0.184 0.031 0.287 10 177 150 137 1/0 50-316VFD 1.447 1714 0.117 0.147 0.030 0.235 10 205 170 163 2/0 66.12-317VFD 1.538 1951 0.093 0.117 0.029 0.193 10 237 195 186 4/0 95-319VFD 1.883 3102 0.058 0.075 0.028 0.133 8 316 260 253 262 120-320VFD 1.981 3642 0.048 0.063 0.026 0.114 6 362 297 286 313 150-321VFD 2.082 4185 0.040 0.053 0.026 0.100 6 404 328 324 373 185-322VFD 2.215 4834 0.034 0.045 0.025 0.088 6 449 364 357 444 240-323VFD 2.371 5634 0.028 0.039 0.025 0.079 6 497 402 396 535 272.68-324VFD 2.616 7592 0.024 0.033 0.025 0.071 6 556 446 441 646 300-326VFD 2.878 9183 0.020 0.028 0.025 0.065 4 617 496 489 777 400-327VFD 3.089 10834 0.016 0.025 0.025 0.060 4 688 546 537 Cable diameters are subject to a +/- 5% manufacturing tolerance Ampacity In Free Air: Based on 90 C conductor temperature and 30 C ambient temperature per 2008 NEC Table B.310.3 Ampacity In Cable Tray: Based on 90 C conductor temperature and 30 C ambient temperature per 2008 NEC Table 310.16 Ampacity In Conduit: Based on 90 C conductor temperature and 30 C ambient temperature per 2008 NEC Table B.310.1 Stranding Profile Size Size Number of Uninsulated AWG/kcmil (mm2) Strands Diameter (inch) 14 2.08 19 0.074 12 3.29 19 0.093 10 5.23 37 0.113 8 8.30 133 0.159 6 13.21 133 0.201 4 21.17 259 0.255 2 35 259 0.321 1 42.52 259 0.361 1/0 50 266 0.413 2/0 66.12 323 0.455 4/0 95 532 0.584 262 120 646 0.654 313 150 777 0.720 373 185 925 0.785 444 240 1110 0.860 535 272.68 1332 0.941 646 300 1591 1.029 777 400 1924 1.132 www.nexansamercable.com e-mail: industrial@nexansamercable.com 17

37-105VFD MMV-VFD POWER CABLE THREE CONDUCTOR: 8KV - 15KV 133% INSULATION LEVEL RATED 90 C s (3) Soft annealed flexible stranded tinned copper per IEEE 1580 Table 11. Extruded thermosetting 90 C Ethylene Propylene Rubber (EPR), meeting UL 1309 (Type E), IEEE 1580 (Type E) and UL 1072. Shield Composite shield consisting of 0.0126" tinned copper braided with nylon providing 60% copper Shielded coverage meeting UL 1309, IEEE Std. 1580, and UL 1072. The nylon is colored for easy phase identification (three conductor = black, blue, red) without the need to remove the shield to find an underlying colored tape. Low smoke halogen-free jacket available. Contact your AmerCable rep. Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072. Shield Semi-conducting layer meeting UL 1309, IEEE 1580 and UL 1072. Symmetrical Insulated Grounding s (3) Soft annealed flexible stranded tinned copper conductor per IEEE 1580 Table 11. Gexol sized per Table 23.2 of UL1072. Color: Green A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 1309/ CSA 245, IEEE 1580, and UL 1072. This jacket allows for isolation between the insulation shields and overall shield. Shields can then be terminated on opposite ends to minimize circulating currents. Armor/EMI Shield Overall tinned copper braid plus aluminum/ polyester tape provides 100% coverage. This braid serves as both an armor and EMI shield meeting both IEEE 1580 and UL 1307/CSA 245. Sheath (optional) A black, arctic grade, flame retardant, oil, abrasion, chemical and sunlight resistant thermosetting compound meeting UL 1309/CSA 245, IEEE 1580, and UL 1072. Colored jackets for signifying different voltage levels are also available on special request (orange = 8kV and red = 15kV). RATINGS & APPROVALS n UL Listed as Marine Shipboard Cable (E111461) n American Bureau of Shipping (ABS) n Det Norske Veritas (DNV) Pending n Lloyd s Register of Shipping (LRS) Pending n 90 C Temperature Rating n Voltage Rating 8kV to 15kV (25kV available on request) APPLICATIONS A flexible, braid and foil shielded, power cable specifically engineered for use in medium voltage variable frequency AC drive (VFD) applications. FEATURES n Flexible stranded conductors and braided shields. Suitable for applications involving repeated flexing and high vibration. n Small minimum bending radius (8x OD) for easy installation. n has a very low dielectric constant. This allows for longer output cable distances and minimizes common mode current. n Overall braid plus foil shield is engineered with 100% coverage and a surface transfer impedance <50 milliohms at 10MHz to contain EMI. n Symmetrical insulated ground conductors reduce induced voltage imbalances and carry common mode noise back to the drive. n High strand count conductors and braid shield design is much more flexible, easier to install and more resistant to vibration than Type MC cable. n Severe cold durability: exceeds CSA cold bend/cold impact (-40 C/-35 C). n Flame retardant: IEC 332-3 Category A and IEEE 1202. n Suitable for use in Class I, Division 1, and Zone 1 environments. 18 Manufactured by Nexans AmerCable (870) 862-4919 (800) 643-1516 Fax (870) 862-9613

THREE CONDUCTOR TYPE MMV-VFD MEDIUM VOLTAGE 8KV 133% INSULATION LEVEL Single Inductive Voltage Green Insulated Size Weight In Free Banked DC Resistance AC Resistance Reactance Drop Grounding AWG/ Part No. Diameter (Lbs./ Air in Trays at 25 C at 90 C, 60Hz (ohms/ (Volts per amp (3x) kcmil mm2 37-105 (inches) 1000 Ft.) (amps) (amps) (ohms/1000 Ft.) (ohms/1000 Ft.) 1000 Ft.) per 1000 Ft.) Size (AWG) 6 4 2 1 1/0 2/0 3/0 4/0 262 313 373 444 535 12.5 21 34 43 54 70 86 109 132 159 189 227 273-332TSVFD -333TSVFD -334TSVFD -335TSVFD -336TSVFD -337TSVFD -338TSVFD -339TSVFD -340TSVFD -341TSVFD -342TSVFD -343TSVFD -344TSVFD 1.687 1.868 2.071 2.161 2.262 2.381 2.489 2.631 3.857 3.030 3.164 3.319 3.492 1634 2074 2625 3022 3373 3826 4411 5093 5993 6867 7810 8855 9905 Ampacity 88 116 152 175 201 232 266 306 348 386 429 455 528 75 99 129 149 171 197 226 260 296 328 365 387 449 0.445 0.300 0.184 0.147 0.117 0.093 0.074 0.058 0.048 0.040 0.034 0.028 0.024 Cable diameters are subject to a +/- 5% manufacturing tolerance 0.556 0.376 0.230 0.184 0.147 0.117 0.094 0.075 0.063 0.053 0.045 0.039 0.033 0.048 0.043 0.040 0.038 0.037 0.036 0.035 0.033 0.032 0.032 0.031 0.030 0.030 0.820 0.564 0.359 0.294 0.242 0.199 0.166 0.139 0.121 0.106 0.094 0.085 0.076 10 10 10 8 8 8 6 6 6 6 4 4 4 THREE CONDUCTOR TYPE MMV-VFD MEDIUM VOLTAGE 15KV 133% INSULATION LEVEL Ampacity Single Inductive Voltage Green Insulated Size Weight In Free Banked DC Resistance AC Resistance Reactance Drop Grounding AWG/ Part No. Diameter (Lbs./ Air in Trays at 25 C at 90 C, 60Hz (ohms/ (Volts per amp (3x) kcmil mm2 37-105 (inches) 1000 Ft.) (amps) (amps) (ohms/1000 Ft.) (ohms/1000 Ft.) 1000 Ft.) per 1000 Ft.) Size (AWG) 2 1 1/0 2/0 3/0 4/0 262 313 373 444 34 43 54 70 86 109 132 159 189 227-357TSVFD -358TSVFD -359TSVFD -360TSVFD -361TSVFD -362TSVFD -363TSVFD -364TSVFD -365TSVFD -366TSVFD 2.403 2.468 2.596 2.714 2.875 3.028 3.260 3.363 3.500 3.652 3231 2959 4090 4615 5306 6131 7074 7787 8703 9912 156 178 205 234 269 309 352 389 432 456 133 151 174 199 229 263 299 331 367 388 0.184 0.147 0.117 0.093 0.074 0.058 0.048 0.040 0.034 0.028 0.230 0.184 0.147 0.117 0.094 0.075 0.063 0.053 0.045 0.039 0.0440. 0430.041 0.0390.038 0.037 0.035 0.034 0.034 0.033 0.364 0.299 0.246 0.203 0.170 0.142 0.124 0.109 0.097 0.080 10 8 8 8 6 6 6 6 4 4 Cable diameters are subject to a +/- 5% manufacturing tolerance Ampacity in Free Air: Based on 105 C conductor temperature and 40 C ambient temperature per 2008 NEC Table 310.71 Ampacity in Conduit Air: Based on 105 C conductor temperature and 40 C ambient temperature per 2008 NEC Table 310.75 www.nexansamercable.com e-mail: industrial@nexansamercable.com 19

37-449-5020PNAV ENHANCED THOF SHIP-TO-SHORE POWER CABLE 90 C 600 VOLTS FLEXIBLE Type I EPR rated for 90 C in wet or dry locations. Meets requirements of UL 44 RHH, RHW-2 Color coded white red black Reinforced, flame retardant extra heavy duty black thermoset CPE specially formulated to resist the abrasive nature of the application s 500 kcmil tin coated copper. ASTM B-33, ASTM B-172 Separator 2 mil non-hygroscopic opaque polyester APPLICATION A flexible 600V cable used for ship-toshore power. Replaces former MIL-C 915 design for most applications. FEATURES n Complies with OPNAVINST 11310.3B n Integral filled inner jacket for enhanced toughness and crush resistance n Water migration minimized n Mold cured reinforced jacket for enhanced abrasion and tear resistance n Pigment colored jacketed singles for phase identification n Tinned copper conductors for reduced corrosion n Indent printed for long term identification n Functional testing to ensure flexibility in both summer and winter conditions RATINGS & APPROVALS n ICEA S 75-381: Portable and Power Feeder Cables for Use in Mines and Similar Applications Product Part No. Size AWG/ kcmil Outside Diameter Approx. Weight lbs. per 1,000 ft. Enhanced THOF 37-449-502OPNAV 500 2.875 7563 Cable diameters and weights are subject to +/- 5% manufacturing tolerance Consult factory for availability of other conductor sizes MIL-C 915 cable is also available. Consult factory for details. 20 Manufactured by Nexans AmerCable (870) 862-4919 (800) 643-1516 Fax (870) 862-9613

37-449-5030PNAV ENHANCED PLUS THOF SHIP-TO-SHORE POWER CABLE 90 C 600 VOLTS FLEXIBLE EPR per ICEA S-75-381 Meets requirements of UL 44 RHH, RHW-2 Enhanced Plus Only. CPE Composite meets requirements of UL 44 RHH, RHW-2. Pigment colored red, white and black. Class I, 500 kcmil tin coated copper. ASTM B-33, ASTM B-172 Extra-Heavy duty reinforced, flame retardant black thermoset CPE per ICEA S-75-381. Specially formulated to resist the abrasive nature of the application. APPLICATION A tough flexible 3/C 600V ungrounded power cable specifically designed for naval shore-to-ship and other pier side power applications. Enhanced Plus THOF is specially designed for additional sunlight and weather resistance. FEATURES n Complies with OPNAVINST 11310.3B n Integral filled inner jacket for enhanced toughness and crush resistance n Water migration minimized n Mold cured reinforced jacket for enhanced abrasion and tear resistance n ed singles (Enhanced Plus) for increased resistance to sunlight and weather n Pigment colored jacketed singles for phase identification n Tinned copper conductors for reduced corrosion n Indent printed for long term identification n Functional testing to ensure flexibility in both summer and winter conditions RATINGS & APPROVALS n ICEA S-75-381: Portable and Power Feeder Cables for Use in Mines and Similar Applications Product Part No. Size AWG/ kcmil Outside Diameter Approx. Weight lbs. per 1,000 ft. Enhanced Plus THOF 37-449-503OPNAV 500 3.003 7854 Cable diameters and weights are subject to +/- 5% manufacturing tolerance Consult factory for availability of other conductor sizes MIL-C 915 cable is also available. Consult factory for details. www.nexansamercable.com e-mail: industrial@nexansamercable.com 21

37-003 FLEXIBLE GROUNDING CABLE CLEAR YELLOW OTHER COLORS Transparent thermoplastic for ease of installation and flexible use at temperatures ranging from -25 C to 90 C. This material meets Type II requirements of ASTM F 855. Material meeting a -50 C cold bend is available on a special order basis. Bunched strands of bare copper annealed dead soft in accordance with ASTM B-3. Other strand is available upon request. Identification A marker tape printed AMERCABLE-SIZE- GROUNDING CABLE is readily visible under the transparent jacket. APPLICATION Flexible jacketed cable used for grounding jumpers installed temporarily for protective grounding of de-energized circuits. FEATURES n Transparent jacket provides easy confirmation of continuity and ease of trouble shooting n Extremely flexible stranding for ease of bending and installation n Transparent thermoplastic jacket for installation and flexible use at temperatures ranging from -25 C to 90 C n material meets Type II requirements of ASTM F-855 n material meeting Type I (-50 C) requirements of ASTM F-855 available upon request Part No. 37-003- Size AWG/ kcmil Minimum Wires per 002 2 665 0.100 0.530 293 010 1/0 1050 0.100 0.650 458 020 2/0 1323 0.105 0.700 557 040 4/0 2107 0.110 0.850 857 Cable diameters and weights are subject to +/- 5% manufacturing tolerance Outside Diameter Other ground jacketing materials and colors available. Consult factory for details. Approx. Weight lbs. per 1,000 ft. RATINGS & APPROVALS n ASTM B-3: Standard Specification for Soft or Annealed Copper Wire n ASTM F-855: Standard Specifications for Temporary Protective Grounds to Be Used on De-energized Electric Power Lines and Equipment Order Your Grounding Cables with Factory Installed Connectors SAVE TIME SAVE MONEY 22 Manufactured by Nexans AmerCable (870) 862-4919 (800) 643-1516 Fax (870) 862-9613

37-409 LEAD COVERED GROUNDING CABLE Uncoated annealed copper meeting the requirements of ASTM B-3 APPLICATION A grounding conductor for use in power distribution systems where a lead sheath is required over the copper conductor to provide additional protection against corrosion. Also suitable for use in lightening protection applications. FEATURES n Lead sheath offers rugged, durable construction RATINGS & APPROVALS n ASTM B-3: Standard Specification for Soft or Annealed Copper Wire Lead Sheath An extruded layer of lead for enhanced performance n ASTM B-8: Standard Specification for Concentric-Lay-Stranded Copper s, Hard, Medium-Hard or Soft Part No. 37-409- Size AWG/ kcmil Minimum Wires per Lead Sheath Outside Diameter Approx. Weight lbs. per 1,000 ft. 004 4 7 0.045 0.319 366 005 2 7 0.045 0.377 508 366 1/0 19 0.065 0.497 836 020 2/0 19 0.065 0.542 984 360 3/0 19 0.065 0.600 1202 615 4/0 19 0.065 0.648 1420 250 250 37 0.065 0.694 1528 351 350 37 0.065 0.797 1985 147 400 37 0.065 0.842 2478 361 500 37 0.065 0.931 2684 Cable diameters and weights are subject to +/- 5% manufacturing tolerance www.nexansamercable.com e-mail: industrial@nexansamercable.com 23

37-221 RED JUMPER CABLE FLEXIBLE 5000/15000 VOLTS 90 C s Flexible-stranded, tinned, annealed coated copper per ASTM B-33 Shield Combination semiconducting tape and/or extruded semiconductive thermosetting material. The semiconductive tape prevents any penetration of the extruded conductor shield into the inner layers of the flexible conductor. Thermosetting bright red jacket, 90 C rated RATINGS & APPROVALS Heat resisting 90 C Ethylene-Propylene rubber (EPR), meeting ASTM D-2802. It has excellent dielectric properties and is highly resistant to heat, moisture, and ozone. Identification Cable is surface printed showing manufacturer s name, size, voltage rating, and temperature rating APPLICATION Portable dual rated 5000/15000 volt jumper cables can be used as temporary jumper leads for portable or mobile substations, or for temporarily by-passing damaged or faulted sections of power cable. The finely stranded conductor provides an exceptionally flexible cable that can be easily trained and connected in confined areas such as transformer vaults and switch gear enclosures. Features n Extremely flexible stranding n Bright red thermosetting jacket n The conductor shield is bonded to the insulation providing easy, clean stripping n The 90 C insulation has excellent dielectric properties and is highly resistant to heat, moisture and ozone. n ASTM B-33: Standard Specification for Tinned Soft or Annealed Copper Wire for Electrical Purposes n ASTM D2802: Standard Specification for Ozone- Resistant Ethylene-Alkene Polymer for Wire and Cable APPLICATION NOTE Jumper cables should NOT be used in place of normal high voltage cables. They should be isolated in areas where contact with people is limited. Because jumper cables cannot be protected against prolonged contact with other conductors or grounds by shielding, these cables must be positioned away from contact with grounds, transformer cases, cross-arms, etc., to avoid possible high stress and capacitance leakage. Cables should be installed with at least one cable diameter of separation between adjacent conductors and between conductors and all metallic and/or electrically grounded parts. These cables are not intended for permanent service. 24 Manufactured by Nexans AmerCable (870) 862-4919 (800) 643-1516 Fax (870) 862-9613

37-221 RED JUMPER CABLE 5000/15000 VOLTS Part No. 37-221- Size AWG/ kcmil Minimum Wires per Outside Diameter 008 8 133 0.210 0.065 0.777 310 83/NA* 006 6 133 0.210 0.065 0.816 360 110/110 004 4 259 0.210 0.065 0.875 449 145/150 003 3 259 0.210 0.065 0.903 495 170/170 002 2 259 0.210 0.065 0.944 563 190/195 001 1 259 0.210 0.065 0.981 635 225/225 010 1/0 266 0.210 0.065 1.040 742 260/260 020 2/0 323 0.210 0.065 1.090 869 300/300 030 3/0 418 0.210 0.065 1.133 976 345/345 040 4/0 532 0.210 0.065 1.215 1181 400/400 250 250 627 0.210 0.065 1.216 1281 445/445 350 350 888 0.210 0.065 1.327 1692 550/550 500 500 1221 0.210 0.065 1.456 2192 695/685 8 AWG Jumper recommended only for use at 5kv Cable diameters and weights are subject to +/- 5% manufacturing tolerance Ampacity is calculated with a 90 C conductor temperature and 40 C ambient air, per 2008 NEC, Table 310.69 Approx. Weight Ampacity lbs. per 90 C 1,000 ft. at 5kV/15 kv Order Your Red Jumper Cable with Factory Installed Connectors SAVE TIME SAVE MONEY www.nexansamercable.com e-mail: industrial@nexansamercable.com 25

37-550 MOBILE SUBSTATION POWER CABLE TYPE SH SINGLE CONDUCTOR 5000 TO 35000 VOLTS 90 C Flexible tin-coated soft annealed bunch stranded copper meeting ASTM B-33 Shield Tin-coated copper braid applied over a semiconductive tape (5-15kV). Extruded semi-conductive thermosetting material (25-35kV) CPE meeting ICEA S-75-381/NEMA WC58. Consult factory for availability of other jacket materials. Shield Combination semi-conducting tape and/or extruded semiconductive thermosetting material Heat, moisture and ozone resisting 90 C Ethylene- Propylene rubber (EPR) meeting ICEA S-75-381/NEMA WC58 Identification Cable shall be surface printed showing manufacturer, size, voltage rating, type and temperature rating APPLICATION These single conductor portable power cables are extremely flexible and specifically designed for use on mobile substation equipment. The Type SH cable is often necessary for supplying power while replacing damaged utility poles or during routine maintenance of substations. FEATURES n Extremely flexible stranding for ease of bending n The conductor shield is bonded to the insulation providing easy, clean stripping n is heat, oil, flame and chemical resistant n Continuous conductor temperature 90 C n s available in voltage colors, yellow (5 & 8kV), orange (15kV), red (25 & 35kV). Consult factory for availability of other colors. RATINGS & APPROVALS n ASTM B-33: Standard Specification for Tinned Soft or Annealed Copper Wire for Electrical Purposes n ICEA S-75-381/NEMA WC- 58: Portable and Power Feeder Cables for Use in Mines and Similar Applications n UL 1072 Medium Voltage Cable MV-105 (pending) CSA approval available by special order 26 Manufactured by Nexans AmerCable (870) 862-4919 (800) 643-1516 Fax (870) 862-9613

5KV SINGLE CONDUCTOR PORTABLE POWER CABLE TYPE SH Part No. 37-550- Size AWG/ kcmil Minimum Wires per Outside Diameter Approx. Weight lbs. per 1,000 ft. Ampacity 90 C 002 2 259.110.125 0.975 674 190 004 1/0 266.110.140 1.058 825 260 005 2/0 323.110.140 1.170 1039 300 007 4/0 532.110.155 1.300 1393 400 008 250 627.120.155 1.330 1477 445 022 350 888.120.170 1.484 1926 550 010 500 1221.120.190 1.700 2662 695 15KV SINGLE CONDUCTOR PORTABLE POWER CABLE TYPE SH Part No. 37-550- Size AWG/ kcmil Minimum Wires per Outside Diameter Approx. Weight lbs. per 1,000 ft. Ampacity 90 C 016 2 259.210.155 1.203 881 195 017 1/0 266.210.155 1.320 1147 260 018 2/0 323.210.155 1.350 1226 300 020 4/0 532.210.170 1.497 1594 400 021 250 627.210.170 1.547 1758 445 009 350 888.210.190 1.765 2364 550 024 500 1221.210.190 1.900 2937 685 25KV SINGLE CONDUCTOR PORTABLE POWER CABLE TYPE SH Part No. 37-550- Size AWG/ kcmil Minimum Wires per Outside Diameter Approx. Weight lbs. per 1,000 ft. Ampacity 90 C 030 1/0 266.295.170 1.500 1350 260 031 2/0 323.295.170 1.555 1507 300 033 4/0 532.295.190 1.713 1909 395 034 250 627.295.190 1.763 2085 440 035 350 888.295.190 1.886 2517 545 037 500 1221.295.205 2.048 3168 680 Order Your Type SH Cables Connectorized! Factory installed assemblies from AmerCable help lower your overall connectivity costs. n Lugs n Elbows n Stress Cones 35KV SINGLE CONDUCTOR PORTABLE POWER CABLE TYPE SH Part No. 37-550- Size AWG/ kcmil Minimum Wires per Outside Diameter Approx. Weight lbs. per 1,000 ft. 050 1/0 266.380.170 1.175 1632 260 051 2/0 342.380.205 1.840 1898 300 053 4/0 532.380.205 1.915 2235 395 054 250 627.380.205 1.975 2509 440 055 350 888.380.205 2.100 2901 545 057 500 1221.380.205 2.280 3396 680 Cable diameters and weights are subject to +/- 5% manufacturing tolerance Ampacity is calculated with a 90 C conductor temperature and 40 C ambient air, per 2008 NEC, Table 310.69 Ampacity 90 C www.nexansamercable.com e-mail: industrial@nexansamercable.com 27

FACTORY INSTALLED CABLE ASSEMBLIES Factory Installed Cable Assemblies from Nexans AmerCable are professionally assembled in our El Dorado, Arkansas manufacturing facility. Our team of experienced handlers join cables and connectors that match your exact application spec. Our assemblies are designed, built and tested to perform upon arrival in your harshest operating conditions. Factory prepared cable assemblies are a reliable way to lower your overall cable connectivity costs through enhanced reliability, reduced handling and lower installation time. n Lugs n Elbows n Stress Cones Save money through reduced prep, handling and installation time. 28 Manufactured by Nexans AmerCable (870) 862-4919 (800) 643-1516 Fax (870) 862-9613

RENEWABLE ENERGY CABLES Nexans AmerCable is the leading producer of renewable energy cables in North America. Contact your Nexans AmerCable rep for a copy of our Renewable Energy Cables catalog. Wind Applications email: greencables@nexansamercable.com Phone: 800-506-9473 713-896-5800 Solar Applications email: solarcables@nexansamercable.com Phone: 800-643-1516 870-862-4919 Wind Power Cables Type MMV-WP 1/C and 3/C 5kV, 15kV and 35kV Rated 105 C Medium Voltage Wind Turbine Service Loops DLO 2000 Volts 90 C Low Smoke (sizes 2/0 & higher) EP/CPE RHH, RHW-2 Solar Power Cables Nexans AmerCable s AmerSol is the first U.S. manufactured solar cable to achieve TÜV and UL certification. This versatile single-conductor cable is designed to meet the varying needs of the Solar Industry. Applications include connection to module junction boxes; required cable routing in balance of system (BOS) integration. Rated 600V UL and 1000V TÜV. Also available: Type PV UL4703 (2000V) and Type TC Multiconducutor (2000V) www.nexansamercable.com e-mail: industrial@nexansamercable.com 29

INDUSTRIAL CABLES DESIGNED FOR LONGER SERVICE LIFE IN HARSH ENVIRONMENTS For complete product information: www.nexansamercable.com Nexans AmerCable manufactures high quality jacketed electrical cables for a wide variety of specialized industrial and utility applications. Nexans AmerCable is an ISO 9001 certified cable manufacturer that combines leading-edge technology, proven manufacturing techniques, and high quality service to deliver the finest industrial and utility cable products available. Nexans AmerCable serves a worldwide customer base from our manufacturing facility in El Dorado, Arkansas. Our professional field engineering and sales force work directly with customers, or in partnership with our network of independent distributors, to identify and fulfill your specific cable requirements CLICK HERE TO FOLLOW US! Manufacturing facility and corporate headquarters - El Dorado, Arkansas. Nexans AmerCable 350 Bailey Road - El Dorado, AR USA 800-643-1516 870-862-4919 Fax: 870-862-9613 email: industrial@nexansamercable.com www.nexansamercable.com 2017, AmerCable Incorporated 10_17 Made in America