TCSPC at Wavelengths from 900 nm to 1700 nm

Similar documents
IR Antibunching Measurements with id201 InGaAs Gated SPAD Detectors

PZ-FLIM-110. Piezo Scanning FLIM System. Based on bh s Megapixel FLIM Technology. Complete FLIM Microscopes FLIM Upgrades for Existing Microscopes

Wide-Field TCSPC FLIM with bh SPC-150 N TCSPC System and Photek FGN Detector

An 8-Channel Parallel Multispectral TCSPC FLIM System

DCS-120. Confocal Scanning FLIM Systems. Based on bh s Multidimensional Megapixel FLIM Technology

DCS-120. Confocal Scanning FLIM Systems. Based on bh s Multidimensional Megapixel FLIM Technology

Non-Descanned FLIM Detection in Multiphoton Microscopes

Megapixel FLIM with bh TCSPC Modules

Instrument response function. Left linear scale, right logarithmic scale. FWHM is 120 ps.

The DCS-120 Confocal Scanning FLIM System

BDS-SM Family Picosecond Diode Lasers

BDS-SM Family Picosecond Diode Lasers

Multiphoton FLIM with the Leica HyD RLD Detectors

Picosecond Light Sources

TCSPC measurements with the InGaAs/InP Single- photon counter

BDS-MM Family Picosecond Diode Lasers

PCS-150 / PCI-200 High Speed Boxcar Modules

NUV and Blue ps Diode Lasers

Becker & Hickl GmbH. Technology Leader in Photon Counting

Boston Electronics Corporation 91 Boylston Street, Brookline MA USA (800) or (617) fax (617)

Redefining Measurement ID101 OEM Visible Photon Counter

Ultraviolet and Blue Picosecond Diode Laser Modules

Time-Correlated Single Photon Counting Systems

Time-Correlated Single Photon Counting

Boston Electronics Corporation 91 Boylston Street, Brookline MA USA (800) or (617) fax (617)

Photon Count. for Brainies.

High Performance Photon Counting. User Manual PML-16-C. 16 Channel Detector Head for Time-Correlated Single Photon Counting. Becker & Hickl GmbH

InGaAs SPAD BIOMEDICAL APPLICATION INDUSTRIAL APPLICATION ASTRONOMY APPLICATION QUANTUM APPLICATION

Time Correlated Single Photon Counting Systems

User Handbook. DPC Channel Photon Correlator

Multi-wavelength TCSPC lifetime imaging Wolfgang Becker a, Axel Bergmann a, Christoph Biskup b, Thomas Zimmer b, Nikolaj Klöcker c, Klaus Benndorf b

SHM-180 Eight Channel Sample & Hold Module

TCSPC for FLIM and FRET in Microscopy

InGaAs SPAD freerunning

FLIM Protocol. 1. Install IRF sample on the microscope using the stage insert. IRF sample options include urea crystals or BBO crystal.

PML Channel Detector Head for Time-Correlated Single Photon Counting

A New Single-Photon Avalanche Diode in 90nm Standard CMOS Technology

Solea. Supercontinuum Laser. Applications

DeltaMyc. Fluorescence Lifetime Mapping Microscope. Affordable Fluorescence Lifetime Imaging Microscopy (FLIM)

3D light microscopy techniques

Supplemental Information

WHITE PAPER FAST PROTEIN INTERACTION BINDING CURVES WITH INO S F-HS CONFOCAL MICROSCOPE

Direct Measurement of Optical Cross-talk in Silicon Photomultipliers Using Light Emission Microscopy

Becker & Hickl GmbH DCS-120. Confocal Scanning FLIM Systems. An Overview

LABORATÓRIUMI GYAKORLAT SILLABUSZ SYLLABUS OF A PRACTICAL DEMONSTRATION. financed by the program

Direct Measurement of Optical Cross-talk in Silicon Photomultipliers Using Light Emission Microscopy

Simultaneous Phosphorescence and Fluorescence Lifetime Imaging by Multi-Dimensional TCSPC and Multi-Pulse Excitation

Why and How? Daniel Gitler Dept. of Physiology Ben-Gurion University of the Negev. Microscopy course, Michmoret Dec 2005

Supplementary Figure S1: Schematic view of the confocal laser scanning STED microscope used for STED-RICS. For a detailed description of our

Point Spread Function. Confocal Laser Scanning Microscopy. Confocal Aperture. Optical aberrations. Alternative Scanning Microscopy

TRAINING MANUAL. Multiphoton Microscopy LSM 510 META-NLO

MEGAFRAME: a fully integrated, timeresolved SPAD pixel array with microconcentrators

Imaging Retreat - UMASS Customized real-time confocal and 2-photon imaging

Characteristics of point-focus Simultaneous Spatial and temporal Focusing (SSTF) as a two-photon excited fluorescence microscopy

Silicon Photomultiplier

Practical work no. 3: Confocal Live Cell Microscopy

Confocal Imaging Through Scattering Media with a Volume Holographic Filter

BASICS OF CONFOCAL IMAGING (PART I)

Detectors for High-Speed Photon Counting

Characterizing a single photon detector

combustion diagnostics

SINPHOS SINGLE PHOTON SPECTROMETER FOR BIOMEDICAL APPLICATION

APE Autocorrelator Product Family

Maria Smedh, Centre for Cellular Imaging. Maria Smedh, Centre for Cellular Imaging

ADVANTAGES OF SILICON PHOTON COUNTERS IN GATED MODE APPLICATION NOTE

Reflecting optical system to increase signal intensity. in confocal microscopy

FluoTime 300 for Time-Resolved and Steady-State Spectroscopy

Wavelength LDH - P / D - _ / C / F / FA / TA - N - XXX - _ / B / M / L / XL. Narrow linewidth (on request) Tappered amplified

Bandpass Edge Dichroic Notch & More

Akinori Mitani and Geoff Weiner BGGN 266 Spring 2013 Non-linear optics final report. Introduction and Background

Single-photon excitation of morphology dependent resonance

3D light microscopy techniques

High Power Supercontinuum Fiber Laser Series. Visible Power [W]

Basics of confocal imaging (part I)

Instruction manual and data sheet ipca h

Advantages of gated silicon single photon detectors

BIOIMAGING AND OPTICS PLATFORM EPFL SV PTBIOP LASER SCANNING CONFOCAL MICROSCOPY PRACTICAL CONSIDERATIONS

680nm Quasi Single-Mode VCSEL Part number code: 680Q-0000-X002

Rates of excitation, emission, ISC

W32 ID Quantique: Entanglion Game and Quantum Optics Demo room DS 141

pulsecheck The Modular Autocorrelator

Imaging Beyond the Basics: Optimizing Settings on the Leica SP8 Confocal

Operation Guide for the Leica SP2 Confocal Microscope Bio-Imaging Facility Hunter College October 2009

Nano-structured superconducting single-photon detector

1 Co Localization and Working flow with the lsm700

D2.1 Operating 2D STED Microscope

Things to check before start-up.

PoS(PhotoDet 2012)058

PERFORMANCE OF PHOTODIGM S DBR SEMICONDUCTOR LASERS FOR PICOSECOND AND NANOSECOND PULSING APPLICATIONS

Resolution. Diffraction from apertures limits resolution. Rayleigh criterion θ Rayleigh = 1.22 λ/d 1 peak at 2 nd minimum. θ f D

Lab4 Hanbury Brown and Twiss Setup. Photon Antibunching

PGS Family Plane Grating Spectrometer from ZEISS

Metrology for QKD an industrial quantum optical communication technology

Simple setup for nano-second time-resolved spectroscopic measurements by a digital storage oscilloscope

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

IPD3. Imaging Photon Detector APPLICATIONS KEY ATTRIBUTES

Single-Photon Counting Detectors for the Visible Range Between 300 and 1,000 nm

CHAPTER 11 HPD (Hybrid Photo-Detector)

Examination, TEN1, in courses SK2500/SK2501, Physics of Biomedical Microscopy,

Applications of Steady-state Multichannel Spectroscopy in the Visible and NIR Spectral Region

Transcription:

TCSPC at Wavelengths from 900 nm to 1700 nm We describe picosecond time-resolved optical signal recording in the spectral range from 900 nm to 1700 nm. The system consists of an id Quantique id220 InGaAs SPAD, a bh SPC-150 TCSPC device, and a bh BDS-SM 1064 nm ps diode laser. In contrast to earlier InGaAs SPADs the id220 works in a continuous (asynchronous) mode. The id 220 / SPC-150 combination can be operated at a pulse repetition rate in the 10 to 100 MHz range. As a result, there is virtually no pile-up distortion, and advanced multi-dimensional TCSPC modes are applicable. The width of the temporal IRF (Instrument Response Function) is about 230 ps, including laser pulse width and pulse dispersion in the optics. We demonstrate the application of the system to the recording of time-of-flight distributions in turbid media, for fluorescence decay measurement, and for fluorescence lifetime imaging (FLIM) in combination with fast galvanometer scanning. Detectors for the Spectral Range beyond 900 nm For many years, a problem of TCSPC was the lack of suitable single-photon detectors for the infrared region. PMTs with IR-sensitive cathodes were available but suffered from high dark count rate and low quantum efficiency. Superconducting detectors have good quantum efficiency but extremely small active areas. They are still in the state of prototype development. The situation improved with the availability of single-photon avalanche diodes (SPADs) based on InGaAs material. These detectors achieve a quantum efficiency of about 20% at a wavelength 1300 nm. The useful wavelength range extends from 900 nm to 1700 nm. The problem of early InGaAs SPADs was the high dark count rate, and the strong afterpulsing. To avoid instability, the devices could only be operated in a gated mode: The reverse voltage was increased above the breakdown level for a period of 10 to a few 100 ns, and then decreased below the critical level for several microseconds. Gated operation is acceptable for general photon counting in combination with low-repetition rate light sources. It is, however, a problem in combination with TCSPC: TCSPC works best at high repetition rate of the light signals, and requires the detector to be active continuously. Standard TCSPC detection in the IR became possible with the introduction of the Id Quantique id220 detector [1]. The id220 is the first InGaAs SPAD that is operated in a continuous mode. It thus can be used for TCSPC without any restrictions. In this article, we demonstrate IR TCSPC by combining an id220 detector [1], a bh Simple-Tau 150 system [3], and a BDS-SM (1064 nm) picosecond diode laser [4]. The components are shown in Fig. 1. Fig. 1: Left to right: Id 220 InGaAs SPAD detector, Simple-Tau 150 TCSPC system, BDS-SM picosecond diode laser id-220-tcspc-04 April 2013 1

TCSPC at Wavelengths from 900 nm to 1700 nm Basic TCSPC Experiment For a general test of the id220 in combination with the bh TCSPC modules we used the setup shown in Fig. 2. A bh BDS-SM picosecond diode laser generates a 50 MHz train of picosecond light pulses at a wavelength of 1064 nm. The optical output from the laser is via a single-mode fibre. The end of the fibre was brought in contact with a cuvette containing a dye solution or a scattering medium. The light from the sample was collected by a multi-mode fibre and transferred to the detector. The TCSPC system was a bh Simple-Tau 150, containing an SPC-150 TCSPC module [3]. The detector output pulses were adapted to the input voltage range of the SPC module by an attenuator and an A-PPI-D pulse inverter. The synchronisation of the TCSPC module comes directly from the laser. BDS-SM Laser 1064 nm Cuvette Single-mode Filter Multi-mode Id 200 InGaAs SPAD detector 12 db A-PPI-D Attenuator from Laser Pulse Inverter SYNC CFD Fig. 2: Standard TCSPC experiment Compared to a setup with focusing and light-collecting lenses the optics is not the most efficient one. It was used because it is insensitive to alignment and thus less likely to produce artefacts by reabsorption and re-emission. Typical waveforms recorded with the system are shown in Fig. 3. The curves show signals obtained from diluted milk (black curve), IR1061 (Aldrich, brown curve), and undiluted milk (red curve). Fig. 3: Waveforms recorded with the setup shown in Fig. 2. Black curve : Diluted Milk. The curve can be expected to reproduce the temporal IRF. Brown curve: Fluorescence decay of IR1061. Red curve: Photon migration in milk, undiluted. Time axis 0 to 5 ns, 500 ps per division, 1.22 ps per data point. The curve from the diluted milk (black curve) can be expected to reproduce the temporal IRF. It is surprisingly fast: The full width at half maximum (FWHM) is 230 ps. This includes the laser pulse width, the transit time differences in the 1 cm cuvette, and the transit time spread in the detector fibre. A deconvolution of the IR1061 fluorophore from the IRF delivers about 50 ps. This is in 2 id-220-tcspc-04 April 2013

agreement with the fluorescence decay time reported for IR1061 in the literature. The photon migration time (shift of first moment) in the milk is about 85 ps. This appears low compared to measurements at wavelengths below 800 nm but can be explained by the fact that the scattering coefficient decreases with the wavelength. Operating Conditions of the Detector The id 220 detector comes with software that allows the user to adapt the detector parameters to the current experiment. Both the detection efficiency and the dead time (quenching time after detecting a photon) can be modified. We made test measurement with various parameter combinations. The best TCSPC results were obtained with the detection efficiency set to the maximum of 20%, and a dead time of 5 µs. Reducing the detection efficiency results in lower dark count rate. However, the efficiency drops by the same ratio as the dark count rate. Unless there is abundance of light little is gained in terms of signal-to noise ratio. Moreover, lower detection efficiency results in a broader IRF. Reducing the detection efficiency is therefore not recommended. The dead time of 5 µs was found to be a compromise between counting speed and afterpulsing background. Dead time settings larger than 5 µs unnecessarily reduce the saturated count rate, dead times shorter than 5 µs result in a noticeable increase of the signal-dependent counting background. Please note that a dead time of 5 µs is much longer than the dead time of the bh TCSPC modules, and much longer than the dead time of visible-range detectors. For 5 µs dead time, the saturated count rate is 200 khz. The recording rate should therefore be kept below 100 khz. Fluorescence Lifetime Imaging (FLIM) Fig. 4: Setup of the id 200 detector parameters We evaluated the performance of the id 220 / SPC-150 combination for TCSPC FLIM at infrared wavelengths. TCSPC FLIM uses the capability of multi-dimensional TCSPC to record a photon distribution over several parameters [2]. The sample is scanned by a focused laser beam. Single photons of the fluorescence light are detected, and, for every individual photon, the time in the laser pulse period and the location of the laser spot in the image area are determined. Accumulating the photons over a large number of scans, the TCSPC device builds up a photon distribution over the time in the signal period and the coordinates of the scan. The result can be considered an array of pixels, each one containing a full fluorescence decay curve. The advantage of the multi-dimensional recording id-220-tcspc-04 April 2013 3

TCSPC at Wavelengths from 900 nm to 1700 nm process is that it does not reject any photons by gating, and that it works at the high scan rates used in modern lasers scanning microscopes. The experimental setup is shown in Fig. 5. It consists of a Simple-Tau TCSPC system, a BDS-SM 1064 nm picosecond diode laser, a bh DCS-120 confocal scan head [3, 5] attached to a Nikon TE 2000 microscope, and the id220 InGaAS SPAD detector. Simple-Tau 150 TCSPC System TRG Out BDS-SM, 1064nm Picosecond diode laser Single-Mode Collimator Microscope SYNC CFD Id 220 InGaAs SPAD Detector Multi-Mode Filter Main dichroic beamsplitter Galvamometer mirrors Scan lens Scanner control Fig. 5: Principle of FLIM setup DCS-120 Scan Head, modified for fibre output (simplified ) A typical IR FLIM image obtained with the system is shown in Fig. 6. The image shows cellulose fibres stained with IR 1061 from Aldrich. The image format is 512 x 512 pixels, 256 time channels per pixel. An x20, NA=0.6 microscope lens was used. The detector count rate was kept below 50 KHz to avoid saturation of the intensity data. The excitation power for this count rate was about 30 µw in the sample plane. Fig. 6: Cellulose fibres, stained with IR1061 (Aldrich). Excitation 1064 nm, detection 1100nm to 1400nm. 512x512 pixels, 256 time channels per pixel. Colour represents fluorescence lifetime, lifetime range from 0 to 80 ps. 4 id-220-tcspc-04 April 2013

The FLIM data were processed by bh s SPCImage FLIM analysis software [5, 6]. The analysis was performed with a measured IRF, obtained from the reflection of the laser at the cover slip. The IRF and a typical decay curve from a selected pixel are shown in Fig. 7. As expected from the results of the cuvette experiments, the fluorescence lifetimes are very short. The distribution of the lifetime over the pixels peaks at about 50 ps. Despite of the fact that the lifetimes are much shorter than the FWHM of the detector, clear lifetime differences were resolved throughout the image. This shows that the id 220 detector is well applicable to IR FLIM. Summary Fig. 7: Decay data (blue spots) and IRF (green) in a selected pixel We have shown that the combination of the id 220 InGaAs SPAD and the bh SPC-150 TCSPC card is able to record fluorescence decay curves of IR dyes, time-of-flight distributions of photons in scattering media, and, with a confocal scanner, FLIM images of samples under a microscope. Unfortunately, the fluorescence lifetimes of currently available IR dyes are extremely short. The fluorescence lifetime obtained for IR1061 was about 50 ps. Nevertheless, the lifetime and its variation were well detectable in the FLIM data. Although the results described above were obtained with an SPC-150 card in a Simple-Tau system they can be considered typical of all bh TCSPC devices. Existing TCSPC systems may therefore be upgraded for IR detection with the new detector. References 1. id220-fr Cost-effective module for asynchronous single-photon counting at telecom wavelengths. Available on www.idquantique.com 2. W. Becker, Advanced time-correlated single-photon counting techniques. Springer, Berlin, Heidelberg, New York, 2005 3. W. Becker, The bh TCSPC handbook. 5th edition, Becker & Hickl GmbH (2012), available on www.beckerhickl.com 4. BDS-SM picosecond diode lasers. Datasheet. Available on www.becker-hickl.com 5. Becker & Hickl GmbH, DCS-120 Confocal Scanning FLIM Systems. User handbook. Available on www.beckerhickl.com 6. Becker & Hickl GmbH, SPCImage Data Analysis Software for Fluorescence Lifetime Imaging Microscopy. User handbook. Available on www.becker-hickl.com Contact: Wolfgang Becker Becker & Hickl GmbH becker @becker-hickl.com Leonard Widmer id Quantique leonard.widmer@idquantique.com id-220-tcspc-04 April 2013 5