Electromotoric actuators for stroke valves

Similar documents
Electromotoric actuators for valves

SAT.. Electromotoric actuators for valves ACVATIX. with a 5.5 mm stroke and 300 N positioning force

SAY..P.. A6V ACVATIX Electromotoric actuators for valves. with a 15 mm stroke

SAV.. ACVATIX Electromotoric actuators for valves. with a 20/40 mm stroke

SAL.. ACVATIX Electromotoric rotary actuators for butterfly or slipper valves. with 90 rotary angle

SAY..P.. A6V ACVATIX Electromotoric actuators for VPI46. with a 15 mm stroke

SAX.. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

SAX.. ACVATIX Electromotoric actuators for valves. with a 20 mm stroke

SAX..P. Electromotoric actuators for valves ACVATIX. with a 20 mm stroke

Electromotoric actuators

Rotary actuators for ball valves

Air damper actuators. OpenAir GDB..1E. Electronic motor driven actuators for open-close, three-position and modulating control

Air damper actuators. OpenAir GSD...1A. Electric motor-driven rotary actuators for open-close, three-position and modulating control

Configured air damper actuators 6FU11xx-xDxxx-xxxx

Rotary actuators for ball valves

Air damper actuators

Air damper actuators Rotary version with spring return, AC 24 V / DC V / AC 230 V

Rotary actuators for ball valves

Wireless multizone receiver RDE-MZ6

Modulating control valves with magnetic actuator, PN 16

Room Temperature Controllers. for heating and cooling systems

Room Temperature Controllers. for heating and cooling systems

Room Temperature Controllers. for heating and cooling systems

QAC910. Meteo Sensor. Synco living

GLB...9. Ball Valve actuators. Building Technologies HVAC Products. for valves VAI61... AC 24 V / AC 230 V

Room air quality sensors

Modulating controlled actuators AME 10, AME 20, AME 30 AME 13, AME 23, AME 33 - with DIN EN certified safety function (spring down)

Technote. Actuator Frese OPTIMA. Application. Features actuator DN15-DN32. Features actuator DN40-DN50. Approval.

Rotary actuators for ball valves

Rotary actuators for ball valves

FA-3300 Heavy Duty Electric Actuator. Features and Benefits. FA-3300 Actuator with VG8000 valve. Constant running time. Fixed close-off force.

Rotary actuators for ball valves

Overview of types. Technical data. T5-NRDVX24-SR-T-.. en v Subject to changes 1 / 3

Power amplifier for thermic valve actuators

AC/DC 24 V, 50/60 Hz. Functional data Variable Settings. DC V, max. 0.5 ma. End point DC V... 4 ma ma Non-variable

RF converter WTX660-E05060

Compact room automation stations, BACnet MS/TP, AC 24 V

Technical Instructions Document No EA GQD October 25, OpenAir GQD Series

Technical Instructions Document No EA GQD June 23, OpenAir

OpenAir Linear actuators GDB/GLB...2 Technical basics. CE1Z4664en Building Technologies

Compact room automation stations, BACnet/IP, AC 24 V

USER S MANUAL POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER ZSP 41 POWER SUPPLY - ISOLATOR - SIGNAL CONVERTER SIGNAL MULTIPLIER ZSP 41/2

QFM21... Duct sensors. Symaro. for relative humidity and temperature

Electrical data Nominal voltage AC 230 V Nominal voltage frequency

Overview of types. Technical data

Technical data. Safety notes. T3-LR24A-SR en v Subject to changes 1 / 2

Actuator for modulating control AME 435

Functional data Factory settings Variable Settings

Provides line voltage capable single Pole Double-Throw (SPDT) switch and 140Ω, 1KΩ, 2KΩ or 10KΩ feedback potentiometric.

Power consumption In operation At rest For wire sizing. 1.5 W at nominal torque 0.4 W 4 VA Connection Cable 1 m, 3 x 0.75 mm 2

Electrical data Nominal voltage AC 24 V, 50/60 Hz DC 24 V. Power consumption In operation At rest For wire sizing

QPM Series Indoor Air Quality Duct Sensors

Differential pressure sensors

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

Actuators for modulating control AME 85, AME 86

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar

Outside Temperature Sensors

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

OEM pressure sensor For industrial applications Models O-10 (T), O-10 (5)

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

Technical data. Parameterisable damper actuator in the

Manual triggering of the adaption by pressing the «Adaption» button or with the PC-Tool

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

SINEAX B 811 Power Pack with additional Functions

Power consumption In operation At rest For wire sizing. 150 s / C Sound power level Motor. Emergency setting function 61 db (A)

Spring Return DuraDrive Proportional Actuator

MODEL: MRP5. Final Control Elements. [2] TERMINAL BOX T: With

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

EY-EM 527: Remote I/O module, ecolink527

OEM pressure transmitter for general industrial applications Models O-10 (T), O-10 (5)

Electronic Air / Fuel Ratio Control System

MODEL: MRP6. Final Control Elements

Actuators for modulating control AME 55, AME 56

Servomotor for butterfly valves VF, VFH. delta-elektrogas.com EE157-01/16

Power consumption Operation At rest Wire sizing

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Room Temperature Controllers. for heating and cooling systems

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Technical data. T2-SM230ASR en v Subject to changes / 3. Electrical data Nominal voltage AC

Technical data V phase cut, input impedance 8.2 k Position feedback (measuring voltage U) DC V, max. 0.5 ma Start point DC

Type 3374 Electric Actuator

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Power consumption In operation At rest For wire sizing

Plug-in amplifier. Table of contents. Features. RE 30264/07.12 Replaces: Type VT-SSPA1. Component series 2X 1/8

Room Sensors. for relative humidity and temperature

Room Sensors. In ventilating and air conditioning plants to acquire relative humidity and temperature in rooms. Humidity measuring range

Technical data. Safety notes. Power consumption In operation At rest For wire sizing

Room Temperature Controllers. for heating and cooling systems

Instruction Manual T5140 T5141 T5145 T5240 T5241 T5245. Programmable transmitter of CO2 concentration with 4-20 ma output. with 0-10 V output

TS-9100 Electronic Sensors and Transducers. Features and Benefits. G Wide range of enclosures and signal outputs

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

COMMERCIAL. GA Series - Actuator Operating Instructions. GA Non-Spring Return Actuator - (GA24-562) 04/08 /15

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

DP2500 DP0100 DP0250 Differential Pressure Transmitter

LOW VOLTAGE CONVERTER WITH THREE POINT GALVANIC INSULATION

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

MINI-PS AC/24DC/1.3

Transcription:

s ACVATIX Electromotoric actuators for stroke valves SAS.. Electromotoric actuators with 5.5 mm stroke and 400 N positioning force SAS31.. Operating voltage AC 230 V, 3-position control signal Operating voltage AC 24 V / DC 24 V, control signal DC 0...10 V / DC 4...20 ma / 0...1000 Ω SAS81.. Operating voltage AC/DC 24 V, 3-position control signal For direct mounting on valves; no adjustments required Manual adjuster, position indicator and status indication per LED Optional functions with auxiliary switch 2015-05-19 Building Technologies

Features For the operation of 2-port and 3-port valves: Types V..G44.. and VVG55.. 5.5 mm stroke As control or shutoff valves in heating and ventilation systems. Functions Function Description Type 3-position control Modulating control Positioning signal and flow characteristic selection Position feedback U Calibration Detection of valve seat Detection of foreign bodies Forced control Z (Z mode) A 3-position signal drives the actuator via connection terminals Y1 or Y2. The required position is transferred to the valve. The modulating positioning signal drives the actuator steplessly. The positioning signal range (DC 0...10 V / DC 4...20 ma / 0...1000 Ω) corresponds in a linear manner to the positioning range (fully closed...fully open, or 0 100 % stroke). Setting the DIL switches. Factory setting: All DIL switches set to OFF. Signal used to acquire the position, fed back via an input. During commissioning, the actuator detects the valve s end positions and files the exact stroke in its internal memory. The actuators feature force-dependent valve seat detection. After calibration, the exact valve stroke is filed in the actuator s memory. After detection of clogging, 3 attempts are made to overcome clogging. If the attempts made are unsuccessful, the actuator continues to follow the positioning signal within the restricted range only (LED continues to blink red). Forced control serves for overriding automatic mode and is implemented in the structure. SAS31.. SAS81.. Type summary Product no. Stock no. Operating voltage Positioning signal Power consumption Posit. time Fail safe funct./ Spr. return time Manual adjuster SAS31.00 S55158-A106 2.8 / 2.4 VA 5) 120 s No Yes SAS31.03 S55158-A107 3.5 / 2.9 VA 5) 30 s AC 230 V 3-position SAS31.50 S55158-A108 3.5 / 2.9 VA 5) 120 s Yes / <28 s 6) No SAS31.53 S55158-A109 5.5 / 3.8 VA 5) 30 s Yes / <14 s 6) SAS61.03 S55158-A100-A100 5.3 / 4.5 VA 5) No SAS61.03U S55158-A106 DC 0 10 V 5.3 / 4.5 VA SAS61.33 S55158-A101 AC/DC 24 V DC 4 20 ma 5.9 / 4.8 VA 5) 30 s SAS61.33U 0 1000 Ω S55158-A101-A100 5.9 / 4.8 VA Yes / <14 s 6) Yes Position feedback 5) 2) DC 0 10 V 5) 2) SAS61.53 S55158-A102 5.8 / 5.0 VA 5) No SAS81.00 S55158-A103 2.2 / 2.0 VA 5) 120 s 5) 2) SAS81.00U S55158-A103-A100 2.2 / 2.0 VA No SAS81.03 S55158-A104 2.5 / 2.1 VA 5) AC/DC 24 V 3-position Yes 5) 2) SAS81.03U S55158-A104-A100 2.5 / 2.1 VA 30 s SAS81.33 S55158-A105 3.4 / 2.4 VA 5) Yes / <14 s 6) 5) 2) SAS81.33U S55158-A105-A100 3.4 / 2.4 VA 2) 3) Cable gland: M16 and M20 (ISO50262) Cable gland: ½ (UL514C) Approbation: CE 4) 5) 6) Approbation: CE and UL (only 24 V) Second value: Power consumption in neutral position Spring return time increased slightly at low temperatures Remark 3) 4) 2 / 12 Building Technologies 2015-05-19

Accessories Electrical Accessory Auxiliary switch ASC10.51 Mechanical Accessory Weather shield ASK39.2 1 Ordering (Example) Product no. Stock no. Description Quantity SAS31.00 S55158-A106 Actuator 1 + auxiliary components (connections, auxiliary switches ) Delivery Actuator, valve and accessories are supplied in individual packs. Spare parts Stock number Description 8000069479 Housing cover with screws and light conductor as an assembly, without laser marking 1 Equipment combinations Valves PN16 Actuators SAS.. VVG44.. (2-port) VXG44.. (3-port) G k vs p S p max DN Medium: 1 120 C [Inch] [m 3 /h] [kpa] [kpa] VVG44.15-.. VXG44.15-.. 15 G 1 B 0.25 / 0.4 / 0.63 1600 400 VVG44.15-.. VXG44.15-.. 15 G 1 B 1 / 1.6 725 400 VVG44.15-.. VXG44.15-.. 15 G 1 B 2.5 / 4 400 400 VVG44.20-6.3 VXG44.20-6.3 20 G 1 ¼ B 6.3 750 400 VVG44.25-10 VXG44.25-10 25 G 1 ½ B 10 400 400 VVG44.32-16 VXG44.32-16 32 G 2 B 16 250 250 VVG44.40-25 VXG44.40-25 40 G 2 ¼ B 25 125 125 Valves PN 25 Actuators SAS.. VVG55.. (2-port) G k vs p S p max Medium: 1 130 C DN [Inch] [m 3 /h] [kpa] [kpa] VVG55.15-.. 15 G ¾ B 0.25 / 0.4 / 0.63 2500 1200 VVG55.15-.. 15 G ¾ B 1 / 1.6 / 2.5 2000 1200 VVG55.20-4 20 G 1 B 4 1000 1000 VVG44.25-6.3 25 G 1 ¼ B 6.3 800 800 With ALG..B fittings up to 100 C 2) Pressure compensated 3 / 12 2015-05-19 Building Technologies

Product documentation Title Topic Document ID Actuators SAS.., SAT.. for valves Basic Documentation Detailed information about the SAS.. actuators CE1P4041en Related documents such as environmental declarations, CE declarations, etc., can be downloaded at the following Internet address: http://siemens.com/bt/download Notes Safety Caution National safety regulations Failure to comply with national safety regulations may result in personal injury and property damage. Observe national provisions and comply with the appropriate safety regulations. Engineering SAS31.., SAS81.. 3-position actuators must have one specific controller each; refer to Connection diagrams. Up to 10 actuators can drive in parallel on a controller output with a rating of 1 ma. Modulating actuators have an input impedance of 100 kω. Mounting Mounting positions Indoor use Outdoor use Only in connection with weather shield ASK39.2, housing protection IP54 remains unchanged Maintenance The actuators are maintenance-free. Mounting: Do not touch the valve coupling if the components (valve/pipes) are hot If necessary, disconnect electrical connections from the terminals The actuator must be correctly fitted to the valve before recommissioning. 4 / 12 Building Technologies 2015-05-19

Disposal The device is considered an electronics device for disposal in terms of European Directive 2012/19/EU and may not be disposed of as domestic garbage. Dispose of the device through channels provided for this purpose. Comply with all local and currently applicable laws and regulations. Warranty Technical data on specific applications are valid only together with products listed under "Equipment combinations". rejects any and all warranties in the event that third-party products are used. Note When using the actuators in connection with valves of other manufacture, correct functioning must be ensured by the user, and will assume no responsibility. Technical data Power supply SAS.. Operating voltage SAS31.. AC 230 V ± 15 % Frequency External supply line protection (EU) AC 24 V ± 20 % / DC 24 V +20 % / -15 % or AC 24 V class 2 (US) SAS81.. AC/DC 24 V ± 20 % or AC 24 V class 2 (US) 45 65 Hz 6 A...10 A slow or Circuit breaker max. 13 A Characteristic B, C, D according to EN 60898 Power source with current limitation of max. 10 A Power consumption at 50 Hz Stem retracts / extends - see "Type summary" Function data Positioning time with the specified nominal stroke Positioning force Nominal stroke Permissible medium temperature SAS..0 120 s SAS..3 / SAS..3U 30 s 400 N 5.5 mm valve fitted 1 130 C Signal inputs Y positioning signal SAS31../SAS81.. 3-position DC 0 10 V / DC 4 20 ma / 0 1000 Ω (DC 0 10 V) Current draw 0.1 ma Input impedance 100 kω (DC 4 20 ma) Current draw DC 4...20 ma ± 1 % Input impedance 500 Ω Parallel operation 10 (depending on controler output) 5 / 12 2015-05-19 Building Technologies

Forced control Positioning signal Z R = 0 1000 Ω, G, G0 Position feedback R = 0 1000 Ω stroke proportional to R Z connected to G max. stroke 100 % Z connected to G0 min. stroke 0 % Voltage max. AC 24 V +20 % / max. DC 24 V +20 % / -15 % Current draw 0.1 ma U DC 0 10 V ± 1 % Connecting cable Load impedance Load > 10 kω res. max. 1 ma Wire cross-sectional areas 0.75 1.5 mm 2, AWG 20 16 Cable entries SAS.. (EU) 1 entry Ø 16.4 mm (for M16) 1 entry Ø 20.5 mm (for M20) Degree of protection SAS..U (US) 2 entries Ø 21.5 mm for ½ tube connection Housing protection (Mounting position) IP 54 as per EN 60529 2) (vertical) Insulation class As per EN 60730 Environmental conditions Actuators SAS31.. AC 230 V Actuators AC / DC 24 V Actuators SAS81.. AC / DC 24 V Operation IEC 60721-3-3 Climatic conditions II III III Class 3K5 Mounting location Indoors, outdoors 3) Temperature general -5 55 C Humidity (noncondensing) 5 95 % r. F. Transport IEC 60721-3-2 Climatic conditions Class 2K3 Temperature -25 70 C Humidity <95 % r. F. Storage IEC 60721-3-1 Directives and Standards Product standard Electromagnetic compatibility (Application) Temperature -15 55 C Humidity 5 95 % r. F. EN60730-x EU Conformity (CE) CE1T4581xx 4) RCM Conformity CE1T4581en_C1 4) For residential, commercial and industrial environments UL, cul AC / DC 24 V UL 873 http://ul.com/database 6 / 12 Building Technologies 2015-05-19

Environmental compatibility Dimensions / Weight The product environmental declaration CE1E4581 contains data on environmentally compatible product design and assessments (RoHS compliance, materials composition, packaging, environmental benefit, disposal). See "Dimensions" Accessories 5) Auxiliary switch ASC10.51 Switching capacity 2) 3) 4) 5) External supply line protection US installation, UL & cul AC 24 230 V, 6 (2) A, floating See section power supply AC 24 V class 2, 5 A general purpose AWG = American wire gauge. Wire cross-sectional areas and fuses have to be well-matching, which is the responsibility of the planner / installer. Observe norm of protection measures - protection against overcurrent: IEC 60364-4-43:2008 resp. german adoption HD 60364-4-43:2010. Also with weather shield ASK39.2 Outdoors always with weather shield ASK39.2, housing protection IP54 remains unchanged The documents can be downloaded from http://siemens.com/bt/download UL recognized component 7 / 12 2015-05-19 Building Technologies

Diagrams Internal Diagrams SAS31.. SAS31.5.. Accessory plug-in space A 1x ASC10.51 ASC10.51 SAS81.. SAS81.33, SAS81.33U 8 / 12 Building Technologies 2015-05-19

Connection terminals SAS31.. AC 230 V, 3-position System neutral (SN) Positioning signal (actuator s stem extends / actuator s spindle turns cw ) Positioning signal (actuator s stem retracts / actuator s spindle turns ccw 2) ) SAS31.5.. AC 230 V, 3-position System neutral (SN) Positioning signal (actuator s stem extends / actuator s spindle turns cw ) Positioning signal (actuator s stem retracts / actuator s spindle turns ccw 2) ) Fail safe function AC/DC 24 V, DC 0 10 V / 4 20 ma / 0 1000 Ω System neutral (SN) System potential (SP) Positioning signal for DC 0 10 V / 4 20 ma Measuring neutral Position feedback DC 0 10 V Positioning signal forced control AC/DC 24 V, 0...1000 Ω SAS81.. AC/DC 24 V, 3-position System potential (SP) Positioning signal (actuator s stem extends / actuator s spindle turns cw ) Positioning signal (actuator s stem retracts / actuator s spindle turns ccw 2) ) SAS81.33U AC/DC 24 V, 3-position System potential (SP) Positioning signal (actuator s stem extends / actuator s spindle turns cw ) Positioning signal (actuator s stem retracts / actuator s spindle turns ccw 2) ) System neutral (SN) Electrical accessories ASC10.51 Auxiliary switch. Adjustable switching points, AC 24 230 V System potential (SP) Closing (actuator s stem extends / actuator s spindle turns cw ) Opening (actuator s stem extends / actuator s spindle turns cw ) cw = clockwise 2) ccw = counter-clockwise 9 / 12 2015-05-19 Building Technologies

Connection diagrams SAS31.. SAS31.5.. SAS61.33 / SAS61.33U / SAS61.53 SAS81.. SAS81.33, SAS81.33U A F1 F2 F3 F4 L Actuator Temperature limiter Frost protection thermostat; terminals: 1 2 frost hazard / sensor is interrupted (thermostat closes with frost) 1 3 normal operation Temperature detector Frost protection monitor with 0 1000 Ω signal output, does NOT support QAF21.. or QAF61.. Phase M Measuring neutral N Neutral N1 Controller SN System neutral SP System potential AC/DC 24 V U Position feedback Y Positioning signal Y1, Y2 Positioning signals Z Positioning signal forced control 21 Fail safe function 10 / 12 Building Technologies 2015-05-19

Dimensions Actuators SAS.. with manual adjuster Product no. A B C C1 C2 D E [kg] 1 2 SAS.. 151 80 93 21,9 71.1 29,9 21,8 100 200 0.4 M16 M20 With ASK39.2 155 126 248 99 149 29,9 21,8 100 200 0.5 M16 M20 SAS..U: ½ (Ø 21,5 mm) Actuators SAS.. without manual adjuster Product no. SAS.. A B C C1 C2 D E 1 2 [kg] 137.6 2) 80 106.5 21.9 84.6 29,9 21,8 100 200 0.68 M16 M20 151 With ASK39.2 155 126 248 99 149 29,9 21,8 100 200 0.83 M16 M20 Black cover 2) Blue manual adjuster 11 / 12 2015-05-19 Building Technologies

Revision numbers Product no. SAS31.00 SAS31.03 SAS31.50 SAS31.53 SAS61.03 SAS61.03U SAS61.33 SAS61.33U SAS61.53 SAS81.00 SAS81.00U SAS81.03 SAS81.03U SAS81.33 SAS81.33U Valid from rev. no. Issued by Switzerland Ltd Building Technologies Division International Headquarters Gubelstrasse 22 6301 Zug Switzerland Tel. +41 41-724 24 24 www.siemens.com/buildingtechnologies Switzerland Ltd, 2015 Technical specifications and availability subject to change without notice. Document ID Issue 2015-05-19