WAVEFORM CORRECTOR (WAVEFORM CORRECTORS) REPLACES SURGE PROTECTION DEVICES (SPD) PREVIOUSLY KNOWN AS (TVSS)

Similar documents
UL rd Edition SPD

ULTRA-K Series 600K - he

First Draft Language

PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian)

SECTION DISTRIBUTION SWITCHBOARDS

Power Processor - Series 700F 10KVA to 150KVA

LIFE LINE PRODUCT SPECIFICATION FOR A 1 TO 3 KVA, SINGLE PHASE, POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING

POWER DELEGATOR SERIES 7200A POWER DISTRIBUTION UNIT WITH POWER CONDITIONING GENERAL SPECIFICATIONS

2.2 American National Standards Institute Corporation and its applicable standards C39.1, C80.1, C89, C84.1.

SECTION OVERCURRENT PROTECTIVE DEVICE COORDINATION STUDY

SPECIAL SPECIFICATION 6609 Fiber Optic Color Video and Data Transmission Equipment

B. Manufacturers: Square-D, G.E. or Westinghosue.

Wisconsin Contractors Institute Continuing Education

PIRANHA 3 (3-phase, Power Conditioning Voltage Regulator)

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 2/9/11 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

MODEL 3810/2 Line Impedance Stabilization Network

Michigan State University Construction Standards SWITCHBOARDS, PANELBOARDS, AND CONTROL CENTERS PAGE

Brown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS

1. All electrical switches and outlets used shall be equal to Hubbell heavy duty, specification grade or equivalent quality.

CONSULTANT PROCEDURES & DESIGN GUIDELINES Liquid-Filled Utility Transformers UNIVERSITY OF MISSOURI

SECTION 16483D ADJUSTABLE FREQUENCY DRIVE - MICRODRIVE (MVX <10-HP)

PREFACE ********************************************************** IT IS NOT INTENDED THAT THESE STANDARDS BE COPIED AND USED AS A SPECIFICATION!

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

Variable Transformers Product Design & Engineering Data

Model 3725/2M. Line Impedance Stabilization Network (LISN) User Manual

Electrical Wiring: Commercial, Seventh Canadian Edition

Liebert Datawave GUIDE SPECIFICATIONS kva Magnetic Synthesizer Power Conditioning System

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

Power-Sure 700. Technical Data TD158001EN. Contents

SPECIFICATION SWITCHING POWER SUPPLY SINGLE POWER 250W BEST POWER SOLUTIONS, INC. 9F, NO.196-7, SEC.3, TA-TUNG RD SHI CHIH, TAIPEI, TAIWAN, R.O.C.

1995 Metric CSJ SPECIAL SPECIFICATION ITEM Multimode Video Fiber Optic Transmission Equipment

SUGGESTED SPECIFICATION for Series 300 Automatic Transfer Switches

ISO Rules Part 500 Facilities Division 502 Technical Requirements Section Aggregated Generating Facilities Technical Requirements

FACILITY RATINGS METHOD TABLE OF CONTENTS

S11 Adjustable Speed Drive Engineering Specification

Liebert Datawave. GUIDE SPECIFICATIONS kva Magnetic Synthesizer Power Conditioning System 1.0 GENERAL

Low Voltage Power Factor Correction Equipment Specifications Automatic, Automatic Detuned, Automatic Tuned

SECTION COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION

MECKLENBURG COUNTY. Land Use and Environmental Service Agency Code Enforcement 9/8/10 ELECTRICAL CONSISTENCY MEETING. Code Consistency Questions

a) Determine the smallest, standard-sized circuit breaker that should be used to protect this branch circuit.

PRODUCT FEATURES TYPICAL APPLICATIONS

SPECIAL SPECIFICATION 6734 RS-232 Optical Modem

7. INSPECTION AND TEST PROCEDURES

Topic 6 Quiz, February 2017 Impedance and Fault Current Calculations For Radial Systems TLC ONLY!!!!! DUE DATE FOR TLC- February 14, 2017

Section 16621A - AUTOMATIC TRANSFER SWITCH. Part 1 General

INTELLIMETER REGISTER

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

This section applies to the requirements for the performance of power system studies by both the Design Engineer and the Contractor.

Grounding for Power Quality

NEC 2014 Code Changes

StatiVolt. Inverter UPS Systems. Features. Contents

SAFETY AND HEALTH STANDARD ELECTRICAL GROUNDING Effective Date: 07/17/10 Standard: Document Number: KUCSH0039 Rev: 4

Design Approaches for Hospital Distribution Systems With Considerations for Future Expansion, Operator Safety, and Cost

DPM - Mesta Electronics, Inc. Low Voltage Active Harmonic Filters

VARIABLE FREQUENCY DRIVE SPECIFICATION

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class

SECTION AUTOMATIC TRANSFER SWITCH

OPERATING, METERING AND EQUIPMENT PROTECTION REQUIREMENTS FOR PARALLEL OPERATION OF LARGE-SIZE GENERATING FACILITIES GREATER THAN 25,000 KILOWATTS

SECTION PANELBOARDS

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL

Phoenix DX Clean Power (18 Pulse) AC Drive

2014 NEC Changes Part 1

AN EXAMPLE OF A STANDARD ARC FLASH PPE LABELING STRATEGY

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

SPECIFICATION SWITCHING POWER SUPPLY BPS-300SP/2U 6-OUTPUT WITH ACTIVE PFC FUNCTION SINGLE POWER 300W BEST POWER SOLUTIONS, INC.

SPECIAL SPECIFICATION 6419 Fiber Optic Video Transceiver with Data

SPECIAL SPECIFICATION 1533 Drop/Insert Multiplexor/Demultiplexor

SPECIFICATION REDUNDANT POWER SUPPLY HOT-SWAPPABLE 370W+370W

7P Series - Surge Protection Device (SPD) Features 7P P P

35 kv Class M.O.V.E. DirectConnect elbow arrester

TOSHIBA International Corp

Electrical Arc Hazards

Single Phase Soft Starters

INPUT VOLTAGE STARTING MINIMUM NORMAL MAXIMUM MAXIMUM INPUT RANGE VOLTAFE VOLTAGE VOLTAGE VOLTAGE CURRENT

2018 Consultant s Handbook Division 26 Electrical ARC Flash Hazard Analysis

SPECIAL SPECIFICATION 1789 Fiber Optic RS-232 Data Modem

ENERGY SAVINGS THROUGH POWER CONDITIONING WITH THE PowerGUARD SYSTEM

3Ø Short-Circuit Calculations

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY. Section ELECTRICAL IDENTIFICATION

TABLE OF CONTENT

VF-nC1 Adjustable Speed Drive Engineering Specification

Table of Contents. 1 Introduction. 2 System-Level Electrostatic Discharge (ESD) and Electrical Fast Transient (EFT) 3 Electromagnetic Interference

TE60 60W Single Output External Power Test & Measurement/Industrial Series

E S C R I P T I V E B U L L E T I N .,.,.,. Bulletin DB-106. October, Square D Company Power System Studies ---1 I SQU ARED COMPANY --

Table of Contents. Facility EMI Filter Products

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Drop/Insert Multiplexor/Demultiplexor

AF91 Adjustable Frequency Drives Series B

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.

Design Specifications Low Voltage Active Harmonic Filter

INTERIM ARRANGEMENTS FOR GRID TIED DISTRIBUTED ENERGY RESOURCES. Technical Requirements for Grid-Tied DERs

THREE PHASE PAD MOUNTED DISTRIBUTION TRANSFORMER ARC FLASH TESTING JUNE 23, 2009 FERRAZ SHAWMUT HIGH POWER LABORATORY NEWBURYPORT, MA

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: Electrical Standards

Metal Oxide Varistor Elbow (M.O.V.E.) Surge Arrester

DESIGN CHECKLIST INTRODUCTION

Short Circuit Current Calculations

Course 11 Distribution Transformer Applications Instructor: David R. Smith, PE Due: April 24, 2017 (EV), April 25, 2017 (LC)

PowerFlex 400 Submittal

INDUSTRIES, INC. HOWARD. Standard Power 1-Lamp-T8 STANDARD ELECTRONIC SMALL CASE - INSTANT START

Top wiring permanent magnet latching For non-motor loads, lighting, heating NEMA sizes to 300 A 2-, 3-, and 4-pole configurations

Transcription:

WAVEFORM CORRECTOR (WAVEFORM CORRECTORS) REPLACES SURGE PROTECTION DEVICES (SPD) PREVIOUSLY KNOWN AS (TVSS) 1 PART 1: GENERAL This section describes materials and installation requirements for low voltage Waveform Correctors for the protection of all AC electrical circuits. Devices to be installed at designated service entrance equipment, distribution panels, electronic equipment, and receptacle devices. 1.1 SUBMITTALS A. Submit product data on each Waveform Corrector indicating the following: 1. Type of construction and components 2. Model number and conductor sizes 3. Dimensional drawings for each model showing mounting and connection arrangements 4. Clamping voltage for each model number 5. Attenuation roll off curve and noise attenuation in db per decade 6. Operating temperature and frequency 7. Listing, safety standards and compliances B. Submit manufacturer s NRTL certified test data and nameplate data for each model of Waveform Corrector. C. Submit electrical single-line diagram showing location and model of each Waveform Corrector. 1.2 TESTING, WARRANTY AND DURABILITY Manufacturer must provide independent testing on repetitive capability and maximum surge current rating of all Waveform Corrector units. This shall be performed at a nationally recognized lab not affiliated with the manufacturer. 1.2.1 Testing A. Single pulse surge current capacity: single pulse surge current tested in a mode at rated surge currents. B. Single pulse surge current capacity test: an initial UL 1449 defined 1.2 x 50us, 6000V open circuit voltage waveform and an 8 x 20us, 500A and 3kA short circuit current waveform is applied to benchmark the unit s voltage protection rating (VPR). C. IEEE C62.41 category A1.5uS*100 khz, 2kV, 70 amp ring wave should be tested on Waveform Corrector. Testing should be performed with the initial pulse in the positive direction. Testing should be performed at 90,180 and 270 electrical degrees to help establish Waveform Corrector performance at the positive peak, the zero crossing and the negative peak of the waveform. D. IEEE C62.41 category B3.5uS*100 khz, 6kV, 500 amp ring wave should be tested on Waveform Corrector. Testing should be performed with the initial pulse in the positive direction. Testing should be performed at 90,180 and 270 electrical degrees to help establish Waveform Corrector performance at the positive peak, the zero crossing and the negative peak of the waveform E. IEEE C62.41, Category B1 1.5/50uS & 8/20uS, 2kV, 1kA amp combination wave (pulse in positive direction) should be tested on Waveform Corrector. Testing should be performed with the pulse in the positive direction. F. IEEE C62.41, Category B3 1.5/50uS & 8/20uS, 6kV, 3kA amp combination wave

(pulse in positive direction) should be tested on Waveform Corrector. Testing should be performed with the pulse in the positive direction G. Random noise testing should be tested on Waveform Corrector. Random noise should be from 1 khz to 100 khz, analogous to noise generated by Variable Frequency Drives. Waveform Corrector should suppress the noise levels to at least 20dB from 1 khz to 100 khz. 1.2.2 Durability A. IEEE C62.41, Category B3 1.5/50uS & 8/20uS, 6kV, 3kA amp combination wave should be imposed on the Waveform Corrector. Waveform Corrector attenuation levels should be monitored and recorded to at least 1900 repetitive consecutive surges. B. Performance (energy absorption) of the Waveform Corrector after 10000 surges should not deviate more than 5% from the Waveform Corrector s response of the initial surge test. 1.2.3 Warranty A. Five years on non-modular units. B. Ten years on Modular units. 1.3 QUALITY ASSURANCE A. Regulatory Labeling: 1. Provide units that are listed and labeled by NRTL. B. The specified unit shall be designed, manufactured, tested and installed in compliance with the above references. The unit shall be Listed by Underwriters Laboratories to UL 1449 3 rd Edition. C. ANSI Compliance: Use Waveform Corrector devices in compliance with the recommendations of IEEE C62.41.1, IEEE C62.41.2, and IEEE C62.45. D. All the units should comply with NEMA LS-1, Low voltage surge p rotective Devices. E. Each product should be tested individually for quality control F. Each product should have unique serial number so that it can be easily traceable. 2 PART 2: PRODUCTS 2.1 GENERAL A. All Waveform Correctors for power circuits, provided under this section, shall be the product of a single manufacturer. B. All Waveform Correctors for power circuits, provided under this section shall be designed to meet the following housing and mounting criteria: 1. For Waveform Corrector devices used in Outside Plant applications where the device is internal to a cabinet or common equipment vault (CEV) the Waveform Corrector shall be capable of wall mounting with its housing rated to at least NEMA 4. 2. For Waveform Corrector devices used in MSO, CO, or other occupied premises the Waveform Corrector shall be capable of wall mounting and have a housing rated to at least NEMA 4. C. Waveform Correctors can be either modular or non-modular in design. D. Waveform corrector devices shall be capable of performance at ambient temperatures between -40 o C to 65 o C at relative humidity ranging from 0 percent to 95 percent, and at altitudes ranging from sea level to 12,000 feet. E. Waveform Corrector devices shall be fused such that they disconnect the Waveform

Corrector from the electrical source should the Waveform Corrector fail. The product s fusing shall be certified to survive the full rated surge handling capacity of the unit and to afford safety protection from thermal overloads and short circuits. Waveform Corrector shall meet UL 1449 3 rd Edition F. Waveform Corrector devices shall have been tested and certified (Listed) by an NRTL to have a short circuit current rating (SCCR) equal to or greater than the available fault current in accordance with NEC Section 285. Series ratings expressly prohibited. G. Waveform Corrector devices shall be labeled such that they show the short circuit current rating (SCCR) in compliance with the requirements of the most current revision of UL 1449 in force upon the date of installation. H. Waveform Corrector devices that absorb, dissipate, correct the waveform, and do not utilize the ground conductor as a path for power surge energy, supersede SPD devices that meet UL 1449 minimum requirements in force upon the date of installation. I. Design Waveform Corrector devices for the specific type and voltage of the electrical service. Single-phase, split phase, and three-phase wye-configured systems shall have L- N. Grounded delta-configured systems shall have L-L. As recommended by the IEEE Emerald Book, Waveform Correctors shall not shunt energy to ground or contribute frequency energy leakage to the ground conductor. J. Waveform corrector s active waveform tracking components shall have a maximum continuous operating voltage (MCOV) of no less than 110% of the nominal phase- toneutral operating voltage for 120V power systems. It can have no less than 110% of the nominal phase-to-neutral voltage for 230V and higher power systems, and not less than 110% of the nominal phase-to-phase voltage for delta systems. K. All Waveform Corrector devices will provide filtering across an extended range from 2.5kHz to 2.5MHz, with greater than -30 db filtering across the total frequency spectrum. L. SPD filter options that meet minimum standards only at peak resonance shall not meet specification and are expressly prohibited regardless of UL minimum compliance. M. Waveform Corrector performance shall be tested by a 3 rd party to IEEE C62.41 standards for the following categories: 1. A1 (low system exposure, 2kV, 70 amp ring wave) 2. B1 (low system exposure, 2kV, 1kA combination wave) 3. B3 (high system exposure, 6kV, 500 amp ring wave) and B3 (high system exposure, 6kV, 3kA combination wave). 4. Third party data shall be submitted N. Waveform Correctors performance for the frequency noise between 1kHz to 90kHz should be third party tested and data should be submitted 2.2 MANUFACTURER Manufacturer list is in alphabetical order and not in order of preference. A. Environmental Potentials B. (Other Qualified Manufacturer inserted here) 2.3 SERVICE ENTRANCE AC Waveform Corrector A. Provide Waveform Corrector meeting IEEE C62.41.1 and IEEE C62.41.2 Location in accordance with Category C. Must also be UL96A compliant. dissipation and filtering circuits. SPD devices incorporating MOV, SAD, gas tube, and/or Selenium technology solely are expressly prohibited as to maintain safety ground integrity

C. Surge current capacity shall be not less than the following: 1. L-N Capacity: 320 ka/mode 2. L-L Capacity: 320kA/mode D. Due to sensitivity of electronic based devices and negative effects of high frequency noise on an electrical system, Waveform Corrector must be installed and it must filter noise from 2.5 khz to 2.5 MHz with greater than -30 db filtering across the total simply shunt to ground shall be expressly prohibited. E. Waveform Corrector should not only provide low impedance between phase and neutral, but physically convert the electrical noise (energy) and voltage surges to heat, F. Waveform Corrector housing shall be in an enclosure that has the same NEMA rating, or higher, as the equipment it protects. G. Waveform Corrector shall be installed EXTERNAL to Switchgear or in an explosion and vapor proof separate enclosure inside the gear. Waveform Corrector enclosure does not count as an explosion and vapor proof enclosure. H. UL 1449 maximum suppression voltage shall not be more than: 1. 1500 Volt for 277/480 Volt, 3phase, 4wire 2. 2000 Volt for 480Volt, 3phase, 3wire 3. 1500 Volt for 120/208Volt, 3phase, 4wire 4. 1500 Volt for 208Volt, 3phase, 3wire 5. 1500 Volt for 120/240Volt, 3phase, 4wire 6. 1800Volt for 240v 3phase, 3wire 2.4 SWITCHGEAR, MOTOR CONTROL CENTERS, SWITCHBOARDS AND DISTRIBUTION PANELBOARDS AC FILTER-PROTECTOR A. Provide Waveform Corrector that meets IEEE C62.41.1 and IEEE C62.41.2 Location in accordance with Category B or C. dissipation and filtering circuits. SPD devices incorporating MOV, SAD, gas tube, and/or Selenium technology solely are expressly prohibited as to maintain safety ground integrity. C. Due to sensitivity of electronic based devices and negative effects of high frequency noise on an electrical system, Waveform Corrector must be installed and it must filter noise from 2.5 khz to 2.5 MHz with greater than -30 db filtering across the total simply shunt to ground shall be expressly prohibited D. Waveform Corrector should not only provide low impedance between phase and neutral, but physically convert the electrical energy (noise) and voltage surges to heat, E. Waveform Corrector housing shall be in an enclosure that has the same NEMA rating or higher as the equipment it protects. F. Waveform Correctors shall be installed EXTERNAL to Switchgear or in an explosion and vapor proof separate enclosure inside the gear. Waveform Corrector enclosure does not count as an explosion and vapor proof enclosure. G. UL 1449 maximum suppression voltage shall not be more than:

1. 1500 Volt for 277/480 Volt, 3phase, 4wire 2. 2000 Volt for 480Volt, 3phase, 3wire 3. 1500 Volt for 120/208Volt, 3phase, 4wire 4. 1500 Volt for 208Volt, 3phase, 3wire 5. 1500 Volt for 120/240Volt, 3phase, 4wire 6. 1800 Volt for 240Volt, 3phase, 3wire. MASTER For safety, the Waveform Correctors shall be installed EXTERNAL to any MCC, switchboards, and/or panel boards, unless installed in an explosion and vapor proof enclosure inside the gear. Waveform Corrector enclosure does not count as an explosion and vapor proof enclosure. I. Surge current capacity shall be not less than the following: 1. L-L Capacity: 160 ka/mode 2. L-N Capacity: 160 ka/mode J. Waveform Corrector housing shall be in an enclosure that has the same NEMA rating or higher, as the equipment it protects. 2.5 PANELBOARD AC FILTER-PROTECTOR GREATER THAN 300 AMPERES A. Provide Waveform Corrector meeting IEEE C62.41.1 and IEEE C62.41.2 Location Category A/B. dissipation and filtering circuits. SPD devices incorporating MOV, SAD, gas tube, and/or Selenium technology solely are expressly prohibited as to maintain safety ground integrity C. Waveform Corrector should not only provide low impedance between phase and neutral, but physically convert the electrical noise (energy) and voltage surges to heat, D. Due to sensitivity of electronic based devices and negative effects of high frequency noise on an electrical system, Waveform Corrector must be installed and it must filter noise from 2.5 khz to 2.5 MHz with greater than -30 db filtering across the total simply shunt to ground shall be expressly prohibited. E. Surge current capacity shall be not less than the following: 1. L-L Capacity: 80 ka/mode 2. L-N Capacity: 80 ka/mode F. Waveform Corrector shall be in an enclosure that meets the NEMA rating of the panel board, or higher. G. For safety, the Waveform Corrector shall be installed EXTERNAL to panel boards, unless installed in an explosion and vapor proof enclosure inside the panel board. Waveform Corrector enclosure does not count as an explosion and vapor proof enclosure. H. UL 1449 maximum clamp voltage shall not be more than: 1. 1500 Volt for 277/480 Volt, 3phase, 4wire 2. 1800 Volt for 480Volt, 3phase, 3wire 3. 700 Volt for 120/208Volt, 3phase, 4wire 4. 1500 Volt for 208Volt, 3phase, 3wire 5. 700 Volt for 120/240Volt, 3phase, 4wir 6. 1500 Volt for 240Volt, 3phase, 3wire

2.6 PANELBOARD AC FILTER-PROTECTOR LESS THAN 300 AMPERES A. Provide Waveform Corrector meeting IEEE C62.41.1 and IEEE C62.41.2 Location Category A. dissipation and filtering circuits. SPD devices incorporating MOV, SAD, gas tube, and/or Selenium technology solely are expressly prohibited as to maintain safety ground integrity C. Waveform Corrector should not only provide low impedance between phase and neutral, but physically convert the electrical noise (energy) and voltage surges to heat, D. Due to sensitivity of electronic based devices and negative effects of high frequency noise on an electrical system, Waveform Corrector must be installed and it must filter noise from 2.5 khz to 2.5 MHz with greater than -30 db filtering across the total simply shunt to ground shall be expressly prohibited. E. Surge current capacity shall be not less than the following: 1. L-L Capacity: 12.5 ka/mode 2. L-N Capacity: 12.5 ka/mode F. Waveform Corrector shall be in an enclosure that meets the NEMA rating of the panel board, or higher. G. For safety, the Waveform Corrector shall be installed EXTERNAL to panel boards, unless installed in an explosion and vapor proof enclosure inside the panel board. Waveform Corrector enclosure does not count as an explosion and vapor proof enclosure. H. UL 1449 maximum clamp voltage shall not be more than: 1. 1000 Volt for 277/480 Volt, 3phase, 4wire 2. 1800 Volt for 480Volt, 3phase, 3wire 3. 400 Volt for 120/208Volt, 3phase, 4wire 4. 800 Volt for 208Volt, 3phase, 3wire 5. 400 Volt for 120/240Volt, 3phase, 4wir 6. 800 Volt for 240Volt, 3phase, 3wire ANNUNCIATION AC CIRCUITS A. Provide unit or separately mounted LED-type indication lights to show the normal and failed status of each module. B. [Optional] Provide one set normally open and one set normally closed remote alarm contacts, which operate when the unit fails. 2.7 SURGE COUNTER AC CIRCUITS A. [Optional] Provide each Waveform Corrector rated above 80 ka with dual surge counters displaying the number of voltage transients that have occurred on the unit input. The counter shall retain the count through system power outages. One counter shall be resettable while the other registers aggregate lifecycle surge counts.

3 PART 3: EXECUTION MASTER 3.1 INSPECTION: A. Inspect the facility for voltage configurations and panel boards 3.2 APPLICATION REQUIREMENTS A. Install Waveform Correctors as indicated on manufacturer installation instructions and drawings B. For Electronic Equipment Paired Cable Conductors: Install Waveform Correctors at the input and output interface for each cabinet, CEV, or Shelter. 1. Use secondary Waveform Correctors on lines that do not exit the structure. 2. Use primary Waveform Correctors on lines that exit and enter the structure. 3.3 GENERAL INSTALLATION REQUIREMENTS A. Install Waveform Correctors according to manufacturer s recommendations. B. Install Waveform Correctors directly to the cabinet which houses the circuit to be protected so that the Waveform Corrector leads are straight and short, with all conductors laced, running directly to the point of connection within the panel, without loops or bends. If bends are unavoidable, no bend may exceed 90 degrees and bending radius may not be less than 6 inches. C. Connecting wires shall be as short as possible. Connecting wires shall not exceed 24 inches on main service equipment and no longer than 12 inches in length at any other point. D. For field installed leadless filter-protectors, AC conductors shall be the same as specified for building wire, not smaller than No. 8 AWG and not larger than No.1 AWG. Device leads shall not be longer than the length recommended by the manufacturer, unless specifically reviewed and approved by the manufacturer. E. Provide dedicated disconnecting means for AC Waveform Corrector devices installed at panel boards. Provide dedicated 15-30 ampere circuit breakers (size dependent upon cable size used) with number of poles as required, as disconnecting means for Waveform Corrector devices installed for panel boards, and outside plant applications. The interrupting capacity of the circuit breakers shall be that specified for the other breakers at that location. F. Main service entrance, switchgear, MCC and distribution panel rated 800A do not require dedicated circuit breaker. END OF SECTION