Transformer Trainer. Electrical Power Systems PSL20. Learning Outcomes. Key Features. Key Specifications

Similar documents
Power systems 2: Transformation

ELECTRICAL POWER TRANSMISSION TRAINER

148 Electric Machines

EEE3441 Electrical Machines Department of Electrical Engineering. Lecture. Basic Operating Principles of Transformers

HPS Universal BUCK-BOOST TRANSFORMERS

IVE(TY) Department of Engineering. Electrical Machines 1. Electrical Machines 1. Hour 13. slide 1

~=E.i!=h. Pre-certification Transformers

ECP HV METERING EQUIPMENT COMMISSIONING PROCEDURE

ISOLATING TRANSFORMERS FOR TLC PLANTS

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

ELECTRICAL POWER ENGINEERING

2kVA EARTH TESTING CURRENT INJECTION SYSTEM 4046 / 4047 DATASHEET REDPHASE INSTRUMENTS

Tap Changer Analyzer & Winding Ohmmeter RMO60TD

Industrial Electrician Level 3

N. TEST TEST DESCRIPTION

N. TEST TEST DESCRIPTION

Capstone Turbine Corporation Nordhoff Street Chatsworth CA USA Phone: (818) Fax: (818) Web:

OPTIMIZING MAINS IMPEDANCE: REAL WORLD EXAMPLES by Judith M. Russell Consulting Electrical Engineer PowerLines

OPEN-PHASE DETECTION TECHNIQUES FOR CRITICAL STANDBY SUPPLIES

KENYA ELECTRICITY GENERATING COMPANY LTD

Enhanced Quality with a Touch of Style

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

Transformer Protection Principles

Tap Changer Analyzer & Winding Ohmmeter RMO25TD

MV network design & devices selection EXERCISE BOOK

Winding Ohmmeter & Tap Changer Test Set RMO40TD with Demagnetizer

86 chapter 2 Transformers

Electrical Description

ELECTRICIAN S THEORY EXAMINATION 20 November 2010 QUESTION AND ANSWER BOOKLET

Short Circuit Current Calculations

Three-phase short-circuit current (Isc) calculation at any point within a LV installation using impedance method

Low Voltage Products. Third Harmonic Filter THF and THF star System components for assembly and retrofitting. Catalogue THFS2GB 03_05 1SCC330004C0201

VI 3 - i TABLE OF CONTENTS

Numbering System for Protective Devices, Control and Indication Devices for Power Systems

Hours / 100 Marks Seat No.

POWER SYSTEM ANALYSIS TADP 641 SETTING OF OVERCURRENT RELAYS

BUCK-BOOST TRANSFORMERS

Power Processor - Series 700F 10KVA to 150KVA

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

Bus Protection Fundamentals

Chapter 7 Conclusion 7.1 General

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS. IR Values are to be read on the megger by meggering the Power transformer

Advanced Test Equipment Rentals ATEC (2832) CP RC. Resonance circuit for GIS testing

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

Course 11 Distribution Transformer Applications Instructor: David R. Smith, PE Due: April 24, 2017 (EV), April 25, 2017 (LC)

Specialists in HV and MV test and diagnostics. Testing in Substations

ELECTRICIAN S THEORY EXAMINATION 19 November 2016 QUESTION AND ANSWER BOOKLET

TOSHIBA International Corp

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

Hours / 100 Marks Seat No.

Distribution Transformer Trainer

ET 51 - Electrician Theory Examination Marking Schedule

Company Directive STANDARD TECHNIQUE: TP6F/1. Power Measurement Conventions

Low Voltage Products. Enclosed Third Harmonic Filter THF and THF star Enclosed units. Brochure THFS1GB 03_04 1SCC330003C0201

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

Voltage Relays. Ensuring Reliable Protection for Electrical Systems against Voltage Faults. ISO 9001:2008 Certified.

CONTENTS. 1. Introduction Generating Stations 9 40

ULTRA-K Series 600K - he

MONITORING OF DISTRIBUTION TRANSFORMER PARAMETERS USING PLC

TRAX Transformer and Substation Test System

K Factor Power Transformers

Warehouse Stock Transformers

MODEL 421 Over/Under Motor Load Monitor

EASUN REYROLLE LIMITED

TRAX Transformer and Substation Test System

Three-Phase Transformer Demagnetizer DEM60

DIFFERENTIAL PROTECTION METHODOLOGY FOR ARBITRARY THREE-PHASE POWER TRANSFORMERS

SPAD 346 C Stabilized differential relay

HITEK POWER OL1K SERIES

Description & Applications Questions & Answers Selection Charts Single Phase Selection Charts Three Phase...

Protection of Electrical Networks. Christophe Prévé

Types CDG 11 and CDG 16 Inverse Time Overcurrent and Earth Fault Relay

ELECTRICIAN S THEORY EXAMINATION 15 November 2014 QUESTION AND ANSWER BOOKLET

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad ELECTRICAL AND ELECTRONICS ENGINEERING

Specifications. S&C BankGuard Plus Controls. For Substation Capacitor Banks and Shunt Reactors. Conditions of Sale

1000Vac distribution system for Signalling System applications

FDM Medium Voltage Controller

ME 269 Laboratory Session #5

STS Fully automatic. Large graphic display. Primary injection testing capabilities: up to 3000 A, with the optional module BUX 3000

PRODUCT SPECIFICATION FOR A 15 AND 75 kva, THREE PHASE MODULAR POWER DISTRIBUTION SYSTEM WITH REGULATION AND CONDITIONING (Varian)

Electrical Machines I : Transformers

Transformer Fault Categories

200ADM-P. Current Injection System with Phase Shift A 3.000s 2.000A 50.00Hz 0.0. Features

1 INTRODUCTION ORDER CODE / INFORMATION

Impact Assessment Generator Form

Tertiary Winding Design in wye-wye Connected Transformers Restricted Siemens Energy 2013 All rights reserved.

Powered by technology...driven by service CURRENT TRANSFORMERS. Multifunction Meters. Transducers & Isolators. Temperature Controllers

Module 7. Transformer. Version 2 EE IIT, Kharagpur

Magtech Voltage Booster MVB

INSTRUCTION MANUAL FOR EIDS/S POWER SUPPLY

Electrical Switchgear & Power Transformer Testing. H.H. Sheik Sultan Tower (0) Floor Corniche Street Abu Dhabi U.A.E

Multi Differential Relay, MDR-2 DESCRIPTION OF OPTIONS

HV / MV / LV electrical network quality analyzers Class A. Communication port: local, modem, integrated Ethernet, multi-point

Course No: 1 13 (3 Days) FAULT CURRENT CALCULATION & RELAY SETTING & RELAY CO-ORDINATION. Course Content

Methods of secondary short circuit current control in single phase transformers

Cornerstone Electronics Technology and Robotics Week 32 Transformers

HITEK POWER OL3000 SERIES

Transformer & Induction M/C

500 kva Dry-type Isolation Transformer V-Delta to 208Y/120V 3PH - NEMA 1/Indoor

Magtech Voltage Booster MVB

Transcription:

Electrical Power Systems PSL2 Investigates the principles and operating characteristics of single-phase and three-phase power and distribution transformers Key Features Educational transformers with fully accessible and unique one-volt-per-turn primary, secondary and tertiary windings Built-in industrial-standard digital protection relay gives wide range of functions module also includes an extra socket for additional relays to give more experiments Separate single and three-phase educational transformers, with an additional delta-star transformer Includes supplies, circuit protection, internal load banks, instruments and controls Thermocouples included in transformer windings for thermal tests Learning Outcomes Voltage and turns ratios Parallel and series windings, delta, star and interstar Open and short circuit tests to find transformer properties, including losses and efficiency Balanced and unbalanced loads Phase differences in popular three phase transformer connections Three to two-phase connections (Scott and Le Blanc) Key Specifications Three single-phase transformers One three-phase transformer Resistive, inductive and capacitive loads Fixed ratio delta-star transformer Overcurrent protection relay Page of 5

PSL2 Description The module fully examines singlephase and three-phase power and distribution transformers. The fully instrumented unit includes: One three-phase educational transformer Three single-phase educational transformers with tertiary windings One three-phase delta-star transformer All windings of the educational transformers connect to colour-coded shrouded sockets on the control panel. The educational transformers work at one volt each turn, so the no-load output voltages are the same as the number of secondary turns. An adjustable autotransformer allows lower voltage experiments (for example - with the educational transformers). The module includes a second fixed ratio delta-star transformer for extra experiments. The control panel includes all the analogue and digital meters and transducers needed to measure electrical voltage, current and power for all transformer tests. Also included are selectable resistive, inductive and capacitive loads, which can connect in parallel, series, delta or star connection. Thermocouples are fixed to one set of windings and core of the three-phase educational transformer. They are also fixed to one of the single-phase educational transformers. The thermocouples connect to a digital temperature indicator to provide direct readings of core and winding temperatures. For protection tests, the three-phase circuits include current transformers to link to an industrial standard protection relay. The user connects and sets the protection relay to detect line and earth currents, voltage and frequency faults. The relay also monitors and measures fault events and disturbances for fault analysis. The user sets the relay from its local control panel or by a cable link to a suitable computer (computer not included) and software (included). When the user applies a circuit fault, the relay opens circuit-breakers in the test circuits. The circuit-breakers also include hand-operated switches, and lamps. The lamps show whether the circuit-breakers are open or closed. An extra socket on the equipment supplies power and control for any optional relays (available separately) for use with the module, for example TecQuipment s Differential Protection Relay (PSA5). Supplied with the equipment is a set of shrouded leads for the user to connect the test circuits together. The unit includes an emergency switch, a mains supply isolator and protection fuses. Other possible experiments (not detailed in TecQuipment s manuals) Core and winding temperatures in a three phase transformer (thermal tests) The effect of core-type construction in a three-phase transformer Differential protection of a delta-star connected transformer, when used with the Differential Protection Relay (PSA5) Analogue Meters Delta-star Transformer Protection relay Loads Three-Phase Transformer Single-Phase Transformers Page 2 of 5

supply PSL2 3-PHASE -PHASE (L TO L2) 3-PHASE -PHASE (L TO L2) DIGITAL TEMPERATURE INDICATOR - TX3 - HV WINDING 2 - TX3 - CORE 3 - TX3 - LV WINDING 4 - TX6 - HV WINDING 5 - TX6 - CORE 6 - TX6 - LV WINDING Degrees PHASE PHASE ANGLE 6--6 V V 2 OFF ON V TX / 22V Dy TP PROTECTION CT TP 2 TP 3 PROTECTION CT TP 4 PROTECTION CT TP 5 a b RATIO 7/ a b RATIO 7/ TX2 a b RATIO 4/ 22/22V Dy -24V N N N VARIABLE FIXED CB CB2 CB3 Main circuits (schematic) 87 mm 85 mm Standard Features Supplied with comprehensive user guide Five-year warranty Manufactured in accordance with the latest European Union directives ISO9 certified manufacturer Recommended Ancillaries Oscilloscope (OS2) Differential Protection Relay (PSA5) Page 3 of 5

PSL2 Typical Work Assignments Short Circuit Tests This test measures the losses due to the copper windings in the single phase transformers, and produces charts of voltage and power against current. Short Circuit Test 6 Applied Voltage (Vsc) 5 Short Circuit Current (Isc) Single Phase Transformer Yy6 Connection This test connects one of the single phase transformers in the Yy6 connection and measures the input and output voltages to b 6.93 VAC yn a c 2 VAC A7 2.79 VAC 24 VAC YN 3.86 VAC C7 B7 Page 4 of 5

PSL2 Detailed Specifications TecQuipment is committed to a programme of continuous improvement; hence we reserve the right to alter the design and product specification without prior notice. Nett dimensions and weight: 85 mm long x 87 mm high x 96 mm front to back and 79 kg Approximate packed volume and weight: 5 m 3 and 95 kg Delta-star transformer: 5 kva 22/22 VAC three-phase delta to star (Dy) Single-phase educational transformers: Three x one volt per turn transformers rated at kva and 24 V with multi-tapped primary, secondary and tertiary windings. One transformer has thermocouples to its windings and core. Three-phase educational transformers: 3 kva nominal ( kva each phase) three-limb three-phase transformer with multi-tapped primary and secondary windings. One phase has thermocouples to its windings and core. Instruments: Single and three-phase multi-function meters for a.c. measurements (voltage, current, and power) Phase angle meter Thermocouple temperature indicator Analogue voltage, current and power meters Voltage and current transducers Protection relay: Overcurrent protection relay Essential Services Electrical supply: Three-phase 5 kva, 5 Hz or 6 Hz (specify on order) 5 Hz needs 38-44 VAC 6 Hz needs 2-24 VAC Floor space needed: Approximately 3 m x 2 m of solid, level floor Operating Conditions Operating environment: Laboratory environment Storage temperature range: 25 C to +55 C (when packed for transport) Operating temperature range: +5 C to +4 C Operating relative humidity range: 8% at temperatures < 3 C decreasing linearly to 5% at 4 C Sound Levels Less than 7 db(a) Page 5 of 5