Similar documents
2001A. 200KHz Function Generator Instruction Manual. 99 Washington Street Melrose, MA Phone Toll Free

PB-500. Analog Circuits Trainer Instruction Manual

Model 7000 Low Noise Differential Preamplifier

INSTRUCTION MANUAL LKG 601 Electrical Safety Analyzer

INSTRUCTION MANUAL LKG

POWER SUPPLY MODEL XP-720. Instruction Manual ELENCO

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

Model 229 Series 2 Leakage Current Tester OPERATOR S MANUAL

Warning, refer to accompanying documents.

Instruction Manual Model M Switch, DPDT, Manual Select

Angular Rate Sensor. Owner's Manual

Safety. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.

Model 3210C. 100 Ampere AC Current Standard. Operating Manual

User s Guide. MultiView Series Digital MultiMeters Models: MV110 MV120 MV130

TRANSFORMER TEST SYSTEM MODEL NUMBER TTS2.5 VERSION 1.1

Model MV106J/MV116J. ±10nVdc to ±11Vdc Precision DC Voltage Standard Source. Operating Manual

WRM-10 TM TRANSFORMER WINDING RESISTANCE METER

INSTALLATION AND MAINTENANCE MANUAL FOR GROUND MONITOR GM-250 COPYRIGHT 1983 AMERICAN MINE RESEARCH, INC.

Handheld Digital Multimeter PRO-50A

TRIAXIAL FLUXGATE MAGNETOMETER OWNER'S MANUAL

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

Broadband Step-Up Transformer. User Manual

DC200A Displacement Clipper User Manual

PARALLEL MULTI-AMP KIT for 7200 Series AMPLIFIERS INSTRUCTION SHEET

Model 1791 VHF Radio User's Manual

Model 4007DDS. 7 MHz Sweep Function Generator

DM-46 Instruction Manual

200Amp AC Clamp Meter + NCV Model MA250

Series 3000 Model R-107A

Harris IRT Enterprises Multi-Channel Digital Resistance Tester Model XR

BC145 SIGNAL ISOLATOR BOARD

Model 935A. Dual Tone Sender INSTRUCTION MANUAL

INSTRUCTION MANUAL For LINE IMPEDANCE STABILIZATION NETWORK. Model LI khz to 10 MHz

HTA125A/250A. Power Amplifiers. Installation & Use Manual

INSTRUCTION MANUAL MODEL 4010A. 2 MHz FUNCTION GENERATOR MANUAL DE INSTRUCCIONES MODELO 4010A. 2MHz GENERADOR DE FUNCIONES

34134A AC/DC DMM Current Probe. User s Guide. Publication number April 2009

INSTRUCTIONS PS2500 POWER SUPPLY

SPM-50 RF Spectrum Power Meter PC Software User Manual

201AP Charge Amplifier User Manual

P5100A & P5150 High Voltage Probes Performance Verification and Adjustments

Pen Multimeter. Model

An American Control Electronics Brand PCM4 SERIES USER MANUAL PCM4.

2015 RIGOL TECHNOLOGIES, INC.

Distribution Amplifiers 1

Keysight 16440A SMU/Pulse Generator Selector

DDS Function Generator

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

DM-46 Instruction Manual

CD770 DIGITAL MULTIMETER INSTRUCTION MANUAL

HydroLynx Systems, Inc.

User s Guide. 400A AC/DC Clamp Meter. Model MA220

Amplifier Series BASIC. Installation & Operations Manual

41P Portable Calibrator User Manual

AMERITRON RCS-12 AUTOMATIC ANTENNA SWITCH

INSTRUCTION MANUAL FOR EIDS/S POWER SUPPLY

R-F Skewed Hybrids. Type H1SB and H1SB-R. & R-F Balanced Hybrids Type H1R, H3X and Type H1RB, H3XB and Type H1RB-40. System Manual CH44 VER03

DANFYSIK A/S - DK-4040 JYLLINGE - DENMARK

USER MANUAL MODEL Parallel to Serial/ Serial to Parallel Interface Converter

Advanced Test Equipment Rentals ATEC (2832)

AMP SELECTOR Owner s Manual

PCO-7114 Laser Diode Driver Module Operation Manual

200B Clipper Module User Manual

KeyPre KP6 - Electronic Instrument Preamplifier

7I25 H-BRIDGE MANUAL

BLD75-1. Bilevel Step Motor Driver. User s Guide. #L010125

EXECUTE Shiloh Road Alpharetta, Georgia (770) FAX (770) Toll Free

O. S. WALKER MICROPROCESSOR CHUCK CONTROL MODEL MSB SERIES TABLE OF CONTENTS

45EMD Portable Calibrator User Manual

INSTALLATION AND OPERATING INSTRUCTIONS MODEL SIVF. KB Part No Signal Isolator for KBVF Controls. See Page 1 Pending

AMP-12 OPERATOR S MANUAL

Warning, refer to accompanying documents V CAT II Overvoltage category II device. CSA Canadian Standards Association

USER MANUAL. Maxwell Technologies BOOSTCAP Energy Storage Modules. User Manual for 15V Modules: 20 F, 23 F, 53 F, 58 F 15 Volts DC

P5100A & P5150 High Voltage Probes Performance Verification and Adjustments

ALS. Advanced Test Equipment Rentals ATEC (2832) FOR SERVICE CALL ADVANCED TEST EQUIPMENT SERVICE

Model 228 Current Leakage Tester INSTRUCTION MANUAL

CMP-300 Composite Mixer/ Distribution Amplifier

OPERATOR S MANUAL Model 160 Volt-Ohm-Milliammeter

Operator s Manual. PP016 Passive Probe

Copyright 2014 by Minarik Drives

VT1586A Rack Mount Terminal Panel Installation and User s Manual

MODEL W Power Amplifier

Model 1737 Dual Range DC Power Supply

Glass Electrode Meter

PA WATT PORTABLE PA SYSTEM PRODUCT MANUAL

TEGAM, INC. SINGLE/DUAL CHANNEL HIGH VOLTAGE AMPLIFIER MODEL 2340/2350. Instruction Manual PN# CD Publication Date: June 2006 REV.

DCS-E 1kW Series DC Power Supplies

FarmPS-1 Table of Contents

INSTRUCTION MANUAL. March 11, 2003, Revision 3

Digital Lighting Systems, Inc.

User s Guide. Agilent 16441A R-Box. Agilent Part No Printed in Japan January Edition 4

DIGITAL / ANALOG TRAINER

WireMaster Coax BNC PN: Rev C 2/13

Type Contact form Plug-in/solder Plug-in/solder PCB terminals Upper-mounting terminals terminals with plug-in/solder

Instruction Manual. Model 1856D 3.7GHz Frequency Counter

Model 935A Current Source Operation Manual

PB-503 DESKTOP ANALOG & DIGITAL DESIGN TRAINER. User Manual

Oberebenestrasse Bremgarten Switzerland Tel Fax

Autoranging Multimeter Extech EX503

Model 1792 VHF Radio. User s Manual. Rev. B FAA APPROVED NOT FAA APPROVED. ECP Dec 30

TABLE OF CONTENTS. 1) Introduction 2. 2) Unpacking your preamplifier 2. 3) Installing the preamp into your system 3

Transcription:

1506 Isolated Variable AC Line Supply Instruction Manual 10/2011

TABLE OF CONTENTS SECTION DESCRIPTION PAGE NO. 1 INTRODUCTION 1 2 SPECIFICATIONS 2 3 DESCRIPTION 3 4 OPERATING INSTRUCTIONS 5 5 SERVICE & 6 WARRANTY INFORMATION 6 CALIBRATION PROCEDURE 9 7 PART LIST & SCHEMATICS 11 8 CIRCUIT DIAGRAM 15

SECTION - 1 INTRODUCTION ISOLATED VARIABLE AC LINE SUPPLY : MODEL1506 The 1506 Isolated Variable AC Source cum leakage current tester is designed for modern electronics laboratories needing a clean, electrostatically and galvanically isolated variable line supply. The unit is designed to provide isolated output variable from 0 to 130 V AC at 4 Amps max and 0 to 260VAC at 2A max on two seperate output sockets through a range selector switch.the output voltage and load current can be monitored on a 3 digit DPM. The variable isolated output voltage capability makes this unit very convenient to use for either incoming or outgoing quality control testing. It is also useful for servicing or circuit design work, when checking operation at voltage higher or lower than normal. The unit consists of a super isolation transformer which is triple shielded from the line to protect against shock hazards. The 1506 can measure power line leakage current by means of a probe and a switch selected range of the output DPM. It can measure leakage currents upto 9.99 ma.the unit is overload protected by means of an input /output fuse. INITIAL INSPECTION Before shipping, the 1506 power supply has been tested thoroughly and found free of mechanical and electrical defects. As soon as it is unpacked, inspect for any damage that may have occurred during transit. Particular attention should be paid to the meters. Also check the packing material for any signs of severe stress (may be indicative of internal damage). Save all the packing material. Read the INSTRUCTION MANUAL carefully prior to operation. PCB Components FRONT PANEL Reference Designator Part Description = OUTPUT SOCKETS SOCKET 1 European ( 230VAC ) SOCKET 2 American ( 115VAC ) SOCKET 3 SLBR4 ( Lekage Red ) SWITCHES SW1 SW2 FUSE F1 F2 ON/OFF SPDT 1801 10A/230V DPDT Toggle 6A/250V 6Amp / 250V S/B 4AMP / 250V S/B FUSE HOLDERS FH1 10Amp / 250V R3-11 FH2 10AMP / 250V R3-11 PCB Components CHASSIS Reference Designator Part Description = TRANSFORMERS T1 T2 T3 T4 T5 1506 Isolation 1506 Current 1506 DPM 1506 0-120V/4Amp Variable 1506 Voltage Sense 1 14

PCB Components 0893 DPM Reference Designator Part Description = CAPACITORS C1 220pf 100V ±20% CD C2 0.1µf 100V ±10% MP C3 0.01µf 100V ±20% CD C4 0.47µf, 100V ±20% CD C5 0.1µf, 50V ±10% MP C6 10µf, 35V ±20% EL C7 0.1µf, 50V ±10% MP C8 0.1µf, 50V ±20% CD C9 Not used C10 470µf, 35V ±20% EL C11 2.2µf, 50V ±20% EL * C12 47µf 50V, ±20% EL ( Additional ) * C13 0.1µf 50V, ±20% CD ( Additional ) DIODES D1 D2 D3 TO D6 TRANSISTORS/FET S Q1 Q2 Q3 IC IC1 1N4148 1N4148 1N4007 TL431 MPSA12 LM7805 ICL 7107 CPL FND S DS1 TSD566 ( Green ) DS2 TSD566 ( Green ) DS3 TSD566 ( Green ) LED S LED1 LED2 3mm GREEN Defused 3mm GREEN Defused CONNECTORS CON1 3 PIN 2.54 PITCH ( Male / Female ) CON2 ( L' Type ) 7 PIN 2.54 PITCH ( Male / Female ) 13 INPUT VOLTAGE INPUT FREQUENCY OUTPUT METERING METER ACCURACY OUTPUT-LINE ISOLATION NOISE REJECTION SECTION - 2 SPECIFICATIONS : 230V AC : 47 to 63 Hz. : I : 0 to 130 VAC at 4AMP Max. ( Available on American socket only. ) II : 0 to 260 VAC at 2AMP Max. ( Available on European socket only. ) : 3 digit DPM to read 1) Output Voltage. 2) Load Current and 3) Leakage current upto 9.99 ma. : ± 3 counts. : Capacitive coupling less than 0.0005 pf. : Better than 120 db ( common mode noise ). DIMENSIONS (W x H x D ) : 11.73" x 5.23" x 10.62" WEIGHT : 35 lb. approx. 2

SECTION - 3 DESCRIPTION INPUT AND OUTPUT TERMINATION : The unit works from 230VAC, 47-63 Hz single phase supply with internal tap selection facility for 115V AC operation. The input is provided through a mains cable with a plug. The use of a three core cable enables the cabinet of the unit to be properly grounded. The unit as shipped from factory is wired for 230V /50Hz single phase supply Output is provided on two seperate sockets through a output voltage range selector switch. In one position, it provides 0-130 VAC at 4 Amps max whereas in other position,it provides 0-260VAC at 2Amp.max. METERING : One 3-digit DPM is provided to measure 1) Output voltage 2) Leakage current 3) Load current Meter function is switch selectable ON-OFF SWITCH AND FUSE : The power ON-OFF switch is located on the front panel. The fuses (Input & Output) are also located on the front panel. The fuse ratings are clearly marked. PANEL CONTROLS : A voltage adjust knob allows adjustment of output AC voltage and the output voltage selector switch selects the output AC voltage range so as to provide 0-130VAC isolated output only on American socket while 0-260VAC isolated output only on European socket. Three meter function push switches are provided to select the Leakage Current or Output Voltage or Output Current (ma,v & A respectively.) to be displayed on the meter. PCB Components GLOBAL 1505 / 06 SW - 0396 Reference Designator Part Description IC S IC1 7660 S IC2 KA 741/ LM 741 PUSH SWITCHES SW1 TO SW3 4 Pole, 2 Way ( Interlock ) RELAY RL1 2/P 2CO 6V/6A ( OEN 58-06-2C ) CONNECTORS CON1 5 PIN 2.54 PITCH ( MALE / FEMALE ) CON2 7 PIN 2.54 PITCH ( MALE / FEMALE ) PCB Components 0893 DPM Reference Designator Part Description RESISTORS R1 39K, ¼W, ±5%, MFR R2 470K, ¼W, ±5%, MFR R3 1ME, ¼W, ±5%, MFR R4 SEL, ¼W, ±5%, MFR R5 2.4K, ¼W, ±5%, MFR R6 2.7K, ¼W, ±5%, MFR R7 30K, ¼W, ±5%, MFR R8 8.2K, ¼W, ±5%, MFR R9 100E, ¼W, ±5%, MFR R10 12K, ¼W, ±5%, MFR R11 20K, ¼W, ±5%, MFR R12 100E, ¼W, ±5%, MFR R13 330E, ¼W, ±5%, MFR R14 Not in Use PRESETS PR1 2.2K Horizontal 3 12

SECTION - 7 PART LIST PCB Components GLOBAL 1505 / 06 SW - 0396 Reference Designator Part Description RESISTORS R1 R2 R3 R4 R5 R6 R7 R8 R9 R10 R11 R12 R13 R15 1.5K, ¼W ±5% MFR 120E, ¼W ±5% MFR 10K, ¼W ±5% MFR 62K, ¼W ±5% MFR 10 ohm, ¼W ±5% MFR 220 ohm, ¼W ±5% MFR Not Used 10K, ¼W ±5% MFR 100K, ¼W ±5% MFR 10M, ¼W ±5% MFR 4.7K, ¼W ±5% MFR 10K, ¼W ±5% MFR 1.2M, ¼W ±5% MFR 470K, ¼W ±5% MFR CIRCUIT DESCRIPTION : The circuit uses a step down tranformer to provide step down supply to a single phase variable autotransformer to obtain an output voltage variable from 0 to 130VAC. This is followed by a triple shielded isolation transformer which provides an output voltage from 0-130VAC or 0-260VAC electrostatic and galvanic isolation. Multiple shielding technique reduces primary to secondary static coupling to below 0.0005pF. The DC isolation is over 1000 M Ohms. CAPACITORS C1 C2 C3 C4 C5 C6 1µf, 50V ±20%, ELEC 1µf, 50V ±20%, ELEC 220µf, 16V ±20%, ELEC 220µf, 50V ±20%, ELEC 0.1µf, 100V ±10%, MP 0.22µf, 100V ±10%, MP PRESETS PR1 100E Horizontal PR2 100E Horizontal PR3 100E Horizontal PR4 10K Horizontal DIODES CR1 CR2 CR1 1N4007 1N4148 1N4148 11 4

SECTION - 4 OPERATING INSTRUCTIONS a) 1506 as Isolated Variable AC Supply. Set output voltage to 0 volt by turning the 'Set Voltage' knob to minimum position. Press push button switch marked 'V' Keep the output voltage selector switch to the desired range (0-130V or 0-260V). Isolated variable voltage will be available at the respective output socket only. Switch "POWER"ON. Adjust the voltage control knob till the desired voltage is indicated on the 3-digit DPM.Connect the load at the output. Press push switch marked 'A'.The DPM will now read the load current. The total load current should not exceed the maximum rating indicated for each range. LEAKAGE CURRENT CALIBRATION 9) Set output voltage to zero volt s by turning the Voltage knob to minimum position. 10) Press push switch marked ' V ' 11) Switch on the power.adjust output voltage to 130VAC. 12) Press push switch marked ' ma '. now DPM will read leakage current. 13) Connect 25 Kohm (aprox.1w) resistor across banana socket,marked 'LEAKAGE TEST', & live point of output socket. Adjust preset PR1on switch pcb so that DPM reading is 5.00mA b) 1506 as Line Leakage Tester. Set output voltage to 0 volt by turning the knob to minimum position. Press push switch marked V. switch "POWER" ON. Adjust the voltage control till the desired voltage at which leakage current is to be measured is available at the output socket. Now press push switch marked ma. Connect unit under test (U. U. T) to output socket. Connect the leakage test probe at the socket marked 'Leakage Test'. Connect the other end of the leakage test probe to the chassis of the unit under test. Depending on the leakage,the DPM will read the leakage current. 5 10

SECTION - 6 CALIBRATION PROCEDURE FOR MODEL 1506 1) Keep the Voltage knob to minimum position(ccw). Press push switch marked ' V ' 2) Switch on the power. 3) Set reference voltage of DPM(pin no. 36 of U1-7107) to 1.00Volt by adjusting the preset VR1 on DPM pcb. 4) Set voltage at pin no. 6 of IC3 (CA3160) to zero Volts with the help of preset PR4 on switch pcb. VOLTAGE CALIBRATION 5) Set desired output voltage by turning Voltage knob in clockwise direction.connect external AC voltmeter at the output. 6) Adjust preset PR2 on switch pcb so that DPM reading matches with external AC Voltmeter. CURRENT CALIBRATION 7) Press push switch marked ' A '. Connect load at the output with AC current meter in series with the load.the DPM will now read the load current.(the load current should not exceed 2 Amps/4Amps for Range A/B respectively.) 8) Adjust preset PR3 on switch pcb so that the DPM reading matches with external AC current meter SECTION - 5 SERVICE AND WARRANTY INFORMATION FACTORY SERVICE AND REPAIR Global Specialties will service and repair this instrument free of charge for a period of one full year, subject to the warranty conditions stated below. To obtain a return merchandise authorisation (RMA) required for all returns, phone our Customer Service Department for a RMA and all shipping instructions : GLOBAL SPECIALTIES 22820 Savi Ranch Parkway, Yorba linda, CA 92887, WWW.globalspecialities.com 800-572-1028 WARRANTY Global Specialties warrants this device to be free from defective material or workmanship for a period of one full year from the date of original purchase. Global Specialties under this warranty is limited to repairing the defective device when returned to the factory, shipping charges prepaid, within one full year from the date of original purchase. Units returned to Global Specialities that have been subject to abuse, misuse damage or accident, or have been connected, installed or adjusted contrary to the instructions furnished by Global Specialities, or that have been repaired by unauthorized persons will not be covered by this warranty. Global Specialities reserves the right to discontinue models, change specifications price or design of this device at any time without incurring any obligation whatsoever. 9 6

The purchaser agrees to assume all liabilities for any damages and/or bodily injury which may result from the use or misuse of this device by the purchaser, his employees or agents. This warranty is in lieu of all other representations or warranties expressed or implied and no agent or representative of Global Specialties is authorized to assume any other obligation in connection with the sale and purchase of this device. Specifications subject to change without notice. Copyright 1994, INTERPLEX ELECTRONICS, INC, Unit No.2, Highland Industrial Centre 1486, Highland Avenue, Cheshire CT 06410, U.S.A. and TM trademarks are the property of INTERPLEX ELECTRONICS, INC, Unit No.2, Highland Industrial Centre 1486, Highland Avenue, Cheshire CT 06410, U.S.A. MAINTENANCE AND RECALIBRATION ADJUSTMENTS All circutry is factory-calibrated. No user adjustments are required. FUSE REPLACEMENT Remove the line cord from the AC outlet before changing fuses. Using a screwdriver, remove the fuse holder cap. Replace the fuse with another fuse of identical type and current rating. Replace the fuse holder cap. CASE DISASSEMBLY AND ASSEMBLY WARNING Potentially lethal AC power is present whenever the line cord is plugged into the AC outlet, even when the power switch is OFF. Always disconnect the power cord when opening the case. Avoid touching the fuse post on the inside of the unit. Should access to the inside of the unit be required, proceed a follows: 1. Remove the line cord from the AC outlet before disassembly. 2. To disassemble the case, remove the screws that secure the cover to the chassis and lift the cover off. 3. To reassemble the case, place the cover on the chassis, line up the screw holes, and replace the screws. 7 8

SERVICE AND WARRANTY INFORMATION For up-to-date product information, please visit www.globalspecialties.com. For instructions on how to obtain a return merchandise authorization number (RMA), please visit our website, or call our customer service department. GLOBAL SPECIALTIES 22820 Savi Ranch Parkway Yorba Linda, CA 92887 800-572-1028 globalspecialties.com Global Specialties will service and repair this instrument free of charge for a period of 3 full years, subject to the warranty conditions below. WARRANTY Global Specialties warrants the PB-503 to be free from defective material or workmanship for a period of 3 full years from date of original purchase. Under this warranty, Global Specialties is limited to repairing the defective device when returned to the factory, shipping charges prepaid, within 3 full years from date of original purchase. Units returned to Global Specialties that have been subject to abuse, misuse, damage or accident, or have been connected, installed or adjusted contrary to the instructions furnished by Global Specialties, or that have been repaired by unauthorized persons will not be covered by this warranty. Global Specialties reserves the right to discontinue models, change specifications, price or design of this device at any time without notice and without incurring any obligation whatsoever. The purchaser agrees to assume all liabilities for any damages and/or bodily injury which may result from the use or misuse of this device by the purchaser, his employees, or agents. This warranty is in lieu of all other representations or warranties expressed or implied and no agent or representative of Global Specialties is authorized to assume any other obligation in connection with the sale and purchase of this device. All rights reserved. No Part of this book shall be reproduced, stored in a retrieval system, or transmitted by any means, electronic, mechanical, photocopying recording, or otherwise, without written permission from the publisher. No patent liability is assumed with respect to the use of the information contained herein. While every precaution has been taken in the preparation of this book, the publisher assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained herein.