Real-time current profiles and directional waves for intermediate water

Similar documents
Aquadopp Profiler 2 MHz

Mean currents and turbulence, plus wave height, direction and ice tracking

REVOLUTIONIZING LONG RANGE CURRENT PROFILING BROADBAND SERIES TRUE INNOVATION MAKES A DIFFERENCE

The Signature VM package delivers vessel-mounted AD2CP capabilities based on present-day technology

OFFSHORE ENERGY. BUYER S GUIDE HYDROlog Hydrotest Logger Range. Simply advanced

A New Wave Directional Spectrum Measurement Instrument

SeaWATCH ADCP. Self-Contained 300 khz / 600 khz / 1200 khz

Applications. > > Oil & Gas. > > RoVs and auvs. > > Oceanography. > > Monitoring stations. > > Seismic. > > Networks and relay chains

LBL POSITIONING AND COMMUNICATION SYSTEMS PRODUCT INFORMATION GUIDE

UCM-60 / UCM-60DL Technical Description. Revision 1.10

USBL positioning and communication SyStEmS. product information GUidE

em4 local - Robust Specific characteristics Part number

Specifications and Dimensions

Tsunami Detection System Nick Street, Project Engineer David Mould, Presenter.

em4 em4 alert em4 alert 2G

Datalogger DL.OCS/N/RS485

ClampOn, Inc. Ultrasonic Intelligent Sensors. Presented by Hans A. Wagner

100 h; (min. 70 h at 40 C); 200 days (typ.) with optional battery module Memory Number of memory modules (optional)

Gyrocompass and motion sensor. octans. navigation and positioning

DP Operator Course Training Manual HPR

NEW TOUGHEST WIND SENSORS THE WORLD S 1:2

Project Report Liquid Robotics, Inc. Integration and Use of a High-frequency Acoustic Recording Package (HARP) on a Wave Glider

Product type designation. General information. Hardware product version 01. Firmware version V2.6. Engineering with. update.

METEOROLOGICAL INSTRUMENTS

USBL positioning and communication systems. Applications

Datalogger DL.OCS/N/RS485

Picture 1 PC & USB Connection

TD 304 OPERATING MANUAL Doppler Current Profiler Sensor December 2015 DCPS 5400 / 5402 / 5403

SOLVED MEASUREMENT COMMUNICATION INSIGHT

GPRS Inclinometer. Zigbee. CDMA Vibration-wire. SSI PWM Switch Analog. Features. Descriptions

Fluke Three-Phase Power Quality Recorder Topas. Class-A compliance for the most demanding power quality tests

6ES7214-1AG31-0XB0. General information Engineering with. Supply voltage 24 V DC Yes permissible range, upper limit (DC)

Ron 2150 Shackle Type Dynamometer with 2"/50mm Attachable Display

The wireless alternative to expensive cabling...

THE CONNECTED INFRASTRUCTURE SOLUTION MONITORING HOW STRUCTURES EVOLVE

DTM.OCS.S/N - Modbus Level Transmitter

905U Wireless. New Products... New Solutions. The wireless alternative to expensive cabling... Simple but Reliable. Easy to Use

Motion Reference Units

DRTS-6. DRTS-6 has been designed to test: DRTS-6. Advanced Protection Relay Test Set and Measurement System

PRINCIPLE OF SEISMIC SURVEY

AERINOS Profisens - Wireless IoT Platform

Temposonics. Magnetostrictive Linear Position Sensors. ER SSI Data Sheet

11. Lowered Acoustic Doppler Current Profiler (LADCP)

K-Band Doppler Sensor Module

AccuStar Electronic Clinometer

Connecting Mains Electrical Power

Ron 2000 Shackle Type Dynamometer with Remote Indicator

SSI Inclinometer. Zigbee. CDMA Vibration-wire. SSI PWM Switch Analog. Features. Descriptions

Maintenance: Check the measurement signal: regularly required once a month Calibration: typically 6 to 12 months after installation

PD30CNB25xxPS. Photoelectrics, Background suppression reflective - PointSpot. Main features. Main functions. Description

SonoLab Echo-I User Manual

SLX-1 Multi-Application GNSS Receiver

Low Frequency Coherent Source Sonobuoy

Technical specification FLUXUS F401 H2O

Product type designation. General information. Supply voltage

Acterna DSAM Product Family

Appendix B. Argonaut-SL Principles of Operation

SIMATIC S7-1200, CPU 1212C, COMPACT CPU, DC/DC/DC, ONBOARD I/O: 8 DI 24V DC; 6 DO 24 V DC; 2 AI 0-10V DC, POWER SUPPLY: DC

CRD WR_LOG _ WR LOG WIRELESS MONITORING SYSTEM READOUT UNITS AND DATALOGGERS

POSICHRON position sensor in a stainless steel pressure case. Voltage: V, 3 wire Current: ma, 3 wire

2. Measurement Range / Further specifications of the LOG_aLevel system

Motion Reference Units

Production Analyzer Rev (USB + FireWire) Rev. 2.x (USB only)

The wireless alternative to expensive cabling...

DRTS 66 The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

Controller for the Implementation of a Central or Decentralized Electrohydraulic System

The wireless alternative to expensive cabling...

Temposonics. R-Series SSI. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Stroke length mm. Perfect data processing 0.

Hybrid Bi-SectorTM Array

Temposonics. Magnetostrictive Linear Position Sensors. GB-M / GB-T SSI Data Sheet

6ES BE30-0XB0 6ES AE30-0XB0 6ES HE30-0XB0

RY836AI. High Performance GPS & Glonass / GPS & BeiDou Parallel mode antenna module with Compass, Gyroscope, Accelerometer, Pressure Sensor.

A New Long Range Current Profiler Development of the Signature75

DIS-5010A, DIA-512A. Data Acquisition System for Crash Test AUTOMOTIVE TEST EQUIPMENT

Power Quality Analyzer Topas 2000

CRD WR_LOG _ WR LOG WIRELESS MONITORING SYSTEM READOUT UNITS AND DATALOGGERS

Pressure transmitters for high temperature marine applications Type MBS 3300 and MBS 3350

METEOROLOGICAL INSTRUMENTS

Hybrid Bi-SectorTM Array

GLOBALSAT GPS Engine Board

WIRELESS INSULATOR POLLUTION MONITORING SYSTEM

Using new monitoring and control technology to advance safety and asset integrity in the oilfield

CM3-SP04EAO CM3-SP04EAA CM3-SP04EOAI CM3-SP04EOAV

ICAM. Electronics & Software. Industrial Charge Amplifier for Applications in Manufacturing. Type 5073A...

NOVOHALL Rotary Sensor non-contacting. Series RSC2800 digital SSI, SPI, Incremental

Protection Class (IEC 529)

PLC-K506 Series FEATURES DESCRIPTION FEATURES

FIBER EVO. Miniaturized laser module complete with controller and USB power supply all within an incredibly small package

SA-320 Installation Guide SA-320. Installation Guide. Date: Mar, 2011 Version: 2.5. All Rights Reserved

POSICHRON position sensor in stick design. Protection class. Voltage: V, 3 wire Current: ma, 3 wire

Pressure Transmitter Type AKS 32 and AKS 33 REFRIGERATION AND AIR CONDITIONING. Technical leaflet

Agilent Agilent 34405A Multimeter 5.5 Digit Dual Display, Benchtop DMM More Capabilities at a Value Price. Data Sheet

Hybrid Bi-SectorTM Array

Temposonics. R-Series SSI. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Measuring length mm. Perfect data processing I 7 I

Temposonics. Magnetostrictive Linear Position Sensors. EP2 SSI Data Sheet

DS2000ICLA. Specification highlights Symbol Unit Min Typ Max. Features. Applications: 1 ppm linearity. MPS for particles accelerators.

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

INCLINOMETER RS232 SWITCH

IBIS range. GeoRadar Division. GeoRadar Division. Static and Dynamic Monitoring of Civil Engineering Structures by Microwave Interferometry

Transcription:

Real-time current profiles and directional waves for intermediate water The AWAC 600 khz ADCP has become the standard reference technology in submerged wavemeasurement applications. Thousands of these ADCPs have been deployed to capture the full wave spectrum in combination with current profiles. With a 60 m maximum range for wave measurements and 2 Hz sampling of the surface elevation, the AWAC 600 khz is the optimal tool for medium water-depth current and wave measurements.

Highlights Applications Real-time current profiles and waves to 50 m range Acoustic surface tracking (AST) with vertical beam Can be used both with fixed frames and subsurface buoys Online measurements of currents and waves Design data for planning of new coastal structures Site studies for offshore wind platforms Coastal erosion studies Measurement campaigns where the full wave spectrum is needed Monitoring of transient waves for channel wall protection Studies of tidal currents

Technical specifications Water velocity measurements Maximum profiling range Cell size 50 m 0.5-8.0 m Number of cells Typical 20-40, max. 128 Velocity range Accuracy Velocity precision Maximum output rate Internal sampling rate ±10 m/s horizontal, ±5 m/s along beam ±1% of measured value ±0.5 cm/s Consult instrument software 1 Hz 4 Hz Echo intensity Sampling Resolution Dynamic range Transducer acoustic frequency Number of beams Same as velocity 0.45 db 90 db 600 khz 3 beams 120 apart, one vertical beam, (90 apart, one at 5 for platform mount) Beam width 3.1 Beam width vertical beam 1.7 Wave measurement option (AST) Maximum depth Data types Sampling rate velocity (output) Sampling rate AST (output) 60 m Pressure, one velocity along each beam, AST 1 Hz 2 Hz No. of samples per burst 512, 1024 or 2048

Wave estimates Range -15 to 15 m

Wave estimates Accuracy/resolution (Hs) < 1% of measured value / 1 cm Accuracy/resolution (Dir) 2 / 0.1 Period range Cut-off period (Hs) Cut-off period (dir) 1-50 s 5 m depth; 0.5 sec, 20 m depth; 0.9 sec, 60 m depth; 1.5 sec 5 m depth; 1.5 sec, 20 m depth; 3.1 sec, 60 m depth; 4.2 sec Sensors Temperature: Thermistor embedded in housing Temp. range -4 to +40 C Temp. accuracy/resolution 0.1 C/0.01 C Temp. time response Compass: < 5 min Magnetoresistive Accuracy/resolution 2 /0.1 for tilt < 15 Tilt: Liquid level Accuracy/resolution 0.2 /0.1 Maximum tilt Up or Down Pressure: Range Accuracy Resolution 30,AST requires < 10 instrument tilt Automatic detect Piezoresistive 100 m 0.5% of full scale (optional 0.1% of full scale) 0.005% of full scale Analog inputs No. of channels 2 Supply voltage to analog output devices Voltage input Resolution Three options selectable through firmware commands: 1) Battery voltage/500 ma, 2) +5 V/250 ma, 3) +12 V/100 ma 0-5 V 16-bit A/D

Data recording Capacity 9 MB standard, 4/16 GB (ProLog)

Data recording Profile record Wave record Mode Ncells*9 + 120 bytes Nsamples*24 + 1k bytes Stop when full (default and Prolog) or wrap mode Real-time clock Accuracy Backup in absence of power ±1 min/year 1 year Data communications I/O Communication baud rate Recorder download baud rate User control Output formats RS-232 or RS-422. Software supports most commercially available USB RS-232 converters 300-115200 Bd 600/1200 kbd for both RS-232 and RS-422 Handled via AWAC AST software, or ActiveX controls. Seastate for online systems NMEA, Binary. Prolog provides same types also for processed wave and current data Connectors Bulkhead (Impulse) Cable MCBH-2-FS, MCBH-8-FS, Souriau option PMCIL-8-MP on 10m polyurethane cable, Souriau option Software Functions Deployment planning, instrument configuration, data retrieval and conversion (for Windows ) Power DC input Maximum peak current Avg. power consumption Sleep current 9-18 V DC 3 A 0.76 W < 100 μa

Power Transmit Power 1-30W, 3 adjustable levels Environmental Operating temperature -4 to +40 C Storage temperature -20 to +60 C Shock and vibration IEC 721-3-2 EMC approval IEC 61000 Depth rating 300 m Materials Standard model POM and polyurethane plastics with titanium fasteners Dimensions Maximum diameter Maximum length 210 mm 203 mm Weight Weight in air Weight in water 6.2 kg 2.9 kg Online cable Polyurethane jacket, Shore D hardness, 13 mm in diameter, max 2 km. Inquire for longer cables